5911 Butterfield Road Hillside, IL 60162 • tel: (708) 236-6000 • fax: (708) 236-6006 [email protected] • www.ljtechnologies.com • ISO 9001 Registered Rev: 9431X-3A 1 94311/94312/94313/94314 Detonation Flame Arresters Features Withstands instantaneous pressure at the Flame front in excess of 500 psig Tube bank design ensures consistent functioning Carbon steel or 316 S.S. housing construction, 316 S.S. tube bank Optional fittings for pressure taps or temperature probes Designed & tested in accordance with appendix A, 33 U.S. Code of Federal Regulations part 154 Standard drain plug Pressure and temperature taps optional The Shand & Jurs Detonation Flame Arresters provide protection against flame propagation through piping runs and vapor recovery systems, while allowing maximum flow efficiencies. This design quenches a flame front approaching from either direction, even if it has transitioned to a detonation. The Arresters contain a detonation while retaining the integrity of both the arresting element and the housing. This is ensured by the design of the passages in the tube bank and the detonation resistant construction. Standard construction of the housing is available in Carbon Steel or 316 Stainless Steel. The tube bank is Stainless Steel throughout. Special construction materials to withstand the corrosive actions of some vapors and atmospheric conditions are available upon request. Because of the severe service conditions that the Detonation Flame Arrester encounters, all construction welding is performed in accordance with ASME Boiler and Pressure Vessel Code Section Vlll and IX. Class 150lb. hydrostatically tested at 425 psig. Class 300lb. hydrostatically tested at 750 psig. These models are available in a range of sizes from 2” through 24”. Additional sizes available upon request. Standard connections are ANSI 150lb. or 300lb. Class raised face flanges. 9431X Detonation Flame Arresters Model Number Service / Approval* Size 94311 NEC Group D / Factory Mutual 2” - 12” 94312 NEC Group D Marine / Factory Mutual, U.S. Coast Guard 2” - 12” 94313 NEC Group C & D / Factory Mutual 2” - 6” 94314 NEC Group C & D Marine / Factory Mutual 2” - 6” *STEEL, 316, DUPLEX Stainless Steel

XDD DFFFF2 5HY˛˝ ; $ 1ipcmty.com/wp-content/uploads/2015/07/94311-3A.pdf · 2015. 7. 30. · XDD DFFFF2 5HY˛˝ ; $ Detonation Flame Arresters 2 94311/94312/94313/94314 Class 300

  • Upload
    others

  • View
    7

  • Download
    0

Embed Size (px)

Citation preview

Page 1: XDD DFFFF2 5HY˛˝ ; $ 1ipcmty.com/wp-content/uploads/2015/07/94311-3A.pdf · 2015. 7. 30. · XDD DFFFF2 5HY˛˝ ; $ Detonation Flame Arresters 2 94311/94312/94313/94314 Class 300

5911 Butterfield Road Hillside, IL 60162 • tel: (708) 236-6000 • fax: (708) [email protected] • www.ljtechnologies.com • ISO 9001 Registered Rev: 9431X-3A

1

94311/94312/94313/94314Detonation Flame Arresters

Features • Withstands instantaneouspressure

attheFlamefrontinexcessof500psig

• Tubebankdesignensuresconsistentfunctioning

• Carbon steel or 316 S.S. housingconstruction,316S.S.tubebank

• Optionalfittingsforpressuretapsortemperatureprobes

• Designed&testedinaccordancewithappendixA, 33U.S.CodeofFederalRegulationspart154

• Standarddrainplug

• Pressure and temperature tapsoptional

TheShand&JursDetonationFlameArrestersprovideprotectionagainstflamepropagationthroughpipingruns and vapor recovery systems,while allowingmaximumflowefficiencies. Thisdesignquenchesaflamefrontapproachingfromeitherdirection,evenifithastransitionedtoadetonation.TheArresterscontainadetonationwhileretainingtheintegrityofboththearrestingelementandthehousing.Thisisensuredbythedesignofthepassagesinthetubebankandthedetonationresistantconstruction.

Standardconstructionof thehousing isavailable inCarbon Steelor 316 Stainless Steel. The tubebankis Stainless Steel throughout. Special constructionmaterialstowithstandthecorrosiveactionsofsomevapors andatmospheric conditionsareavailableuponrequest.

Becauseof the severe serviceconditions that theDetonationFlameArresterencounters,allconstructionweldingisperformedinaccordancewithASMEBoilerandPressureVesselCodeSectionVllland IX.Class150lb.hydrostaticallytestedat425psig.Class300lb.hydrostaticallytestedat750psig.

Thesemodelsareavailableinarangeofsizesfrom2”through24”.Additionalsizesavailableuponrequest.StandardconnectionsareANSI150lb.or300lb.Classraisedfaceflanges.

9431X Detonation Flame Arresters

Model Number Service / Approval* Size

94311 NECGroupD/FactoryMutual 2”-12”

94312 NECGroupDMarine/FactoryMutual,U.S.CoastGuard 2”-12”

94313 NECGroupC&D/FactoryMutual 2”-6”

94314 NECGroupC&DMarine/FactoryMutual 2”-6”

*STEEL,316,DUPLEXStainlessSteel

Page 2: XDD DFFFF2 5HY˛˝ ; $ 1ipcmty.com/wp-content/uploads/2015/07/94311-3A.pdf · 2015. 7. 30. · XDD DFFFF2 5HY˛˝ ; $ Detonation Flame Arresters 2 94311/94312/94313/94314 Class 300

5911 Butterfield Road Hillside, IL 60162 • tel: (708) 236-6000 • fax: (708) [email protected] • www.ljtechnologies.com • ISO 9001 Registered Rev: 9431X-3A

Detonation Flame Arresters

2

94311/94312/94313/94314

Class 300 lb.

Class 150 lb.

Dimensions

Size 2” 3” 4” 6” 8” 10” 12” 18”“A” 305/16 351/16 379/16 451/16 605/16 749/16 761/16 6913/16“B” 61/2 81/4 10 121/2 15 171/2 201/2 28“C” 10 121/2 15 201/2 251/2 301/2 36 471/2

Size 2” 3” 4” 6” 8” 10” 12” 14” 16” 18”“A” 291/16 339/16 361/16 431/16 581/16 7115/16 739/16 595/16 595/16 6113/16“B” 6 71/2 9 11 131/2 16 19 21 231/2 25“C” 9 11 131/2 19 231/2 271/2 32 383/4 383/4 433/4

Alldesignssubjecttochange.Certifieddimensionsandspecificationsavailableuponrequest.

Specifications

Materials of Construction

Sizes:2”,3”,4”,6”,8”,10”,12”,14”,16”,18”,20”,22”,24”DINSizesAvailable

CarbonSteel,316StainlessSteel,Carpenter20,Hastelloy-C,orDuplexStainlessSteel.(OtherMaterialAvailable)

150/300 lb.