1
©2017 Waters Corporation. Waters, T he Science of W hat's Possible, XBridge, XSelect, CORT ECS, ACQUITY UPLC, ACQUITY, Arc, and Alliance are registered trademarks of Waters Corporation. BEH Technology, CSH, and VanGuard are trademarks of Waters Corporation. All other trademarks are the property of their respective owners. February 2017 720001983EN KP-SIG Waters UPLC, UHPLC, and HPLC Column Selection and Mobile-Phase Guide [ www.waters.com ] High retentivity for basic compounds Excellent peak shape at elevated pH Good universal column choice for a wide variety of compounds Stable across a wide pH range For separations at high temperatures (80 °C) High retentivity for polar organic compounds and metabolites Balanced retention of polar and hydrophobic analytes High strength silica for mechanical stability Maximum efficiency Increased sensitivity Seamless scalability from UPLC® to UHPLC to HPLC Good separations for basic compounds under low pH conditions Excellent MS performance with formic acid as a mobile-phase modifier Fast pH switching and column equilibration BEH Technology HSS Technology The Importance of Mobile-Phase pH Benchmarking System Performance Benchmarking System Performance Dependence of Retention on pH: Reversed-Phase Retention Map Versatility of Neutrals QC Reference Material Using a guard column is an economical way to prolong analytical column lifetime without compromising chromatographic performance. VanGuard™ Column Protection Products are available in a wide selection of particle sizes and stationary phases making them ideally suited for the physical and chemical protection for all analytical columns. Minimal chromatographic effects and optimized performance Superior column protection for UPLC, UHPLC, and HPLC Columns and Sorbents with particle sizes ranging from 1.6 mm to 5 mm Compatible operating pressures up to 18,000 psi (1240 bar) Selection Guide VanGuard Column Protection Cartridge/Pre-column selection based on analytical column I.D. Column I.D. Particle Size VanGuard Format VanGuard Dimension 2.1 mm <2 µm Pre-column 2.1 x 5 mm 2.1 mm >2 µm Cartridge Column 2.1 x 5 mm 3.0 mm >2 µm Cartridge Column 2.1 x 5 mm 3.9 mm >2 µm Cartridge Column 3.9 x 5 mm 4.6 mm >2 µm Cartridge Column 3.9 x 5 mm Mobile-Phase Chemical pK a Buffer Range Formula Volume or Mass Required for 10 mM Mobile-Phase Concentration (per 1 L) pH Adjustment Acid/Base MS Compatible? Acetic Acid (glacial) 4.8 CH 3 COOH 0.571 mL ü Ammonium Acetate pK a 1 4.8 3.8-5.8 CH 3 COONH 4 0.770 g CH 3 COOH or NH 4 OH ü Ammonium Acetate pK a 2 9.2 8.2-10.2 CH 3 COONH 4 0.770 g CH 3 COOH or NH 4 OH ü Ammonium Bicarbonate 9.2, 10.3 (8.2-11.3) NH 4 HCO 3 0.790 g HCOOH or NH 4 OH ü Ammonium Formate pK a 1 3.8 2.8-4.8 NH 4 COOH 0.640 g HCOOH or NH 4 OH ü Ammonium Formate pK a 2 9.2 8.2-10.2 NH 4 COOH 0.640 g HCOOH or NH 4 OH ü Ammonium Hydroxide 9.2 NH 4 OH 0.675 mL ü Ammonium Phosphate, Dibasic 7.2, 9.2 (6.2-10.2) (NH 4 ) 2 HPO 4 1.32 g H 3 PO 4 or NH 4 OH O Formic Acid 3.8 HCOOH 0.420 mL ü N-Methylpyrrolidine 10.3 C 5 H 11 NO 1.04 mL ü Phosphoric Acid 2.1 H 3 PO 4 0.580 mL O Potassium Phosphate, Monobasic 2.1 (1.1-3.1) KH 2 PO 4 1.36 g H 3 PO 4 or KOH O Potassium Phosphate, Dibasic 7.2 (6.2-8.2) K 2 HPO 4 1.74 g H 3 PO 4 or KOH O Potassium Phosphate, Tribasic 12.7 (11.7-13.7) K 3 PO 4 2.12 g H 3 PO 4 or KOH O Pyrrolidine 11.3 C 4 H 9 N 0.833 mL ü Sodium Borate 9.1, 12.7, 13.8 (8.2-14) Na 2 B 4 O 7 2.01 g H 3 BO 4 or NaOH O Sodium Citrate, Tribasic 3.1, 4.8, 6.4 (2.1-7.4) HOC(COONa)(CH 2 COONa) 2 2.58 g Citric Acid or NaOH O Triethylamine (TEA) 11.01 (CH 3 CH 2 ) 3 N 1.39 mL ü Triethylammonium Acetate (TEAA) pK a 1 4.76 3.8-5.8 (CH 3 CH 2 ) 3 N:CH 3 COONH 4 (1:2) 0.695 mL TEA/0.571 mL Acetic Acid TEA or CH 3 COOH ü Triethylammonium Acetate (TEAA) pK a 2 11.01 10.0-12.0 (CH 3 CH 2 ) 3 N:CH 3 COONH 4 (2:1) 1.39 mL TEA/0.285 mL Acetic Acid TEA or HCOOH ü Triethylammonium Formate (TEAF) pK a 1 3.75 2.8-4.8 (CH 3 CH 2 ) 3 N:NH 4 COOH (1:2) 0.695 mL TEA/0.420 mL Formic Acid TEA or HCOOH ü Triethylammonium Formate (TEAF) pK a 2 11.01 10.0-12.0 (CH 3 CH 2 ) 3 N:NH 4 COOH (2:1) 1.39 mL TEA/0.210 mL Formic Acid TEA or HCOOH ü Trifluoroacetic Acid (TFA) 0.3 CF 3 COOH 0.743 mL ü 0.770 0.800 0.830 0 10 20 30 40 50 60 70 Upper Control Limit Center Line Lower Control Limit Sample Quality Characteristic Peak ID: 1. Acetone, 2. Naphthalene, 3. Acenaphthene. HSS C18 Silica Particle CSH C18 Charged Surface Hybrid Particle BEH C18 Hybrid Particle CORTECS C18 Solid-Core Particle 1 2 3 AU 0.0 0.1 0.2 AU AU 0.0 0.1 0.2 AU 0.0 0.1 0.2 0 1 2 3 4 5 6 7 min 0.0 0.1 0.2 0.3 1 1 1 2 2 2 3 3 3 0 1 2 3 4 5 6 7 min Non-ionized form of acids and bases give most retention. Retention of neutral analytes not affected by pH. Silica pH Range Hybrid Particle pH Range pH 0 5 10 15 20 25 30 35 40 0 2 4 6 8 10 12 Retention Factor (k) Acid Base Neutral Increased base retention [B] Increased acid retention [HA] Analyte pK a The Importance of Mobile-Phase pH: Rapid Method Development 1 2 6 3 5 4 2 3 1 4 6 5 0 1 2 3 4 5 6 7 8 min 3 2 4 6 5 1 Compounds: 1. Doxylamine (BASIC) 2. Benzamide (NEUTRAL) 3. Hydroxyisophthalic Acid (ACIDIC) 4. Doxepin (BASIC) 5. Flavone (NEUTRAL) 6. Fenoprofen (ACIDIC) pH 2 pH 7 pH 12 Mobile-Phase pH Enhances Selectivity for: Acids Bases Neutrals Note: The provided data is for reference only and is based on nominal values for unmodified systems. Any adjustment to the plumbing, connectivity, and configuration of the system will change the instrument bandspread and will influence the resulting chromatography. Alliance HPLC ACQUITY Arc ACQUITY UPLC H-Class System HPLC UHPLC UPLC Dispersion >40 µL 22–29 µL <15 µL Particle Size 3–5 µm 2–3 µm <2 µm Routine Pressure <4000 psi <10,000 psi <18,000 psi Column I.D. 4.6 mm (3.0 mm) 3.0 mm (2.1 mm) 2.1 mm (1.0 mm) Column Length 75–250 mm 50–150 mm ≤150 mm Optimized column dimension matched to Waters LC Systems. Column Selection Guide System LC Technique Bandspread* Recommended Column Particle Sizes and I.D.s Shimadzu Prominence UFLC HPLC 41 μL XBridge 3.5, 5 µm; XSelect 3.5, 5 µm; CORTECS 2.7 µm 3.0–4.6 mm I.D. Alliance 2695 HPLC HPLC 29 μL Agilent 1260 UHPLC (600 bar) HPLC 28 μL Thermo Accela UHPLC HPLC 21 μL XBridge 2.5, 5 µm; XSelect 2.5, 5 µm; CORTECS 2.7 µm 3.0 mm I.D. Agilent 1290 UHPLC (1200 bar) UHPLC 17 μL ACQUITY Arc UHPLC 23 μL XBridge 2.5, 5 µm; XSelect 2.5, 5 µm; CORTECS 2.7 µm 3.0 mm I.D. ACQUITY UPLC UPLC 12 μL ACQUITY UPLC BEH 1.7 µm; ACQUITY UPLC CSH 1.7 µm; CORTECS 1.6 µm 2.1 mm I.D. ACQUITY UPLC H-Class w/Column Manager UPLC 12 μL ACQUITY UPLC H-Class UPLC 9 μL Using a wide mobile-phase pH range is an effective approach to change compound selectivity. Increase selectivity for: - Acids (Peaks 3 and 6) - Bases (Peaks 1 and 4) Neutrals (Peaks 2 and 5) are largely unaffected by mobile-phase pH. The pH of the mobile phase has the greatest impact on analyte retention. For the most robust separations, choose a mobile-phase pH that corresponds to the plateau regions of the retention map. Use Waters Quality Control (QC) Reference Materials to evaluate or verify key performance criteria with data generated when the system is known to be in good working order. The criteria chosen, along with the routine use of a control chart, provides an understanding of the capability of your system and can be a useful troubleshooting tool. Typical Criteria 1. Retention time range or reproducibility 2. Peak area range or reproducibility 3. Peak tailing range 4. Peak resolution 5. Response 6. System pressure Instrument bandspread is one of the most practical LC instrument parameters to understand when transferring LC methods. Knowing the result of this simple measurement gives the separation scientist the ability to develop compatible methods that are independent of the LC instrument manufacturer. The following table gives recommendations on column configuration based on nominal instrument bandspread values. CSH Technology Solid-Core Technology Wide pH Range BEH C18 UPLC: 1.7 µm / UHPLC: 2.5 μm / HPLC: 3.5, 5, 10 µm O Si O O Performance Benefits: General purpose column ideally suited for method development due to extreme pH stability and applicability to the broadest range of compound classes. Bonding: Trifunctional C 18 , fully end-capped, bonded to Ethylene Bridged Hybrid (BEH) substrate. BEH C8 UPLC: 1.7 µm / UHPLC: 2.5 μm / HPLC: 3.5, 5, 10 µm O Si O O Performance Benefits: General purpose column ideally suited for method development due to extreme pH stability and applicability to the broadest range of compound classes. Bonding: Trifunctional C 8 , fully end-capped, bonded to Ethylene Bridged Hybrid (BEH) substrate. BEH Shield RP18 UPLC: 1.7 µm / UHPLC: 2.5 μm / HPLC: 3.5, 5, 10 µm O Si CH Polar Group 3 CH 3 Performance Benefits: Alternate selectivity compared to straight chain C 18 , particularly with phenolic analytes. Compatible with 100% aqueous-phase composition. Bonding: Monofunctional embedded polar C 18 , fully end- capped, bonded to Ethylene Bridged Hybrid (BEH) substrate. BEH Phenyl UPLC: 1.7 µm / UHPLC: 2.5 μm / HPLC: 3.5, 5 µm O Si O O Performance Benefits: Excellent method development column for alternate selectivity, particularly in regard to polyaromatic compounds. Unique level of pH stability for a Phenyl bonded phase. Bonding: Trifunctional C 6 Phenyl, fully end-capped, bonded to Ethylene Bridged Hybrid (BEH) substrate. BEH HILIC UPLC: 1.7 µm / UHPLC: 2.5 μm / HPLC: 3.5, 5 µm Performance Benefits: Excellent for retention of very polar, basic, water soluble analytes. Specifically designed and tested for HILIC separations using mobile phases containing high concentrations of organic solvent. Bonding: Unbonded Ethylene Bridged Hybrid (BEH) substrate. BEH Amide UPLC: 1.7 µm / UHPLC: 2.5 μm / HPLC: 3.5, 5 µm O Si O O O NH 2 Linker Performance Benefits: Rugged HILIC stationary phase designed to separate a wide range of very polar compounds. Especially good at separating carbohydrates (saccharides) using high concentrations of organic modifier, elevated temperature, and high pH. Compatible with all modern detectors including MS, ELSD, UV, and fluorescence. Bonding: Trifunctional amide bonded to Ethylene Bridged Hybrid (BEH) substrate. C18+ UPLC: 1.6 µm / UHPLC:: 2.7 μm O Si O O Performance Benefits: General purpose reversed-phase column designed to maximize efficiency. A charged-surface-silica-solid-core particle enables excellent peak shape for basic compounds at low pH, especially in low concentration modifier mobile phases. Offers complementary selectivity to traditional C 18 columns. Bonding: Trifunctional C 18 ligand, fully end-capped, bonded to a charged surface silica solid-core particle substrate. C18 UPLC: 1.6 µm / UHPLC: 2.7 μm O Si O O Performance Benefits: General purpose reversed-phase column designed to maximize efficiency. Balanced retention of acids, bases, and neutrals at low- and mid-range pH. Bonding: Intermediate coverage trifunctional-C 18 ligand, fully end-capped, bonded to a silica solid-core particle substrate. T3 UPLC: 1.6 µm / UHPLC: 2.7 μm O Si O O Performance Benefits: Aqueous mobile-phase compatible column designed to maximize efficiency. Provides balanced retention for both polar and non-polar compounds. Bonding: T3 (C 18 ) bonding and endcapping, bonded to a silica solid-core particle substrate C8 UPLC: 1.6 µm / UHPLC: 2.7 μm O Si O O Performance Benefits: General purpose column designed to maximize efficiency. Similar selectivity, but shorter retentivity when compared to typical C 18 phases. Bonding: Trifunctional C 8 , fully end-capped, bonded to a silica solid-core particle substrate. Shield RP18 UPLC: 1.6 µm / UHPLC: 2.7 μm O Si CH Polar Group 3 CH 3 Performance Benefits: Excellent method development column designed to give maximum efficiency. Alternative selectivity when compared to typical C 18 phases, especially phenolic compounds. Bonding: Monofunctional embedded polar C 18 , fully end- capped, bonded to a silica solid-core particle substrate. Phenyl UPLC: 1.6 µm / UHPLC: 2.7 μm O Si O O Performance Benefits: Excellent method development column designed to give maximum efficiency as well as alternate selectivity, particularly in regard to polyaromatic compounds. Bonding: Trifunctional C 6 Phenyl, fully end-capped, bonded to a silica solid-core particle substrate. HILIC UPLC: 1.6 µm / UHPLC: 2.7 μm Performance Benefits: High efficiency column designed for retention of extremely polar, basic, water-soluble analytes. Bonding: Unbonded high-purity silica solid-core particle substrate. Wide Selectivity Range High Efficiency CSH C18 UPLC: 1.7 µm / UHPLC: 2.5 μm / HPLC: 3.5, 5, 10 μm O Si O O Performance Benefits: General purpose reversed-phase column that offers excellent pH stability and rapid mobile-phase re-equilibration for method development. Charged Surface Hybrid (CSH™) Technology enables superior peak shape and increased loading capacity for basic compounds. Bonding: Trifunctional C 18 ligand, fully end-capped, bonded to a Charged Surface Hybrid (CSH) particle substrate. CSH Phenyl-Hexyl UPLC: 1.7 µm / UHPLC: 2.5 μm / HPLC: 3.5, 5 µm O Si O O Performance Benefits: General purpose alternative selectivity ligand that provides pi-pi interactions with polyaromatic compounds, while maintaining excellent reproducibility at pH extremes. Charged Surface Hybrid (CSH) Technology enables superior peak shape and increased loading capacity for basic compounds. Bonding: Trifunctional C 6 Phenyl ligand, fully end-capped, bonded to a CSH particle substrate. CSH Fluoro-Phenyl UPLC: 1.7 µm / UHPLC: 2.5 μm / HPLC: 3.5, 5 µm O Si F F F F F O O Performance Benefits: General purpose column that provides a very high degree of analyte selectivity, especially when using low-pH mobile phases. Charged Surface Hybrid (CSH) Technology enables superior peak shape and increased loading capacity for basic compounds. Bonding: Trifunctional propyl fluorophenyl ligand, non-end-capped, bonded to a CSH particle substrate. HSS C18 UPLC: 1.8 µm / UHPLC: 2.5 μm / HPLC: 3.5, 5 µm O Si O O Performance Benefits: Ultra performance C 18 chemistry, increased retention, superior peak shape, resists acid hydrolysis at low pH. Bonding: High coverage trifunctional C 18 , fully end-capped, bonded to a High Strength Silica (HSS) particle substrate. HSS C18 SB UPLC: 1.8 µm / UHPLC: 2.5 μm / HPLC: 3.5, 5 µm O Si O O Performance Benefits: Unique, non-end-capped C 18 chemistry designed specifically for method development scientists. Offers unique Selectivity for Bases (SB) when operating under low-pH conditions. Bonding: Intermediate coverage trifunctionally bonded C 18 , no endcapping, bonded to High Strength Silica (HSS) particle substrate. HSS T3 UPLC: 1.8 µm / UHPLC: 2.5 μm / HPLC: 3.5, 5 µm O Si O O Performance Benefits: Aqueous mobile-phase compatible column designed for exceptional polar compound retention. Bonding: T3 (C 18 ) bonding and endcapping, bonded to High Strength Silica (HSS) particle substrate. HSS PFP UPLC: 1.8 µm / UHPLC: 2.5 μm / HPLC: 3.5, 5 µm O Si F F F F F O O Performance Benefits: A general purpose column designed to maximize selectivity differences for Lewis bases through pi-pi interactions. The rigid aromatic ring provides additional selectivity based on shape, dipole moment, and hydrogen bonding interactions. Bonding: Trifunctional pentafluorophenyl ligand, non-end-capped, bonded to High Strength Silica (HSS) substrate. HSS CN UPLC: 1.8 µm / UHPLC: 2.5 μm / HPLC: 3.5, 5 µm O Si CN Performance Benefits: A general purpose column that shows contrasting analyte selectivity when compared to C 18 phases. This column can be used for both reversed- phase and normal-phase separations. Bonding: Sterically hindered, mono-functional cyano-propyl ligand, non-end-capped, bonded to High Strength Silica (HSS) substrate. The choice of stationary phase influences the selectivity of the separation. The bonded phases and particle substrates used in Waters® HPLC Columns are developed to maximize the differences in analyte retention to help resolve the most demanding separation challenges. BEH C 18 BEH Shield RP18 BEH Phenyl HSS T3 HSS C 18 HSS C 18 SB HSS CN CSH Phenyl-Hexyl CSH Fluoro-Phenyl CSH C 18 BEH C 8 Conditions: Columns: 2.1 x 100 mm Mobile phase: 72% water/28% methanol (v/v) Flow rate: 0.5 mL/min Injection vol.: 5.0 µL Sample conc.: 10 µg/mL Temperature: 50 °C Detection: UV @ 254 nm Sampling rate: 20 pts/sec Time constant: 0.1 min Instrument: ACQUITY UPLC® with PDA Detector Compounds [EPA 8330 Standard Mixture): 1. HMX 2. RDX 3. 1,3,5-Trinitrobenzene 4. 1,3-Dinitrobenzene 5. Nitrobenzene 6. Tetryl 7. 2,4,6-Trinitrotoluene 8. 2-Amino-4,6-Dinitrotoluene 9. 4-Amino-2,6-Dinitrotoluene 10. 2,4-Dinitrotoluene 11. 2,6-Dinitrotoluene 12. 2-Nitrotoluene 13. 4-Nitrotoluene 14. 3-Nitrotoluene 0 2 4 6 8 10 12 14 16 18 20 min Comparative separations may not be representative of all applications. CORTECS Phenyl CORTECS C 8 CORTECS C 18 CORTECS C 18 + HSS PFP CORTECS UPLC T3 CORTECS UPLC Shield RP18 7,8 5,6 3 4,5 2 1 7 10,11,12,13,14 9,8 6 6,7 8,9 3 4 5 6 7 8 9,10,11 12 13 14 2,3 6 7 8 9,10,11 8,9,13 7 10 11 6 14 12 1 4 3 5 2 7 8 10 9 11 6 14 13 12 8 7 10 9 11 6 4 3 5 8 7 10,11 9 6 14 13 12 1 4 5 3 12,13 14 2 1 4 3 5 2 1 2 1 4 3 5 2 1 9,10,11 12 5 2 1 4 3 6 2 1 4 3 5 2 1 4 3 7 2 14 13 12 10,11 1 4 5 12,13,14 13 14 12 13 14 6 7 10 8 9 11 10 8 9 11 12 13 14 1 2,3 4 5 7 9 6 11 10 12 8,13 14 1 2 3 4 7 10 5 6 11 14 8 9, 13 12 1 2 3 4 7 10 5 8 9 6 11 12 13 14 1 2 3 4 5 6 7, 8 9 11 10 12 13 14 1 2 3 4 5 6 9 11 10 12 13 14 7 8 1 2 3 4 5 12 14 13 11 10 6 9 7,8 1 2 3 4 5 7 6 10 11 13 12,8, 9 14 Selectivity Choices Nitroaromatic Compounds Extend Column Performance and Lifetime

Waters UPLC, UHPLC, and HPLC Column Selection and Mobile … · 2017-02-15 · Neutrals (Peaks 2 and 5) are largely unaffected by mobile-phase pH. The pH of the mobile phase has the

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Waters UPLC, UHPLC, and HPLC Column Selection and Mobile … · 2017-02-15 · Neutrals (Peaks 2 and 5) are largely unaffected by mobile-phase pH. The pH of the mobile phase has the

©2017 Waters Corporation. Waters, The Science of What's Possible, XBridge, XSelect, CORTECS, ACQUITY UPLC, ACQUITY, Arc, and Alliance are registered trademarks of Waters Corporation. BEH Technology, CSH, and VanGuard are trademarks of Waters Corporation. All other trademarks are the property of their respective owners. February 2017 720001983EN KP-SIG

Waters UPLC, UHPLC, and HPLC Column Selection and Mobile-Phase Guide[ www.waters.com ]

■ High retentivity for basic compounds■ Excellent peak shape at elevated pH■ Good universal column choice for a wide

variety of compounds■ Stable across a wide pH range■ For separations at high temperatures

(80 °C)

■ High retentivity for polar organic compounds and metabolites

■ Balanced retention of polar and hydrophobic analytes

■ High strength silica for mechanical stability

■ Maximum efficiency■ Increased sensitivity■ Seamless scalability from UPLC® to

UHPLC to HPLC

■ Good separations for basic compounds under low pH conditions

■ Excellent MS performance with formic acid as a mobile-phase modifier

■ Fast pH switching and column equilibration

BEH Technology HSS Technology

The Importance of Mobile-Phase pH

Benchmarking System Performance

Benchmarking System Performance

Dependence of Retention on pH: Reversed-Phase Retention Map

Versatility of Neutrals QC Reference Material

Using a guard column is an economical way to prolong analytical column lifetime without compromising chromatographic performance. VanGuard™ Column

Protection Products are available in a wide selection of particle sizes and stationary phases making them ideally suited for the physical and chemical protection for all analytical columns.

■ Minimal chromatographic effects and optimized performance■ Superior column protection for UPLC, UHPLC, and HPLC Columns

and Sorbents with particle sizes ranging from 1.6 mm to 5 mm■ Compatible operating pressures up to 18,000 psi (1240 bar)

Selection Guide

VanGuard Column Protection Cartridge/Pre-column selection based on analytical column I.D.

Column I.D. Particle Size VanGuard Format VanGuard Dimension

2.1 mm <2 µm Pre-column 2.1 x 5 mm

2.1 mm >2 µm Cartridge Column 2.1 x 5 mm

3.0 mm >2 µm Cartridge Column 2.1 x 5 mm

3.9 mm >2 µm Cartridge Column 3.9 x 5 mm

4.6 mm >2 µm Cartridge Column 3.9 x 5 mm

Mobile-Phase Chemical pKaBuffer Range Formula Volume or Mass Required for

10 mM Mobile-Phase Concentration (per 1 L)pH Adjustment

Acid/BaseMS

Compatible?

Acetic Acid (glacial) 4.8 — CH3COOH 0.571 mL — üAmmonium Acetate pKa 1 4.8 3.8-5.8 CH3COONH4 0.770 g CH3COOH or NH4OH üAmmonium Acetate pKa 2 9.2 8.2-10.2 CH3COONH4 0.770 g CH3COOH or NH4OH üAmmonium Bicarbonate 9.2, 10.3 (8.2-11.3) NH4HCO3 0.790 g HCOOH or NH4OH üAmmonium Formate pKa 1 3.8 2.8-4.8 NH4COOH 0.640 g HCOOH or NH4OH üAmmonium Formate pKa 2 9.2 8.2-10.2 NH4COOH 0.640 g HCOOH or NH4OH üAmmonium Hydroxide 9.2 — NH4OH 0.675 mL — üAmmonium Phosphate, Dibasic 7.2, 9.2 (6.2-10.2) (NH4)2HPO4 1.32 g H3PO4 or NH4OH O

Formic Acid 3.8 — HCOOH 0.420 mL — üN-Methylpyrrolidine 10.3 — C5H11NO 1.04 mL — üPhosphoric Acid 2.1 — H3PO4 0.580 mL — O

Potassium Phosphate, Monobasic 2.1 (1.1-3.1) KH2PO4 1.36 g H3PO4 or KOH O

Potassium Phosphate, Dibasic 7.2 (6.2-8.2) K2HPO4 1.74 g H3PO4 or KOH O

Potassium Phosphate, Tribasic 12.7 (11.7-13.7) K3PO4 2.12 g H3PO4 or KOH O

Pyrrolidine 11.3 — C4H9N 0.833 mL — üSodium Borate 9.1, 12.7, 13.8 (8.2-14) Na2B4O7 2.01 g H3BO4 or NaOH O

Sodium Citrate, Tribasic 3.1, 4.8, 6.4 (2.1-7.4) HOC(COONa)(CH2COONa)2 2.58 g Citric Acid or NaOH O

Triethylamine (TEA) 11.01 — (CH3CH2)3N 1.39 mL — üTriethylammonium Acetate (TEAA) pKa 1 4.76 3.8-5.8 (CH3CH2)3N:CH3COONH4 (1:2) 0.695 mL TEA/0.571 mL Acetic Acid TEA or CH3COOH üTriethylammonium Acetate (TEAA) pKa 2 11.01 10.0-12.0 (CH3CH2)3N:CH3COONH4 (2:1) 1.39 mL TEA/0.285 mL Acetic Acid TEA or HCOOH üTriethylammonium Formate (TEAF) pKa 1 3.75 2.8-4.8 (CH3CH2)3N:NH4COOH (1:2) 0.695 mL TEA/0.420 mL Formic Acid TEA or HCOOH üTriethylammonium Formate (TEAF) pKa 2 11.01 10.0-12.0 (CH3CH2)3N:NH4COOH (2:1) 1.39 mL TEA/0.210 mL Formic Acid TEA or HCOOH üTrifluoroacetic Acid (TFA) 0.3 — CF3COOH 0.743 mL — ü

0.770

0.800

0.830

0 10 20 30 40 50 60 70

Upper Control Limit

Center Line

Lower Control Limit

Sample

Qua

lity

Cha

ract

eris

tic

Peak ID: 1. Acetone, 2. Naphthalene, 3. Acenaphthene.

HSS C18 Silica ParticleCSH C18 Charged

Surface Hybrid Particle

BEH C18 Hybrid ParticleCORTECS C18 Solid-Core Particle

1 2

3

AU

0.0

0.1

0.2

AUAU

0.0

0.1

0.2

AU

0.0

0.1

0.2

0 1 2 3 4 5 6 7 min

0.0

0.1

0.2

0.3

1

1

1

2

2 2

3

3 3

0 1 2 3 4 5 6 7 min

Non-ionized form of acids and bases give most retention. Retention of neutral analytes not affected by pH.

Silica pH Range

Hybrid Particle pH Range

pH

0

5

10

15

20

25

30

35

40

0 2 4 6 8 10 12

Ret

entio

n Fa

ctor

(k)

Acid

Base

Neutral

Increased base retention [B]Increasedacid retention [HA]

Analyte pKa

The Importance of Mobile-Phase pH: Rapid Method Development

1

2 63

54

23

1

465

0 1 2 3 4 5 6 7 8 min

3 2

46 5

1

Compounds:1. Doxylamine (BASIC)2. Benzamide (NEUTRAL)3. Hydroxyisophthalic Acid (ACIDIC)4. Doxepin (BASIC)5. Flavone (NEUTRAL)6. Fenoprofen (ACIDIC)

pH 2

pH 7

pH 12

Mobile-Phase pH Enhances Selectivity for: Acids Bases Neutrals

Note: The provided data is for reference only and is based on nominal values for unmodified systems. Any adjustment to the plumbing, connectivity, and configuration of the system will change the instrument bandspread and will influence the resulting chromatography.

Alliance HPLC ACQUITY Arc ACQUITY UPLC H-Class

System HPLC UHPLC UPLC

Dispersion >40 µL 22–29 µL <15 µL

Particle Size 3–5 µm 2–3 µm <2 µm

Routine Pressure <4000 psi <10,000 psi <18,000 psi

Column I.D. 4.6 mm (3.0 mm) 3.0 mm (2.1 mm) 2.1 mm (1.0 mm)

Column Length 75–250 mm 50–150 mm ≤150 mm

Optimized column dimension matched to Waters LC Systems.

Column Selection GuideSystem LC

Technique Bandspread* Recommended Column Particle Sizes and I.D.s

Shimadzu Prominence UFLC HPLC 41 μL XBridge 3.5, 5 µm; XSelect 3.5, 5 µm; CORTECS 2.7 µm 3.0–4.6 mm I.D.

Alliance 2695 HPLC HPLC 29 μLAgilent 1260 UHPLC (600 bar) HPLC 28 μL

Thermo Accela UHPLC HPLC 21 μL XBridge 2.5, 5 µm; XSelect 2.5, 5 µm; CORTECS 2.7 µm

3.0 mm I.D.Agilent 1290 UHPLC (1200 bar) UHPLC 17 μL

ACQUITY Arc UHPLC 23 μLXBridge 2.5, 5 µm; XSelect 2.5, 5 µm;

CORTECS 2.7 µm 3.0 mm I.D.

ACQUITY UPLC UPLC 12 μL ACQUITY UPLC BEH 1.7 µm; ACQUITY UPLC CSH 1.7 µm; CORTECS 1.6 µm

2.1 mm I.D.ACQUITY UPLC H-Class w/Column Manager UPLC 12 μL

ACQUITY UPLC H-Class UPLC 9 μL

■ Using a wide mobile-phase pH range is an effective approach to change compound selectivity.

■ Increase selectivity for: - Acids (Peaks 3 and 6) - Bases (Peaks 1 and 4)

■ Neutrals (Peaks 2 and 5) are largely unaffected by mobile-phase pH.

The pH of the mobile phase has the greatest impact on analyte retention. For the most robust separations, choose a mobile-phase pH that corresponds to the plateau regions of the retention map.

Use Waters Quality Control (QC) Reference Materials to evaluate or verify key performance criteria with data generated when the system is known to be in good working order. The criteria chosen, along with the routine use of a control chart, provides an understanding of the capability of your system and can be a useful troubleshooting tool.

Typical Criteria

1. Retention time range or reproducibility

2. Peak area range or reproducibility

3. Peak tailing range

4. Peak resolution

5. Response

6. System pressure

Instrument bandspread is one of the most practical LC instrument parameters to understand when transferring LC methods. Knowing the result of this simple measurement gives the separation scientist the ability to develop compatible methods that are independent of the LC instrument manufacturer. The following table gives recommendations on column configuration based on nominal instrument bandspread values.

CSH Technology Solid-Core Technology

Wide pH Range

BEH C18

UPLC: 1.7 µm / UHPLC: 2.5 μm / HPLC: 3.5, 5, 10 µmO Si

O

O

Performance Benefits: General purpose column ideally suited for method development due to extreme pH stability and applicability to the broadest range of compound classes.

Bonding: Trifunctional C18, fully end-capped, bonded to Ethylene Bridged Hybrid (BEH) substrate.

BEH C8

UPLC: 1.7 µm / UHPLC: 2.5 μm / HPLC: 3.5, 5, 10 µmO Si

O

O

Performance Benefits: General purpose column ideally suited for method development due to extreme pH stability and applicability to the broadest range of compound classes.

Bonding: Trifunctional C8, fully end-capped, bonded to Ethylene Bridged Hybrid (BEH) substrate.

BEH Shield RP18UPLC: 1.7 µm / UHPLC: 2.5 μm / HPLC: 3.5, 5, 10 µm

O Si

CHPolar Group

3

CH 3

Performance Benefits: Alternate selectivity compared to straight chain C18, particularly with phenolic analytes. Compatible with 100% aqueous-phase composition.

Bonding: Monofunctional embedded polar C18, fully end-capped, bonded to Ethylene Bridged Hybrid (BEH) substrate.

BEH PhenylUPLC: 1.7 µm / UHPLC: 2.5 μm / HPLC: 3.5, 5 µm

O SiO

O

Performance Benefits: Excellent method development column for alternate selectivity, particularly in regard to polyaromatic compounds. Unique level of pH stability for a Phenyl bonded phase.

Bonding: Trifunctional C6 Phenyl, fully end-capped, bonded to Ethylene Bridged Hybrid (BEH) substrate.

BEH HILICUPLC: 1.7 µm / UHPLC: 2.5 μm / HPLC: 3.5, 5 µm

Performance Benefits: Excellent for retention of very polar, basic, water soluble analytes. Specifically designed and tested for HILIC separations using mobile phases containing high concentrations of organic solvent.

Bonding: Unbonded Ethylene Bridged Hybrid (BEH) substrate.

BEH AmideUPLC: 1.7 µm / UHPLC: 2.5 μm / HPLC: 3.5, 5 µm

O SiO O

O NH 2

Linker

Performance Benefits: Rugged HILIC stationary phase designed to separate a wide range of very polar compounds. Especially good at separating carbohydrates (saccharides) using high concentrations of organic modifier, elevated temperature, and high pH. Compatible with all modern detectors including MS, ELSD, UV, and fluorescence.

Bonding: Trifunctional amide bonded to Ethylene Bridged Hybrid (BEH) substrate.

C18+UPLC: 1.6 µm / UHPLC:: 2.7 μm

O SiO

O

Performance Benefits: General purpose reversed-phase column designed to maximize efficiency. A charged-surface-silica-solid-core particle enables excellent peak shape for basic compounds at low pH, especially in low concentration modifier mobile phases. Offers complementary selectivity to traditional C18 columns.

Bonding: Trifunctional C18 ligand, fully end-capped, bonded to a charged surface silica solid-core particle substrate.

C18

UPLC: 1.6 µm / UHPLC: 2.7 μmO Si

O

O

Performance Benefits: General purpose reversed-phase column designed to maximize efficiency. Balanced retention of acids, bases, and neutrals at low- and mid-range pH.

Bonding: Intermediate coverage trifunctional-C18 ligand, fully end-capped, bonded to a silica solid-core particle substrate.

T3UPLC: 1.6 µm / UHPLC: 2.7 μm

O SiO

O

Performance Benefits: Aqueous mobile-phase compatible column designed to maximize efficiency. Provides balanced retention for both polar and non-polar compounds.

Bonding: T3 (C18) bonding and endcapping, bonded to a silica solid-core particle substrate

C8

UPLC: 1.6 µm / UHPLC: 2.7 μmO Si

O

O

Performance Benefits: General purpose column designed to maximize efficiency. Similar selectivity, but shorter retentivity when compared to typical C18 phases.

Bonding: Trifunctional C8, fully end-capped, bonded to a silica solid-core particle substrate.

Shield RP18UPLC: 1.6 µm / UHPLC: 2.7 μm

O Si

CHPolar Group

3

CH 3

Performance Benefits: Excellent method development column designed to give maximum efficiency. Alternative selectivity when compared to typical C18 phases, especially phenolic compounds.

Bonding: Monofunctional embedded polar C18, fully end-capped, bonded to a silica solid-core particle substrate.

PhenylUPLC: 1.6 µm / UHPLC: 2.7 μm

O SiO

O

Performance Benefits: Excellent method development column designed to give maximum efficiency as well as alternate selectivity, particularly in regard to polyaromatic compounds.

Bonding: Trifunctional C6 Phenyl, fully end-capped, bonded to a silica solid-core particle substrate.

HILICUPLC: 1.6 µm / UHPLC: 2.7 μm

Performance Benefits: High efficiency column designed for retention of extremely polar, basic, water-soluble analytes.

Bonding: Unbonded high-purity silica solid-core particle substrate.

Wide Selectivity Range

High Efficiency

CSH C18

UPLC: 1.7 µm / UHPLC: 2.5 μm / HPLC: 3.5, 5, 10 μmO Si

O

O

Performance Benefits: General purpose reversed-phase column that offers excellent pH stability and rapid mobile-phase re-equilibration for method development. Charged Surface Hybrid (CSH™) Technology enables superior peak shape and increased loading capacity for basic compounds.

Bonding: Trifunctional C18 ligand, fully end-capped, bonded to a Charged Surface Hybrid (CSH) particle substrate.

CSH Phenyl-HexylUPLC: 1.7 µm / UHPLC: 2.5 μm / HPLC: 3.5, 5 µm

O SiO

O

Performance Benefits: General purpose alternative selectivity ligand that provides pi-pi interactions with polyaromatic compounds, while maintaining excellent reproducibility at pH extremes. Charged Surface Hybrid (CSH) Technology enables superior peak shape and increased loading capacity for basic compounds.

Bonding: Trifunctional C6 Phenyl ligand, fully end-capped, bonded to a CSH particle substrate.

CSH Fluoro-PhenylUPLC: 1.7 µm / UHPLC: 2.5 μm / HPLC: 3.5, 5 µm

O Si F

FF

FF

O

O

Performance Benefits: General purpose column that provides a very high degree of analyte selectivity, especially when using low-pH mobile phases. Charged Surface Hybrid (CSH) Technology enables superior peak shape and increased loading capacity for basic compounds.

Bonding: Trifunctional propyl fluorophenyl ligand, non-end-capped, bonded to a CSH particle substrate.

HSS C18

UPLC: 1.8 µm / UHPLC: 2.5 μm / HPLC: 3.5, 5 µmO Si

O

O

Performance Benefits: Ultra performance C18 chemistry, increased retention, superior peak shape, resists acid hydrolysis at low pH.

Bonding: High coverage trifunctional C18, fully end-capped, bonded to a High Strength Silica (HSS) particle substrate.

HSS C18 SBUPLC: 1.8 µm / UHPLC: 2.5 μm / HPLC: 3.5, 5 µm

O SiO

O

Performance Benefits: Unique, non-end-capped C18 chemistry designed specifically for method development scientists. Offers unique Selectivity for Bases (SB) when operating under low-pH conditions.

Bonding: Intermediate coverage trifunctionally bonded C18, no endcapping, bonded to High Strength Silica (HSS) particle substrate.

HSS T3UPLC: 1.8 µm / UHPLC: 2.5 μm / HPLC: 3.5, 5 µm

O SiO

O

Performance Benefits: Aqueous mobile-phase compatible column designed for exceptional polar compound retention.

Bonding: T3 (C18) bonding and endcapping, bonded to High Strength Silica (HSS) particle substrate.

HSS PFPUPLC: 1.8 µm / UHPLC: 2.5 μm / HPLC: 3.5, 5 µm

O Si F

FF

FF

O

O

Performance Benefits: A general purpose column designed to maximize selectivity differences for Lewis bases through pi-pi interactions. The rigid aromatic ring provides additional selectivity based on shape, dipole moment, and hydrogen bonding interactions.

Bonding: Trifunctional pentafluorophenyl ligand, non-end-capped, bonded to High Strength Silica (HSS) substrate.

HSS CNUPLC: 1.8 µm / UHPLC: 2.5 μm / HPLC: 3.5, 5 µm

O SiCN

Performance Benefits: A general purpose column that shows contrasting analyte selectivity when compared to C18 phases. This column can be used for both reversed-phase and normal-phase separations.

Bonding: Sterically hindered, mono-functional cyano-propyl ligand, non-end-capped, bonded to High Strength Silica (HSS) substrate.

The choice of stationary phase influences the selectivity of the separation. The bonded phases and particle substrates used in Waters® HPLC Columns are developed to maximize the differences in analyte retention to help resolve the most demanding separation challenges.

BEH C18

BEH Shield RP18

BEH Phenyl

HSS T3

HSS C18

HSS C18 SB

HSS CN

CSH Phenyl-Hexyl

CSH Fluoro-Phenyl

CSH C18

BEH C8

Conditions:Columns: 2.1 x 100 mm

Mobile phase: 72% water/28% methanol (v/v)

Flow rate: 0.5 mL/min

Injection vol.: 5.0 µL

Sample conc.: 10 µg/mL

Temperature: 50 °C

Detection: UV @ 254 nm

Sampling rate: 20 pts/sec

Time constant: 0.1 min

Instrument: ACQUITY UPLC® with PDA Detector

Compounds [EPA 8330 Standard Mixture):1. HMX

2. RDX

3. 1,3,5-Trinitrobenzene

4. 1,3-Dinitrobenzene

5. Nitrobenzene

6. Tetryl

7. 2,4,6-Trinitrotoluene

8. 2-Amino-4,6-Dinitrotoluene

9. 4-Amino-2,6-Dinitrotoluene

10. 2,4-Dinitrotoluene

11. 2,6-Dinitrotoluene

12. 2-Nitrotoluene

13. 4-Nitrotoluene

14. 3-Nitrotoluene

0 2 4 6 8 10 12 14 16 18 20 min

Comparative separations may not be representative of all applications.

CORTECS Phenyl

CORTECS C8

CORTECS C18

CORTECS C18+

HSS PFP

CORTECS UPLC T3

CORTECS UPLC Shield RP18

7,8

5,6

3 4,52 1 7

10,11,12,13,149,8 6

6,7 8,9

345678

9,10,1112 13 14

2,367 8

9,10,11

8,9,137 10116 1412

1 43 52 7 8 109 116 141312

87 109 116

4 35 8 710,119 6141312

1 4 5312,13 142

1 43 52

1 2

1 43 52

1

9,10,11125

2

1 43 62

1 43 52

1 43 72

14131210,11

14 5

12,13,14

13 14

12 13 146 7

108 9 11

108 9 11

12 13 14

1 2,3 4 5 7 9 6 11 10 12 8,13 14

1 2 347105 6111489, 13

12

1 23 4

7 105 8 96

11 12 13 14

1 2 3 45 6

7, 89 1110

12 13 14

1 2 3 45 6 9 1110

12 13 147 8

1 2 3 4

5 12 14 13 11 10 6

9 7,8

1 2 3 4

5 7 6 10 11 13

12,8, 9

14

Selectivity Choices Nitroaromatic Compounds

Extend Column Performance and Lifetime