2
D3100 Series 800.727.5646 atcdigitec.com Digitec Division 1 VOLTAGE/CURRENT MODELS (D3110/D3112 SERIES): These models include standard voltage and current input types with full scale ranges of ±1,999 and ±19,999. Standard with scaling, relays and analog output. Accuracy .05% of FS ±1 ct. PROCESS MODEL(D3120/D3122 SERIES): This model accepts common 4-20mA signals from standard process transmitters. This meter can also be user configured (via berg jumper) for 0-10V and 1-5V signal inputs. Standard with scaling, 2 relays, excitation and analog output. These models offer 3-1/2 digit (3120) or 4-1/2 digit (D3122) resolution. Accuracy 0.5% FS, ±1 ct. THERMOCOUPLE TEMPERATURE MODEL (D3130/D3132 SERIES): Two models are available in this low-cost series, J and K type thermocouples. Standard with 2 relays and analog output. These models offer 1° (D3130) or 0.1° (D3132) temperature resolution. Selectable °C or °F. The temperature ranges for the D3130 models are: 313X-03 J-148˚ to 1292˚F (-100˚ to +700˚C) 313X-05 K-148˚ to 1999˚F (-100˚ to +1200˚C) Accuracy is ±2˚C or ±4˚F. The meter will flash all digits if the thermocouple opens. STRAIN GAUGE METER (D3140/D3142 SERIES): These models are designed to oper- ate with 20mV input with a +10 volt excitation supplied by the meter. There are two models available with resolutions of 3-1/2 digit (D3140) or 4-1/2-digit (D3142). The sensitivi- ty of the 3140 is 10μV/count and the 3142 is 1μV/count. The 10V @ 120mA excitation supply is capable of powering up to four 350load cells which makes these models ideal for scale applications. Accuracy 0.1% of FS ±1 ct. Standard with scaling, 2 relays, excitation and analog output. Note: Refer to D3700 series for more sophisticated features. TRUE AC RMS METER (D3150/D3152 SERIES): These models are designed to measure the root-mean-square value of complex wave forms. There are 10 ranges to choose from covering the most common inputs. All models are provided with internal volt- age dividers or shunts. The special 5A current range allows direct connection to a current transformer (CT) with a 5A secondary, without requiring a stepdown transformer. Standard with 2 relays and analog output. Accuracy is ±0.1% of reading ±10 ct. RTD TEMPERATURE (D3160/D3162 SERIES): There are two models available in this series (D3160) 1° resolution and (D3162) .1° resolution. Input is 100 platinum 0.00385 alpha. These RTD meters are designed for 2 or 3-wire RTD probes. (Applications requiring a 4-wire connection or non-standard sen- sor curve refer to the D3200 series). If the RTD sensor opens or the wiring becomes faulty the display will flash all digits. The meter is factory configured for the Fahrenheit scale but, it can be re-configured easily in the field for Celsius. Temperature range of -148° to 1472° F (-100° to 800° C). Standard with 2 relays and analog output. AC AVERAGE SENSING (D3170/D3172 SERIES): These low-cost models use a precision op-amp rectifier circuit and are calibrated to measure the RMS value of sinusoidal wave forms. There are 10 ranges to choose from covering the most common inputs. All are provided with internal voltage dividers or shunts. Standard with 2 relays and analog output. Accuracy is ±0.1% of reading ±10 ct. 800.727.5646 atcdigitec.com Digitec Division \ \ \ COMMON SPECIFICATIONS A/D Dual slope A/D with 2.5 reading SEC POWER 115/230 VAC powered TEMPERATURE RATING 32° to 122°F (0° to 50°C) CUTOUT 1/8 DIN (92 x 45mm) DEPTH 4.04" (102.5mm) WEIGHT 16 oz. Bright, long lasting LED display, 0.56" LED 2 Relay Outputs 4-20mA or 0-10V analog output (user selection) Drip-proof and dust tight Front Cover NEMA 12 Compact 1/8 DIN case Plug in screw terminal connectors Wide range of engineering units Slot on inside of front panel for displaying unit of measure from furnished decal sheet Excitation supplies of 10 Volt DC @ 120mA, maximum of +24 Volt @ 50mA (user selectable) standard on Strain Gauge and Process Models. SEVEN MODELS • Voltage/Current • Process Thermocouple (J & K) • RTD True AC RMS Voltage/Current AC Average Voltage/Current Strain Gauge OPTIONS Black Case Custom Calibration NEMA 4X Cover

VOLTAGE/CURRENT MODELS (D3110/D3112 SERIES ......800.727.5646 atcdigitec.com Digitec Division D3100 Series 1 VOLTAGE/CURRENT MODELS (D3110/D3112 SERIES):These models include standard

  • Upload
    others

  • View
    13

  • Download
    0

Embed Size (px)

Citation preview

Page 1: VOLTAGE/CURRENT MODELS (D3110/D3112 SERIES ......800.727.5646 atcdigitec.com Digitec Division D3100 Series 1 VOLTAGE/CURRENT MODELS (D3110/D3112 SERIES):These models include standard

D3100 Series800.727.5646 atcdigitec.com Digitec Division

1

VOLTAGE/CURRENT MODELS (D3110/D3112 SERIES): These modelsinclude standard voltage and current input types with full scale ranges of±1,999 and ±19,999. Standard with scaling, relays and analog output.Accuracy .05% of FS ±1 ct.

PROCESS MODEL(D3120/D3122 SERIES): This model accepts common4-20mA signals from standard process transmitters. This meter can alsobe user configured (via berg jumper) for 0-10V and 1-5V signal inputs.Standard with scaling, 2 relays, excitation and analog output. Thesemodels offer 3-1/2 digit (3120) or 4-1/2 digit (D3122) resolution.Accuracy 0.5% FS, ±1 ct.

THERMOCOUPLE TEMPERATURE MODEL (D3130/D3132 SERIES): Twomodels are available in this low-cost series, J and K type thermocouples.Standard with 2 relays and analog output. These models offer 1° (D3130) or0.1° (D3132) temperature resolution. Selectable °C or °F. The temperatureranges for the D3130 models are:

313X-03 J-148˚ to 1292˚F (-100˚ to +700˚C)313X-05 K-148˚ to 1999˚F (-100˚ to +1200˚C)

Accuracy is ±2˚C or ±4˚F. The meter will flash all digits if the thermocouple opens.

STRAIN GAUGE METER (D3140/D3142 SERIES): These models are designed to oper-ate with 20mV input with a +10 volt excitation supplied by the meter. There are twomodels available with resolutions of 3-1/2 digit (D3140) or 4-1/2-digit (D3142). The sensitivi-ty of the 3140 is 10µV/count and the 3142 is 1µV/count. The 10V @ 120mA excitation supply iscapable of powering up to four 350Ω load cells which makesthese models ideal for scale applications. Accuracy 0.1% of FS ±1ct. Standard with scaling, 2 relays, excitation and analog output.

Note: Refer to D3700 series for more sophisticated features.

TRUE AC RMS METER (D3150/D3152 SERIES): These modelsare designed to measure the root-mean-square value of complexwave forms. There are 10 ranges to choose from covering themost common inputs. All models are provided with internal volt-age dividers or shunts. The special 5A current range allows directconnection to a current transformer (CT) with a 5A secondary,without requiring a stepdown transformer. Standard with 2 relaysand analog output. Accuracy is ±0.1% of reading ±10 ct.

RTD TEMPERATURE (D3160/D3162 SERIES): There are twomodels available in this series (D3160) 1° resolution and (D3162).1° resolution. Input is 100 Ω platinum 0.00385 alpha.

These RTD meters are designed for 2 or 3-wire RTD probes.(Applications requiring a 4-wire connection or non-standard sen-sor curve refer to the D3200 series).

If the RTD sensor opens or the wiring becomes faulty the displaywill flash all digits. The meter is factory configured for theFahrenheit scale but, it can be re-configured easily in the field forCelsius. Temperature range of -148° to 1472° F (-100° to 800° C).Standard with 2 relays and analog output.

AC AVERAGE SENSING (D3170/D3172 SERIES): These low-costmodels use a precision op-amp rectifier circuit and are calibratedto measure the RMS value of sinusoidal wave forms. There are 10ranges to choose from covering the most common inputs. All areprovided with internal voltage dividers or shunts. Standard with 2relays and analog output. Accuracy is ±0.1% of reading ±10 ct.

800.727.5646 atcdigitec.com Digitec Division

\ \ \COMMON SPECIFICATIONSA/D Dual slope A/D with 2.5 reading SECPOWER 115/230 VAC poweredTEMPERATURERATING 32° to 122°F (0° to 50°C)

CUTOUT 1/8 DIN (92 x 45mm)DEPTH 4.04" (102.5mm)WEIGHT 16 oz.

• Bright, long lasting LED display, 0.56" LED

• 2 Relay Outputs

• 4-20mA or 0-10V analog output (user selection)

• Drip-proof and dust tight Front Cover NEMA 12

• Compact 1/8 DIN case

• Plug in screw terminal connectors

• Wide range of engineering units

• Slot on inside of front panel for displaying unit of measure fromfurnished decal sheet

• Excitation supplies of 10 Volt DC @ 120mA, maximum of +24Volt @ 50mA (user selectable) standard on Strain Gauge andProcess Models.

SEVEN MODELS• Voltage/Current• Process• Thermocouple (J & K)• RTD• True AC RMS

Voltage/Current• AC Average

Voltage/Current• Strain Gauge

OPTIONS

• Black Case

• Custom Calibration

• NEMA 4X Cover

Page 2: VOLTAGE/CURRENT MODELS (D3110/D3112 SERIES ......800.727.5646 atcdigitec.com Digitec Division D3100 Series 1 VOLTAGE/CURRENT MODELS (D3110/D3112 SERIES):These models include standard

Digitec Division atcdigitec.com 800.727.5646

2

Digitec Division atcdigitec.com 800.727.5646

MODEL NUMBER > > > > > > D 3 1

10

B

3-1/2 Digit Voltage/Current4-1/2 Digit Voltage/Current 12

3-1/2 Digit Process Model 204-1/2 Digit Process Model 22

3-1/2 Digit Thermocouple Temp. 304-1/2 Digit Thermocouple Temp. 32

3-1/2 Digit Strain Gage 404-1/2 Digit Strain Gage 42

3-1/2 Digit True AC RMS Meter 504-1/2 Digit True AC RMS Meter 52

3-1/2 Digit RTD Temperature 604-1/2 Digit RTD Temperature 623-1/2 Digit AC AVG Sensing 704-1/2 Digit AC AVG Sensing 72

Input Rates*See Range Chart

OptionsBlack Case

Prescaled FNEMA 4 Cover with Gasket N

230 VAC Power S*D3120, D3122, D3140 & D3142 do not include range option.

\ \ \RANGE CHART3-1/2 Digit 4-1/2 Digit Input Ranges

D3110-01 D3112-01 -199.9(9)mV to +199.9(9)mVD3110-02 D3112-02 -1.999(9)V to +1.999(9)VD3110-03 D3112-03 -19.99(9)V to +19.99(9)VD3110-04 D3112-04 -199.9(9)V to +199.9(9)VD3110-05 D3112-05 -650(.0)V to +650(.0)VD3110-11 D3112-11 -199.9(9)uA to +199.9(9)uAD3110-12 D3112-12 -1.999(9)mA to +1.999(9)mAD3110-13 D3112-13 -19.99(9)mA to +19.99(9)mAD3110-14 D3112-14 -199.9(9)mA to +199.9(9)mAD3110-15 D3112-15 -1.999(9)A to +1.999(9)A

D3120 D3122 4-20 mA or 0-10 VDC ProgressD3140 D3142 Strain Gauge Input

D3130-03 D3132-03 1° resolution, JD3130-05 D3132-05 0.1° resolution, KD3150-01 D3152-01 0V to 199.9(9)mVD3150-02 D3152-02 0V to 1.999(9)VD3150-03 D3152-03 0V to 19.99(9)VD3150-04 D3152-04 0V to 199.9(9)VD3150-05 D3152-05 0V to 650(.0)VD3150-11 D3152-11 0µA to 199.9(9)µAD3150-12 D3152-12 0mA to 1.999(9)mAD3150-13 D3152-13 0mA to 19.99(9)mAD3150-14 D3152-14 0mA to 199.9(9)mAD3150-15 D3152-15 0A to 1.999(9)AD3150-16 D3152-16 0A to 5.00(0)AD3170-01 D3172-01 0V to 199.9(9)mVD3170-02 D3172-02 0V to 1.999(9)VD3170-03 D3172-03 0V to 19.99(9)VD3170-04 D3172-04 0V to 199.9(9)VD3170-05 D3172-05 0V to 650(.0)VD3170-11 D3172-11 0µA to 199.9(9)µAD3170-12 D3172-12 0mA to 1.999(9)mAD3170-13 D3172-13 0mA to 19.99(9)mAD3170-14 D3172-14 0mA to 199.9(9)mAD3170-15 D3172-15 0A to 1.999(9)AD3170-16 D3172-16 0A to 5.00(0)AD3170-17 D3172-17 0-10A AC