Vol II (ICAR Audi Interior 2013)

Embed Size (px)

Citation preview

  • 7/24/2019 Vol II (ICAR Audi Interior 2013)

    1/50

    INDIAN COUNCIL OF AGRICULTURAL

    RESEARCH, NEW DELHI

    TENDER AND CONTRACT DOCUMENT

    Name of Work: Interior works including civil, electrical, acoustics etc. for

    Auditorium at NASC Complex, Pusa, New Delhi.

    TENDER NO.: RITES/CP/ICAR/Audi/Interior/2013

    PART 2: FINANCIAL BID

    August, 2013

    (AGOVT.OFINDIAENTERPRISE)

    RITESLIMITED

    RITESBHAWANIIPLOTNO.144

    SECTOR44Gurgaon122003,india

    Tel(0124)2728305,fax(0124)2728371

  • 7/24/2019 Vol II (ICAR Audi Interior 2013)

    2/50

    B SUB TOTAL OF ELECTRICAL WORKS (B)

    GRAND TOTAL (A + B)

    UNCONDITIONAL REBATE(IF ANY)

    TOTAL OF ALL SCHEDULES

    AFTER APPLYING REBATE

    (RUPEES)

    (i) In figures

    (ii) In words.

    i) SIGNATURE OF AUTHORIZED SIGNATORY OF TENDERER

    ii) NAME OF SIGNATORY

    iii) NAME AND SEAL OF TENDERER

    iv) DATE

    A SUB TOTAL OF CIVIL WORKS:

    PART -II

    FINANCIAL BID

    SCHEDULE (BILL) OF QUANTITIES

    Name of Work: Interior works including civil, electrical, acoustics etc. for Auditorium atNASC Complex, Pusa, New Delhi.

    SUMMARY

    S. NO. Description Amount (in fig) Amount (in words)

  • 7/24/2019 Vol II (ICAR Audi Interior 2013)

    3/50

    S.N. DESCRIPTION OF ITEM UNIT QTY AMOUNT in figu

    (Rs.)

    in figures in words

    1.00 FLOORING

    Note:

    Wastage will not be payable extra in any of items.

    Measurement of finished portion will be taken for

    a ment.

    Granite Flooring

    1.01 Providing and laying 18 mm thick mirror finished

    granite stone flooring, machine cut in required

    size, approved shade, color and texture laid using

    white cement slurry over 20 mm (average) thick

    base of cement mortar 1:4 (1 cement : 4 coarse

    sand) followed by laying, fixing and jointed with

    white cement slurry mixed with matching pigment,

    including rubbing and curing moulding and

    polishing to edge to give high gloss finish etc

    complete at all levels.(as approved)

    1.01.1 Granite Type-A with Basic Rate 195/- sft FOR site Sqm. 2,342.00

    1.01.2 Granite Type-B with Basic Rate 170/- sft FOR site Sqm. 586.00

    1.02 Providing and fixing 18mm thick gang saw cut

    mirror polished (premoulded and prepolished)

    machine cut in risers of steps, skirting, dado and

    pillars of approved shade, color and texture (as

    approved) laid on 12 mm (average) thick cement

    mortar 1:3 (1 cement 3 coarse sand) with joints

    treated with white cement, mixed with matching

    pigment, epoxy touch ups, including rubbing,

    curing moulding and polishing to edge, if required

    to give high gloss finish etc. complete at all levels

    and as per direction of E-I-C.

    1.02.1 Granite Type-A with Basic Rate 195/- sft FOR site Sqm. 953.00

    1.02.2 Granite Type-B with Basic Rate 170/- sft FOR site Sqm. 238.00

    Italian Marble Flooring, Skirting & Dado

    1.03 Providing and fixing Italian marble in flooring,

    skirting, wall dado etc as approved using 18mm

    thick gang saw machine cut stone at all levels, of

    required size & pattern and of approved shade,

    color and texture laid using white cement slurry

    over 20 mm thick base of cement mortar 1:4 (1

    cement : 4 coarse sand) followed by laying, fixing

    and jointing with white cement slurry mixed withmatching pigment, including rubbing, curing,

    polishing, making mouldings of approved profile

    and polishing of mouldings and edges to give high

    gloss finish etc, complete at all levels and as per

    direction of E-I-C.

    1.03.1 Italian Marble Type-A (Light Emperador), Type-B

    (Bottochino) & Type-C (Spanish Grey) in flooring

    with Basic Rate Upto 250/- sft FOR site

    Sqm. 1,343.00

    BILL OF QUANTITIES

    RATE (in Rs.)

    NAME OF WORK:Interior works including civil, electrical, acoustics etc. for Auditorium at NASC Complex, Pusa, New Delhi

  • 7/24/2019 Vol II (ICAR Audi Interior 2013)

    4/50

    S.N. DESCRIPTION OF ITEM UNIT QTY AMOUNT in figu

    (Rs.)

    in figures in words

    RATE (in Rs.)

    1.03.2 Italian Marble Type-D (Dark Emperador), Type-E

    (Perlato Sicilia) & Type-F (Grey William) in floor

    with basic rate Upto Rs.340/- sft FOR Site

    Sqm. 576.00

    1.03.3 Italian Marble Type-A (Light Emperador), Type-B

    (Bottochino) & Type-C (Spanish Grey) indado/wall with Basic Rate Upto 250/- sft FOR site

    Sqm. 218.00

    1.03.4 Italian Marble Type-D (Dark Emperador), Type-E

    (Perlato Sicilia) & Type-F (Grey William) in

    dado/wall with Basic Rate Upto 340/- sft FOR

    site.

    Sqm. 24.00

    Composite/Engineered Marble Stone Counters

    1.04 Providing and fixing 20 mm thick gang saw cut

    mirror polished (premoulded and prepolished)

    machine cut Composite/Engineered marble stone

    for kitchen platforms, vanity counters ,window

    sills, facias, skirting and similar locations ofrequired size of approved shade, color and texture

    (as per approved sample) including laying by

    using white cement slurry laid over 20mm thick

    base of cement mortar 1:4 (1 cement : 4 coarse

    sand) followed by all side joints treated with white

    cement, mixed with matching pigment, epoxy

    touch ups, including rubbing, curing, making

    moulding and polishing to edge to give high gloss

    finish etc. complete at all levels and as per

    direction of E-I-C.

    1.04.1 Composite Marble Type-A Sqm. 212.00

    1.04.2 Composite Marble Type-B Sqm. 95.00

    1.04.3 Composite Marble Type-C Sqm. 95.00

    Vitrified & Ceramic Tile work

    1.05 Providing and laying anti skid Ceramic floor tiles

    600 x 600mm of minimum 9 mm thickness of 1st

    quality of approved make in all colors, shades as

    approved laid on 20mm thick cement mortar 1:4

    (1 cement:4 coarse sand) fixed with "+" shaped 2

    mm wide plastic spacers at corners (to be removed

    before jointing) to achieve a perfectly straight joint

    line, and jointed with Laticrete or approved

    equivalent jointing compound of matching shade

    complete as per direction of E-I-C.

    Sqm. 868.00

    1.06 Providing and laying vitrified floor tiles in

    different sizes (thickness to be specified by the

    manufacturer) with water absorption less than

    0.08% and conforming to IS : 15622, of approved

    make, in all colors and shades, laid on 20mm thick

    cement mortar 1:4 (1 cement : 4 coarse sand),

    including grouting the joints with white cement

    and matching pigments etc., complete & as per

    - -1.06.1 Size of Tile 600x600 mm Sqm. 390.00

  • 7/24/2019 Vol II (ICAR Audi Interior 2013)

    5/50

    S.N. DESCRIPTION OF ITEM UNIT QTY AMOUNT in figu

    (Rs.)

    in figures in words

    RATE (in Rs.)

    1.06.2 Extra for using "+" shaped 2 mm wide plastic

    spacers at corners (to be removed before jointing)

    during fixing of Vitrified tile in floor to achieve a

    perfectly straight joint line, and jointed with

    Laticrete or approved equivalent jointing

    compound of matching shade in place of white

    cement with matching pigment all complete as per - -

    Sqm. 390.00

    Wooden flooring

    1.07 Providing and fixing minimum 11mm thick AC VI

    grade laminated wooden flooring suitable for

    commercial-heavy use areas like auditorium

    application of approved make, shade and pattern.

    The top surface shall have a 0.60 mm thick multi

    layer high pressure laminate fixed over moisture

    resistant high density fiberboard substrate. The

    planks shall be of size 1200 mm x 200/125 mm.

    The flooring shall confirm to EN 438, EN 717-1,

    EN 13501-1, EN-1815, JIS Z 2801:2000

    standards. The planks shall be placed on an

    underlay of 0.2 mm thick alkali resistantPolyethylene sheet having density 920-935 kg/ m3

    to resist moisture from the sub floor and to secure

    the floor installation etc all complete. (Skirting

    profiles, trims etc shall be included & not paid

    extra) as per direction of E-I-C.

    Sqm. 407.00

    1.08 Providing and fixing 2090x205x30 mm thick

    Activity plank flooring jointed with tongue and

    groove joint having tensile strength of not less than

    10 kg/sqm. Top layer consisting of woodloc (15

    mm thick) supported on 6 mm HDF support

    element & base of 9 mm thick foam

    polytherne/polyether resilience element. Surface to

    be treated with pre-lacquered with UV-curedpolyurethene/acrylic based lacquer free from

    solvent & formaldehyde. Base of the floor consists

    of two layers of 12mm thick water proof marine

    ply, plywood bonded with phenolic resin with half

    headless GI nails/steel screws wherever necessary,

    with joints staggered with 2nd layer glued and

    screwed to the first, fixed with wooden screws to

    teakwood joists framework comprising 75x50mm

    teakwood joist 900mm C/C in one direction and

    50x50mm teak wood battens 400mm C/C on other

    direction, teakwood joists resiliently supported on

    150 x 150mm pads of 7.5mm nominal thickness of

    waffle, neoprene pad ribbed (50 p.s.i. grade) and

    50x50x6mm thick MS angle cleat fixed with

    150mm long with 10mm dia GI bolts andexpansion fasteners, over floor slab at 900 x 900

    Sqm. 341.00

    Support locations including providing and

    applying a coat of ready mixed aluminum primer

    and a coat of synthetic enamel paint both of

    approved brand and manufacturer over exposed

    surfaces and edges of marine ply. The item

    includes providing and fixing 145x50 mm

    teakwood moulding as approved on the edges of

    stage wooden flooring. Entire work shall be done

    complete as per drawings, specifications and

    directions of E-I-C. (Note : All teakwood shall be

    certified kiln seasoned and treated against

  • 7/24/2019 Vol II (ICAR Audi Interior 2013)

    6/50

    S.N. DESCRIPTION OF ITEM UNIT QTY AMOUNT in figu

    (Rs.)

    in figures in words

    RATE (in Rs.)

    1.09 Providing & laying at site finished Bamboo

    flooring (coffee shade) of approved make, color,

    shade & finish of minimum 12 mm thickness and

    of minimum size 960mm x 96 mm. The material

    shall fulfill the following standards : Flammability

    as per ASTM-E648 with Class-1 rating as per

    NFPA, Smoke density as per ASTM-E622 shall be

    less than 450 for flaming or non flaming mode,

    compressive strength as per ASTM-D3501-86A

    shall not be less than 52 MPa parallel to grain, 17

    MPa perpendicular to grain & 116 MPa flat at

    50% strain. Tensile strength as per ASTM-D3500-

    90 shall not be less than 105 MPa parallel to grain,

    Slip resistance coefficient of friction as per ASTM

    D2047 shall be 0.71, Abrasion resistance weight

    loss as per ASTM-C501 shall not be more than

    350 gms (H-22 calibrated wheels loaded with 1000

    gms weight at 70 RPM for 1000 cycles) and

    Moisture content as per ASTM-D4442 oven dry

    method shall not be more than 7.8%. (Skirting

    profiles, trims etc shall be included & not paid

    extra)

    Sqm 272.00

    Broadloom Carpet Flooring Type-A

    1.10 Providing and fixing Carpet Flooring using

    Broadloom (Roll type) carpet of approved make,

    shade and pattern and of the following

    specification: Tufted cut pile, 1/10 gauge with

    100% Polyamide Millitron/ 6 Crealon (R) nylon/

    SD Nylon pile or equivalent material having

    minimum surface pile thickness of 5.3 mm and

    minimum total thickness of 7.1 mm with Contract

    Latex backing/ 'Weave back (R) backing/ Woven

    Polypropylene backing, min. tufts of 201500 per

    sqm and minimum total carpet weight of 2300

    g/sqm, minimum pile yarn weight of 1200 g/sqm,

    minimum surface pile density of 0.141 g/ cucm

    having inbuilt anti-soiling protection, suitable for

    commercial-heavy use areas like auditorium

    application, having acoustical insulation value of

    31 dB, CE labeled, EC certified, fulfilling Fire

    Classifications EN 13501-1 euro class and

    approved by Green Label Plus test for indoor

    hygiene in standard length and width.

    Sqm. 2,023.00

    Tiled Carpet flooring Type-B

    1.11 Providing and fixing Carpet flooring using CarpetTile of approved make, shade and pattern and of

    the following specification: Loop pile carpet tile,

    5/64 gauge of size 500 mm x 500 mm/ 610 mm x

    610 mm with Minituft loop construction, 100%

    Econyl Aquafil pile material/ Zeftron (R) yarn,

    100% recycled solution dyed Nylon or equivalent

    having minimum pile height of 0.8mm and

    maximum total height of 6.5mm with secondary

    backing of Back to Back modified bitumen,

    Sqm. 732.00

  • 7/24/2019 Vol II (ICAR Audi Interior 2013)

    7/50

    S.N. DESCRIPTION OF ITEM UNIT QTY AMOUNT in figu

    (Rs.)

    in figures in words

    RATE (in Rs.)

    enhanced with a thermoplastic elastomer,

    reinforced with a glass fiber fleece covered with

    100% PES fleece including 10% recycled content/

    non woven primary backing and secondary

    backing of Nexterra (R) with min. 40% total

    recycled content, minimum tuft density 190,000 /

    sqm, minimum total carpet weight of 3,350 g/sqm, minimum pile weight of 480 g/ sqm, pile

    above backing of minimum 176 g/ sqm, minimum

    pile density of 0.220 g/ cucm, having minimum

    impact noise rating of 10 dB suitable for

    continuous use of castor wheel chairs as per EN

    985 and fire resistance property as per EN 13501-1

    and permanent anti-static 2 kV/ DOC FF-1-70,

    static control

  • 7/24/2019 Vol II (ICAR Audi Interior 2013)

    8/50

    S.N. DESCRIPTION OF ITEM UNIT QTY AMOUNT in figu

    (Rs.)

    in figures in words

    RATE (in Rs.)

    2.01 Providing & applying Plaster of Paris (gypsum

    anhydrous) suspended false ceiling up to any

    height above floor level, including fixing of frame

    work made of special sections, power pressed from

    M.S. sheets and galvanized with zinc coating of

    120 gms/sqm (both side inclusive). Consisting of

    angle cleats of size 25 mm wide x 1.6 mm thickwith flanges of 27 mm and 37mm, at 1200 mm

    centre to centre, one flange fixed to the ceiling

    with dash fastener 12.5 mm dia x 50mm long with

    6mm dia bolts. Other flange of cleat fixed to the

    angle hangers of 25x10x0.50 mm of required

    length with nuts & bolts of required size. The other

    end of angle hanger fixed with intermediate G.I.

    channels 45x15x0.9 mm running at the spacing of

    1200 mm centre to centre, to which the ceiling

    section 0.5 mm thick bottom wedge of 80 mm

    with tapered flanges of 26 mm each having lips of

    10.5 mm, at 450 mm centre to centre.

    This shall be fixed in a direction perpendicular to

    G.I. intermediate channel with connecting clips

    made out of 2.64 mm dia x 230 mm long G.I. wire

    at every junction, including fixing perimeter

    channels 0.5 mm thick 27 mm high having flanges

    of 20 mm and 30 mm long, the perimeter of

    ceiling fixed to wall/partition with the help of rawl

    plugs at 450 mm centre, with 25mm long dry wall

    screws @ 230 mm interval and reinforced with

    rabbit wire mesh of 100mmx16mm gauge fixed to

    2.01.1 Flat surfaces Sqm. 1,180.00

    2.01.2 Curved surfaces Sqm. 128.00

    Gypsum Board False Ceiling2.02 Providing and fixing false ceiling at all height

    including providing and fixing of frame work

    made of special sections, power pressed from M.S.

    sheets and galvanized with zinc coating of 120

    gms/sqm (both side inclusive) as per IS : 277 and

    consisting of angle cleats of size 25 mm wide x 1.6

    mm thick with flanges of 27 mm and 37mm, at

    1200 mm centre to centre, one flange fixed to the

    ceiling with dash fastener 12.5 mm dia x 50mm

    long with 6mm dia bolts, other flange of cleat

    fixed to the angle hangers of 25x10x0.50 mm of

    required length with nuts & bolts of required size

    and other end of angle hanger fixed with

    intermediate G.I. channels 45x15x0.9 mm running

    at the spacing of 1200 mm centre to centre, towhich the ceiling section 0.5 mm thick bottom

    wedge of 80 mm with tapered flanges of 26 mm

    each having lips of 10.5 mm, at 450 mm centre to

    centre.

    (Nothing extra shall be paid for openings for

    grilles, electrical fixtures etc. and vertical/inclined

    face shall be measured above 200mm high only).

    2.02.1 12.5 mm thick tapered edge gypsum fire resistant

    board conformin to IS: 2095- Part I

    Sqm. 1,015.00

  • 7/24/2019 Vol II (ICAR Audi Interior 2013)

    9/50

    S.N. DESCRIPTION OF ITEM UNIT QTY AMOUNT in figu

    (Rs.)

    in figures in words

    RATE (in Rs.)

    2.02.2 12.5 mm thick tapered edge gypsum moisture

    resistant board.

    Sqm. 85.00

    2.02.3 Specification same as above but for providing &

    fixing of 25mm (2 layers of 12.5mm) Gypsum

    board (moisture resistant) fixed on galvanized steel

    framework. All framework suspension system asper manufacturer specification as required to

    withstand the load. The parimeter channel to be

    screw fixed to brick/concrete wall with rawl plugs

    and screws. The lower level of Gypsum board to

    have joints over frame and to be fixed at max.

    300mm c/c, to the frame and second layer have

    staggered joints and to be fixed to the first layer.

    All joints to be taped with paper tape and filled

    with jointing compound to provide smooth

    surface, Entire work to be done as per

    specifications including painting two coats of

    primer and as per directions of E-I-C.

    Sqm. 4,953.00

    2.02.4 Extra for fixing Gypsum Board False Ceiling in

    Zigzag Profile (As per Drawing in Auditorium

    area

    Sqm. 2,129.00

    2.02.5 Fully Perforated Gypsum Plaster Board of size

    1200 x 2400x12.5 mm having approx. 15 %

    perforated area with perforation size and pattern as

    approved and as per manufacturer's specification,

    with all 4 side tapered and backed by acoustical

    tissue with NRC value not less than 0.60

    Sqm 1,428.00

    2.02.6 Providing & fixing thermal insulation of ceiling

    with Resin Bonded Fiber glass wool conforming to

    IS : 8183, density 24kg / m3, 50mm thick,

    wrapped in 200 gms virgin polythene bags/jute

    bags, fixed to ceiling with metallic cleats

    (50x50x3 mm) @ 60 cm and wire mesh of 12.5

    mm x 24 gauge wire mesh. (above gypsum board

    Sqm 2,170.00

    2.03 Providing and fixing tiled false ceiling of approved

    materials of size 595x595 mm in true horizontal

    level, suspended on inter locking metal grid of hot

    dipped galvanized steel sections (galvanized @

    120 grams/sqm, both side inclusive) consisting of

    main "T" runner with suitably spaced joints to get

    required length and of size 24x38 mm made from

    0.30 mm thick (minimum) sheet, spaced at 1200

    mm center to center and cross "T" of size 24x25

    mm made of 0.30 mm thick (minimum)sheet,

    1200 mm long spaced between main "T" at 600mm center to center to form a grid of 1200x600

    mm and secondary cross "T" of length 600 mm

    and size 24x25 mm made of 0.30 mm thick

    (minimum) sheet to be interlocked at middle of the

    1200x600 mm panel to form grids of 600x600 mm

    and wall angle of size 24x24x0.3 mm and

  • 7/24/2019 Vol II (ICAR Audi Interior 2013)

    10/50

    S.N. DESCRIPTION OF ITEM UNIT QTY AMOUNT in figu

    (Rs.)

    in figures in words

    RATE (in Rs.)

    laying false ceiling tiles of approved texture in the

    grid including, required cutting/making, opening

    for services like diffusers, grills, light fittings,

    fixtures, smoke detectors etc. Main "T" runners to

    be suspended from ceiling using GI slotted cleats

    of size 27 x 37 x 25 x1.6 mm fixed to ceiling with

    12.5 mm dia and 50 mm long dash fasteners, 4mmGI adjustable rods with galvanised butterfly level

    clips of size 85 x 30 x 0.8 mm spaced at 1200 mm

    center to center along main T, bottom exposed

    width of 24 mm of all T-sections shall be pre-

    painted with polyester paint, all complete for all

    heights as per specifications, drawings and as

    directed by Engineer-in-charge.

    2.03.1 12.5 mm thick square edge PVC Laminated

    Gypsum Tile of size 595x595 mm, made of

    Gypsum plasterboard, manufactured from natural

    gypsum as per IS 2095 part I and laminated with

    white 0.16mm thick fire retardant PVC film on the

    face side and 12micron metalized polyester on the

    back side with all edges sealed with the face sidePVC film which goes around and wraps the edges

    and is bonded to the edges and the back side

    metalized polyester film so as to make the tile a

    completely sealed unit.

    Sqm. 687.00

    2.04 Acoustic Ceiling Tiles

    2.04.1 Providing and Fixing Acoustic tiles of 15 mm

    thickness and tegular edge, easily demountable

    tile, manufactured from High density glass wool,

    with the visible surface batch painted glass tissue

    in white and the back of the tile should be

    covered with glass tissue. The glass wool core of

    the tiles should be tested and classified as non-

    combustible according to prEN ISO 1182. Thesystem should have Sound Absorption NRC value

    of 0.9 (according to ASTM C 423). Tiles should

    withstand a permanent ambient RH Upto 95% at

    30*C without sagging, warping or delaminating

    (ISO 4611). The light reflectance of the tiles

    should not be less than 83%. Tiles certified by the

    indoor climate labeling and recommended by

    Swedish asthama and allergy association and

    granted Nordic Swan ecolabel and fully

    recyclable. The glass wool core of the tiles should

    be tested and classified as non combustible

    according to EN ISO 1182 and the ceilings should

    fall under Class A2 s1 d0 according to EN 13501

    1.

    Sqm. 837.00

  • 7/24/2019 Vol II (ICAR Audi Interior 2013)

    11/50

    S.N. DESCRIPTION OF ITEM UNIT QTY AMOUNT in figu

    (Rs.)

    in figures in words

    RATE (in Rs.)

    2.04.2 Providing and Fixing Acoustic tiles of 20 mm

    thickness natural square edge, easily demountable

    tile, manufactured from High density glass wool,

    with the visible surface is a matt blackbatch

    painted glass tissue and the back of the ti le should

    be covered with glass tissue. The glass wool core

    of the tiles should be tested and classified as noncombustible according to prEN ISO 1182. The

    system should have Sound Absorption NRC value

    of 0.9 (according to EN ISO 11654). Tiles should

    withstand a permanent ambient RH Upto 95% at

    30*C without sagging, warping or

    delaminating (ISO 4611). The light reflectance of

    the tiles should not be more than 3- 4 %.

    Sqm. 259.00

    Wooden False Ceiling

    2.05 Providing and Fixing Wooden false Ceiling

    comprising of a Galvanized MS frame as required

    covered with 12 mm thick Marine ply, followed by

    6 mm premium quality MDF for making groove

    and finished with a natural veneer (as approved) of

    3.5 mm thickness duly Spirit polished with

    melamine matt coating. The ceiling shall be fixed

    to the roof soffit with adequate suspenders. The

    item shall be inclusive of cutting & making

    cutouts for lights, diffusers etc all complete.

    (veneer with basic cost Upto Rs:100 per sft FOR

    site)

    Sqm. 405.00

    Perforated Metallic ceiling Type-B: Clip in Tile

    2.06 Providing & installing Clip in tiles/plank ceiling

    made out of Aluminum. The ceiling tiles shall bein size of 600x600x0.7mm (thk), perforated to L15

    pattern (2.5mm diameter holes, 16% opening) with

    Soundtex Tissue laminated at the back, beveled

    edges on 4 sides, clipped into secondary clip in

    profiles at 600mm c/c. The clip-in profiles shall be

    cross connected to C-channel primary through

    threaded rod hangers spaced at 1200mm c/c.

    Finish of ceiling tiles:RAL 9016 white polyester

    powder coat finish with minimum 60 microns

    paint thickness or as approved.

    Sqm. 634.00

    2.07 LINEAR BAFFLE CEILING

    Providing & installation of approved quality

    vertical linear baffle ceiling made out of folded

    Aluminum. The baffle units shall be in size of

    50mm (W) x 150mm (H) and 1000mm x 4500mm

    x 1mm (thk), non-perforated. The ceiling baffle

    units shall be installed at a distance of 300mm c/c

    in one direction. The baffle units shall be attached

    to C-channel carriers spaced at 1200mm c/c. The

    C-channel carriers shall then be cross connected to

    perforated L-angle primary grid and suspended

    with M6 threaded rod hangers spaced at 1200mm

  • 7/24/2019 Vol II (ICAR Audi Interior 2013)

    12/50

    S.N. DESCRIPTION OF ITEM UNIT QTY AMOUNT in figu

    (Rs.)

    in figures in words

    RATE (in Rs.)

    2.07.1 Baffles finished with RAL 9016 selected wood

    grain with minimum 60 microns paint thickness.

    Sqm. 298.00

    2.07.2 Baffle finished with RAL 9016 polyester powder

    coat with minimum 60 microns paint thickness.

    Sqm. 444.00

    2.08 WOODEN PLANK CEILING (NON-

    PERFORATED & PERFORATED)

    2.08.1 Providing & installing of approved quality timber

    effect Ceiling Highlighter panels hook-on ceiling

    made out of fire rated MDF core material. The

    ceiling panels shall be in size of 600x1200x16mm

    thk (Non Perforated panels surfacesPanels and

    support grids to be used as a proprietary system

    from a single source manufacturer and shall be

    produced in accordance to metal ceiling industry

    standard TAIM (Technical Working Group of

    Industrial Metal Ceiling Manufacturers). Panels

    tolerances shall be according to +/- 2.0mm on

    width and length of panels. Panels deflection shall

    be allowable up to L/360.surface. The ceiling

    planks shall be with square edges on 4 sides,

    hooked along the length . The hook on profiles

    shall then be cross connected to perforated L-

    angle primary grid and suspended with M6

    threaded rod hangers spaced 1200mm C/C. Finish

    of ceiling panels shall be Timber effect melamine

    wooden finish.

    Sqm. 20.00

    2.08.2 Providing and installation of timber effect

    melamine finish hook-on ceiling made out of fire

    rated MDF core material. The ceiling panels shall

    be in size of 600x1200x16mm (thk), perforated

    to 3mm diameter holes, 16mm c.c at front &

    10mm dia holes @ 16mm C/C at the back. There

    will be a layer of Soundtex tissue laminated at the

    back of ceiling panels. The ceiling planks shall be

    with square edges on 4 sides, hooked along the

    length . The hook on profiles are then cross

    connected to perforated L- angle primary grid and

    suspended with M6 threaded rod hangers spaced

    1200mm C/C complete with all arrangement and

    as per direction of E-I-C. Finishes of ceiling

    panels: Timber effect Melamine finish.

    Sqm. 10.00

    MICRO-PERFORATED METAL CEILING

    TYPE-A: 2D CEILING

  • 7/24/2019 Vol II (ICAR Audi Interior 2013)

    13/50

    S.N. DESCRIPTION OF ITEM UNIT QTY AMOUNT in figu

    (Rs.)

    in figures in words

    RATE (in Rs.)

    2.09 Providing & Installation of Metal Ceiling micro-

    perforated with fleece backing. The ceiling panels

    shall be in customized sizes to provide 2D effect,

    micro- perforated with Soundtex acoustic fleece

    L15 pattern (1.5mm diameter holes, 22% opening

    approx). The ceiling planks shall be with square

    edges on 4 sides, hook onto secondary hook onprofiles. The hook on profiles are then cross

    connected to perforated L-angle primary grid and

    suspended with M6 threaded rod hangers spaced

    1200mm C/C. and providing and laying 50mm

    thick resin bonded glass wool (24 kg /m3) over

    perforated ceiling planks.

    Finishes of ceiling tiles/ planks: RAL 9016 white

    polyester powder coat finish with minimum 60

    microns paint thickness or as approved and as per

    dirction of E-I-C.

    Sqm. 755.00

    OPEN CELL CEILING

    2.10 Providing and installation of approved quality

    linear cell ceiling made out of 0.5 mm thick

    Aluminum. The assembled cell ceiling panels shall

    be made out of main blades in 15mm (W) x 40mm

    (H) in 1200mm (L), installed at 200 mm c/c. and

    cross connected to secondary blades in 15mm(W)

    x 40mm(H) in 600mm(L) with 100 mm pitch. The

    assembled cell ceiling panels shall be clipped into

    U-94 carriers in GMS, pre-coated in black

    enameled finished at 1200mm c/c. Wire clips shall

    hold the cell ceiling panels into the U-94 carriers.

    The Primary angles made out of GMS, type U1040

    are cross connected to the U-94 carriers at

    1200mm c/c., for lateral bracing the whole ceiling

    shall be suspended by M6 threaded rods. All panelmodules must be hinge able through wire clips &

    grid should not be visible from bottom. Black

    soundex tissue to be pasted at the back of the

    panels to block visibility of internal service piping

    installed on ceiling.

    Finish of cell ceiling panels: Metallic silver in

    RAL 9006/White in RAL 9016/Natural Aluminum

    finish (Black or as approved). including Providing

    and installation of 50mm thick resin bonded glass

    wool (24 kg/cum)with GI frame fixed on roof slab

    with frame held on 24G x 10 GI wire mesh

    covered with black jute fabric over open Cell

    Metal Ceiling.

    Sqm 2,236.00

    STEEL WIRE ROPE HANGERS &

    SUPPORTS:

    2.11 Supply, Fabrication, installation and testing of all

    false ceiling with Wire Rope Hangers & Supports

    complete with end fixing in accordance with the

    approved shop drawings and as required by the

    specifications.

    2.11.1 Taking working load Upto 45 kg Nos 2,167.00

    2.11.2 Taking working load 46 to 90 kg Nos 271.00

  • 7/24/2019 Vol II (ICAR Audi Interior 2013)

    14/50

    S.N. DESCRIPTION OF ITEM UNIT QTY AMOUNT in figu

    (Rs.)

    in figures in words

    RATE (in Rs.)

    2.11.3 Taking working load 91 to 225 kg Nos 271.00

    3.00 SPECIALIZED ITEMS

    3.01 SLIDING FOLDING PARTITION

    3.01.1 Sound Barrier Partition above Operable

    Sliding/Folding Partition (Audi (S.F.),

    Multipurpose Dining (G.F.) and Training Rooms

    G.F.

    Sqm 468.00

    Providing and fixing to the required profile and

    shape 2 layers of 12.5mm thick Gypsum board (on

    both sides of barrier) on GI framework comprising

    40x40x18G tubular frame painted with red oxide

    anti corrosion paint 610x610mm centre to centre

    fixed on Roof Structure with 40x40x5 MS

    galvanised cleat, 100mm long 1200 c/c and ceiling

    framework with welded connections. The Gypsum

    board (on both sides of barrier) to be backed with

    50mm thick resin bonded fiber glass insulation (24kg/cum) cut to size and inserted in GI framework

    and held in place with 28G x 12mm GI wire

    netting. The first layer of Gypsum board to have

    joints over frame and second layer of Gypsum

    board to have joint staggered with respect to the

    first layer, all joints between board in both layers

    to be taped with paper tape and filled with sealing

    compound.

    Gypsum board layer to be sealed at junction with

    Roof sheeting/ structure and false ceiling below

    with the non-hardening mastic compound, so as to

    provide smooth surface. Entire work to be done as

    per drawing, specifications and directions as perE

    I-C.

    3.01.2 Operable Acoustic Partitions (Type 1)- Audi

    (S.F.), Multipurpose Dining (G.F.) (One side

    perforated) with openable and foldable doors

    alongwith complete arrangement and fittings

    required and as per the drawings.

  • 7/24/2019 Vol II (ICAR Audi Interior 2013)

    15/50

    S.N. DESCRIPTION OF ITEM UNIT QTY AMOUNT in figu

    (Rs.)

    in figures in words

    RATE (in Rs.)

    Supply and installation of operable acoustical

    partitions in designated area comprising individual

    panels100mm thick and maximum 1200mm wide

    Panels shall be of all steel construction and shall

    fully enclose and protect all edges of surface

    material with protective edge trim. Panel skins

    shall be Steel class A rated as per ASTM E84laminated to steel structure and acoustical backing,

    mounted in full aluminium profile perimeter

    protective frames, Panels shall have one face

    perforated with 33% open perforated steel and

    underlay sound control blanket and septum

    providing 0.65 NRC. Vertical sound seals between

    panels shall be tounge and groove configuration

    incorporating vinyl acoustical seals Panel weight

    shall not exceed 55 kg/sqm. Panels shall be

    suspended from roll-formed steel track system

    suspended from steel supports by threaded rods.

    Each panel shall be top supported by two trolley

    assemblies comprising steel ball bearing wheels.

    Partitions to be complete, finished with fire

    retardant fabric in both side num finish (Black oras a

    Panels shall have operable top and bottom seals

    simultaneously operated by a removable handle.

    The seals shall not contact floor or track during

    movement of panels. Panels shall also feature

    horizontal seals for stabilization and acoustic

    performance. Final partition closure to be

    accomplished by lever closure panel of same

    construction as basic panel but provided with an

    expanding jamb operated by a removable handle.

    The partition shall have been tested by an

    independent acoustical laboratory and shall have

    weighted SRI (Rw) of at least 51 in accordance

    with ASTM E90/DIN 52210. After installation,

    operable partition shall be tested by manufacturer

    in presence of client's representative and

    consultant. Noise reduction measurements shall be

    made in accordance with ASTM E336. NIC shall

    be calculated as per ASTM E413. Noise reduction

    shall meet NIC 51. Entire work to be done

    complete as per drawings, specifications and

    direction of E-I-C

    3.01.2.1 Operable Acoustic Partitions (Type 1)- One side

    perforated with Automatic seal for Audi (S.F.)

    with i/c fittings & openable and foldable doors

    alongwith complete arrangement and fittings

    required and as per drawings.

    Sqm 456.00

    3.01.2.2 Operable Acoustic Partitions (Type 1)- One side

    perforated with Automatic seal for Multipurpose

    Dining (G.F.) with openable and foldable doors

    alongwith complete arrangement and fittings

    required and as per the drawing.

    Sqm 141.00

  • 7/24/2019 Vol II (ICAR Audi Interior 2013)

    16/50

    S.N. DESCRIPTION OF ITEM UNIT QTY AMOUNT in figu

    (Rs.)

    in figures in words

    RATE (in Rs.)

    3.01.3 Operable Acoustic Partitions (Type 2)

    Training rooms (G.F.) (Without perforation) with

    openable and foldable doors alongwith complete

    arrangement and fittings required and as per the

    drawing.

    Sqm 165.00

    Supply and installation of operable acousticalpartitions in designated area comprising individual

    panels 100mm thick and maximum 1200mm wide

    Panels shall be of all Steel construction and shall

    fully enclose and protect all edges of surface

    material with protective edge trim. Panel skins

    shall be of MDF Board (good quality Exterior

    Grade) laminated to steel structure and acoustical

    backing, mounted in full aluminium profile

    perimeter protective frames. Vertical sound seals

    between panels shall be tounge and groove

    configuration incorporating vinyl acoustical seals

    Panel weight shall not exceed 55 kg/sqm. Panels

    shall be suspended from roll-formed steel track

    system suspended from steel supports by threaded

    rods. Each panel shall be top supported by twotrolley assemblies comprising steel ball bearing

    wheels. Partitions to be complete with Veneer in

    both sides as per approved sample (with a base

    rate of Rs. 200 Per Sqft).

    Panels shall have operable top and bottom seals

    simultaneously operated by a removable handle.

    The seals shall not contact floor or track during

    movement of panels. Panels shall also feature

    horizontal seals for stabilization and acoustic

    performance. Final partition closure to be

    accomplished by lever closure panel of same

    construction as basic panel but provided with an

    expanding jamb operated by a removable handle.

    The partition shall have been tested by an

    independent acoustical laboratory and shall have

    weighted SRI (Rw) of at least 51 in accordance

    with ASTM E90/DIN 52210. After installation,

    operable partition shall be tested by manufacturer

    in presence of clients representative and

    consultant. Noise reduction measurements shall be

    made in accordance with ASTM E336. NIC shall

    be calculated as per ASTM E413. Noise reduction

    shall meet NIC 51. Entire work to be done

    complete as per drawings, specifications and

    direction of E-I-C.

    3.02 SS HANDRAIL

  • 7/24/2019 Vol II (ICAR Audi Interior 2013)

    17/50

    S.N. DESCRIPTION OF ITEM UNIT QTY AMOUNT in figu

    (Rs.)

    in figures in words

    RATE (in Rs.)

    3.02.1 Supply and installation of modular and component

    (Weld free) based system of satin finish stainless

    steel AISI 304 SS handrail and balustrade system

    having minimum 38mm dia tube handrail (1.5mm

    thickness) (app weight 1.5 kgs per Rmt) handrail

    connected with unified stem keys in bead blasted

    finish to 12X54 mm stain free finish solid (approxweight 7.5 to 7.7 Kgs) flat vertical member to be

    fixed on the side of staircase (2-point fixed) with

    circular solid bosses of 50 mm dia at max c/c

    distance of 1800 mm with anchor fasteners to the

    wall having infill of minimum 10 mm thick

    toughened glass complete with all necessary bends

    and termination. Ht. 900-1000 mm. System as per

    tested and recommended by BS certification of BS

    6180:1995 from British Standard Institute and as

    per MTC. Rate for the complete unit is payable in

    running meter and includes Handrail Tube,

    Uprights Solid, unified Cherry/Maple key,

    Toughened glass etc, including installation and

    making good the floors if required as per direction

    of E-I-C.

    Rmt 102.00

    3.03 WATER CURTAIN: Nos 2.00

    Providing & installation of water curtain as per the

    specification mentioned below including material

    as listed below. Job includes preparation of Shop

    Drawing & installation etc all complete:

    Inclusions:

    NOZZLES: Supply of 304 Gr Stainless Steel

    manifold having 130 nos brass spray nozzles

    (MOC GM/Brass) complete with bottom tieing

    support, clear strings as required. (1 No for each

    fountainLIGHTS

    a) Supply of 24V DC, 5x1 W LED linear light,

    (WW)color under water luminary with wide beam

    super magnifying lense (MOC Al) Protection

    Index IP 68. (7 No for each fountain)

    b) Supply of ABS Casing for 5 X 1 W LED Lights.

    (7 No for each fountain)

    c) Supply of Waterproof joints. (7 No for each

    fountain)

    d) Supply of constant voltage LED driver input

    AC 220-250 volts, output 24 V DC. (1 No for each

    fountain

    PUMPS: Supply of prefilter basket pump set

    delivering. Body made in glass loadedpolypropylene, impeller in PPO, mounting seal in

    glass loaded polyamide, motor shaft in stainless

    steel AISI 420, mechanical seal in graphite and

    steatite, motor housing in AL L 2521, protection

    index IP 55, single phase built in thermal

    rotection 1 no for each fountainDOSING PUMP UNIT: Supply of online

    Chlorine Dosing injector with mechanical

    connections complete as required. (1 no for each

    fountain .MULTI MEDIA SAND FILTER

  • 7/24/2019 Vol II (ICAR Audi Interior 2013)

    18/50

    S.N. DESCRIPTION OF ITEM UNIT QTY AMOUNT in figu

    (Rs.)

    in figures in words

    RATE (in Rs.)

    a) Providing of FRP pressure High rate Sand

    Filter for filtration of suspended material from

    water body complete with six position multiport

    valve for filter,backwash,rinse,waste ,recirculate

    and close all flow to pool the filter body

    manufactures in fiber glass with uV .resistance

    surface provided with oil pressure gauge cap 19.5cum/hr, 700 mm dia filter pressure 2.5 Kg/sqcm.

    b) Supply of Silica sand for filter with

    granulometry between 0.4-0.8 mm. (210 kg (app)

    for each fountain)

    ELECTRICAL CONTROL PANEL:Supply of

    Cubical Control Panel made of 16 gauge CRC

    sheet powder coated with Starter, Single phase

    prevention, MCB, TP MCB's, Protection circuits

    etc and space for CVD for the lights. (1 Set for

    each fountainu PVC PIPING: Providing and fixing uPVC

    pipes (10kg. Pressure) including accessories &

    fittings as required (Elbow, MTA, End cap,

    Socket, Tee, Reducing Tee etc.) (1complete job foreach fountain)

    SUPPLY OF BALL VALVES WITH

    FITTINGS AS REQUIRED.

    a) Supply of Anti vortex complete as required.

    (1no for each fountain)

    b) Supply of 63 mm dia uPVC ball valves. (3 no

    for each fountain)

    c) Supply of 50 mm dia Gun Metal Non Return

    Valve. (1no for each fountain)

    CABLE & CONDUITING: Supply of double

    sheated cables of various sizes including

    accessories etc required (PVC Conduit, PVC

    Bend, Steel wire, etc.) for final equipment

    connections with control anel.a) Three Core copper double sheated submersible

    cable(Motors) with conduit. (1 complete job for

    each fountain)

    b) Wire 1.5mm Three Core round flexible sheathed

    insulated( Lights) (1 complete job for each

    fountain

    3.04 Retractable Seating Nos 384.00

    Providing & installation of retractable seating

    system with the specification as mentioned below:

    Maximum Hall multifunctionally automatic

    system based on retractable risers with folding &

    unfolding mechanism. Telescopic risers ensures

    optimal sight from any position. Electric traction

    mechanism & pneumatic seat folding & unfoldingsystem. Safety equipped with a device that blocks

    the movement of riser if there are obstracles in

    their run. Maintanence & durability: Chairs are

    protected against all external agents when not in

    use. & simultaneous configuration of risers &

    access stairs protects the risers also. Depending

    upon the type of chairs used the riser height can

    vary between 320 to 450 mm.

  • 7/24/2019 Vol II (ICAR Audi Interior 2013)

    19/50

    S.N. DESCRIPTION OF ITEM UNIT QTY AMOUNT in figu

    (Rs.)

    in figures in words

    RATE (in Rs.)

    Chairs have center to center dimension of 500

    mm, Beam mounted 3 to 4 chairs, 150 mm upright

    position profile, upholstry system consisting of a

    single block with internal structure & inherent fire

    retardant fabric & foam Ergonomic & keep shape

    single block covered with easily changeble zip-ion

    upholstery. Soft system, silent cushinoned tip upsystem for seat, backrest & armrest prevents any

    bump or annoying sounds. maintanence free

    gravity folding mechanism & product should

    comply with international fire regulation.The

    seating should be as per the drawing and complete

    drawing alongwith the details is to be provided

    and get approved by E-I-C for complete

    functionary of the system.The rate should include

    complete system installation and all statutory

    application taxes warranty tests etc.

    4.00 WALL FINISHES

    Note:

    1) All unprotected surfaces of wood, MDF, Ply etc.

    shall be treated with anti-termite paint, fire

    retardant moisture resistant & black Japan

    protective paint coatings.

    2) All wood work shall be dry and moisture

    content should be within permissible limit.

    4.01 Providing & applying 4 mm thick (avg) P.O.P.

    punning (calcium sulphate semi-hydrate variety)

    over old / new wall surface by hacking of the

    existing surface for proper bond including

    rounding and chamfering of corners and junctions

    and providing and fixing M.S. angle beading atcorners wherever required to give a smooth surface

    true in line and plumb including making grooves

    as per design. This item includes scaffolding,

    protection of adjoining surfaces & cleaning etc.

    complete and as per direction of E-I-C.

    Sqm. 6,102.00

    4.02 Wall Paneling

    4.02.1 Base Frame for paneling

    4.02.1.1 Providing & fixing base frame of 50x 50 mm

    Marandi Wood treated with anti termite chemical

    and fire retardant paint of approved maker,

    provided at an average spacing of 600mm c/c both

    ways adequately to the wall in line and plumb with

    the help of wooden plugs and screws fixed to wall& tightened etc all completeas per direction of E-I-

    C

    Sqm 178.00

  • 7/24/2019 Vol II (ICAR Audi Interior 2013)

    20/50

    S.N. DESCRIPTION OF ITEM UNIT QTY AMOUNT in figu

    (Rs.)

    in figures in words

    RATE (in Rs.)

    4.02.1.2 Providing and fixing structural steel frame (for

    cladding of wooden partitions/Paneling) on walls

    at all heights using Galvanized M.S. square/

    rectangular tube in the required pattern as per

    architectural drawing, including cost of cutting,

    bending, welding etc. The frame work shall be

    fixed to the wall with the help of Galvanized M.S.brackets/ lugs of angle iron/ flats or anchor

    fasteners etc. which shall be welded to the frame

    and embedded in brick wall with cement concrete

    block 1:2:4 (1 cement :2 coarse sand :4 graded

    stone aggregate 20 mm nominal size) of size

    300x230x300 mm, including cost of necessary

    centering and shuttering and with approved

    expansion hold fasteners on CC/RCC surface,

    including drilling necessary holes.

    Kg 21,284.00

    4.02.2 Providing and fixing thermal insulation with Resin

    Bonded Fibre glass wool conforming to IS: 8183

    having density 24 kg/m3, 50 mm thick, wrapped

    in 200G Virgin Polythene Bags fixed to wall withscrew, rawel plug & washers and held in position

    by criss crossing GI wire etc. complete as per

    directions of Engineer-in-Charge.

    Sqm. 6,091.00

    Veneer Finished Paneling Type-A & B:

    4.02.3 Providing and fixing Veneer finished wooden wall

    paneling in portals & frames (as per drawing &

    approval), Panels of 6 mm MDF board cold

    pressed with 3.5 mm thick natural wood veneer

    duly Spirit polished and melamine matt coat in

    design and pattern as per drawings & as approved

    fixed over a sub strata of 12 mm thick MDF board

    duly screwed to the base frame. The panels shallbe fixed leaving a precise gap of 10 mm between

    two panels. The sides of frame touching the

    masonry will be painted with black Japan. (Base

    Frame to be paid in respective Item). (Basic Rate

    of Veneer=RS.100/- per sft FOR site)

    Sqm. 1,529.00

    Metallic Laminate Paneling Type-A & B:

    4.02.4 Providing and fixing Metallic Laminate finished

    wooden wall paneling with 6 mm thick MDF

    board cold pressed with SS Metallic Laminate (1.5

    mm thick) of approved shade and make in design

    and pattern as per drawings fixed over a sub strata

    of 12 mm MDF board duly screwed to the baseframe. The panels shall be fixed leaving a precise

    gap of 10 mm between two panels. The sides of

    frame touching the masonry will be painted with

    black Japan. (Base Frame to be paid in respective

    Item). (Basic Rate of SS Metallic

    Laminate=RS.140/- per sft FOR site)

    Sqm. 170.00

  • 7/24/2019 Vol II (ICAR Audi Interior 2013)

    21/50

    S.N. DESCRIPTION OF ITEM UNIT QTY AMOUNT in figu

    (Rs.)

    in figures in words

    RATE (in Rs.)

    4.02.5 Providing & Fixing of Panels of 12.5 mm thk

    Gypsum board screwed to the wooden/Galvanized

    MS base frame over 6 mm thk. MDF and finished

    with paper tape, joining compound and top coat of

    primer as required. (Base Frame to be paid in

    respective Item)

    Sqm. 82.00

    4.02.6 Providing & Fixing of Panels of 12 mm thk MDF

    screwed to the wooden/Galvanized MS base frame

    as per drawings and finished with top coat of anti-

    termite paint and as required. (Base frame to be

    aid in res ective item

    Sqm. 1,603.00

    4.02.7 Providing & Installation of Panels of 17 mm thk

    Superior Quality MDF Routed as per design

    screwed to the wooden/Galvanized MS base frame

    over 6 mm thk. MDF as per drawings and finished

    as approved. (Base Frame & finishing to be paid in

    respective Item)

    Sqm. 387.00

    4.02.8 Extra for finishing the Routed MDF panels with:

    4.02.8.1 High Gloss Automotive paint as per the approved

    sam les.

    Sqm. 349.00

    4.02.8.2 High Gloss Spray Enamel Paint as per the

    approved samples.

    Sqm. 39.00

    4.02.9 Acoustic Lattice Paneling Type-A, B & C:

    Providing and fixing (American Walnut or as

    approved) finished Acoustical Lattice wooden wall

    paneling consisting of base frame treated with antitermite chemical of approved make. Panels to be

    installed as per specification. The Timber

    melamine effect acoustic wall panels made out of

    Fire Rated MDF core material. The acoustic wall

    panels shall be in size of 128x2440x18mm (thk).

    The back of timber melamine panels shall be

    laminated with Soundtex black acoustic tissue to

    provide NRC not less than 0.8. The acoustic

    timber wall panels shall be with tongue and groove

    detailing along the length of panels, with square

    edges on 2 sides along the width of panels. The

    wall panels shall be clipped into aluminum

    channels and clips Keel and Fastener system at

    600mm c.c. Density -800kg /m3, R.H 70, Fire

    Rated Euro Class B and C formerly Class 0 andClass 1 BS476 part 6 and 7 respectively.

    4.02.9.1 Perforated panels having perforation to 25/30 mm

    diameter holes, at 32/35 mm c/c at the back face,

    and front of the panels to have cut with grooves of

    3mm at 16mm c/c.

    Sqm. 835.00

    4.02.9.2 Non-perforated panels at back & front of the

    panels to have cut with grooves of 3mm at 16mm

    c/c.

    Sqm. 377.00

    Fabric Finished Panels

  • 7/24/2019 Vol II (ICAR Audi Interior 2013)

    22/50

    S.N. DESCRIPTION OF ITEM UNIT QTY AMOUNT in figu

    (Rs.)

    in figures in words

    RATE (in Rs.)

    4.02.10 Fabric Finished Acoustic Panels Type-A, B &

    C:

    4.02.10.1 Providing & Installing of fire retardent Fabric

    finished Wall Panel having minimum 40 mm thick

    High density glass wool with natural square edge

    (Size: 600*600 minimum or as approved),

    installed with concealed grid Hook on system anddemountable panels. Wall brackets 50*50*75 mm

    & 2.8 mm thick shall be installed @ 1200 mm c/c

    for installation of panels. Panels shall be

    manufactured from High density glass wool with

    visible surface as a glass fiber fabric and the back

    of the tile covered with glass tissue. The glass

    wool core of the tiles shall be tested and classified

    as non combustible according to prEN ISO 1182.

    The system should have Sound Absorption NRC

    value of 0.9 (according to EN ISO 11654). Tiles

    should withstand a permanent ambient RH Upto

    95% at 30*C without sagging, warping or

    delaminating (ISO 4611).

    Sqm. 2,008.00

    4.02.10.2 Fabric Finished Wood Wool Acoustic Panels

    T e-D:

    Providing and fixing fire retardent fabric on 6mm

    PU foam over 25mm thick wood wool cement slab

    as per approved sample and shade on framework

    with supports. The wood wool slabs shall be

    backed with 50mm thick resin bonded glass wool

    (24kg/m3) cut to size and inserted in framework

    and held in place with 28Gx12mm GI wire netting.

    Fabric shall be stretched flat on PU foam over

    wood wool cement slabs and fixed with rubber

    adhesive and screws complete including fixing of

    20x6mm teakwood beading over wall paneling,

    size and pattern as per drawings. All beading shall

    be wax polished after filling wood filler and sand

    papering to smooth finish. Entire work shall be

    done as per drawings, and as directed. (Basic cost

    of fabric Upto Rs. 1200/meter). (GI/MS base

    frame will be paid in the respective item)

    Sqm. 225.00

    4.02.10.3 Fabric Finished Non-Acoustic panels Type-E:

    Providing and fixing fire retardent fabric on 6mm

    thk PU foam over 12mm thick marine ply as per

    approved sample and shade on the framework

    600x600mm centre to centre (max.), fixed to wall

    surface. Fabric to be stretched flat on PU foam

    over marine ply and fixed with rubber adhesiveand screws complete including fixing of 20x6mm

    teakwood beading over wall paneling, size and

    pattern as per Architect. All beading to be wax

    polished after filling wood filler and sand papering

    up to smooth finish. Entire work to be done as

    per drawings, specifications and direction of E-I-

    C.(Basic cost of fabric Upto Rs. 1200/meter).

    (GI/MS base frame will be paid in the respective

    item)

    Sqm. 321.00

    4.02.11 Light Weight Sound Insulating partition

  • 7/24/2019 Vol II (ICAR Audi Interior 2013)

    23/50

    S.N. DESCRIPTION OF ITEM UNIT QTY AMOUNT in figu

    (Rs.)

    in figures in words

    RATE (in Rs.)

    4.02.11.1 Providing and fixing wooden Partition 150 mm

    thick including base frame of red oxide anti

    corrosion paint MS Tube as per requirement

    treated with anti corrosive red oxide of approved

    make, provided at average 600mm c/c both ways

    fixed to wall with dash fasteners and covered with

    12 mm thick Marine ply of approved make onboth side, followed by 6 mm thick superior grade

    MDF & finished with 3.5 mm thick Veneer duly

    Spirit polished with melamine matt coating with

    desired finishing. Grooves of approved size to be

    provided at joints.

    Sqm 10.00

    4.02.11.2 Providing and fixing sound insulating partition,

    122mm thick, comprising 25mm thick Gypsum

    Board (each individual layer built up with 2 layers

    12.5mm Gypsum Board) fixed on one side of

    galvanized 98x50x18G studs, 1220mm c/c frame.

    Frame members fixing system to be as per

    manufacturer. Cavity of the frame behind Gypsum

    boards to have 50mm thick fiber glass blanket (24kg/m3) and held in place with 28Gx12mm GI wire

    netting. The frame to be fixed to floor/ceiling with

    channels with 6mm dia steel screws with

    expansion fasteners, 300mm c/c in two rows

    (staggered) as per drawing. The lower layer of

    Gypsum board to have joints over frame and to be

    screwed to the frame at spacing not exceeding

    300mm c/c and second layer of Gypsum board to

    have joints staggered with respect to the first layer.

    All joints between the boards in both layers to be

    taped with paper tape and finished with jointing

    compound so as to provide smooth surface and

    joints with floor and ceiling to be mastic caulking.

    Entire work to be done as per drawing and as

    directed by E-I-C.

    Sqm 44.00

    4.02.12 Providing & Fixing of lacquer glass as per

    approval in any color fixed with clear neutral

    silicon of make GE windily 20/ slipup or Dow

    Corning 995 on a perfectly leveled Marine ply of

    minimum 12mm thickness mounted on the RCC

    wall/any other structure. The Lacquered glass shall

    be highly durable, humid resistance, polyurethane

    lacquer glass. The glass to be manufactured by

    industrial curtain coating process. It should meet

    quality standards as per BS EN 1036 1999 &

    conform to persoz hardness test of at least 220

    oscillations. The substrate of the glass should

    confirm to Standard BS EN 572 1995 parts 1 & 2.

    Lacquered glass to be manufactured to tight

    specifications, relating to consistency of color,

    opacity and homogeneity throughout production

    campaigns and also to the ageing properties,

    mechanical resistance, and resistance to humidity

    and to chemical agents of the lacquer. The color of

    the lacquer should remain stable when exposed to

    normal levels of ultra-violet light in interior

    applications.

  • 7/24/2019 Vol II (ICAR Audi Interior 2013)

    24/50

    S.N. DESCRIPTION OF ITEM UNIT QTY AMOUNT in figu

    (Rs.)

    in figures in words

    RATE (in Rs.)

    4.02.12.1 Lacquer glass of 6 mm thickness fixed with 25

    mm studs fixed on wooden/MS Base frame duly

    primer coated, covered with 1 layer of 6 mm thick

    Marine ply followed by another layer of 6 mm

    thick Superior grade MDF of approved make on

    one side. The sides of frame which touches the

    masonry will be painted with black Japan.Necessary groove of 6 mm * 6 mm required at

    joints to be provided, as per approved details etc

    all complete. (base frame to paid in respective

    item)

    Sqm. 25.00

    4.02.13 Providing and Fixing 100 mm. high skirting of

    superior quality MDF board cold pressed with 3.5

    mm thick veneer of approved quality & as per

    required design to be fixed on wall & floor

    junction including a 1st class wenge wood lipping

    on the top edge. The skirting shall be fastened to

    the wall leaving pre-determined spacing from the

    floor for fixing of carpet flooring as applicable.

    The skirting shall be true to line and plumb andshall be duly spirit polished and finished with

    melamine matt coating.

    Rmt 950.00

    4.03 GRC panel

    4.03.1 Providing & fixing Dry Cladding with GRC panel

    of 60mm thickness on internal walls upto a height

    of 10 mtrs., fixed to internal wall on structural

    steel frame work with the help of SS clamps, pins

    etc and sealing the joints with approved weather

    sealant as per the architectural drawing &

    approval. Including necessary scaffoldings

    required for installation. Installation to be done by

    specialized vendor in strict supervision if rerquired

    as per the manufacture's specification. (Thestructural frame work, SS cramps & pins etc shall

    be paid separately in respective items)

    Sqm. 34.00

    4.04 Distempering with 1st quality acrylic distemper,

    having VOC (Volatile Organic Compound)

    content less than 50 grams/ litre, of approved

    brand and manufacture, including applying

    additional coats wherever required, to achieve

    even shade and color. Including providing and

    applying white cement based putty of average

    thickness 1 mm, of approved brand and

    manufacturer, over the plastered wall surface to

    prepare the surface even and smooth complete.

    4.04.1 Two Coats Sqm. 2,648.00

  • 7/24/2019 Vol II (ICAR Audi Interior 2013)

    25/50

    S.N. DESCRIPTION OF ITEM UNIT QTY AMOUNT in figu

    (Rs.)

    in figures in words

    RATE (in Rs.)

    4.05 Wall painting with premium acrylic emulsion

    paint of interior grade, having VOC (Volatile

    Organic Compound) content less than 50 grams/

    litre of approved brand and manufacture, including

    applying additional coats wherever required to

    achieve even shade and color. Including providing

    and applying white cement based putty of averagethickness 1 mm, of approved brand and

    manufacturer, over the plastered wall surface to

    prepare the surface even and smooth complete.

    4.05.1 Two Coats Sqm. 1,954.00

    Low VOC Texture Paint Type-A, B & C:

    4.06 Providing and applying Texture Paint with a finish

    as per approved sample on interior/External wall at

    all levels i/c coat of sealer and two coats of primer

    on POP/ prepared leveled surface as per

    manufacturer's specification by a specialist

    contractor authorized by the manufacturers,

    including scaffolding, protection of adjoiningsurfaces, cleaning etc. complete.

    4.06.1 Stucco(Texture Paint Type-A):Finish of vapor

    permeable having a marble effect in three or more

    coats, finished with a steel trowel and protecting

    coats of cera wax.

    Sqm. 2,269.00

    4.06.2 Marmarino Finitura(Texture Paint Type-B):

    Finish of vapour permeable lime plaster finish for

    exterior/interior with selected marble granules in 3

    coats over a coat of primer and final coat of

    finitura polished with steel trowel and a protection

    coat of cera protectiva as per company

    s ecifications.

    Sqm. 1,572.00

    4.06.3 White Texture paint(Texture Paint Type-C):

    Finish of vapor permeable having a marble effect

    in three or more coats, finished with a steel trowel

    and rotectin coats of cera wax.

    Sqm. 307.00

    4.07 Wooden Box Paneling

    Veneer Box Paneling with marine ply

    4.07.1 Providing and fixing Veneer finished wooden Box

    paneling over existing Columns consisting of 19

    mm thick Marine ply, cold pressed with 3.5 mm

    thick veneer of approved make & shade in design

    and pattern as per drawings. The panels shall have

    grooves of 9.5 mm x 9.5 mm at corners with 6mm

    thk wooden lipping around the grooves/or SS

    metallic laminate (1.5 mm thick). The panels andthe groove shall be spirit polished and finished

    with melamine matt coating to an even shade as

    per the approval. Basic Rate of Veneer:Rs-100 per

    sft FOR site & of SS metallic laminate: Rs-140 per

    sft FOR site.

    Sqm. 285.00

    Veneer Box Paneling with flexi ply & MS frame

    work

  • 7/24/2019 Vol II (ICAR Audi Interior 2013)

    26/50

    S.N. DESCRIPTION OF ITEM UNIT QTY AMOUNT in figu

    (Rs.)

    in figures in words

    RATE (in Rs.)

    4.07.2 Providing and fixing Veneer finished wooden Box

    paneling over existing Columns consisting of 12

    mm thick flexi ply, cold pressed with 3.5 mm

    thick veneer of approved make & shade in design

    and pattern as per drawings. The panels shall be

    installed over a tubular MS base frame of 25 mm *

    25 mm as per requirement & have grooves of 9.5mm x 9.5 mm at corners with 6mm thk wooden

    lipping around the grooves/or SS metallic laminate

    (1.5 mm thick). The panels and the groove shall be

    spirit polished and finished with melamine matt

    coating to an even shade as per the approval. Basic

    Rate of Veneer:Rs-100 per sft FOR site & of SS

    metallic laminate: Rs-140 per sft FOR site.

    Sqm. 285.00

    Laminated Box Paneling

    4.07.3 Providing and fixing Laminate finished wooden

    Box paneling over existing Columns consisting of

    12 mm thick Flexi Ply cold pressed with 1.5 mm

    thick Laminate of Approved make & shade indesign and pattern as per drawings. The panels

    shall have grooves of 7.5 mm x 7.5 mm at corners

    with 6mm thk wooden lipping around the

    grooves/or SS laminate as per drawing. The panels

    and the groove shall be spirit polished and finished

    with melamine matt coating to an even shade as

    per the approval of the E-I-C. Basic rate of

    laminate: Rs: 70 per sft FOR site

    Sqm. 142.00

    Wall Paper

    4.08 Providing & Installing of wall paper as per

    approved samples having 20% recycled content by

    weight minimum 10% post-consumer, and meets

    or exceeds all type-II requirements of CCC-W-408A/D and industry voluntary standard CFFA-w-

    101A/D. Weight of minimum 20 to 13.3 oz/ly

    (619 to 452gms/sqm) & having a minimum width

    of 52 to 54". Backing of Osnaburg or approved

    equivalent, Fire safety norms as per Class A

    (ASTM E-84) Tunnel Test, Corner burn test as per

    NFPA 286 & Life safety code NFPA 101. All

    material & adhesive shall be free from Lead,

    Mercury, Cadmium & chromium & have anti

    microbial features. (Note: No extras will be paid

    for overlapping & wastages or any additional

    material required for installation) (Basic cost of

    Wall Paper Upto: Rs.100 per sft FOR site)

    Sqm. 119.00

    Pin-Up Board

    4.09 Providing and fixing PIN-UP BOARD of size as

    per drawing using 12mm thick cellotex board with

    backing of 6mm BWP ply of approved brand with

    hidden second class teakwood margin on all edges

    and with handloom fabric stretched and pasted on

    top of the board (the basic cost of the fabric shall

    be Rs. 1200 per metre). Frame and the backing ply

    shall be fixed to the wall with approved fixing

    arrangement, all incidentals complete as per

    drawings / as directed.

    Sqm. 50.00

  • 7/24/2019 Vol II (ICAR Audi Interior 2013)

    27/50

    S.N. DESCRIPTION OF ITEM UNIT QTY AMOUNT in figu

    (Rs.)

    in figures in words

    RATE (in Rs.)

    Magnetic White board

    4.10 Providing and fixing of magnetic white board of

    approved make scratch resistant matt finish P3

    surface consisting of ceramic steel of thickness

    0.55mm to 0.65 mm, having a weight of 3-4 kgs

    per sqm. The core material shall be of interior

    grade 9mm thickness with density 700 to 800

    k /cum.With a backing of galvanized steel of 0.25 mm

    thickness having approximate weight of 1.96

    kgs/sqm. This entire assembly shall be housed in

    an anodized aluminum extruded section

    conforming to IS-6477 and IS-3965/2673 and

    corners of moulded ABS. The front and back

    surface will be affixed with 10-15 micron silver

    matt satin finish. This should be provided with

    clamp for hanging arrangement with locking

    facility including one set of accessories comprising

    of magnets, magnetic dry markers and magnetic

    4.10.1 4 x 10 (1200mm x 3000mm) Nos 7.00

    4.10.2 4 x 6 (1200mm x 1800mm) Nos 11.00

    4.10.3 3' x 4' (900mm x 1200mm) Nos 9.00

    4.10.4 2' x 4' (600mm x1200mm) Nos 7.00

    4.11 Structural Steel Frame work

    4.11.1 Providing and fixing structural steel frame (for dry

    cladding with 30 mm thick gang saw cut with

    machine cut edges sand stone) on walls at all

    heights using M.S. square/ rectangular tube in the

    required pattern as per architectural drawing,

    including cost of cutting, bending, welding etc.

    The frame work shall be fixed to the wall with the

    help of M.S. brackets/ lugs of angle iron/ flats etc.which shall be welded to the frame and embedded

    in brick wall with cement concrete block 1:2:4 (1

    cement :2 coarse sand :4 graded stone aggregate

    20 mm nominal size) of size 300x230x300 mm,

    including cost of necessary centering and

    shuttering and with approved expansion hold

    fasteners on CC/RCC surface, including drilling

    necessary holes.

    Kg 344.00

    Approved cramps/ pins etc. shall be welded to the

    frame work to support stone cladding, the steel

    work will be given a priming coat of Zinc primer

    as approved by Engineer in- charge and painted

    with two or more coats of epoxy paint (Shopdrawings shall be submitted by the contractor for

    approval before execution). The frame work shall

    be fixed in true horizontal & vertical lines/planes.

    (Only structural steel frame work shall be

    measured for the purpose of payment, stainless

    steel cramps shall be paid for separately and

    nothing extra shall be paid).

  • 7/24/2019 Vol II (ICAR Audi Interior 2013)

    28/50

    S.N. DESCRIPTION OF ITEM UNIT QTY AMOUNT in figu

    (Rs.)

    in figures in words

    RATE (in Rs.)

    4.11.2 Providing and fixing adjustable stainless steel

    cramps of approved quality, required shape and

    size, adjustable with stainless steel nuts, bolts and

    washer (total weight not less than 260 gms), for

    dry stone cladding fixed on frame work at suitable

    location, including making necessary recesses in

    stone slab, drilling required holes etc complete asper direction of the Engineer-in-charge.

    Each 35.00

    Mosaic/Porcelain wall tiles

    4.12 Providing and laying Joint free Mosaic/Porcelain

    especially designed and manufactured wall tiles

    300 x 600mm or as specified by the engineer in

    charge of thickness not less than 9mm of 1st

    quality of approved make in all colors, shades as

    approved laid on 20mm thick cement mortar 1:4

    (1 cement:4 coarse sand) including jointed with

    Laticrete or approved equivalent jointing

    compound of matching shade etc. complete as per

    direction of E-I-C.

    Sqm 365.00

    Gypsum Board Partition (Perforated & Non

    perforated Gypsum Board)

    4.13 Providing and fixing partition Upto ceiling height

    consisting of G.I. frame and required board,

    including providing and fixing of frame work

    made of special section power pressed/ roll form

    G.I. sheet with zinc coating of 120 gms/sqm(both

    side inclusive), consisting of floor and ceiling

    channel 50mm wide having equal flanges of 32

    mm and 0.50 mm thick, fixed to the floor and

    ceiling at the spacing of 610 mm centre to centre

    with dash fastener of 12.5 mm dia meter 50 mm

    length or suitable anchor fastener or metal screws

    with nylon plugs and the studs 48 mm wide havingone flange of 34 mm and other flange 36 mm and

    0.50 mm thick fixed vertically within flanges of

    floor and ceiling channel and placed at a spacing

    of 610 mm centre to centre by 6 mm dia bolts and

    nuts, including fixing of studs along both ends of

    partition fixed flush to wall with suitable anchor

    fastener or metal screws with nylon plugs at

    spacing of 450 mm centre to centre, and fixing of

    boards to both side of frame work by 25 mm long

    dry wall screws on studs, floor and ceiling

    channels at the spacing of 300 mm centre to

    The boards are to be fixed to the frame work with

    joints staggered to avoid through cracks, M.S.

    fixing channel of 99 mm width (0.9 mm thick

    having two flanges of 9.5 mm each) to be providedat the horizontal joints of two boards, fixed to the

    studs using metal to metal flat head screws,

    including jointing and finishing to a flush finish

    with recommended jointing compound, jointing

    tape, angle beads at corners (25 mm x 25 mm x

    0.5 mm), joint finisher and two coats of primer

    suitable for board as per manufacture's

    specification and direction of engineer in charge

    4.13.1 75 mm overall thickness partition with 12.5 mm

    thick double skin fire rated board conforming to

    IS: 2095: art I

    Sqm 30.00

  • 7/24/2019 Vol II (ICAR Audi Interior 2013)

    29/50

    S.N. DESCRIPTION OF ITEM UNIT QTY AMOUNT in figu

    (Rs.)

    in figures in words

    RATE (in Rs.)

    4.13.2 Providing & fixing single layer 12.5 mm thick

    perforated gypsum board wall paneling using

    board of size 1200*2400 mm, with four tapered

    edges, Upto 16% perforation area of board with 12

    mm dia holes (square), backed with acoustic tissue

    having NRC 0.6 to 0.75, screw fixed with drywall

    screws of 25 mm at 300 mm centers. screwed to45 mm channel section 0.4 mm thick having two

    flanges of 18 mm each placed at 600 mm C/C in

    25*25 mm wall angle 0.4 mm thick having two

    flanges of 25 mm each, fixed to floor & ceiling

    with nylon sleeves & steel screws at 610 mm

    centers. Fixing bracket 0.9 mm thick, 29.5 mm

    wide & 195 mm long, fixed to the wall with the

    help of nylon sleeves & steel screws at 900 mm

    C/C to hold the sections in position & level.

    Sqm 508.00

    Square edges of the board to be finished with

    jointing compound, joint paper tape & two coats

    drywall top coats per recommended practice of the

    manufacturer, including providing & fixing of 50

    mm thick resin bounded 24 kg/cum glass woolinsulation fixed to the frame with the help of GI

    wire mesh to improve the NRC etc all complete.

    Zigzag Contours Plaster

    4.14 Providing zigzag contours in cement plaster on the

    existing wall in cement mortar (1:4) 38mm thick

    average (12mm thick to 62mm thick) as shown in

    drawings held in with 28GX12mm GI wire netting

    fixed with nails. The entire plastered surface shall

    be finished with two coats of acrylic emulsion

    black paint over a coat of primer. Entire work to

    be done as per drawing and specifications.

    Sqm 212.00

    Acoustic Plaster Paint

    4.15 Providing & applying K-13 Standard Grade, sound

    absorbing cellulose-base plaster, organic in nature,

    free of asbestos, fiberglass, or manmade mineral

    fibers and treated with fire resistant chemicals,

    sprayed with high pressure equipment to the

    substrate in white color, construction material

    Class B1 according to DIN 4102, to be sprayed at

    an average thickness of 50mm, including

    protection cover for surfaces that are not to be

    sprayed. Clips, hangers, supports, sleeves and

    other attachments to substrate shall be fixed by

    other agencies prior to spray plaster activity

    whereas ducts, piping and other suspended

    equipment shall be placed / fixed after the spray

    activity. All materials shall be supplied in

    unopened containers bearing the name of

    manufacturer, product identification and reference

    to UL testing.

    Sqm 25.00

  • 7/24/2019 Vol II (ICAR Audi Interior 2013)

    30/50

    S.N. DESCRIPTION OF ITEM UNIT QTY AMOUNT in figu

    (Rs.)

    in figures in words

    RATE (in Rs.)

    The manufacturer or the applicator shall provide

    MTC complying material with ASTM E-84 / U. L.

    723, tested at a minimum of 5 thk Class I, Class

    A, Flame Spread: 5, Smoke Development: 5,

    ASTM E-1042, Non corrosive per UMB-80, Bond

    Deflection per ASTM E-759: 6 deflection in 10

    span no spalling or delamination. The plastershall be cured with natural ventilation. The

    applicator / manufacturer shall provide with test

    data that the acoustical plaster gives absorption co-

    efficient NRC 0.95 and meet the individual

    absorption coefficient at 125hz=0.26, at

    250hz=0.68, at 500hz=1.05, at 1khz=1.10, at

    2khz=1.03 at complete octave band.

    5.00 DOORS, WINDOWS, GLAZING AND

    COVERING

    5.01 Glass Partition on "C" channel.

    5.01.1 Providing & Fixing 12 mm thk. Toughened Clear

    Glass partition on aluminum 'C' channel of

    25x25x1mm size with Silicon Sealant filling as

    approved, inclduing making groove of 25 mm x 25

    mm in floor with floor cutting machine, fixing

    aluminium "C" channel in the groove with suitable

    screws and fasteners and work to be completed as

    er the drawin s

    sqm 298.00

    5.01.2 Providing & Fixing 8 mm thk. Toughened Clear

    Glass in windows on aluminum 'C' channel of

    25x25x1mm size with Silicon Sealant filling as

    approved. The work is to be completed by fixing

    the cannel to the required location and then

    lacin the lass.

    sqm 11.00

    5.02 Frameless Glazed Door

    5.02.1 Providing and fixing 12 mm thick frameless

    toughened glass door shutter of approved brand

    and manufacture, including providing and fixing

    top & bottom pivot & spring type fixing

    arrangement and making necessary holes etc. for

    fixing required door fittings, all complete as per

    direction of Engineer-in-charge (Door handle, lock

    and stopper etc. to be paid separately).

    sqm 57.00

    5.03 Film on Glass:

    5.03.1 Providing and fixing antishatter sun film

    (Minimum thickness of 2 mil) on glass for

    Etching effectas per detail design and pattern.

    sqm 183.00

    5.03.2 Providing and fixing frosting film (Minimum

    thickness of 2 mil) in required pattern as per the

    approval, design & Pattern.

    sqm 178.00

    5.04 Glass Door Fittings & Accessories

    Supply and Fixing of following door fittings as per

    selection of the Engineer-in-charge

    5.04.1 SS Door stopper/ buffer floor stop half dome with

    45mm dia with fixing accessories, in satin Chrome

    finish.

    Nos 26.00

  • 7/24/2019 Vol II (ICAR Audi Interior 2013)

    31/50

    S.N. DESCRIPTION OF ITEM UNIT QTY AMOUNT in figu

    (Rs.)

    in figures in words

    RATE (in Rs.)

    5.04.2 Top pivot point: top patch with plastic socket for

    top pivot 15 mm , Satin Stainless Steel finish.

    Nos 26.00

    5.04.3 Over Panel Side Panel Connecting Patch with

    Pivot, with inserts (1 x stop, 2 x blank), Satin

    Stainless Steel finish

    Nos 39.00

    5.04.4 Top & Bottom patch fitting: top patch 15 mm ,

    Satin Stainless Steel finish & bottom patch with

    insert for floor spring spindle, or round pivot 14

    mm . Satin Stainless Steel Finish.

    Nos 39.00

    5.04.5 SS glass door pull handle: back to back with

    350mm CTC, adjustable fixing for glass, wood

    and metal doors in satin stainless steel. The pull

    handles should have supporting washer with raised

    bevelling on the outer surface. Length =450mm,

    25mm dia - SS304

    Nos 26.00

    5.04.6 Heavy duty floor spring with 90 Hold Open: floor

    spring BTS 75V EN 1-4 with std. spindle andcover plate. The floor spring with backcheck and

    adjustable closing speed from 175. With 90 hold

    open. As per EN 1154. Satin stainless steel Finish.

    Nos 26.00

    5.04.7 Patch lock for glazed doors: corner lock, prepared

    for Europrofile cylinder, single throw, bolt

    projection 20 mm including epc both side key

    operation and lock keeper plate, Satin Stainless

    Steel Finish.

    Nos 39.00

    5.04.8 Wall to Glass Clamping Patch: Std with pivot

    insert 15 mm with fixing plate, Satin Stainless

    Steel Finish.

    Nos 26.00

    5.04.9 Glass to Glass Connecting Patch to Wall/Ceiling:

    Universal patch fitting for connection of overpanel

    and sidelight, Std for 12 mm glass, with or with

    out fin on one side, with inserts (1 x stop, 2 x

    blank), Satin Stainless Steel Finish.

    Nos 26.00

    5.04.10 Double Glass Connector: Universal patch fitting

    for connection of overpanel and sidelight, Std for

    12 mm glass, with or with out fin on one side, with

    inserts (1 x stop, 2 x blank), Satin Stainless Steel

    Finish.

    Nos 26.00

    5.05 Providing and fixing ISI marked flush door

    shutters conforming to IS : 2202 (Part I) decorative

    type, core of block board construction with frame

    of 1st class hard wood and well matched teak 3 ply

    veneering with vertical grains or cross bands and

    face veneers on both faces of shutters.

    5.05.1 35 mm thick including ISI marked Stainless Steel

    butt hinges with necessary screws

    sqm 92.00

  • 7/24/2019 Vol II (ICAR Audi Interior 2013)

    32/50

    S.N. DESCRIPTION OF ITEM UNIT QTY AMOUNT in figu

    (Rs.)

    in figures in words

    RATE (in Rs.)

    5.06 Providing and Fixing Cherry/Maple beech wood

    SR (sound resistant) doors made out of

    Marandiwood frame of size 50 x 50 mm at 450

    mm c/c covered with 12 mm thick (in two layers

    of 6 mm each) Superior Quality MDF on both

    sides cold pressed panels made with 3.5 mm thick

    veneer (or as approved by the E-I-C) finish as perrequired design. The door shall be framed with

    Cherry/Maple beach wood of section thickness 72

    x 150 mm all around as per design. The gap of 50

    mm within the door shall be filled up with 50 mm

    thick Fiber Glass wool packed in hessian cloth for

    sound insulation. All natural wood & veneer

    surfaces shall be spirit polished and finished with

    a coat of melamine matt finish.

    Sqm. 155.00

    The door shall have all stainless steel fittings

    including butt hinges (4 nos each panel) of

    approved make stainless steel AISI 316 grade butt

    hinges of size 100x75x2.5 mm with self

    lubricating ball bearing complete with screw and

    satin finish stainless steel AISI 304 grade leverhandle , Cylinder , Closed Body Mortise lock with

    Strike Plate, Heavy Door Closer of approved make

    complete with latch lock, strike plate and screws

    etc. and as per direction of E-I-C.

    5.07 Providing wood work in frames of doors,

    windows, clerestory windows and other frames,

    wrought framed and fixed in position with hold

    fast lugs or with dash fasteners of required dia &

    length ( hold fast lugs or dash fastener shall be

    aid for se aratel .5.07.1 Second class teak wood cum 4.00

    Roller Blinds

    5.08 Providing and Fixing Roller blinds of shade and

    type as given below and of approved make

    comprising of roller tube, clutch, idler, installation

    brackets and bottom weight. Roller tube shall be of

    anodized extruded Aluminum section of min.

    1.0mm thickness and 32mm O.D. Clutch shall be

    of wrap spring design with high strength fiberglass

    reinforced polyester assembly. Clutch mechanism

    shall be crash proof, prevent slippage and shall

    raise and lower smoothly to any desired height.

    Clutch shall never need adjustment.

    5.08.1 With Screen fabric Sqm. 207.00

    5.08.2 With Solar Blinds Sqm. 240.00

    5.09 DOOR FRAME & SHUTTER: Providing &

    Fixing of CBRI tested & TAC approved 77mm

    thick Acoustic cum Fire/Smoke check door of 120

    minutes fire rating with 38dB Noise reduction

    property as per the specification mentioned below:

  • 7/24/2019 Vol II (ICAR Audi Interior 2013)

    33/50

    S.N. DESCRIPTION OF ITEM UNIT QTY AMOUNT in figu

    (Rs.)

    in figures in words

    RATE (in Rs.)

    5.09.1 Supply & Installation of Cherry/Maple Wood Door

    Frame of section 100mm x 75mm with heat

    activated intumescent fire seal strip of size 10mm

    x 4mm Twin Type (Astroflame U.K make or

    approved equivalent) mounted on the door frames

    on all three sides and one coat of anti-termite fire

    retardant primer. Door shutter consisting of 77mmthick door shutter having 38 dB acoustic cum 120

    min. fire rating having infill of 49mm thick resin

    bonded glasswool of 24kg / M3 density with FR

    Acrylic Sealant sandwiched between two 9mm

    thick (Starpan Make or Approved equivalent)

    Calcium Silicate boards a 100% without asbestos,

    Brucite and Meerschaum having a density not less

    than 1150kg/M3 and thermal conductivity 0.14

    W/m* K faced with 3.4mm thick commercial ply

    1mm laminated on both sides with heat activated

    intumescent fire seal strip of size 10mm x 4mm

    mounted in the grooves having hardwood lipping.

    Sqm 114.00

    Including Marshall Acoustic seals around the jamb

    and head on frame rebates, which is adjustable to

    seal for noise, light and smoke for a maximum gap

    of 8mm between frame and shutter.

    Consisting of Drop Seal (2 nos): A medium

    temperature smoke door bottom seal, with an

    extruded siliconsealing component. It is heavy

    duty automatic door bottom seal which is spring

    leaded to lift clear of the floor as soon as the door

    leaf is opened by a few millimeters. The seal is

    operated automatically by pressure against the

    door jamb on the adjusting screw. It seals when

    the door closes and retracts automatically when the

    door is opened. It is self-leveling.

    Astragal Seal (1 NO): Marshall Astragal seal is

    acoustic and smoke astragal design for meeting the

    stiles of rebated double leaf doors. The aluminium

    trim conceals the sealing portion of the seal in

    rebate to provide acoustic properties.

    5.09.2 Door Closer:Supply & Installation of heavy duty

    door closer, CE & EN 1154 certified 2 hrs fire

    rated with 10 years warranty tested to BS 476 Part

    22 and as er a roved make.

    Nos 48.00

    5.09.3 Panic Exit Devices: Supply & Installation of

    single/double leaf panic exit devices, CE & EN

    1125 certified 2 hrs fire rated tested in accordance

    with BS 476 Part 22.5.09.3.1 Single Leaf Panic Bar Nos 4.00

    5.09.3.2 Double Leaf Panic Bar Nos 24.00

    5.09.3.3 Out Side Access Trim: Supply & Installation of

    Out Side Access Trim

    Nos 48.00

    5.09.4 Dead Lock: Supply & Installation of dead lock

    with cylinder, 2 hrs fire rated having 7 years

    mechanical warranty tested to BS 476 Part 22 and

    as tested from CBRI Roorkee.

    Nos 48.00

  • 7/24/2019 Vol II (ICAR Audi Interior 2013)

    34/50

    S.N. DESCRIPTION OF ITEM UNIT QTY AMOUNT in figu

    (Rs.)

    in figures in words

    RATE (in Rs.)

    5.09.5 D-Type Handle:Supply & Installation of stainless

    steel D- Type pull handle of size 200mm long

    19mm dia.

    Pair 48.00

    5.09.6 Hinges: Supply & Installation of 304 grade

    stainless steel ball bearing hinges of size 100mm x

    100mm x 3mm.

    Nos 240.00

    5.10 Providing and cold pressing approved quality &

    shade Veneer (3.5mm thick) on the Panels of

    existing doors including cutting, pasting &

    finishing the doors panels with lacquered polish.

    The panels shall be fixed leaving a precise gap of

    10 mm between two panels. (Basic Rate of

    Veneer=RS.100/- per sft FOR site)

    Sqm 206.00

    5.11 Providing & fixing 18mm thick mirror polished,

    machine cut black granite (galaxy type)

    door/window frame of required width with rebate

    of required size as per approved sample and

    making full round moulding on exposed edgesincluding rubbing, curing etc. complete at all

    levels and as er direction of E-I-C.5.11.1 Door / Window frame 300mm width (with

    necessary groove or overlap required for the

    installation of lass or door anel

    Rmt 295.00

    5.11.2 Moulding of size Upto 40x40mm Rmt 591.00

    5.12 Windows & Shutters

    5.12.1 Sliding Glazed Aluminum Window SGW1

    (Control Room)

    Sqm 20.00

    Providing