UL 1389 UL 2075 UL 864 UL 2017 Additionally, all HAL Booths have been evaluated by a third-party professional engineering firm, Pressure Safety Inspectors (PSI), licensed in the following states. [AZ, CA, CO, FL, HI, ID, KS, KY, MA, MD, ME, MI, MN, NC, ND, NM, NV, OH, OK, OR, PA, SC, TN, TX, VT, WA] The HAL Booth has be reviewed and approved using the following codes and standards; NFPA 1, Chapter 38 NFPA 58 NFPA 30 NFPA 33 NFPA 70 International Fire Code (IFC) 2018 California Fire Code (CFC) International Mechanical Code (IMC) 510 Seismic analyst reports available for to Authority having Jurisdiction (AHJ) – performed by CA licensed PE COMP L I ANCE All HAL Booths have been evaluated by a Nationally Recognized Testing Laboratories(NRTL), Underwriters Laboratories, (UL). The HAL Booth is compliant with the following national standards: Interior Square Footage Exterior Dimensions Interior Dimensions Electrical Supply Air Flow Rate Sensor Set Points 170 SF 14'3" W x 13'8" L x 9'4.5" H *Additional height available 14'0" W x 12'2" L x 9'1.5" H *Additional height available 30-amp 208 - 240 VAC, 60Hz, 1-phase input power Base Rate Purge Rate 0-10% LEL 10-25% LEL 25%+ LEL Minimum Required 1500 CFM Minimum Required 3000 CFM Green Light Beacon + Base Flow Amber Light Beacon + Purge Flow Red Light Beacon(Flashing) + Purge Flow PRODUCTION SERIES / MODEL 170P 170P

Yellow Globe Simple Memo...A UL Listed, CID1 infrared (IR) sensor is included with each HAL Booth. Calibrations include but are not limited to: butane/propane, ethanol, pentane, hexane,

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Yellow Globe Simple Memo...A UL Listed, CID1 infrared (IR) sensor is included with each HAL Booth. Calibrations include but are not limited to: butane/propane, ethanol, pentane, hexane,

• UL 1389 • UL 2075 • UL 864 • UL 2017

Additionally, all HAL Booths have been evaluated by a third-party professional engineering firm, Pressure Safety Inspectors (PSI), licensed in the following states. [AZ, CA, CO, FL, HI, ID, KS, KY, MA, MD, ME, MI, MN, NC, ND, NM, NV, OH, OK, OR, PA, SC, TN, TX, VT, WA] The HAL Booth has be reviewed and approved using the following codes and standards;

• NFPA 1, Chapter 38 • NFPA 58 • NFPA 30 • NFPA 33 • NFPA 70 • International Fire Code (IFC) 2018 • California Fire Code (CFC) • International Mechanical Code (IMC) 510 • Seismic analyst reports available for to Authority having Jurisdiction (AHJ) – performed by CA licensed PE

C O M P L I A N C E

All HAL Booths have been evaluated by a Nationally Recognized Testing Laboratories(NRTL), Underwriters Laboratories, (UL). The HAL Booth is compliant with the following national standards:

Interior Square Footage

Exterior Dimensions

Interior Dimensions

Electrical Supply

Air Flow Rate

Sensor Set Points

170 SF

14'3" W x 13'8" L x 9'4.5" H *Additional height available

14'0" W x 12'2" L x 9'1.5" H *Additional height available

30-amp 208 - 240 VAC, 60Hz, 1-phase input power

Base Rate

Purge Rate

0-10% LEL

10-25% LEL

25%+ LEL

Minimum Required 1500 CFM

Minimum Required 3000 CFM

Green Light Beacon + Base Flow

Amber Light Beacon + Purge Flow

Red Light Beacon(Flashing) + Purge Flow

PRODUCTION

SER

IES /

MO

DEL

170P 170P

Page 2: Yellow Globe Simple Memo...A UL Listed, CID1 infrared (IR) sensor is included with each HAL Booth. Calibrations include but are not limited to: butane/propane, ethanol, pentane, hexane,

720.504.4726

@halextraction

5902 McIntyre Street Golden, CO 80403

extractionbooth.com

[email protected]

• Interior LED CID1 light fixtures• One access panel and utility penetration plate (UPP) is provided with each booth. The UPP contains 15 penetrations, fire rated

hole seals and, an air sealing gasket. This plate is designed for running utility lines to ancillary equipment outside of the booth. The modular design of the UPP assembly allows for various placements on any side of the booth.* Additional UPP assemblies available for purchase

• Equipment ground bus bar and cable for static discharge• CID2 remote operator switch.• CID1 emergency panic button for manual air purge during operations• Portable gas sensor

Standard door dimensions: 3’W x 7’H

Door is powder coated, has a 90-minute fire rating, is UL Listed, and is compliant with the American with Disabilities Act (ADA). Door contains a safety window and comes with emergency exiting hardware, door sweep, seal, and an automatic closure. The standard orientation of the door is Left Hand Reverse, (LHR), and is designed to open in the direction of egress. Right Hand Reverse and Double Door Options available.

A D D I T I O N A L S T A N D A R D I T E M S

STANDARD PACKAGEC O N T R O L S P A C K A G E

UL 508A listed panel with 7” Human Machine Interface Screen (HMI). Controls package includes a Standard Uninterrupted Power Supply (UPS) system that powers one overhead light, sensor, and alarms for two hours.

**Upgraded UPS system available to support full booth operation

Control panel features include alarm logs, data tracking, customized operator access levels, remote management and alerts, and five spare relays for various system states.

D O O R - C O N S T R U C T I O N

A UL Listed, CID1 infrared (IR) sensor is included with each HAL Booth. Calibrations include but are not limited to: butane/propane, ethanol, pentane, hexane, heptane, methanol, carbon dioxide, and oxygen. Each sensor is factory calibrated; a sensor calibration certificate is included with each unit. Sensor calibration kit is provided with each unit for routine maintenance.

A CID1 transmitter, with LCD screen, is connected to each sensor and displays the Lower Explosive Limit (LEL) value to operators inside the booth.

The gas detection system is interlocked with a CID2 tri-color light beacon and audible warning horn. The alarms alert operators when solvent levels have reached 10% and 25% of the LEL. The system state is also displayed on control panel HMI screen. ** Dual solvent monitoring package available ** UL 2075 sensor available

G A S D E T E C T I O N & A L A R M S

The HAL Booth is constructed from 18-gauge powder coated steel panels manufactured in the USA. Panels include pre-drilled slots for easy assembly and pre-punched conduit access holes. Panels are constructed to be a smooth cleanable surface for compliance with Good Manufacturing Practices (GMP). Modular designed allows for flexible configurations.

Flooring is not included; the booth must be installed on non-combustible concrete flooring. Anchoring hardware is provided for either internal or external anchoring.

Assembly hardware, one-hour fire rated caulk, and hazardous location conduit provided. Booth can be installed by customer; however, HAL offers complete installation and assembly services.

F I R E S U P P R E S S I O N

Fans operate at variable speeds based on US Patent #US10,232,286B1 assigned to HAL Extraction Technology Ltd.

CID1 explosion proof intake and exhaust fans included. Fans can accommodate up to 1.0 in.w.c of static pressure in each duct. Fans can accommodate additional HVAC components for heating, cooling, filtering, and odor mitigation.

Computational Fluid Dynamics (CFD) report has been performed by licensed professional engineer on plenum design. A CFD report, available for submittal to AHJ, demonstrates fans achieves 100 Linear Feet per Minute (LFM) capture velocity in the bottom 12" of the Booth.

F A N P A C K A G E

• The HAL booth accommodates existing water-based sprinkler system or a UL listed standalone system • Control system interlock functions with wet or dry fire suppression systems

** Dry powder and clean agent fire suppression packages available

CO

NT

AC

T U

S

P A N E L - C O N S T R U C T I O N