13
dip To find list of sites whose DIP is in ABL sta To check quality of dip To refresh errors in DIP To see status of all DIP To change the name of DIP To deblock a particular DIP To find cell status To find if a particular cell has a got TS blo to find external alarms to find level 1& 2 alarms to find TG Value deblocking the tru To make TRU out of service To make TRU in service To find the status of CF of a particular site blocking the dxu To make DXU out of service TO make DXU in service

Win Fiol Command

Embed Size (px)

DESCRIPTION

BSS command for monitoring...

Citation preview

Page 1: Win Fiol Command

dipTo find list of sites whose DIP is in ABL state

To check quality of dip

To refresh errors in DIP

To see status of all DIPTo change the name of DIP

To deblock a particular DIP

To find cell status

To find if a particular cell has a got TS blockage

to find external alarmsto find level 1& 2 alarms

to find TG Value

deblocking the truTo make TRU out of serviceTo make TRU in serviceTo find the status of CF of a particular siteblocking the dxuTo make DXU out of serviceTO make DXU in service

Page 2: Win Fiol Command

Deblocking the DXUTo block deblock CFTo block a particular TSTo deblock a particular TSTo find CF fault codesTo find all fault codes CF and TRX faultsTo find all the CF Fault affected sites

To find if a particular TRU is in local mode

To find all fault codes CF and TRX faultsTo hault or activate a paricular cell

To find the list of devicesTo find MO statusTo find status of various TRX in a TG

To find property of TRXTo find software version of a site

To get list of devices attached to TG Value

To find cabinet typeTo find KLM and vc-12 valueProcedure to find a site is independent

To find out TEI value of a site and signallingTo find the power in a particular TXTo find site id through TG Value

To find log of a particular site

Page 3: Win Fiol Command

To test a particular managed object

To find overall status of a site

To find information about m/o device

To make UNCONFIG TS CONFIG provided the cell is not haltedTo load a paricular siteboth things can be done at the same timeTo change tx power of trx

To define a new DIP

To remove TS having LOOP TEST FAILED

To find status of link for aparticular BSC

Page 4: Win Fiol Command

To find out put pwer of a particular cell

To print DTX downlink data for a cell

To deblock a DIP whose SDIP Layer is manually blocke

Page 5: Win Fiol Command

TRX status

Page 6: Win Fiol Command

dtstp:dip=all;(don’t give a,b,c)dtstp:dip=all,state=abl;dtstp:digital path state printdtqup:dip=dip name;dtqup:digital path quality printdtqsr:dip=dip name,unacc,degr,sf;dtqsr:digital path quality supervision resetunacc:All parameters of unacceptable performance level is reset(ES,SES,DM)DEGR:all parameters of degraded performance level is resetdtqup:dip=all;dtpnc:dip=dip name,new dip=new dip name;dtpnc:digital path name changecell=cell designation which can have maximum of 7 charactersdtble:dip=dip name;dtble:digital path transmission functioning blocking end dfel5186rlcrp:cell=all;rlcrp:radio controlled cell resources print

SDCCH+CBCH=X

then there is no blockage or else there is a blockageWhy 32:Because in 1 TRU there are 8 TSallip:alcat=ext;allip:acl=a1;allip:acl=a2;allip:alarm functions alarm list printalcat:alarm categoryrxtcp:moty=rxotg,cell=name;rxtcp:radio x-ceiver administration TG to channel group<rxbli:mo=rxotrx-3-5,subord,force;rxese:mo=rxotrx-42-0,subord;rxesi:mo=rxotrx-42-0,subord;rxmsp:mo=rxocf-TG Value;rxbli:mo=rxotg-16,subord,force;rxese:mo=rxotg-16,subord;rxesi:mo=rxotg-16,subord;

qwerty@123

Divide X/8 and ADD this to BCCH and NOOFTCH if this is equal to 32(For 4 tru)

Page 7: Win Fiol Command

rxble:mo=rxotg-16,subord;rxbli:mo=rxocf-TG Value;rxbli:mo=rxots-53-1-1;rxble:mo=rxots-53-1-1;rxmfp:mo=rxocf-502,faulty;rxmfp:mo=rxotg-23,subord,faulty;rxasp:moty=rxocf ;rxasp:radio x ceiver administration managed object alarm status printrxasp:mo=rxotrx-trx value;rxasp:radio x-ceiver administration managed object alarm situation printrxmfp:mo=rxotg-23,subord,faulty;rlstc:cell=cell name,state=halted,active;rlstc:radio control cell state changerxapp:mo=rxotg-TG Value;rxmsp:mo=rxocf-109,subord;rxmsp:mo=rxotrx-6-7,subord;if the status of TRU are unconfig and site is not halted check may be TRU are wrongly definedand check the tx power of transmitterrxmop:mo=RXOTrx-406-1;rxmop:mo=rxotg-TG Value;see last 2 digits of SWVERDLD and SWVERACT to know softaware versionrxapp:mo=rxotg-TG Value;rxapp:radio x-ceiver administration abis path status printrxmfp:mo=rxocf-TG Value;tpcop:sdip=0etm2;radep:dev=RBLT2-2239(From this command find the value of SNTINL RBLT2 is one device of slave sideradep:dev=RBLT2-2239(From this command find the value of SNTINL ntcop:snt=etm2-3;Fromt this command the site which has got the same value of SNTINL is the masterrxmop:mo=rxocf-TG Value;rxmop:mo=rxotx-TX Value of a site;rxmop:mo=rxotx-402-2;rxasp:mo=rxotrx-TEI Value;step1:type F8 to create a log filestep2:aploc;

Page 8: Win Fiol Command

alogfind -a starttime -e startdate(year/month/day) -b closetime -g closedateclose log filerxtei:mo=mo value(rxotrx,rxorx,rxorx,rxots)rxtei:radio x-ceiver administration test of mo initiaterxtee:mo=mo value(rxotrx,rxorx,rxorx,rxots)rxcdp:mo=rxotg-TG Value;rxcdp:radio x ceiver administaration m/o configuration datarxmdp:mo=

THIS COMMAND IS VALID FOR CF,DP,TRXC,TSrxmdp:mo=rxocf-125;rxbli:mo=rxotg-16,subord,force;rxese:mo=rxotg-16,subord;rxesi:mo=rxotg-16,subord;rxble:mo=rxotg-16,subord;rxmoc:mo=rxotrx-TEI VALUE,mpwr=power;rxmoc:radio x-ceiver administration m/o object data changeNTCOP:snt=etm2-3; 1etm value in which that dip needs to be createdntcop:switching network terminal connection data,printtpcop:sdip=0etm2; 2TPCOP:transmission function synchronous digital path connection data printdtdii:dip=dipname,snt=etm2-3,dipp=x; 3x-value corresponding to vc-12 for that particular KLMtpble:sdip=3etm2,lp=vc12-8; 4tpble:transmission func synchronous digital path,blocking endsdip:synchronous digital pathlp:lower order pathdtble:dip=dip name; 5dtble:digital path func blocking endrxbli:mo=rxots-53-1-1;rxble:mo=rxots-53-1-1;rlncp:radio controlled cell neighbour to cell printc7ltp:ls=all;ls:link set

Page 9: Win Fiol Command

rlcpp:cell=cell name;rlcpp:radio controlled cell configuration data print

rlcxp:cell=cell name;rlcxp:radio control cell config. DTX dowlink print

ON Discontinues downlink transmission is enabled in the BSC for the cell.

OFF Discontinues downlink transmission is disabled in the BSC for the cell.

dtdip:dip=dip name;note etm value and dipport(dipp value)tpble:sdip=4etm2,lp=vc12-dippvaluedtble:dip=dip name;dtstp:dip=dip name;

mstxpwr:bspwrb Base Station (BS) output power in dBm, for Broadcast Control Channel (BCCH) Radio Frequency (RF) channel number.The current Base Transceiver Station (BTS) version may have specific parameter restrictions. See "BTS parameter limitations" in OPERATION AND MAINTENANCE MANUAL for current BTS version.

This parameter is not valid for external cell. bspwrt Base Station output power in dBm, for the non-BCCH RF channel numbers. cell Cell designation mstxpwr Maximum transmit power for the Mobile Station (MS) on connection. sctype Subcell type.UL Underlaid subcellOL Overlaid subcell.

dtxd Discontinues downlink transmission.

Page 10: Win Fiol Command

rxcdp:mo=rxotg-tgvalue

Page 11: Win Fiol Command

TEI Terminal end point identifier

Page 12: Win Fiol Command

To delete a deviceto check the state of the device

to check etm no

To check TG value

Page 13: Win Fiol Command

blodi:dev=RTLTT2-4608&&-4639;stdep:dev=RTLTT2-4608&&-4639;

ntcop:snt=etm4-2;

rxmdp:dev= RBLT2-7809,moty=rxots;

dtdip:dip=dip name;