4
Which is most accurate method of load ow analysis? Kamalesh SaraswatSystem Design Engineer-Electrical Like (4) Comment (9) Share Follow Reply Privately 6 months ago Comments Nazim ha!ar" P#C" R#" $r% Larry &oo's" Ph$" (L N) pen Networker* +,+9- an' + others like this 9 .omments /0mp to most re.ent .omment karikalan karikalan Muthukrishnan H DC Com!etency Centre" #lstom $rid Newton1Raphson sol0tion metho' o Like o Reply privately o Flag as inappropriate o 6 months ago 2ipin %i!in &andey Manager #!!lication Engineering' %D at &ower (esearch and De)elo!ment Consultants &)t *td yes NR is more a..0rate than any other 30t now its also ol' 3e.a0se i we r0n this metho' on p0re 'istri30tion system than we have to apply some .orre.tion a.tor "i we applying this metho' with m0lti terminal 5 $C system than we have to p0t some another .orre.tiom a.tor 30t yes NR S most a..0rate with 3asi.% o Like o Reply privately o Flag as inappropriate o 6 months ago PR7$##P &(#DEE& S#$#(

Which is Most Accurate Method of Load Flow Analysis

Embed Size (px)

DESCRIPTION

load

Citation preview

Which is most accurate method of load flow analysis?Kamalesh SaraswatSystem Design Engineer-Electrical Like (4) Comment (9) Share Follow Reply Privately 6 months agoCommentsNazim Ghaffar, PEC, RE,Dr. Larry Woods, PhD, (LION) Open Networker: 2829+and2 otherslike this9 commentsJump to most recent comment karikalankarikalan MuthukrishnanHVDC Competency Centre, Alstom GridNewtonRaphson solution method Like Reply privately Flag as inappropriate 6 months ago BipinBipin PandeyManager Application Engineering& BD at Power Research and Development Consultants Pvt Ltdyes NR is more accurate than any other but now its also old because if we run this method on pure distribution system than we have to apply some correction factor ,if we applying this method with multi terminal HVDC system than we have to put some another correctiom factor but yes NR IS most accurate with basic. Like Reply privately Flag as inappropriate 6 months ago PRADEEPPRADEEP SAGARELECTRICAL DESIGNWhat about accelerated NR load flow? It is with correction factor Like Reply privately Flag as inappropriate 3 months ago JOHN KWEKUJOHN KWEKU AMOO-OTOO, Phd(2012),P.ECONSULTANT-TECHNICAL SOLUTIONS AND EQUIPMENT RELIABILITY-POWER SYSTEMS at Saudi AramcoThere are various load flow analysis Algorithms like Gauss Seidel, Newton Raphson, etc. But the most accurate one is Newton Raphson. Like Reply privately Flag as inappropriate 3 months ago AdiAdi SofaSr. Electrical Engineernewthon rapson fast in speed, but high requirement in initial value, but for radial system with long lines, its better use fast decoupled. Like Reply privately Flag as inappropriate 3 months ago AlejandroAlejandro Navalpotro FelipeElectrical Engineer - UPMI think it's the NewtonRaphson method. I usually use it. Like Reply privately Flag as inappropriate 1 month ago balajibalaji balajiElectrical Engineer at ABB India LimitedFast Decoupled Method is the fastest Method of Load flow analysis .The order of Priority is Fast Decoupled, Newton raphson and Gauss seidel method Like Reply privately Flag as inappropriate 17 days ago IftikharIftikhar AhmedSenior Engineer at Pakistan Nuclear Regulatory AuthorityNewton Raphson Like Reply privately Flag as inappropriate 15 days ago JithinJithin P GPursuing Masters degree in Power systems from College of engineering, TrivandrumNR