3
World Best Efficiency TB series are world’s only and most advanced single stage centrifugal blowers based on high speed focused specialized technology. Concurrently designed impeller, motor, bearing and VFD are the key of our high efficiency. Due to it’s high rotational speed requirements, all components should have been redesigned considering high speed and high temperature conditions. Bearing life time, rotor stability, motor heat generation and cooling, new high speed VFD development, reliable high speed surge protection, high rise-to-surge feature; all those were new challenge in order to overcome high speed difficulties. Now, TB series are the world’s only blower which satisfies all technical requirements and efficiency. Oilless Operation Thanks to air foil bearings, ISO 8573-1 class 0 is over satisfied. Flow Meter Installed Bell mouth flow meter is installed and shows instantaneous flow rate with ±0.5% tolerance Real High Rise-to-Surge The most advanced current based control method enables an active high rise-to-surge advantage. This is a critical feature required by pneumatic conveying and MBR applications. Compactness TB series are world’s most compact blower products reducing construction costs and space requirements. Semi-Permanent Life TB series can be used permanently with proper maintenance without performance degradation. Stainless steel impellers and packaging insure durability and allow for permanent life. 18kW ~ 448kW (25 ~ 600HP) 13.4 ~ 330㎥/min (459 ~11,654cfm) 2,000 ~ 20,000mmAq (2.84 ~ 28.4psi) This catalog is made from recycled paper 2 Pole permanent magnet Scroll Impeller Winding Stator Thrust disk & Thrust bearing Radial airfoil bearing Shaft

World Best Efficiency - KTurbo-Net.€¦ ·  · 2015-07-24World Best Efficiency ... motor heat generation and cooling, new high speed VFD development, reliable high speed surge protection,

Embed Size (px)

Citation preview

World Best EfficiencyTB series are world’s only and most advanced single stage centrifugal blowers based on high speed focused specialized technology. Concurrently designed impeller, motor, bearing and VFD are the key of our high efficiency.Due to it ’s high rotational speed requirements, all components should have been redesigned considering high speed and high temperature conditions. Bearing life time, rotor stability, motor heat generation and cooling, new high speed VFD development, reliable high speed surge protection, high rise-to-surge feature; all those were new challenge in order to overcome high speed difficulties.Now, TB series are the world’s only blower which satisfies all technical requirements and efficiency.

Oilless Operation Thanks to air foil bearings, ISO 8573-1 class 0 is over satisfied.

Flow Meter InstalledBell mouth flow meter is installed and shows instantaneous flow rate with ±0.5% tolerance

Real High Rise-to-SurgeThe most advanced current based control method enables an active high rise-to-surge advantage. This is a critical feature required by pneumatic conveying and MBR applications.

CompactnessTB series are world’s most compact blower products reducing construction costs and space requirements.

Semi-Permanent Life TB series can be used permanently with proper maintenance without performance degradation.Stainless steel impellers and packaging insure durability and allow for permanent life.

18kW ~ 448kW (25 ~ 600HP)

13.4 ~ 330㎥/min (459 ~11,654cfm)2,000 ~ 20,000mmAq (2.84 ~ 28.4psi)

This catalog is made from

recycled paper

2 Pole permanent magnet

Scroll

Impeller

Winding

Stator

Thrust disk & Thrust bearing Radial airfoil bearing

Shaft

Model Designation Performance Curve

Field Performance Test

TB : Turbo Blower

TC : standard 7bar turbo compressor

TCL : Low pressure turbo compressor

V : Variable DiffuserF : Fixed Diffuser

S : StandardE : ECO

Intake option (A / B / C)

HPDesign Pressure (bar)

TB 400 0.8 V S A

1. Test condition calculation

2. Runing on the test condition (volume flow rate, discharge pressure)

- Flow rate is measured by intake bell mouth or other type of flowmeter.

- Discharge static pressure is measured after diffusing cone.

- Total kW is measured at the package inlet electric input after the harmonic filter.

- Ambient temperature and pressure is measured by sensors specially tuned for ambient condition.

3. Calculate total efficiency.

- Humidity effect is included when mass flow rate is calculated.

where, k = 1.4Cp=1004 J/[kg·K]

m=mass flow rate[kg/s]Q=inlet volume flow rate[㎥/s]

Package Layout

Package Dimensions

Standard Maximum efficiency mode

EcoAll heat from VFD and motor is mixed with intake air, and increases inlet temperature of the impeller. (usually ~ 7 degrees C).I f scroll and pipe is not insulated, the inlet t e m p e r a t u r e i n c r e a s e s m o r e ( o v e r 1 0 c ) . This increased inlet temperature lowers the compression efficiency 3-4%.

Model SuctionFlange

MainDischarge

Flange

Cooling AirFlange

Package Footprint (L×W×H) Filter Amount

Weight

inch (mm) inch (mm) inch (mm) Kg (lbs)

TB25-0.8 6" (150A) 4" (100A) 5" (125A) 31.89 (810) 31.89 (810) 49.96 (1269) 2 343 (756)TB30-0.8 6" (150A) 4" (100A) 5" (125A) 31.89 (810) 31.89 (810) 49.96 (1269) 2 353 (778)TB50-0.6 8" (200A) 6" (150A) 5" (125A) 31.89 (810) 31.89 (810) 49.96 (1269) 2 348 (767)TB50-0.8 8" (200A) 6" (150A) 5" (125A) 31.89 (810) 31.89 (810) 49.96 (1269) 2 348 (767)TB50-1.5 6" (150A) 4" (100A) 5" (125A) 31.89 (810) 31.89 (810) 49.96 (1269) 2 353 (778)TB75-0.6 10" (250A) 8" (200A) 5" (125A) 31.89 (810) 31.89 (810) 49.96 (1269) 2 353 (778)TB75-0.8 10" (250A) 8" (200A) 5" (125A) 31.89 (810) 31.89 (810) 49.96 (1269) 2 409 (901)TB75-1.5 8" (200A) 6" (150A) 5" (125A) 31.89 (810) 31.89 (810) 49.96 (1269) 2 409 (901)

TB100-0.4 20" (500A) 16" (400A) 6" (150A) 43.31 (1100) 43.31 (1100) 62.52 (1588) 6 582 (1283)TB100-0.6 12" (300A) 10" (250A) 5" (125A) 31.89 (810) 31.89 (810) 49.96 (1269) 3 457 (1007)TB100-0.8 12" (300A) 10" (250A) 5" (125A) 31.89 (810) 31.89 (810) 49.96 (1269) 2 409 (901)TB100-1.0 10" (250A) 8" (200A) 5" (125A) 31.89 (810) 31.89 (810) 49.96 (1269) 2 464 (1022)TB150-0.4 20" (500A) 16" (400A) 8" (200A) 51.18 (1300) 51.18 (1300) 69.13 (1756) 6 876 (1931)TB150-0.6 16" (400A) 12" (300A) 6" (150A) 43.31 (1100) 43.31 (1100) 62.52 (1588) 6 705 (1554)TB150-0.8 12" (300A) 10" (250A) 6" (150A) 43.31 (1100) 43.31 (1100) 62.52 (1588) 6 605 (1333)TB150-1.0 12" (300A) 10" (250A) 6" (150A) 43.31 (1100) 43.31 (1100) 62.52 (1588) 6 605 (1333)TB150-1.5 10" (250A) 8" (200A) 6" (150A) 43.31 (1100) 43.31 (1100) 62.52 (1588) 6 625 (1377)TB200-0.4 20" (500A) 16" (400A) 8" (200A) 51.18 (1300) 51.18 (1300) 69.13 (1756) 8 876 (1931)TB200-0.6 20" (500A) 16" (400A) 6" (150A) 43.31 (1100) 43.31 (1100) 62.52 (1588) 6 655 (1444)TB200-0.8 16" (400A) 12" (300A) 6" (150A) 43.31 (1100) 43.31 (1100) 62.52 (1588) 6 705 (1554)TB200-1.0 12" (300A) 10" (250A) 6" (150A) 43.31 (1100) 43.31 (1100) 62.52 (1588) 6 605 (1333)TB200-1.2 12" (300A) 10" (250A) 6" (150A) 43.31 (1100) 43.31 (1100) 62.52 (1588) 6 605 (1333)TB250-0.8 16" (400A) 12" (300A) 6" (150A) 43.31 (1100) 43.31 (1100) 62.52 (1588) 8 705 (1554)TB250-1.5 16" (400A) 12" (300A) 8" (200A) 51.18 (1300) 51.18 (1300) 69.13 (1756) 6 925 (2039)TB300-0.4 28" (700A) 24" (600A) 10" (250A) 78.74 (2000) 78.74 (2000) 78.74 (2000) 15 1359 (2996)TB300-0.6 24" (600A) 20" (500A) 8" (200A) 51.18 (1300) 51.18 (1300) 69.13 (1756) 8 990 (2182)TB300-0.8 20" (500A) 16" (400A) 8" (200A) 51.18 (1300) 51.18 (1300) 69.13 (1756) 8 990 (2182)TB300-1.0 20" (500A) 16" (400A) 8" (200A) 51.18 (1300) 51.18 (1300) 69.13 (1756) 8 900 (1984)TB300-1.2 20" (500A) 16" (400A) 8" (200A) 51.18 (1300) 51.18 (1300) 69.13 (1756) 8 900 (1984)TB300-1.5 16" (400A) 12" (300A) 8" (200A) 51.18 (1300) 51.18 (1300) 69.13 (1756) 6 925 (2039)TB400-0.6 28" (700A) 24" (600A) 10" (250A) 78.74 (2000) 78.74 (2000) 78.74 (2000) 15 1359 (2996)TB400-0.8 24" (600A) 20" (500A) 8" (200A) 51.18 (1300) 51.18 (1300) 69.13 (1756) 8 990 (2182)TB400-1.0 20" (500A) 16" (400A) 8" (200A) 51.18 (1300) 51.18 (1300) 69.13 (1756) 8 950 (2094)TB400-1.3 20" (500A) 16" (400A) 8" (200A) 51.18 (1300) 51.18 (1300) 69.13 (1756) 8 950 (2094)

TB500-0.8 28" (700A) 24" (600A) 10" (250A) 78.74 (2000) 78.74 (2000) 78.74 (2000) 15 1564 (3448)TB600-0.8 28" (700A) 24" (600A) 10" (250A) 78.74 (2000) 78.74 (2000) 78.74 (2000) 15 1564 (3448)

KTURBO INC. Headquarter (Factory, R&D and C/S center) 631, Bugang Buyoung cheongwon Chungbuk, 363-941, KOREA / TEL: +82-43- 275-7573 / FAX: 630-406-1538 / E-mail: [email protected]

KTURBO USA INC. /USA (Factory & C/S center) 1183 Pierson Dr, Unit 118, Batavia, IL 60510 USA / TEL: 630-406-1473 / FAX: 630-406-1538 / E-mail: [email protected]

KTURBO Europe GmbH Europe (C/S Center) Kurfuersten Platz 34, 60486 Frankfurt am Main, Germany / TEL: +49-69-778914 / FAX: +49-69-778918 / E-mail: [email protected]