Water Heater Optitherm Bock ASME

Embed Size (px)

DESCRIPTION

Water Heater Optither

Citation preview

  • 5155 West Patrick Lane, Suite 200 Las Vegas, NV 89118 Office 702.940.3400 Fax 702.940.3419 www.inviewlabs.com P a g e | 1

    REVIT CONTENT GUIDE Manufacturer: Bock Description: Optitherm Natural Gas Water Heater File: Water_Heater-Optitherm-Bock-ASME.rfa Type Catalog: Not Applicable Rendering file: Not Applicable Schedule file: Schedule - Water_Heater-Optitherm-Bock-ASME.rvt

    Instance Properties

    Type Properties

  • 5155 West Patrick Lane, Suite 200 Las Vegas, NV 89118 Office 702.940.3400 Fax 702.940.3419 www.inviewlabs.com P a g e | 2

    Loading and placing into the Project: One Mechanical Equipment family is supplied and can be loaded into a Revit project through all traditional methods. The family has no supporting files. The display model requires a host to be placed within the project (i.e. wall, ceiling or floor). Also, ensure that the visibility settings within the project have been edited to show Mechanical Equipment. The familys origin point is in the center of the mounting surface.

    Project Behavior: Instance Parameters: In the Instance Parameters, the user can control the following options:

    Water Flow For inputting anticipated intake gallons per minute. Drain Flow For inputting anticipated drain gallons per minute. Supply Air Flow For inputting anticipated air supply CFM. Exhaust Air Flow For inputting anticipated air exhaust CFM. Water Pressure Drop For inputting anticipated water pressure drop. Supply Air Pressure Drop For inputting anticipated supply air pressure drop. Gas Pressure Drop For inputting anticipated supply gas pressure drop. Exhaust Air Pressure Drop For inputting anticipated exhaust air pressure drop.

    Type Parameters: Each type represents a manufactured product. Therefore, the type parameters should not be modified. Please note:

    Product Documentation Link Directs a webpage to the products online listing. Equipment Abbreviation For filtering schedules. *See scheduling description below.

    The family contains three (3) types whose values do not need to be modified by the user for standard configuration. Examples of type names: 300,000 BTU/HR Rated Input 400,000 BTU/HR Rated Input

    500,000 BTU/HR Rated Input Within the type properties dialogue box the user will find useful information for scheduling purposes such as Height, Width, Inputs and Outputs, and other unique properties of the family. In Identity Data the user will find information specific to Bock and the model, i.e.: family revision information, Bock copyright information, part description, product URL and other specific data. *See scheduling description below.

    Visibility: For best performance, all model geometry is turned off in Plan view and represented through masking regions and symbolic lines that update automatically when a user adjusts the accessories and their modifiers. For maximum usability, all geometry is also assigned the subcategory: Mechanical Equipment.

    Rendering: When the family file is loaded into the project, standard Bock materials are imported. These may be modified, though ensure that the modification selection matches an actual manufacturer supplied option.

  • 5155 West Patrick Lane, Suite 200 Las Vegas, NV 89118 Office 702.940.3400 Fax 702.940.3419 www.inviewlabs.com P a g e | 3

    Scheduling & BOM creation: Bock products may be scheduled utilizing the schedule view in the given project file. Select and copy (Ctrl-C) the schedule from the sheet view and paste it (Ctrl-V) into a sheet in your project. The schedule filters are set to look for only those units designated with Manufacturer as Bock and Equipment Abbreviation as WH. The schedules contain special functionality for displaying the configured order numbers of the different selected types.