1
DESCRIPTION Complete HET system with exposed manual Royal ® dual flush Flushometer and HET vitreous china dual flush floor mount fixture. Flush Cycle Model WETS-2002.1002-1.6 /1.1 WES (Down 1.6 gpf/6.0 Lpf, Up 1.1 gpf/4.2 Lpf) Code: 20021002 This space for Architect/Engineer approval Job Name Date Model Specified Quantity Variations Specified Customer/Wholesaler Contractor Architect The information contained in this document is subject to change without notice. Sloan Valve Company 10500 Seymour Avenue Franklin Park, IL 60131 Phone: 1-800-9-VALVE-9 (982-5839) or 1-847-671-4300 Fax: 1-800-447-8329 or 1-847-671-4380 www.sloanvalve.com Copyright © 2014 Sloan Valve Company WETS-2002.1002 04-14 26 1 / 2(673 mm) 10” or 12” (254 mm or 305 mm) 15” (381 mm) 26.75” (679 mm) 3 1 / 4” or 5 1 / 4(82 mm or 133 mm) 3 1 / 4” or 5 1 / 4(82 mm or 133 mm) 29 1 / 2” or 31 1 / 2(749 mm or 800 mm) CENTERLINE OF WASTE FIN. FLOOR FIN. WALL 4 3/4” (121 mm) 1 1/2” (38 mm) 11 1/2” (292 mm) 1” I.P.S. SUPPLY (DN 25 mm) C/L OF SUPPLY SPECIFICATIONS Quiet, exposed, diaphragm type, chrome plated dual flush HET Flushometer and vitreous china dual flush HET floor mount fixture with the following features: Flushometer Lifting Handle UP initiates reduced flush (1.1 gpf/ 4.2 Lpf), eliminating liquid and paper waste, saving a ½- gallon of water Pushing Handle DOWN initiates full flush (1.6 gpf/ 6.0 Lpf), eliminating solid waste and paper Reduces water volume by up to 30% when activated UPWARDS Antimicrobial Coating on Handle protects against germs Distinctive Green ADA Compliant Metal Non-Hold- Open Handle with Triple Seal Handle Packing signifies Water Conserving Device PERMEX ® Synthetic Rubber Diaphragm with Dual Filtered Fixed Bypass 1” I.P.S. Screwdriver Bak-Chek ® Angle Stop High Back Pressure Vacuum Breaker Flush Connection with One-piece Bottom Hex Coupling Nut Sweat Solder Adapter w/Cover Tube and Cast Wall Flange with Set Screw High copper, low zinc brass castings for dezincification resistance Diaphragm, Handle Packing, Stop Seat and Vacuum Breaker molded from PERMEX ® rubber compound for chloramine resistance Includes (2) adhesive backed Metal Wall Plates etched w/Instructions Valve Body, Cover, Tailpiece and Control Stop shall be in conformance with ASTM Alloy Classification for Semi-Red Brass. Valve shall be in compliance to the applicable sections of ASSE 1037. Fixture Vitreous china with Integral flushing rim Floor mounted elongated bowl 1 /2” I.P.S. top spud inlet 2 /8” trapway diameter Siphon jet flush Closet bolts and caps included 100% factory flush tested Toilet seat not included Recommended seats: Bemis - 1955CT/1955SSCT & 2155CT/2155SSCT Church - 295CT/295SSCT & 2155CT/2155SSCT Water closet shall be in compliance to the applicable sections of ASME A112.19.2/CSA B45.1 • Compliant with Buy American Act when purchased as a combination Model WETS-2002.1002 1.6/1.1 WES DF Manual HET Dual Flush Flushometer and HET Dual Flush Water Closet Efficiency Series B u y A m e r i c a n A c t C o m p l i a n t NOTE : Plumbing System Requirements • Minimum Flowing Pressure: 25 PSI • Minimum Flow Rate: 18 GPM • Maximum Static Pressure: 80 PSI NOTE: All vitreous china dimensions shown in these drawings are nominal. Dimensions can vary within the tolerances established in the governing ASME A112.19.2/CSA B45.1 standard. Please take this into consideration when planning rough-in and plumbing layouts.

WETS-2002.1002_10-13

Embed Size (px)

DESCRIPTION

FLUSH VALVE

Citation preview

DESCRIPTION

Complete HET system with exposed manual Royal® dualflush Flushometer and HET vitreous china dual flush floor mount fixture.

Flush Cycle

Model WETS-2002.1002-1.6 /1.1 WES (Down 1.6 gpf/6.0 Lpf, Up 1.1 gpf/4.2 Lpf)

Code: 20021002

This space for Architect/Engineer approval

Job Name Date

Model Specified Quantity

Variations Specified

Customer/Wholesaler

Contractor

Architect

The information contained in this document is subject to change without notice.

Sloan Valve Company10500 Seymour AvenueFranklin Park, IL 60131Phone: 1-800-9-VALVE-9 (982-5839) or 1-847-671-4300Fax: 1-800-447-8329 or 1-847-671-4380www.sloanvalve.com

Copyright © 2014 Sloan Valve Company WETS-2002.1002 04-14

26 1/2”(673 mm)

10” or 12”(254 mm or 305 mm)

15”(381 mm)

26.75” (679 mm)

3 1/4” or 5 1/4”(82 mm or 133 mm)

3 1/4” or 5 1/4”(82 mm or 133 mm)

29 1/2” or 311/2” (749 mm or 800 mm)

CENTERLINE OF WASTE

FIN.FLOOR

FIN.WALL

4 3/4”(121 mm)

1 1/2”(38 mm)

11 1/2”(292 mm)

1” I.P.S. SUPPLY(DN 25 mm)

C/L OFSUPPLY

SPECIFICATIONS

Quiet, exposed, diaphragm type, chrome plated dualflush HET Flushometer and vitreous china dual flush HETfloor mount fixture with the following features:

Flushometer• Lifting Handle UP initiates reduced flush (1.1 gpf/ 4.2

Lpf), eliminating liquid and paper waste, saving a ½-gallon of water

• Pushing Handle DOWN initiates full flush (1.6 gpf/ 6.0Lpf), eliminating solid waste and paper

• Reduces water volume by up to 30% when activatedUPWARDS

• Antimicrobial Coating on Handle protects againstgerms

• Distinctive Green ADA Compliant Metal Non-Hold-Open Handle with Triple Seal Handle Packing signifiesWater Conserving Device

• PERMEX® Synthetic Rubber Diaphragm with Dual Filtered Fixed Bypass

• 1” I.P.S. Screwdriver Bak-Chek® Angle Stop• High Back Pressure Vacuum Breaker Flush

Connection with One-piece Bottom Hex Coupling Nut

• Sweat Solder Adapter w/Cover Tube and Cast WallFlange with Set Screw

• High copper, low zinc brass castings fordezincification resistance

• Diaphragm, Handle Packing, Stop Seat and VacuumBreaker molded from PERMEX® rubber compound forchloramine resistance

• Includes (2) adhesive backed Metal Wall Plates etchedw/Instructions

• Valve Body, Cover, Tailpiece and Control Stop shall bein conformance with ASTM Alloy Classification for Semi-Red Brass. Valve shall be in compliance to the applicable sections of ASSE 1037.

Fixture

• Vitreous china with Integral flushing rim• Floor mounted elongated bowl• 1 1/2” I.P.S. top spud inlet • 2 1⁄8” trapway diameter• Siphon jet flush• Closet bolts and caps included• 100% factory flush tested• Toilet seat not included

Recommended seats:Bemis - 1955CT/1955SSCT & 2155CT/2155SSCTChurch - 295CT/295SSCT & 2155CT/2155SSCT

• Water closet shall be in compliance to the applicablesections of ASME A112.19.2/CSA B45.1

• Compliant with Buy American Act when purchased as a combination

Model

WETS-2002.1002 1.6/1.1 WES DFManual HET Dual Flush Flushometer and HET Dual Flush Water Closet

Efficiency Series Buy

American

Act

••C

ompliant

Buy

American

Act •

•C

ompliant

NOTE: Plumbing System Requirements• Minimum Flowing Pressure: 25 PSI• Minimum Flow Rate: 18 GPM• Maximum Static Pressure: 80 PSI

NOTE: All vitreous china dimensions shown in thesedrawings are nominal. Dimensions can vary within thetolerances established in the governing ASMEA112.19.2/CSA B45.1 standard. Please take this intoconsideration when planning rough-in and plumbing layouts.