Upload
amaya-ricker
View
227
Download
0
Embed Size (px)
Citation preview
www.cpinmotion.dk
Reliability of Gait Deviation Index in children with spastic cerebral palsy
Helle Mätzke Rasmussen, Dennis B. Nielsen, Niels W. Pedersen, Søren Overgaard, Anders Holsgaard-Larsen
Department of Orthopaedic Surgery and Traumatology, Odense University Hospital, and Department of Clinical Research, University of Southern Denmark, Odense,
www.cpinmotion.dk
DisclosuresRelated to present study
– Grant from University of Southern Denmark (HMR); Odense University Hospital Research grants 2012 (AHL), the Region of Southern Denmark Research grants and Ph.D. Grants 2012 (AHL), the Physiotherapy Praxis Foundation (HMR), Ludvig and Sara Elsass Foundation (AHL) and The Danish Physiotherapy Research Fund 2013 (HMR).
– No conflicts of interest (DBN, NWP, SO)
Outside present study– Board memberships (Finalized): Eli Lilly Denmark, Advisory board: Fostero (SO); MSD:
Advisory board : NSAID (SO); Mundipharma International Ltd (SO)– Investigator (Finalized) Sanofi-aventis Denmark A/S (SO)– Principal Investigator (Currently) Eli Lilly (SO)– Grants to Institution: Biomet DK and Biomet Inc: DePuy and Protesekompaniet (SO);
Zimmer (SO, DBN, NWP, AHL, HMR)
www.cpinmotion.dk
3-diemensionel ganganalyse
Schwartz MH et al. (2008)
www.cpinmotion.dk
Gait Deviation IndexGDI Kinematic variablesPelvic X 3Hip x 3Knee x 1Foot x 2
100 Point = Reference group 10 Point = 1 SD
0°
20°
20°
Plan
tar /
Dor
sal fl
exio
n
Step 100%0%
www.cpinmotion.dk
Validity and reliability
Construct validity has previously been shown– FAQ, GMFCS, GMFM, GGI, CP Subtype
Reliability– Not investigated in children with CP
Schwartz MH et al. (2008), Molloy M et al. (2010), Massaad et al. (2013)
www.cpinmotion.dk
Materials
18 ChildrenSubtype10 Unilateral CP8 Bilateral CP
GMFCS9 GMFCS level I9 GMFCS level II
AgeAge 5 – 12 years Mean age 7.8 (SD 2.11)
www.cpinmotion.dk
Method TestTeam A
Retest
Laboratory Team B
Team C
+
Test Retest
+
Test Retest
+
www.cpinmotion.dk
Results - Bland-Altman plot
Mean – 0.3
SEM 95%
SEM 95%
www.cpinmotion.dk
Conclusion and perspective
Good reliability •Holds promise for the use of Gait Deviation Index as outcome measure in clinical research.
www.cpinmotion.dk
Thanks!
Lotte Slot JensenDennis Brandborg Nielsen
FundingOdense Universitets frie forskningsmidler 2012Region Syddanmarks Forskningspulje 2012 og Ph.d. pulje 2012Fysioterapi Praksis FondenLudvig og Sara Elsass FondDanske fysioterapeuters ForskningsfondSyddansk Universitet