32
Wall Mounted Type FXAQ-PVJU EDUS391100A-F6 202101 Engineering Data 60 Hz

Wall Mounted Type - Daikin Comfort

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Wall Mounted TypeFXAQ-PVJU

EDUS391100A-F6202101

Engineering Data

60 Hz

1

FXAQ-PVJU EDUS391100A-F6

Table of Contents

1. Specifications .............................................................................................22. Dimensions .................................................................................................53. PipingDiagrams .........................................................................................84. WiringDiagrams .........................................................................................95. ElectricCharacteristics ............................................................................. 116. SafetyDevicesSetting .............................................................................127. CapacityTables ........................................................................................13

7.1 CoolingCapacityatTe:43°F(6°C) .................................................137.2 HeatingCapacity .............................................................................137.3 CorrectionFactorforCoolingCapacityatTe:48°F(9°C) ...............13

8. AirVelocityandTemperatureDistributions(ReferenceData) ..................148.1 CoolingMode ..................................................................................148.2 HeatingMode ..................................................................................19

9. SoundLevels(ReferenceData) ...............................................................24

2

FXAQ-PVJU EDUS391100A-F6

1. Specifications

Wall mounted type

Model FXAQ07PVJU FXAQ09PVJUPowersupply 1phase,208/230V,60Hz 1phase,208/230V,60Hz1,3Coolingcapacity Btu/h 7,500 9,5002,3Heatingcapacity Btu/h 8,500 10,500Casing/Color White(3.0Y8.5/0.5) White(3.0Y8.5/0.5)Dimensions:(H×W×D) in. 11-3/8×31-1/4×9-1/4 11-3/8×31-1/4×9-1/4Coil(crossfincoil)

Rows×Stages×FPI 2×14×17 2×14×17Facearea ft² 1.73 1.73

Fan

Model QCL9661M QCL9661MType Crossflowfan CrossflowfanMotoroutput W 40 40Airflowrate(H/L) cfm 260/160 280/175Drive Directdrive Directdrive

Temperaturecontrol Microprocessorthermostatforcoolingandheating Microprocessorthermostatforcoolingandheating

Soundabsorbingthermalinsulationmaterial Foamedpolystyrene/Foamedpolyethylene Foamedpolystyrene/Foamedpolyethylene

Airfilter Resinnet(washable) Resinnet(washable)4Soundpressurelevel(referencedata)(H/L) dBA 36/31 37/31

Weight lbs 26 26

Pipingconnections

Liquidpipes in. f1/4(flareconnection) f1/4(flareconnection)Gaspipes in. f1/2(flareconnection) f1/2(flareconnection)

Drainpipe in. VP13(externaldia.11/16,internaldia.1/2)

VP13(externaldia.11/16,internaldia.1/2)

Safetydevices Fuse FuseRefrigerantcontrol Electronicexpansionvalve ElectronicexpansionvalveConnectableoutdoorunit R410AVRVseries R410AVRVseries

StandardaccessoriesOperationmanual,Installationmanual,Installationpanel,Paperpatternforinstallation,Insulation

tape,Insulationtube,Clamps,Screws

Operationmanual,Installationmanual,Installationpanel,Paperpatternforinstallation,Insulation

tape,Insulationtube,Clamps,Screws

Note:1. Nominalcoolingcapacitiesarebasedonthefollowingconditions:

Returnairtemperature:80°FDB,67°FWB Outdoortemperature:95°FDB Equivalentrefrigerantpipinglength:25ft(horizontal)

2. Nominalheatingcapacitiesarebasedonthefollowingconditions: Returnairtemperature:70°FDB. Outdoortemperature:47°FDB,43°FWB Equivalentrefrigerantpipinglength:25ft(horizontal)

3. Capacitiesarenet,includingadeductionforcooling(anadditionforheating)forindoorfanmotorheat.4. Anechoicchamberconversionvalue,measuredunderJISconditions.Duringactualoperation,

thesevaluesmaybehigherasaresultofinstallationconditions.

C:3D075572A

3

FXAQ-PVJU EDUS391100A-F6

Wall mounted type

Model FXAQ12PVJU FXAQ18PVJUPowersupply 1phase,208/230V,60Hz 1phase,208/230V,60Hz1,3Coolingcapacity Btu/h 12,000 18,0002,3Heatingcapacity Btu/h 13,500 20,000Casing/Color White(3.0Y8.5/0.5) White(3.0Y8.5/0.5)Dimensions:(H×W×D) in. 11-3/8×31-1/4×9-1/4 11-3/8×41-3/8×9-1/4

Coil(crossfincoil)

Rows×Stages×FPI 2×14×17 2×14×17Facearea ft² 1.73 2.29

Fan

Model QCL9661M QCL9686MType Crossflowfan CrossflowfanMotoroutput W 40 43Airflowrate(H/L) cfm 290/180 500/400Drive Directdrive Directdrive

Temperaturecontrol Microprocessorthermostatforcoolingandheating MicroprocessorthermostatforcoolingandheatingSoundabsorbingthermalinsulationmaterial Foamedpolystyrene/Foamedpolyethylene Foamedpolystyrene/Foamedpolyethylene

Airfilter Resinnet(washable) Resinnet(washable)4Soundpressurelevel(referencedata)(H/L) dBA 38/31 43/37

Weight lbs 26 31

Pipingconnections

Liquidpipes in. f1/4(flareconnection) f1/4(flareconnection)Gaspipes in. f1/2(flareconnection) f1/2(flareconnection)

Drainpipe in. VP13(externaldia.11/16,internaldia.1/2)

VP13(externaldia.11/16,internaldia.1/2)

Safetydevices Fuse FuseRefrigerantcontrol Electronicexpansionvalve ElectronicexpansionvalveConnectableoutdoorunit R410AVRVseries R410AVRVseries

StandardaccessoriesOperationmanual,Installationmanual,Installationpanel,Paperpatternforinstallation,Insulation

tape,Insulationtube,Clamps,Screws

Operationmanual,Installationmanual,Installationpanel,Paperpatternforinstallation,Insulation

tape,Insulationtube,Clamps,Screws

Note:1. Nominalcoolingcapacitiesarebasedonthefollowingconditions:

Returnairtemperature:80°FDB,67°FWB Outdoortemperature:95°FDB Equivalentrefrigerantpipinglength:25ft(horizontal)

2. Nominalheatingcapacitiesarebasedonthefollowingconditions: Returnairtemperature:70°FDB. Outdoortemperature:47°FDB,43°FWB Equivalentrefrigerantpipinglength:25ft(horizontal)

3. Capacitiesarenet,includingadeductionforcooling(anadditionforheating)forindoorfanmotorheat.4. Anechoicchamberconversionvalue,measuredunderJISconditions.Duringactualoperation,

thesevaluesmaybehigherasaresultofinstallationconditions.

C:3D075572A

4

FXAQ-PVJU EDUS391100A-F6

Wall mounted type

Model FXAQ24PVJUPowersupply 1phase,208/230V,60Hz1,3Coolingcapacity Btu/h 24,0002,3Heatingcapacity Btu/h 26,500Casing/Color White(3.0Y8.5/0.5)Dimensions:(H×W×D) in. 11-3/8×41-3/8×9-1/4

Coil(crossfincoil)

Rows×Stages×FPI 2×14×17Facearea ft² 2.29

Fan

Model QCL9686MType CrossflowfanMotoroutput W 43Airflowrate(H/L) cfm 635/470Drive Directdrive

Temperaturecontrol MicroprocessorthermostatforcoolingandheatingSoundabsorbingthermalinsulationmaterial Foamedpolystyrene/Foamedpolyethylene

Airfilter Resinnet(washable)4Soundpressurelevel(referencedata)(H/L) dBA 47/41

Weight lbs 31

Pipingconnections

Liquidpipes in. f3/8(flareconnection)Gaspipes in. f5/8(flareconnection)

Drainpipe in. VP13(externaldia.11/16,internaldia.1/2)

Safetydevices FuseRefrigerantcontrol ElectronicexpansionvalveConnectableoutdoorunit R410AVRVseries

Standardaccessories Operationmanual,Installationmanual,Installationpanel,Paperpatternforinstallation,Insulationtape,Insulationtube,Clamps,Screws

Note:1. Nominalcoolingcapacitiesarebasedonthefollowingconditions:

Returnairtemperature:80°FDB,67°FWB Outdoortemperature:95°FDB Equivalentrefrigerantpipinglength:25ft(horizontal)

2. Nominalheatingcapacitiesarebasedonthefollowingconditions: Returnairtemperature:70°FDB. Outdoortemperature:47°FDB,43°FWB Equivalentrefrigerantpipinglength:25ft(horizontal)

3. Capacitiesarenet,includingadeductionforcooling(anadditionforheating)forindoorfanmotorheat.4. Anechoicchamberconversionvalue,measuredunderJISconditions.Duringactualoperation,

thesevaluesmaybehigherasaresultofinstallationconditions.

C:3D075572A

5

FXAQ-PVJU EDUS391100A-F6

2. Dimensions

FXAQ07-12PVJU

3D07

5388

A

Uni

t: in

.

6

FXAQ-PVJU EDUS391100A-F6

FXAQ18PVJU

3D07

5389

A

Uni

t: in

.

7

FXAQ-PVJU EDUS391100A-F6

FXAQ24PVJU

3D07

5390

B

8

FXAQ-PVJU EDUS391100A-F6

3. Piping Diagrams

FXAQ07-24PVJU

Unit:in.(mm)Model Gas Liquid

FXAQ07PVJUFXAQ09PVJUFXAQ12PVJUFXAQ18PVJU

f 1/2(f 12.7)

f 1/4(f 6.4)

FXAQ24PVJU f 5/8(f 15.9)

f 3/8(f 9.5)

C: 4D034245R

9

FXAQ-PVJU EDUS391100A-F6

4. Wiring Diagrams

FXAQ07-24PVJU

C: 3

D07

5354

F

(NO

TES)

1.

: TE

RM

INAL

,

:

FIE

LD W

IRIN

G,

: C

ON

NEC

TOR

,

: C

ON

NEC

TOR

,

: P

RO

TEC

TIVE

GR

OU

ND

(SC

REW

),

: N

OIS

ELES

S G

RO

UN

D,

:

SHO

RT

CIR

CU

IT C

ON

NEC

TOR

2. IN

CAS

E U

SIN

G C

ENTR

AL R

EMO

TE C

ON

TRO

LLER

, CO

NN

ECT

IT T

O T

HE

UN

IT IN

AC

CO

RD

ANC

E W

ITH

TH

E AT

TAC

HED

INST

ALLA

TIO

N M

ANU

AL.

3. S

YMBO

LS S

HO

W A

S FO

LLO

WS:

RED

: RED

WH

T: W

HIT

E G

RN

: GR

EEN

PN

K: P

INK

YLW

: YEL

LOW

BLK

: BLA

CK

OR

G: O

RAN

GE

BR

N: B

RO

WN

BLU

: BLU

E4.

WH

EN C

ON

NEC

TIN

G T

HE

INPU

T W

IRES

FR

OM

OU

TSID

E, F

OR

CED

OFF

OR

ON

/OFF

CO

NTR

OL

OPE

RAT

ION

CAN

BE

SELE

CTE

D B

Y R

EMO

TE C

ON

TRO

LLER

. IN

DET

AILS

, REF

ER T

O T

HE

INST

ALLA

TIO

N M

ANU

AL A

TTAC

HED

TO

TH

E U

NIT

.5.

REM

OTE

CO

NTR

OLL

ER M

OD

EL V

ARIE

S AC

CO

RD

ING

TO

TH

E C

OM

BIN

ATIO

N S

YSTE

M, C

ON

FIR

M E

NG

INEE

RIN

G D

ATA

AND

CAT

ALO

GS,

ETC

. BEF

OR

E C

ON

NEC

TIN

G.

6. C

ON

FIR

M T

HE

MET

HO

D O

F SE

TTIN

G T

HE

SELE

CTO

R S

WIT

CH

(SS1

, SS2

) OF

WIR

ELES

S R

EMO

TE C

ON

TRO

LLER

BY

INST

ALLA

TIO

N M

ANU

AL A

ND

EN

GIN

EER

ING

DAT

A, E

TC.

7. X

15A,

X24

A, X

35A

AND

X38

A AR

E C

ON

NEC

TED

WH

EN T

HE

OPT

ION

AL A

CC

ESSO

RIE

S AR

E BE

ING

USE

D.

8. C

LASS

2 W

IRE

10

FXAQ-PVJU EDUS391100A-F6

FXAQ07-24PVJU

INDOORUNITA1P PRINTEDCIRCUITBOARDC5 CAPACITORF1U FUSE(T,3.15AH,250V)F2U FUSEHAP FLASHINGLAMP(SERVICEMONITORGREEN)M1F MOTOR(INDOORFAN)M1S MOTOR(SWINGFLAP)R1T THERMISTOR(AIR)R2T THERMISTOR(COILLIQUIDPIPE)R3T THERMISTOR(COILGASPIPE)V1R DIODEBRIDGEX1M TERMINALBLOCK(CONTROL)X2M TERMINALBLOCK(POWER)Y1E ELECTRONICEXPANSIONVALVEZ1C FERRITECOREZ1F NOISEFILTERPS SWITCHINGPOWERSUPPLYRECEIVER/DISPLAYUNIT(ATTACHEDTOWIRELESSREMOTECONTROLLER)A2P PRINTEDCIRCUITBOARDA3P PRINTEDCIRCUITBOARDBS1 PUSHBUTTONSWITCH(ON/OFF)H1P PILOTLAMP(ON-RED)H2P PILOTLAMP(TIMER-GREEN)H3P PILOTLAMP(FILTERSIGN-RED)H4P PILOTLAMP(DEFROST-ORANGE)SS1 SELECTORSWITCH(MAIN/SUB)SS2 SELECTORSWITCH(WIRELESSADDRESSSET)CONNECTORFOROPTIONALPARTSX15A CONNECTOR(FLOATSWITCH)X24A CONNECTOR(WIRELESSREMOTECONTROLLER)X35A CONNECTOR(GROUPCONTROLADAPTOR)X38A CONNECTOR(ADAPTORFORMULTITENANT)

C:3D075354F

11

FXAQ-PVJU EDUS391100A-F6

5. Electric Characteristics

FXAQ07-24PVJU

ModelPowersupply IFM Input(W)

Hz Volts Voltagerange MCA MOP kW FLA Cooling HeatingFXAQ07PVJU

60 208/230V Max.253VMin.187V

0.4 15 0.040 0.3 19 29FXAQ09PVJU 0.4 15 0.040 0.3 28 34FXAQ12PVJU 0.4 15 0.040 0.3 30 35FXAQ18PVJU 0.5 15 0.043 0.4 33 39FXAQ24PVJU 0.6 15 0.043 0.5 50 60

Symbol:MCA:MinimumCircuitAmpacity(A)MOP:MaximumOvercurrentProtectiveDevice(A)kW: FanMotorRatedOutput(kW)FLA: FullLoadAmpacity(A)IFM: IndoorFanMotor

Note:1.Voltagerange Unitsaresuitableforuseonelectricalsystemswherevoltagesuppliedtounitterminalsisnotbeloworabovelistedrangelimits.

2.Maximumallowablevoltageunbalancebetweenphasesis2%.3.MCA/MOP MCA=1.25×FLA MOP≤4×FLA (Nextlowerstandardfuseraring.Minimum15A)

4.SelectwiresizebasedonthevalueofMCA.5.Eitherafuseoracircuitbreakerisacceptable.

C:4D075550

12

FXAQ-PVJU EDUS391100A-F6

6. Safety Devices Setting

Model FXAQ07PVJU FXAQ09PVJU FXAQ12PVJU FXAQ18PVJU FXAQ24PVJUPCboardfuse 250V,3.15A 250V,3.15A 250V,3.15A 250V,3.15A 250V,3.15AFanmotorthermalfuse °F — — — — —Fanmotorthermalprotector °F — — — — —

C:4D047085D

13

FXAQ-PVJU EDUS391100A-F6

7. Capacity Tables7.1 Cooling Capacity at Te: 43°F (6°C)

Model

Indoorairtemp.°FWB(°CWB)(Te:43°F(6°C))61(16.1) 64(17.8) 67(19.4) 70(21.1) 72(22.2) 75(23.9)

TC SHC TC SHC TC SHC TC SHC TC SHC TC SHCMBH MBH MBH MBH MBH MBH MBH MBH MBH MBH MBH MBH

FXAQ07PVJU 5.9 5.6 6.7 6.1 7.5 6.4 8.0 6.5 8.1 6.3 8.2 6.0FXAQ09PVJU 7.5 6.5 8.5 7.2 9.5 7.3 10.1 7.4 10.2 7.4 10.4 7.0FXAQ12PVJU 9.5 7.9 10.7 8.3 12.0 8.9 12.7 8.9 12.9 8.8 13.1 8.5FXAQ18PVJU 14.2 11.7 16.1 12.7 18.0 13.7 19.1 13.6 19.3 13.3 19.7 12.4FXAQ24PVJU 18.9 15.3 21.5 16.5 24.0 18.0 25.5 17.8 25.8 17.6 26.3 16.2

TC: Totalcapacity:MBHSHC:Sensibleheatcapacity:MBH

Note:1.ThesecapacitytablescanbeusedwhenselectingaVRVindoorunit.TheactualcapacityoftheVRVsystemdependsonfactorssuchastheselectedmodelofoutdoorunits,outdoorairtemperatureandpipinglength.PleaseconfirmthatthecorrectedcapacityoftheVRVsystemsatisfiestherequiredheatload.

2. showsratedcondition.

7.2 Heating Capacity

Model

Indoorairtemp.°FDB(°CDB)(Tc:115°F(46°C))62(16.7) 65(18.3) 68(20.0) 70(21.1) 72(22.2) 75(23.9)

TC TC TC TC TC TCMBH MBH MBH MBH MBH MBH

FXAQ07PVJU 9.3 9.2 8.7 8.5 8.1 7.7FXAQ09PVJU 11.8 11.7 11.1 10.5 10.3 9.7FXAQ12PVJU 14.9 14.7 14.0 13.5 13.0 12.3FXAQ18PVJU 22.3 22.1 21.0 20.0 19.5 18.4FXAQ24PVJU 29.2 29.0 27.5 26.5 25.5 24.0

TC:Totalcapacity:MBH

Note:1.ThesecapacitytablescanbeusedwhenselectingaVRVindoorunit.TheactualcapacityoftheVRVsystemdependsonfactorssuchastheselectedmodelofoutdoorunits,outdoorairtemperatureandpipinglength.PleaseconfirmthatthecorrectedcapacityoftheVRVsystemsatisfiestherequiredheatload.

2. showsratedcondition.

7.3 Correction Factor for Cooling Capacity at Te: 48°F (9°C)

Refertothecorrectionfactortablebelowwhenamini-splitindoorunit isconnectedtoaVRVHeatPumpsystemusingaBranchPortbox.

ModelIndoorairtemp.°FWB(°CWB)(Te:48°F(9°C))

57(13.9) 61(16.1) 64(17.8) 67(19.4) 70(21.1) 72(22.2) 75(23.9)TC SHF TC SHF TC SHF TC SHF TC SHF TC SHF TC SHF

FXAQ07PVJU 0.69 1.13 0.69 1.19 0.74 1.14 0.77 1.11 0.80 1.08 0.82 1.06 0.83 1.05FXAQ09PVJU 0.69 1.12 0.69 1.19 0.74 1.15 0.77 1.11 0.80 1.07 0.82 1.06 0.83 1.05FXAQ12PVJU 0.70 1.10 0.69 1.19 0.73 1.15 0.77 1.09 0.80 1.07 0.82 1.06 0.83 1.05FXAQ18PVJU 0.69 1.12 0.69 1.18 0.75 1.13 0.78 1.09 0.82 1.06 0.83 1.05 0.85 1.05FXAQ24PVJU 0.69 1.10 0.69 1.18 0.75 1.13 0.79 1.09 0.82 1.06 0.84 1.05 0.85 1.05

TC: TotalcapacitySHF:Sensibleheatfactor

CA14A307C

14

FXAQ-PVJU EDUS391100A-F6

8. Air Velocity and Temperature Distributions (Reference Data)8.1 Cooling ModeFXAQ07PVJU <Cooling mode>

C: 3D053942

AIRFLOW DISTRIBUTIONS

TEMPERATURE DISTRIBUTIONS

15

FXAQ-PVJU EDUS391100A-F6

FXAQ09PVJU <Cooling mode>

C: 3D053943

AIRFLOW DISTRIBUTIONS

TEMPERATURE DISTRIBUTIONS

16

FXAQ-PVJU EDUS391100A-F6

FXAQ12PVJU <Cooling mode>

C: 3D052935

AIRFLOW DISTRIBUTIONS

TEMPERATURE DISTRIBUTIONS

17

FXAQ-PVJU EDUS391100A-F6

FXAQ18PVJU <Cooling mode>

C: 3D052936

AIRFLOW DISTRIBUTIONS

TEMPERATURE DISTRIBUTIONS

18

FXAQ-PVJU EDUS391100A-F6

FXAQ24PVJU <Cooling mode>

C: 3D052937

AIRFLOW DISTRIBUTIONS

TEMPERATURE DISTRIBUTIONS

19

FXAQ-PVJU EDUS391100A-F6

8.2 Heating ModeFXAQ07PVJU <Heating mode>

C: 3D053942

AIRFLOW DISTRIBUTIONS

TEMPERATURE DISTRIBUTIONS

20

FXAQ-PVJU EDUS391100A-F6

FXAQ09PVJU <Heating mode>

C: 3D053943

AIRFLOW DISTRIBUTIONS

TEMPERATURE DISTRIBUTIONS

21

FXAQ-PVJU EDUS391100A-F6

FXAQ12PVJU <Heating mode>

C: 3D052935

AIRFLOW DISTRIBUTIONS

TEMPERATURE DISTRIBUTIONS

22

FXAQ-PVJU EDUS391100A-F6

FXAQ18PVJU <Heating mode>

C: 3D052936

AIRFLOW DISTRIBUTIONS

TEMPERATURE DISTRIBUTIONS

23

FXAQ-PVJU EDUS391100A-F6

FXAQ24PVJU <Heating mode>

C: 3D052937

AIRFLOW DISTRIBUTIONS

TEMPERATURE DISTRIBUTIONS

24

FXAQ-PVJU EDUS391100A-F6

9. Sound Levels (Reference Data)

FXAQ07PVJU

4D075580

25

FXAQ-PVJU EDUS391100A-F6

FXAQ09PVJU

4D075581

26

FXAQ-PVJU EDUS391100A-F6

FXAQ12PVJU

4D075582

27

FXAQ-PVJU EDUS391100A-F6

FXAQ18PVJU

4D075583A

28

FXAQ-PVJU EDUS391100A-F6

FXAQ24PVJU

4D075584A

1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install the outdoor unit close to the sea shore, contact your local distributor.

Cautions on product corrosion

Warning Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.

Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion.

Read the user’s manual carefully before using this product. The user’s manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings.

If you have any inquiries, please contact your local importer, distributor and/or retailer.

©All rights reserved 01/21 FS

●Specifications, designs and other content appearing in this brochure are current as of January 2021 but subject to change without notice.