• Pediatric trauma and resuscitations: high-stakes, low-frequency, quality of care difficult to assess
• There are few data exploring the relationship of simulation performance to performance on real patients
• The validity of the assessment of simulated performance as a surrogate for clinical performance needs further investigation
Background
• To compare time to performance of interventions in simulated to real patient cases
• n= 22 real patient cases and 11 simulated cases• No difference in TTI between simulated and clinical cases for obtain SAMPLE history,
circulation assessment, airway assessment, cardiorespiratory/O2 monitors placed, verbalize vital signs, O2 administration, order consults/imaging
• Simulation faster for IV placement and estimating/obtaining patient weight• Insufficient data for check dextrose, apply defibrillator pads, discharge defibrillator,
initiate airway RSI, insert endotracheal tube
• Design: Prospective comparative study• Setting: Level 1 pediatric emergency department• Inclusion: Real (R): level 1 & 2 triage patients ≤18 y/o
Simulated (S): in-situ simulated patients both in and outside of Yale
• Collection period: June 2013-present• Subjects: Interdisciplinary pediatric emergency teams• Assessments: Time-to-intervention (TTI) = elapsed time from
patient arrival (t0) to performance of intervention• Interventions assessed: obtain SAMPLE history, circulation
assessment, airway assessment, cardiorespiratory/O2 monitors placed, verbalize vital signs, place IV, estimate/obtain patient weight, O2 administration, order consults/imaging, check dextrose, apply defibrillator pads, discharge defibrillator, initiate airway RSI, insert endotracheal tube
Lucas Butler, Anup Agarwal MBBS, Jaewon Jang PhDc, Marc Auerbach MDYale School of Medicine
Yale-New Haven Children’s Hospital, Pediatric Emergency Medicine Department
Objective
Methods
ConclusionsAssessment Tool
Future Directions
Acknowledgements
• Performance in simulation is similar to real patient performance• TTI’s measured using novel iCODA checklist-stop watch application developed in
collaboration with Studiocode™
Limitations
Results
• Small sample size• Performance measured solely via TTI, without qualitative
assessment of performance• Confounding variables not measured—team size and
composition, case type
• These data support simulation performance assessment as surrogate for real patient performance
• Use of video review to improve data collection accuracy • Inclusion of qualitative data collection