12
Determine product quality with ROTRONIC Aw products ROTRONIC Aw devices for laboratory and portable systems Special USB probes for direct PC connection Aw Quick function provides accurate Aw readings within a few minutes Laboratory bench-top indicator reads up to 4 probes simultaneously Large choice of probes for different applications Easy to calibrate and maintain FAST AND PRECISE WATER ACTIVITY MEASUREMENTS. INTRODUCING AIRCHIP DIGITAL TECHNOLOGY. WATER ACTIVITY MEASUREMENT WATER ACTIVITY

WATER ACTIVITY - Pryde Measurement Pty Ltdpryde.com.au/.../Water_Activity_Catalogue.pdf · water activity measurements with up to four probes. Connect station probes and insertion

  • Upload
    others

  • View
    11

  • Download
    0

Embed Size (px)

Citation preview

  • • DetermineproductqualitywithROTRONICAwproducts

    • ROTRONICAwdevicesforlaboratoryandportablesystems

    • SpecialUSBprobesfordirectPCconnection

    • AwQuickfunctionprovidesaccurateAwreadings

    withinafewminutes

    • Laboratorybench-topindicatorreadsupto4probes

    simultaneously

    • Largechoiceofprobesfordifferentapplications

    • Easytocalibrateandmaintain

    FAST AND PRECISE WATER ACTIVITY MEASUREMENTS.INTRODUCING AIRCHIP DIGITAL TECHNOLOGY.

    WATER ACTIVITY MEASUREMENT

    WATER ACTIVITY

  • ROTRONIC offers a complete range of water activity products. Use any combination of probes to fit your application.

    ROTRONIC products are freely combinable and can be perfectly adapted to your needs. The devices are accurate and

    are characterized by their high efficiency, exchangeability, and ease of calibration.

    BE PRECISE:ADVANTAGES AT A GLANCE.

    What is water activity?Wateractivity,bydefinition,isthemeasurementofwater

    vaporpressuregeneratedby the freeornon-chemically

    bound water in foods and other products. The bound

    waterandmoisturecontentcannotbemeasureddirectly

    withthismethod.TheAwvalue(range:0.00...1.00aw)is

    animportantindicatorfortheshelflifeoffoods,pharma-

    ceuticalandcosmeticproductsanditstronglyinfluences

    theoccurrenceandgrowthofmicroorganisms.

    Water activity Contaminantaw=0.91…0.95 Manybacteriaaw=0.88 Manyyeastsaw=0.80 Manymildewsaw=0.75 Halophilebacteriaaw=0.70 Osmiophileyeastsaw=0.65 Xerophilemildew

    WATER ACTIVITY

    Why measure water activity?Thefreewaterinaproductinfluencesitsmicrobiological,chemicalandenzymaticstability.Thisisofgreatimportanceespeciallyforper-

    ishableproductssuchasfoods,grains,seedsandparticularlyforpharmaceuticalpowdersandtablets.Ifthereistoomuchfreewater,the

    foodisspoiled.Toolittlewatercanadverselyaffectproductproperties.

    Thetableshowstypicalgrowththresholdsbelowwhichthespecifiedorganismcannot

    reproduceandthereforespoiltheproduct.Thereforewateractivityhasasignificantim-

    pactontheshelflifeofaproduct.

    Themeasurementofwateractivityalsoprovidesusefulinformationaboutcharacteristics

    suchascohesion,storability,agglomerationorflowpropertiesofpowdersandtabletsor

    theadhesionofcoatings.

    Aw Quick functionality for very fast and precise resultsRegularAwmeasurementtakesaboutanhourtodetermineexactAwvalue.TheROTRONICAwQuickfunctionallowsAwmeasurement

    resultsin5minutesorless.Thefunctionisnearlyaspreciseastheregularmeasurementmethod.Itrequiresanenvironmentwithstable

    temperaturesvariationswhichismostlygiveninlaboratoryandindoorapplications.Thebench-topunitHygroLabC1,thehandhelddevice

    HP23-AW-AandthesoftwareHW4-P-QUICK-VxallincludetheAwQuickcapability.

    Foradditionaltimesavingupto4probescanbeconnectedtotheHygroLabC1.Forapplicationswithalargeamountofmeasurementsup

    to64USBprobescanbedirectlyconnectedtotheHW4softwarewhichalsoprovidestheAwQuickfunction.

    AllmeasurementresultsaresavedinlogfileseitherdirectlyinthedeviceorviatheHW4softwareonthePC.

    Software calibrationIt'sessentialthatinstrumentshaveregularcalibrationcheckstraceabletonationalstand-

    ardsensuringoptimumperformanceatalltimes.HW4softwareprovidesconvenient,easy

    tousecontrolofthecalibrationprocess,andifrequired,thesensoradjustmentsequence:

    • Fullsoftwarecontrolofcalibrationoradjustmentsequenceandtiming

    • Singleormultiplepointsadjustment/calibration

    • Preciseadjustmentto0.001Aw(0.1%RH)and0.1K

    • Automaticgenerationofadjustment,calibrationandconfigurationreports

    • Pre-configuredtosuitROTRONICSCScertifiedhumiditystandards

    • Userconfigurablecalibrationandadjustmentprocess

  • WATER ACTIVITY

    What is equilibrium relative humidity?Equilibriumrelativehumidity(ERH)isthevalueofrelativehumidityintowhichahygroscopicproductcanbeplacedwherenonetexchangeof

    moisturebetweentheproductandthesurroundingenvironmentcantakeplace.Itisexpressedonascaleof0…100%.ERHistypicallyusedinthe

    paperandpharmaceuticalindustries,butcanbeappliedtoalmostanyproductthatissensitivetomoisture,orwherethepresenceofmoisture

    canaffectproducthandling.

    Aw or ERH?BothAwandERHareanexpressionoftheamountoffreewatervaporpresentonaproduct,bothatitssurfaceandwithinitsstructure,andare

    practicallythesamemeasurementexpressedinaslightlydifferentway.Throughoutthisbrochurewewillrefertowateractivity,butthiscanbe

    interchangedwithERH.Wherespecified,ROTRONICproductsoffertheusertheoptiontoselectdisplayunitsasAwor%RH.

    What is water content?Watercontent,whenreferring toasolidmaterial, isanexpressionof thepercentageof thematerialsweightwhich iswater (both in liquidor

    gaseousphase);usuallyreferredtoas‘percentmoisturecontent’.Thistermiswidelyusedinmanyareasofindustry.

    Water activity or water content?There is frequently confusion between water activity and water content

    measurements. In many industries, water content is used to control the

    amountofwaterpresentinaproductforquantitativereasons.Forexample,

    ifaproduct issoldbyweight,controlling itswatercontentmaybeuseful

    in maintaining product quality, but can also impact on profitability (more

    waterequalsmoreprofit).Wateractivity ismoresignificant forqualitative

    considerations such as product stability, shelf life (e.g. microbiological &

    enzymaticstability,aroma retention),handlingcharacteristics (e.g.agglo-

    meration of powders), physical properties (e.g. dimensions of paper) and

    chemicalstability(e.g.pharmaceuticals).Wateractivityandwatercontent

    canberelatedbyagraphcalledaSorptionIsotherm(seediagram)soifthe

    user has the ability to measure both parameters, the relationship can be

    definedandeachparameterderivedfromtheother(interpolation).Inpractice,thesorptionisothermmaybeimpracticaltouse,because,notonly

    doestherelationshipbetweenAwandmoisturecontentchangewithtemperatureofmeasurement,butalsoanyvariationsinthematerialcompo-

    sitionhasamodifyingeffect.Thisisespeciallythecasewithproductsofnaturaloriginsuchasfoodandpaper.Theusershouldthereforedecide

    whichparameterofmeasurementisbestsuitedtotheirproductsandprocesses.Forqualitycontrolpurposesmoisturecontentlimitsareeasily

    convertedtowateractivitylimitsbyverysimplecomparativetests.Wateractivitymeasurementoffersanon-destructive,easy-to-usemeasurement

    inawiderangeofconvenientconfigurationsforbothlaboratoryandon-siteuse.

  • WATER ACTIVITY

    Order code HygroLab C1

    Probeconnections 4xHC2stationprobeorHC2insertionprobe

    Parametersshown Aw,%RH,°C,°F

    AwQuickfunction IntegratedandviaHW4softwareHW4-P-QUICK-Vx(inshipmentincluded)

    Calculations Allpsychrometriccalculationsavailableoruserdefinedcalculations

    Probeadjustment Singleormultiplepointforrelativehumidity&temperature

    Oneortwopointtemperature

    Memory 4x500Awvalues(2,000Awvalues)

    Measurementinterval 1s

    Start-uptime 3s

    Powersupply 8…16VDCwithACadapter

    Interfaces EthernetandUSB

    HW4compatible V3.1andhigher

    Rangeofapplication -10…60°C(14…140°F)/0…1Aw/0…100%RH

    LCD 3-linealphanumericwithtrendindicators

    Clock Realtimeclockprovidesatimestampforeverymeasurement

    Currentconsumption Max.120mA(12VDC,backlightON,4probesconnected,Ethernet)

    IPprotectionclass IP21

    CE/EMCconform EMC2008/108/EG

    FDA/GAMP FDA21CFRpart11/GAMP5

    Dimensions/Weight 225x170x70mm/1100g

    Material Aluminum,ABS-757

    HygroLab C1

    Laboratory applicationROTRONICprovidesahigh-endlaboratorydevice–theHygroLabC1–for

    wateractivitymeasurementswithuptofourprobes.Connectstation

    probesandinsertionprobesformeasuringwateractivityincheese,meat,

    tobacco,buildingmaterials,animalfeed,pharmaceuticalsproductsand

    muchmore.

    Validated softwareEasy-to-useandintuitive,thelaboratorygradeindicatorcanbeusedby

    anyone.HW4runningonaPCprovidesremotemonitoringwithcharting

    anddatarecordingfunctions.

    Features• 4inputchannelsforHC2stationprobesorHC2insertionprobes

    canbeconnectedformeasurementofwateractivity,relativehumidity

    andtemperature

    • AwQuickfunctionforfastmeasurementresults(typically4-5minutes)

    • Audiblealarmtoindicatecompletedmeasurement

    • Savesupto2,000datarecordswith%RH,°C/°F,dateandtime

  • PS-40

    HC2-AW

    WP-40

    AW-KHS

    WATER ACTIVITY

    Order code HC2-AW

    Probetype MeasurementprobewithUARTinterface

    Connection ViaUART,1mcable

    Forusewith HygroLabC1,HP23-AW-A

    Accuracyat23°C±5K(73.4°F) ±0.008Aw/±0.8%RH/±0.1K

    Temperaturedependence 0.001K/K,0.0002aw/K

    Sensor HYGROMER®WA-1/Pt-100,1/3DINClassB

    Calculations Deworfrostpoint

    Longtermstability

  • WATER ACTIVITY

    Order code HP23-AW-A

    Probeconnections 2HygroClip2oranaloginput0…3.2VDC(powersupplyforanalogprobe:5VDC)

    Parametersshown Aw,%RH,°C,°F

    AwQuickfunction IntegratedorviaoptionalHW4softwareHW4-P-QUICK-Vx

    Calculations Allpsychrometriccalculationsavailable

    Probeadjustment Singleormultiplepointforrelativehumidity&temperatureoneortwopointtemperature

    Memory Capturemode:8x250values

    Loggingmode:10,000values

    Measurementinterval 1s,10s,1min,10min

    Start-uptime 3s

    Powersupply 9VbatteryorUSB/mainsadapterviaminiUSB

    Interfaces MiniUSB

    HW4compatible Yes,forallHW4versions

    Rangeofapplication -10…60°C(14…140°F)/0…1Aw/0…100%RH

    LCD 3-linealphanumericwithtrendindicators

    Clock Realtimeclockprovidesatimestampforeverymeasurement

    Currentconsumption Max.20mA(backlightON)

    IPprotectionclass IP30

    CE/EMCconform EMC2008/108/EG

    FDA/GAMP FDA21CFRpart11/GAMP5

    Dimensions/Weight 188x72x30mm/200g

    Material ABS

    HygroPalm23-AW-A

    Field applicationTheHygroPalmHP23-AW-Aofferstheperfectsolutionforon-sitewateractivitymeasure-

    mentstoconfirmproductstabilityandindicateshelflife.TheHP23-AW-Aissuitable

    asamobilelaboratoryunit.EqualtotheHygroLabC1theHP23-AW-Aisperfectasa

    portableanalyzerwithtwoprobeinputsforanysuitableHC2probe.TheHP23-AW-Acan

    alsobeusedinconjunctionwithHW4-P-QUICK-Vx.

    Portable and convenientHandheldinstrumentspeciallyconfiguredtosuitthewateractivityuser.Itincludesmany

    oftheadvancedfeaturesoftheHygroLabC1,butinaconvenientportableconfiguration.

    Features• 2inputchannelsforHC2stationprobesorHC2insertionprobescanbeconnected

    formeasurementofwateractivity,relativehumidityandtemperature

    • AwQuickfunctionforfastmeasurementresults(typically4-5minutes)

    • Audiblealarmtoindicatecompletedmeasurement

    • Savesupto10,000datarecordswith%RH,°C/°F,dateandtime

    • Batterychargingfunction

    Compatible products

    Wateractivityprobe: HC2-AW

    Insertionprobe: HC2-P05,HC2-HP28,HC2-HP50

  • WATER ACTIVITY

    Aw Insertion probes

    For direct measurementTheinsertionprobesarefordirectmeasurementofwateractivityinbulk

    samples.Applicationsincludepowders,granules,grainandcereals.

    HC2-HPinsertionprobesfeaturearobust10mmdiameterstainlesssteel

    probewithreplaceablesinteredsteeldustfilterformeasurementindust

    bulkmaterial.

    Fordustfreeapplicationsliketablets,gelcapsules,grainandplastic

    granulestheHC2-P05fitsperfectlywithitslasercutslots.

    Features• 5mminsertionprobeformeasurement

    indust-freebulkmaterials

    • 10mminsertionprobeformeasurement

    industybulkmaterials

    HC2-HP28/50probe

    HC2-P05probe

    Order code HC2-P05 HC2-HP28 HC2-HP50

    Probelength Ø5x200mm Ø10x280mm Ø10x500mm

    Forusewith HygroLabC1,HP23-AW-A

    Accuracyat23°C±5K(73.4°F) ±0.015Aw/1.5%RH/±0.3K ±0.008Aw/0.8%RH/±0.1K

    Temperaturedependence 0.001K/K,0.02%rh/K

    Sensor HYGROMER®IN-1/Pt-100,1/3DINClassB

    Longtermstability

  • WATER ACTIVITY

    Station probe HC2-AW-USB

    Multi station applicationThenewstationprobeHC2-AW-USBoffersnewpossibilities.TheUSB

    probecanbedirectlyconnectedtoaPCrunningHW4-P-QUICK-Vxsoftware

    enablingwateractivitymeasurementcapability.TheHC2-AW-USBisthe

    perfectdeviceforamultistationapplication,asmultipleprobescanbe

    attachedtoasinglePC.

    USB station probesUSBprobescanbeorderedassingleprobeorasasetincludingtheHW4

    softwarewithAwQuickfunction.Thesetoffersallpossibilitiestomeasu-

    rewateractivity.

    Features• CompletesetofprobeandHW4includingAwQuickfunctionavailable

    • Measurementrange:

    0.00…1.00Aw(0…100%RH),-40…85°C(-40..185°F)

    • USBinterfacefordirectconnectiontoaPC(HC2-AW-USB)

    Typical accessoriesSampleholders: WP-14-S,WP-40,WP-40TH

    Disposablesamplecontainer: PS-14(14mmdeep),PS-40(40mmdeep)

    Note: Ordersamplecontainersseparately. Sampleholderscanalsobeusedascalibrationdevice.

    Order code HC2-AW-USB HC2-AW-USB-SW

    Probetype MeasurementprobewithUSBinterface Measurementprobeandsoftware

    HW4-P-QUICK-Vx

    Connection ViaUSBtoPC,3mcable

    Forusewith SoftwareHW4

    Accuracyat23°C±5K(73.4°F) ±0.008Aw/±0.8%RH/±0.1K

    Temperaturedependence 0.001K/K,0.0002Aw/K

    Sensor HYGROMER®WA-1/Pt-100,1/3DINClassB

    Calculations Deworfrostpoint

    Longtermstability

  • WATER ACTIVITY

    Aw-SetsTheROTRONICAwstarterkitsincludeeverythingneededformeasurementand

    calibration.Theportableunitsaresuppliedinarobustcarrycase.

    Bench-top kit:Order code HygroLab C1-SET-40

    Setcontent Benchtopdisplaydevice: HygroLabC1Including:

    -PoweradapterAC->DC12V-HW4softwarewithAw-Quick

    Measurementprobe HC2-AW

    USB-CableforPCconnection AC0002

    Sampleholder: WP-40

    Disposablesamplecontainer(100pc.) PS-14

    Disposablesamplecontainer(100pc.) PS-40

    Humiditystandards0.5%RH EA00-SCS

    Humiditystandards10%RH EA10-SCS

    Humiditystandards35%RH EA35-SCS

    Humiditystandards50%RH EA50-SCS

    Humiditystandards80%RH EA80-SCS

    Handheld kit:Order code HP23-AW-A-SET-14 with14mmsampleholder

    Setcontent Handheldinstrument HP23-AW-A

    Measurementprobe HC2-AW

    Sampleholder WP-14-S

    Disposablesamplecontainer(10pc.) PS-14

    Humiditystandards10%RH EA10-SCS

    Humiditystandards35%RH EA35-SCS

    Humiditystandards50%RH EA50-SCS

    Humiditystandards80%RH EA80-SCS

    Carrycase AC1124

    Order code HP23-AW-A-SET-40 with40mmsampleholder

    Setcontent Handheldinstrument HP23-AW-A

    Measurementprobe HC2-AW

    Sampleholder WP-40

    Disposablesamplecontainer(10pc.) PS-40

    Humiditystandards10%RH EA10-SCS

    Humiditystandards35%RH EA35-SCS

    Humiditystandards50%RH EA50-SCS

    Humiditystandards80%RH EA80-SCS

    Carrycase AC1124

  • WATER ACTIVITY

    Aw Accessories

    Sample holders and sample containersThe sample holders provide excellent sample containment and optimum temperature stability. The WP-40TH can be attached

    toawaterbathforadditionaltemperaturecontrol.

    Thedisposablesamplecontainersensuretheoptimumsamplevolumeisintroducedintothesampleholders.Theypreventthe

    sampleholdersfromcomingintodirectcontactwiththeproductbeingtested,therebypreventingsoilingorcrosscontamination.

    Thesamplecontainersalsoprovideaconvenientmeansofcollectingandstoringsamples.

    Sample holdersOrder code WP-14-S WP-40 WP-40TH

    Type Sampleholder

    Usewith PS-14 PS-14/PS-40 PS-14/PS-40

    Height 14mm 40mm 40mm

    Material V2Asteel Brass,nickel-plated

    Weight 350g 1250g 1550g

    Sample holdersOrder code PS-14 PS-40

    Type Samplecontainer

    Usewith WP-14-SWP-40/WP-40TH WP-40/WP-40TH

    Height 14mm 40mm

    Packagingunit 100pc.

    Clamp sealing mechanismInthecaseofverydryorverymoistsamplesadditionalmechanicalsealingoftheAwmeasurement

    probeandsampleholdermaybenecessarytopreventexternalconditionsinfluencingthesample.

    Order code AW-KHS

    Usewith WP-40/WP-40TH

    Weight 1100g

  • WATER ACTIVITY

    HW4 Software

    Fully compatibleTheHW4softwareiscompatiblewithallROTRONICproductswithUSB,UARTorEthernet

    interface.TheHW4softwareisWINDOWS7compatibleandrunson64bitPCsystems.

    Itenablesusefulfunctionslike:

    • Livedisplayofcurrentmeasurements

    • Recordingofmeasurementdata

    • Instrumentconfiguration

    • Probecalibration

    • Onlinecalculationofanyhumidityormoistureparameter

    • Alarmswithnotificationcanbesentviae-mailorSMStext

    • AwQuickfunctionincluded(HW4-P-QUICK-Vx)

    Viewing of measured values/monitoringViewingofmeasuredvaluesisveryeasyanduser-friendly.Filesofanydeviceshownin

    thedevicetreecanbecopiedandopeneddirectlywiththeHW4explorer.Thedatais

    presentedintableorgraphform.Thegraphmodulecanbeconfiguredbytheuser.

    Instrument configurationHW4softwarecanbeusedtoadjustthesettingsofROTRONICinstrumentsandprobes.

    Thefollowingfunctionsandsettingscanbechanged:

    • Generaldevicesettings

    • Passwordprotectionofdevicesettings

    • Changeofunitsystemsmetric/english

    • Awmodesettings

    Humidity standardsOn-sitecalibrationandadjustmentofROTRONICprobes.Withthehumiditystandards,

    acalibrationdeviceandHW4softwarerunningonaPCthisiseasilyachieved.Itisalso

    possibletocalibrateandadjustprobeswiththeHygroLabC1orHP23-AW-A.

    Order code Humidity value Uncertainty at 23 °C (73.4 °F)

    EA00-SCS 0.5%RH ±0.3%RH

    EA05-SCS 5%RH

    EA10-SCS 10%RH

    EA20-SCS 20%RH

    EA35-SCS 35%RH ±0.5%RH

    EA50-SCS 50%RH ±0.9%RH

    EA60-SCS 60%RH

    EA75-SCS 75%RH

    EA80-SCS 80%RH ±1.2%RH

    EA95-SCS 95%RH

  • 5903

    0E/2

    012-

    05

    ROTRONIC WORLDWIDE

    ROTRONICispresentinmorethan40countriesworldwide.Youwillalwaysfindacompleteandup-to-date

    listofourpartnersatwww.rotronic.com/international.

    ROTRONICInternational

    ROTRONICPartners

    SINGAPOREROTRONIC South East Asia Pte Ltd16KallangPlace#07-04Singapore339156Telephone+6562946065Fax+6562946096www.rotronic.com.sg

    UKROTRONIC Instruments UK Ltd.CromptonFields,CromptonWayCrawley,WestSussexRH109EEPhone+441293571000Fax+441293571008www.rotronic.co.uk

    FRANCEROTRONIC Sarl56,Bld.deCourcerin,F-77183Croissy-BeaubourgTelephone+33160950710Fax+33160171256Www.rotronic.fr

    CHINAROTRONIC Shanghai Rep. Office2B,ZaoFongUniverseBuilding,No.1800ZhongShanWestRoad,Shanghai200233,ChinaTelephone+864008162018Fax+861082254374www.rotronic.cn

    ITALYROTRONIC Italia srlViaRepubblicadiSanMarino1I-20157MilanoTelephone+3902-39.00.71.90Fax+3902-33.27.62.99www.rotronic.it

    SWITZERLANDROTRONIC AGGrindelstrasse6,CH-8303BassersdorfPhone+41448381144Fax+41448370073www.rotronic.ch

    GERMANYROTRONIC Messgeräte GmbHEinsteinstrasse17–23,D-76275EttlingenPhone+497243383250Fax+497243383260www.rotronic.de

    USAROTRONIC Instrument Corp.Suite150,135EngineersRoad,Hauppauge,NY11788Telephone+16314273898Fax+16314273902www.rotronic-usa.com