Manufacturing/Fabrication Telecommunications Center Remote Site (Europe) Remote Site (Asia)
Scenario-CompatibleRPM’s Scenario softwarelets you build a centralmulti-user database withall the power measure-ments made by everypower monitor on yournetwork. You can getimmediate access toreal-time data such aswaveform oscilloscopesand power meters toshow you precisely whatis happening on yoursystem now. Events areplotted against powertolerance curves such asCBEMA or the newerITIC curve. Unlike othersoftware, Scenarioprovides you with plots of any chosen parameter from multiplemonitoring sessions on one graph, for a comprehensive pictureof your power system.
Full disclosure technology is crucial to predictivemaintenance. Starting with benchmark measurements of powerconditions, you can then build a power quality index(PQI) and follow it over time to spot anydeterioration. Scenario provides the toolsto compare the PQI against any otherparameter, allowing you to isolateproblems and take decisive action.
Flexible CommunicationsThe InSite Power Recorder comes standardwith an Ethernet RJ45 port and can beconfigured for TCP/IP communications. Youcan connect to InSite monitors over Ethernetnetworks, intranets, or even the Internet. You canalso connect to InSite monitors by dial-up phonelines using Reliable’s new, low-cost Ethernet Modem RouterModel 2140. Up to 253 Power Recorders in a network can beconnected on a single phone line, giving you access to 759
feeders (or voltage andcurrent pairs). UsingRPM’s communicationssoftware and anycombination of RPMPower Recorders(portable or stationary),you can create anetwork of dial-up anddirect connect monitor-ing locations for yourmonitoring system.
Future ExpandabilityThe InSite recorderhas two paths forfuture expansion andenhanced capabilities.The PRLink™ port is ahigh-speed communica-
tions link that offers communications to other devices at speedsof 200 megabits per second. This port can be used, forexample, to connect to a new analog/digital I/O module RPMhas in development to allow monitoring of analog quantitieswith transducers that supply a 4-20 ma output, as well asdigital on/off/I/O states from contact closure, breakers, or other
switches. The PRLink port and the option port will acceptother hardware options in development.
Time SynchronizationGPS time synchronization accuracy betweenmultiple InSite Power Recorders is achieved by
using NTP protocol through the Ethernetport, and ensures all InSite recorderson a network are in sync.(Check for availability.)
We’ve got the best technology to fityour power monitoring needs
HandheldFor quick checks and
spot readings on voltage,current and harmonics—
Reliable 43R.
Hi Speed MultipointPower Recorder™
For permanent monitoringof power quality at mission
critical data centers.
Power Recorder™
The world’s mostpopular portable power
monitor analyzes allaspects of power.
ScenarioOur powerful software that works on all RPM instruments.It performs predictive analysis, manages data, and givesadvance warning to avoid shutdowns.©
1998
Relia
ble
Pow
erM
eter
s.A
llrig
hts
rese
rved
.
Reliable Power Meters400 Blossom Hill RoadLos Gatos, CA 95032408-358-5100Fax 408-358-4420www.reliablemeters.com
Scenario™
Version 1.21Beta Release
Scenario works on all!
Up to 253 InSite Power Recorders can be networked on a single phone line giving you access to 759 feeders.
Reliable’s exclusive Report Writer produceswell formatted, easy-to-read reports.It sorts and manages all data collected bythe InSite. It can report on one, several,or all aspects of power and can becustomized to fit your reporting style.
Specifications Models 901/902
Connections
4 voltage channels, range 0 – 707 Volts RMS, supports all commonpower configurations (single, split-phase, wye and delta)
5 current channels, range 0 – 20 Amps RMS, built-in current transformers(for external CTs specify Option 905)
Measurements
True RMS voltage, true RMS current, RMS sags/swells, transients to130µs, 1000 Volts pk (Model 901), transients to 25µs, 6000 Volts pk(Model 902), frequency 45 – 65 Hz (± 0.1 Hz), harmonics to 63rdharmonic (magnitude, phase angle, THD), flicker to IEC 868 (Pst and Plt),watts, VA, VAR, PF (true and displacement), kW demand, kWh. Real-timeoscilloscopes for waveforms, harmonic spectra, phasor diagrams, powermeters, imbalance, impedance (source/load).
Sampling Model 901Phase-locked over fundamental frequency range 45 – 65 Hz,128 samples per cycle (6400 samples/sec @ 50 Hz, – 7680 samples/sec@ 60 Hz, each channel)
Sampling Model 902 (available 3rd qtr. 2000)Phase-locked over fundamental frequency range 45 – 65 Hz,640 samples per cycle (32,000 samples/sec @ 50 Hz, – 38,400samples/sec @ 60 Hz, each channel)
Semiconductor Technology
DSP: 32 bit floating point digital signal processor
Analog-to-digital converter: 20 bit, resolution 0.001 Volts
Memory: solid state memory for storage of up to 12,000 events(two sessions each 6,000 events)
Event Capture
Four independent channels, all-channel capture, Full Disclosuremethod (no thresholds or triggers to program), automatic time-base forbest presentation of event for any event length with 25% pre- andpost-trigger, events automatically plotted by history or against tolerancecurves (CBEMA, ITIC, or user defined).
Accuracy
± 0.3% rdg, ± 0.2% FS at 0 – 100% FS
Instrument Power
85 – 264 VAC or DC, 50/60 Hz, built-in auto-charging NiMH battery
UPS with 5 minutes backup, 13 VA consumption nominal (20 VA wheninternal UPS is charging)
Physical
Rugged, die-cast enclosure
Dimensions: 10.25" x 8.7 " x 3.4" (26cm x 22cm x 8.7cm)
Operating temperature: 0° to 50° C, 0 – 95% RH, non-condensing
Weight: 7.5 lbs. (3.4kg)
Communications Connections
RJ45 Ethernet port for connection to 10-base T (UTP), TCP/IP supportedRPM PRLink for future expansion, serial port
Optional modem available (Model 2140)
400 Blossom Hill Road, Los Gatos, CA 95032-4511408 358 5100 Fax: 408 358 4420e-mail: [email protected]
www.reliablemeters.com
RPM can also supplyexternal CTs from1 amp to 5000 amps,split-core, clamp-on,or flexible types.
InSite Power Recorder
Representative:
The Reliable Familyof Power MonitorsReliable offers a complete rangeof power monitoring instrumentsand supporting software for any
monitoring need; forhand-held, portable, orpermanently installedapplications. All our
instruments, includingthe InSite Power Recorder,
work with Scenario softwareto manage, visualize, and
compare data from differentsurveys and multiple monitors,and provide predictive
maintenance analysis.
Reliable Power Meters, Full Disclosure, PR/Link, Scenario, Multipoint Power Recorder,InSite Power Recorder, and Power Recorder are trademarks of Reliable Power Meters.Specifications are subject to change without notice.
Energy Manager/Power Quality ExpertPredicts Future Problems
Will Work Anywhere24X7
The InSite Power Recorder
Utility Substation Switchgear UPS/Generator Output Data Center
Introducing the New InSite Power Recorder System.
The Ultimate in Power Monitoring at a Very Economical Price.
What is InSite?The InSite Power Recorder™ is the most advanced instrumentof its kind. It can be installed at any permanent location whereall aspects of power need to be monitored. You can use it insubstations; switchgear; for monitoring incoming and internalpower at data centers, factories, or commercial buildings.
What Does it Measure?The InSite simultaneously measures power quality, energy,power consumption, harmonics, and flicker. PC softwaredisplays real-time meters andoscilloscopes.
Power Quality: Sags, swells, wave-shape deviations, transients, interruptions, frequency, imbalance.
Power Consumption and Power Flow: Energy, demand, watts, VA, VAR, PF, and kWh.
Harmonics and Flicker: Harmonics measurement to 63rd harmonic, THD, flicker to IEC 868.
Harmonics Tracking: Summaries of all 63 individual harmonics over time, voltage, and current.
Real-time Meters and Oscilloscopes: Voltage, current, power, waveforms, harmonic spectrum, flicker, and impedance.
Why is it Unique?The InSite utilizes Full Disclosure™ technology, and—like otherReliable portable and fixed monitors—provides predictivemaintenance analysis.
Full Disclosure: The InSite comprehensively captures all power information, without requiring pre-set thresholds or triggers. Everything you want to know is measured and analyzed on all channels.
Predictive Analysis: Scenario™ Predictive Maintenance software reveals potential power problems before they happen. It answers such crucial questions as:• Is my power getting better or worse?• Where in my system is my power better or worse?• Why is my power getting worse?
Armed with this information, youare able to take corrective action and avoid costly disruptions.
Easy to InstallThe InSite monitor is housed in asmall (10.25" x 8.7") rugged enclosure,and weighs only 7.5 pounds. Itcomes with easily accessible terminalstrips for voltage and currentconnections, and has built-in currenttransformers for monitoring currentmetering circuits found in substationsand switchgear (external CT optionalso available).
Easy to UseAn InSite monitor is up and running in minutes. There are nocomplicated menus or programming steps, no thresholds ortriggers to set, and there’s no need to manage memory and turnone type of measurement off to enable another. It’s a true multi-tasking and multi-functioning monitor. RPM’s intuitive, Windows-based software will provide you with a summary report, eventgraph or meter value with a couple of clicks of your mouse.
Set up a network of any number of InSite Recorders via LAN/WAN or dial-up connection.
Mount in switchgear or NEMA cabinets.
Finding power disturbance events by severity or time is simple.The InSite Power Recorder automatically presents eventsagainst power tolerance curves that plot events by severity, orby a history summary showing time of occurrence. Events canbe plotted against industry standard curves such as CBEMA,ANSI, or ITIC, or you can create your own curve for yoursituation with RPM’s unique curve editor. Curves can be edited,reshaped, and superimposed on event data any time, evenafter monitoring. The InSite Power Recorder is the only monitorthat can catch any event of any length. It behaves like an
Historical summary of events Captured waveshape event (transient)
RMS sag and swell event plot
Real-time harmonic spectrum Harmonic phase anglesand magnitudes
Individual harmonic summary
THD: total harmonic distortion (V or I)
Fundamental frequency summary Flicker (IEC 868) with Pst, Plt
Events plotted against CBEMA curve
Events plotted against ITIC curve RMS summary (V or I)
Monitor Distortion, Track Harmonics and Flicker
Assure Power Quality, Capture All Disturbance Eventsautomatic fault recorder by automatically adjusting time-basesto give the best presentation of waveshapes, sags, swells, andtransients with pre- and post-trigger information. The InSitePower Recorder makes it easy to identify the origin of sags andswells by simultaneously capturing both voltage and currentinformation and plotting them together. The high samplingrate of the Model 901 InSite Power Recorder enables it tocatch transients down to 130 µs in duration, and is ideal forcapturing power factor correction capacitor and otherswitching events originating on distribution systems.
63 harmonics and THD are measured on every cycle on all channels.You can view the complete spectrum or any individual harmonics' history.
Red LED indicates presence of excessiveground current
Infrared Port
Terminal blocks allow easy voltageand current connections
LEDs indicate power on, Ethernet statusPR Link
Serial
Ethernet
Green LEDs indicategood connection tovoltage and current EthernetPower
PR/Link PR/Link PR/Link Ethernet
Activity
!
Voltage Connections
Phase A volts
Phase B volts
Phase C volts
Neutral (not used on delta systems)
Ground
Instrument power, live
Neutral
Ground
The InSite has 5 voltage channelssuitable for single phase, split-phase,wye or delta systems.
Safe and easy to install:Hinged covers allow easy access to terminals.After wiring is complete, secure covers withjust 2 screws. Now your InSite installation is
complete, fingerproof, and safe.
Option Port
Serial Option Port
ACTUAL SIZE OF INSITEPOWER RECORDER
Current Connections
Phase A
Phase A
Phase B
Phase B
Phase C
Phase C
Neutral
Neutral
Ground
Ground
Demand and kWh VAR Imbalance (V or I)
Oscilloscopes Phasor diagram and impedance vectors
Real-time meters and power cube
Watts VA Power Factor (true and displacement)
View Power Conditions in Real-time
Manage Power Consumption and Energy CostsThe InSite Power Recorder measures watts, VA, VAR, andpower factor (true and displacement) on a cycle by cyclebasis. It provides summaries showing minimum, maximum, andaverage values for each phase as well as totals of all phases.Graphic reports can be pasted into a word processor, and thedata can be easily exported to spreadsheets. For energy use,any demand period from 5 minutes to one hour can be
selected for plotting demand profiles, with or without a slidingwindow. PC software displays real-time meter screens showingfundamental as well as true power quantities (i.e., includingharmonics) and accumulates kWh. A power cube plots active,reactive, and harmonic power to provide a quick visual displayof the extent of harmonic distortion.
The InSite Power Recorder offers the most advanced toolsto view any aspect of power in real-time. For example, youcan obtain oscilloscope traces of any voltage or currentchannel, plot an individual waveform, or all of them together.Add and subtract tools allow you to compare calculatedwaveforms with measured ones to identify ground loops orleakage currents. Monitoring connections can be verified
with a phasor diagram screen. You can even change anyconnection or current transformer polarity from the safetyof your PC using software buttons. Other screens displayharmonic spectra, flicker components, load and sourceimpedance. You can view any real-time screen at any time,even when the InSite Power Recorder is recording disturbanceevents and monitoring consumption.