7
WTCB IfJ ----- " BELGIAN BUILDING RESEARCH INSTITUTE CSTC INSTITUTI ON RECOGNIZED BY APPLICATION OF THE DECREE-LAW OF JANUARY THE 30th, 1947 042 -TEST - Test centre: 8-1342 Limelette, avenue P. Holoffe 2] Tel : (32) 2 655 77 11 Fax: (32) 2 653 07 29 - Offices : B-1932 Sint-Stevens-Woluwe. Lozenberg 7 Tel : (32) 2 716 4211 Fax ; (32)2 725 32 12 - Head office: B-1 000 Brussels, Rue du Lombard 42 Tel : (32) 2 502 66 90 Fax; (32) 2 502 81 80 VAT nO: BE 407.695.057 Pagel17 N°DE,ATA,RE: DE 631xB063 Labo: AC5438 LABORATORY of ACOUSTICS TEST REPORT Test sample: 2012-17-00312 REQUESTED BY: Insulco Rue Buisson Aux Loups, IA B - 1400 Nivelles Contacts: Requested by: BBR! Y. de Baenst M. VanDamme Tests carried out: Laboratory measurement of impact sound insulation of floors and of the reduction of impact noise by floor coverings on a heavyweight standard floor. Brandmark: insulit Bi+7 References: EN ISO 10140-3:2010 Acoustics - Measurement of sound insulation in buildings and of building elements - Part 3: Measurement of impact sound insulation EN ISO 717-2:1996 Acoustics-Rating of sound insulation in buildings and of building elements - Part 2: Impact sound insulation (ISO 717-2:1996) Date and reference of the request: 1210412012 Date of receipt oftbe sample(s): 2210312012 Test date: 25104/ 2012 Drafting date of the report: 2510612012 This report with its annexes contains 7 pages. It may only be reproduced in its entirety. Each page ofthe original report has been stamped (in red) by the laboratory and initialised by the head of the laboratory. The results and findings are only valid for the tested samples. D No sample D Sample(s) submitted to a destructive test lil Sample(s) to be removed from our laboratories 10 calender days after sending of the report, unless a written request is received by the demander of the test Technical responsable, The Head ofthe laboratory, r C.S.T.C. c.J :t -' P.Huart ' ';la-Damme v---- / Technical Assistant: M. Dubois - .

WTCB IfJ - Potichupotichu.cz/wp-content/uploads/2014/06/potichu-insulco-insulit-7-test... · N°DE,ATA,RE: DE 631xB063 N° Labo: AC5438 LABORATORY of ACOUSTICS TEST REPORT N° Test

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: WTCB IfJ - Potichupotichu.cz/wp-content/uploads/2014/06/potichu-insulco-insulit-7-test... · N°DE,ATA,RE: DE 631xB063 N° Labo: AC5438 LABORATORY of ACOUSTICS TEST REPORT N° Test

WTCB

IfJ -----

" BELGIAN BUILDING RESEARCH INSTITUTE

CSTC INSTITUTION RECOGNIZED BY APPLICATION OF THE DECREE-LAW OF JANUARY THE 30th, 1947

N° 042 -TEST

- Test centre: 8-1342 Limelette, avenue P. Holoffe 2] Tel : (32) 2 655 77 11 Fax: (32) 2 653 07 29 - Offices : B-1932 Sint-Stevens-Woluwe. Lozenberg 7 Tel : (32) 2 716 4211 Fax ; (32)2 725 32 12 - Head office: B-1 000 Brussels, Rue du Lombard 42 Tel : (32) 2 502 66 90 Fax; (32) 2 502 81 80

VAT nO: BE 407.695.057 Pagel17

N°DE,ATA,RE: DE 631xB063 N° Labo: AC5438

LABORATORY of ACOUSTICS TEST REPORT N° Test sample: 2012-17-00312

REQUESTED BY: Insulco Rue Buisson Aux Loups, IA B - 1400 Nivelles

Contacts: Requested by: BBR! Y. de Baenst M. VanDamme

Tests carried out: Laboratory measurement of impact sound insulation of floors and of the reduction of impact noise by floor coverings on a heavyweight standard floor.

Brandmark: insulit Bi+7

References: EN ISO 10140-3:2010 Acoustics - Measurement of sound insulation in buildings and of building elements - Part 3:

Measurement of impact sound insulation EN ISO 717-2:1996 Acoustics-Rating of sound insulation in buildings and of building elements - Part 2: Impact

sound insulation (ISO 717-2:1996)

Date and reference of the request: 1210412012 Date of receipt oftbe sample(s): 2210312012 Test date: 25104/2012

Drafting date of the report: 2510612012

This report with its annexes contains 7 pages. It may only be reproduced in its entirety. Each page ofthe original report has been stamped (in red) by the laboratory and initialised by the head of the laboratory. The results and findings are only valid for the tested samples. D No sample D Sample(s) submitted to a destructive test lil Sample(s) to be removed from our laboratories 10 calender days after sending of the report, unless a written

request is received by the demander of the test

Technical responsable, The Head ofthe laboratory,

r C.S.T.C.

~~ ~ c.J

:t ~ -' P.Huart ' ~ . ';la-Damme v---- / Technical Assistant: M. Dubois - .

Page 2: WTCB IfJ - Potichupotichu.cz/wp-content/uploads/2014/06/potichu-insulco-insulit-7-test... · N°DE,ATA,RE: DE 631xB063 N° Labo: AC5438 LABORATORY of ACOUSTICS TEST REPORT N° Test

BELGIAN BUILDING RESEARCH INSTITUTE

1. Test equipment TEST EQUIPMENT BAANDMAAK 2 microphones 1/2" BrOel & Kjc:er type 4190 2 pre-amplifiers for microphone BrOel & Kjmr type 2669-L

One power supply for microphones BrOel & Kjrer type 2829 One rotat ing microphone set-up Norsonic Nor265

AcqUIsition system Norsonic Nor850 Dist ributed Multichannel System

Measurement software Norsonic Nor850 Building Acoustic Software

One calibration source pistonphone BrOel & Kjcer type 4228 One standardised tapping machine BrOel & Kjcer type 3207

2. The precision of the measurement results

Is subjecl 01 sludy wilhin AHWG of Isorre 43/Se 2IWG 18 (preparing a revised ISO/PWI1 4D-2 )

3. Description of the test element

DE 631xB063 ACS438

Page 2/8

This description is given by the producer of the test element and Is not guaranteed by the laboratory. The equivalence between the tested product in this report and the commercial/sed product is the sale responsability of the producer.

GENERAL DESCRIPTION

Complex of floating screed conSisting of. from top to bottom: 1. A traditional screed, 8 cm. 2. A membrane lnsulit Bi+7 - double I layer of cross link polyolefine foam wilh closed cells and with a pyramidal structure +/- 3,5 mm assembled on a acoustical felt with low dynamic stiffness. 3. A concrete thermal leveling layer ± 5 cm.

COMPOSITION OF THE TESTELEMENT

Only parts of the table below can be made unreadable in copies of this report, e.g . If some data are confidential.

+7

+. +5

~ +4

+3

+2

~ :: -3

-4

thickness

BOmm

3.50 mm

4mm

SOmm

1800.0 kgfm3

33.0 kgfm3

50.0 kg/mJ

360.0 kg/mJ

surface mass

144.0 kg/m~

0.12 kg/m~

0.20 kg/m~

18.0 kgfm~

Screed

Crosslink polyolefine foam with closed cells and with a pyramidal structure

Acoustical lelt with low dynamic sliHness

Belopor - rigid thermal1eveling layer

Tolallhickness of the layers on top of the basic floor'" 137.7 mm (calculated value)

Total surface mass on top of the basic ((oor == 162.5 kg/m 2 (calculated value)

REMARKS

Page 3: WTCB IfJ - Potichupotichu.cz/wp-content/uploads/2014/06/potichu-insulco-insulit-7-test... · N°DE,ATA,RE: DE 631xB063 N° Labo: AC5438 LABORATORY of ACOUSTICS TEST REPORT N° Test

REDUCTION OF IMPACT SOUND PRESSURE LEVEL AFFAIBLISSEMENT ACOUSTIQUE BRUT / CONTACTGELUIDNIVEAUREDUCTIE

EN ISO 10 140-3:20 10 AcoLlstics - Measurement of sound insul ation in buildings and o fhui lding elements - Part 3: Measurement of impact sound insulal ion

EN ISO 7 17-2: 1996 Acoustics-Rati ng of sound insu lati on in buildings and of bui lding clements - Part 2: Impact sOllnd insu lat ion (1S0 717-2: 1(96)

client: Insu lco Rue Buisson Aux Loups, 1 A 6 - 1400 Nivelles

area S of test specimen: (oppervlakle S proefmonster I surface de rechanlilion S)

receiving room:

11 .50 m2

6

DE: DE 631 x6063 PV: AC5438

date test: 25/04/2012 page: 318

T= 19.0 °C air humidity: 46.0 %

(onlvangslruim le I salle de reception) 62.4 m3 n° sample: 2012-17-003/2

f .<lL

..J <I

30+--+--~~--~~------------~-+--~J-----------~

10+-~--~~--~U-~~-----+--+-~--+-~--~--~--~

0 § . ~ ~

00 • 8 § 00 8 00 ~ .<lLw = 26 dB ~ • :;; M 8 N ~ ~ • ~

C,., = -12 dB f [Hz]

L'>L';n= 14dB

Description by the producer - Beschrijving door de fabrikant - Description par Ie fabriguant Complex 01 Iloating screed consisting of, Irom top to bottom: 1. A traditional screed, 8 cm.

§ :;: 8 00 • • :;; N N

2. A membrane Insulit 6i+7 - doublel layer 01 crosslink polyoleline loam with closed cells and with a pyramidal structure +1- 3,5 mm assembled on a acoustical lell with low dynamic stiffness. 3. A concrete thermal leveling layer ± 5 cm.

Characteristics bearing test floor - Beschrijving draaglestvloer - Description de la daJle d'essai Reinforced concrete slab 14 cm thickness I 14 cm dikke gewapende betonplaatl dalle en beton arme de 14 cm d'epaisseur.

WETENSCHAPPEUJK EN TECHNISCH

CENTRUM VODR HEr BOUWBEDAIJF

laboratorium Akoestiek

Lombardstraat 42

8 ·1000 BRUSSEL

CENTRE SCIENTIFIQUE ET TECHNIQUE

DE LA CONSTRUCTION

Laboratoire Acoustique

Rue du Lombard 42

8-1000 BRUXElLES

Page 4: WTCB IfJ - Potichupotichu.cz/wp-content/uploads/2014/06/potichu-insulco-insulit-7-test... · N°DE,ATA,RE: DE 631xB063 N° Labo: AC5438 LABORATORY of ACOUSTICS TEST REPORT N° Test

REDUCTION OF IMPACT SOUND PRESSURE LEVEL AFFAIBLISSEMENT ACOUSTIQUE BRUT / CONTACTGELUIDNIVEAUREDUCTIE

EN ISO 10 140-3:2010 Acoustics - Measurement of sound insulat ion in huiJd ings and of hui ld ing element.s - Part 3: Measurement of impact sound insulation

EN ISO 7 17-2: 1996 Acoustics-Rating of sound insulation in hu ildings and of huilding elements - Part 2: Impact sound insulation (ISO 717-2:1996)

client: Insulco Rue Buisson Aux Loups, 1 A B - 1400 Nivelles

DE: DE 631 xB063 PV: AC5438

date test: 25104/2012 page: 416

area S 01 test specimen: 11.50 m' T= 19.0 °C air humidity = 46.0 % (oppervlakle S proelmonSler I surface de I'echantillon S)

receiving room: B (ontvangstruimte I salle de reception) 62.4 m' n° sample: 2012-17-003/2

f

Ln,w = 51 dB

70~~--r-~~--~------~~----~--r-~~-----,

I I : !

W 0; i ' I I 60 +-I--I----->\~ .. y--\-,+---t-, -+-, ---l-------r---+-+-I -+------+--+!!--I

0 1 , CT i '~I I 1 I I '

I , '- i i i ' I

T i ' "" -~~Q~, I 50 +--+--+-~--~--__ -3~,-~ __ ~~------r-~--------I

~ , I ' : '-' i~ ,~~~-e' i:,~! , __ III I I ,

~40+-----'~~'--~-+I --~I -+-~--+--+:~--~' ~~~o-+ ____ -; &:: I I f"Q, I '-, :

...J I ' : :,1 i !~->-: ! I ! I : ~

30~+I -+~~------~----+-~i------~'1 ~b~

II " I

I 1 I

t-i--' ~! ~~=P==n==9-~ 20 ' . " I r : I, / I

10 f---L1---+----'-f,1 -- ,~ 1 ~'t4~ I l l ~ IV- I .

, I ,

f [Hz]

C, = 1 dB EN ISO 717 reference curve

Description by the producer - Beschrijving door de labrikant - Description par Ie labriguant Complex of floating screed consisting of, from top to bottom: 1. A trad itional screed, 8 em. 2. A membrane Insulil Bi+7 - doublel layer of crosslink polyolefine foam with closed cells and with a pyramidal structure +/- 3,5 mm assembled on a acoustical felt with low dynamic stiffness. 3, A concrete lhermalleveling layer ± 5 em.

Characteristics bearing test Iloor - Beschrijving draagtestvloer - Description de la dalie d'essai Reinlorced concrete slab 14 cm thickness 114 cm dikke gewapende betonplaat 1 dalle en beton arme de 14 cm d'epaisseur.

WETENSCHAPPElIJK EN TECHNISCH

CENTRUM VOOR HET BOUWBEDRIJF

Laboratorium Akoesliek

Lombardstraat 42

8-1000 BRUSSEL

-----

" CENTRE SCIENTIFIQUE ET TECHNIQUE

DE LA CONSTRUCTION

Laboratoire AcousLique

Rue du lombard 42

8-1000 BRUXELLES

Page 5: WTCB IfJ - Potichupotichu.cz/wp-content/uploads/2014/06/potichu-insulco-insulit-7-test... · N°DE,ATA,RE: DE 631xB063 N° Labo: AC5438 LABORATORY of ACOUSTICS TEST REPORT N° Test

The standardised impact sound insulation in the laboratory Ln is determined according to

~EN ISO 10140-3:2010 Acoustics - Measurement of sound insulation in buildings and of building elements - Part 3: Measurement of impact sound insulation~

A detailed description of the measuring procedures can be found in this standard. In simple terms, the determination principle can be summarized as follows :

The impact sound is generated by the standardised tapping machine (lNith steel-headed hammers) lNhich is set successively at various positions on the test floor. For each position, sound pressure measurements are carried out with the help of a continually rotating microphone in the measuring cell located beneath the floor. Measurements are done during at least one complete rotation and in three different planes of rotation. One thus obtains an integration over time and space of the sound pressure level spectrum, lNhich results in an average sound pressure level. The reverberalion time in the receiving room is measured, lNhich permits one to calculate the correction term to be integrated into the fonnula for calculating the standardised impact sound level :

lNith:

p::;;~~ip~+iOiOg (A I A,)i

Lpm = the average pressure level in the receiving room, in dB (reference 20 Micro Pal ; Au = reference surface 10 m2; A = the equivalent absorption-surface of the receiving room in ml.

2. Determination of the standardised impact sound level of the measurement support floor

The measurement support floor consists of a 14 cm thick solid reinforced concrete slab (dimensions: see figure in annex 1). The standardised impact sound insulation is determined according to 1.

3. Determination of the standardised impact sound insulation of the floating floor construction

FLOATING FLOOR: The ''floating'' covering floor is installed on top of the measurement support floor betVJeen the raised edges of the measurement support floor, allowing as such to take into account the side contact insulation. FLOOR COVERINGS: These are placed in at Jeast 5, evenly spread places on the measurement floor. A description of the floor covering and its mounting on the measurement floor can be found in point 3 on page 2. The standardised impact sound insulation of the floating floor construction is determined according to Doint 1. The result is reoresented on oaae 4.

4. Determination of the impact noise level reduction by the floating covering floor (AL)

The impact noise level reduction represents the difference of the standardised impact sound insulation of the measurement support floor alone minus the standardised impact sound insulation of the total floor (support floor + covering). It is the best way to acoustically characterise the product tested. The results can be found on page 3.

5. Determination of the sound pressure level of the standardised impact sound Ln,r of a fictions, normalised reference support floor covered with the testconstruction

The standard EN ISO 717-2:1996 gives the pressure level range of the standardised impact sound Ln,r,O of a reference support floor. The calculated sound pressure level Ln,r of the standardised impact noise of the reference Hoar covered with the covering subjected to the lest is calculated from this value and the reduction of the noise level according to :

Ln,r = Ln,r,D .. AL

6. Single value indicators.

The single-value indicator (given by the index "vi') is described in the standard :

"EN /50 717-2:1996 Acoustics-Rating of sound insulation in buildings and of building elements - Part 2: Impact sound insulation (ISO 717-1:1996) " The calculation of the single-value indicator cannot be summarised in a few lines. See standard for details.

Old national single-value indicators (NL, B, FR) are also given in the annex to this report. Calculation modules and more information about the single-value indicator (and about acoustical standardisation in general) can be found on the website of the Acoustics laboratory, Le.:

http://WVv'W.bbrLbe/antenne norm

C.S.T.C. ---- 1 (J

<I: -I

W.T.C.B.

/' -',

~

test cells al BBR1, Umelette

Page 6: WTCB IfJ - Potichupotichu.cz/wp-content/uploads/2014/06/potichu-insulco-insulit-7-test... · N°DE,ATA,RE: DE 631xB063 N° Labo: AC5438 LABORATORY of ACOUSTICS TEST REPORT N° Test

80 Ln [dB]

70

60

50

40

30 C.S.T.C.

20 of I!. ~~ 10 t

It)

'" ~ 0

lPRODUCT TESTED:

insulit Bi+7

COMPANY: Insulee

F

0 It)

'"

Rue Suisson Aux Loups, 1A

0 0 0 0 0 0 0 0 It) r '"

0 0 0 ..

f [Hz]

BELGIUM: NBN 501400:1977 enteras de 1'lsolaUon acoustlque • Criteria van de akoestlsthe Isolatle

BEPALING VAN OE CATEGORIE

Hel mil dal de vloer tot een bapaalde celegatie bahoorl, wordt bepaald door de ligging van hel spectrum van hel door deze vlcer overgebrachte contaclgeluid Lo.v. de spectra, die de categorieen begrenzan. Wanneer het gemelen spectrum een of meer grensspectra snijdl, is hal de rigging van het ongunsligste deel van hat spectrum die de categone van de wand bepaaH. Nochtans, wanneer de Dverschrgdingen in de ongunslige zin (boven een grensspectrum) zoderng zijn del hun som in om hel even welke groep van 6 opeenvolgende lertsbanden I<:leiner is dan of gelijl<: aan 12 dB, dienl hiermee geen rel<:ening gehouden Ie worden.

DETERMINATION DE LA CATEGORIE l 'appartenance d'un plancher a une cah'igorie est determinee par la Situation du spectre des bruils de transmis par ce plancher par rapport aux speclres delimitant les categories. Dans Ie cas OU Ie spectre mesure chevauche un ou plusieurs spectres·limites, c'est la situation de la partiela plus defaVOfable dU spectre qui esl determinante pour Ie classement du plancheT. Touiefois, lorsque les depassemenis dans Ie sens defavorable(au-dessus d'un spectre·limlle) sontlels que leur addition dans n'importe quel groupe de 6 tierces successives esl inferieure a 12 dB, il n'en n'esl pas tenu compte pour Ie classement en categories.

Basic testfloor: Floating floor:

cat. cat. I a

NETHERLANDS: NEN 5079: mel 1989 Geluldwering Inwoongebouwen. Het weergeven In een getal van de geluldlsolatle van bouwclementen, gemeten In het laboralorium,

Basic festfToor:

Floating floor:

FRANCE

laboratorium-isolatie·index voor contactgeluid IcQ,llb = -6 dB

laboratorium-isolatie-index voor contactgeluid Ica,bob = 7 dB

a) NF S 31-062 (FlIvrler 1979) AcousUque • Mesure du pouvolr d'isolatioo acoustlque des elements de construction et de I'lsolement des Immeubles. Melliure en laboralolre de la transmlsllon du bruit de choc par lei planchers.

Basic testfloor: Floating floor:

Niveau Ln exprime en dB(A) = 82.5 dB(A)

Niveau In exprime en dB(A) = 55.9 dB(A)

bj NF 5 31-053 (F6vrler 1979) AcoUllique. Mesure du pouvolr d'isolatlon acoustlque des elements de construction et de I'lsolement des Immeubles, Mesure en laboratolre de la transmission du bruit de choc par les revetamenls de sol ella5 dalles flottantes·,

l'efficacite L\L exprimee en dB(A) = 25.8 dB(A)

"Note· measurement melhod based upon EN ISO 140 -6:1996: no supplementary weights have

upon the floor

GERMANY GREAT BRITAIN: the old national values are the same as the new EN

values In Ihls report

testfloor (based on spectrum (a)): Ln.o.w = 79.0 dB CI,o = -12 dB

+ floating floor (based on spectrum(b)): In.w = 51.0 dB CI = 1 dB

IReference floor (data (c) given in EN ISO 717-2) Ln.r.o.w = 78.0 dB C1,r.O = -11 dB

+ floating floor (calculated (c)-(a}+(b) ) Lnrw=52.0dB CII = idB

lRed~'ction of impact sound pre·ssure level

6lw= 78-ln,r,w= 26.0 dB

CI~\ = Cl.r,D· C I.r = -11 .9 dB

Page 7: WTCB IfJ - Potichupotichu.cz/wp-content/uploads/2014/06/potichu-insulco-insulit-7-test... · N°DE,ATA,RE: DE 631xB063 N° Labo: AC5438 LABORATORY of ACOUSTICS TEST REPORT N° Test