26
EP.NMINI Wiring Guide Version 1.02 Last Updated: 14-10-2014 1

Wiring Guide - Bricomp Hah/EntryPass/Manual/NMI… · Diode(1N4002) must be installed at the locking devices in order to protect against back EMF - + White/Blue (CM1) White (NC1)

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Wiring Guide - Bricomp Hah/EntryPass/Manual/NMI… · Diode(1N4002) must be installed at the locking devices in order to protect against back EMF - + White/Blue (CM1) White (NC1)

EP.NMINI

Wiring Guide

Version 1.02 Last Updated: 14-10-2014

1

Page 2: Wiring Guide - Bricomp Hah/EntryPass/Manual/NMI… · Diode(1N4002) must be installed at the locking devices in order to protect against back EMF - + White/Blue (CM1) White (NC1)

Note: See http://www.entrypass.net/ for updates, revisions, and download the latest installation manual There are currently 2 version of EntryPass Platform1 Access Control System available for different card number system 1) EntryPass Platform1 Access Control System (6 Digit Card Number System) cater for 6 digit card number installation 2)EntryPass Platform1 Access Control System (10 Digit Card Number System) cater for 10 digit card number installation For EntryPass Platform1 Access Control System to work correctly, both control panel and software MUST be using the same card number system This software installation manual might be updated without prior notice Please refer to separate EntryPass Platform1 User Manual for detail operation help. The Official EntryPass Platform1 User Manual can be downloaded from our website under “Download” section

Model: EP.NMINI

2

Page 3: Wiring Guide - Bricomp Hah/EntryPass/Manual/NMI… · Diode(1N4002) must be installed at the locking devices in order to protect against back EMF - + White/Blue (CM1) White (NC1)

Technical Support If you cannot find the answer to your question in this manual or in the Help files, we recommend you contact your system installer. Your installer is familiar with your system configuration and should be able to answer any of your questions. Should you need additional information, please call our Technical Support Help desk, Monday to Friday 9:00 AM to 6:00 PM (GMT +8:00) Method Details Phone + 60 (3) - 8068 1929 Fax + 60 (3) - 8068 1922 Internet www.entrypass.net Email [email protected]

Before you begin

Model: EP.NMINI

3

Page 4: Wiring Guide - Bricomp Hah/EntryPass/Manual/NMI… · Diode(1N4002) must be installed at the locking devices in order to protect against back EMF - + White/Blue (CM1) White (NC1)

CAUTION Battery may explode if mistreated. Do not recharge, disassemble or dispose of in fire. To prevent a risk of explosion do not pry the battery out with a metal or conductive tool.

Considerations Prior to Installation

Preparing Your EntryPass Controllers EntryPass controller contains numerous delicate electronic circuits and components which can become damaged as a result of electrostatic discharge (ESD). Thus, prior to installation, please follow the instruction below: •Observe precautions while handling the circuit board assembly by using proper grounding straps and handling precautions at all •Visually ensure no onboard parts is broken, damage or contains burn mark •Do not turn on the power supply until you completed all wiring and external add on devices installations

Instances of Non-Warranty •Damage due to natural disaster, accident or human cause. •Damage as a result of violating the conditions recommended in the user manual •Damage due to improper installation •Damage due to use of uncertified components •Damage due to use exceeding the permitted parameters

Model: EP.NMINI

4

Page 5: Wiring Guide - Bricomp Hah/EntryPass/Manual/NMI… · Diode(1N4002) must be installed at the locking devices in order to protect against back EMF - + White/Blue (CM1) White (NC1)

NMiNi Description

NMiNi Reader Keypad Display Unit

Networked Lock Control

Model: EP.NMINI

5

Page 6: Wiring Guide - Bricomp Hah/EntryPass/Manual/NMI… · Diode(1N4002) must be installed at the locking devices in order to protect against back EMF - + White/Blue (CM1) White (NC1)

NMiNi Color Description

NMiNi Reader Color Description

Red : +12VDC Black : GND / 0VDC Pink : Not In Used Black : GND / 0VDC Blue : Not In Used Brown : Not In Used White : Exit Reader D1 Green : Exit Reader DO Orange : Not In Used Yellow : Not In Used Grey : Not In Used Purple : Not In Used

Green : RS232 RX Separated White : RS232 TX Separated

Networked Lock Control (NLC) Description

Red / Yellow : +12VDC Black : GND / 0VDC Orange : Door Sensor Yellow : Not In Used Blue : Not In Used Pink : Push Button Red : +12VDC Black : GND / 0VDC Grey / Yellow : NO1 White / Blue : CM1 White : NC1 Brown : NO2 Grey : CM2 Green : NC2 Purple : +12Vdc Lock Purple : +12Vdc Lock Green : RS232 TX Separated White : RS232 RX Separated

Model: EP.NMINI

6

Page 7: Wiring Guide - Bricomp Hah/EntryPass/Manual/NMI… · Diode(1N4002) must be installed at the locking devices in order to protect against back EMF - + White/Blue (CM1) White (NC1)

NMiNi Reader Keypad Display Unit

White LCD Display

Enter Key

Numbered Keypad

Navigation Pad

LED Indicator

Model: EP.NMINI

7

Page 8: Wiring Guide - Bricomp Hah/EntryPass/Manual/NMI… · Diode(1N4002) must be installed at the locking devices in order to protect against back EMF - + White/Blue (CM1) White (NC1)

Networked Lock Control (NLC)

Backup Battery

8-Bits Dip Switch

Buzzer

Lock Relay

Wire Connector RJ-45 Network Port

Auxiliary Input

Auxiliary Communication Port

32-Bits Processor

Power LED

Reset Button Cold Start Button

Heart Beat LED

Communication LED

RJ-45 LED

8

Model: EP.NMINI

Page 9: Wiring Guide - Bricomp Hah/EntryPass/Manual/NMI… · Diode(1N4002) must be installed at the locking devices in order to protect against back EMF - + White/Blue (CM1) White (NC1)

Power Supply Unit Specification

Model: EP.NMINI

9

Power Supply Unit Specification: • Switching Power Supply • 12V DC • 3 Amp (Minimum)

ENTRYPASS

Page 10: Wiring Guide - Bricomp Hah/EntryPass/Manual/NMI… · Diode(1N4002) must be installed at the locking devices in order to protect against back EMF - + White/Blue (CM1) White (NC1)

Connecting NMINI to NLC

The distance from NMINI keypad reader to NLC should not more than 30 meter

Model: EP.NMINI

0 V +12 VDC

Green (RS 232)

White (RS 232)

Red (+12VDC)

Black (Gnd)

Green (RS 232)

White (RS 232)

Black (Gnd)

Red (12+VDC)

ENTRYPASS

Switching Mode Power Supply Unit

(12V DC, 3A Minimum)

10

Page 11: Wiring Guide - Bricomp Hah/EntryPass/Manual/NMI… · Diode(1N4002) must be installed at the locking devices in order to protect against back EMF - + White/Blue (CM1) White (NC1)

Connecting the Lock (NC), Breakglass and Keyswitch to NLC

Model: EP.NMINI

Diode(1N4002) must be installed at the locking devices in order to protect against back EMF

+-

White/Blue (CM1)

White (NC1)

0V

Emergency

Breakglass

Emergency

Keyswitch

Electro-Magnetic Lock

-+

ENTRYPASS

Purple (+12VDC)

Purple (+12VDC)

Switching Mode Power Supply Unit

(12V DC, 3A Minimum)

11

Page 12: Wiring Guide - Bricomp Hah/EntryPass/Manual/NMI… · Diode(1N4002) must be installed at the locking devices in order to protect against back EMF - + White/Blue (CM1) White (NC1)

Connecting the second lock (NC) if the door is a double leaf type (OPTIONAL)

+-

Grey (CM2)

Purple (+12VDC)

0V

Electro-Magnetic Lock

-+

ENTRYPASS

Purple (+12VDC)

Green (NC2)

Switching Mode Power Supply Unit

(12V DC, 3A Minimum)

Model: EP.NMINI

When the implementation is on double leaf type, it is advisable to use the second relay to control another lock in order to reduce the NLC onboard relay load

Note: To enable the relay 2 function, on the NMINI keypad reader, press: •F1 •123456 •01 Enter •01 Enter •07 Enter •1 Enter •ESC x3

12

Page 13: Wiring Guide - Bricomp Hah/EntryPass/Manual/NMI… · Diode(1N4002) must be installed at the locking devices in order to protect against back EMF - + White/Blue (CM1) White (NC1)

Connecting the Lock (NO)

Model: EP.NMINI

Diode(1N4002) must be installed at the locking devices in order to protect against back EMF

+-

White/Blue (CM1)

Grey/Yellow (NO1)

0V

Electro-Magnetic Lock (Drop Bolt)

-+

ENTRYPASS

Purple (+12VDC)

Purple (+12VDC)

Switching Mode Power Supply Unit

(12V DC, 3A Minimum)

13

Page 14: Wiring Guide - Bricomp Hah/EntryPass/Manual/NMI… · Diode(1N4002) must be installed at the locking devices in order to protect against back EMF - + White/Blue (CM1) White (NC1)

Connecting the second lock (NO) if the door is a double leaf type (OPTIONAL)

Note: To enable the relay 2 function, on the NMINI keypad reader, press: •F1 •123456 •01 Enter •01 Enter •07 Enter •1 Enter •ESC x3

Model: EP.NMINI

+-

Grey (CM2)

Purple (+12VDC)

0V

Electro-Magnetic Lock (Drop Bolt)

-+

ENTRYPASS

Purple (+12VDC)

Brown (NO2)

Switching Mode Power Supply Unit

(12V DC, 3A Minimum)

When the implementation is on double leaf type, it is advisable to use the second relay to control another lock in order to reduce the NLC onboard relay load

14

Page 15: Wiring Guide - Bricomp Hah/EntryPass/Manual/NMI… · Diode(1N4002) must be installed at the locking devices in order to protect against back EMF - + White/Blue (CM1) White (NC1)

Connecting the Door Sensor and Door Release Button/Push Button

Model: EP.NMINI

The distance from NLC to push button and door sensor should not more than 30 meter

Door Sensor Push Button

Orange (Door Sensor)

Pink (Push Button)

Black (Gnd)ENTRYPASS

15

Page 16: Wiring Guide - Bricomp Hah/EntryPass/Manual/NMI… · Diode(1N4002) must be installed at the locking devices in order to protect against back EMF - + White/Blue (CM1) White (NC1)

Model: EP.NMINI

Connecting the Exit Reader – NMINI reader as an exit reader

To use NMINI/MINI on exit reader side, you must enable the READER MODE function on the programming mode

To configure MINI as a READER Mode, press: •F1 •123456 •01 Enter •01 Enter •05 Enter •1 Enter •ESC x3

To configure NMINI as a READER Mode, press: •F1 •123456 •01 Enter •01 Enter •04 Enter •1 Enter •ESC x3

0 V +12 VDC

Exit Reader

Switching Mode Power Supply Unit

(12V DC, 3A Minimum)

Green (D0)

White (D1)

Black (Gnd)

Red (+12VDC)

Black (Gnd)

Red (+12VDC)

Orange (RCLK)

Yellow (RDAT)

16

Page 17: Wiring Guide - Bricomp Hah/EntryPass/Manual/NMI… · Diode(1N4002) must be installed at the locking devices in order to protect against back EMF - + White/Blue (CM1) White (NC1)

Connecting the Exit Reader – 3rd Party Reader

0 V +12 VDC

Green (D0)

White (D1)

Black (Gnd)

Red (+12VDC)

Green (D0)

White (D1)

Exit Reader

Black (Gnd)

Red (+12VDC)

Switching Mode Power Supply Unit

(12V DC, 3A Minimum)

Model: EP.NMINI

The distance from NMINI keypad reader to exit reader should not more than 10 meter

17

Page 18: Wiring Guide - Bricomp Hah/EntryPass/Manual/NMI… · Diode(1N4002) must be installed at the locking devices in order to protect against back EMF - + White/Blue (CM1) White (NC1)

Connecting to the PC (EntryPass Platform1 Access Control System)

The distance from NLC to network switch should not more than 150 meter

Model: EP.NMINI

Cat-5 Cat-5

Network Switch

ENTRYPASS

EntryPass Platform1 Access Control System

18

Page 19: Wiring Guide - Bricomp Hah/EntryPass/Manual/NMI… · Diode(1N4002) must be installed at the locking devices in order to protect against back EMF - + White/Blue (CM1) White (NC1)

Connecting to the power supply unit

Model: EP.NMINI

0 V +12 VDC

Red/Yellow (+12VDC)

Black (Gnd)ENTRYPASS

Switching Mode Power Supply Unit

(12V DC, 3A Minimum)

19

Page 20: Wiring Guide - Bricomp Hah/EntryPass/Manual/NMI… · Diode(1N4002) must be installed at the locking devices in order to protect against back EMF - + White/Blue (CM1) White (NC1)

Complete overview

Model: EP.NMINI

+-

White/Blue (CM1)White (NC1)

0V

Emergency

Breakglass

Emergency

Keyswitch

Electro-Magnetic Lock

-+

Purple (+12VDC)Purple (+12VDC)

White (RS 232)Green (RS 232)

Door Sensor

Push Button

Pink (Push Button)Orange (Door Sensor)

Black (Gnd)

Black (Gnd)

Red (+12VDC)

Exit Reader

Green (D0)White (D1)

Red (+12VDC)

Black (Gnd)Red/Yellow (+12VDC)

+12 VDC

Switching Mode Power Supply Unit

(12V DC, 3A Minimum)

ENTRYPASS

Cat - 5

Cat

- 5

Network

SwitchEntryPass Platform1

Server Access

Control System

e

e

20

Page 21: Wiring Guide - Bricomp Hah/EntryPass/Manual/NMI… · Diode(1N4002) must be installed at the locking devices in order to protect against back EMF - + White/Blue (CM1) White (NC1)

Model: EP.NMINI

Before connecting to the EntryPass Platform1 Access Control System Fa

cto

ry D

efa

ult

IP A

dd

ress

Sub

ne

t M

ask

Gat

eway

Serv

er

IP

Advisable to perform format memory for the

first time you turn on the

power

To configure the EP.NMINI controller IP

address

To configure the EP.NMINI

controller subnet mask

if required

To configure the EP.NMINI

controller Gateway if required

To configure the Server IP base on the EntryPass Platform1

computer IP address

Before you begin to connect to the EntryPass Platform1 Access Control System, please make sure all the wiring connection is correct. On the NMINI keypad, please make sure the following setting

has been done:

21

Page 22: Wiring Guide - Bricomp Hah/EntryPass/Manual/NMI… · Diode(1N4002) must be installed at the locking devices in order to protect against back EMF - + White/Blue (CM1) White (NC1)

NMINI Programming Mode

Admin Pin •Enter programming mode •01 Enter •01 Enter •01 Enter •Key in new admin pin (6 digits) •ESC X3 Security Level •Enter programming mode •01 Enter •01 Enter •02 Enter •1 Enter (Press 1 to set it ON or press 0 to set it OFF) •ESC X3 Unit Address •Enter programming mode •01 Enter •01 Enter •03 Enter •Key in the new unit address (000 – 254 sets) •ESC X3 Reader Mode •Enter programming mode •01 Enter •01 Enter •04 Enter •1 Enter (Press 1 to set it ON or press 0 to set it OFF) •ESC X3 Standalone •Enter programming mode •01 Enter •01 Enter •05 Enter •1 Enter (Press 1 to set it ON or press 0 to set it OFF) •ESC X3

MiNi Location •Enter programming mode •01 Enter •01 Enter •06 Enter •1 Enter (Press 1 to set it ON or press 0 to set it OFF) •ESC X3 Relay2 Function •Enter programming mode •01 Enter •01 Enter •07 Enter •1 Enter (Press 1 to set it ON or pres 0 to set it OFF) •ESC X3 IP Address •Enter programming mode •01 Enter •01 Enter •08 Enter •Key in the new IP address •ESC X3 Subnet Mask •Enter programming mode •01 Enter •01 Enter •09 Enter •Key in the new Subnet Mask •ESC X3 Gateway •Enter programming mode •01 Enter •01 Enter •10 Enter •Key in the new Gateway •ESC X3

Port Number •Enter programming mode •01 Enter •01 Enter •11 Enter •Key in the new Port number •ESC X3 Server IP •Enter programming mode •01 Enter •01 Enter •12 Enter •Key in the new Server IP •ESC X3 Disable Wizard •Enter programming mode •01 Enter •01 Enter •13 Enter •1 Enter (Press 1 to set it ON or press 0 to set it OFF) •ESC X3 Ethernet Speed •Enter programming mode •01 Enter •01 Enter •14 Enter •Press 1 to set to 100Mbps (default) or press 0 to set to 10 Mbps •ESC X3

Model: EP.NMINI

To enter programming mode, press: •F1 •123456 (default admin pin)

22

Page 23: Wiring Guide - Bricomp Hah/EntryPass/Manual/NMI… · Diode(1N4002) must be installed at the locking devices in order to protect against back EMF - + White/Blue (CM1) White (NC1)

Inhibit Mode •Enter programming mode •01 Enter •02 Enter •01 Enter •1 Enter (Press 1 to set it ON or press 0 to set it OFF) •ESC X3 Security Mode •Enter programming mode •01 Enter •02 Enter •02 Enter •0 Enter (Press 1 to set it ON or press 0 to set it OFF) •ESC X3 Site Code 1 •Enter programming mode •01 Enter •02 Enter •03 Enter •Key in the new site code (4 digits) •ESC X3 Site Code 2 •Enter programming mode •01 Enter •02 Enter •04 Enter •Key in the new site code (4 digits) •ESC X3 Site Code 3 •Enter programming mode •01 Enter •02 Enter •05 Enter •Key in the new site code (4 digits) •ESC X3

Door Pin 1 •Enter programming mode •01 Enter •02 Enter •06 Enter •Key in the new door pin (6 digits) •09 Enter •001 •ESC X3 Door Pin 2 •Enter programming mode •01 Enter •02 Enter •07 Enter •Key in the new door pin (6 digits) •10 Enter •001 •ESC X3 Door Pin 3 •Enter programming mode •01 Enter •02 Enter •08 Enter •Key in the new door pin (6 digits) •11 Enter •001 •ESC X3 Door Pin 1 Tz •Enter programming mode •01 Enter •02 Enter •09 Enter •Key in the new door pin timezone (000 – 255) •ESC X3

Door Pin 2 Tz •Enter programming mode •01 Enter •02 Enter •10 Enter •Key in the new door pin timezone (000 – 255) •ESC X3 Door Pin 3 Tz •Enter programming mode •01 Enter •02 Enter •11 Enter •Key in the new door pin timezone (000 – 255) •ESC X3 Exit Button Tz •Enter programming mode •01 Enter •02 Enter •12 Enter •Key in the new exit button timezone (000 – 255) •ESC X3 Auto Release Tz •Enter programming mode •01 Enter •02 Enter •13 Enter •Key in the new auto release timezone (000 – 255) •ESC X3 Release Time •Enter programming mode •01 Enter •02 Enter •14 Enter •Key in the new release time (00 – 99) •ESC X3

Model: EP.NMINI

NMINI Programming Mode

23

Page 24: Wiring Guide - Bricomp Hah/EntryPass/Manual/NMI… · Diode(1N4002) must be installed at the locking devices in order to protect against back EMF - + White/Blue (CM1) White (NC1)

Open Time •Enter programming mode •01 Enter •02 Enter •15 Enter •Key in the new open time (00 – 99) •ESC X3 Pin Trials •Enter programming mode •01 Enter •02 Enter •16 Enter •Key in the new pin trials (00 – 09) •ESC X3 Card+Pin Tz •Enter programming mode •01 Enter •02 Enter •17 Enter •Key in the new card+pin timezone (000 – 255) •ESC X3 Date Setting •Enter programming mode •01 Enter •03 Enter •Key in the new date (DDMMYY) •ESC X2 Time Setting •Enter programming mode •01 Enter •04 Enter •Key in the new time (HHMMSS) •ESC X2

Reset Password •Enter programming mode •01 Enter •05 Enter •01 Enter •ESC X2 Reset Door Data •Enter programming mode •01 Enter •05 Enter •02 Enter •ESC X2 Format Memory •Enter programming mode •01 Enter •05 Enter •03 Enter •When finish formatting, a beep sound will be heard •ESC X2 Factory Default •Enter programming mode •01 Enter •05 Enter •04 Enter •1 Enter •Key in the current admin pin •When finish performing factory default, a beep sound will be heard Install Card •Enter programming mode •02 Enter •01 Enter •01 Enter •Key in the card number (6 digits) •ESC X3

Delete Card •Enter programming mode •02 Enter •01 Enter •02 Enter •Key in the card number (6 digits) •ESC X3 View Card •Enter programming mode •02 Enter •01 Enter •03 Enter •Key in the card number (6 digits) •ESC X4 Quick Install •Enter programming mode •02 Enter •01 Enter •04 Enter •Flash all the cards to be installed (card by card) •ESC X4 Quick Delete •Enter programming mode •02 Enter •01 Enter •05 Enter •Flash all the cards to be deleted (card by card) •ESC X4 Reset Card Pin •Enter programming mode •02 Enter •01 Enter •06 Enter •Key in the card number that need to perform pin reset •ESC X3

Model: EP.NMINI

NMINI Programming Mode

24

Page 25: Wiring Guide - Bricomp Hah/EntryPass/Manual/NMI… · Diode(1N4002) must be installed at the locking devices in order to protect against back EMF - + White/Blue (CM1) White (NC1)

Reset Lockout •Enter programming mode •02 Enter •01 Enter •07 Enter •1 Enter •ESC X3 Reset Lockout Time •Enter programming mode •02 Enter •01 Enter •08 Enter •Key in the reset lockout time (HHMM) •ESC X3 Total Card •Enter programming mode •02 Enter •01 Enter •09 Enter •ESC X3 Transaction •Enter programming mode •02 Enter •02 Enter •Press F3 button to view the next transaction event or F1 button to go back to previous transaction event •ESC X3 Info Menu •Enter programming mode •03 Enter •ESC X2 Extra Info Menu •Enter programming mode •04 Enter •ESC X2

Card Number •Enter programming mode •05 Enter •01 Enter •Flash the card to check •ESC X3 Card Binary •Enter programming mode •05 Enter •02 Enter •Flash the card to check •ESC X3 Help Line Info •Enter programming mode •05 Enter •03 Enter •ESC X3

Model: EP.NMINI

NMINI Programming Mode

25

Page 26: Wiring Guide - Bricomp Hah/EntryPass/Manual/NMI… · Diode(1N4002) must be installed at the locking devices in order to protect against back EMF - + White/Blue (CM1) White (NC1)

Cabling Information

Communication Data Signal Max Distance Description

NMINI to NLC RS232 10m (30 ft)

22 AWG, 2 Pairs, Shielded

NMINI to Exit Reader Wiegand 10m (30 ft)

22 AWG, 2 Pairs, Shielded

NLC to Computer or Network Switch

Network 100m (300 ft)

24AWG, 4 Pairs (Cat 5e)

NLC to Electro-Magnetic Lock

Power 30m (100 ft)

18 AWG, 1 Pair

NLC to Push Button Contact 30m (100 ft)

22AWG, 1 Pair

NLC to Door Sensor Contact 30m (100 ft)

22AWG, 1 Pair

Model: EP.NMINI