Zentrament Super BV

Embed Size (px)

Citation preview

  • 8/2/2019 Zentrament Super BV

    1/2

    MC-Bauchemie (India) Private Limited, 201, Vardhaman Chambers, Sector-17, Vashi, Navi Mumbai 400703.Tel:022- 27893867,022- 27895231 ,022- 27892827, Fax:022- 27895265 ,022- 27893870,

    Email: [email protected], Website: www.mc-bauchemieindia.com

    Zentrament Super BVSuper plasticizer and water reducing agent.

    Product properties

    Chloride free super plasticizer

    Water reducing agent for concrete.

    Substantial increase of early & final strength

    Reduces the internal friction & thixotropy of the mix.

    Improves the workability & flowing properties of the concrete.

    Areas of application

    As a super plasticizer for ready-mix and site concrete

    Pre-cast concrete as well as site concrete

    Suitable for pre-stressed concrete

    Compatible with all MC-Concrete Retarders

    Application

    Zentrament Super BV is a chloride free super-plasticizer andwater reducing agent for concrete. It imparts high workabilityto concrete mixes so that large or difficult pours can be carriedout with little or no compaction. It can also be used to achievelarge water reductions in concrete mixes of normal workabilitythereby producing higher early and final strengths

    Advantages

    Zentrament Super BV makes concreting operations moreefficient, helps to reduce overheads and costs, improvespumping efficiency and provides optimum flow andhomogeneity.It also considerably increases the workability andflow properties of the concrete without the need for additional

    mixing water. It reduces the internal friction and thixotropy ofthe mix to a minimum without the risk of segregation therebymaking pumping operations more efficient.Zentrament Super BV can also be used as water reducingagent. It ensures greater economy in the amount of mixingwater required and so produces high early and final strengthswhile maintaining good workability. Zentrament Super BV isparticularly suitable for the pre-cast industry.

    Instructions for Use

    Add Zentrament Super BV at the job-site shortly beforeplacing. The same applies to ready-mix concrete. For bestresults mix the concrete for 1-5 mins, depending on power andvolume of the mixer. With ready-mix concrete allow 5 mins, atmaximum speed. The flow effect lasts 45-60 mins after the

    addition of Zentrament Super BV. The concrete shouldtherefore be placed without delay. MC-Concrete Retarderscan be added to give longer period of workability without lossof slump.Results of tests conducted on concrete using ZentramentSuper BV

  • 8/2/2019 Zentrament Super BV

    2/2

    MC-Bauchemie (India) Private Limited, 201, Vardhaman Chambers, Sector-17, Vashi, Navi Mumbai 400703.Tel:022- 27893867,022- 27895231 ,022- 27892827, Fax:022- 27895265 ,022- 27893870,

    Email: [email protected], Website: www.mc-bauchemieindia.com

    Technical Data for Zentrament Super BV

    Characteristic Unit Value Comments

    Density kg / cm 1.12 0.02

    Mixing ratio% by wt ofcement

    0.5% - 1.0% above 0.8% for flowconcretes

    Product Characteristics for Zentrament Super BV

    Colour Brown

    Shelf Life 12 months

    Delivery 230 kg drums and 30 kg cans.

    Storage Protect from direct sunlight and frost

    Disposal Packs must be emptied completely.

    Note: The information on this data sheet is based on our experiences and correct to the best of our knowledge. It is, however, not binding. It has to beadjusted to the individual structure, application purpose and especially to local conditions. Our data refers to the accepted engineering rules, which haveto be observed during application. This provided we are liable for the correctness of this data within the scope of our terms and conditions of sale-delivery-and-service. Recommendations of our employees which differ from the data contained in our information sheets are only binding if given inwritten form. The accepted engineering rules must be observed at all times.Edition 04 / 2007 Some technical changes have been made to this print medium. Older editions are invalid and may not be used anymore. If atechnically revised new edition is issued, this edition becomes invalid.