28
Jfs280613/1328 version 15 08/02/ 2016 1 WORLD Energy regulation guideline

WORLD Energy regulation guideline - Home - Nidec Nederland ... · WORLD Energy regulation guideline. ... o Starting performances in conformity with H and N type of NBR or A, ... NBR

Embed Size (px)

Citation preview

Jfs280613/1328 version 15 08/02/ 2016

1

WORLD Energy regulation guideline

Jfs280613/1328 version 15 08/02/ 2016

2

1. INTRODUCTION 3 2. EUROPE EU (plus Swiss and Turkey) 3 3. USA and CANADA 4 4. BRAZIL 8 5. Others Latin-America countries

5.1 ARGENTINA 9 5.2 CHILE 10 5.3 MEXICO 10

6. CHINA 11 7. KOREA 12 8. AUSTRALIA, NEW ZEELAND 13 9. INDIA 14 10. JAPAN 14 11. ISRAËL 15 12. TAIWAN 16 13. SAUDI ARABIA 14. MINIMUM MANDATORY EFFICIENCIES DATA PER COUNTRY

14.1 EUROPE 17 14.2 USA/CANADA 18 14.3 BRAZIL 22 14.4 CHINA 23 14.5 KOREA 24 14.6 AUSTRALIA/NEW ZEELAND 25 14.7 JAPAN 26

15. INFORMATION FOR ORDERING 27

Jfs280613/1328 version 15 08/02/ 2016

3

1. INTRODUCTION More and more countries are introducing regulations for reducing energy consumption and CO₂. As such, electric motors are concerned. Purpose of this guide is to provide as much information regarding local regulations in the world and so offer best LEROY-SOMER motors solution.

2. EUROPE EU (plus Swiss and Turkey)

Regulation in Europe

This is the directive known as "eco-design", usually named ErP, 2009/125CE of 10/21/2009 with regulations for electrical motors 640/2009CE imposing to place on the market only IE2 motors from 06/16/2011.

Regulation in Swiss

This is the Energy Order 730.01 of 24/06/2009. It requires to place on the market only IE2 motors from 07/01/2011.

Regulation in Turkey

This regulation SGM 2012/2 of 02/07/2012 requires to place on the market only IE2 motors from 04/02/2012. Switzerland and Turkey have adopted the same regulation as the EEC. It is therefore the same technical constraints: regulation, standards, and performances. For the three economic areas, second efficiency step is IE3 (or IE2 + drive) mandatory from:

- 01/01/2015 for motors with power ≥ 7.5 kW - 01/01/2017 for motors with power ≥ 0.75 kW

Concerned products

o AC three-phases motors o 0.75 to 375 kW o Voltage < 1000V 50 or 50/60Hz o 2, 4 & 6 pole o All IP o All mounting o Continuous duty

Non concerned products

o Motors which are fully integrated in another product (rotor/stator)

Jfs280613/1328 version 15 08/02/ 2016

4

o Motors designed to operate when fully submerged in liquid o Motors designed to operate at ambient air temperature > 40°C o Motors designed to operate at altitude > 1000 m o Motors designed to operate at maximum operating temperature > 400°C o Safety motors conforming to directive ATEX 94/9/EC o Brake motors (excepted for Switzerland) o On-board motors (road, rail, water)

Motor name-plate and labelling

Note that there is no requirement of label related to motors. Only IE code is mandatory plus efficiency value (IEC 60034-30).

Other contraint

Manufacturing year must be plated.

Marking All products placed on the EEC market must be CE marked. To be CE, the product must comply with all European related directives. For electrical motors the directives are:

- 2009/125/EC (and regulation 640/2009) - 2006/95/EC

LS products to propose

IMfinity® IE3 and IE2 standard motors comply with first phase of regulations and guidelines above. This IFT motors generation includes ranges LSES, FLSES, PLSES and LSMV IE2.

3. USA & CANADA

Regulation

This EISA regulation « Energy Independence and Security Act » is U.S. law, signed December 19, 2007. This regulation replaces and cancels the previous one, EPAct (Energy Policy Act), and also expands its scope to motors not affected previously. The level of performance increases from "High Efficiency" -equivalent to IE2 60Hz- to "Premium Efficiency" -equivalent to 60 Hz IE3. Rules are defined in the "CFR" (Code of Federal Regulation), reference 10 CFR Part 431.31 For Canada, regulation is "Energy Efficiency Act SC 1992, ch.36. The same rules apply as EISA. USA : regulation applies to motors placed on the market from December 19, 2010. CANADA : regulation applies to motors placed on the market from April 12, 2012 and those in stock since January 1, 2011. Does not apply to motors in stock before 01/01/2011.

Jfs280613/1328 version 15 08/02/ 2016

5

Concerned products

Regulation is applied to general purpose motors. All motors from subtype 1, 1 to 200 HP previously covered by EPAct (High Efficiency), should now comply with Premium Efficiency performances as defined in Table 12-12 of NEMA MG 1. Only motors with voltage 230V or 460V 60Hz and 575V 60Hz for Canada must meet the Premium performance. All motors from subtype 2 that were not covered by EPAct regulation must be now comply with high efficiency performance as defined in NEMA MG 1Table 12-11 of. This particularly concerns the following motors:

o U-frame o Design C o Close coupled pump motors o Round body (footless) o Vertical solid shaft normal trust motors o 8 pole o Polyphase motor less than 600V (other 230V or 460V) o Fire pumps motors 1 to 200 HP o Motors from 201 to 500 HP that were not previously covered by EPAct

IMPORTANT: EISA regulation concerns all motors such as ATEX, TEFV or ODP motors, all mounting system, all IEC or NEMA base.

Non concerned products

o Fractional power < 1HP o NEMA base < 143T (90 for IEC) o Design D (high slip) o Adjustable with optimized windings (can not be line started as Design A or B) o Special or adapted motors who can’t be used as general purpose motors

(definite & special purpose motors) o Non-continuos duty o Geared or brake motors o Submersible motors o Single phase motors o Multi speed motors o DC motors o TENV and TEAO enclosures (IC410 and 418 of IEC)

Variable speed used motors

Different cases : o Motors specially designed for variable speed as can be, for example, defined

in IEC 60034-25 (over-insulation, insulated bearings, ...) : this is typical "inverter duty" motor, therefore not covered by EISA. No constraint of minimum performance required.

Jfs280613/1328 version 15 08/02/ 2016

6

o Standard "general purpose" motors, 460V 60Hz, fixed speed, who can also be used in variable speed. Inside EISA scope, therefore IE3 PREMIUM with exceptions specified in the regulations (round housing, design C, ....).

o LSMV special case: this motor is only for variable speed use. As this motor is dedicated for variable speed not covered by EISA, there is no constraint of efficiency level.

Motor name-plate and labelling

EISA regulation imposes additional obligations, not linked to NEMA, on the motor name-plate : o « CC » number (compliance

certification). LEROY-SOMER file number is : CC055B

o Product year o Efficiency at load 4/4 with :

« Nominal Efficiency xx.x% » or « Nom. Eff. xx.x% » or « NEMA Nom. Eff. xx.x% »

o label is commercial and not include inside CFR. However, CFR propose

to use label. Using this label, which is optional, means that the product complies with the regulation.

Other plated information

Canada and USA : CSA label link with letters C and US means product is certified for Americans and Canadian markets, following American and Canadian relevant standards. If a product has features from more than one kind of products (e.g. electrical equipment including a combustion fuel), the mark indicates compliance with all relevant standards.

This label concerns only finished products as may be complete machines. A motor is only one component and is therefore not affected by this labelling. REMARK: c CSA us and c UL us have same meaning but one is made by CSA and other by UL.

Label c UR us is optional and indicates compliance with Canadian and United States requirements. UL encourage manufacturers distributing products with UL Recognized Mark for both countries to use combined marking.

For Canada, minimum requirement is c UR us or c CSA us. Both are also possible.

Components covered by UL Recognized Mark program are dedicated to installation in another device, system or final product. It will be installed in the factory, not on the field,

Jfs280613/1328 version 15 08/02/ 2016

7

and its performances capabilities might be limited and limit its use. When a product or complete system containing UL Recognized Component is evaluated, the evaluation process of the final product can be rationalized. LEROY-SOMER choice is : c CSA us + c UR us.

Canada: label of compliance with energy efficiency (optional)

USA: label of compliance with energy efficiency (optional)

Other constraint

Country of origin must be indicated on the motor.

From June 1, 2016 new motors affected by regulations :

o 2, 4, 6 & 8 pole o 1-500 HP (0.75 to 375 kW) o Design or C (N or H CIS) o Frame size mini 3 digit frame 56 + version IP55 o Design A 200 to 500 HP o with heating resistors o with winding sealed (resin?) o Fully integrated in a machine with common parts (motor for gearbox) o TENV (unventilated IC410) o immersible o brake motors o with forced ventilation

These motors will have efficiencies in line with appended table based Design (A, B or C) Are still outside scope of the following engines:

o Non-vented to the air flow o Cooled water o Submersibles o specific variable speed motors

Note that the DOE recognizes that specific motors for inverters, those with permanent magnets, those switch-reluctance motors that are already helping to save energy and as for now there is no rule or standard for testing, are outside the scope of regulation at this time. Note: to be able to sale a motor inside the scope of the regulation in the USA and / or Canada, it must be registered with the Department of Energy.

Jfs280613/1328 version 15 08/02/ 2016

8

LS products to propose

Motors range IMfinity® IE3 : LSES 2, 4 and 6 pole from 0.75 to 160 kW and LSMV and GH.

4. BRAZIL

Regulation

This is the INMETRO regulation. From December 08, 2009, it is mandatory to supply Brazilian market only with high efficiency motors. Commercialised motors must be registered with INMETRO organization. Efficiency level is equivalent to IE2 60Hz. Important: without such homologation, no motor can be placed on Brazilian market, single or mounted on a machine. Only ranges certified motors can be sold on this market.

Concerned products

o AC three-phases motors o Voltage ≤ 600 V o 60 Hz or 50/60 Hz able to work on 60Hz supply network fixe or variable speed o Power 0.75 to 185 kW for 2 and 4 pole o Power 0.75 to 150 kW for 6 pole o Power 0.75 to 110 kW for 8 pole o Duty S1 or assimilated (as S3 FM ≥ 80% for example) following NBR

7094/2000 o Starting performances in conformity with H and N type of NBR or A, B and C of

NEMA. o Standard Motors used at variable speed. o Totally enclosed type (IP55) self-ventilated with fan on shaft motor or forced

ventilation. o ATEX « n » motors

Non concerned products

o Water cooled motors o Permanents magnets motors o ODP motors as IP23 o Smock extraction motors o ATEX « D » and « e » motors o Variable speed motors with duty S2 to S10 (S9) and/or supplied with drive

Remark: LSMV motors, with or without brake, are out of the regulation scope. However, it is necessary to add information on import licence: « Unregulated motor specially designed to operate with drive, S9 ».

Jfs280613/1328 version 15 08/02/ 2016

9

Motor name-plate and labelling

Following label sticker must be placed on top of fan cover motor that have been approved by INMETRO.

Other constraint

NBR 17094-1 reference standard must be plated.

LS products to propose

LSES aluminium motors LS2 60Hz, 2 & 4 pole from 0.75 to 185kW. Warning, this motors are different from those for Europe or North America. According to Table: PET / 004-MOT (registration file 001507/2013 for 2P and 001508/2013 for 4P) Note: higher efficiency class equivalent to IE3 is not yet mandatory but may be imposed from 2018 or 2020.

Jfs280613/1328 version 15 08/02/ 2016

10

5. MEXICO Mexico energy efficiency is CONUEE (Comision Nacional para el Uso Eficiente de la Energia). Regarding efficiency, the standard is NOM-016-ENER. Motors placed on the market since December 19, 2010 must comply with regulation. Minimum required is PREMIUM (IE3 60Hz).

Concerned motors :

o AC three-phases motors o Voltage ≤ 600V - Frequency 60Hz o Power 0.75 kW up to 375 kW o Open or closed enclosure o Horizontal or vertical mounting position o Continous duty

Non concerned motors :

o Brake motors o Non continuous duty o Designed motors for variable speed

Motor name-plate and labelling :

Following label is mandatory and is supplied by ANCE. This surveillance authority request registration program with tests, ….

LS product to propose

LS motors are not registered with the local authorities, but we can consider that in view of trade agreements on the free movement of goods within the economic area Canada / USA / Mexico, a registered and licensed motor for the first two countries to be used also for Mexico. Possibility to propose for this market: The same as those for the USA (see above)

Jfs280613/1328 version 15 08/02/ 2016

11

6. CHINA

Efficiency Classes and performance method measurement are defined inside GB18613-2012 standard. This is equivalent to IEC 60034-30 Ed.1

Regulation :

From September 1, 2012 and no later than October 1, 2013, motors placed on the market must comply with grade 3 (IE2) minimum. From September 1, 2016 minimum efficiency must reach grade 2 (IE3) for power ≥ 7.5 kW and from September 1, 2017 for ≥ 0.75 kW motors.

Concerned motors :

o AC three-phases motors o Voltage ≤ 1000 V o Frequency 50 Hz o Power 0.75 to 375 kW o Polarity : 2, 4 & 6 o Single speed o S1 duty or assimilated o Torque curve N type o All mounting position o construction IP55 self ventilated o General purpose or ATEX

Motor name-plate and labelling :

Motors must be registered with the "ENERGY CENTER LABEL". A label (sticker) must be fixed on the motor. Remark : First label following GB 18613-2006 requesting Grade 2 (equivalent eff1 / IE2) is available until September 2013.

LS products to propose

IMfinity® aluminium motors IE3 range LSES: 2 pole 2.2 up to 90kW, 4 pole 1.1 up to 90 kW, 6 pole 0.75 up to 55 kW.

7. SOUTH KOREA Regulation name is KEMCO (Korean Energy Management Corporation). From January 2010, It is mandatory to supply the Korean market only with high efficiency motors that must have been registered and validated by KEMCO. Required efficiency performances are IE2 60Hz.

Jfs280613/1328 version 15 08/02/ 2016

12

Concerned motors :

o AC three-pahes motors o Voltage ≤ 600 V o Frequency 60 Hz o Power 0.75 to 200 kW o Polarity : 2, 4, 6 & 8 o S1 duty or assimilated o Variable speed driving a pumps or a ventilators o All mounting position o TENV and TEAO enclosures (IC410 and 418 of IEC) ATEX o Standard options like brake, sensors, …..

Non concerned motors :

o IC418 and IC410 motors o Variable speed driving other than pumps and ventilators o Installed on boats o Assembly on re-exported machines

Motor name-plate and labelling :

Following label must be fixed on the motors that were approved by KEMCO.

LS product to propose LS motors are not registered with local authorities

Remark : from 2015, minimum efficiency level should be IE3.

8. AUSTRALIA & NEW ZEELAND Regulation name, common to both countries, is E3 (Equipment Energy Efficiency for Australia) and EECA (Energy Efficiency Conservation Authority for New Zeeland). This regulation started from October 1st, 2001 and updated April 1st, 2006. Efficiencies motors are measurable following two standards: Method A, based on the IEEE 112-B or IEC 60034-2-1 and Method B, based on IEC 60034-2. Minimum mandatory efficiency level is IE2 (Method A2) or equivalent eff1 (Method B2). IE3 (Method A3) performance level is optional. Motors for Australian and New Zealand markets are required to be registered with the authorities of either country. LEROY-SOMER has registered LSES aluminium motors 2 & 4 pole 0.75 to 165 kW. Motors list available on following link: https://reg.energyrating.gov.au/comparator/product_types/54/search/ In 2013, it is expected that performance level increase to IE3 (tables A3 or B3 of regulation).

Concerned motors :

Jfs280613/1328 version 15 08/02/ 2016

13

o AC three-phases motors o Voltage : ≤ 1100V o Frequency : no information in regulation but network frequency 50Hz o Power 0.73 to 185 kW o Polarité : 2, 4, 6 & 8 o Duty S1 or assimilated o All mounting position o TENV and TEAO enclosures (IC410 and 418 of IEC) o Standard options like sensors, brake …

Non concerned motors :

o Submersible motors o Motors with very special design o Gearboxe integrated motors o Variable speed or multi-speed motors o Rewound motors o Shirt duty

Local standards for efficiency measurement :

AS1359 – part 102.1: efficiency measurement according to IEC 60034-2. AS/NZS1359.5 – part 102.3: efficiency measurement according to IEC 60034-2-1 or IEEE 112-B

Motor name-plate and labelling :

Note that there is no requirement of label related to motors.

LS products to propose

Motors range IMfinity® IE2 and IE3 : LSES 2 and 4 from 0.75 to 165 kW and LSMV. Warning, these motors are different from European motors (adapted winding).

9. INDIA A new standard has been voted in 2011. It is IS12615. It is exactly the same definition as CEI 60034-30 Ed.1. Only two additional parameters: torque and starting current and maximum current and minimum speed at full load. Although it is possible that Indian authorities impose efficiency level in 2014, to date, there is only one recommendation:

- From 2011 IE2 efficiency - From 2014 IE3 efficiency

CAUTION: choice of IE2 or IE3 motors is only voluntary.

Jfs280613/1328 version 15 08/02/ 2016

14

10. JAPAN The name of the Japanese regulation is TOP Runner. From 1 April 2015, all motors placed on the market must be IE3 class efficiency. The motors are those of the scope of JIS C 4034-30 standard (which is equivalent to the CEI60034-30)

• Concerned motors : o Frequency 50Hz, 60Hz and 50/60 Hz o singlespeed o voltage up to 1000V o nominal power 0.75kW to 375kW o polarity: 2P, 4P & 6P o S1 or S3 o capable of operating directly on network

• Non concerned motors: o Motors completely integrated in a machine and which cannot be tested separately o Motors designed for the variable speed that cannot operate on the network. o Motors with special insulation class (H, N, R and 250 ° C) o Special motors for textile machinery requiring a very high starting torque o Marine motors o Motors totally immersed in liquid o Motors with strong slip o Motors for water gates o Motors caned o Motors specially designed to operate at temperatures <20 ° C o Motors with forced ventilation

Notes:

• For the same magnetic circuit, a motor wound H class supply less power than F class insulation as take up more space in the slots and less place for copper. There is generally a gap of one size between a motor insulated F class and a motor insulated H class. • There are several frequencies and voltages depending of the geographic position. Usually, voltages are as follows 200V-50Hz / 60Hz-200V / 220V-60Hz for small and medium power (usually ≤ 30kW but it is up to 75kW). For high power, it is more generally requested 400V-50Hz / 60Hz 400V / 440V-60Hz. • In fact, votltages/ frequencies 200V-220V 50Hz and 60Hz, are still required by the market. Non-presence of the 200V-60Hz line is generally accepted by the market, it is accommodating the two lines-50Hz 200V / 220V-60Hz even though the actual usage is 200V-60Hz. • If a motor is plated with two voltages/frequencies 200V-50Hz and 220V-60Hz, it will have IE3 efficiency at 200V-50Hz and at 220V-60Hz.

Jfs280613/1328 version 15 08/02/ 2016

15

• If a motor is plated with three voltages/frequencies 200V 50Hz / 200V 60Hz / 220V 60Hz , it should have IE3 efficiency at 200V-50Hz and 220V-60Hz. At 200V-60Hz, an "intermediate" efficiency is defined in the attached table. This table is valid for voltages 400V-50Hz / 60Hz 400V / 440V-60Hz.

• Motors labelling: There is no requirement to label product. However, regulation request a special nbameplate. The Japanese Association of engine manufacturers created a label that is optional.

• LS product to propose: IMfinity® motors IE3 LSES, FLSES et PLSES , 2 - 4 et 6 pole. Careful, following all voltages frequencies combinations, it is necessary to use a motor with a suitable winding.

11. ISRAËL Efficiency regulation is SI 5289. Since 2008, it is mandatory to supply the market only with IE2 motors. It’s expected to move to IE3 in 2015. Concerned motors: those of IEC60034-30 but for powers 0.75 to 185 kW plus 8 pole (out of the standard today).

TOP Runner motor

Jfs280613/1328 version 15 08/02/ 2016

16

12. TAIWAN Similar to European regulation. IE2 efficiency class mandatory from 1 January 2015 and IE3 from 1 July 2016.

Concerned motors : 2, 4 and 6 pole from 0.75 to 200kW Note: the local voltage is usually 380V-60Hz, therefore it is necessary to propose IMfinity® motors specially wound.

13. SAUDIA ARABIA The SAUDI ENERGY EFFICIENCY PROGRAM (SEEP) is as follow : All motors which will enter in Kingdom Saudi Arabia should achieve efficiency class:

- IE2 from 07/01/2015 - IE3 as of 01/01/2017

It is mandatory to register its production to export its to Saudi Arabia. Efficiency class (SASO IEC 60034-30 ) :

The standard applies to the following only: o Single speed, three phase, 60Hz, cage induction stand-alone motors that:

o Have a rated voltage up to 1000V (applies also to motors rated for two or more voltages and/or frequencies)

o Have a rated output power between 0.75kW and 375 kW

o Have either 2, 4 or 6 poles

o Are rated on the basis of either duty type S1(continuous duty) or S3 (intermittent periodic duty) with a rated cyclic duration factor of 80% or higher

o Are capable of operating direct on-line

o Are rated for operating conditions in accordance with IEC 60034-1 clause 6 (Motors with flanges, feet and/or shafts with mechanical dimensions different from IEC 60072-1 are covered)

Excluding the following types: o Motors made solely for converter operation in accordance with IEC 60034-25

o Motors completely integrated into a machine (for example pump, fan and compressor) that cannot be tested separately from the machine

o Brake motors, gear motors and wound rotor motors

o Torque motors (corresponding to IEC design H, e.g. gate motor & crane motor)

o Motors specifically designed to operate: in maximum operating temperatures above 400°C

In potentially explosive atmospheres (e.g. explosion proof motors)

Jfs280613/1328 version 15 08/02/ 2016

17

Wholly immersed in a liquid (e.g. submergible motors)

With cooling from external equipment (e.g. air over motors or liquid cooling motors)

In an enclosed container and part of an integrated system (e.g. canned motor)

• LS product to propose: IMfinity® motors IE2 and IE3 LSES, FLSES et PLSES, 2 - 4 et 6 pole.

Jfs280613/1328 version 15 08/02/ 2016

18

14. EFFICIENCIES TABLES

14.1 EUROPE (IEC 60034-30-1 and ErP)

Table 1 Minimum nominal efficiency for IE2 efficiency level (50Hz)

2 4 6

0,75 77,4 79,6 75,9

1,1 79,6 81,4 78,1

1,5 81,3 82,8 79,8

2,2 83,2 84,3 81,8

3 84,6 85,5 83,3

4 85,8 86,6 84,6

5,5 87,0 87,7 86,0

7,5 88,1 88,7 87,2

11 89,4 89,8 88,7

15 90,3 90,6 89,7

18,5 90,9 91,2 90,4

22 91,3 91,6 90,9

30 92,0 92,3 91,7

37 92,5 92,7 92,2

45 92,9 93,1 92,7

55 93,2 93,5 93,1

75 93,8 94,0 93,7

90 94,1 94,2 94,0

110 94,3 94,5 94,3

132 94,6 94,7 94,6

160 94,8 94,9 94,8

200 à 375 95,0 95,1 95,0

numbre of poleNominal power

(kW)

Jfs280613/1328 version 15 08/02/ 2016

19

Table 2 Minimum nominal efficiency for IE3 efficiency level (50Hz)

2 4 6

0,75 80,7 82,5 78,9

1,1 82,7 84,1 81,0

1,5 84,2 85,3 82,5

2,2 85,9 86,7 84,3

3 87,1 87,7 85,6

4 88,1 88,6 86,8

5,5 89,2 89,6 88,0

7,5 90,1 90,4 89,1

11 91,2 91,4 90,3

15 91,9 92,1 91,2

18,5 92,4 92,6 91,7

22 92,7 93,0 92,2

30 93,3 93,6 92,9

37 93,7 93,9 93,3

45 94,0 94,2 93,7

55 94,3 94,6 94,1

75 94,7 95,0 94,6

90 95,0 95,2 94,9

110 95,2 95,4 95,1

132 95,4 95,6 95,4

160 95,6 95,8 95,6

200 à 375 95,8 96,0 95,8

numbre of poleNominal power

(kW)

Jfs280613/1328 version 15 08/02/ 2016

20

14.2 USA & CANADA (NEMA MG-1 and EISA)

NEMA MG-1 Table 12-12 Full Load Efficiencies Subtype 1 – Premium Efficiency Motors

Rated 600 Volts or less (Random Wound)

Jfs280613/1328 version 15 08/02/ 2016

21

NEMA MG-1 Table 12-11 Full Load Efficiencies Subtype 2 – High Efficiency Motors

Jfs280613/1328 version 15 08/02/ 2016

22

Jfs280613/1328 version 15 08/02/ 2016

23

14.3 BRAZIL (NBR 17094 : 2008 and INMETRO)

Jfs280613/1328 version 15 08/02/ 2016

24

14.4 CHINE (GB 18613 - 2012)

Table 1

The energy efficiency grade of motors

Rated power/ Kw

Full load (100%) < 1000V 50Hz

Grade1 (~ IE4) Grade2 (=IE3) Grade3 (=IE2)

2P 4P 6P 2P 4P 6P 2P 4P 6P

0.75 84.9 85.6 83.1 80.7 82.5 78.9 77.4 79.6 75.9

1.1 86.7 87.4 84.1 82.7 84.1 81.0 79.6 81.4 78.1

1.5 87.5 88.1 86.2 84.2 85.3 82.5 81.3 82.8 79.8

2.2 89.1 89.7 87.1 85.9 86.7 84.3 83.2 84.3 81.8

3 89.7 90.3 88.7 87.1 87.7 85.6 84.6 85.5 83.3

4 90.3 90.9 89.7 88.1 88.6 86.8 85.8 86.6 84.6

5.5 91.5 92.1 89.5 89.2 89.6 88.0 87.0 87.7 86.0

7.5 92.1 92.6 90.2 90.1 90.4 89.1 88.1 88.7 87.2

11 93.0 93.6 91.5 91.2 91.4 90.3 89.4 89.8 88.7

15 93.4 94.0 92.5 91.9 92.1 91.2 90.3 90.6 89.7

18.5 93.8 94.3 93.1 92.4 92.6 91.7 90.9 91.2 90.4

22 94.4 94.7 93.9 92.7 93.0 92.2 91.3 91.6 90.9

30 94.5 95.0 94.3 93.3 93.6 92.9 92.0 92.3 91.7

37 94.8 95.3 94.6 93.7 93.9 93.3 92.5 92.7 92.2

45 95.1 95.6 94.9 94.0 94.2 93.7 92.9 93.1 92.7

55 95.4 95.8 95.2 94.3 94.6 94.1 93.2 93.5 93.1

75 95.6 96.0 95.4 94.7 95.0 94.6 93.8 94.0 93.7

90 95.8 96.2 95.6 95.0 95.2 94.9 94.1 94.2 94.0

110 96.0 96.4 95.6 95.2 95.4 95.1 94.3 94.5 94.3

132 96.0 96.5 95.8 95.4 95.6 95.4 94.6 94.7 94.6

160 96.2 96.5 96.0 95.6 95.8 95.6 94.8 94.9 94.8

200 96.3 96.6 96.1 95.8 96.0 95.8 95.0 95.1 95.0

250 96.4 96.7 96.1 95.8 96.0 95.8 95.0 95.1 95.0

315 96.5 96.8 96.1 95.8 96.0 95.8 95.0 95.1 95.0

355~375 96.6 96.8 96.1 95.8 96.0 95.8 95.0 95.1 95.0

Jfs280613/1328 version 15 08/02/ 2016

25

14.5 KOREA (CEI 60034-2-1 and KEMCO)

Jfs280613/1328 version 15 08/02/ 2016

26

14.6 AUSTRALIA / NEW ZEELAND (AS/NZS1359 part 102.3 and E3)

Table A2: Efficiency Levels for Three Phase Electric Motors Test Method A (IEEE 112-B or CEI 60034-2-1)

Rated output kW

Minimum efficiency %

2 pole 4 pole 6 pole 8 pole

0.73 78.8 80.5 76.0 71.8

0.75 78.8 80.5 76.0 71.8

1.1 80.6 82.2 78.3 74.7

1.5 82.6 83.5 79.9 76.8

2.2 84.0 84.9 81.9 79.4

3 85.3 86.0 83.5 81.3

4 86.3 87.0 84.7 82.8

5.5 87.2 87.9 86.1 84.5

7.5 88.3 88.9 87.3 86.0

11 89.5 89.9 88.7 87.7

15 90.3 90.8 89.6 88.9

18.5 90.8 91.2 90.3 89.7

22 91.2 91.6 90.8 90.2

30 92.0 92.3 91.6 91.2

37 92.5 92.8 92.2 91.8

45 92.9 93.1 92.7 92.4

55 93.2 93.5 93.1 92.9

75 93.9 94.0 93.7 93.7

90 94.2 94.4 94.2 94.1

110 94.5 94.7 94.5 94.5

132 94.8 94.9 94.8 94.8

150 95.0 95.2 95.1 95.2

< 185 95.0 95.2 95.1 95.2

Jfs280613/1328 version 15 08/02/ 2016

27

14.6 JAPAN :

Jfs280613/1328 version 15 08/02/ 2016

28

15. INFORMATION TO ORDER A MOTOR Regulations of each country or geographical areas are different, with different standard and different values of efficiency level. Each ordered motor must be adapted according to final destination in order to comply with local regulations. For this reason, it is mandatory to specify country of destination if outside Europe.

More information ? Contact : Jean-François SOGUEL [email protected]