X-RAY WorXThree Rivers Technical Conference August 3rd & 4th, 2010Elk River, MN
X-RAY WorX GmbHSiemensstraße 26D-30827 [email protected]://www.x-ray-worx.com
►Company Presentation►Microfocus X-Ray tube technology►Rod anode technology
X-RAY WorXCompany Presentation
X-RAY WorX GmbHSiemensstraße 26D-30827 [email protected]://www.x-ray-worx.com
Words of WelcomeAlfred Reinhold
… X-RAY WorX is a group of highly experienced and
competent experts, partly working in this business from the
very beginning of microfocus technology.
As the founder of the former company Feinfocus, that
introduced the first microfocus X-ray system for industrial
application with focal spot sizes below 5µm, I highly
appreciate the pioneering spirit of the young team of X-RAY
WorX…
Alfred Reinhold,
Pioneer of Microfocus X-ray Technology (February 2010)Source: http://www.alf-reinhold.de/
Vision
►Sole independent supplier of high resolution micro- and submicrofocus X-ray tubes
►Preferred supplier for OEMs and building up of long-term relationships
►Development of innovative microfocus technology
►Joint development with technical universities and scientific institutions
History
►February 2010: Foundation of X-RAY WorX by Thorsten Fröba and Holger Behnsen
►March 2010: First orders of OEM customers►March 2010: Finishing of the first high resolution
microfocus X-ray tube of the new XWT-series►June 2010: Presentation of 160kV rod anode on
ECNDT conference in Moscow►July 2010: Delivery of the first 160kV and 225kV
dual-head microfocus X-ray tube
The Founders
►Thorsten Fröba►15 years experience in the development of open
micro- and submicrofocus X-ray tubes►Excellent personal relationships to many prospective
OEM customers
►Holger Behnsen►8 years experience in international marketing and
sales of microfocus X-ray systems and tubes►Very trustful contact to OEMs, end customers and
local representatives
Organisation
► Thorsten Fröba, Technical GM (15)
► Andreas Kösterke, Production & QA (24)
► Benjamin Dostal, SW Development (5)
► Mario Fiedrich, HW Development (2)
► Holger Behnsen, Commercial GM (8)
► Dr. Jens Peter Steffen, Sales (4)
► Zoran Zecevic, Service & Training (10)
► Matthias Stoeber, Service & Training (2)
► Marc Fisker, Service & Sales Administration (3)
Altogether more than 73 years of experience in the business with microfocus X-ray tubes and systems
Fields of Business
X-RAY WorX Microfocus X-ray Technology
Development & Production Services
Microfocus X-ray tubes
Special X-ray tubes for CT
Rod anode tubes
Special projects OEM+R&D
Maintenance
Repair
Training
Used systems
Products
►Microfocus X-ray tubes 160/225kV►Transmission target►Reflection target►Exchangeable tube head
►High resolution submicrofocus tubes 80/100kV►Special targets►Special cathodes
►Special tubes for CT►Rod anode tubes
Microfocus tubes
XWT-160-T XWT-160-SEXWT-160-TC
XWT-225-T XWT-225-SEXWT-225-TC
Rod anode tubes
► Widespread application in ► Aerospace industry► Tank and pipeline construction► Casting industry
► NDT at inaccessible places► Engines► Hollow chamber profile elements► Pipes and tanks
► Different targets and beam geometries
► Exchangeable radiation heads
Summary
►Sole independent supplier of high resolution open micro- and submicrofocus X-ray tubes
►Concentration on core competence:Future development and production of X-ray tubes
►More than 73 years of experience in microfocus technology
►Worldwide sales & service
X-RAY WorXMicrofocus X-ray tube technologyX-RAY WorX GmbHSiemensstraße 26D-30827 [email protected]://www.x-ray-worx.com
Schematic view of a microfocus X-ray tube
►Cross section of a transmission X-Ray tube
HT-Flange
Tube hinge
HT-ReceptacleGrid cap RTU-Filament
Turbo pump
Vacuum gauge
Deflection unit
Objective coil
Objective aperture
Transmission target
Electron beam
Schematic view of a microfocus X-ray tube
►Centering of the electron beam
Insulated target
Target current [µA]
Centering current [mA]
Schematic view of a microfocus X-ray tube
►Cross section of an electron optic (reflexion) Solid target
Deflection unit
Objective coil
Objective aperture
Electron beam
Schematic view of a microfocus X-ray tube
►Tube head cooling
►High efficent cooling concept►Target direct cooling design►Two by-pass cooling channel►Two parallel cooling channel
Schematic view of a microfocus X-ray tube
►Tube head cooling
Cooling liquidinlet
Cooling liquidoutlet
Interaction electron - target
►Reflexion target – acc. voltage low
Electron beam :
Focus size / shape:
Interaction electron - target
►Reflexion target – acc. voltage high
Electron beam :
Focus size / shape:
Interaction electron - target
►Transmissiontarget
Electron beam :
Focus size / shape:
Target layer
Substrate layer
Low tube currentLow acc. voltage
High tube currentLow acc. voltage Electron beam focused
Interaction electron - target
►Transmissiontarget
Electron beam :
Focus size / shape:
Target layer
Substrate layer
Low tube currentHigh acc. voltage
High tube currentHigh acc. voltage Electron beam focused
Interaction electron - target
►Electron penetration depth
Penetration depth 12µm @ 100kV
- Tungsten
Penetration depth 20,5µm @ 100kV
- Cupper
►Spherical AberrationLens system
Focal length
Focal spot range
Focal plane
Spherical Aberration
Aperture
Resolution and dose rate
►Resolution and dose rate are depending on►Accelaration voltage►Tube current►Saturation of the filament current►Modulation of the electron beam►Material and thickness of the target layer►Aperture diameter – spherical aberration of the
electro-magnetic lens system►Design of the pole shoe (focal length)►and so on….
X-RAY WorXRod anode technology
X-RAY WorX GmbHSiemensstraße 26D-30827 [email protected]://www.x-ray-worx.com
Rod anode technology
► Widespread application in ► Aerospace industry► Tank and pipeline construction► Casting industry
► NDT at inaccessible places► Engines► Hollow chamber profile elements► Pipes and tanks
► Different targets and beam geometries
► Exchangeable radiation heads
Rod anode technology
►Target cooling with external cooling liquid feeding
►Inconvenient handling►Insufficient cooling of the O-Ring
sealing►Unstable vacuum during
continuous operation
►Standard rod anode
Rod anode technology
►Internal cooling channel►Effective cooling of the O-Ring
sealing up to 100W►Easy handling
►Rod anode with internal cooling
Rod anode technology
► External cooling► Limited penetration depth
► Internal cooling► Optimized usage of the
penetration depth
►Application advantage
►Application advantage
► Radiography of only one wall thickness
► Better localisation of material defects
► Better detail recognition
►Thank you for your attention
►Any questions?