Upload
vuongthuan
View
214
Download
0
Embed Size (px)
Citation preview
SAVVANO™
LED Decorative Highbay
WARNINGS• This product contains chemicals known to the state of California to cause cancer,
birth defects and/or other reproductive harm.• Thoroughly wash hands after installing, handling, cleaning, or otherwise touching
this product.• Contact Hubbell Lighting, Inc. for information and direction before relamping or
replacing this light fixture.• Disconnect power before installing or servicing.• Install, operate and maintain to meet all applicable codes.• Protect all wiring connections with approved insulators (by others.)• Selected fixture voltage must match supply line voltage.
SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCEUpon receipt of this fixture, thoroughly inspect it for any damage. If any isfound, the carrier should be notified and held accountable.
INSTALLATION INSTRUCTIONSFIXTURE RECEIVING:
• For shipping purposes, the fixture will come in multiple boxes.• The upper assembly will be packaged separately from the reflector assembly and, if optioned, the lens assembly.• See instructions on pages 3 & 4 for initial fixture assembly.
Hubbell Lighting, Inc. Doc. No. 93082515A subsidiary of Hubbell Incorporated Revision A701 Millennium Drive • Greenville, SC 29607 Page 2 Phone (864) 678-1000
Industrial Lighting
®
SAV–SAVVANO DECORATIVE FIXTUREINSTALLATION INSTRUCTIONS
OPTIONALEQUIPMENT
FIGURE 1FIXURE BOXING
UPPERASSEMBLY
REFLECTORASSEMBLY
LENS RING/HARDWARE
LENS
FIXTURE RECEIVING: • For shipping purposes, the fixture will come in multiple boxes. • The upper assembly will be packaged separately from the reflector
assembly and, if optioned, the lens assembly. • See instructions on pages 3 & 4 for initial fixture assembly.
REFLECTOR INSTALLATION:
MH / MM / ML MODELS (See Figure 2B)1. Reflector can be installed on the ground or while fixture is hanging. If installing on the ground,
it is best to place fixture upside down.2. Locate the four (4) threaded studs protruding from the bottom of the glass lens ring and align them
with the holes in the reflector collar.3. Insert the studs through the holes and thread on the provided hexagonal nut. Using a 5/16”
hex driver, tighten hexagonal nut to 10 in-lbs.
4. Reflector can be installed on the ground or while fixture is hanging. If installing on the ground, it is best of place fixture upside down.
5. Locate the four (4) threaded studs protruding from the bottom of the glass lens ring and align them with the holes in the reflector collar.
6. Insert the studs through the holes and install the provided hexagonal standoffs along with lock washers. Using a 1/4” hex driver, tighten the whexagonal standoffs to 10 in-lbs.
LX/ LH MODELS (See Figure 2A)
INSTALLATION INSTRUCTIONS
REFLECTORCOLLAR ASSEMBLY
REFLECTORCOLLAR ASSEMBLY
FIGURE 2BREFLECTOR COLLAR MOUNTING
MH / MM / ML
FIGURE 2AREFLECTOR COLLAR MOUNTING
LX / LH
Hubbell Lighting, Inc. Doc. No. 93082515A subsidiary of Hubbell Incorporated Revision A701 Millennium Drive • Greenville, SC 29607 Page 3 Phone (864) 678-1000
Industrial Lighting
®
SAV-SAVVANO DECORATIVE FIXTUREINSTALLATION INSTRUCTIONS
HEXAGONALSTANDOFF4 PLACES
LOCKWASHER4 PLACES
THREADEDSTUD4 PLACES
HEXAGONALNUT4 PLACES
THREADEDSTUD4 PLACES
REFLECTOR INSTALLATION: MH / MM / ML MODELS (See Figure 2B) 1. Reflector can be installed on the ground or while fixture is hanging. If
installing on the ground, it is best to place fixture upside down. 2. Locate the four (4) threaded studs protruding from the bottom of the
glass lens ring and align them with the holes in the reflector collar. 3. Insert the studs through the holes and thread on the provided hexagonal
nut. Using a 5/16" hex driver, tighten hexagonal nut to 10 in-lbs. LX/ LH MODELS (See Figure 2A) 4. Reflector can be installed on the ground or while fixture is hanging. If
installing on the ground, it is best of place fixture upside down. 5. Locate the four (4) threaded studs protruding from the bottom of the
glass lens ring and align them with the holes in the reflector collar. 6. Insert the studs through the holes and install the provided hexagonal
standoffs along with lock washers. Using a 1/4" hex driver, tighten the hexagonal standoffs to 10 in-lbs.
LENS INSTALLATION (If Optioned):
1. Once the reflector has been mounted to the upper assembly, then the lens can be installed.2. Seat the lens into the bottom of the reflector.3. Orient Lens Mounting Ring such that short leg of the cross section is on top and install over the lip of the reflector
and lens. See Figure 3B.4. While manually holding the ring together, install screw through bracket holes and thread on hexagonal nut and
tighten till snug.
INSTALLATION INSTRUCTIONS
Hubbell Lighting, Inc. Doc. No. 93082515A subsidiary of Hubbell Incorporated Revision A701 Millennium Drive • Greenville, SC 29607 Page 4 Phone (864) 678-1000
Industrial Lighting
®
SAV-SAVVANO DECORATIVE FIXTUREINSTALLATION INSTRUCTIONS
LENS(OPTIONAL)
REFLECTOR
LENS MOUNTING RING
(OPTIONAL)
HEXAGONALNUT
SCREW
LENS MOUNTING RINGSEE NOTE 3
LENS
REFLECTOR
FIGURE 3ALENS MOUNTING
FIGURE 3B
LENS INSTALLATION (If Optioned): 1. Once the reflector has been mounted to the upper assembly,
then the lens can be installed. 2. Seat the lens into the bottom of the reflector 3. Orient Lens Mounting Ring such that short leg of the cross
section is on top and install over the lip of the reflector and lens. See Figure 3B.
4. While manually holding the ring together, install screw through bracket holes and thread on hexagonal nut and tighten till snug.
GENERAL INFORMATION
• All 12” (304.8 mm) minimum supply wire outside of conduit.• Fixture mounting hub conduit threads are 3/4-14 NPS.
PENDANT MOUNTING: (See Figures 4A & 4B)
1. Remove the Wire Access Cover and Mounting Hub Assembly from the fixture top by removing the (3) ¼” screws using a 3/8” Hex driver or flathead screwdriver. See Figure 4B.
2. The Mounting Hub Assembly should be installed on the already-hanging pendant conduit. See Figure 4A. The conduit and conduit lock nut should be securely fastened into the Mounting Hub at this time.
3. Thread the Set Screw into the Mounting Hub to lock into the Conduit using a 1/8” Allenhead driver. See Figure 4A.4. Loosely thread the Hub Lock Nut onto the Mounting Hub so that there is play between the Hub Plate and Mounting Hub.
See Figure 4A.5. Feed electrical supply wire through the conduit and out the bottom of the Mounting Hub, with 12” of extra wire
protruding from the bottom.6. Hang fixture so that the Mounting Hub sets into the Top Plate and the hub flanges engage the inside of the top plate.
Align holes in the Hub Plate with the holes in the Top Plate and insert and tighten the (2) ¼” screws to secure the position of the Hub. Tighten the Hub Lock Nut to the lock the plate and hub in place.
INSTALLATION INSTRUCTIONS
7. Pull the excess fixture and incoming wiring out through the Wire Access Cover hole and make the wiring connections. See appropriate WIRING SCHEMATIC for reference. Incoming power to be connected to the white and black wires. Ensure incoming wiring ground wire connected to fixture ground connector. See warnings above about wire connections. Dress wires as needed.
8. Once all wiring connections are made, place all wiring back inside wire box under the Access Cover and replace cover with (1) ¼” screw.
FIGURE 4APENDANT-MOUNTING HUB
ASSEMBLY
HUB LOCK NUT
HUB PLATE
MOUNTINGHUB
NOTE: SET SCREW TO BE THREADED BELOW OUTER
THREADS OF HUB FOR LOCKNUT TO BE ABLE TO THREAD
SCREW2x 1/4-20X.50
SCREW1/4-20X.50
MOUNTING HUBASSEMBLY
3/8" BUSHING
WIRE ACCESS COVER
Hubbell Lighting, Inc. Doc. No. 93082515A subsidiary of Hubbell Incorporated Revision A701 Millennium Drive • Greenville, SC 29607 Page 5 Phone (864) 678-1000
Industrial Lighting
®
SAV-SAVVANO DECORATIVE FIXTUREINSTALLATION INSTRUCTIONS
CONDUIT FORPENDENT HANGING
CONDUITLOCK NUT
FIGURE 4BPENDENT MOUNT
ASSEMBLY
FIXTURETOP PLATE
GENERAL INFORMATION • All 12” (304.8 mm) minimum supply wire outside of conduit. • Fixture mounting hub conduit threads are 3/4-14 NPS.
PENDANT MOUNTING: (See Figures 4A & 4B) 1. Remove the Wire Access Cover and Mounting Hub Assembly from
the fixture top by removing the (3) 1/4" screws using a 3/8" Hex driver or flathead screwdriver. See Figure 4B.
2. The Mounting Hub Assembly should be installed on the already-hanging pendant conduit. See Figure 4A. The conduit and conduit lock nut should be securely fastened into the Mounting Hub at this time.
3. Thread the Set Screw into the Mounting Hub to lock into the Conduit using a 1/8" Allenhead driver. See Figure 4A.
4. Loosely thread the Hub Lock Nut onto the Mounting Hub so that there is play between the Hub Plate and Mounting Hub. See Figure 4A
5. Feed electrical supply wire through the conduit and out the bottom of the Mounting Hub, with 12" of extra wire protruding from the bottom.
6. Hang fixture so that the Mounting Hub sets into the Top Plate and the hub flanges engage the inside of the top plate. Align holes in the Hub Plate with the holes in the Top Plate and insert and tighten the (2) 1/4" screws to secure the position of the Hub. Tighten the Hub Lock Nut to the lock the plate and hub in place.
7. Pull the excess fixture and incoming wiring out through the Wire Access Cover hole and make the wiring connections. See appropriate WIRING SCHEMATIC for reference. Incoming power to be connected to the white and black wires. Ensure incoming wiring ground wire connected to fixture ground connector. See warnings above about wire connections. Dress wires as needed.
8. Once all wiring connections are made, place all wiring back inside wire box under the Access Cover and replace cover with (1) 1/4" screw.
GENERAL INFORMATION
• All 12” (304.8 mm) minimum supply wire outside of conduit.• Fixture mounting hub conduit threads are 3/4-14 NPS.
PENDANT MOUNTING: (See Figures 4A & 4B)
1. Insert end of Cord (B) through Hook (A). Supply Cord is to be rated for a minimum of 90 degC 16/3 SOW-A.2. Remove Wire Access Cover after removing ¼” retaining screw.3. Loosen Hub Locknut and remove Hub and Hub Plate by removing (2) ¼” Screws.4. Insert rubber Bushing (E) between Washers (G) and place inside Mounting Hub. Place Cord Grip (C) with cone shape up
on top of washer (G).5. Thread Hook Lock Nut (D) to within 1/8” of the top of the hook threads.6. Insert Cord (B) through cord grip and washers and through the mounting hub.7. Thread the Hook into the ¾” NPS hole in the Mounting Hub down to the lock nut. Use pliers and wrench to tighten the
Hook Lock Nut (D) to lock the hook in place. CAUTION: Do not twist the Hook by using a screwdriver blade - too much force could break the Hook.
8. Using a 1/8” Allen head driver, tighten Set Screw in Mounting Hub to secure Hook from loosening.9. Place Hub into Top Plate of Housing so that the Hub flanges engage inside of the plate. Align holes in Hub Plate with
holes in Top Plate and insert and tighten ¼” screws to secure position of Hub. Tighten the Hub Locknut to lock Plate and Hub in place.
10. Pull the excess fixture and incoming wiring out through the Wire Access Cover hole and make the wiring connections. See appropriate WIRING SCHEMATIC for reference. Incoming power to be connected to the white and black wires. Ensure incoming wiring ground wire connected to fixture ground connector. See warnings above about wire connections. Dress wires as needed.
11. Once all wiring connections are made, place all wiring back inside wire box under the Access Cover and replace cover with (1) ¼” screw.
12. Attach Hook Closure Bracket onto end of Hook with screw provided. After fixture is hung, the Closure Bracket should be secured across the Hook opening to prevent disengagement.
INSTALLATION INSTRUCTIONS
Hubbell Lighting, Inc. Doc. No. 93082515A subsidiary of Hubbell Incorporated Revision A701 Millennium Drive • Greenville, SC 29607 Page 6 Phone (864) 678-1000
Industrial Lighting
®
SAV-SAVVANO DECORATIVE FIXTUREINSTALLATION INSTRUCTIONS
FIGURE 5AHOOK LOOP ASSEMBLY
FIGURE 5CHOOK LOOP ASSEMBLY
SCREW1/4-20X.50
WIRE ACCESS COVER
3/8" BUSHING
SCREW2x 1/4-20X.50
FIXTURETOP PLATE
HUB LOCK NUT
NOTE: SET SCREW TO BE THREADED BELOW OUTERTHREADS OF HUB FOR LOCKNUT TO BE ABLE TO THREAD
MOUNTINGHUB
HUB PLATE
A
D
HOOKCLOSUREBRACKET/SCREW
G
E
G
C
FIGURE 5BMOUNTING HUB
ASSEMBLY
B
GENERAL INFORMATION: • All 12” (304.8 mm) minimum supply wire outside of conduit. • Fixture mounting hub conduit threads are 3/4-14 NPS.
HOOK/LOOP MOUNTING: (See Figures 5A, 5B & 5C) 1. Insert end of Cord (B) through Hook (A). Supply Cord is to be rated for a minimum
of 90 degC 16/3 SOW-A. 2. Remove Wire Access Cover after removing 1/4" retaining screw 3. Loosen Hub Locknut and remove Hub and Hub Plate by removing (2) 1/4" Screws. 4. Insert rubber Bushing (E) between Washers (G) and place inside Mounting Hub.
Place Cord Grip (C) with cone shape up on top of washer (G). 5. Thread Hook Lock Nut (D) to within 1/8" of the top of the hook threads. 6. Insert Cord (B) through cord grip and washers and through the mounting hub. 7. Thread the Hook into the ¾” NPS hole in the Mounting Hub down to the lock nut.
Use pliers and wrench to tighten the Hook Lock Nut (D) to lock the hook in place. CAUTION: Do not twist the Hook by using a screwdriver blade - too much force could break the Hook.
8. Using a 1/8” Allenhead driver, tighten Set Screw in Mounting Hub to secure Hook from loosening.
9. Place Hub into Top Plate of Housing so that the Hub flanges engage inside of the plate. Align holes in Hub Plate with holes in Top Plate and insert and tighten 1/4" screws to secure position of Hub.Tighten the Hub Locknut to lock Plate and Hub in place.
10. Pull the excess fixture and incoming wiring out through the Wire Access Cover hole and make the wiring connections. See appropriate WIRING SCHEMATIC for reference. Incoming power to be connected to the white and black wires. Ensure incoming wiring ground wire connected to fixture ground connector. See warnings above about wire connections. Dress wires as needed.
11. Once all wiring connections are made, place all wiring back inside wire box under the Access Cover and replace cover with (1) 1/4" screw.
12. Attach Hook Closure Bracket onto end of Hook with screw provided. After fixture is hung, the Closure Bracket should be secured across the Hook opening to prevent disengagement.
Hubbell Lighting, Inc. Doc. No. 93082515A subsidiary of Hubbell Incorporated Revision A701 Millennium Drive • Greenville, SC 29607 Page 6 Phone (864) 678-1000
Industrial Lighting
®
SAV-SAVVANO DECORATIVE FIXTUREINSTALLATION INSTRUCTIONS
FIGURE 5AHOOK LOOP ASSEMBLY
FIGURE 5CHOOK LOOP ASSEMBLY
SCREW1/4-20X.50
WIRE ACCESS COVER
3/8" BUSHING
SCREW2x 1/4-20X.50
FIXTURETOP PLATE
HUB LOCK NUT
NOTE: SET SCREW TO BE THREADED BELOW OUTERTHREADS OF HUB FOR LOCKNUT TO BE ABLE TO THREAD
MOUNTINGHUB
HUB PLATE
A
D
HOOKCLOSUREBRACKET/SCREW
G
E
G
C
FIGURE 5BMOUNTING HUB
ASSEMBLY
B
GENERAL INFORMATION: • All 12” (304.8 mm) minimum supply wire outside of conduit. • Fixture mounting hub conduit threads are 3/4-14 NPS.
HOOK/LOOP MOUNTING: (See Figures 5A, 5B & 5C) 1. Insert end of Cord (B) through Hook (A). Supply Cord is to be rated for a minimum
of 90 degC 16/3 SOW-A. 2. Remove Wire Access Cover after removing 1/4" retaining screw 3. Loosen Hub Locknut and remove Hub and Hub Plate by removing (2) 1/4" Screws. 4. Insert rubber Bushing (E) between Washers (G) and place inside Mounting Hub.
Place Cord Grip (C) with cone shape up on top of washer (G). 5. Thread Hook Lock Nut (D) to within 1/8" of the top of the hook threads. 6. Insert Cord (B) through cord grip and washers and through the mounting hub. 7. Thread the Hook into the ¾” NPS hole in the Mounting Hub down to the lock nut.
Use pliers and wrench to tighten the Hook Lock Nut (D) to lock the hook in place. CAUTION: Do not twist the Hook by using a screwdriver blade - too much force could break the Hook.
8. Using a 1/8” Allenhead driver, tighten Set Screw in Mounting Hub to secure Hook from loosening.
9. Place Hub into Top Plate of Housing so that the Hub flanges engage inside of the plate. Align holes in Hub Plate with holes in Top Plate and insert and tighten 1/4" screws to secure position of Hub.Tighten the Hub Locknut to lock Plate and Hub in place.
10. Pull the excess fixture and incoming wiring out through the Wire Access Cover hole and make the wiring connections. See appropriate WIRING SCHEMATIC for reference. Incoming power to be connected to the white and black wires. Ensure incoming wiring ground wire connected to fixture ground connector. See warnings above about wire connections. Dress wires as needed.
11. Once all wiring connections are made, place all wiring back inside wire box under the Access Cover and replace cover with (1) 1/4" screw.
12. Attach Hook Closure Bracket onto end of Hook with screw provided. After fixture is hung, the Closure Bracket should be secured across the Hook opening to prevent disengagement.
INSTALLATION INSTRUCTIONS
WIRE GUARD INSTALLATION (If Optioned):
1. With the screws removed, spread the guard apart slightly and fit it around the lens ring already attached to the reflector.2. The guard should mount around the lens ring such that the ring fits between the top two circular rings.3. Insert the screws (2x) through the mounting holes and thread on the hexagonal kepis nuts (2x). Tighten the nuts till the
guard is clamped around the lens ring.
Hubbell Lighting, Inc. Doc. No. 93082515A subsidiary of Hubbell Incorporated Revision A701 Millennium Drive • Greenville, SC 29607 Page 9 Phone (864) 678-1000
Industrial Lighting
®
SAV-SAVVANO DECORATIVE FIXTUREINSTALLATION INSTRUCTIONS
33.5 26.5
MH / MM / ML MODELS
LX / LH MODELS
WIRE GUARD INSTALLATION (If Optioned): 1. With the screws removed, spread the guard apart slightly and fit it around the lens ring already attached to the reflector. 2. The guard should mount around the lens ring such that the ring fits between the top two circular rings. 3. Insert the screws (2x) through the mounting holes and thread on the hexagonal kepis nuts (2x). Tighten the nuts till the
guard is clamped around the lens ring.
WIRE GUARD
SCREW (2X)
KEPIS NUT (2X)FIGURE 6A
WIRE GUARD ASSEMBLY
INSTALLATION INSTRUCTIONS
OCCUPANCY SENSOR INSTALLATION (If Optioned):
NOTE: If a wire guard is supplied, the wire guard needs to be installed first (see Page 9, Fig. 7A) before installing sensor on thebracket. Position the guard so the sensor bracket fits through the top two rings of the guard.
1. Position the sensor box (without the tightening ring attached) on top of the bracket and place the threaded shaft through the hole in the bracket. Fasten the tightening ring onto the threads until sensor box is secure. See Fig. 7B.
2. Screw the sensor lens onto the threaded shaft until secure. See Fig. 7C.
Hubbell Lighting, Inc. Doc. No. 93082515A subsidiary of Hubbell Incorporated Revision A701 Millennium Drive • Greenville, SC 29607 Page 10 Phone (864) 678-1000
Industrial Lighting
®
SAV-SAVVANO DECORATIVE FIXTUREINSTALLATION INSTRUCTIONS
Mounting Bracket
FIGURE 7BSENSOR INSTALLATION
FIGURE 7CSENSOR INSTALLATION
Mounting Bracket
OCCUPANCY SENSOR INSTALLATION (If Optioned): NOTE: If a wireguard is supplied, the wire guard needs to be installed first (see Page 9, Fig. 7A) before installing sensor on the bracket. Position the guard so the sensor bracket fits through the top two rings of the guard. 1. Position the sensor box (without the tightening ring attached) on top of the bracket and place the threaded shaft through
the hole in the bracket. Fasten the tightening ring onto the threads until sensor box is secure. See Fig. 7B 2. Screw the sensor lens onto the threaded shaft until secure. See Fig. 7C.
WIRE GUARD ASSEMBLYW/ OCCUPANCY SENSOR
FIGURE 7AWIRE GUARD ASSEMBLYW/ OCCUPANCY SENSOR
LINE DRAWINGS
Drop (DLR) Lens Conical Drop (CDL) Lens P95/Clear (CLR)/No Lens
Drop (DLR) Lens Conical Drop (CDL) Lens
P95/Clear (CLR)/No Lens
31.0”
22.6”
28.4”30.1”
10.2”
25.0”
16.5”
23.1”
10.2”
21.8”
31.0”
22.6”
28.4”30.1”
10.2”
25.0”
16.5”
23.1”
10.2”
21.8”
22” Option
16” Option
WIRING DIAGRAMS
HIL_0355_SAV_IN_17 7/17
Hubb
ell L
ight
ing,
Inc.
Do
c. N
o. 9
3082
515
A su
bsid
iary
of H
ubbe
ll In
corp
orat
ed
R
evis
ion
A70
1 M
illen
nium
Driv
e • G
reen
ville
, SC
296
07
Pag
e 11
Pho
ne (8
64) 6
78-1
000
Indu
stria
l Lig
htin
g®
SAV-
SAVV
ANO
DEC
ORA
TIVE
FIX
TURE
INST
ALLA
TIO
N IN
STRU
CTIO
NS
ELEC
TRIC
AL D
IAG
RAM
LX /
LH M
OD
ELS
BLUE
BLACK
WHITE
BLACK
WHITELEADS
BLACKLEADS
BROWN
BLUE
BLUE
BROWN
OPTION - FUSING
BLACK
WHITE
TERMINAL ATTACHED TOWIRE BOX (INSIDE)
GREEN
GREEN
BLACK
RED
BLUE
WHITE
BLACK
RED
-W/O OCC. SENSOR: VIOLET AND GRAY LEADS TO BE ROUTED UPTHROUGHWIRE BOX WITH BLACK, WHITE, & GREEN LEADS EXITING FIXTURE
-W/ OCC. SENSOR: VIOLET AND GRAY LEADS TO BE ATTACHED TOAPPROPRIATE CONNECTORS ON SENSOR POWERPACK.
DIMMING OPTION
VIOLET LEADS GRAY LEADS
FROM DRIVER #2FROM DRIVER #1
FROM DRIVER #2FROM DRIVER #1
SEE TERMINATION OPTIONS
DRIVER #2
DRIVER #1
SURGESUPPRESSOR
BLACKLEADS
WHITELEADS
RED
RED
GREEN
GREEN
OPTION -OCCUPANCY SENSOR
POWERPACK
OPTION -OCCUPANCY SENSOR
Hubbell Lighting, Inc. Doc. No. 93082515A subsidiary of Hubbell Incorporated Revision A701 Millennium Drive • Greenville, SC 29607 Page 9 Phone (864) 678-1000
Industrial Lighting
®
SAV-SAVVANO DECORATIVE FIXTUREINSTALLATION INSTRUCTIONS
BLUE
BLACK
WH
ITE
BLACKWH
ITELEAD
SBLAC
KLEAD
S
BROWN
BLUE
BLUE
BRO
WN
OPTIO
N - FUSING
BLACK
WH
ITE
TERM
INAL ATTAC
HED
TOW
IRE BO
X (INSID
E)
GR
EEN
GR
EEN
BLACK
RED
BLUE
WH
ITE
BLACK
RED
VIOLET AN
D G
RAY LEAD
TO BE
GR
OU
PED W
ITH BLAC
K, WH
ITE, &G
REEN
LEADS EXITIN
G FIXTU
RE
WH
EN D
IMM
ING
OPTIO
N IS U
TILIZED
DIMM
INGO
PTION
VIOLET LEAD
SG
RAY LEAD
S
FRO
M D
RIVER
#2FR
OM
DR
IVER #1
FRO
M D
RIVER
#2FR
OM
DR
IVER #1
SEE TERM
INATIO
N O
PTION
S
DRIVER #2
DRIVER #1
SUR
GE
SUPPR
ESSOR
BLACK
LEADS
WH
ITELEAD
S
RED
RED
GR
EEN
GREEN
ELECTRICAL DIAGRAMLX / LH MODELS
Hubb
ell L
ight
ing,
Inc.
Do
c. N
o. 9
3082
515
A su
bsid
iary
of H
ubbe
ll In
corp
orat
ed
R
evis
ion
A70
1 M
illen
nium
Driv
e • G
reen
ville
, SC
296
07
Pag
e 12
Pho
ne (8
64) 6
78-1
000
Indu
stria
l Lig
htin
g®
SAV-
SAVV
ANO
DEC
ORA
TIVE
FIX
TURE
INST
ALLA
TIO
N IN
STRU
CTIO
NS
ELEC
TRIC
AL D
IAG
RAM
MH
/ MM
/ M
L M
OD
ELS
BLACK
BLACK
WHITE
BLACK
WHITELEADS
BLACKLEADS
BLUE
BROWN
OPTION - FUSING
BLACK
WHITE
TERMINAL ATTACHED TOWIRE BOX (INSIDE)
GREEN
GREEN
RED
BLUE
WHITE
BLACK
RED
DIMMING OPTION
VIOLET LEADS GRAY LEADS
FROM DRIVER #1
FROM DRIVER #1
DRIVER #1
SURGESUPPRESSOR
BLACKLEADS
WHITELEADS
SEE TERMINATION OPTIONS
RED
GREEN
OPTION -OCCUPANCY SENSOR
POWERPACK
-W/O OCC. SENSOR: VIOLET AND GRAY LEADS TO BE ROUTED UPTHROUGHWIRE BOX WITH BLACK, WHITE, & GREEN LEADS EXITING FIXTURE
-W/ OCC. SENSOR: VIOLET AND GRAY LEADS TO BE ATTACHED TOAPPROPRIATE CONNECTORS ON SENSOR POWERPACK.
Hubbell Lighting, Inc. Doc. No. 93082515A subsidiary of Hubbell Incorporated Revision A701 Millennium Drive • Greenville, SC 29607 Page 10 Phone (864) 678-1000
Industrial Lighting
®
SAV-SAVVANO DECORATIVE FIXTUREINSTALLATION INSTRUCTIONS
BLACK
BLACK
WH
ITE
BLACKWH
ITELEAD
SBLAC
KLEAD
S
BLUE
BRO
WN
OPTIO
N - FUSING
BLACK
WH
ITE
TERM
INAL ATTAC
HED
TOW
IRE BO
X (INSID
E)
GR
EEN
GR
EEN
RED
BLUE
WH
ITE
BLACK
RED
VIOLET AN
D G
RAY LEAD
TO BE
GR
OU
PED W
ITH BLAC
K, WH
ITE, &G
REEN
LEADS EXITIN
G FIXTU
RE
WH
EN D
IMM
ING
OPTIO
N IS U
TILIZED
DIMM
INGO
PTION
VIOLET LEAD
SG
RAY LEAD
S
FRO
M D
RIVER
#1
FRO
M D
RIVER
#1
DRIVER #1
SUR
GE
SUPPR
ESSOR
BLACK
LEADS
WH
ITELEAD
S
SEE TERM
INATIO
N O
PTION
S
RED
GR
EEN
ELECTRICAL DIAGRAMMH / MM / ML MODELS