9
EMC VNX5500-F UNIFIED STORAGE FLASH ARRAY EMC® VNX5500-F™ unified storage all-flash array delivers uncompromising performance, availability, and flexibility for environments requiring the highest levels of transactional throughput. The EMC VNX5500-F is designed for five-9’s availability, a requirement for mission critical databases. Testing has shown the VNX5500-F delivers 10x the performance at 1/8th the transaction cost for both Oracle and Microsoft SQL OLTP workloads. Specifications ARCHITECTURE Based on the powerful new family of Intel Xeon-5600 processors, the EMC VNX5500-F implements a modular architecture that integrates hardware components for block, file, and object with concurrent support for native NAS, iSCSI, Fibre Channel, and FCoE protocols. The VNX5500-F delivers file (NAS) functionality via one-to-three X-blade data movers and block (iSCSI, FCoE, and FC) storage via dual storage processors leveraging full 6 Gb SAS connectivity to Flash drives. The unified configuration includes the following rack-mounted enclosures: Disk processor enclosure (holds disk drives) plus standby power system to deliver block protocols One or more data mover enclosures to deliver file protocols (optional) Control station (optional) PHYSICAL SPECIFICATIONS BLOCK COMPONENTS Min/Max Drives 25/250 Array Enclosure 3U Disk Processor Enclosure* with 21 x 2.5” 100 GB Flash drives or 21 x 2.5” 200 GB Flash drives Drive Enclosure Options (DAE) 25 x 2.5” SAS / Flash drives–2 U 15 x 3.5” SAS / Flash drives–3 U Standby Power System 1U 1.2KW Raid Options 0/1/10/3/5/6 CPU/Memory per Array Intel Xeon 5600 / 24 GB Max Block UltraFlex IO Modules per Array 4 Embedded IO Ports per Array 8 FC ports and 4 SAS ports (2 BE SAS buses)** SPECIFICATION SHEET

VNX Unified Specs

Embed Size (px)

DESCRIPTION

VNX Unified Specs

Citation preview

Page 1: VNX Unified Specs

EMC VNX5500-F UNIFIED STORAGE FLASH ARRAY

EMC® VNX5500-F™ unified storage all-flash array delivers uncompromising performance, availability, and flexibility for environments requiring the highest levels of transactional throughput. The EMC VNX5500-F is designed for five-9’s availability, a requirement for mission critical databases. Testing has shown the VNX5500-F delivers 10x the performance at 1/8th the transaction cost for both Oracle and Microsoft SQL OLTP workloads.

Specifications

ARCHITECTURE Based on the powerful new family of Intel Xeon-5600 processors, the EMC VNX5500-F implements a modular architecture that integrates hardware components for block, file, and object with concurrent support for native NAS, iSCSI, Fibre Channel, and FCoE protocols. The VNX5500-F delivers file (NAS) functionality via one-to-three X-blade data movers and block (iSCSI, FCoE, and FC) storage via dual storage processors leveraging full 6 Gb SAS connectivity to Flash drives.

The unified configuration includes the following rack-mounted enclosures:

• Disk processor enclosure (holds disk drives) plus standby power system to deliver block protocols

• One or more data mover enclosures to deliver file protocols (optional)

• Control station (optional)

PHYSICAL SPECIFICATIONS

BLOCK COMPONENTS

Min/Max Drives 25/250

Array Enclosure 3U Disk Processor Enclosure* with 21 x 2.5” 100 GB Flash drives or 21 x 2.5” 200 GB Flash drives

Drive Enclosure Options (DAE) 25 x 2.5” SAS / Flash drives–2 U

15 x 3.5” SAS / Flash drives–3 U

Standby Power System 1U 1.2KW

Raid Options 0/1/10/3/5/6

CPU/Memory per Array Intel Xeon 5600 / 24 GB

Max Block UltraFlex™ IO Modules per Array 4

Embedded IO Ports per Array 8 FC ports and 4 SAS ports (2 BE SAS buses)**

SPECIFICATION SHEET

Page 2: VNX Unified Specs

* * The disk processor enclosure also includes four SAS vault drives (300 GB 10K RPM) ** 4 embedded FC ports per array are reserved for file connectivity. *** The File components are not required when ordering a block-only system.

VNX CONNECTIVITY The VNX5500-Fs provides flexible connectivity options via UltraFlex IO modules for both the file X-blades for NAS connectivity and the block storage processors for FC and iSCSI host connectivity (see above table for number of modules supported per blade or SP).

Max Total Ports per Array 24

2/4/8 Gb/s FC Max Ports per Array 16

1 GBaseT iSCSI Max Total Ports per Array 16

10 GbE iSCSI Max Total Ports per Array 8

Max FCoE Total Ports per Array 8

6 Gb/s SAS Buses (4 Lanes per Bus) for DAE Connections

2

FILE COMPONENTS

# File X-Blades 1-3

# Control Stations 1-2 x 1U Server

X-Blade: CPU/Memory Intel Xeon 5600 / 12 GB

Max File UltraFlex IO Modules per X-Blade 4

Min/Max 2/4/8 Gb/s FC Ports per X-Blade 4

Max IP Ports per X-Blade 12

Max 1 GBaseT Ports per X-Blade 12

Max 10 GbE Ports per X-Blade 6

OTHER

Management LAN 2x 10/100/1000 Copper GbE

FUNCTIONAL LIMITS

Max Raw Capacity 679 TB

Max SAN Hosts 4,096

Max Number of Pools 40

Max Number of LUNs 4,096

Max LUN Size 16 TB (Virtual Pool LUN)

Max File System Size 16 TB

Maximum Usable File Capacity per X-Blade 256 TB

OS Support Block OS’s Plus File OS’s see E-Lab Navigator and NAS Support Matrix on Powerlink

ULTRAFLEX IO MODULE OPTIONS (BLOCK)

IO Module Description

Four-Port Fibre Channel Module

FC module with four ports auto-negotiating to 2/4/8 Gbps; uses optical SFP and OM2/OM3 cabling to connect directly to host HBA or FC switch

Page 3: VNX Unified Specs

MAXIMUM CABLE LENGTHS Shortwave optical OM2: 50 meters (8 Gb), 100 meters (4 Gb), and 300 meters (2 Gb)

Shortwave optical OM3: 150 meters (8 Gb), 380 meters (4 Gb), and 500 meters (2 Gb)

BACK-END (DISK) CONNECTIVITY Each storage processor connects to one side of each of two or six (four are optional) redundant pairs of four-lane x 6 Gb/s Serial Attached SCSI (SAS) buses, providing continuous drive access to hosts in the event of a storage processor or bus fault.

EXPANDABILITY VNX5500-F supports a maximum of 250 drives in up to 15 disk expansion chassis and can be expanded into a tiered storage system by adding disk array enclosures with any combination of Flash, SAS, and Near-line SAS drives.

Four-Port 1 Gb/s iSCSI Module with TOE

iSCSI module with four 1 GBaseT RJ-45 copper connections to Cat 6 cabling to Ethernet switch; includes TCP offload engine

Two-Port 10 Gb/s Opt iSCSI Module with TOE

iSCSI module with two 10 Gb/s Ethernet ports and choice of SFP+ optical connection or active twinax copper connection to Ethernet switch; includes TCP offload engine

Two-Port 10 GBaseT iSCSI Module with TOE

iSCSI module with two 10 GBaseT Ethernet ports with copper connection to Ethernet switch; includes TCP offload engine

Two-Port 10 GbE FCoE Module

FCoE module with two 10 Gb/s Ethernet ports and choice of SFP+ optical connection or active twinax copper connection to converged enhanced Ethernet switch

ULTRAFLEX IO MODULE OPTIONS (FILE)

IO Module Description

Four-Port 1 GBaseT IP Module

10/100/1000 BaseT module with four ports supporting RJ-45 copper connections to Cat 6 cabling to Ethernet switch

Four-Port 1 GBaseT and 1 GbE Opt IP Module

IP module with two ports of 10/100/1000 BaseT and two ports 1 GbE optical

Two-Port 10 GbE Opt IP Module

IP module with two 10 Gb/s Ethernet ports and choice of SFP+ optical connection or active twinax copper connection to Ethernet switch

Two-Port 10 GBaseT IP Module

IP module with two 10 GBaseT Ethernet ports with copper connection to Ethernet switch

Four-Port 8 Gb/s Fibre Channel Module

FC module with four ports auto-negotiating to 2/4/8 Gbps; uses optical SFP and OM2/OM3 cabling to connect directly to captive array and to provide NDMP tape connection

DISK ARRAY ENCLOSURES

25x2.5” Drive DAE 15x3.5” Drive DAE

Drive Types Supported 2.5” Flash 2.5” 10K Rotating

3.5” Flash 3.5” 15K Rotating 2.5” 10K Rotating (in 3.5” carrier) 3.5” Near-line Rotating

Drive Mixing No limitations No limitations

Controller Interface 6 Gb SAS 6 Gb SAS

Page 4: VNX Unified Specs

* Drive Options for Disk Processor Enclosure ** 520 bytes/sector, 1 MB = 1,048,576 bytes

DISK DRIVES FOR 25X2.5” DRIVE DISK PROCESSOR ENCLOSURE / DISKARRAY ENCLOSURE

Nominal Capacity

100 GB Solid State Drive*

200 GB Solid State Drive*

300 GB 10K Drive 600 GB 10K Drive 900 GB 10K Drive

Formatted Capacity**

93.1 GB 186.31 GB 272.59 GB 545.19 GB 833.4 GB

Form Factor 2.5” 2.5” 2.5” 2.5” 2.5”

Height 1.0” 1.0” 1.0” 1.0” 1.0”

Rotational Speed Solid State Solid State 10,000 rpm 10,000 rpm 10,000 rpm

Interface 6 Gb SAS 6 Gb SAS 6 Gb SAS 6 Gb SAS 6 Gb SAS

Data Buffer N/A SSD N/A SSD 16 MB min 16 MB min 16 MB min

ACCESS TIME

Average Read

N/A N/A 3.6 msec 3.6 msec 3.6 msec

Average Write N/A N/A 4.2 msec 4.2 msec 4.2 msec

Rotation Latency N/A N/A 3.0 msec 3.0 msec 3.0 msec

NOMINAL POWER CONSUMPTION (WATTS)

Operating Mode

4.97 4.97 6.15 5.6 5.6

Idle Mode 1.36 1.36 3.5 3.1 3.1

DISK DRIVES FOR 15X3.5” DRIVE DISK ARRAY ENCLOSURE

Nominal Capacity

100 GB Solid State Drive

200 GB Solid State Drive

300 GB 15K Drive

600 GB 15K Drive

300 GB 10K Drive

600 GB 10K Drive

900 GB 10K Drive

1 TB 7.2K Drive

2 TB 7.2K Drive

3 TB 7.2K Drive

Formatted Capacity*

93.1 GB

186.31 GB

272.59 GB

545.19 GB

272.59 GB

545.19 GB

833.4 GB

926.04 GB

1,852.09 GB

2794.5 GB

Drive Form Factor 3.5” 3.5” 3.5” 3.5” 2.5” 2.5” 2.5” 3.5” 3.5” 3.5”

Height 1.0” 1.0” 1.0” 1.0” 1.0” 1.0” 1.0” 1.0” 1.0” 1.0”

Rotational Speed

Solid State

Solid State

15,000 rpm

15,000 rpm

10,000 rpm

10,000 rpm

10,000 rpm

7,200 rpm 7,200 rpm 7,200 rpm

Interface 6 Gb SAS 6 Gb SAS 6 Gb SAS 6 Gb SAS 6 Gb SAS 6 Gb SAS 6 Gb SAS 6 Gb SAS 6 Gb SAS 6 Gb SAS

Data Buffer N/A SSD N/A SSD 16 MB min 16 MB min 16 MB min 16 MB min 16 MB min 16 MB min 16 MB min 16 MB min

ACCESS TIME

Average Read

N/A N/A 3.4 msec 3.4 msec 3.6 msec 3.7 msec 3.7 msec 8.5 msec 8.5 msec 8.5 msec

Average Write N/A N/A 3.9 msec 3.9 msec 4.2 msec 4.2 msec 4.2 msec 9.5 msec 9.5 msec 9.5 msec

Rotation Latency N/A N/A 2.0 msec 2.0 msec 3.0 msec 3.0 msec 3.0 msec 4.16 msec 4.16 msec 4.16 msec

NOMINAL POWER CONSUMPTION (WATTS)

Operating Mode

4.97 4.97 12.92 16.35 6.15 5.6 5.6 12.2 12.2 12.2

Idle Mode 1.36 1.36 8.74 11.68 3.5 3.1 3.1 8.0 8.0 8.0

Page 5: VNX Unified Specs

VNX5500-F OE PROTOCOLS AND SOFTWARE FACILITIES The VNX5500-F offers support for a wide variety of protocol and advanced features available via various software suites and packs.

PROTOCOLS AND FACILITIES SUPPORTED • Access-based Enumeration (ABE) for Microsoft Windows® Server 2003

• Address Resolution Protocol (ARP)

• Automated Volume Management (AVM): file system provisioning

• Block Protocols: iSCSI, Fibre Channel (FCP SCSI-3), and FCoE

• Common Criteria Certification: EAL 3+ Assurance Level

• DFS Distributed File System (Microsoft) as Leaf node or Root Server

• Ethernet Trunking

• File Protocols: NFSv2, v3, v4, and v4.1 with pNFS; CIFS (SMB 1 and SMB 2); FTP (including SFTP and FTPs)

• FileMover API: Open API for automated, transparent data movement between tiers of the storage network

• Lock Manager (NLM) v1, v3, and v4

• Failsafe Networking

• Internet Control Message Protocol (ICMP)

• Kerberos Authentication

• Lightweight Directory Access Protocol (LDAP)

• LDAP signing for Windows

• Link Aggregation (IEEE 802.3ad)

• UNIX archive utilities (tar/cpio)

• Network Data Management Protocol (NDMP) v1-v4

• Network Equipment-Building System (NEBS) Level 3/ETSI Certified

• Network Information Service (NIS) Client

• Network Status Monitor (NSM) v1

• Object support via EMC Atmos™ Virtual Edition

• Portmapper v2

• Network Time Protocol (NTP) client

• NT LAN Manager (NTLM)

• Restriction of Hazardous Substances (RoHS) compliance

• Routing Information Protocol (RIP) v1-v2

• Simple Network Management Protocol V1-V3 (SNMP)

• Simple Network Time Protocol (SNTP)

• Virtual Data Movers for Microsoft Windows clients

• Virtual LAN (IEEE 802.1q)

Page 6: VNX Unified Specs

VNX5500-F SOFTWARE Management Unisphere™ for Block,

Unisphere for File, or Unisphere for Unified

Protocols CIFS, NFS, pNFS, MPFS, FC, FCoE, iSCSI included

Base Software (included with VNX OE) File Single Instancing, Compression, and Virtual Provisioning

SOFTWARE SUITES

FAST Suite: Automatically optimize for the highest system performance and the lowest storage cost simultaneously

Dynamically tier data across drives

Extendable cache for performance boost

Trend analysis and reporting

Monitor and achieve performance objectives

Security and Compliance Suite: Keep data safe from changes, deletions, and malicious activity

Encrypt data where it is created

Disk-based WORM functionality

Anti-virus integration and alerting

Local Protection Suite: Practice Safe Data Protection and Repurposing

Block storage snaps and clones

Continuous Data Protection for DVR-like recovery for block storage

File system snaps

Remote Protection Suite: Protect data against localized failures, outages, and disasters

Unified storage replication with DVR-like recovery

Integrated WAN deduplication and bandwidth reduction

Granular file system level replication and recovery

Application Protection Suite: Automate application copies and prove compliance

Application copy management

Prove protection compliance

SOFTWARE PACKS

Protection Pack Local Protection Suite +

Remote Protection Suite +

Application Protection Suite

Total Efficiency Pack FAST Suite +

Security & Compliance Suite+

Local Protection Suite +

Remote Protection Suite +

Application Protection Suite

NOTE: For more detail on software licensing, please contact your sales representative.

OPTIONAL VMWARE FACILITIES AND TITLES The VNX series offers support for a wide variety of protocol and advanced features available via various software suites and packs.

• EMC Virtual Storage Integrator (VSI) for VMware® vSphere5: For provisioning, management, cloning, and deduplication

• Site Recovery Manager (SRM) Integration: Managing failover and failback making disaster recovery rapid and reliable

• Replication Manager: Host-based management of array-based copies of data

ADDITIONAL OPTIONAL EMC TITLES • EMC ProSphere®: VNX integration with EMC Storage management infrastructure

• EMC PowerPath®: path management

• EMC Cloud Tiering Appliance (CTA and CTA/VE): policy-based cloud tiering, file archiving, and migration

Page 7: VNX Unified Specs

VNX5500-F ELECTRICAL SPECIFICATIONS (For specific power specifications please refer to the EMC Power Calculator at power.emc.comwith your Powerlink account.)

DPE ENCLOSURE

POWER

AC Line Voltage 100 to 240 Vac± 10%, single-phase, 47 to 63 Hz

AC Line Current (operating maximum) 4.6 A max at 100 Vac, 2.3 A max at 200 Vac

Power Consumption (operating maximum) 460 VA (450 W) max

Power Factor 0.98 min at full load, low voltage

Heat Dissipation (operating maximum) 1.62 x 106 J/hr, (1,540 Btu/hr) max

In-rush Current 15 A max for ½ line cycle, per line cord at 240 Vac

8 A max for ½ line cycle, per line cord at 120 Vac

Startup Surge Current 29 A rms max for 50 ms, at any line voltage

AC Protection 12.5 A fuse on each power supply, both phases

AC Inlet Type IEC320-C14 appliance coupler, per power zone

Ride-through Time 30 ms min

Current Sharing ± 15 percent of full load, between power supplies

DIMENSIONS

Height (in/cm) 5.25 in / 13.34 cm

Width (in/cm) 17.5 in / 44.45 cm

Depth (in/cm) 24.25 in / 61.6 cm

Weight (lb/kg) (with and without drives)

Full: 75.25/34.2 Empty: 59.0/26.8

NOTE: Each DPE requires a Standby Power Supply (see the following information)

STANDBY POWER SUPPLY

POWER 1.2kW Standby Power Supply

AC Line Voltage 100 to 240 Vac ± 10%, single-phase, 47 to 63 Hz

AC Line Current, Internal and Pass-through

0.10 A max at 100 Vac, internal power consumption (Up to 10 A max at 100 Vac, pass-through to AC outlets) 0.05 A max at 200 Vac, internal power consumption (Up to 6 A max at 200 Vac, pass-through to AC outlets)

Internal Power Consumption 70 VA (40 W) pk in hi-charge mode, 10 VA (6 W) in float charge mode

Power Factor N/A for pass-through load, internal 10 VA load is 0.60 power factor

Heat Dissipation 21.6 x 103 J/hr, (20 Btu/hr) steady state

In-rush Current 9 A max for ½ line cycle, per power supply at 240 Vac

AC Protection 15 A fuse, both phases

AC Inlet Type IEC320-C14 appliance coupler with switch

AC Outlet Type IEC320-C13 appliance coupler, quantity two

Charge Times 190 minutes max

AC Failure Detect Time 10 ms max

Transfer Time 25 ms max

Dimensions (H/W/L) 1.6 in/17.5 in/23.75 in or4.0 cm/44.45 cm/60.3 cm

Weight 47 lb/21.6 Kg

Page 8: VNX Unified Specs

DATA MOVER ENCLOSURES, DISK ARRAY ENCLOSURES AND CONTROL STATION

VNX5500-F DME with (2) Data Movers

15x3.5” Disk Array Enclosure*

25x2.5” Disk Array Enclosure*

Control Station

AC Line Voltage 100 to 240 Vac± 10%, single-phase, 47 to 63 Hz

100 to 240 Vac± 10%, single-phase, 47 to 63 Hz

100 to 240 Vac± 10%, single-phase, 47 to 63 Hz

100 to 240 Vac± 10%, single-phase, 47 to 63 Hz

AC Line Current (operating maximum)

5.0 A max at 100 Vac, 2.5 A max at 200 Vac

2.8 A max at 100 Vac, 1.4 A max at 200 Vac

2.5 A max at 100 Vac, 1.3 A max at 200 Vac

1.0 A max at 100 Vac, 0.5 A max at 200 Vac

Power Consumption (operating maximum)

500 VA (470 W) max 280 VA (235 W) max 250 VA (230 W) max 132 VA (104 W) max

Power Factor 0.98 min at full load, low voltage

0.98 min at full load, low voltage

0.98 min at full load, low voltage

0.80 min at full load, low voltage

Heat Dissipation (operating maximum)

1.69 x 106 J/hr, (1,610 Btu/hr) max

8.46 x 105 J/hr, (800 Btu/hr) max

8.28 x 105 J/hr, (785 Btu/hr) max

3.60 x 105 J/hr, (300 Btu/hr) max

In-rush Current 15 A max for ½ line cycle, per line cord at 240 Vac

8 A max for ½ line cycle, per line cord at 120 Vac

50 A max for ½ line cycle, per line cord at 240 Vac

25 A max for ½ line cycle, per line cord at 120 Vac

50 A max for ½ line cycle, per line cord at 240 Vac

25 A max for ½ line cycle, per line cord at 120 Vac

15 A max for ½ line cycle, per line cord at 240 Vac

8 A max for ½ line cycle, per line cord at 120 Vac

Startup Surge Current 27 A rms max for 50 ms, at any line voltage

10.6 A rms max for 100 ms, at any line voltage

10.6 A rms max for 100 ms, at any line voltage

N/A

AC Protection 7.8 A fuse on each power supply, both phases

10 A fuse on each power supply, both phases

10 A fuse on each power supply, both phases

N/A

AC Inlet Type IEC320-C14 appliance coupler, per power zone

IEC320-C14 appliance coupler, per power zone

IEC320-C14 appliance coupler, per power zone

IEC320-C14 appliance coupler, per power zone

Ride-through Time 30 ms min 30 ms min 30 ms min N/A

Current Sharing ± 15 percent of full load, between power supplies

± 10 percent of full load, between power supplies

± 10 percent of full load, between power supplies

N/A

DIMENSIONS

Height (in/cm) 3.5 in/8.9 cm 5.25 in/13.34 cm 3.45 in/8.76 cm 1.75 in/4.45 cm

Width (in/cm) 17.5 in/44.45 cm 17.62 in/44.75 cm 17.62 in/44.75 cm 17.5 in/44.45 cm

Depth (in/cm) 24.25 in/61.6 cm 14 in/35.56 cm 13 in/33.02 cm 20 in/50.8 cm

Weight (lb/kg) (with and without drives)

52.5 lb/23.81 kg Full: 67/30.45 Empty: 32/14.5

Full: 38.35/17.4

Empty: 22.1/10.0

18 lb/8.16 kg

OPERATING ENVIRONMENT

40U CABINET

AC Line Voltage 200 to 240 Vac ± 10%, single-phase, 47 to 63 Hz

Power Configuration Two power domains (base and extended), each redundant

Power Inlet Count Either two (for redundant base configuration) or four (for redundant extended configuration)

Plug Types NEMA L6-30P or IEC309-332 P6 or IP57 (Australia)

Input Power Capacity 4,800 VA @ 200 Vac, 5,760 VA @ 240 Vac (base configuration)

9,600 VA @ 200 Vac, 11,520 VA @ 240 Vac (extended configuration)

AC Protection 30 A site circuit breakers on each power branch

40U Cabinet Dimensions Height - 75 in (190.8 cm); Width - 24.0 in (61.1 cm) Depth - 39.0 in (99.2 cm); Weight Empty – 380 lb (173 kg)

Page 9: VNX Unified Specs

ELECTROMAGNETIC EMISSIONS AND IMMUNITY FCC Class A EN55022 Class A CE Mark VCCI Class A (for Japan) ICES-003 Class A (for Canada) AS/NZS 3548 Class A (for Australia/New Zealand) EN55024 Immunity, ITE BSMI Class A (for Taiwan)

QUALITY AND SAFETY STANDARDS UL 60950; CSAC 22.2-60950, EN 60950 Manufactured under an ISO 9000-registered quality system ETSI EN 300 386

Temperature: 50–104 degrees F (10–40 degrees C)

Temperature Gradient: 18 degrees F/hr (10 degrees C/hr)

Relative Humidity: 20% to 80% (non-condensing

Altitude: 7,500 ft. (2,286.4 m) @ 104 degrees F (40 degrees C) max

10,000 ft (3,048 m) @ 98.6 degrees F (37 degrees C) max

EMC Corporation Hopkinton, Massachusetts 01748-9103 1-508-435-1000 In North America 1-866-464-7381 www.EMC.com

EMC2, EMC, the EMC logo, EMC Virtual Positioning, Atmos, E-Lab, ProSphere, PowerPath, Powerlink, Unisphere, UltraFlex, VNX, and VNX5500-F are registered trademarks or trademarks of EMC Corporation in the United States and other countries. VMware and the VMware logo are registered trademarks or trademarks of VMware, Inc., in the United States and other jurisdictions. © Copyright 2011, 2012 EMC Corporation. All rights reserved. Published in the USA. 07/12 Specification Sheet H8919.2 EMC believes the information in this document is accurate as of its publication date. The information is subject to change without notice.

CONTACT US To learn more about how EMC products, services, and solutions can help solve your business and IT challenges, contact your local representative or authorized reseller—or visit us at www.EMC.com.