2.1
25.8sq.m
Becks Room
Ceiling to remain
2.2
8.9sq.m
Seamus Room
Ceiling to remain
2.3
27.6sq.m
Main Bedroom
Ceiling replaced
2.7
4.3sq.m
Hallway
Ceiling to remain
2.5
6.71sq.m
Bathroom
Ceiling replaced
2.4
13.25sq.m
Eoins Room
Ceiling to remain
2.6
16.7sq.m
Stairs Area
Ceiling replaced
2.8
4.3sq.m
Hallway
Ceiling replaced
switch point
2-way switch point
ceiling pendant light
external bulkhead light (vandal resisting fitting)
bathroom ceiling light 60w 225mm drum white trim.
switched 13amp power socket outlet
twin switched 13amp power socket outlet
2 row MCB consumer unit (2250mm to top of unit)
45amp cooker unit
immersion switch
TV socket outlet
ESB meter cabinet
time clock heating system
circulating pump heating system
smoke alarm
double immersion group
external porch light & globe (vandal resisting fitting)
LEGEND
heat detector
light switches 1100mm above floor level
power socket outlets 450mm above floor level
3 3 pole switch isolator
Data Pointsdata
LED spolight
wall lightWHB Light
Mechanical Extract Fan
LandingGR
OU
ND
FLO
OR
LAYO
UT
EXIS
TIN
G SE
RVIC
ES- -
Tend
er S
tage
13
61
0
10810
12
50
0
12
45
0
11
38
0
extended roof line to 450mm
as shown
hidden line is the assumed
line of the existing roof prior
to flat roof extension works.
450mm extended roof with
surface water gutter to tie into
existing rainwater pipe.
new hip sections flashed into
position to the rear of
chimneys to throw rainwater
away either direction.
new hip sections flashed into
position to the rear of
chimneys to throw rainwater
away either direction.
Any SVP or rainwater
downpipes to be adjusted to
allow for extended soffit
New ogee style gutter
connected into existing
downpipe.
Flash around existing
chimney using suppliers
details.
GRO
UN
D FL
OO
R LA
YOU
T EX
ISTI
NG
SERV
ICES
- -
Tend
er S
tage
10750
35805570
6090 4100
560
9670
2601
3137
8
9
4
1
2
6
5
690
790
125
7
5
2
3
7
5
2
520 290
FFL - First Floor FFL - First Floor
2475
4
5
0
100
3
3
°
To Note:All dimensions to be checked on site. No dimensions to be scaled from drawings. This drawing to be read in conjunction with therelevant specifications, documention and relevant drawings supplied by consultants. All queries should be raised with the Project Supervisor.
TENDER STAGE ONLY
CLIENT
Project:
JOB NO:DATE:SCALE:
DRAWN:SHEET SIZE:
DRAWING NO:
DRAWING:
REV NO:
REV DATE DESCRIPTION DRAWN
© COPYRIGHT
BCF Architects
CloncannonLower, Mountmellick, County Laois.Tel: 057 8679757 e-mail:[email protected] Herberton, 26 St. James Walk, Rialto, Dublin 8.Tel: 01 - 5352674 e-mail:[email protected]
Mr. Ray & Eilish Ryan
14.77
10/19/2016 2:19 PM
As Shown
Bcf Architects
A3
Proposed refurbishment of existing pitched and flat roof to Coolnabacca House, Stradbally,
County Laois.
14.77.05.003 - Cross Section
C:\Users\Bcf Architects\Dropbox (BCF Architects)\00.01 - BCF Architects Current Projects\14.77 - Ray Ryan\14.77 - Ray Ryan Tender Dwg_recover_recover_recover_recover_recover_recover_recover_recover.dwg
GROUND FLOOR LAYOUT EXISTING SERVICES--
Tend
er S
tage
BAUDER THERMOPLAN FPO SYSTEM, SILVER GREY RAL 7001.
BITUMEN IMPREGNATED HUNTON FIBREBOARD, 120mm TAPERED
THERMAL INSULATION XTRA-THERM XF 160068 WITH A MINIMUM
THERMAL CONDUCTIVITY OF 0.022(W/mK).
2mm VAPOUR CONTROL LAYER LAPPED AND SEALED TO ACHIEVE
AN AIR TIGHTNESS OF 3m3 OR LESS @ 50 PASCAL'S OF PRESSURE
TO APPLY.
89
120
EXISTING WALL - MAKE UP UNKNOWN
EXISTING 150mm CEILING ZONE RETAINED FOR SERVICES
ISOVER AIR TIGHTNESS MEMBRANE TAPED TO WALLS WITH
GYPROC OR EQUAL APPROVED 50MM INSULATED BOARD,
SKIMMED AND PAINTED WHITE.
ISOVER AIR TIGHTNESS MEMBRANE TAPED TO WALLS WITH
GYPROC OR EQUAL APPROVED 50MM INSULATED BOARD,
SKIMMED AND PAINTED WHITE.
ADDITIONAL BRIDGING TO BE ALLOWED IN THE EXISTING 150MM
CEILING ZONE
3
3
°
"TYVEK" OR EQUAL APPROVED PROTECT FELT, LAID WITH MIN
150mm HORIZONTAL LAP, AND 100mm VERTICAL LAP ON EXISTING
ROOF TRUSSES.
"GLIDEVALE RV401" ROOF VENTILATOR AT 1500mm CENTRES OR
SIMILAR APPROVED.
EXISTING TILES/ SLATES TO BE RE-LAID TO TREATED TIMBER 50mm
x 37.5mm BATTENS
LEAD FLASHING WITH 8mm GUN GRADE SEALANT 0100 OR SIMILAR
APPROVED, TO ACHIEVE AIR SEAL OR CONTINOUS DPC WITH
MINIMUM 4 STRIPS OF POLY-BUTYL RUBBER TAPE.
ADDITIONAL 3mm PARALON BASE SHEET LAYER
TO JUNCTION BETWEEN FLAT ROOF & PITCH ROOF.
ANGLE FILLET
100MM XTRA-THERM OR EQUAL APPROVED HD INSULATION BOARD
FITTED BETWEEN EXISTING ROOF RAFTERS AT JUNCTION A - B AS
SHOWN. NO GAPS BETWEEN BOARDS AND JOISTS. ALL GAPS FILLED.
THIS ROOF JUNCTION IS UNKNOWN. FURTHER ON-SITE
INVESTIGATION REQUIRED. CONTRACTOR TO ALLOW FOR THE
ABOVE WHEN PRICING.
300MM QUILT INSULATION TO MAIN ATTIC AREA AS SHOWN.
To Note:All dimensions to be checked on site. No dimensions to be scaled from drawings. This drawing to be read in conjunction with therelevant specifications, documention and relevant drawings supplied by consultants. All queries should be raised with the Project Supervisor.
TENDER STAGE ONLY
CLIENT
Project:
JOB NO:DATE:SCALE:
DRAWN:SHEET SIZE:
DRAWING NO:
DRAWING:
REV NO:
REV DATE DESCRIPTION DRAWN
© COPYRIGHT
BCF Architects
CloncannonLower, Mountmellick, County Laois.Tel: 057 8679757 e-mail:[email protected] Herberton, 26 St. James Walk, Rialto, Dublin 8.Tel: 01 - 5352674 e-mail:[email protected]
Mr. Ray & Eilish Ryan
14.77
10/19/2016 2:19 PM
As Shown
Bcf Architects
A3
Proposed refurbishment of existing pitched and flat roof to Coolnabacca House, Stradbally,
County Laois.
14.77.05.004 - Detail A
C:\Users\Bcf Architects\Dropbox (BCF Architects)\00.01 - BCF Architects Current Projects\14.77 - Ray Ryan\14.77 - Ray Ryan Tender Dwg_recover_recover_recover_recover_recover_recover_recover_recover.dwg
GROUND FLOOR LAYOUT EXISTING SERVICES--
Tend
er S
tage
450
AN AIR TIGHTNESS OF 3m3 OR LESS @ 50 PASCAL'S OF PRESSURE
18mm EXTERNAL GRADE WBP PLYWOOD SHEET.
150
89
WELD AREA
AT 250mm CENTRES
MECHANICAL FIXING
BAUDER PRE-FORMED METAL TRIM
METAL COVER FLASHING (BY OTHERS)
(SPF TYPE SCREW)
TIMBER BATTEN
ISOVER AIR TIGHTNESS MEMBRANE TAPED TO WALLS WITH
GYPROC OR EQUAL APPROVED 50MM INSULATED BOARD,
SKIMMED AND PAINTED WHITE.
BAUDER THERMOPLAN FPO SYSTEM, SILVER GREY RAL 7001.
BITUMEN IMPREGNATED HUNTON FIBREBOARD, 120mm TAPERED
THERMAL INSULATION XTRA-THERM XF160068 WITH A MINIMUM
THERMAL CONDUCTIVITY OF 0.022(W/mK).
2mm VAPOUR CONTROL LAYER LAPPED AND SEALED TO ACHIEVE
AN AIR TIGHTNESS OF 3m3 OR LESS @ 50 PASCAL'S OF PRESSURE
TO APPLY.
EXISTING WALL - MAKE UP UNKNOWN
285
JOINTING TAPE
BLACK uPVC FASCIA
& SOFFIT AS SHOWN
RAINWATER GUTTER
XTRA-THERM HD INSULATION OR EQUAL APPROVED. FIT INSULATION
OVER WALL TOP WITHIN GABLE LADDER. FULLY FILL VOID,
ENSURING THAT INSULATION IS INSTALLED TIGHTLY BETWEEN
JOISTS AND IS IN CONTACT WITH ROOF DECK. A MIN R-VALUE OF
5.00M2 K/W IS REQ.
To Note:All dimensions to be checked on site. No dimensions to be scaled from drawings. This drawing to be read in conjunction with therelevant specifications, documention and relevant drawings supplied by consultants. All queries should be raised with the Project Supervisor.
TENDER STAGE ONLY
CLIENT
Project:
JOB NO:DATE:SCALE:
DRAWN:SHEET SIZE:
DRAWING NO:
DRAWING:
REV NO:
REV DATE DESCRIPTION DRAWN
© COPYRIGHT
BCF Architects
CloncannonLower, Mountmellick, County Laois.Tel: 057 8679757 e-mail:[email protected] Herberton, 26 St. James Walk, Rialto, Dublin 8.Tel: 01 - 5352674 e-mail:[email protected]
Mr. Ray & Eilish Ryan
14.77
10/19/2016 2:19 PM
As Shown
Bcf Architects
A3
Proposed refurbishment of existing pitched and flat roof to Coolnabacca House, Stradbally,
County Laois.
14.77.05.005 - Detail B
C:\Users\Bcf Architects\Dropbox (BCF Architects)\00.01 - BCF Architects Current Projects\14.77 - Ray Ryan\14.77 - Ray Ryan Tender Dwg_recover_recover_recover_recover_recover_recover_recover_recover.dwg
GROUND FLOOR LAYOUT EXISTING SERVICES--
Tend
er S
tage
Rev 1 dated 4.10.11
Bauder Limited Bauder Limited 70 Landseer Road, Ipswich , Suffolk England IP3 0DH O’Duffy Centre, Carrickmacross, Co. Monaghan Ireland T: +44 (0)1473 257671 E: [email protected] T: +353 (0)42 9692 333 E: [email protected] bauder.co.uk bauder.ie
BAUDER SYNTHETIC SINGLE PLY ROOF SYSTEMS
General Maintenance The following procedure should be carried out at twice yearly intervals (Spring & Autumn) in order to ensure that the roof is maintained in first class condition, and that any potential problems are identified at an early stage.
Ensure safe access can be gained to the roof and that relevant Health and Safety procedures are followed.
Clear all debris from the roof surface, rainwater outlets, chutes, gutters etc. Debris must be removed from the roof and not simply flushed down rainwater pipes
Cut back tree limbs that overhang the roof to give a 1 metre clearance outside the roof edge. This will significantly reduce blockage of drainage ways due to fallen leaves.
Ensure that all rainwater pipes are free from blockages and that water flows freely through them.
Remove any vegetation growth that may have occurred, taking care not to damage the waterproofing.
Ensure that any protective metal flashings or termination bars remain securely fixed and in place.
Examine all mastic sealant and mortar pointing for signs of degradation, and repair/replace as necessary.
Where promenade tiles or pavers are in use, ensure that they remain in position, secure and in good condition.
Ensure that any items of plant/equipment that may have been introduced to the roof are sited on a suitable slab, with additional surface protection beneath, and that any fixings that may have been used to secure them, do not penetrate the waterproofing.
The Building owner should keep a record of all inspections and maintenance carried out on the roof. Any signs of damage or degradation should be reported to Bauder Limited immediately, so that arrangements can be made for remedial work to be carried out if necessary.
Thermoplan System
ADHERED SINGLE PLY FPO SOLUTION The Bauder Thermoplan FPO membrane was introduced in the UK in
2003 to complement our green roof systems by providing an
environmentally friendly single ply membrane. A comprehensive range of
guarantees are available for this system.
Thermoplan T-SV is our stocked product at 2mm, with other thicknesses available for specific project types. The product can be easily adhered to glass tissue faced insulation using the specialist Bauder Full Bond Contact Adhesive. BauderPIR Flatboard Insulation is fully compatible with the Thermofol membrane. It is a PIR glass tissue faced insulation which is thermally efficient, light weight, fire resistant and zero ODP rated. As an alternative, BauderPIR Tapered Insulation can be used to provide improved drainage falls. Bauder Vapour Barriers Bauder manufactures a range of Torch on and Self Adhesive bituminous vapour barriers. All of these types of product can be used within a Thermoplan adhered system and a recommendation can be made according to cost and project programme.
When to Specify This adhered system is ideally suited for a concrete deck on either new build or refurbishment. Especially where the concrete deck cannot be drilled due to having a high proportion of stone or where the deck structure may be compromised by the drilling. The Bauder Thermoplan system has been fully tested to ensure compliance with national building codes and has been tested by both BBA and Factory Mutual.
Product Thickness (mm) Weight (Kg/m²) Thermoplan
T-SV 20 2 2.3
BauderPIR Flatboard Insulation
140* 3.6
BauderTHERM DS1 DUO Vapour Barrier
3.5 4.5
Totals 145.5 10.4
BAUDERPIR FLATBOARD INSULATION Thickness (mm) Approx. ‘U’ value (W/m²K) Weight (Kg/m²)
120 0.20 3.6
140 0.18 4.2
160 0.16 4.8
180 0.13 5.4
Bauder Total Roof System
* Example insulation thickness shown above, achieves a typical ‘U’ value
of 0.18W/m²K. The table below gives a comparison of the thicknesses
needed to achieve U value requirements on a 18mm plywood deck.
Thermoplan System
Weight Loading
U Values
Thermoplan System
MECHANICALLY FIXED SINGLE PLY SOLUTION The Bauder Thermoplan FPO membrane was introduced in the UK in
2003 to complement the Bauder Green Roof Systems by providing an
environmentally friendly single ply membrane. A comprehensive
range of guarantees are available for this system.
Thermoplan T-SV is our stocked product with 1.5mm thick membrane, although other thicknesses are available for specific project types. The product is reinforced with a pre coated polyester cross weaved matting providing high tear resistance that is required from a mechanically fastened membrane.
BauderPIR FA-TE Insulation is fully compatible with the Thermoplan membrane as well as being thermally efficient, lightweight, fire resistant and zero OPP rated. As an alternative, Bauder PIR Tapered Insulation can be used to provide improved drainage falls.
Bauder Vapour Barriers or VCL Bauder manufactures a range of torch bonded or self-adhesive bituminous vapour barriers and loose laid vapour control layers, which can all be used within a Thermoplan mechanically fastened system.
When to Specify The mechanically fastened system is ideally suited for metal and timber deck constructions. It possesses outstanding performance where there is a high risk of wind uplift and provides a secure and economic installation. The system has been fully tested to ensure compliance with national building codes and tested by both BBA and Factory Mutual.
Product Thickness (mm) Weight (Kg/m²) Thermoplan
T-SV 20 2.0 2.3
BauderPIR FA-TE Insulation
120* 3.6
Bauder VB 20 Vapour Barrier
0.2 0.19
Totals 122.2 6.09
BAUDER PIR FA-TE INSULATION Thickness (mm) Approx. ‘U’ value (W/m²K) Weight (Kg/m²)
110* 0.19 3.3
120 0.17 3.6
130* 0.16 3.9
140 0.15 4.2
150* 0.14 4.5
160 0.13 4.8
170* 0.12 5.1
180* 0.12 5.4
190* 0.11 5.7
200* 0.11 6.0
Bauder Total Roof System
* Example insulation thickness shown above, achieves a typical ‘U’ value
of 0.17W/m²K. The table below gives a comparison of the thicknesses
needed to achieve U value requirements on a 18mm plywood deck.
Thermoplan System
Weight Loading
U Values
* Denotes that this thickness is only available in quantities over 1000m²