E V O LV I N G A C T I V E C O M P O N E N T M E A S U R E M E N T S O L U T I O N S
▪ New DDS (direct digital synthesizers) source
improving:
• phase noise by 30 dB
• measurement performance of apps: SMC+phase, differential-IQ, modulation distortion, NVNA, iTMSA, IMD
• dynamic range in sub-THz bands by 30 dB
▪ High-performance analog-SigGen-class low phase
noise (Option UNY, Enhanced low-phase noise)
▪ 3rd RF source up to 13.5 GHz on 4-port PNA-X
High-
performance
analog
SigGen
class phase
noise
Optional
3rd RF
Source
What’s NEW
2
G E T T H E R E S O L U T I O N Y O U N E E D
New DDS Source
High-performance analog-
signal-generator grade phase
noise helps you to save your
test time and simplify your
test configuration.
More sources
The third RF source on 4-
port PNA-X simplifies
measurement configuration
for complex measurements
and save bench footprint.
Applications
Modulation distortion
application helps you to
measure EVM/NPR of
amplifiers, mixers and
frequency converters.
3
C H A L L E N G E S M E T – N O N E E D F O R H I G H - P E R F O R M A N C E S I G G E N
New PNA/PNA-X Option UNY
PSG
PSG–UNY- mode 1
Current PNA/-X
Export control limit
• Eliminates the need for external
high-performance analog signal
generators for the use of LO or
where low-phase noise is needed.
4
C H A L L E N G E S M E T - M O R E T H A N 5 0 T I M E S FA S T E R !
Current PNA Enhanced PNA with new DDS synthesizers
Frequency: 20 GHz, Span: 2 GHz, IFBW: 10 kHz
SMC+Phase measurement - Data deviation from linear phase
4.5 seconds with averaging 0.1 seconds with no averaging
Today’s instruments test quickly but increase uncertainty, now you can measure faster
without sacrificing accuracy
To get the same stable phase measurement, it takes
5
• Reliable, repeatable measurements at
higher frequencies with 30 dB more
dynamic range in sub-THz measurements (using the new PNA, the N5292A test set, and
frequency extenders)
B E T T E R P E R F O R M A N C E I N T H Z
Dynamic range improvement
from 750 GHz to 1.1 THz
6
• Complex measurements require
multiple instruments, but the 3rd source
eliminates the need for an external
signal generator for mixer IMD
measurements
• Three high-performance analog signal
generators
• Can be used as an independent signal
generator.
C H A L L E N G E S M E T – S Y S T E M S I M P L I F I C AT I O N
Note: The 3rd source is available only with 4-port PNA-X.
3rd Source
IMD
OutputIMD
Input
7
C H A L L E N G E S M E T - P E R F O R M A W I D E VA R I E T Y O F T E S T S
• Gain compression
• SMC+Phase
• Modulation distortion
• Differential I/Q
• IMD
• SA and NPR
• Noise figure
• Nonlinear Vector Network Analysis (NVNA) /X-
parameters
• PLTS
• Real-time S-parameter and power uncertainty
• Source-phase control for active-load pull
• Active-hot parameters
• and more…
DDS improves the measurement performance of applications where the phase measurement stability is critical.
Stable phase measurement
with enhanced PNA
8
Best solution for amplifier characterization!
S I M P L I F I E S Y O U R A M P L I F I E R T E S T
EVM, NPR and ACPR measurements
under modulated stimulus conditions
without doing demodulation
• Lowest residual EVM and NPR
• Faster measurements than SA
• Better accuracy and
reproducibility
• Simple and intuitive
• System simplification
• No analysis bandwidth restriction
Launched in June 2019
mmW
frequency
Extremely
Wide
Modulation
BW
Instrument
cost
New
challenges
Evolving
Standards
Challenging
EVM
Requirements
Calibration
and
Accurate
Power
9
C H A L L E N G E S M E T - M O R E T H A N J U S T A M P L I F I E R S
PNA-X
VSG
• New target DUTs: Mixer and frequency converters (with embedded-LO) for A&D and 5G
• Same features/advantages as amplifier measurements
• Satisfies increasing demand for testing converters with wideband, modulated-carrier signals
DUTRequired
applications
Amplifier S93070xB
Frequency converterS93070xB +
S93083B
Frequency converter
with embedded-LO
S93070xB +
S93083B
+ S93084B
10
• See the new capabilities in the demo video.
• Frequency Converter Group Delay Measurement
• Frequency Converter Two-Tone IMD Measurement
• Phase Noise Comparison with MXG Signal Generator
• Comparison with Current PNA-X Source
https://www.youtube.com/watch?v=kMvyOZhMLfc&t=3shttps://www.youtube.com/watch?v=kMvyOZhMLfc&t=153shttps://www.youtube.com/watch?v=kMvyOZhMLfc&t=389shttps://www.youtube.com/watch?v=kMvyOZhMLfc&t=448s
11
All PNA/PNA-X base models will have the new source.
• N5221B/22B/41B/42B/49B-UNY Enhanced low phase noise (export-controlled)
• N5224B/25B/27B/44B/45B/47B-UNY Enhanced low phase noise (export-controlled)
• N5249B-XSB 3rd RF source up to 8.5 GHz
• N5241B/2B/4B/5B/7B-XSB 3rd RF source up to 13.5 GHz
Note: Option XSB is available only with N524xB PNA-X option 422 or 423
• Upgrade kits are available for the current PNA/PNA-X.
12
• Signal source upgrade for the current PNA/PNA-X B models
• N52xxBU-2S7 for all single-source 2-port PNA/PNA-Xs:
$13,900 + 1.5 hours installation labor at service center [total about $15k]
• N52xxBU-4S7 for all 4-port PNA/PNA-Xs and dual-source 2-port PNA-X:
$21,900 + 1.5 hours installation labor at service center [total about $23k]
• Upgrade work: It can be done at the local service center
• When you upgrade PNA/PNA-X A models, you also need to upgrade the unit
to the B model. http://na.support.keysight.com/pna/b-upgrade.html (N8989A-SR6 synthesizers are not needed even in the case that those are needed, because the new signal
sources will be added with this source upgrade.)
http://na.support.keysight.com/pna/b-upgrade.html
13
• For PNA/PNA-Xs that are already equipped with the new source
• N524xBU-XSB: option XSB retrofit
• N52xxBU-UNY: option UNY retrofit
• 2-port to 4-port upgrade
• N522xBU-660 (option 200 to 400 upgrade)
• N52xxBU-661 (option 201 to 401 upgrade)
• N522xBU-665 (option 205 to 405 upgrade)
• N52xxBU-677 (option 217 to 417 upgrade)
• N52xxBU-679 (option 219 to 419 upgrade)
• N522xBU-680 (option 220 to 420 upgrade)
• N524xBU-284 (option 217 to 222 or 219 to 224 upgrade)