Upload
dangtuyen
View
214
Download
1
Embed Size (px)
Citation preview
YOUR VAPOR RECOVERY SOLUTIONS COMPANIES
WWW.OTACOMPRESSION.COMWWW.KIMARK.COM
PRESENTER INTRODUCTIONPRESENTER INTRODUCTIONS
WWW.OTACOMPRESSION.COMWWW.KIMARK.COM
SERVICE MATTERS
DEPENDABLE SERVICE
NO WORRIES! OTA’s/KIMARK’s HIGHLY QUALIFIED FIELD TECHNICIANS ARE AVAILABLE 24/7!
WWW.OTACOMPRESSION.COM
Rather the manufacturer come to
you and make the repairs?
Need reliable service technicians
trained on the equipment they are
servicing?
Are you
compliant?
WWW.OTACOMPRESSION.COMWWW.KIMARK.COM WWW.OTACOMPRESSION.COMWWW.KIMARK.COM
SERVICE MATTERS
RELIABLE SERVICE
OTA provides preventative maintenance on VRUs, VRTs, VCUs, Wellhead Compressors, and Flares
(including 3rd party units!).
This matters too:
- Vapor Recovery System Consulting
- Emissions Testing
- Provide SERVICE LOGS!
- Field Technicians
- Competent, Dependable, and Local
WWW.OTACOMPRESSION.COM
Wide Service Coverage
WWW.OTACOMPRESSION.COMWWW.KIMARK.COM WWW.OTACOMPRESSION.COMWWW.KIMARK.COM
TABLE OF CONTENTS
WWW.OTACOMPRESSION.COMWWW.OTACOMPRESSION.COMWWW.KIMARK.COM
OVERVIEW
RECORDKEEPING / REPORTING
SURVEY PROCEDURE
APPLICABILITY
FUGITIVE EMISSIONS COMPONENT
INTRODUCTION
WWW.OTACOMPRESSION.COMWWW.KIMARK.COM
WWW.OTACOMPRESSION.COM
FUGITIVE EMISSIONS COMPONENT
WWW.OTACOMPRESSION.COMWWW.KIMARK.COM
Fugitive Emissions Component:
• Any component that has the potential to emit fugitive emissions of methane
or VOC at a well site or compressor station, including and not limited to:
• Valves, connectors, PSVs, open-ended lines, flanges, CVS’ (not subject
to 60.5411a), thief hatches, vent valves, compressors, instruments, and
meters
WHAT TO SURVEY
WWW.OTACOMPRESSION.COMWWW.KIMARK.COM
TABLE OF CONTENTS
WWW.OTACOMPRESSION.COMWWW.OTACOMPRESSION.COMWWW.KIMARK.COM
OVERVIEW
RECORDKEEPING / REPORTING
SURVEY PROCEDURE
APPLICABILITY
FUGITIVE EMISSIONS COMPONENT
INTRODUCTION
WWW.OTACOMPRESSION.COMWWW.KIMARK.COM
WWW.OTACOMPRESSION.COM
APPLICABILITY
WWW.OTACOMPRESSION.COMWWW.KIMARK.COM
Well Sites
One or more surface sites that are
constructed for the drilling and
subsequent operation of any oil well,
natural gas well, or injection well.
• Tank Batteries
• Satellite Batteries
• Surveyed Bi-Annually
Compressor Stations
Any permanent combination of one or
more compressors that move natural
gas at increased pressure through
gathering or transmission pipelines, or
into or out of storage.
• Surveyed Quarterly
Well Sites
• Standalone wellhead
• Non-affected satellite site w/or
w/out separation equipment
Compressor Stations
• One or more compressors at a
wellsite or natural gas processing
plant
WWW.OTACOMPRESSION.COMWWW.KIMARK.COM
WWW.OTACOMPRESSION.COM
APPLICABILITY
WWW.OTACOMPRESSION.COMWWW.KIMARK.COM
Construction
Commenced construction after Sept 18,
2015
Well Site
• A well (crude oil / natural gas /
produced water) is drilled and or
hydraulically fractured
Compressor Station
• A greenfield station
• Order date of compressor > 9/18/15
Modification
Well Site
• A new well is drilled , hydraulically
fractured, or hydraulically
refractured at an existing site
Compressor Station
• An additional compressor is
installed (which increases the total
HP)
• OR, one or more compressors are
replaced by one or more
compressors of > Total Horse
Power
WWW.OTACOMPRESSION.COMWWW.KIMARK.COM
WWW.OTACOMPRESSION.COM
APPLICABILITY
WWW.OTACOMPRESSION.COMWWW.KIMARK.COM
EXEMPTIONS
100,000 gal storage vessel used to recycle produced
water that has passed through two (2) stage
separation
Addition / replacement of equipment for the purpose
of process improvement accomplished without
capital expenditure
WWW.OTACOMPRESSION.COMWWW.KIMARK.COM
WWW.OTACOMPRESSION.COM
APPLICABILITY
WWW.OTACOMPRESSION.COMWWW.KIMARK.COM
EXEMPTIONS CONTINUED…
Well Site
Containing only one or more wellheads,…
One (1) or more compressors replaced
by one or more compressors of equal or
lesser Total HP
A compressor located at a well site, or an
adjacent well site AND servicing more than
one well site
WWW.OTACOMPRESSION.COMWWW.KIMARK.COM
WWW.OTACOMPRESSION.COM
APPLICABILITY
WWW.OTACOMPRESSION.COMWWW.KIMARK.COM
EXEMPTIONS CONTINUED…
CVS subject to 60.5411a
Other storage vessel openings subject to
60.5395a
Well Site
Drilled before 9/15/2015, yet completed/re-
completed after the fact and NOT hydraulically
frac’d/re-frac’d
WWW.OTACOMPRESSION.COMWWW.KIMARK.COM
Refer to 60.5365a(a)(1)(4)
WWW.OTACOMPRESSION.COM
APPLICABILITY
WWW.OTACOMPRESSION.COMWWW.KIMARK.COM
EXEMPTIONS CONTINUED…
Natural Gas-Driven Pneumatic
controllers/pumps that are designed
to vent
Natural Gas-Driven Pneumatic Piston
Pumps used to inject chemicals to
limit production problems and
protect equipment
Limited-Use Pneumatic
Pumps
Lean Glycol Circulation
Pumps
WWW.OTACOMPRESSION.COMWWW.KIMARK.COM
”…insofar as the natural
gas discharged from the
device's vent is not
considered a fugitive
emission.”
DIGITAL IMAGE
APPLICABILITYNAT GAS PNEUMATIC CONTROLLER
HSM VIDEO
WWW.OTACOMPRESSION.COMWWW.KIMARK.COM
WWW.OTACOMPRESSION.COM
APPLICABILITY
WWW.OTACOMPRESSION.COMWWW.KIMARK.COM
EXEMPTIONS CONTINUED…
Storage Vessel Vent Valves (PRVs)
WWW.OTACOMPRESSION.COMWWW.KIMARK.COM
An “Activated PSV” – refer to EPA-HQ-
OAR-2010-0505-5533
HSM VIDEO #1
APPLICABILITYVENT VALVE (PSV)
HSM VIDEO #2
WWW.OTACOMPRESSION.COMWWW.KIMARK.COM
TABLE OF CONTENTS
WWW.OTACOMPRESSION.COMWWW.OTACOMPRESSION.COMWWW.KIMARK.COM
OVERVIEW
RECORDKEEPING / REPORTING
SURVEY PROCEDURE
APPLICABILITY
FUGITIVE EMISSIONS COMPONENT
INTRODUCTION
WWW.OTACOMPRESSION.COMWWW.KIMARK.COM
WWW.OTACOMPRESSION.COM
SURVEY PROCEDURE
WWW.OTACOMPRESSION.COMWWW.KIMARK.COM
TECHNIQUE(S)
METHOD 21
500 ppm
Equipment Calibrations
Fugitives Inventory
Labor Intensive
Single Point Measurement
FID/PID
OGI
Visible Emissions
Area Scanning
Pinpoint Leaks
Remote Monitoring
Very Accurate
FLIR GF3XX
WWW.OTACOMPRESSION.COMWWW.KIMARK.COM
WWW.OTACOMPRESSION.COM
SURVEY PROCEDURE
WWW.OTACOMPRESSION.COMWWW.KIMARK.COM
Initial Survey
PROCESS
• Follow observation
path and look at all
applicable
components for
fugitives
• Confirm fugitive
leak source has
been fixed;
verification
Follow-Up
Survey Repair
• Repair or replace
any fugitive source
leaks
Survey within 60 days of
startup
Repair all leaks within 30 days
Resurvey fixed leaks within 30
days
WWW.OTACOMPRESSION.COMWWW.KIMARK.COM
TABLE OF CONTENTS
WWW.OTACOMPRESSION.COMWWW.OTACOMPRESSION.COMWWW.KIMARK.COM
OVERVIEW
RECORDKEEPING / REPORTING
SURVEY PROCEDURE
APPLICABILITY
FUGITIVE EMISSIONS COMPONENT
INTRODUCTION
WWW.OTACOMPRESSION.COMWWW.KIMARK.COM
WWW.OTACOMPRESSION.COM
RECORDKEEPING
WWW.OTACOMPRESSION.COMWWW.KIMARK.COM
WHAT IS RECORDABLE
DAILY CALIBRATION
MONITORING INSTRUMENT
DATE OF SURVEY
SURVEY DURATION
SURVEYOR CONTACT
INFO
TRAINING EXPERIENCE
WWW.OTACOMPRESSION.COMWWW.KIMARK.COM
WWW.OTACOMPRESSION.COM
RECORDKEEPING
WWW.OTACOMPRESSION.COMWWW.KIMARK.COM
CONTINUED
# OF FUGITIVES
FUGITIVES TYPE
DATE OF REPAIR
DATE OF RESURVEY
DOR SOURCES
DTM/UTM SOURCES
WWW.OTACOMPRESSION.COMWWW.KIMARK.COM
WWW.OTACOMPRESSION.COM
RECORDKEEPING
WWW.OTACOMPRESSION.COMWWW.KIMARK.COM
MONITORING PLAN
• Weather conditions, Max wind speed/direction, Max viewing distance
DAILY CALIBRATION
• OGI, Method 21, Alternative Screening Method
SURVEY TECHNIQUE(s)
• How to conduct oneself during a survey; specific-fugitive source monitoring duration; DOR; DTM/UTM
STANDARD OPERATING PROCEDURES
• Minimum of 5 years
RECORD RETENTION
• Designated path of survey; site-specific
OBSERVATION PATH
• OGI certification; 2 years of surveying experience; thermographer II training
TRAINING/EXPERIENCE
WWW.OTACOMPRESSION.COMWWW.KIMARK.COM
WWW.OTACOMPRESSION.COM
REPORTING
WWW.OTACOMPRESSION.COMWWW.KIMARK.COM
WHAT WE KNOW THUS FAR
• Initial report is due 90 days after initial compliance period or October 31, 2017
• Subsequent annual reports are due no later than same date each year
• Submit reports DIRECTLY to EPA via CEDRI
WWW.OTACOMPRESSION.COMWWW.KIMARK.COM
TABLE OF CONTENTS
WWW.OTACOMPRESSION.COMWWW.OTACOMPRESSION.COMWWW.KIMARK.COM
OVERVIEW
RECORDKEEPING / REPORTING
SURVEY PROCEDURE
APPLICABILITY
FUGITIVE EMISSIONS COMPONENT
INTRODUCTION
WWW.OTACOMPRESSION.COMWWW.KIMARK.COM
CONTACT OTA
North Texas Office
Granbury, TX
Office: (817) 326-8250
Oklahoma Office
Okemah, OK
Office: (918) 623-9922
Arkansas Office
Ozark, AR
Office: (479) 667-2310
Permian Basin Office
Midland, TX
Office: (432) 270-4157
South Texas Office
Houston, TX
Office: (210) 452-3422
WWW.OTACOMPRESSION.COMWWW.KIMARK.COM WWW.OTACOMPRESSION.COMWWW.KIMARK.COM
SERVICE COVERAGE
WWW.OTACOMPRESSION.COMWWW.KIMARK.COM WWW.OTACOMPRESSION.COMWWW.KIMARK.COM