3
IND560x Terminal The intrinsically safe IND560x weighing terminal brings uncompromising power and versatility into Division 1, Zone 1 and Zone 21 classified areas. Choose from analog or digital weighing technologies and communicate via serial, Ethernet and a variety of PLC interfaces. Easily program the feature-rich IND560x or create custom software applications. Whatever the need, the IND560x is the perfect solu- tion for hazardous area weighing. Weigh intuitively SmartTrac™ graphical display, operator prompting and one- touch access to terminal features through softkeys, work to improve productivity and minimize errors. Increase speed The IND560x features an ultra-fast A/D conversion rate. With TraxDSP™ tunable digital filtering to suppress environmental effects on weighing accuracy, enjoy precise, repeatable measurements from milligrams to tons. Connect easily Fast PLC integration and network access into the hazardous area available via the ACM500 communication module. Uncompromised weighing in hazardous areas Control process Internal discrete I/O options establish direct control of automatic and semi-automatic processes fully within hazardous areas. Zone 1/21, Division 1 Weighing Terminals IECEx

Weighing Terminals - PCN Europe · • Operation and function similar to IND560, reducing need for training when operating both safe and hazardous area applications • Over/Under

  • Upload
    dothu

  • View
    224

  • Download
    0

Embed Size (px)

Citation preview

IND560x TerminalThe intrinsically safe IND560x weighing terminal brings uncompromising power and versatility into Division 1, Zone 1 and Zone 21 classified areas. Choose from analog or digital weighing technologies and communicate via serial, Ethernet and a variety of PLC interfaces. Easily program the feature-rich IND560x or create custom software applications. Whatever the need, the IND560x is the perfect solu-tion for hazardous area weighing.

Weigh intuitivelySmartTrac™ graphical display, operator prompting and one-touch access to terminal features through softkeys, work to improve productivity and minimize errors.

Increase speedThe IND560x features an ultra-fast A/D conversion rate. With TraxDSP™ tunable digital filtering to suppress environmental effects on weighing accuracy, enjoy precise, repeatable measurements from milligrams to tons.

Connect easilyFast PLC integration and network access into the hazardous area available via the ACM500 communication module.

Uncompromised weighing in hazardous areas

Control processInternal discrete I/O options establish direct control of automatic and semi-automatic processes fully within hazardous areas.

Zone 1/21, Division 1

Wei

ghin

g Te

rmin

als

IECEx

Features and benefits

• Intrinsically safe design means no barriers or enclosures required when placing terminal in hazardous areas classified Zone 1, Zone 21 or Division 1

•Mobileweighingavailablewhenharsh/analogenclosuremodelisusedwiththeIND560x-PAB(PowerAdapterBoard)andavailable external NiMH battery pack

•TraxEMT™(EmbeddedMaintenanceTechnician)automaticallylogscriticalsysteminformationtoaidwithstringentprocessvalidationrequirementsandcompliancetoregulatorycontrols.Builtindiagnostictestsimproveserviceability

•ACM500safeareacommunicationmodulesupportsavarietyofPLCinterfacesalongwithEthernetandserialports,allowingfor easy integration of the IND560x into facility networks and broader control systems

•ReduceinstallationcostsbyutilizingtheACM200communicationmodulewhenonlyserialcommunicationtothesafeareaisrequired

•Communicationhardwareoptionsincludebothcurrentloopandfiberoptics.InterfacewithlegacyMETTLERTOLEDOdataconverters is ensured, providing a clean migration path from legacy equipment

•15programmablesoftkeyshelpeliminateoperationerrorsandincreaseproductivity•Easilyaccessedmemorytablesstoretargetandtarerecords,eliminatingtheneedforexternaldatastorageandimproving

process efficiency•Programmableon-screenpromptsguideoperatorsconsistentlythroughcomplexoperations,supportingfacilitySOPsand

improving overall process quality•OperationandfunctionsimilartoIND560,reducingneedfortrainingwhenoperatingbothsafeandhazardousarea

applications•Over/UndermodeofoperationisenhancedwithgraphicaldisplayandprogrammableI/Otoclearlyindicatetransactionstatus•MaterialTransfermodesupportslatchedtargetcontrolI/O,makingtheIND560xanexcellenthazardousareafillingordosing

controller•Optionalapplicationsoftwaremodulesaddenhancedfeatureswhenrequired:

IND560x terminal

−Fill-560:Advancedfillinganddosing −Drive-560:Simple(In/Out)vehicleweighing−COM-560:Supportforlegacycommunicationprotocols −TaskExpert™:Tocreatecustomapplications

Enclosure dimensions (H x W x D)

Panelmount:160x265x92mm(6.3x10.4x3.6in.)

Harshenvironment/desk/wall:170x289x183mm(6.7x11.4x7.2in.)

Enclosure construction/ environmental protection

Panelmount:Stainlesssteelfrontpanel,aluminumchassis.CertifiedIP65.Lowprofilefrontpanelreducescontamination Harshenvironment:Fullstainlesssteelhousing.CertifiedIP69k,IP68,IP65

Operating environment -10°Cto40°C(14°Fto104°F),10%to95%relativehumidity,non-condensing

Display 128x64dotmatrixLiquidCrystalDisplaywithbacklightstandard.21mmhighweightdisplay

Power WorkswithAPS768xintrinsicallysafepowersupply.120VACand240VACmodelsavailable.Harshenvironment/analogmodelcompatiblewithexternalNiMHbatterypack,whenoptionalIND560x-PowerAdapterBoard(PAB)isinstalled

Keypad Power on/off. Clear, Tare, Print, Zero. Numeric keys. Navigation keyset. 5 softkeys

Scale types Supportssinglescaleinterface:Analogscale,5VDCexcitation,upto4x350Wloadcells(87Ωminimumresistance),2or3mV/V, 100,000d maximum resolutionIDNetscale,currenthigh-precisionTBrick-Exbases

Calibration Separatesingle-stepZeroandSpan,available5-pointlinearityadjustment,stepcalibrationorCalFREE™(notestweightsneeded).Program and save a 25-step calibration test sequence for guaranteed repeatability. Configurable calibration expiration and email alerts available

Update Rates A/D conversion ≤366Hz.Targetupto50Hz.PLCupto20Hz.DiscreteI/Oupto25Hz

Serial connectivity Standard:OnestandardintrinsicallysafeRS-232port(COM1).OptionalCOM4/COM5:Bi-directional,dual-channelfiberopticorintrinsicallysafecurrentloopinterfaceforcommunicationtosafearea

Peripheral communication devices

Fiber optic or current loop connection to ACM500 in safe area; Current loop connection to ACM200 in safe area; Fiber optic connection to legacy METTLERTOLEDOfiberopticconverterCan operate as a remote display for other terminals in Ex or safe area

Supported communication*

Serial(RS-232/422/485),Ethernet10Base-T,PLC(A-BRIO,AnalogOutput,DeviceNet,PROFIBUSDP,EtherNet/IP,ModbusTCP)Inputs:ASCIII,CPTZ,SICSLevel0/1,RemotedisplayOutputs:METTLERTOLEDOContinuous,Demand,Continuoustemplate,5configurabletemplates* Some communication options only available with ACM500

I/O InternalsolidstatediscreteI/Ooptionsofferatotalof4inputsand6outputs.Choosefromoneofthreeoptions:ActiveInputs/ActiveOutputs, Active Inputs/Passive Outputs, Passive Inputs/Passive Outputs - Active Inputs are powered internally by the IND560x and are designed for use with simple hazardous area switches - Active Outputs are powered internally by the IND560x and provide 12 VDC switching at 50 mA total. These are intended for use with low-power, intrinsically safe solenoids - Passive Inputs and Passive Outputs require power to be provided externally through an appropriate barrier. Entity parameters must be confirmedTotalI/Ocontrolexpandableto12inputsand18outputsusingARM100modulesandRS-485fromtheACM500

Ex approvals US:IS,ClassI,II,III;Div1;GroupsA-GT4Ta=-10°Cto+40°C; IP65;Type4I/1/AExibIICT4

Controldrawing72191600Canada: IS,ClassI,II,III;Div1;GroupsA-GT4Ta=-10°C to +40°C;IP65;Controldrawing72191600

ATEX:CertificateBVS09ATEXE010and first supplementII2GExib[opisGa]IICT4GbII2DExib[opisDa]IICT60°C Db IP65

IECExCertificateIECExBVS10.0096XExib[opisGa]IICT4GbExib[opisDa]IIICT60°CDb IP65

Weights and measures approvals

USA: ClassII,100,000d;ClassIII/IIIL,10,000d;CoC#05-0572A4Canada: ClassII,100,000d;ClassIII,10,000d;ClassIIIHD,20,000d;AM-5593Rev3Europe: ClassII,resolutiondeterminedbyplatformapproval;ClassIII,10,000e;TC6812Rev9MID:Catchweighing−T10230;GravimetricFilling−T10231

www.mt.com/IND560xfor more information

Subject to technical changes©08/2011Mettler-ToledoGmbHINDB0073.6E(A4)

METTLERTOLEDOisuniquelyqualifiedtoprovidetheinstallation,calibra-tion and maintenance services essential to ensuring accuracy, optimizing uptime and prolonging equipment life. Our service representatives will be there at the right time, with the right parts, the right tools and the right skills to meet your needs.

Essential Servicesfor Dependable Performance

METTLER TOLEDOService

Technical Specifications

Mettler-Toledo (Schweiz) GmbHIm Langacher8606GreifenseeTel.+41-1-944-22-11Fax.+41-1-944-31-70