EMC VNX5500-F UNIFIED STORAGE FLASH ARRAY
EMC® VNX5500-F™ unified storage all-flash array delivers uncompromising performance, availability, and flexibility for environments requiring the highest levels of transactional throughput. The EMC VNX5500-F is designed for five-9’s availability, a requirement for mission critical databases. Testing has shown the VNX5500-F delivers 10x the performance at 1/8th the transaction cost for both Oracle and Microsoft SQL OLTP workloads.
Specifications
ARCHITECTURE Based on the powerful new family of Intel Xeon-5600 processors, the EMC VNX5500-F implements a modular architecture that integrates hardware components for block, file, and object with concurrent support for native NAS, iSCSI, Fibre Channel, and FCoE protocols. The VNX5500-F delivers file (NAS) functionality via one-to-three X-blade data movers and block (iSCSI, FCoE, and FC) storage via dual storage processors leveraging full 6 Gb SAS connectivity to Flash drives.
The unified configuration includes the following rack-mounted enclosures:
• Disk processor enclosure (holds disk drives) plus standby power system to deliver block protocols
• One or more data mover enclosures to deliver file protocols (optional)
• Control station (optional)
PHYSICAL SPECIFICATIONS
BLOCK COMPONENTS
Min/Max Drives 25/250
Array Enclosure 3U Disk Processor Enclosure* with 21 x 2.5” 100 GB Flash drives or 21 x 2.5” 200 GB Flash drives
Drive Enclosure Options (DAE) 25 x 2.5” SAS / Flash drives–2 U
15 x 3.5” SAS / Flash drives–3 U
Standby Power System 1U 1.2KW
Raid Options 0/1/10/3/5/6
CPU/Memory per Array Intel Xeon 5600 / 24 GB
Max Block UltraFlex™ IO Modules per Array 4
Embedded IO Ports per Array 8 FC ports and 4 SAS ports (2 BE SAS buses)**
SPECIFICATION SHEET
* * The disk processor enclosure also includes four SAS vault drives (300 GB 10K RPM) ** 4 embedded FC ports per array are reserved for file connectivity. *** The File components are not required when ordering a block-only system.
VNX CONNECTIVITY The VNX5500-Fs provides flexible connectivity options via UltraFlex IO modules for both the file X-blades for NAS connectivity and the block storage processors for FC and iSCSI host connectivity (see above table for number of modules supported per blade or SP).
Max Total Ports per Array 24
2/4/8 Gb/s FC Max Ports per Array 16
1 GBaseT iSCSI Max Total Ports per Array 16
10 GbE iSCSI Max Total Ports per Array 8
Max FCoE Total Ports per Array 8
6 Gb/s SAS Buses (4 Lanes per Bus) for DAE Connections
2
FILE COMPONENTS
# File X-Blades 1-3
# Control Stations 1-2 x 1U Server
X-Blade: CPU/Memory Intel Xeon 5600 / 12 GB
Max File UltraFlex IO Modules per X-Blade 4
Min/Max 2/4/8 Gb/s FC Ports per X-Blade 4
Max IP Ports per X-Blade 12
Max 1 GBaseT Ports per X-Blade 12
Max 10 GbE Ports per X-Blade 6
OTHER
Management LAN 2x 10/100/1000 Copper GbE
FUNCTIONAL LIMITS
Max Raw Capacity 679 TB
Max SAN Hosts 4,096
Max Number of Pools 40
Max Number of LUNs 4,096
Max LUN Size 16 TB (Virtual Pool LUN)
Max File System Size 16 TB
Maximum Usable File Capacity per X-Blade 256 TB
OS Support Block OS’s Plus File OS’s see E-Lab Navigator and NAS Support Matrix on Powerlink
ULTRAFLEX IO MODULE OPTIONS (BLOCK)
IO Module Description
Four-Port Fibre Channel Module
FC module with four ports auto-negotiating to 2/4/8 Gbps; uses optical SFP and OM2/OM3 cabling to connect directly to host HBA or FC switch
MAXIMUM CABLE LENGTHS Shortwave optical OM2: 50 meters (8 Gb), 100 meters (4 Gb), and 300 meters (2 Gb)
Shortwave optical OM3: 150 meters (8 Gb), 380 meters (4 Gb), and 500 meters (2 Gb)
BACK-END (DISK) CONNECTIVITY Each storage processor connects to one side of each of two or six (four are optional) redundant pairs of four-lane x 6 Gb/s Serial Attached SCSI (SAS) buses, providing continuous drive access to hosts in the event of a storage processor or bus fault.
EXPANDABILITY VNX5500-F supports a maximum of 250 drives in up to 15 disk expansion chassis and can be expanded into a tiered storage system by adding disk array enclosures with any combination of Flash, SAS, and Near-line SAS drives.
Four-Port 1 Gb/s iSCSI Module with TOE
iSCSI module with four 1 GBaseT RJ-45 copper connections to Cat 6 cabling to Ethernet switch; includes TCP offload engine
Two-Port 10 Gb/s Opt iSCSI Module with TOE
iSCSI module with two 10 Gb/s Ethernet ports and choice of SFP+ optical connection or active twinax copper connection to Ethernet switch; includes TCP offload engine
Two-Port 10 GBaseT iSCSI Module with TOE
iSCSI module with two 10 GBaseT Ethernet ports with copper connection to Ethernet switch; includes TCP offload engine
Two-Port 10 GbE FCoE Module
FCoE module with two 10 Gb/s Ethernet ports and choice of SFP+ optical connection or active twinax copper connection to converged enhanced Ethernet switch
ULTRAFLEX IO MODULE OPTIONS (FILE)
IO Module Description
Four-Port 1 GBaseT IP Module
10/100/1000 BaseT module with four ports supporting RJ-45 copper connections to Cat 6 cabling to Ethernet switch
Four-Port 1 GBaseT and 1 GbE Opt IP Module
IP module with two ports of 10/100/1000 BaseT and two ports 1 GbE optical
Two-Port 10 GbE Opt IP Module
IP module with two 10 Gb/s Ethernet ports and choice of SFP+ optical connection or active twinax copper connection to Ethernet switch
Two-Port 10 GBaseT IP Module
IP module with two 10 GBaseT Ethernet ports with copper connection to Ethernet switch
Four-Port 8 Gb/s Fibre Channel Module
FC module with four ports auto-negotiating to 2/4/8 Gbps; uses optical SFP and OM2/OM3 cabling to connect directly to captive array and to provide NDMP tape connection
DISK ARRAY ENCLOSURES
25x2.5” Drive DAE 15x3.5” Drive DAE
Drive Types Supported 2.5” Flash 2.5” 10K Rotating
3.5” Flash 3.5” 15K Rotating 2.5” 10K Rotating (in 3.5” carrier) 3.5” Near-line Rotating
Drive Mixing No limitations No limitations
Controller Interface 6 Gb SAS 6 Gb SAS
* Drive Options for Disk Processor Enclosure ** 520 bytes/sector, 1 MB = 1,048,576 bytes
DISK DRIVES FOR 25X2.5” DRIVE DISK PROCESSOR ENCLOSURE / DISKARRAY ENCLOSURE
Nominal Capacity
100 GB Solid State Drive*
200 GB Solid State Drive*
300 GB 10K Drive 600 GB 10K Drive 900 GB 10K Drive
Formatted Capacity**
93.1 GB 186.31 GB 272.59 GB 545.19 GB 833.4 GB
Form Factor 2.5” 2.5” 2.5” 2.5” 2.5”
Height 1.0” 1.0” 1.0” 1.0” 1.0”
Rotational Speed Solid State Solid State 10,000 rpm 10,000 rpm 10,000 rpm
Interface 6 Gb SAS 6 Gb SAS 6 Gb SAS 6 Gb SAS 6 Gb SAS
Data Buffer N/A SSD N/A SSD 16 MB min 16 MB min 16 MB min
ACCESS TIME
Average Read
N/A N/A 3.6 msec 3.6 msec 3.6 msec
Average Write N/A N/A 4.2 msec 4.2 msec 4.2 msec
Rotation Latency N/A N/A 3.0 msec 3.0 msec 3.0 msec
NOMINAL POWER CONSUMPTION (WATTS)
Operating Mode
4.97 4.97 6.15 5.6 5.6
Idle Mode 1.36 1.36 3.5 3.1 3.1
DISK DRIVES FOR 15X3.5” DRIVE DISK ARRAY ENCLOSURE
Nominal Capacity
100 GB Solid State Drive
200 GB Solid State Drive
300 GB 15K Drive
600 GB 15K Drive
300 GB 10K Drive
600 GB 10K Drive
900 GB 10K Drive
1 TB 7.2K Drive
2 TB 7.2K Drive
3 TB 7.2K Drive
Formatted Capacity*
93.1 GB
186.31 GB
272.59 GB
545.19 GB
272.59 GB
545.19 GB
833.4 GB
926.04 GB
1,852.09 GB
2794.5 GB
Drive Form Factor 3.5” 3.5” 3.5” 3.5” 2.5” 2.5” 2.5” 3.5” 3.5” 3.5”
Height 1.0” 1.0” 1.0” 1.0” 1.0” 1.0” 1.0” 1.0” 1.0” 1.0”
Rotational Speed
Solid State
Solid State
15,000 rpm
15,000 rpm
10,000 rpm
10,000 rpm
10,000 rpm
7,200 rpm 7,200 rpm 7,200 rpm
Interface 6 Gb SAS 6 Gb SAS 6 Gb SAS 6 Gb SAS 6 Gb SAS 6 Gb SAS 6 Gb SAS 6 Gb SAS 6 Gb SAS 6 Gb SAS
Data Buffer N/A SSD N/A SSD 16 MB min 16 MB min 16 MB min 16 MB min 16 MB min 16 MB min 16 MB min 16 MB min
ACCESS TIME
Average Read
N/A N/A 3.4 msec 3.4 msec 3.6 msec 3.7 msec 3.7 msec 8.5 msec 8.5 msec 8.5 msec
Average Write N/A N/A 3.9 msec 3.9 msec 4.2 msec 4.2 msec 4.2 msec 9.5 msec 9.5 msec 9.5 msec
Rotation Latency N/A N/A 2.0 msec 2.0 msec 3.0 msec 3.0 msec 3.0 msec 4.16 msec 4.16 msec 4.16 msec
NOMINAL POWER CONSUMPTION (WATTS)
Operating Mode
4.97 4.97 12.92 16.35 6.15 5.6 5.6 12.2 12.2 12.2
Idle Mode 1.36 1.36 8.74 11.68 3.5 3.1 3.1 8.0 8.0 8.0
VNX5500-F OE PROTOCOLS AND SOFTWARE FACILITIES The VNX5500-F offers support for a wide variety of protocol and advanced features available via various software suites and packs.
PROTOCOLS AND FACILITIES SUPPORTED • Access-based Enumeration (ABE) for Microsoft Windows® Server 2003
• Address Resolution Protocol (ARP)
• Automated Volume Management (AVM): file system provisioning
• Block Protocols: iSCSI, Fibre Channel (FCP SCSI-3), and FCoE
• Common Criteria Certification: EAL 3+ Assurance Level
• DFS Distributed File System (Microsoft) as Leaf node or Root Server
• Ethernet Trunking
• File Protocols: NFSv2, v3, v4, and v4.1 with pNFS; CIFS (SMB 1 and SMB 2); FTP (including SFTP and FTPs)
• FileMover API: Open API for automated, transparent data movement between tiers of the storage network
• Lock Manager (NLM) v1, v3, and v4
• Failsafe Networking
• Internet Control Message Protocol (ICMP)
• Kerberos Authentication
• Lightweight Directory Access Protocol (LDAP)
• LDAP signing for Windows
• Link Aggregation (IEEE 802.3ad)
• UNIX archive utilities (tar/cpio)
• Network Data Management Protocol (NDMP) v1-v4
• Network Equipment-Building System (NEBS) Level 3/ETSI Certified
• Network Information Service (NIS) Client
• Network Status Monitor (NSM) v1
• Object support via EMC Atmos™ Virtual Edition
• Portmapper v2
• Network Time Protocol (NTP) client
• NT LAN Manager (NTLM)
• Restriction of Hazardous Substances (RoHS) compliance
• Routing Information Protocol (RIP) v1-v2
• Simple Network Management Protocol V1-V3 (SNMP)
• Simple Network Time Protocol (SNTP)
• Virtual Data Movers for Microsoft Windows clients
• Virtual LAN (IEEE 802.1q)
VNX5500-F SOFTWARE Management Unisphere™ for Block,
Unisphere for File, or Unisphere for Unified
Protocols CIFS, NFS, pNFS, MPFS, FC, FCoE, iSCSI included
Base Software (included with VNX OE) File Single Instancing, Compression, and Virtual Provisioning
SOFTWARE SUITES
FAST Suite: Automatically optimize for the highest system performance and the lowest storage cost simultaneously
Dynamically tier data across drives
Extendable cache for performance boost
Trend analysis and reporting
Monitor and achieve performance objectives
Security and Compliance Suite: Keep data safe from changes, deletions, and malicious activity
Encrypt data where it is created
Disk-based WORM functionality
Anti-virus integration and alerting
Local Protection Suite: Practice Safe Data Protection and Repurposing
Block storage snaps and clones
Continuous Data Protection for DVR-like recovery for block storage
File system snaps
Remote Protection Suite: Protect data against localized failures, outages, and disasters
Unified storage replication with DVR-like recovery
Integrated WAN deduplication and bandwidth reduction
Granular file system level replication and recovery
Application Protection Suite: Automate application copies and prove compliance
Application copy management
Prove protection compliance
SOFTWARE PACKS
Protection Pack Local Protection Suite +
Remote Protection Suite +
Application Protection Suite
Total Efficiency Pack FAST Suite +
Security & Compliance Suite+
Local Protection Suite +
Remote Protection Suite +
Application Protection Suite
NOTE: For more detail on software licensing, please contact your sales representative.
OPTIONAL VMWARE FACILITIES AND TITLES The VNX series offers support for a wide variety of protocol and advanced features available via various software suites and packs.
• EMC Virtual Storage Integrator (VSI) for VMware® vSphere5: For provisioning, management, cloning, and deduplication
• Site Recovery Manager (SRM) Integration: Managing failover and failback making disaster recovery rapid and reliable
• Replication Manager: Host-based management of array-based copies of data
ADDITIONAL OPTIONAL EMC TITLES • EMC ProSphere®: VNX integration with EMC Storage management infrastructure
• EMC PowerPath®: path management
• EMC Cloud Tiering Appliance (CTA and CTA/VE): policy-based cloud tiering, file archiving, and migration
VNX5500-F ELECTRICAL SPECIFICATIONS (For specific power specifications please refer to the EMC Power Calculator at power.emc.comwith your Powerlink account.)
DPE ENCLOSURE
POWER
AC Line Voltage 100 to 240 Vac± 10%, single-phase, 47 to 63 Hz
AC Line Current (operating maximum) 4.6 A max at 100 Vac, 2.3 A max at 200 Vac
Power Consumption (operating maximum) 460 VA (450 W) max
Power Factor 0.98 min at full load, low voltage
Heat Dissipation (operating maximum) 1.62 x 106 J/hr, (1,540 Btu/hr) max
In-rush Current 15 A max for ½ line cycle, per line cord at 240 Vac
8 A max for ½ line cycle, per line cord at 120 Vac
Startup Surge Current 29 A rms max for 50 ms, at any line voltage
AC Protection 12.5 A fuse on each power supply, both phases
AC Inlet Type IEC320-C14 appliance coupler, per power zone
Ride-through Time 30 ms min
Current Sharing ± 15 percent of full load, between power supplies
DIMENSIONS
Height (in/cm) 5.25 in / 13.34 cm
Width (in/cm) 17.5 in / 44.45 cm
Depth (in/cm) 24.25 in / 61.6 cm
Weight (lb/kg) (with and without drives)
Full: 75.25/34.2 Empty: 59.0/26.8
NOTE: Each DPE requires a Standby Power Supply (see the following information)
STANDBY POWER SUPPLY
POWER 1.2kW Standby Power Supply
AC Line Voltage 100 to 240 Vac ± 10%, single-phase, 47 to 63 Hz
AC Line Current, Internal and Pass-through
0.10 A max at 100 Vac, internal power consumption (Up to 10 A max at 100 Vac, pass-through to AC outlets) 0.05 A max at 200 Vac, internal power consumption (Up to 6 A max at 200 Vac, pass-through to AC outlets)
Internal Power Consumption 70 VA (40 W) pk in hi-charge mode, 10 VA (6 W) in float charge mode
Power Factor N/A for pass-through load, internal 10 VA load is 0.60 power factor
Heat Dissipation 21.6 x 103 J/hr, (20 Btu/hr) steady state
In-rush Current 9 A max for ½ line cycle, per power supply at 240 Vac
AC Protection 15 A fuse, both phases
AC Inlet Type IEC320-C14 appliance coupler with switch
AC Outlet Type IEC320-C13 appliance coupler, quantity two
Charge Times 190 minutes max
AC Failure Detect Time 10 ms max
Transfer Time 25 ms max
Dimensions (H/W/L) 1.6 in/17.5 in/23.75 in or4.0 cm/44.45 cm/60.3 cm
Weight 47 lb/21.6 Kg
DATA MOVER ENCLOSURES, DISK ARRAY ENCLOSURES AND CONTROL STATION
VNX5500-F DME with (2) Data Movers
15x3.5” Disk Array Enclosure*
25x2.5” Disk Array Enclosure*
Control Station
AC Line Voltage 100 to 240 Vac± 10%, single-phase, 47 to 63 Hz
100 to 240 Vac± 10%, single-phase, 47 to 63 Hz
100 to 240 Vac± 10%, single-phase, 47 to 63 Hz
100 to 240 Vac± 10%, single-phase, 47 to 63 Hz
AC Line Current (operating maximum)
5.0 A max at 100 Vac, 2.5 A max at 200 Vac
2.8 A max at 100 Vac, 1.4 A max at 200 Vac
2.5 A max at 100 Vac, 1.3 A max at 200 Vac
1.0 A max at 100 Vac, 0.5 A max at 200 Vac
Power Consumption (operating maximum)
500 VA (470 W) max 280 VA (235 W) max 250 VA (230 W) max 132 VA (104 W) max
Power Factor 0.98 min at full load, low voltage
0.98 min at full load, low voltage
0.98 min at full load, low voltage
0.80 min at full load, low voltage
Heat Dissipation (operating maximum)
1.69 x 106 J/hr, (1,610 Btu/hr) max
8.46 x 105 J/hr, (800 Btu/hr) max
8.28 x 105 J/hr, (785 Btu/hr) max
3.60 x 105 J/hr, (300 Btu/hr) max
In-rush Current 15 A max for ½ line cycle, per line cord at 240 Vac
8 A max for ½ line cycle, per line cord at 120 Vac
50 A max for ½ line cycle, per line cord at 240 Vac
25 A max for ½ line cycle, per line cord at 120 Vac
50 A max for ½ line cycle, per line cord at 240 Vac
25 A max for ½ line cycle, per line cord at 120 Vac
15 A max for ½ line cycle, per line cord at 240 Vac
8 A max for ½ line cycle, per line cord at 120 Vac
Startup Surge Current 27 A rms max for 50 ms, at any line voltage
10.6 A rms max for 100 ms, at any line voltage
10.6 A rms max for 100 ms, at any line voltage
N/A
AC Protection 7.8 A fuse on each power supply, both phases
10 A fuse on each power supply, both phases
10 A fuse on each power supply, both phases
N/A
AC Inlet Type IEC320-C14 appliance coupler, per power zone
IEC320-C14 appliance coupler, per power zone
IEC320-C14 appliance coupler, per power zone
IEC320-C14 appliance coupler, per power zone
Ride-through Time 30 ms min 30 ms min 30 ms min N/A
Current Sharing ± 15 percent of full load, between power supplies
± 10 percent of full load, between power supplies
± 10 percent of full load, between power supplies
N/A
DIMENSIONS
Height (in/cm) 3.5 in/8.9 cm 5.25 in/13.34 cm 3.45 in/8.76 cm 1.75 in/4.45 cm
Width (in/cm) 17.5 in/44.45 cm 17.62 in/44.75 cm 17.62 in/44.75 cm 17.5 in/44.45 cm
Depth (in/cm) 24.25 in/61.6 cm 14 in/35.56 cm 13 in/33.02 cm 20 in/50.8 cm
Weight (lb/kg) (with and without drives)
52.5 lb/23.81 kg Full: 67/30.45 Empty: 32/14.5
Full: 38.35/17.4
Empty: 22.1/10.0
18 lb/8.16 kg
OPERATING ENVIRONMENT
40U CABINET
AC Line Voltage 200 to 240 Vac ± 10%, single-phase, 47 to 63 Hz
Power Configuration Two power domains (base and extended), each redundant
Power Inlet Count Either two (for redundant base configuration) or four (for redundant extended configuration)
Plug Types NEMA L6-30P or IEC309-332 P6 or IP57 (Australia)
Input Power Capacity 4,800 VA @ 200 Vac, 5,760 VA @ 240 Vac (base configuration)
9,600 VA @ 200 Vac, 11,520 VA @ 240 Vac (extended configuration)
AC Protection 30 A site circuit breakers on each power branch
40U Cabinet Dimensions Height - 75 in (190.8 cm); Width - 24.0 in (61.1 cm) Depth - 39.0 in (99.2 cm); Weight Empty – 380 lb (173 kg)
ELECTROMAGNETIC EMISSIONS AND IMMUNITY FCC Class A EN55022 Class A CE Mark VCCI Class A (for Japan) ICES-003 Class A (for Canada) AS/NZS 3548 Class A (for Australia/New Zealand) EN55024 Immunity, ITE BSMI Class A (for Taiwan)
QUALITY AND SAFETY STANDARDS UL 60950; CSAC 22.2-60950, EN 60950 Manufactured under an ISO 9000-registered quality system ETSI EN 300 386
Temperature: 50–104 degrees F (10–40 degrees C)
Temperature Gradient: 18 degrees F/hr (10 degrees C/hr)
Relative Humidity: 20% to 80% (non-condensing
Altitude: 7,500 ft. (2,286.4 m) @ 104 degrees F (40 degrees C) max
10,000 ft (3,048 m) @ 98.6 degrees F (37 degrees C) max
EMC Corporation Hopkinton, Massachusetts 01748-9103 1-508-435-1000 In North America 1-866-464-7381 www.EMC.com
EMC2, EMC, the EMC logo, EMC Virtual Positioning, Atmos, E-Lab, ProSphere, PowerPath, Powerlink, Unisphere, UltraFlex, VNX, and VNX5500-F are registered trademarks or trademarks of EMC Corporation in the United States and other countries. VMware and the VMware logo are registered trademarks or trademarks of VMware, Inc., in the United States and other jurisdictions. © Copyright 2011, 2012 EMC Corporation. All rights reserved. Published in the USA. 07/12 Specification Sheet H8919.2 EMC believes the information in this document is accurate as of its publication date. The information is subject to change without notice.
CONTACT US To learn more about how EMC products, services, and solutions can help solve your business and IT challenges, contact your local representative or authorized reseller—or visit us at www.EMC.com.