Part Number 900-783-R Revision B December 2017

xPico 110 Wired Device Server Module

User Guide

Page 2: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

xPico® 110 Wired Device Server Module User Guide 2

Intellectual Property

© 2017 Lantronix. All rights reserved. No part of the contents of this publication may be transmitted or reproduced in any form or by any means without the written permission of Lantronix.

Lantronix and xPico are registered trademarks, and DeviceInstaller is a trademark of Lantronix in the United States and other countries. DeviceInstaller is a trademark of Lantronix, Inc.

Patented: http://patents.lantronix.com; additional patents pending.

Ethernet is a trademark of XEROX Corporation. UNIX is a registered trademark of the Open Group. Windows is a trademark of Microsoft Corp.

Warranty

For details on the Lantronix warranty policy, please go to our Web site at www.lantronix.com/support/warranty.

Contacts

Lantronix Corporate Headquarters

7535 Irvine Center Drive Suite 100 Irvine, CA 92618, USA

Toll Free: 800-526-8766 Phone: 949-453-3990 Fax: 949-453-3995

Technical Support Online: www.lantronix.com/support

Sales Offices For a current list of our domestic and international sales offices, go to the Lantronix web site at www.lantronix.com/about/contact

Disclaimer

Operation of this equipment in a residential area is likely to cause interference, in which case the user, at his or her own expense, will be required to take whatever measures may be required to correct the interference.

Note: This product has been designed to comply with the limits for a Class B digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with this guide, may cause harmful interference to radio communications.

Page 3: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

xPico® 110 Wired Device Server Module User Guide 3

Changes or modifications to this device not explicitly approved by Lantronix will void the user's authority to operate this device.

Note: With the purchase of xPico 110 wired device server module, the OEM agrees to an OEM firmware license agreement that grants the OEM a non-exclusive, royalty-free firmware license to use and distribute the binary firmware image provided, only to the extent necessary to use the xPico hardware. For further details, please see the xPico OEM firmware license agreement.

Revision History Date Rev. Comments

March 2017 A Initial release for firmware version 6.11.0.5.

December 2017 B Updated enhanced password information.

For the latest revision of this product document, please check our online documentation at www.lantronix.com/support/documentation.

Page 4: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

List of Tables and Figures

xPico® 110 Wired Device Server Module User Guide 4

Table of Contents

Intellectual Property __________________________________________________ 2

Warranty ___________________________________________________________ 2

Contacts ___________________________________________________________ 2

Disclaimer __________________________________________________________ 2

Revision History _____________________________________________________ 3 List of Tables ________________________________________________________ 8

List of Figures _______________________________________________________ 9

1. Using This Guide 10

Purpose and Audience _______________________________________________ 10

Chapter Summary ___________________________________________________ 10 Additional Documentation _____________________________________________ 11

2. Introduction 12

Capabilities ________________________________________________________ 12

Applications ________________________________________________________ 12 Protocol Support ____________________________________________________ 13

Configuration Methods _______________________________________________ 13

Addresses and Port Numbers __________________________________________ 13

Hardware Address _______________________________________________ 13

IP Address _____________________________________________________ 14

Port Numbers ___________________________________________________ 14 Product Information Label _____________________________________________ 14

3. Using DeviceInstaller 15

Installing DeviceInstaller ______________________________________________ 15

Assigning an IP Address ______________________________________________ 15 Accessing the xPico 110 Wired Device Server Module Using DeviceInstaller _____ 16

Viewing the Current Configuration ______________________________________ 16

4. Configuration Using Web Manager 19

Accessing Web Manager Using DeviceInstaller ____________________________ 19

Network Configuration _______________________________________________ 21

Page 5: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

Table of Contents

xPico® 110 Wired Device Server Module User Guide 5

Network Mode __________________________________________________ 21

Automatic IP Address Configuration _________________________________ 21

Static IP Address Configuration _____________________________________ 22 Ethernet Configuration ____________________________________________ 23

Server Configuration _________________________________________________ 24

Server Configuration ______________________________________________ 24

Advanced ______________________________________________________ 25

Host List Configuration _______________________________________________ 25

Retry Settings ___________________________________________________ 26 Host Information _________________________________________________ 26

Channel 1 and 2 Configuration _________________________________________ 27

Serial Settings __________________________________________________ 27

Connection Settings - TCP _________________________________________ 30

Connection Settings - UDP_________________________________________ 33

Configurable Pin Settings _____________________________________________ 34 Configurable Pin Functions ________________________________________ 35

Apply Settings ______________________________________________________ 35

Apply Defaults ______________________________________________________ 35

5. Configuration via Telnet or Serial Port (Setup Mode) 37

Accessing Setup Mode _______________________________________________ 37

Telnet Connection _______________________________________________ 37

Serial Port Connection ____________________________________________ 39

Exiting Setup Mode __________________________________________________ 39

6. Setup Mode: Server Configuration 40

Server Configuration (Option 0) ________________________________________ 40

IP Address _________________________________________________________ 40

Set Gateway IP Address ______________________________________________ 41

Netmask: Number of Bits for Host Part ___________________________________ 41

Set DNS Server IP Address ___________________________________________ 41

Change Telnet/Web Manager Password _________________________________ 42 DHCP Name _______________________________________________________ 42

7. Setup Mode: Channel Configuration 43

Channel 1 (Option 1) or Channel 2 (Option 2) _____________________________ 43

Page 6: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

Table of Contents

xPico® 110 Wired Device Server Module User Guide 6

Baudrate __________________________________________________________ 43

I/F (Interface) Mode__________________________________________________ 44

Flow ______________________________________________________________ 44 Port Number _______________________________________________________ 45

Connect Mode ______________________________________________________ 45

a) Incoming Connection ___________________________________________ 46

b) Response ____________________________________________________ 47

c) Active Startup _________________________________________________ 47

d) Datagram Type ________________________________________________ 50 e) Modem Mode _________________________________________________ 50

Send the Escape Sequence (+++) in Modem Mode _________________________ 53

Show IP addr after 'RING' _____________________________________________ 53

Auto Increment Source Port ___________________________________________ 53

Remote IP Address __________________________________________________ 53

Remote Port _______________________________________________________ 53 DisConnMode ______________________________________________________ 54

Flush Mode (Buffer Flushing) __________________________________________ 55

Pack Control _______________________________________________________ 55

Packing Interval _________________________________________________ 56

Trailing Characters _______________________________________________ 56

Send Characters _________________________________________________ 56 DisConnTime (Inactivity Timeout) _______________________________________ 57

Send Characters ____________________________________________________ 57

Telnet Terminal Type ________________________________________________ 57

Channel (Port) Password _____________________________________________ 57

8. Setup Mode: Advanced Settings 58

Expert Settings (Option 5) _____________________________________________ 58

TCP Keepalive time in seconds _____________________________________ 59

ARP Cache timeout in seconds _____________________________________ 59

CPU Performance _______________________________________________ 59

Disable Monitor Mode at bootup ____________________________________ 59 HTTP Port Number _______________________________________________ 59

MTU Size ______________________________________________________ 60

TCP Re-Transmission Timeout _____________________________________ 60

Enable alternate MAC ____________________________________________ 60

Ethernet Connection Type _________________________________________ 60

Page 7: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

Table of Contents

xPico® 110 Wired Device Server Module User Guide 7

Security Settings (Option 6) ___________________________________________ 60

Disable SNMP __________________________________________________ 61

SNMP Community Name __________________________________________ 61 Disable Telnet Setup _____________________________________________ 61

Disable TFTP Firmware Upgrade ____________________________________ 61

Disable Port 77FE (Hex) ___________________________________________ 62

77FEh Access Mode _____________________________________________ 62

Disable Web Server ______________________________________________ 62

Disable Web Setup _______________________________________________ 62 Disable ECHO Ports ______________________________________________ 62

Enable Encryption _______________________________________________ 63

Enable Enhanced Password _______________________________________ 64

Disable Port 77F0 (Hex) ___________________________________________ 64

Default Settings (Option 7) ____________________________________________ 64

Channel 1 and Channel 2 Configuration Defaults _______________________ 64 Expert Settings Defaults ___________________________________________ 65

Security Settings Defaults _________________________________________ 65

9. GPIO Interface 66

Configurable Pins ___________________________________________________ 66 Features _______________________________________________________ 66

Control Protocol ____________________________________________________ 67

Guidelines ______________________________________________________ 67

Commands _____________________________________________________ 67

Examples _________________________________________________________ 70

10. Firmware Upgrades 71

Obtaining Firmware __________________________________________________ 71

Reloading Firmware _________________________________________________ 71

Using TFTP: Graphical User Interface ________________________________ 71

Using TFTP: Command Line Interface ________________________________ 72

Recovering the Firmware Using the Serial Port and DeviceInstaller _________ 73

11. Monitor Mode 74

Entering Monitor Mode Using the Serial Port ______________________________ 74

Entering Monitor Mode Using the Network Port ____________________________ 74

Page 8: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

Table of Contents

xPico® 110 Wired Device Server Module User Guide 8

Monitor Mode Commands _________________________________________ 74

12. Troubleshooting 77

Problems and Error Messages _________________________________________ 77

A: Technical Support 80

B: Binary to Hexadecimal Conversions 81

Converting Binary to Hexadecimal ______________________________________ 81

Conversion Table ________________________________________________ 81

Scientific Calculator ______________________________________________ 81

C: Compliance 83

RoHS, REACH and WEEE Compliance Statement _________________________ 83

List of Tables

Table 6-1. BootP/DHCP/AutoIP Options _________________________________ 40

Table 6-2. Standard IP Network Netmasks _______________________________ 41 Table 7-1. Interface Mode Options ______________________________________ 44

Table 7-2. RS232 Interface Mode Settings ________________________________ 44

Table 7-3. Flow Control Options ________________________________________ 45

Table 7-4. Reserved Port Numbers _____________________________________ 45

Table 7-5. Connect Mode Options ______________________________________ 46 Table 7-6. Manual Connection Address Example __________________________ 48

Table 7-7. Modem Mode Messages _____________________________________ 51

Table 7-8. Modem Mode Commands ____________________________________ 52

Table 7-9. Disconnect Mode Options ____________________________________ 54

Table 7-10. Flush Mode Options ________________________________________ 55

Table 7-11. Pack Control Options _______________________________________ 56 Table 10-1. Firmware Files ____________________________________________ 71

Table 11-1. Monitor Mode Commands ___________________________________ 75

Table 11-2. Command Response Codes _________________________________ 76

Page 9: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

Table of Contents

xPico® 110 Wired Device Server Module User Guide 9

List of Figures

Figure 2-1. Product Label _____________________________________________ 14

Figure 4-1. Web Manager Login Window _________________________________ 20

Figure 4-2. Lantronix Web Manager _____________________________________ 20

Figure 4-3. Network Settings __________________________________________ 21

Figure 4-4. Server Settings ____________________________________________ 24 Figure 4-5. Hostlist Settings ___________________________________________ 26

Figure 4-6. Channel Serial Settings _____________________________________ 27

Figure 4-7. TCP Connection Settings ____________________________________ 30

Figure 4-8. UDP Connection Settings ____________________________________ 33

Figure 4-9. Configurable Pins Settings ___________________________________ 34

Figure 4-10. Apply Settings and Apply Defaults ____________________________ 36 Figure 5-1. xPico 110 Address _________________________________________ 38

Figure 5-2. Setup Menu Options ________________________________________ 38

Figure 7-1. Serial Port Parameters ______________________________________ 43

Figure 7-2. Hostlist Option ____________________________________________ 49

Figure 8-1. Expert Settings ____________________________________________ 58

Figure 8-2. Security Settings ___________________________________________ 60 Figure 10-1. TFTP Window ____________________________________________ 72

Page 10: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

xPico® 110 Wired Device Server Module User Guide 10

1. Using This Guide

Purpose and Audience

This guide covers the xPico® 110 wired device server module. It provides the information needed to configure, use, and update the xPico 110 firmware and is intended for OEMs and system integrators who are embedding the xPico 110 wired device server module in their product designs.

Chapter Summary

Document Description

2: Introduction Describes the main features of the xPico 110 wired device server module and the protocols it supports.

3: Using DeviceInstaller Provides information for getting your unit up and running, using DeviceInstaller to assign an IP address.

4: Configuration Using Web Manager

Details using the Web Manager to set parameters such as port and server properties.

5: Configuration via Telnet or Serial Port (Setup Mode)

Provides instructions for accessing Setup Mode (command line interface) using a Telnet connection through the network or a terminal or terminal emulation program through the serial port.

6: Setup Mode: Server Configuration

Details the network (server) settings.

7: Setup Mode: Channel Configuration

Details the serial port settings.

8: Setup Mode: Advanced Settings

Details expert and security settings and explains how to reset the unit to factory default values.

9: GPIO Interface Provides instructions for configuring the 8 General Purpose I/O pins (CP1-8).

10: Firmware Upgrades Provides instructions for obtaining the latest firmware and updating the xPico 110 wired device server module.

11: Monitor Mode Provides instructions for accessing and using the command line interface for monitoring the network and diagnosing problems.

12: Troubleshooting Describes common problems and error messages and how to contact Lantronix Technical Support.

A: Technical Support Provides contact information for Lantronix and other technical support options.

B: Binary to Hexadecimal Conversions

Provides instructions for converting binary numbers to hexadecimals.

C: Compliance Provides compliance information.

Page 11: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

1: Using This Guide

xPico® 110 Wired Device Server Module User Guide 11

Additional Documentation

Visit the Lantronix Web site at www.lantronix.com/support/documentation for the latest documentation and the following additional documentation.

Document Description xPico 110 Wired Device Server Module Integration Guide

Provides information about the xPico 110hardware, testing the xPico 110 wired device server module using the evaluation board, and integrating the xPico 110 unit into your product.

xPico 110 Evaluation Kit Quick Start

Instructions for using the xPico 110 wired device server module on the xPico evaluation kit.

xPico 110 Evaluation Kit User Guide

Information needed to use the xPico 110 wired device server on the evaluation kit.

Com Port Redirector User Guide Provides information on using the Windows® utility to create a virtual com port.

DeviceInstaller Online Help Provides information on using DeviceInstaller™ application to configure IP addresses and locate Lantronix devices on the network.

Page 12: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

xPico® 110 Wired Device Server Module User Guide 12

2. Introduction This chapter summarizes the xPico 110 wired device server module’s features and the basic information needed to get started.

Capabilities

The xPico 110 wired device server module has the following capabilities:

Connects devices through a TCP data channel or through a Telnet connection to computers or to another device server. The xPico 110 wired device server module also supports UDP datagrams.

Contains a web HTTP server allowing presentation of custom content and easy configuration through a browser.

Has eight programmable I/O pins used to monitor or control attached devices.

Applications

The xPico 110 wired device server module connects serial devices such as those listed below to Ethernet networks using the IP protocol family.

Access Control and Physical Security

Door Access Controllers

Biometric Readers

Hand Readers

Electronic Locks and Vaults

Industrial Machines

Label Printers

Print and Apply Solutions

Barcode Printers

Beverage Dispensers

Building Automation

HVAC Systems

Environmental Monitoring

Infrastructure Monitoring

Renewable Energy

EV Charging Piles

EV Charging Stations

Power Inverters

Page 13: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

2: Introduction

xPico® 110 Wired Device Server Module User Guide 13

Protocol Support

The xPico 110 wired device server module uses the Internet Protocol (IP) for network communications. It uses the Transmission Control Protocol (TCP) to assure that no data is lost or duplicated, and that everything sent to the connection arrives correctly at the target.

Supported protocols include:

ARP, TCP/IP, UDP/IP, BOOTP, ICMP, Telnet, TFTP, AutoIP, DHCP, HTTP, and SNMP for network communications and management.

TCP/IP, UDP/IP, and Telnet for connections to the serial port.

TFTP for firmware and web page updates.

IP for addressing, routing, and data block handling over the network.

User Datagram Protocol (UDP) for typical datagram applications in which devices interact with other devices without maintaining a point-to-point connection.

Configuration Methods

For the unit to operate correctly on a network, it must have a unique IP address on the network. There are three basic methods for logging into the device server to assign an IP address and configure the unit:

DeviceInstaller: Assign an IP address and view the current xPico 110 configuration using a Graphical User Interface (GUI) on a PC attached to a network. See 3 Using DeviceInstaller.

Web Manager: Through a web interface, configure the xPico 110 wired device server module and its settings using the xPico 110 unit’s Web Manager. See 4 Configuration Using Web Manager.

Serial & Telnet Ports: There are two approaches to accessing Serial Mode. Make a Telnet connection to the network port (9999) or connect a terminal (or a PC running a terminal emulation program) to the unit’s serial port. See 5 Configuration via Telnet or Serial Port (Setup Mode).

Addresses and Port Numbers

Hardware Address The hardware address is also referred to as the Ethernet address or the MAC address. The first three bytes of the Ethernet address identify the unit as a Lantronix product. The fourth, fifth, and sixth bytes are unique numbers assigned to each unit.

Example: 00-80-A3-14-01-18

Note: Make note of the MAC address. It is needed to locate the xPico 110 wired device server module using the DeviceInstaller utility.

Page 14: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

2: Introduction

xPico® 110 Wired Device Server Module User Guide 14

IP Address Every device connected to an IP network must have a unique IP address. This address is used to reference the specific unit. The xPico 110 wired device server module is automatically assigned an IP address on DHCP-enabled networks, as it is DHCP-enabled by default.

Port Numbers Every TCP connection and every UDP datagram is defined by a destination IP address and a port number. For example, a Telnet application commonly uses port number 23. A port number is similar to an extension on a phone system.

The unit's serial channel (port) can be associated with a specific TCP/UDP port number. Port number 9999 is reserved for access to the unit's Setup (configuration) Mode window. Ports 0-1024 are reserved as well. For more information on reserved port numbers, see to Table 7-4. Reserved Port Numbers on page 45.

Product Information Label

The product information label on the unit contains the following information about the specific unit:

Part Number

Revision

Manufacturing Date Code

Product Model

Country of Origin

Lantronix Datamatrix Barcode

MAC Address

Figure 2-1. Product Label

Part Number Manufacturing Date Code

Lantronix Datamatrix Barcode

Model Name

Country of Manufacturing Origin

Product Revision

Serial Number

Page 15: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

xPico® 110 Wired Device Server Module User Guide 15

3. Using DeviceInstaller This chapter covers the steps for getting the xPico 110 wired device server module online and viewing its current configuration.

Note: DeviceInstaller is a free utility program provided by Lantronix that discovers, configures, upgrades, and manages Lantronix Device Servers. It can be downloaded from the Lantronix website at www.lantronix.com/support/downloads. For instructions on using DeviceInstaller to configure the IP address and related settings or for more advanced features, see the DeviceInstaller Online Help.

Installing DeviceInstaller

To install DeviceInstaller:

1. Download the latest version of DeviceInstaller from http://www.lantronix.com/downloads. The minimum required version that supports supporting xPico 110 is version 4.4.0.4.

2. Run the executable to start the installation process.

3. Respond to the installation wizard prompts. (If prompted to select an installation type, select Typical).

Assigning an IP Address

The unit’s IP address must be configured before it can work correctly on a network. You have several options for assigning an IP to your unit. We recommend that you manually assign the IP address over the network using DeviceInstaller.

Note: To use a serial connection instead of an Ethernet connection to configure the device, see 5 Configuration via Telnet or Serial Port (Setup Mode) on page 39.

The unit’s IP address is normally set to 0.0.0.0 at the factory. The hardware address is on the product label. The unit is DHCP enabled as the default.

To assign an IP address manually:

1. Click StartAll Programs LantronixDeviceInstaller 4.4DeviceInstaller. If your PC has more than one network adapter, a message displays. Select an adapter and click OK.

Note: If the unit already has an IP address (e.g., DHCP has assigned an IP address), click the Search icon and select the unit from the list of Lantronix device servers on the local network.

2. Click the Assign IP icon .

3. If prompted, enter the hardware address (on the product label) and click Next.

Page 16: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

3: Using DeviceInstaller

xPico® 110 Wired Device Server Module User Guide 16

4. Select Assign a specific IP address and click Next.

5. Enter the IP address. The Subnet mask displays automatically based on the IP address; if desired, you may change it. On a local network, you can leave the Default gateway blank (all zeros). Click Next.

6. Click the Assign button and wait several seconds until a confirmation message displays. Click Finish.

7. Select the device from the main window list and select Ping from the Tools menu. The Ping Device dialog box shows the IP address of the selected unit.

8. From the Tools menu, click the Ping button. The results display in the Status window. Click the Clear Status button to clear the window so you can ping the device again.

Note: If you do not receive “Reply” messages, make sure the unit is properly attached to the network and that the IP address assigned is valid for the particular network segment you are working with. If you are not sure, check with your systems administrator.

9. Click the Close button to close the dialog box and return to the main window.

Accessing the xPico 110 Wired Device Server Module Using DeviceInstaller

1. Click StartAll Programs LantronixDeviceInstaller 4.4.

2. Click the xPico folder. The list of available Lantronix xPico modules display.

3. Expand the list of xPico 110 wired device server modules by clicking the + symbol next to the xPico icon. Select the xPico 110 unit by clicking on its IP address to view its configuration.

Viewing the Current Configuration

DeviceInstaller provides a view of the unit's configuration.

To view the unit's current settings:

1. Follow the instructions above to locate the xPico 110 wired device server module.

2. In the right pane, click the Device Details tab. The current xPico 110 configuration displays:

Name Configurable field. A name that identifies the xPico 110 wired device server module. Double-click the field, type in the value, and press Enter to complete. This name is not visible on other PCs or laptops using the DeviceInstaller utility.

Page 17: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

3: Using DeviceInstaller

xPico® 110 Wired Device Server Module User Guide 17

DHCP Device Name Non-configurable field. Displays the name associated with xPico 110 wired device server module’s current IP address, if the IP address was obtained dynamically. To change the DHCP device name, see Configuration Using Web Manager or Configuration via Telnet or Serial Port (Setup Mode).

Group Configurable field. A group name to categorize the xPico 110 wired device server module. Double-click the field, type in the value, and press Enter to complete. This group name is not visible on other PCs or laptops using DeviceInstaller.

Comments Configurable field. Information about the xPico 110 wired device server module. Double-click the field, type in the value, and press Enter to complete. This description or comment is not visible on other PCs or laptops using DeviceInstaller.

Device Family Non-configurable field. Displays the xPico 110 wired device server module’s device family as “xPico.”

Type Non-configurable field. Displays the device type as “xPico 110.”

ID Non-configurable field. Displays the xPico 110 wired device server module’s ID embedded within the unit.

Hardware Address Non-configurable field. Displays the xPico 110 wired device server module’s hardware (or MAC) address.

Firmware Version Non-configurable field. Displays the firmware currently installed on the xPico 110 wired device server module.

Extended Firmware Version Non-configurable field. Displays the full version nomenclature of the firmware.

Online Status Non-configurable field. Displays the xPico 110 wired device server module’s status as online, offline, unreachable (the xPico 110 unit is on a different subnet), or busy (the xPico 110 wired device server module is currently performing a task).

IP Address Non-configurable field. Displays the xPico 110 wired device server module’s current IP address. To change the IP address, see Assigning an IP Address on page 15.

IP Address was Obtained Displays “Dynamically” if the xPico 110 wired device server module automatically received an IP address (e.g., from DHCP). Displays “Statically” if the IP address was configured manually. If the IP address was assigned dynamically, the following fields appear: Obtain via DHCP with value of True or False. Obtain via BOOTP with value of True or False. Obtain via RARP with value of True or False Obtain via Auto IP with value of True or False

Subnet Mask Non-configurable field. Displays the xPico 110 wired device server module’s current subnet mask. To change the subnet mask, see Assigning an IP Address on page 15.

Page 18: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

3: Using DeviceInstaller

xPico® 110 Wired Device Server Module User Guide 18

Gateway Non-configurable field. Displays the xPico 110 wired device server module’s current gateway. To change the gateway, see Assigning an IP Address on page 15.

Number of COB partitions supported

Non-configurable field. Displays the number of COB partitions supported.

Number of Ports Non-configurable field. Displays the number of ports on the xPico 110 wired device server module.

TCP Keepalive Non-configurable field. Displays 1-65s, the xPico 110 wired device server module’s TCP keepalive value. The default setting is 45.

Telnet Supported Non-configurable field. Indicates if Telnet sessions are permitted.

Telnet Port Non-configurable field. Displays the xPico 110 wired device server module’s port for Telnet sessions.

Web Port Non-configurable field. Displays the xPico 110 wired device server module’s port for Web Manager configuration.

Maximum Baud Rate Supported Non-configurable field. Displays the xPico 110 wired device server module’s maximum baud rate. Note: the xPico 110 wired device server module may not currently be running at this rate.

Firmware Upgradeable Non-configurable field. Displays True, indicating the xPico 110 firmware is upgradeable as newer version become available.

Supports Configurable Pins Non-configurable field. Displays True, indicating configurable pins are available on the xPico 110 wired device server module.

Supports Email Triggers Non-configurable field. Displays False, indicating email triggers are not supported on xPico 110 wired device server module.

Supports AES Data Stream Non-configurable field. Displays True. xPico 110 wired device server module supports AES encryption.

Supports 485 Non-configurable field. Displays True. xPico 110 wired device server module supports the RS-485 protocol.

Supports 921K Baud Rate Non-configurable field. Displays True. xPico 110 wired device server module supports baud rates up to 921600 bits per second (bps).

Supports HTTP Server Non-configurable field. Displays True.

Supports HTTP Setup Non-configurable field. Displays True.

Supports 230K Baud Rate Non-configurable field. Displays True.

Supports GPIO Non-configurable field. Displays True, indicating the xPico 110 wired device server module supports General Purpose Input Output (GPIO).

Page 19: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

xPico® 110 Wired Device Server Module User Guide 19

4. Configuration Using Web Manager You must configure the unit so that it can communicate on a network with your serial device. For example, you must set the way the unit will respond to serial and network traffic, how it will handle serial packets, and when to start or close a connection.

The unit’s configuration is stored in nonvolatile memory and is retained without power. You can change the configuration at any time. The unit performs a reset after you change and store the configuration.

In this chapter, we describe how to configure the xPico 110 wired device server module using Web Manager, Lantronix’s browser-based configuration tool. (For information on using Setup Mode, our command line configuration interface, see 5 Configuration via Telnet or Serial Port (Setup Mode).

Note: The examples in this section show a typical device. Your device may have different configuration options.

Accessing Web Manager Using DeviceInstaller

Note: For more information on DeviceInstaller, see 3 Using DeviceInstaller.

1. Run DeviceInstaller and search for the list of available Lantronix device servers.

2. Click on the xPico folder. The list of available xPico 110 wired device server modules display.

3. Expand the list of xPico 110 wired device server modules by clicking the + symbol next to the xPico icon.

4. Select the xPico 110 unit by clicking its hardware address.

5. In the right pane, click the Web Configuration tab.

6. To view the xPico 110 Web Manager in the current DeviceInstaller window, click the Go button. To open the Web Manager in a web browser, click the External Browser button.

Note: Alternatively, to open Web Manager, open your web browser and enter the IP address of the xPico 110 wired device server module.

A dialog box appears to prompt for a User Name and Password.

Page 20: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

4: Configuration Using Web Manager

xPico® 110 Wired Device Server Module User Guide 20

Figure 4-1. Web Manager Login Window

7. Perform one of the following: If no Telnet password has been defined, leave both fields blank and click OK. If a Telnet password has been defined, leave the username blank, type in the password,

and then click OK. The Web Manager displays.

Note: We recommend that you always use the enhanced password setting and create a strong 16 character password. See Security Settings (Option 6) on page 60.

Figure 4-2. Lantronix Web Manager

The main menu is in the left pane of the Web Manager window.

Page 21: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

4: Configuration Using Web Manager

xPico® 110 Wired Device Server Module User Guide 21

Network Configuration

The unit’s network values display when you select Network from the main menu. The following sections describe the configurable parameters on the Network Settings page.

Figure 4-3. Network Settings

Network Mode

1. Click Network from the main menu.

2. Note the following:

Network Mode Wired Only is the only choice. It enables the Ethernet network connectivity.

Automatic IP Address Configuration An IP address can be assigned automatically. You then enter related network settings.

To assign an IP address automatically:

1. On the main menu, click Network.

Page 22: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

4: Configuration Using Web Manager

xPico® 110 Wired Device Server Module User Guide 22

2. Select Obtain IP address automatically.

3. Enter the following (as necessary):

BOOTP Select Enable to permit the Bootstrap Protocol (BOOTP). server to assign the IP address from a pool of addresses automatically. Enable is the default.

DHCP Select Enable to permit the Dynamic Host Configuration Protocol (DHCP) to assign a leased IP address to the xPico 110 unit automatically. Enable is the default.

AutoIP Select Enable to permit the xPico 110 wired device server module to generate an IP in the 169.254.x.x address range with a Class B subnet. Enable is the default.

DHCP Host Name Enter the desired host name for the xPico 110 wired device server module.

Note: Disabling BOOTP, DHCP, and AutoIP (all three checkboxes) is not advised as the only available IP assignment method will then be ARP or serial port.

4. When you are finished, click the OK button.

5. On the main menu, click Apply Settings.

Static IP Address Configuration You manually assign an IP address to the unit and enter related network settings.

To assign an IP address manually:

1. On the main menu, click Network.

2. Select Use the following IP configuration.

3. Enter the following (as necessary):

IP Address If DHCP is not used to assign IP addresses, enter it manually in decimal-dot notation. The IP address must be set to a unique value in the network.

Subnet Mask A subnet mask defines the number of bits taken from the IP address that are assigned for the host part.

Default Gateway The gateway address, or router, allows communication to other LAN segments. The gateway address should be the IP address of the router connected to the same LAN segment as the unit. The gateway address must be within the local network.

DNS Server The DNS server allows the name of a remote machine to be resolved automatically. Enter the IP address of the DNS server. If the device is DHCP enabled, the DHCP server provides the DNS server IP address, which will override this configured value. Note: This setting is applicable only in Manual Connection mode.

Page 23: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

4: Configuration Using Web Manager

xPico® 110 Wired Device Server Module User Guide 23

4. When you are finished, click the OK button.

5. On the main menu, click Apply Settings.

Ethernet Configuration You must specify the speed and direction of data transmission.

To specify how data will be transmitted:

1. On the main menu, click Network.

2. Enter the following (as necessary):

Auto Negotiate With this option, the Ethernet port auto-negotiates the speed and duplex with the hardware endpoint to which it is connected. This is the default. If this option is not selected, the complete the fields that become available: Speed: The speed of data transmission. The default is 100

Mbps. Duplex: The direction of data transmission. The default is

Full.

3. When you are finished, click the OK button.

4. On the main menu, click Apply Settings.

Page 24: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

4: Configuration Using Web Manager

xPico® 110 Wired Device Server Module User Guide 24

Server Configuration

The unit’s server values display when you select Server from the main menu. The following sections describe the configurable parameters on the Server Settings page.

Figure 4-4. Server Settings

To configure the xPico 110 device server settings:

1. On the main menu, click Server.

2. Configure or modify the following fields:

Server Configuration

Enhanced Password Note: We recommend that you always enable the enhanced password setting, and create a strong 16 character password.

Select whether to enable enhanced password: Enable: selecting this option enables enhanced password

creation, allowing you to create passwords up to 16 bytes in length.

Disable: selecting this option disables enhanced password creation, allowing you to create basic passwords up to 4 bytes in length.

Telnet/Web Manager Password

Enter the password required for Telnet configuration and Web Manager access.

Page 25: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

4: Configuration Using Web Manager

xPico® 110 Wired Device Server Module User Guide 25

Retype Password Re-enter the password required for Telnet configuration and Web Manager access.

Advanced

ARP Cache Timeout (secs) When the unit communicates with another device on the network, it adds an entry into its ARP table. ARP Cache timeout defines the number of seconds (1-600) before it refreshes this table. Entering 0 disables the ARP cache timeout.

TCP Keepalive (secs) TCP Keepalive time defines how many seconds the unit waits during an inactive connection before checking its status. If the unit does not receive a response, it drops that connection. Enter a value between 0 and 60 seconds. 0 disables keepalive. The default setting is 45.

Monitor Mode @ Bootup Select Disable to disable entry into the monitor mode using the 'yyy' or 'xx1' key sequence at startup. This field prevents the unit from entering monitor mode by interpreting the stream of characters that are received during the device server's initialization at startup.

CPU Performance Mode Select the xPico 110 wired device server module’s performance mode. Higher performance settings require more energy. Regular is 48 Mhz; High is 88 Mhz. The default is Regular.

HTTP Server Port This option allows the configuration of the web server port number. The valid range is 1-65535. The default port is 80.

Config Server Port Not applicable for this product.

MTU Size The Maximum Transmission Unit (MTU) is the largest physical packet size a network can transmit for TCP and UDP. Enter between 512 and 1400 bytes. The default is 1400 bytes.

TCP Re-transmission timeout (ms)

The desired TCP re-transmission timeout value. If the ACK is not received for a packet sent from the xPico 110 device, then the unit will retransmit the data. The valid range is 500-4000 msec.

3. When you are finished, click the OK button.

4. On the main menu, click Apply Settings.

Host List Configuration

The xPico 110 wired device server module scrolls through the host list until it connects to a device listed in the host list table. After a successful connection, the unit stops trying to connect to any others. If this connection fails, the unit continues to scroll through the table until the next successful connection.

The host list supports a minimum of 1 and a maximum of 12 entries. Each entry contains an IP address and a port number.

Note: The host list is disabled for Manual and Modem Mode. The unit does not accept a data connection from a remote device when the hostlist option is enabled.

Page 26: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

4: Configuration Using Web Manager

xPico® 110 Wired Device Server Module User Guide 26

To configure the xPico 110 host list:

1. On the main menu, click Hostlist.

Figure 4-5. Hostlist Settings

2. Enter or modify the following fields:

Retry Settings Retry Counter Enter the value for the number of times the xPico 110 wired

device server module should attempt to retry connecting to the host list.

Retry Timeout Enter the duration (in milliseconds) the xPico 110 wired device server module should abandon attempting a connection to the host list.

Host Information

Host Address Enter or modify the host’s IP address.

Port Enter the target port number.

3. When you are finished, click the OK button.

4. On the main menu, click Apply Settings.

Page 27: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

4: Configuration Using Web Manager

xPico® 110 Wired Device Server Module User Guide 27

Channel 1 and 2 Configuration

The Channel 1 and Channel 2 configuration define how the serial ports respond to network and serial communication.

Note: Directions for configuring Channel 1 serial settings and connection apply for Channel 2 configuration, except where indicated.

Serial Settings To configure the channel’s serial settings:

1. On the main menu, click Serial Settings (under Channel 1) to display the Serial Settings window.

Figure 4-6. Channel Serial Settings

2. In the available fields, enter the following information:

Channel 1

Disable Serial Port When selected, disables communication through the serial port. The serial port is enabled by default. Note: This checkbox only applies to Channel 2.

Page 28: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

4: Configuration Using Web Manager

xPico® 110 Wired Device Server Module User Guide 28

Port Settings

Protocol From the drop-down menu, select the protocol type for the selected channel. Channel 1: RS232, RS422/RS485 – 4 wire or RS485 – 2 wire

protocols. Channel 2: RS232 only

Flow Control Flow control manages data flow between devices in a network to ensure it is processed efficiently. Too much data arriving before a device is prepared to manage it causes lost or retransmitted data. None is the default. Channel 1: None, Xon/Xoff, Xon/Xoff Pass Chars to Host or

CTS/RTS (hardware). Channel 2: None, Xon/Xoff or Xon/Xoff Pass Chars to Host

Baud Rate The unit and attached serial device, such as a modem, must agree on a speed or baud rate to use for the serial connection. Valid baud rates are 300, 600, 1200, 2400, 4800, 9600 (default), 19200, 38400, 57600, 115200, or 230400, 460800, or 921600 Note: It is recommended to use hardware flow control for baud rates of 38400 and higher or it could result in data loss. Baud rates 460800 and 921600 are available for selection only when CPU performance mode is set to High.

Data Bits Indicates the number of bits in a transmitted data package. The default is 8.

Parity Checks for the parity bit. The default is None.

Stop Bits The stop bit follows the data and parity bits in serial communication. It indicates the end of transmission. The default is 1.

Pack Control

Enable Packing Select to enable packing on the xPico 110 wired device server module. Two firmware-selectable packing algorithms define how and when packets are sent to the network. The standard algorithm is optimized for applications in which the unit is used in a local environment, allowing for very small delays for single characters, while keeping the packet count low. The alternate packing algorithm minimizes the packet count on the network and is especially useful in applications in a routed Wide Area Network (WAN). Adjusting parameters in this mode can economize the network data stream. Disabled by default.

Idle Gap Time Select the maximum time for inactivity. The default time is 12 milliseconds.

Match 2 Byte Sequence Use to indicate the end of a series of data to be sent as one group. The sequence must occur sequentially to indicate end of the data collection to the xPico 110 wired device server module. The default is No.

Match Bytes Use to indicate the end of a series of data to be sent as one group. Set this value to 00 if specific functions are not needed.

Page 29: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

4: Configuration Using Web Manager

xPico® 110 Wired Device Server Module User Guide 29

Send Frame Immediate After the detection of the byte sequence, indicates whether to send the data frame or the entire buffer. Select Yes to send only the data frame. The default setting is No.

Send Trailing Bytes Select the number of bytes to send after the end-of-sequence characters. The default is None.

Flush Input Buffer (Serial to Network)

With Active Connect Select Yes to clear the input buffer with a connection that is initiated from the device to the network. The default is No.

With Passive Connect Select Yes to clear the input buffer with a connection initiated from the network to the device. The default is No.

At Time of Disconnect Select Yes to clear the input buffer when the network connection to or from the device is disconnected. The default is No.

Flush Output Buffer (Network to Serial)

With Active Connect Select Yes to clear the output buffer with a connection that is initiated from the device to the network. The default is No.

With Passive Connect Select Yes to clear the output buffer with a connection initiated from the network to the device. The default is No.

At Time of Disconnect Select Yes to clear the output buffer when the network connection to or from the device is disconnected. The default is No.

3. When you are finished, click the OK button.

4. On the main menu, click Apply Settings.

Page 30: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

4: Configuration Using Web Manager

xPico® 110 Wired Device Server Module User Guide 30

Connection Settings - TCP To configure a channel’s TCP settings:

1. On the main menu, click Connection. The Connection Settings window for the channel displays.

Figure 4-7. TCP Connection Settings

Page 31: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

4: Configuration Using Web Manager

xPico® 110 Wired Device Server Module User Guide 31

2. In the available fields, enter or modify the following information:

Connect Protocol

Protocol From the drop-down menu, select TCP.

Connect Mode: Passive Connection

Accept Incoming Select Yes to accept incoming connections. The default is Yes.

Password Required Determines whether a password is required for an incoming passive connection. This field is not available when a password is set for Telnet mode.

Password If Password Required was set to Yes, enter the password for passive connections.

Modem Escape Sequence Pass Through

Select Yes or No to indicate whether you wish to enable modem escape sequence pass through. Yes is selected by default.

Connect Mode: Active Connection

Active Connect Select None to disable Active Connect. Otherwise, indicate the connection type from the drop-down list: With Any Character: Attempts to connect when any

character is received from the serial port. With Active Mdm Ctrl In: Accepts external connection

requests only when the Modem Control In input is asserted.

With Start Character: Attempts to connect when it receives a specific start character from the serial port. The default start character is carriage return.

Manual Connection: Attempts to connect when directed by a command string received from the serial port.

Auto Start: Automatically connects to the remote IP address and port after booting up.

Start Character If Active Connect is set to With Start Character, enter the start character in this field.

Modem Mode Indicates the on-screen response type when in Modem Mode (if Modem Mode is enabled).

Show IP Address After Ring

Indicates whether to display the remote IP address upon connection. The default setting is Yes.

Endpoint Configuration

Local Port Enter the local port number.

Auto increment Local Port for active connect

Select to auto-increment the local port number for new outgoing connections. The range of auto-incremented port numbers is 50,000 to 59,999 and loops back to the beginning when the maximum range is reached.

Remote Port Enter the remote port number.

Remote Host Enter the IP address of the remote device.

Page 32: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

4: Configuration Using Web Manager

xPico® 110 Wired Device Server Module User Guide 32

Common Options

Telnet Com Port Cntrl This field is available for configuration only when Active Connect is set to None. Select Enable to permit Telnet communication to the unit. The Telnet Com Port Cntrl feature is used in conjunction with the Com Port Redirector (CPR) utility. (See the CPR online Help for details.)

Terminal Name This field is available for configuration only when Telnet Mode is set to Enable. Use the terminal name for the Telnet terminal type. Enter only one name. When this option is enabled, the unit also reacts to the end of record (EOR) and binary options, which can be used for applications such as terminal emulation to IBM hosts.

Connect Response A single character is transmitted to the serial port when there is a change in connection state. Default setting is None.

Use Hostlist If this option is set to True, the device server scrolls through the host list until it connects to a device listed in the host list table. Once it connects, the unit stops trying to connect to any others. If this connection fails, the unit continues to scroll through the table until it connects to another IP in the host list. The host list is disabled for Manual Mode and for Modem Mode. The unit will not accept a data connection from a remote device when the host list option is enabled.

LED Select Blink for the status LEDs to blink upon connection or None for no LED output.

Disconnect Mode

On Mdm_Ctrl_In Drop Set to Yes for the network connection to or from the serial port to disconnect (drop) when Modem Control In transitions from an asserted state to not asserted state. The default setting is No.

Hard Disconnect When set to Yes, the TCP connection closes even if the remote site does not acknowledge the disconnect request.

Check EOT (Ctrl-D) Select Yes to drop the connection when Ctrl-D or Hex 04 is detected. Both Telnet Com Port Cntrl and Check EOT (Ctrl+ D) must be enabled for Disconnect with EOT to function properly. Ctrl+D is only detected going from the serial port to the network. The default setting is No.

Inactivity Timeout Use this parameter to set an inactivity timeout. The unit drops the connection if there is no activity on the serial line before the set time expires. Enter time in the format mm:ss, where m is the number of minutes and s is the number of seconds. To disable the inactivity timeout, enter 00:00.

3. When you are finished, click the OK button.

4. On the main menu, click Apply Settings.

Page 33: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

4: Configuration Using Web Manager

xPico® 110 Wired Device Server Module User Guide 33

Connection Settings - UDP To configure a channel’s UDP settings:

1. On the main menu, click Connection. The Connection Settings window for the selected channel displays.

2. In the available fields, enter or modify the following information:

Figure 4-8. UDP Connection Settings

Connect Protocol

Protocol Select UDP from the drop-down menu.

Datagram Mode

Datagram Type Configures the remote IP or network broadcast address and the remote port. Enter 01 for directed or broadcast UDP. The default setting is 00.

Accept Incoming Select Yes to accept incoming UDP datagrams.

Endpoint Configuration

Local Port Enter the local port number.

Remote Port Enter the port number of the remote device.

Page 34: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

4: Configuration Using Web Manager

xPico® 110 Wired Device Server Module User Guide 34

Remote Host Enter the IP address of the remote device.

Use Broadcast Select to broadcast the UDP datagram. The default is not to broadcast. Note: Datagrams are sent as subnet-directed broadcasts.

Device Address Table The table is enabled when Datagram Type is set to FD. Enter values between 1 and 255 to identify units on the local network of device servers. Note: Lantronix Tech Support supports Datagram type 01. Datagram Type FD is for OEM use.

3. When you are finished, click the OK button.

4. On the main menu, click Apply Settings.

Configurable Pin Settings

There are eight configurable hardware pins on the xPico 110 unit. For each pin, configure the pin function, communication direction, and activity level. For more information, see 9 GPIO Interface.

To configure the xPico 110 wired device server module’s Configurable Pins:

1. On the main menu, click Configurable Pins. The Configurable Pins page opens.

Figure 4-9. Configurable Pins Settings

2. Configure or modify the following fields for each pin:

Function From the drop-down menu, select the purpose of the specified pin. See Configurable Pin Functions (below) for a description of each available function.

Direction Select whether the pin inputs or outputs.

Active Level Select the signal active level (Low or High).

Page 35: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

4: Configuration Using Web Manager

xPico® 110 Wired Device Server Module User Guide 35

Configurable Pin Functions General Purpose I/O Monitors input using the 77F0 port or controls output by the

77F0 port.

Modem Ctrl Channel 1 In For DTE device configuration this would be the DCD control line.

Modem Ctrl Channel 1 Out For DTE device configuration this would be the DTR control line.

RS485 Select Channel 1 Optional control signal that enables toggling between RS232 and RS485 on OEM hardware design.

RS485 2-Wire Channel 1 Optional control signal that enables toggling between RS485 2-wire and 4-wire mode on OEM hardware design.

Serial Channel 1 Status LED Indicates channel 1 status and extended diagnostics.

Serial Channel 2 Status LED Indicates channel 2 status and extended diagnostics.

3. When you are finished, click the OK button.

4. On the main menu, click Apply Settings.

Apply Settings

1. To save and apply the configuration changes to the device server, click the Apply Settings button.

Note: Clicking OK on each page does not change the configuration on the device. Clicking the OK button tells the xPico 110 wired device server module what changes to use; the Apply Settings button makes the changes permanent and reboots the xPico 110 wired device server module.

Apply Defaults

1. Click the Apply Defaults button to set the device server back to the default settings. For details see Default Settings on page 64.

2. Click Yes to set factory settings or click No to cancel.

Page 36: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

4: Configuration Using Web Manager

xPico® 110 Wired Device Server Module User Guide 36

Figure 4-10. Apply Settings and Apply Defaults

Page 37: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

xPico® 110 Wired Device Server Module User Guide 37

5. Configuration via Telnet or Serial Port (Setup Mode)

You must configure the unit so that it can communicate on a network with your serial device. As an alternative to using a web browser, as described in the previous chapter, you can use the following procedures remotely or locally:

Use a Telnet connection to configure the unit over the network.

Use a terminal or terminal emulation program to access the serial port locally.

The series of prompts at which you enter configuration settings is called Setup Mode.

Note: Detailed information about other setup methods is available from your Lantronix Sales Associate.

The unit’s configuration is stored in nonvolatile memory and is retained without power. You can change the configuration at any time. The unit performs a reset after the configuration has been changed and stored.

This chapter tells you how to access Setup Mode and the general procedure for using it. To complete the configuration, continue with 6 Setup Mode: Server Configuration, 7 Setup Mode: Channel Configuration, and 8 Setup Mode: Advanced Settings.

Note: The menus in the configuration chapters show a typical device. Your device may have different configuration options.

Accessing Setup Mode

Telnet Connection To configure the unit over the network, establish a Telnet connection to port 9999.

Note: You can also use DeviceInstaller to access Telnet. Select the device from the main window list, and click the Telnet Configuration tab. Skip steps 1 and 2.

Page 38: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

5: Configuration via Telnet or Serial Port (Setup Mode)

xPico® 110 Wired Device Server Module User Guide 38

To establish a Telnet connection:

1. From the Windows Start menu, click Run and type the following command, where x.x.x.x is the IP address, and 9999 is the unit’s fixed network configuration port number:

Windows: telnet x.x.x.x 9999

UNIX: telnet x.x.x.x:9999

2. Click OK. The following information displays.

Figure 5-1. xPico 110 Address

MAC address DC82F6000119 Software version V6.11.0.5RC1 (161006) XPICO-SMT AES library version 1.8.2.1 Press Enter for Setup Mode

3. To enter Setup Mode, press Enter within 5 seconds. The configuration settings display, followed by the Change Setup menu.

Figure 5-2. Setup Menu Options

Change Setup:

0 Server

1 Channel 1

2 Channel 2

5 Expert

6 Security

7 Defaults

8 Exit without save

9 Save and exit Your choice ?

4. Select an option on the menu by entering the number of the option in the Your choice ? field and pressing Enter.

5. To enter a value for a parameter, type the value and press Enter, or to confirm a current value, just press Enter.

6. When you are finished, save the new configuration (option 9). The unit reboots.

Page 39: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

5: Configuration via Telnet or Serial Port (Setup Mode)

xPico® 110 Wired Device Server Module User Guide 39

Serial Port Connection To configure the unit through a serial connection:

1. Connect a console terminal or PC running a terminal emulation program to your unit's serial port.

2. Set the terminal emulator serial port settings to 9600 baud, 8 bits, no parity, 1 stop bit, no flow control.

Note: The xPico 110 wired device server module always uses these serial port settings on boot-up.

3. Reset the xPico 110 unit by cycling the unit's power (turning the power off and back on). Immediately upon resetting the device, enter three lowercase x characters (xxx).

Note: The easiest way to enter Setup Mode is to hold down the x key at the terminal (or emulation) while resetting the unit. You must do this within three seconds of resetting the xPico 110 wired device server module.

At this point, the screen display is the same as when you use a Telnet connection. To continue, go to step 4, above, in the section, Telnet Connection.

Exiting Setup Mode

To exit setup mode:

You have two options:

To save all changes and reboot the device, select option 9 Save and exit from the Change Setup menu. All values are stored in nonvolatile memory.

To exit the configuration mode without saving any changes or rebooting, select option 8 Exit without save from the Change Setup menu.

Page 40: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

xPico® 110 Wired Device Server Module User Guide 40

6. Setup Mode: Server Configuration This chapter explains how to configure the network settings.

Note: Current values appear in parentheses.

Server Configuration (Option 0)

The unit’s basic network parameters display when you select Server configuration (option 0). The IP Address, Set Gateway IP Address, and Netmask fields display the current values.

IP Address : (000) .(000) .(000) .(000)

Set Gateway IP Address (N) ?

Netmask: Number of Bits for Host Part (0=default) (0)

Set DNS Server IP addr (N) ?

Change Telnet/Web Manager password (N) ?

IP Address

If DHCP is not used to assign IP addresses, enter the IP address manually. The IP address must be set to a unique value in the network. Enter each octet and press Enter between each section. The current value displays in parentheses.

IP Address : ( 0) ( 0) ( 0) ( 0) _

If DHCP is used, the third octet of the IP address sets the BootP/DHCP/AutoIP options. The following table shows the bits you can manually configure to force the xPico 110 wired device server module to disable AutoIP, DHCP, or BootP. To disable an option, set the appropriate bit.

Table 6-1. BootP/DHCP/AutoIP Options

Options Bit AutoIP 0

DHCP 1

BootP 2

For example, if the third octet is 0.0.5.0, the AutoIP and BootP options are disabled; only DHCP is enabled. (The value 5 results from adding the binary equivalents of 0 and 2.) This is the most common setting when using DHCP.

Page 41: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

6: Setup Mode: Server Configuration

xPico® 110 Wired Device Server Module User Guide 41

Set Gateway IP Address

The gateway address, or router, allows communication to other LAN segments. The gateway address should be the IP address of the router connected to the same LAN segment as the unit. The gateway address must be within the local network. The default is N (No), meaning the gateway address has not been set. To set the gateway address, type Y and enter the address.

Set Gateway IP Address (N) ? Y

Gateway IP addr (000) (000) (000) (000)_

Netmask: Number of Bits for Host Part

A netmask defines the number of bits taken from the IP address that are assigned for the host part.

Netmask: Number of Bits for Host Part (0=default) (0) _

Note: Class A: 24 bits; Class B: 16 bits; Class C: 8 bits

The unit prompts for the number of host bits to be entered, then calculates the netmask, which appears in standard decimal-dot notation (for example, 255.255.255.0) when the saved parameters display.

Table 6-2. Standard IP Network Netmasks

Network Class Host Bits Netmask

A 24 255.0.0.0

B 16 255.255.0.0

C 8 255.255.255.0

Set DNS Server IP Address

The DNS server allows the name of a remote machine to be resolved automatically. The default is N (No), indicating the DNS server address has not been set. To set the DNS server address, type Y. At the prompt, enter the DNS server address. If the device is DHCP enabled, the DHCP server provides the DNS server IP address, which will override this configured value.

Note: This setting is applicable only in Manual Connection mode.

Set DNS Server IP addr <N> ?

Page 42: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

6: Setup Mode: Server Configuration

xPico® 110 Wired Device Server Module User Guide 42

Change Telnet/Web Manager Password

Setting the Telnet/Web Manager password prevents unauthorized access to the setup menu through a Telnet connection to port 9999 or through web pages.

Please protect your device from unauthorized access and follow the instructions below:

Always select Y to enable Telnet/Web Manager password

Enable the enhanced password setting and create a strong 16-character password. For details, see Security Settings (Option 6) on page 60.

Note: We do not recommend that you only use the 4-character basic password as it does not offer sufficient security. Using no password is very dangerous.

Change Telnet/Web Manager password (N) ? _

DHCP Name

If a DHCP server has automatically assigned the IP address and network settings, you can discover the unit by using the DeviceInstaller network search feature.

There are three methods for assigning DHCP names to the unit.

Default DHCP Name: If you do not change the DHCP name, and you are using an IP of 0.0.0.0, then the DHCP name defaults to CXXXXXX (XXXXXX is the last 6 digits of the MAC address shown on the label on the bottom/side of the unit). For example, if the MAC address is 00-20-4A-12-34-56, then the default DHCP name is C123456.

Custom DHCP Name: You can create your own DHCP name. If you are using an IP address of 0.0.0.0, then the last option in Server configuration is Change DHCP device name. This option allows you to change the DHCP name to an alphanumeric name (LTX in our example).

Change DHCP device name (not set) ? (N) Y

Enter new DHCP device name : LTX

Numeric DHCP Name: You can change the DHCP name by specifying the last octet of the IP address. When you use this method, the DHCP name is LTXYY where YY is what you chose for the last octet of the IP address. If the IP address you specify is 0.0.0.12, then the DHCP name is LTX12. This method only works with 2 digit numbers (01-99).

Page 43: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

xPico® 110 Wired Device Server Module User Guide 43

7. Setup Mode: Channel Configuration This chapter explains how to configure the serial port.

Channel 1 (Option 1) or Channel 2 (Option 2) Select Channel 1 (option 1) or Channel 2 (option 2) from the Change Setup menu to define how the serial port responds to network and serial communications. The following sections describe the configurable parameters within the Channel configuration menu.

Figure 7-1. Serial Port Parameters

Baudrate (9600) ?

I/F Mode (4C) ?

Flow (00) ?

Port No (10001) ?

ConnectMode (C0) ?

Send '+++' in Modem Mode (Y) ?

Show IP addr after 'RING' (Y) ?

Auto increment source port (N) ?

Remote IP Address : (000) .(000) .(000) .(000)

Remote Port (0) ?

DisConnMode (00) ?

FlushMode (00) ?

DisConnTime (00:00) ?:

SendChar 1 (00) ?

SendChar 2 (00) ?

Baudrate The unit and attached serial device, such as a modem, must agree on a speed or baud rate to use for the serial connection. Valid baud rates are 300, 600, 1200, 2400, 4800, 9600 (default), 19200, 38400, 57600, 115200, and 230400 bits per second. xPico 110 wired device server module also supports high-performance baud rates of 460800 and 921600 bits per second. (See CPU Performance on page 59).

Baudrate (9600) ? _

Page 44: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

7: Setup Mode: Channel Configuration

xPico® 110 Wired Device Server Module User Guide 44

I/F (Interface) Mode

The Interface (I/F) Mode is a bit-coded byte entered in hexadecimal notation.

I/F Mode (4C) ? _

The following table displays available I/F Mode options:

Note: All bit positions in the table that are blank represent “don’t care” bits for that particular option, which can be set to either a 0 or 1 value.

Table 7-1. Interface Mode Options

I/F Mode Option 7 6 5 4 3 2 1 0 RS-232C (1) 0 0

RS-422/485 0 1

RS-485 2-wire 1 1

7 Bit 1 0

8 Bit 1 1

No Parity 0 0

Even Parity 1 1

Odd Parity 0 1

1 stop bit 0 1

2 stop bits (1) 1 1

(1) 2 stop bits are implemented by the software. This might influence performance.

The following table demonstrates how to build some common Interface Mode settings:

Table 7-2. RS232 Interface Mode Settings

Common I/F Mode Setting Binary Hex RS-232C, 8-bit, No Parity, 1 stop bit 0100 1100 4C

RS-232C, 7-bit, Even Parity, 1 stop bit 0111 1000 78

Flow

Flow control sets the local handshaking method for stopping serial input/output.

Flow (00) ? _

Page 45: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

7: Setup Mode: Channel Configuration

xPico® 110 Wired Device Server Module User Guide 45

Use the following table to select flow control options:

Table 7-3. Flow Control Options

Flow Control Option Hex

No flow control 00

XON/XOFF flow control 01

Hardware handshake with RTS/CTS lines 02

XON/XOFF pass characters to host 05

Port Number

The setting represents the source port number in TCP connections. It is the number that identifies the channel for remote initiating connections.

Port No (10001) ? _

The default setting for Port 1 is 10001. The default setting for Port 2 is 10002. The range is 1-65535, except for the following reserved port numbers:

Table 7-4. Reserved Port Numbers

Port Numbers Reserved for

1 – 1024 Reserved (well known ports)

9999 Telnet setup

14000-14009 Reserved for Redirector

30704 Reserved (77F0h)

30718 Reserved (77FEh)

WARNING: We recommend that you not use the reserved port numbers for this setting as incorrect operation may result.

Use Port 0 for the outgoing local port to change with each connection. The port range is 50,000 to 59,999. Each subsequent connection increments the number by 1 (it wraps back around to 50,000).

Only use this automatic port increment feature to initiate a connection using TCP. Set the port to a non-zero value when the unit is in a passive mode or when using UDP instead of TCP.

Connect Mode

Connect Mode defines how the unit makes a connection, and how it reacts to incoming connections over the network.

ConnectMode (C0) ? _

Page 46: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

7: Setup Mode: Channel Configuration

xPico® 110 Wired Device Server Module User Guide 46

Enter Connect Mode options in hexadecimal notation.

Note: All bit positions in the table that are blank represent “don’t care” bits, for that particular option, which can be set to either a 0 or 1 value.

Table 7-5. Connect Mode Options

Connect Mode Option 7 6 5 4 3 2 1 0

a) Incoming Connection

Never accept incoming 0 0 0

Accept with active Modem Control In 0 1 0

Always Accept 1 1 0

b) Response

Nothing (quiet) 0

Character response (C=connect, D=disconnect, N=unreachable) 1

c) Active Startup

No active startup 0 0 0 0

With any character 0 0 0 1

With active Modem Control In 0 0 1 0

With a specific start character 0 0 1 1

Manual connection 0 1 0 0

Autostart 0 1 0 1

Hostlist 0 0 1 0

d) Datagram Type

Directed UDP 1 1 0 0

e) Modem Mode

No Echo 0 0 1 1 Data Echo & Modem Response (Numeric) 0 1 1 1 1

Data Echo & Modem Response (Verbose) 0 1 1 1 0

Modem Response Only (Numeric) 0 0 1 1 1 1

Modem Response Only (Verbose) 0 0 1 1 1 0

a) Incoming Connection

Never Accept Incoming Rejects all external connection attempts.

Accept with active Modem Accepts external connection requests only when the Modem

Page 47: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

7: Setup Mode: Channel Configuration

xPico® 110 Wired Device Server Module User Guide 47

Control In Control In input is asserted. Cannot be used with Modem Mode.

Always Accept Accepts any incoming connection when a connection is not already established. Default setting.

b) Response

Character Response A single character is transmitted to the serial port when there is a change in connection state: C = connected, D = disconnected, N = host unreachable. The IP address of the host connecting to the CoBos device will be provided when you use verbose mode. This option is overridden when the Active Start Modem Mode or Active Start Host List is in effect. Default setting is Nothing (quiet).

c) Active Startup

No Active Startup Does not attempt to initiate a connection under any circumstance. Default setting.

With Any Character Attempts to connect when any character is received from the serial port.

With active Modem Control In

Attempts to connect when the Modem Control In input changes from not asserted to asserted.

With a Specific Start Character

Attempts to connect when it receives a specific start character from the serial port. The default start character is carriage return.

Page 48: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

7: Setup Mode: Channel Configuration

xPico® 110 Wired Device Server Module User Guide 48

Manual Connection Attempts to connect when directed by a command string received from the serial port. The first character of the command string must be a C (ASCII 0x43), and the last character must be either a carriage return (ASCII 0x0D) or a line feed (0x0A). No blanks or space characters may be in the command string. Between the first and last command string characters must be a full or partial destination IP address and may be a destination port number. The IP address must be in standard decimal-dot notation and may be a partial address, representing the least significant 1, 2, or 3 bytes of the remote IP address. The period is required between each pair of IP address numbers. If present, the port number must follow the IP address, must be presented as a decimal number in the range 1-65535, and must be preceded by a forward slash (ASCII 0x2F). The slash separates the IP address and the port number. If you omit the port number from a command string, the internally stored remote port number starts a connection. If a partial IP address is presented in a command string, it is interpreted to be the least significant bytes of the IP address and uses the internally stored remote IP address to provide the most significant bytes of the IP address. If the IP address entered is 0.0.0.0/0, the device server enters Monitor Mode. For example, if the remote IP address already configured in the unit is 129.1.2.3, then an example command string would be C3/7. (This would connect to 129.1.2.3 and port 7.) You may also use a different ending for the connection string. For example, C50.1/23 would connect you to 129.1.50.1 and port 23. If an IP address does not follow the first command string character (which is "C"), the subsequent character string is interpreted as the host name and domain to be used in DNS lookup. This character string can include a destination port number as well. The port number can be preceded by either a forward slash (/) or a colon ( : ).

Table 7-6. Manual Connection Address Example

Command String Result if remote IP is 129.1.2.3 and remote port is 1234

C121.2.4.5/1 Complete override; connection is started with host 121.2.4.5, port 1

C5 Connects to 129.1.2.5, port 1234

C28.10/12 Connects to 129.1.28.10, port 12

C0.0.0.0/0 Enters Monitor Mode

Cwww.lantronix.com/80 Tries to connect to the Lantronix web server if the <hostname:domain> (www.lantronix.com) is configured in the DNS server database.

Autostart (Automatic Connection)

If you enable Autostart, the unit automatically connects to the remote IP address and remote port specified when the firmware starts.

Hostlist If you enable this option, the device server scrolls through the hostlist until it connects to a device listed in the hostlist table. Once it connects, the unit stops trying to connect to any others.

Page 49: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

7: Setup Mode: Channel Configuration

xPico® 110 Wired Device Server Module User Guide 49

Command String Result if remote IP is 129.1.2.3 and remote port is 1234

If this connection fails, the unit continues to scroll through the table until it is able to connect to another IP in the hostlist. Hostlist supports a minimum of 1 and a maximum of 12 entries. Each entry contains the IP address and the port number. The hostlist is disabled for Manual and Modem Modes. The unit does not accept a data connection from a remote device when the hostlist option is enabled.

Figure 7-2. Hostlist Option

Baudrate (9600) ?

I/F Mode (4C) ?

Flow (00) ?

Port No (10001) ?

ConnectMode (C0) ? 25

Send '+++' in Modem Mode (Y) ?

Show IP addr after 'RING' (Y) ?

Auto increment source port (N) ?

Hostlist :

01. IP : 172.019.205.011 Port : 00001

02. IP : 172.019.205.012 Port : 00002

03. IP : 172.019.205.013 Port : 00003

Change Hostlist ? (N) ?

Hostlist Retrycounter (3) ?

Hostlist Retrytimeout (250) ?

DisConnMode (00) ?

FlushMode (00) ?

DisConnTime (00:00) ?:

SendChar 1 (00) ?

SendChar 2 (00) ?

Page 50: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

7: Setup Mode: Channel Configuration

xPico® 110 Wired Device Server Module User Guide 50

To enable the hostlist:

1. Enter a Connect Mode of 0x20 (2X), where X is any digit. The menu shows you a list of current entries already defined in the product.

2. To delete, modify, or add an entry, select Yes. If you enter an IP address of 0.0.0.0, that entry and all others after it are deleted.

3. After completing the hostlist, repeat the previous step if necessary to edit the hostlist again.

4. For Retrycounter, enter the number of times the Lantronix unit should try to make a good network connection to a hostlist entry that it has successfully ARPed. The range is 1-15, with the default set to 3.

5. For Retrytimeout, enter the number of seconds the unit should wait before failing an attempted connection. The time is stored as units of milliseconds in the range of 10-65535. The default is 250.

d) Datagram Type

Directed UDP When selecting this option, you are prompted for the Datagram type. Enter 01 for directed or broadcast UDP. Datagrams of type 01 can be sent as a broadcast by enabling the Send as Broadcast option. The default is not to broadcast. When the UDP option is in effect, the unit never attempts to initiate a TCP connection because it uses UDP datagrams to send and receive data.

e) Modem Mode In Modem (Emulation) Mode, the unit presents a modem interface to the attached serial device. It accepts AT-style modem commands and handles the modem signals correctly.

Normally, there is a modem connected to a local PC and a modem connected to a remote machine. A user must dial from the local PC to the remote machine, accumulating phone charges for each connection. Modem Mode allows you to replace modems with xPico 110 wired device server modules, and to use an Ethernet connection instead of a phone call. By not having to change communications applications, you avoid potentially expensive phone calls.

To select Modem Mode, set the Connect Mode to C6 (no echo), D6 (echo with full verbose), D7 (echo with numeric response), CF (modem responses only, numeric response), or CE (modem responses only, full verbose).

Note: If the unit is in Modem Mode, and the serial port is idle, the unit can still accept network TCP connections to the serial port if Connect Mode is set to C6 (no echo), D6 (echo with full verbose), D7 (echo with numeric response, CF (modem responses only, numeric response), or CE (modem responses only, full verbose).

Without Echo In Modem Mode, echo refers to the echo of all of the characters entered in command mode; it does not mean to echo data that is transferred. Quiet Mode (without echo) refers to the modem not sending an answer to the commands received (or displaying what was typed).

Data Echo & Modem Response

Full Verbose: The unit echoes modem commands and responds to a command with a message string shown in the table below.

Page 51: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

7: Setup Mode: Channel Configuration

xPico® 110 Wired Device Server Module User Guide 51

Numeric Response: The unit echoes modem commands and responds to a command with a numeric response.

Modem Responses Only Full Verbose: The unit does not echo modem commands and responds to a command with a message string shown in the table below. Numeric Response: The unit does not echo modem commands and responds to a command with a numeric response.

Table 7-7. Modem Mode Messages

Message Meaning

Full Verbose

OK Command was executed without error.

CONNECT A network connection has been established.

NO CARRIER A network connection has been closed.

RING n.n.n.n. A remote device, having IP address n.n.n.n, is connecting to this device.

Numeric Response

0 OK

1 Connected

2 Ring

3 No Carrier

4 Error

Received commands must begin with the two-character sequence AT and be terminated with a carriage return character.

The unit ignores any character sequence received not starting with AT, and only recognizes and processes single AT-style commands. The unit treats compound AT commands as unrecognized commands.

If the Full Verbose option is in effect, the unit responds to an unrecognized command string that is otherwise formatted correctly (begins with AT and ends with carriage return) with the "OK" message and takes no further action.

If the Numeric Response option is in effect, the unit responds to an unrecognized command string that is otherwise formatted correctly with the "OK" message and takes no further action.

When an active connection is in effect, the unit transfers data and does not process commands received from the serial interface.

When a connection is terminated or lost, the unit reverts to command mode.

When an active connection is in effect, the unit terminates the connection if it receives the following sequence from the attached serial device:

No serial data is received for one second.

Page 52: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

7: Setup Mode: Channel Configuration

xPico® 110 Wired Device Server Module User Guide 52

The character sequence +++ is received, with no more than one second between each two characters.

No serial data is received for one second after the last + character. At this time, the unit responds affirmatively per the selected echo/response mode.

The character string ATH is received, terminated with a carriage return. The unit responds affirmatively according to the selected echo/response mode and drops the network connection. The serial interface reverts to accepting command strings.

If this sequence is not followed, the unit remains in data transfer mode.

Table 7-8. Modem Mode Commands

Modem Mode Command Function

ATDTx.x.x.x,pppp, ATDTx.x.x.x/pppp, or ATDTx.x.x.x:pppp

Makes a connection to an IP address (x.x.x.x) and a remote port number (pppp).

ATDTx.x.x.x Makes a connection to an IP address (x.x.x.x) and the remote port number defined within the unit.

ATD0.0.0.0 Forces the unit into Monitor Mode if a remote IP address and port number are defined within the unit.

ATD or ATDT Forces the unit into Monitor Mode if a remote IP address and port number are not defined within the unit.

ATDx.x.x.x Makes a connection to an IP address (x.x.x.x) and the remote port number defined within the unit.

ATH Hangs up the connection (Entered as +++ATH ).

ATS0=n

Enables or disables connections from the network going to the serial port. n=0 disables the ability to make a connection from the network to the serial port. n=1-9 enables the ability to make a connection from the network to the serial port. n>1-9 is invalid.

ATEn

Enables or disables character echo and responses. n=0 disables character echo and responses. n=1 enables character echo and responses.

ATVn

Enables numeric response or full verbose. n=0 enables numeric response. n=1 enables full verbose.

Note: The unit recognizes these AT commands as single commands such as ATE0 or ATV1; it does not recognize compound commands such as ATE0V.

Page 53: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

7: Setup Mode: Channel Configuration

xPico® 110 Wired Device Server Module User Guide 53

Send the Escape Sequence (+++) in Modem Mode

Send ‘+++’ in Modem Mode (Y) ? _

Disable or enable the xPico 110 wired device server module’s ability to send the escape sequence. The default is Y (Yes) (send the escape sequence).

Show IP addr after 'RING'

Show IP addr after 'RING' (Y)

Disable or enable the xPico 110 wired device server module's ability to show the IP address after RING in Modem Mode. The default is Y (Yes), to show the IP address.

Auto Increment Source Port

Auto increment source port (N) ? _

Y (Yes) auto increment the source port. The xPico 110 wired device server module increments the port number used with each new connection.

Remote IP Address

This is the destination IP address used with an outgoing connection.

Remote IP Address : (000) (000) (000) (000)_

Note: This option does not display when Hostlist is enabled from the ConnectMode prompt (see Connect Mode on page 45 for more information).

Remote Port

You must set the remote TCP port number for the unit to make outgoing connections. This parameter defines the port number on the target host to which a connection is attempted.

Remote Port (0) ? _

To connect an ASCII terminal to a host using the unit for login purposes, use the remote port number 23 (Internet standard port number for Telnet services).

Note: This option does not display when Hostlist is enabled from the ConnectMode prompt (see Connect Mode on page 45 for more information).

Page 54: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

7: Setup Mode: Channel Configuration

xPico® 110 Wired Device Server Module User Guide 54

DisConnMode

This setting determines the conditions under which the unit will cause a network connection to terminate.

DisConnMode (00) ? _

Notes:

In DisConnMode (Disconnect Mode), Modem Control In drop either drops the connection or is ignored.

All bit positions in the table that are blank represent “don’t care” bits, for that particular option, which can be set to either a 0 or 1 value.

Table 7-9. Disconnect Mode Options

Disconnect Mode Option 7 6 5 4 3 2 1 0 Disconnect when Modem Control In is not asserted (6) 1

Ignore Modem Control In 0

Telnet Com Port Cntrl and terminal type setup (1) 1

Channel (port) password (2) 1

Hard disconnect (3) 0

Disable hard disconnect 1

State LED off with connection (4) 1

Disconnect with EOT (^D) (5) 1

(1) The Telnet Com Port Control feature is used in conjunction with Com Port Redirector. The unit sends the Terminal Type upon an outgoing connection.

(2) A password is required for a connection to the serial port from the network.

(3) The TCP connection closes even if the remote site does not acknowledge the disconnection.

(4) When there is a network connection to or from the serial port, the state LED turns off instead of blinking.

(5) When Ctrl+D or Hex 04 is detected, the connection is dropped. Both Telnet Com Port Cntrl and Disconnect with EOT must be enabled for Disconnect with EOT to function properly. Ctrl+D is only detected going from the serial port to the network.

(6) When Modem Control In transitions from a high state to a low state, the network connection to or from the serial port drops.

Page 55: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

7: Setup Mode: Channel Configuration

xPico® 110 Wired Device Server Module User Guide 55

Flush Mode (Buffer Flushing)

Using this parameter, you can control line handling and network buffers with connection startup and disconnect.

FlushMode (00) ? _

You can also select between two different packing algorithms.

Note: All bit positions in the table that are blank represent “don’t care” bits, for that particular option, which can be set to either a 0 or 1 value.

Table 7-10. Flush Mode Options

Function 7 6 5 4 3 2 1 0 Input Buffer (Serial to Network)

Clear with a connection initiated from the device to the network 1

Clear with a connection initiated from the network to the device 1

Clear when the network connection to or from the device is disconnected 1

Output Buffer (Network to Serial)

Clear with a connection initiated from the device to the network 1

Clear with a connection initiated from the network to the device 1

Clear when the network connection to or from the device is disconnected 1

Alternate Packing Algorithm (Pack Control)

Enable 1

Pack Control

The packing algorithms define how and when packets are sent to the network. The standard algorithm is optimized for applications in which the unit is used in a local environment, allowing for very small delays for single characters, while keeping the packet count low. The alternate packing algorithm minimizes the packet count on the network and is especially useful in applications in a routed Wide Area Network (WAN). Adjusting parameters in this mode can economize the network data stream.

Pack control settings are enabled in Flush Mode. Set this value to 00 if you do not need specific functions.

Note: All bit positions in the table that are blank represent “don’t care” bits, for that particular option, which can be set to either a 0 or 1 value.

Page 56: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

7: Setup Mode: Channel Configuration

xPico® 110 Wired Device Server Module User Guide 56

Table 7-11. Pack Control Options

Option 7 6 5 4 3 2 1 0 Packing Interval

Interval: 12ms 0 0

Interval: 52ms 0 1

Interval: 250ms 1 0

Interval: 5sec 1 1

Trailing Characters

None 0 0

One 0 1

Two 1 0

Send Characters

2-Byte Send Character Sequence 1

Send Immediately After Send chars 1

Packing Interval Packing Interval defines how long the unit should wait before sending accumulated characters. This wait period is between successive network segments containing data. For alternate packing, the default interval is 12 ms.

Trailing Characters In some applications, CRC, Checksum, or other trailing characters follow the end-of-sequence character; this option helps to adapt frame transmission to the frame boundary.

Send Characters If 2-Byte Send Character Sequence is enabled, the unit interprets the sendchars as a 2-

byte sequence; if this option is not enabled, the unit interprets them independently.

If Send Immediately After Characters is not set, any characters already in the serial buffer are included in the transmission after a "transmit" condition is found. If this option is set, the unit sends immediately after recognizing the transmit condition (sendchar or timeout).

Note: A transmission might occur if status information needs to be exchanged or an acknowledgment needs to be sent.

Page 57: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

7: Setup Mode: Channel Configuration

xPico® 110 Wired Device Server Module User Guide 57

DisConnTime (Inactivity Timeout)

Use this parameter to set an inactivity timeout. The unit drops the TCP connection to the local port if there is no activity on the serial line before the set time expires. Enter time in the format mm:ss, where m is the number of minutes and s is the number of seconds.

DisConnTime (00:00) ?:

To disable the inactivity timeout, enter 00:00. Range is 0 (disabled) to 5999 seconds (99 minutes, 59 seconds). Default is 0.

Send Characters

Enter up to two characters in hexadecimal representation in sendchar.

SendChar 1 ( 0) ? _

SendChar 2 ( 0) ? _

If the unit receives a character on the serial line that matches one of these characters, it sends the character immediately, along with any awaiting characters, to the TCP connection. This action minimizes the response time for specific protocol characters on the serial line (for example, ETX, EOT). Setting the first sendchar to 00 disables the recognition of the characters. Alternatively, the unit can interpret two characters as a sequence (see Pack Control on page 55).

Telnet Terminal Type

This parameter displays only if you enabled the terminal type option in Disconnect Mode. With this option enabled, you can use the terminal name for the Telnet terminal type. Enter only one name.

With terminal type option enabled, the unit also reacts to the EOR (end of record) and binary options, useful for applications like terminal emulation to IBM hosts.

Channel (Port) Password

This parameter appears only if the channel (port) password option is enabled in Disconnect Mode. With this option enabled, you can set a password on the serial port.

Page 58: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

xPico® 110 Wired Device Server Module User Guide 58

8. Setup Mode: Advanced Settings

Expert Settings (Option 5)

Note: You can change the Enable alternate MAC setting using telnet or serial connections only. It is not available through the Web Manager.

CAUTION: Only an expert should change these parameters. You must definitely know the consequences the changes might have.

Figure 8-1. Expert Settings

TCP Keepalive time in s (1s - 65s; 0s=disable): (45) ?

ARP Cache timeout in s (0s - 600s) : (600) ?

CPU performance (0=Regular, 1=Low, 2=High): (0) ?

Disable Monitor Mode @ bootup (N) ?

HTTP Port Number : (80) ?

MTU Size (512 - 1400): (1400) ?

TCP Re-transmission Timeout (500 - 4000) (ms): (500) ?

Enable alternate MAC (N) ?

Ethernet connection type: (0) ?

The default settings are listed below:

TCP Keepalive time in s (1s – 65s; 0s=disable)

45

ARP Cache timeout in s (0s – 600s; 0s=disable)

600

CPU Performance Regular Disable Monitor Mode @ bootup No HTTP Port Number (1-65535)

80

MTU Size (512 – 1400) 0 (resulting in an operational value of 1400)

TCP Re-transmission Timeout 0 (resulting in an operational value of 500)

Enable alternate MAC No (OEM use only)

Ethernet connection type 0 (resulting in auto-negotiation)

Page 59: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

8: Setup Mode: Advanced Settings

xPico® 110 Wired Device Server Module User Guide 59

TCP Keepalive time in seconds This option allows you to change how many seconds the unit waits during a silent connection before attempting to see if the currently connected network device is still on the network. If the unit gets no response, it drops that connection.

TCP Keepalive time in s (1s – 65s; 0s=disable): (45)? _

ARP Cache timeout in seconds Whenever the unit communicates with another device on the network, it adds an entry into its ARP table. The ARP Cache timeout option allows you to define how many seconds (1-600) the unit will wait before timing out this table. Entering 0 disables this feature.

ARP Cache timeout in s (0s - 600s) : (600) ?

CPU Performance This option allows you to increase the CPU performance required to use the higher baud rates on the serial interface (460800 bps and 921600 bps). The standard CPU performance mode supports up to 230400 bps.

CPU performance (0=Regular, 1=Low, 2=High): (0) ?

Notes:

If a baud rate of 460 Kbps or 920 Kbps is set and the high performance mode is disabled, the operation of the serial channel would be out of the specified error tolerance, thereby leading to inconsistent speed settings on the two ends of the serial channel.

Increasing CPU clock speed consumes more power and generates more heat. This reduces the maximum operating temperature specification. See the appropriate product brief for details.

Disable Monitor Mode at bootup This option allows you to disable all entries into Monitor Mode during startup, except for the ‘xxx’ sequence. This prevents entry using yyy, zzz, xx1, and yy1 key sequences (only during the bootup sequence). The default for Monitor Mode at bootup is N (No). (See 11 Monitor Mode.)

Disable Monitor Mode @ bootup (N) ? _

HTTP Port Number This option allows the configuration of the web server port number. The valid range is 1-65535. The default HTTP port number is 80.

HTTP Port Number : (80) ? _

Page 60: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

8: Setup Mode: Advanced Settings

xPico® 110 Wired Device Server Module User Guide 60

MTU Size The Maximum Transmission Unit (MTU) is the largest physical packet size a network can transmit for TCP and UDP. Enter between 512 and 1400 bytes. The default is 1400 bytes.

MTU Size (512 - 1400): (1400) ? _

TCP Re-Transmission Timeout The TCP Re-Transmission Timeout is the interval to wait for acknowledgement of transmitted TCP segments before re-transmitting them. Enter between 500 and 4000 ms. The default is 500 ms.

TCP Re-transmission Timeout (500 - 4000) (ms): (500) ?

Enable alternate MAC If necessary, enable the alternate MAC address (if specified in the OEM setup record).

Enable alternate MAC (N) ? _

Ethernet Connection Type The xPico 110 wired device server module allows for the Ethernet speed and duplex to be manually configured. Enter 0 for auto-negotiation (default). To select the speed and duplex, enter one of the following: 2 (10 MB/half duplex), 3 (10 MB/full duplex), 4 (100 MB/half duplex), or 5 (100 MB/full duplex).

Ethernet connection type: (0) ? _

Security Settings (Option 6)

Note: You can change security settings by means of Telnet or serial connections only, not on the Web Manager. We recommend that you set security over the dedicated network or over the serial setup to prevent eavesdropping.

CAUTION: Disabling both Telnet Setup and Port 77FE will prevent users from accessing the setup menu from the network. Disabling Port 77FE also disables the Web from configuring the device.

Select 7 to configure security settings.

Figure 8-2. Security Settings

Disable SNMP (N) ?

SNMP Community Name (public):

Disable Telnet Setup (N) ?

Page 61: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

8: Setup Mode: Advanced Settings

xPico® 110 Wired Device Server Module User Guide 61

Disable TFTP Firmware Update (N) ?

Disable Port 77FEh (N) ?

77FEh Access Mode (0=Read & Write, 1=Read Only): (0) ? _

Disable Web Server (N) ?

Disable Web Setup (N) ?

Disable ECHO ports (Y) ?

Enable Encryption (N) ?

Enable Enhanced Password (N) ?

Disable Port 77F0h (N) ?

Disable SNMP This setting allows you to disable the SNMP protocol on the unit for security reasons.

Disable SNMP (N) ? _

SNMP Community Name The SNMP Community Name is a required field for NMS to read or write to a device. Enter a string of 1 to 13 characters.

SNMP Community Name (public): _

The default entry is public. The current value is displayed in parentheses.

Disable Telnet Setup Note: If you choose to disable this option, keep in mind that disabling both Telnet Setup and Port 77FE will prevent users from accessing the setup menu from the network.

This setting defaults to the N (No) option. The Y (Yes) option disables access to Setup Mode by Telnet (port 9999). It only allows access locally using the web pages and the unit serial port.

Disable Telnet Setup (N) ? _

Disable TFTP Firmware Upgrade This setting defaults to the N (No) option. The Y (Yes) option disables the use of TFTP to perform network firmware upgrades. With this option, you can download firmware upgrades over the serial port using DeviceInstaller’s Recover Firmware procedure. (See 10 Firmware Upgrades.)

Disable TFTP Firmware Update (N) : _

Page 62: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

8: Setup Mode: Advanced Settings

xPico® 110 Wired Device Server Module User Guide 62

Disable Port 77FE (Hex) Note: If you choose to disable this option, keep in mind that disabling both Telnet Setup and Port 77FE will prevent users from accessing the setup menu from the network.

Port 77FE is a setting that allows DeviceInstaller, Web Manager, and custom programs to configure the unit remotely. You may wish to disable this capability for security purposes.

Disable Port 77FEh (N) ? _

The default setting is the N (No) option, which enables remote configuration. You can configure the unit by using DeviceInstaller, web pages, Telnet, or serial configuration.

The Y (Yes) option disables remote configuration and web sites.

Note: The Y (Yes) option disables many of the GUI tools for configuring the unit, including the embedded Web Manager tool.

77FEh Access Mode Configuring this setting is available if port 77FE is enabled. This option will not be listed if port 77FE is disabled.

Set 0 for Read & Write mode, and 1 for Read Only mode. Default value of this setting is Read-Write(0).

If access mode is Read-only, then read operation can be done through port 77FE, if Read-Write access is selected, then both read and write of data can be done through port 77FE.

77FEh Access Mode (0=Read & Write, 1=Read Only): (0) ? _

Disable Web Server This setting defaults to the N (option). The Y (Yes) option disables the web server.

Disable Web Server (N) ? _

Disable Web Setup The Y (Yes) option disables configuration using the Web Manager. This setting defaults to the N (option).

Disable Web Setup (N) ? _

Disable ECHO Ports This setting controls whether port 7 echoes characters it receives.

Disable ECHO ports (Y) ? _

Page 63: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

8: Setup Mode: Advanced Settings

xPico® 110 Wired Device Server Module User Guide 63

Enable Encryption Rijndael is the block cipher algorithm chosen by the National Institute of Science and Technology (NIST) as the Advanced Encryption Standard (AES) to be used by the US government. The xPico 110 wired device server module supports 128-, 192-, and 256-bit encryption key lengths.

Note: Configuring encryption should be done through a local connection to the serial port of the xPico 110 wired device server module, or via a secured network connection. Initial configuration information, including the encryption key, is sent in clear text over the network.

To configure AES encryption on the xPico 110 wired device server module:

Enable Encryption (N) ? Y

Key length in bits (0): 128

Change Key (N) ? Y

Enter Key: **-**-**-**-**-**-**-**-**-**-**-**-**-**-**-**

1. When prompted to enable encryption, select Y.

2. When prompted, enter the encryption key length. The xPico 110 wired device server module supports 128-, 192-, and 256-bit encryption key lengths.

3. When prompted to change keys, select Y.

4. At the Enter Keys prompt, enter your encryption key. The encryption keys are entered in hexadecimal. The hexadecimal values are echoed as asterisks to prevent onlookers from seeing the key. Hexadecimal values are 0-9 and A-F. For a 128-bit key length, enter 32 hexadecimal characters. For a 192-bit key length, enter 48 hexadecimal characters. For a 256-bit key length, enter 64 hexadecimal characters

5. Continue pressing Enter until you return to the Change Setup menu.

6. From the Change Setup menu, select option 9 to save and exit.

Encryption only applies to the port selected for data tunneling (default 10001 for Channel 1 and 10002 for Channel 2), regardless of whether you are using TCP or UDP.

Generally, one of these situations applies:

Encrypted xPico-to-xPico 110 wired device server module communication. Be sure to configure both modules with the same encryption key.

Third-party application to xPico 110 wired device server module-encrypted communication: xPico 110 wired device server module uses standard AES encryption protocols. To communicate successfully, products and applications on the peer side must use the same protocols and the same encryption key as the xPico 110 wired device server module.

Page 64: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

8: Setup Mode: Advanced Settings

xPico® 110 Wired Device Server Module User Guide 64

Lantronix Secure Com Port Redirector provides an encrypted connection from Windows-based applications to the xPico 110 wired device server module. Information about SCPR is at www.lantronix.com/device-networking/utilities-tools/scpr. A 30-day trial version of SCPR is available.

Note: Developers can license the Lantronix Encryption Library Suite. See www.lantronix.com/device-networking/utilities-tools.

Enable Enhanced Password The Enhanced Password setting allows you to set a password of up to 16 characters for protecting Telnet and Web Page access. We recommend that you select the Y (Yes) option and enable the enhanced password setting.

Avoid using either the 4 character basic password setting or no password at all as they are not secure options.

Enable Enhanced Password (Y) ? _

Disable Port 77F0 (Hex) Port 77F0 is a setting that allows a custom application to query or set the eight xPico 110 wired device server module configurable pins when they are functioning as general purpose I/O (GPIO). You may want to disable this capability for security purposes. The default setting is the N (No) option, which enables GPIO control. The Y (Yes) option disables the GPIO control interface.

Disable Port 77F0h ? _

Default Settings (Option 7)

Select 7 to reset the unit’s Channel 1 and Channel 2 configuration and expert settings to the default settings. The server configuration settings for IP address, gateway IP address, and netmask remain unchanged. The configurable pins’ settings also remain unchanged. The specific settings that this option changes are listed below:

Channel 1 and Channel 2 Configuration Defaults

Baudrate 9600

I/F Mode 4C (1 stop bit, no parity, 8 bit, RS-232C)

Flow 00 Note: Flow control option only available for Channel 1 configuration.

Port number 10001 for Channel 1 10002 for Channel 2

Connect Mode C0 (always accept incoming connection; no active connection startup)

Page 65: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

8: Setup Mode: Advanced Settings

xPico® 110 Wired Device Server Module User Guide 65

Send '+++' in Modem Mode Enabled

Show IP addr after 'RING' Enabled

Auto increment source port Disable

Hostlist retry counter 3

Hostlist retry timeout 250 (msec)

Start character for serial channel 1 (or 2) 0x0D (CR)

All other parameters 0

Expert Settings Defaults

TCP Keepalive time in s 45

ARP Cache timeout in s 600

CPU Performance 0 (Regular)

Monitor Mode @ bootup Enabled

HTTP Port Number (1-65535) 80

MTU Size (512 – 1400) 0 (resulting in an operational value of 1400)

TCP Re-transmission timeout (ms) 500 (msec)

Alternate MAC Disabled (for OEM use only)

Ethernet Connection Type 0 (auto-negotiate)

Security Settings Defaults

Disable SNMP No

SNMP community name public

Disable Telnet setup No

Disable TFTP Firmware Update No

Disable Port 77FEh No

77FEh Access Mode 0 (Read & Write)

Disable Web Server No

Disable Web Setup No

Disable ECHO ports Yes

Enable Encryption No

Enable Enhanced Password No

Disable Port 77F0h No

Page 66: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

9: GPIO Interface

xPico® 110 Wired Device Server Module User Guide 66

9. GPIO Interface

Configurable Pins

The xPico 110 wired device server module has eight pins (CP1-8) that you can configure for General Purpose I/O (GPIO).

Note: You can also configure the pins for serial port control lines, such as hardware control, modem control (CTS, RTS, DTR, and DCD), and diagnostic outputs to LED, using DeviceInstaller.

You can use these GPIO pins to control devices such as relays, servers, lights, monitor switches, sensors, and even processes such as data transfer.

You can set the functions for the eight pins independently and in any combination. The initial directions (input/output) and active levels (active low or high) at boot up can also be configured through 77FE, for example, by using DeviceInstaller.

This chapter describes how the directions, active levels, and states can be dynamically controlled and probed through special port 77F0.

The configurable pins default configuration is:

Function: General Purpose Input

Active Level: Active Low

Features TCP and UDP can be used.

The protocol supports up to 32 GPIO for future products.

Function configuration can be retrieved.

Input or output selection can be retrieved and controlled.

Active low or high selection can be retrieved and controlled.

Active or inactive selection can be retrieved and controlled.

77F0 can be disabled.

Every change of state (active/inactive) requires a command over TCP or UDP, and thus is not very fast. If you use this port for data transfer, the throughput is low, usually up to 1 Kbps.

Page 67: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

9: GPIO Interface

xPico® 110 Wired Device Server Module User Guide 67

Control Protocol

The GPIO control protocol is a simple, proprietary protocol.

Guidelines The GPIO control protocol is described from the PC side. Send means from PC to xPico 110 wired device server module. Response comes from xPico 110 wired device server module to PC.

The protocol allows for control of up to 32 GPIOs. How many are actually available depends on the product. xPico 110 wired device server module has only eight.

The parameters are four bytes long and represent GPIOs 0-31, with GPIO0 in bit 0 of the first byte (Little Endian). Parameter bits for configurable pins not configured as GPIOs are undefined for Get commands and ignored on Set commands.

Every command consists of nine bytes: one command type of one byte and two parameters of four bytes each.

Command Parameter 1 Parameter 2 0 1 2 3 4 5 6 7 8

On some commands, one or all parameters are ignored.

For UDP, command type and parameters need to be in the same datagram.

Responses to valid commands are always five bytes long, consisting of the returned command byte and as parameters in the current or updated values. In case of an invalid command, only one byte with value 0FFh is returned.

Command Parameter 1 0 1 2 3 4

When sending a command (TCP and UDP), wait for the response before sending the next command.

Commands Byte 0 Command Types

10h Get functions

11h Get directions (input or output)

12h Get active levels (high active or low active)

13h Get current states (active or not active)

19h Set directions

1Ah Set active levels

1Bh Set current states

There is no Set functions command. Since the pin’s function depends on the hardware in which the xPico 110 wired device server module is embedded, that configuration is only allowed using 77FE. Settings changed by any of the Set commands are not stored and are lost when the unit is powered down or rebooted.

Page 68: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

9: GPIO Interface

xPico® 110 Wired Device Server Module User Guide 68

Command 10h, Get Functions

Send: No parameters

Response: 1 parameter Bytes 1-4: Functions Bit X 1 means general purpose I/O available to the user. 0 means dedicated function (e.g., serial flow control, diagnostics) for

configurable pin X.

Command 11h, Get Directions

Send: No parameters

Response: 1 parameter Bytes 1-4: Directions Bit X 1 means GPIO X is an output. 0 means it is an input.

Command 12h, Get Active Levels

Send: No parameters

Response: 1 parameter Bytes 1-4: Active levels Bit X 1 means GPIO X is active low (0V when active, 3.3V when inactive). 0 means it is active high (3.3V when active, 0V when inactive).

Command 13h, Get Current States

Send: No parameters

Response: 1 parameter Bytes 1-4: States Bit X 1 means GPIO X is active 0 means it is inactive.

Page 69: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

9: GPIO Interface

xPico® 110 Wired Device Server Module User Guide 69

Command 19h, Set Directions

Send: 2 parameters Bytes 1-4: Mask Bit X 1 means the direction for GPIO X will be updated with the value in the

second parameter. 0 means the direction for that GPIO will not change. Bytes 5-8: New Directions Bit X 1 means GPIO X will become an output. 0 means it will become an input. Response: 1 parameter Bytes 1-4: The updated directions

Command 1Ah, Set Active Levels

Send: 2 parameters Bytes 1-4: Mask Bit X 1 means the direction for GPIO X will be updated with the value in the

second parameter. 0 means the active type for that GPIO will not change. Bytes 5-8: New Active Levels Bit X 1 means GPIO X will become active low. 0 means it will become active high. Response: 1 parameter Bytes 1-4: Updated active levels

Command 1Bh, Set States

Send: 2 parameters Bytes 1-4: Mask Bit X 1 means the state for GPIO X will be updated with the value in the

second parameter. 0 means the state for that GPIO will not change. Bytes 5-8: New States Bit X 1 means GPIO X will become active. 0 means it will become inactive. Response: 1 parameter Bytes 1-4: Updated states

Page 70: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

9: GPIO Interface

xPico® 110 Wired Device Server Module User Guide 70

Examples

Example 1: PC sends command 10h to find out which configurable pins are available as GPIO.

PC -> xPico 110: 10h, 00h, 00h, 00h, 00h, 00h, 00h, 00h, 00h xPico 110 -> PC: 10h, 03h, 00h, 00h, 00h

Command details:

10h = command 10h 00h, 00h, 00h, 00h = ignored 00h, 00h, 00h, 00h = ignored

Response details:

10h = response to command 10h 03h, 00h, 00h, 00h =

bits 0 and 1 are 1 →CP1 and CP2 are configured as GPIOs. bit 2 is 0 → CP3 is configured as either serial control or diagnostics. The other bits are ignored because there are only eight configurable pins on the xPico 110.

Example 2: PC sends command 1Bh to change the current states of GPIO 0 and 1.

PC -> xPico 110: 1Bh, 01h, 00h, 00h, 00h, 00h, 00h, 00h, 00h xPico 110 -> PC: 1Bh, 05h, 00h, 00h, 00h

Command details:

1Bh = command 1Bh 01h, 00h, 00h, 00h = the mask that determines which GPIOs will be changed.

bit 0 is 1 → GPIO0 will be changed. bit 1 is 0 → GPIO1 will remain the same.

00h, 00h, 00h, 00h = the new states

bit 0 is 0 → GPIO0 will become 0. bit 1 is ignored since it is masked out.

Response details:

1Bh = response to command 1Bh 05h, 00h, 00h, 00h =

bit 0 is 1 → GPIO0 = 1 bit 1 is 0 → GPIO1 = 0 bit 2 is 1 → GPIO2 = 1 The other bits are ignored because there are only eight configurable pins on the xPico 110.

Page 71: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

xPico® 110 Wired Device Server Module User Guide 71

10. Firmware Upgrades

Obtaining Firmware

You can obtain the most up-to-date firmware and release notes for the unit from the Lantronix web site (www.lantronix.com/support/downloads) or by using anonymous FTP (ftp.lantronix.com/pub).

Reloading Firmware

There are several ways to update the unit's internal operational code (*.ROM): using DeviceInstaller (the preferred way), using TFTP, or using the serial port. You can also update the unit's internal Web interface (*.COB) using TFTP or DeviceInstaller.

Here are typical names for those files. Check the Lantronix web site for the latest versions and release notes.

Table 10-1. Firmware Files

ROM File COB

xpico110_61105.rom xpico110_webm_20011.cob

Please refer to the DeviceInstaller online Help for information about reloading firmware using DeviceInstaller. The other methods are discussed below.

Using TFTP: Graphical User Interface To download new firmware from a computer:

1. Use a TFTP client to put a binary file to the unit (*.ROM to upgrade the unit's internal operational code and *.COB to upgrade its internal web interface).

Note: TFTP requires the .rom (binary) version of the unit's internal operational code.

2. In the Host field, enter the IP address of the unit being upgraded.

3. In the Port field, enter 69.

4. Enter the full path of the firmware file in the Local File field.

5. In the Remote File field, enter the current internal operational code or WEB1 to WEB6 for the internal web interface.

Page 72: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

10: Firmware Upgrades

xPico® 110 Wired Device Server Module User Guide 72

Figure 10-1. TFTP Window

6. Click the Put button to transfer the file to the unit. The unit performs a power reset after the firmware has been loaded and stored.

After the firmware has been loaded and stored, which takes approximately 8 seconds to complete, the unit performs a power reset.

Using TFTP: Command Line Interface To download new firmware from a computer:

1. Enter the following from a TFTP command line interface:

tftp –i <ip address> put <local filename> <destination file name>

The following examples demonstrate the TFTP command sequence to download the .rom file and the .cob file:

tftp –i 192.168.1.111 put xpico110_61105 6X

tftp –i 192.168.1.111 put xpico110_webm_20011.cob WEB1

Page 73: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

10: Firmware Upgrades

xPico® 110 Wired Device Server Module User Guide 73

Recovering the Firmware Using the Serial Port and DeviceInstaller If for some reason the firmware is damaged, you can recover the firmware file by using DeviceInstaller to download the *.ROM file over the serial port.

To recover firmware:

1. Start the DeviceInstaller® application. If your PC has more than one network adapter, a message displays. Select an adapter and click OK.

2. From the Tools menu, select Advanced/Recover Firmware. The Serial Port Firmware Upgrade window displays.

3. For Port on PC, enter the COM port on the PC that is connected to the serial port of the Lantronix unit.

4. For Device Model, be sure the appropriate xPico 110 module is shown (xPico 110).

5. For Firmware File, click the Browse button and go to the location where the firmware file resides.

Note: Make sure the xPico 110 wired device server module on which you are recovering firmware is connected to this selected port on your PC.

6. Click OK to download the file.

7. When prompted, reset the device. Status messages and a progress bar at the bottom of the screen show the progress of the file transfer. When the file transfer completes, the message “Successful, Click OK to Close” appears.

8. Click the OK button to complete this procedure.

Note For more information, see Recovering Firmware in the DeviceInstaller online Help.

Page 74: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

xPico® 110 Wired Device Server Module User Guide 74

11. Monitor Mode Monitor Mode is a command-line interface used for diagnostic purposes. There are two ways to enter Monitor Mode: locally using the serial port or remotely using the network.

Entering Monitor Mode Using the Serial Port

To enter Monitor Mode locally:

1. Follow the same steps used for setting the serial configuration parameters (see Serial Port on page 39).

2. Instead of typing three x keys, however:

3. Type zzz (or xx1) to enter Monitor Mode with network connections.

4. Type yyy (or yy1) to enter Monitor Mode without network connections. A 0> prompt indicates that you have successfully entered Monitor Mode.

Entering Monitor Mode Using the Network Port

To enter Monitor Mode using a Telnet connection:

1. Establish a Telnet session to the configuration port (9999). The following appears:

MAC address DC82F6000119

Software version V6.11.0.5RC1 (161006) XPICO-SMT

AES library version 1.8.2.1

Press Enter for Setup Mode

2. Type M (upper case).

A 0> prompt indicates that you have successfully entered Monitor Mode.

Monitor Mode Commands The following commands are available in Monitor Mode. Many commands have an IP address as an optional parameter (xxx.xxx.xxx.xxx). If you enter the IP address, the command is applied to another unit with that IP address. If you do not enter the IP address, the command is executed locally.

Note: All commands must be in capital letters. Responses to some of the commands are in Intel Hex format.

Page 75: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

11: Monitor Mode

xPico® 110 Wired Device Server Module User Guide 75

Table 11-1. Monitor Mode Commands

Command Command Name Function

VS x.x.x.x Version Queries software header record (16 bytes) of unit with IP address x.x.x.x.

GC x.x.x.x Get Configuration Gets configuration of unit with IP address x.x.x.x as hex records (120 bytes).

SC x.x.x.x Send Configuration Sets configuration of unit with IP address x.x.x.x from hex records.

PI x.x.x.x Ping Pings unit with IP address x.x.x.x to check device status.

AT ARP Table Shows the unit’s ARP table entries.

TT TCP Connection Table

Shows all incoming and outgoing TCP connections.

NC Network Connection Shows the unit’s IP address, gateway, subnet mask, and DNS server.

RS Reset Resets the unit’s power.

QU Quit Exits diagnostics mode.

G0, G1, ....,Ge, Gf Get configuration from memory page

Gets a memory page of configuration information from the device.

S0, S1,...,Se, Sf Set configuration to memory page

Sets a memory page of configuration information on the device.

GM Get MAC address Shows the unit's 6-byte MAC address.

SS Set Security record Sets the Security record without the encryption key and length parameters. The entire record must still be written, but the encryption-specific bytes do not need to be provided (they can be null since they are not overwritten).

SA Scan Initiates a wireless scan if the wireless interface is enabled. Reports any stations found, including BSSID, SSID, and RSSI. If SA is followed by a string, the string is used to filter SSIDs before reporting. If the BSS does not broadcast its SSID, only the BSSID and RSSI are returned.

NS Network Status Reports the network interfaces’ statuses. Includes potentially negotiated parameters like speed/duplex for Ethernet or BSSID, encryption, authentication for wireless interfaces.

co Set IP address, hostbits, gateway , and DNS server IP

Example: co 192.168.0.10 8 192.168.0.1 10001 192.168.1.10 with 192.168.0.10 = IP address of the xPico 110 8 = number of hostbits

Page 76: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

11: Monitor Mode

xPico® 110 Wired Device Server Module User Guide 76

Command Command Name Function

192.168.0.1 = gateway IP address 10001 = port number of the xPico 110 Channel 1 192.168.1.10 = IP address of the DNS Server The xPico 110 wired device server module stores the setup and performs a reset. It sends an X before the reset if the command was OK.

VN Query full firmware version

This command queries and displays full firmware version in readable string format.

WC Flash write count This command shows serial flash write counts, valid on serial flash products.

Note: Entering any of the commands listed above generates one of the following command response codes:

Table 11-2. Command Response Codes

Response Meaning

0> OK; no error

1> No answer from remote device

2> Cannot reach remote device or no answer

8> Wrong parameter(s)

9> Invalid command

Page 77: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

xPico® 110 Wired Device Server Module User Guide 77

12. Troubleshooting This chapter discusses how you can diagnose and fix errors quickly without having to contact a dealer or Lantronix. It helps to connect a terminal to the serial port while diagnosing an error to view summary messages that may display. When troubleshooting, always ensure that the physical connections (power cable, network cable, and serial cable) are secure.

Note: Some unexplained errors might be caused by duplicate IP addresses on the network. Make sure that your unit's IP address is unique.

When troubleshooting the following problems, make sure that the xPico 110 wired device server module is powered up. Confirm that you are using a good network connection.

Problems and Error Messages

Problem/Message Reason Solution

When you issue the ARP –S command in Windows, the "ARP entry addition failed: 5" message displays.

Your currently logged-in user does not have the correct rights to use this command on this PC.

Have someone from your IT department log you in with sufficient rights.

When you attempt to assign an IP address to the unit by the ARP method, the "Press Enter to go into Setup Mode" error "(described below) message displays. Now when you Telnet to the device server, the connection fails.

When you Telnet to port 1 on the device server, you are only assigning a temporary IP address. When you Telnet into port 9999 and do not press Enter quickly, the device server reboots, causing it to lose the IP address.

Telnet back to Port 1. Wait for it to fail, then Telnet to port 9999 again. Make sure you press Enter quickly.

When you Telnet to port 9999, the "Press Enter to go into Setup Mode" message displays. However, nothing happens when you press Enter, or your connection is closed.

You did not press Enter quickly enough. You only have 5 seconds to press Enter before the connection is closed.

Telnet to port 9999 again, but press Enter as soon as you see the "Press Enter to go into Setup Mode" message.

When you Telnet to port 1 to assign an IP address to the device server, the Telnet window does not respond for a long time.

You may have entered the Ethernet address incorrectly with the ARP command.

Confirm that the Ethernet address that you entered with the ARP command is correct. The Ethernet address may only include numbers 0-9 and letters A-F. In Windows and usually in Unix, the segments of the Ethernet address are separated by dashes. In some forms of Unix, the Ethernet address is segmented with colons.

Page 78: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

12: Troubleshooting

xPico® 110 Wired Device Server Module User Guide 78

Problem/Message Reason Solution

The IP address you are trying to assign is not on your logical subnet.

Confirm that your PC has an IP address and that it is in the same logical subnet that you are trying to assign to the device server.

The device server may not be plugged into the network properly.

Make sure that the Link LED is lit. If the Link LED is not lit, then the device server is not properly plugged into the network.

When you try to assign an IP with DeviceInstaller, you get the following : "No response from device! Verify the IP, Hardware Address and Network Class. Please try again."

The cause is most likely one of the following: The hardware address you specified is incorrect. The IP address you are trying to assign is not a valid IP for your logical subnet. You did not choose the correct subnet mask.

Double-check the parameters that you specified. Note: You cannot assign an IP address to a device server through a router.

The device server is not communicating with the serial device to which it is attached.

The most likely reason is the wrong serial settings were chosen.

The serial settings for the serial device and the device server must match. The default serial settings for the device server are RS-232, 9600 baud, 8 character bits, no parity, 1 stop bit, no flow control.

When you try to enter the setup mode on the device server using the serial port, you get no response.

The issue is most likely something covered in the previous problem, or possibly, you have Caps Lock on.

Double-check everything in the problem above. Confirm that Caps Lock is not on.

You can ping the device server, but not Telnet to the device server on port 9999.

There may be an IP address conflict on your network You are not Telneting to port 9999. The Telnet configuration port (9999) is disabled within the device server security settings.

Turn the device server off and then issue the following commands at the DOS prompt of your computer: ARP -D X.X.X.X (X.X.X.X is the IP of the device server). PING X.X.X.X (X.X.X.X is the IP of the device server). If you get a response, then there is a duplicate IP address on the network. If you do not get a response, use the serial port to verify that Telnet is not disabled.

Page 79: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

12: Troubleshooting

xPico® 110 Wired Device Server Module User Guide 79

Problem/Message Reason Solution

The device server appears to be set up correctly, but you are not communicating with your device attached to the device server across the network.

If you are sure that the serial port setting is correct, then you may not be connecting to the correct socket of the device server. Another possibility is that the device server is not set up correctly to make a good socket connection to the network.

You can check to see whether there is a socket connection to or from the device server by checking the state of CPx, if one of the CPs has been configured for Serial Channel Status LED functionality. If the state of CPx is blinking consistently, then there is a good socket connection. If the state of CPx is low, use the Connect Mode option C0 for making a connection to the device server from the network. Use Connect Mode option C1 or C5 for a connection to the network from the device server. See the full list of Connect Mode options in Connect Mode.

When connecting to the Web Manager within the device server, the "No Connection With The Device Server" message displays.

Your computer is not able to connect to port 30718 (77FEh) on the device server.

Make sure that port 30718 (77FEh) is not blocked with any router that you are using on the network. Also, make sure that port 77FEh is not disabled within the Security settings of the device server.

Page 80: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

xPico® 110 Wired Device Server Module User Guide 80

A: Technical Support Lantronix offers many resources to support our customers and products at http://www.lantronix.com/support. For instance, ask a question, find firmware downloads, access the FTP site and search through tutorials, FAQs, bulletins, warranty information, extended support services, and product documentation.

To contact technical support or sales, look up your local office at http://www.lantronix.com/about/contact.html. When you report a problem, please provide the following information:

Your name, company name, address, and phone number

Lantronix product and model number

Lantronix MAC number or serial number

Firmware version and current configuration

Description of the problem

Status of the unit when the problem occurred (please try to include information on user and network activity at the time of the problem).

Page 81: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

xPico® 110 Wired Device Server Module User Guide 81

B: Binary to Hexadecimal Conversions Many of the unit’s configuration procedures require assembling a series of options (represented as bits) into a complete command (represented as a byte). Convert the resulting binary value to a hexadecimal representation.

Converting Binary to Hexadecimal

Following are two simple ways to convert binary numbers to hexadecimals.

Conversion Table Hexadecimal digits have values ranging from 0 to F, which are represented as 0-9, A (for 10), B (for 11), etc. To convert a binary value (for example, 0100 1100) to a hexadecimal representation, the upper and lower four bits are treated separately, resulting in a two-digit hexadecimal number (in this case, 4C). Use the following table to convert values from binary to hexadecimal.

Decimal Binary Hex 0 0000 0 1 0001 1 2 0010 2 3 0011 3 4 0100 4 5 0101 5 6 0110 6 7 0111 7 8 1000 8 9 1001 9

10 1010 A 11 1011 B 12 1100 C 13 1101 D 14 1110 E 15 1111 F

Scientific Calculator Another simple way to convert binary to hexadecimals is to use a scientific calculator, such as the one available on Windows’ operating systems. For example:

1. On the Windows’ Start menu, click ProgramsAccessoriesCalculator.

2. On the View menu, select Scientific. The scientific calculator displays.

3. Select Bin (Binary), and type the number to convert.

Page 82: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

B: Binary to Hexadecimal Conversions

xPico® 110 Wired Device Server Module User Guide 82

4. Click Hex. The hexadecimal value displays.

Page 83: xPico 110 Wired Device Server Module User Guide - …...xPico® 110 Wired Device Server Module User Guide 3 Changes or modifications to this device not explicitly approved by Lantronix

xPico® 110 Wired Device Server Module User Guide 83

C: Compliance

RoHS, REACH and WEEE Compliance Statement

Please visit http://www.lantronix.com/legal/rohs/ for Lantronix's statement about RoHS, REACH and WEEE compliance.