12
X Series Centaurs In-grade ETL Listed Wet Label IP68 CX 2/14 79 Trenton Avenue Frenchtown, NJ 08825 Tel: (908) 996-7710 Fax: (908) 996-7042 www.designplan.com

X Series Centaur

Embed Size (px)

DESCRIPTION

Cast stainless steel in grade uplights for LED, Halogen and Metal Halide

Citation preview

Page 1: X Series Centaur

X Series CentaursIn-grade ETL Listed Wet Label IP68

CX 2/1479 Trenton Avenue Frenchtown, NJ 08825

Tel: (908) 996-7710 Fax: (908) 996-7042www.designplan.com

Page 2: X Series Centaur

C1X In-Ground LED FixtureIP68

. Cast stainless steel body 304 alloy

. 1W Cree XPE LED

. On-board electronics for 24V DC and 0-10V dimming. Unique “bottle cap” threaded lens frame. No screws to lose. Lens frame turned from solid stainless steel. 0.400” thick tempered glass lens. Walkover, drive over rated for 11,000 lbs at 30 mph. Cast stainless steel 304 alloy junction box. Silicone rubber anti siphon outlet box gasket . Remote power supply. Unit can be through wired for daisy chaining. Class II, not suitable for fountain or pool use.. Requires remote 24V Dc power supply . Available in RGB with remote DMX controller

listed wet label IP68

Series Lamp Wattage Body Color Temp. Optic Ballast Lens OptionsC1X L-LED 1L-1x1W 3000K LED

3L-1x1W 5000K LEDSS-Stainles Steel 0- None X-120vAC-24vDC T-CLR. Temp Glass 0-None4-Fully recessed

w/cond. entries 1- 6 Degree Spot Remote Driver2- 25 Degree Flood

K-Internally Ceramic CoatedTempered Glass

G-Frosted Toughened GlassNote: Other color available

Note: LED Optics are for use with 'T' clear glass lens.They are not intended for 'K' or 'G' Lenes

Note: On board 0-10v Dimming

SERIES DRIVER PART # DESCRIPTION WATTAGE UNITS POWERED SPECIAL DETAILS

C1X PPLT00155 120VAC-24VDC 30W 1 to 24 parallelPPLT00157 120VAC-24VDC 60W 1 to 48 parallelPPLT00158 120VAC-24VDC 100W

1W 24vDC w/ integral 0-10v dim1W 24vDC w/ integral 0-10v dim1W 24vDC w/ integral 0-10v dim 1 to 80 parallel

Power Supplies

Designplan | L&L Luce&Light

Designplan Lighting

Page 3: X Series Centaur

Staten Island 911 Memorial Lighting Consultant: Fisher, Marantz, Stone Fixture: C1X

Designplan | L&L Luce&Light

Designplan Lighting

Page 4: X Series Centaur

C2X In-Ground 24V Dimmable LED Fixture

IP68 Remote Driver

. Cast stainless steel body 304 alloy

. 1W Cree XPE LED

. On board electronics for 24V DC and 0-10V Dimming. Unique “bottle cap” threaded lens frame. No screws to lose. Lens frame turned from solid stainless steel. 0.400” thick tempered glass lens. Walkover, drive over rated for 11,000 lbs at 30 mph. Cast stainless steel 304 alloy junction box. Silicone rubber anti siphon outlet box gasket . Remote power supply. Unit can be through wired for daisy chaining . Class II, not suitable for fountain or pool use. . Requires remote 24V Dc power supply. Available in RGB with remote DMX controller

listed wet label IP68

Series Lamp Wattage Body Finish Ballast OptionsC2X L-LED 1L-1x1W 3000K LED

2L-1x1W 4000K LED4L-1x3W 3000K LED5L-1x3W 4000K LED

SS-Stainless Steel X-Remote 24vDC 0-None4-Fully recessed w/cond. entries Transformer

Required

LensT-Clear Temp GlassK-Internally Ceramic CoatedG-Frosted Tempered Glass

Optic0- None1- 10 Degree Narrow2- 21 Degree Medium3- 39 Degree Wide4- 10x44 Degree Elliptical

Note: Other colors available on requestNote: LED Optics are for use with 'T' clear glass lens.They are not intended for 'K' or 'G' Lenes

Note: On board 0-10v Dimming

Power SuppliesC2X PPLT00155 120VAC-24VDC 30W 1 to 10 parallel1 LED/UNIT 1 to 6 parallel

PPLT00157 120VAC-24VDC 60W 1 to 19 parallel1 to 13 parallel

PPLT00158 120VAC-24VDC 100W 1 to 32 parallel

1W 24vDC w/ integral 0-10v dim3w 24vDC w/ integral 0-10v dim1W 24vDC w/ integral 0-10v dim3w 24vDC w/ integral 0-10v dim1W 24vDC w/ integral 0-10v dim3w 24vDC w/ integral 0-10v dim 1 to 22 parallel

Designplan Lighting

Page 5: X Series Centaur

C4X In-Ground 24V Dimmable LEDIP68 Remote Driver

. Cast stainless steel body 304 alloy

. 3x 3W Cree XPE LED

. On board electronics for 24V DC and 0-10V dimming. Unique “bottle cap” threaded lens frame. No screws to lose. Lens frame turned from solid stainless steel. 0.400” thick tempered glass lens. Walkover, drive over rated for 11,000 lbs at 30 mph. Cast stainless steel 304 alloy junction box . Silicone rubber anti siphon outlet box gasket . Remote power supply. Unit can be through wired for daisy chaining . Class II. Requires remote power supply

listed wet label IP68

Series Lamp Wattage Body Finish Optic Ballast OptionsC4X L-LED 4-Fully recessed

w/cond. entriesSS-Stainless Steel 0- None Q-Remote 24vDC 0-None

1- Narrow (6°) Driver Required

LensT-Clear Temp GlassJ-Flash White BTM &

3- Wide (25°) (Int. 0-10V Dim.)

1R-3x1W White 3000K2R-3x1W White 4000K3R-3x3W White 3000K4R-3x3W White 4000K 4- Elliptical (6°x25°)

Non-Skid Top PatternK-Flash White BTM &

Remote Driver Clear Top

G-Internally FrostedOther colors availableupon request to be ordered

separately Toughened Glass

Q-Non-Skid Top PatternedTempered Glass

Power Supplies

C4X PPLT00155 120VAC-24VDC 30W 1 to 6 parallel1 to 2 parallel

3 LED'S PER PPLT00157 120VAC-24VDC 60W 1 to 13 parallelUNIT 1 to 5 parallel

PPLT00158 120VAC-24VDC 100W 1 to 22 parallel

1W 24vDC w/ integral 0-10v dim3w 24vDC w/ integral 0-10v dim1W 24vDC w/ integral 0-10v dim3w 24vDC w/ integral 0-10v dim1W 24vDC w/ integral 0-10v dim3w 24vDC w/ integral 0-10v dim 1 to 8 parallel

Designplan Lighting

Page 6: X Series Centaur

C4C In-Ground LED Fixture

IP68 Remote Integral Driver

. Cast stainless steel body 304 alloy

. Cree MCE LED

. On board 24vDC with DMX interface individually controlled. Unique “bottle cap” threaded lens frame. No screws to lose. Lens frame turned from solid stainless steel. 0.400” thick tempered glass lens. Walkover, drive over rated for 11,000 lbs at 30 mph. Cast stainless steel 304 alloy junction box . Silicone rubber anti siphon outlet box gasket . Remote power supply. Unit can be through wired for daisy chaining . Class II, not suitable for fountain or pool use . Available anti slip dot pattern glass lens. DMX channels are not field addressable without specialized equipment. If addresses are not specified, the fixture will default to address 1 (1-red, 2-green, 3-blue, 4-white).

listed wet label IP68

Series Lamp Wattage Body Finish Optic Ballast OptionsC4C L-LED 4-Fully recessed

w/cond. entriesSS-Stainless Steel 0- None X-Remote 24vDC 0-None3K-5W RGBW LED

4K-5W Dynamic White 1- Narrow (10°) Power Supply Req'd

LensT-Clear Temp GlassJ-Flash White BTM &

2- Med (30°) (INT DMX INTERFACE) Non-Skid Top PatternK-Flash White BTM &

Clear TopG-Internally Frosted

Toughened GlassQ-Non-Skid Top Patterned

Tempered Glass

Note: Integral 24vDC Driver Board along with individually controlled DMX interface

C4C PPLT00155 1 to 4 parallel1 CREE MCE PPLT00157 1 to 9 parallel

per unit PPLT00158

120VAC-24VDC30W 120VAC-24VDC 60W120VAC-24VDC 100W

4.6w 24vDC w/ int. DMX interface4.6w 24vDC w/ int. DMX interface4.6w 24vDC w/ int. DMX interface 1 to 16 Parallel

Power Supplies

To be used with Remote Power Supply.

Designplan Lighting

Page 7: X Series Centaur

C7X In-Ground FixtureFlat Trim IP68

. Cast stainless steel body 304 alloy

. 6x 1W Cree XPE LED

. Integral power supply for 120V non-dimming

. Available in MR16 12V DC halogen with integral power supply. Unique “bottle cap” threaded lens frame. No screws to lose. Lens frame turned from solid stainless steel. 0.400” thick tempered glass lens. Walkover, drive over rated for 11,000 lbs at 30 mph. Cast stainless steel 304 alloy junction box . Silicone rubber anti siphon outlet box gasket . Remote power supply. Unit can be through wired for daisy chaining . Class I. Available anti slip dot pattern glass lens

Series Lamp Wattage Body Finish Grill Ballast OptionsC7X 6-Halogen 14-37W MR16 NSP10 4-Fully recessed

w/cond. entriesSS-Stainless Steel 1- STD T-120V-12V Elect.

LensG-Internally Frosted 0-None

15-37W MR16 NSP25 Integral Trans.16-37W MR16 FL40 J-277V-12V Elect.

Integral Trans.

Toughened GlassU-Non Skid Temp GlassT-Clear Temp Glass

C-120V-277V Elect.Integral Trans.

1F-1Wx6 Ring 3K White LEDAM-1Wx6 Ring 5K White LED2F-1Wx6 Ring Red LED3F-1Wx6 Ring Blue LED4F-1Wx6 Ring Green LED5F-1Wx6 Ring Cyan LED6F-1Wx6 Ring Amber LEDAG-20W MH GE MR16 Spot 3000K AH-20W MH GE MR16 Flood 3000K

listed wet label IP68

Note: MR16 Lamps mounted to adjustable swivel bracket tilt max 15° off vertical. Note:

Halogen is either T or J. LED is always C and comes standard with 0-10V dimming. HID metal halide is always C.

L-LED9-HID

79 Trenton Avenue Frenchtown, NJ 08825

Tel: (908) 996-7710 Fax: (908) 996-7042

79 Trenton Avenue Frenchtown, NJ 08825

Tel: (908) 996-7710 Fax: (908) 996-7042

Designplan Lighting

Page 8: X Series Centaur

CDX In-Ground Fixture

Flat Trim IP68

. Cast stainless steel body 304 alloy

. Xicato 1300lm LED module with integral driver for 120-277V w/ 0-10V Dimming or . 20W MR16 MH adjustable with integral ballast. Unique “bottle cap” threaded lens frame. No screws to lose. Lens frame turned from solid stainless steel . 0.400” thick tempered glass lens. Walkover, drive over rated for 11,000 lbs at 30 mph. Unit can be through wired for daisy chaining . Class I. Available anti slip dot pattern glass lens

Series Lamp Wattage Body Finish Grill Ballast OptionsCDX 9-HID 4-Fully recessed

w/cond. entriesSS-Stainless Steel 1- STD C-120-277V Integral 0-None

L-LED Electronic

LensT-Clear Temp GlassQ-Non Skid Temp Glass W-Linear Spread

L-120-277V w/ Integral Patterened Q-Honeycomb

AG-20W MH GE MR16 Spot 3000KAH-20W MH GE MR16 Flood 3000KFB-39W MH GE MR16 Spot 3000KFC-39W MH GE MR16 Flood 3000K 0-10V Dimming Louver

S-Solite LensBallast 'C' HID Only B-Special Lens

EX-1300lm Xicato 3000KEY-1300lm Xicato 3500KEZ-1300lm Xicato 4000K Ballast 'L' LED Only (see drawing)

Note: Options AG, AH, FB, FC HID Only EX, EY, EZ LED Only added to rubber

holder.

listed wet label IP68

Designplan Lighting

Page 9: X Series Centaur

DrawingsC1X

C2X

Designplan Lighting

Page 10: X Series Centaur

Drawings

C4X

Designplan Lighting

C4C

Page 11: X Series Centaur

DrawingsC7X

CDX - LED

Designplan Lighting

Page 12: X Series Centaur

DESIGNPLAN LIGHTING, INC., 79 TRENTON AVE, FRENCHTOWN, NJ 08825 T. 908-996-7710 F. 908-996-7042

General Installation Instructions11/2/07

FAILURE TO FOLLOW THESE INSTRUCTIONS WILL VOID WARRANTY

RISK OF ELECTRICAL SHOCK. THIS EQUIPMENT IS TO BE INSTALLED BY A QUALIFIED ELECTRICIAN ONLY. MAKE CERTAIN ELECTRICAL SUPPLY CIRCUIT IS DE-ENERGIZEDBEFORE BEGINNING INSTALLATION. CHECK FIXTURE LABEL FOR CORRECT VOLTAGE.READ ALL INSTRUCTIONS CAREFULLY.

LOCATION

This model is designed for concrete pour installation. The upper edge of the housing must be flush with the prepared surface into which it is recessed. Do not install fixture in a manner that creates a pocket where water can sit on top of fixture.

Not suitable for use in places where the luminaire is likely to be exposed to a horizontal stress load caused by braking,acceleration or change of direction.

INSTALLATION

1. Lighting fixture comes fully assembled. Note: When not working on fixture replace trim ring for site safety and to protect fixture components from moisture and damage. Keep each trim ring with the original body it was supplied on.Note: Use care to protect O-ring on trim ring. Do not remove, loosen, cut, deform or otherwise disturb O-ring. Keep O-ring clean and dry.

2. Set fixture in desired location. Position the fixture in such a manner that the conduit/cable is not stressed at the entry point to the light fixture.

3. The foundation on which the luminaire is to be installed must correspond to the maximum permissible pressure load of the luminaire. Suitable drainage must also be provided. Level the body in two horizontal planes using the three leveling tabs around outer body. The upper edge of the housing must be flush with the prepared surface into which it is recessed.UNDER NO CIRCUMSTANCES MAY IT BE LOWER!

4. Unthread lens assembly from body with tool provided. Ensure that all internal surfaces of the fixture are keptcompletely dry during installation. Pry out the accessory gasket by using a screw driver. Carefully by hand remove reflector.

5. Connect incoming leads to quick disconnect plug. GREEN WIRE TO “GROUND”, CONNECT BLACK FIXTURE TO BLACK BUIDLING WIRE AND CONNECT WHITE FIXTURE WIRE TO WHITE BUILDING WIRE. Replacetray, lamp, and reflector. Make sure that no wires have been damaged.

6. If using conduit entries, the entries must be sealed with “Dap Heavy Duty Kwik Foam” (not provided). The foam should be sprayed from inside the fixture up into the conduit. Failure by the contractor to use the DAP product could cause a void in the warranty. Replace tray with lamping. If not using through wiring, plug second conduit entry with 3/4"conduit plug. Please make sure wet label requirements are meet.

7. Install lamp and adjust if necessary. Tighten all screws to assure the lamp will not shift after aiming is acquired.Replace reflector and accessory gasket.

8. Place lens frame over fixture ensuring that there is no foreign matter between the lens frame and the body. Start thelamp and bring luminaire to operating temperature (20 to 30min.), this will evaporate the moisture content of air tobe trapped. Once operating temperature has been reached, carefully thread the trim assembly to body with tool provided.

79 Trenton Avenue Frenchtown, NJ 08825

Tel: (908) 996-7710 Fax: (908) 996-7042www.designplan.com