14
Identification of X-ray Point Sources and Study on the Nature of 62 X-ray Globular Cluster Candidates in M31 Zhou Fan, Jun Ma, Xu Zhou, Jiansheng Chen, Zhaoji Jiang, Zhenyu Wu

Zhou Fan, Jun Ma, Xu Zhou, Jiansheng Chen, Zhaoji Jiang, Zhenyu Wu

Embed Size (px)

DESCRIPTION

Identification of X-ray Point Sources and Study on the Nature of 62 X-ray Globular Cluster Candidates in M31. Zhou Fan, Jun Ma, Xu Zhou, Jiansheng Chen, Zhaoji Jiang, Zhenyu Wu. Our work contains 2 parts: 1. Identify the 8 unknown X-ray Sources. - PowerPoint PPT Presentation

Citation preview

Page 1: Zhou Fan, Jun Ma, Xu Zhou, Jiansheng Chen, Zhaoji Jiang, Zhenyu Wu

Identification of X-ray Point Sources and Study on the Nature of 62 X-ray Globular Cluster Candidates in M31

Zhou Fan, Jun Ma, Xu Zhou, Jiansheng Chen, Zhaoji Jiang, Zhenyu Wu

Page 2: Zhou Fan, Jun Ma, Xu Zhou, Jiansheng Chen, Zhaoji Jiang, Zhenyu Wu

Our work contains 2 parts:

1. Identify the 8 unknown X-ray Sources.

2.Study the optical nature of 62 GC X-ray sources.

Page 3: Zhou Fan, Jun Ma, Xu Zhou, Jiansheng Chen, Zhaoji Jiang, Zhenyu Wu

The Data of X-ray Point Sources in M31

1. Trinchieri & Fabbiano(1991) presented the positions of 108 Einstein X-ray sources

2. Primini, Forman & Jones(1993) listed the positions of 86 ROSAT HRI X-ray sources.

3. Supper et al. (2001) 2nd ROSAT detection of M31, 7 GC X-ray sources.

4. Kong et al. (2002) (Chandra ACIS)204 X-ray point sources.

5. Kaaret (2002) (Chandra HRC)143 X-ray point sources.

6. Williams et al. (2004) (Chandra HRC)166 X-ray point sources.

7. Trudolyubov & Priedhorsky (2004), (XMM-Newton & Chandra ) 43 GC X-ray sources.

Page 4: Zhou Fan, Jun Ma, Xu Zhou, Jiansheng Chen, Zhaoji Jiang, Zhenyu Wu

The BATC Optical Observation of M31

Using 60/90cm f/3 Schmidt telescope in XINGLONG Station of NAOC, CAS.

2048 X 2048(pixels) CCD. Field of view ~ 58’X 58’ , 1 pixel ~ 1.67”. Using 13 intermediate-band filters

(BATC03 - BATC15) covering from 4,000~10,000 Å.

The observation of M31 was from Nov. 15th, 1995 to Dec. 16th, 1999.

Page 5: Zhou Fan, Jun Ma, Xu Zhou, Jiansheng Chen, Zhaoji Jiang, Zhenyu Wu

Obtained 8 new X-ray sources

We compared the BATC data and the X-ray data of M31 in 3 pixels(~5”) and found 8 new X-ray sources unidentified.

Page 6: Zhou Fan, Jun Ma, Xu Zhou, Jiansheng Chen, Zhaoji Jiang, Zhenyu Wu

Identification of 8 New GC X-ray Sources

Using the 49 GC X-ray sources’ SEDs as templates, we compared them with the 8 SEDs. Combined the FWHMs, we have identified 4 new GC X-ray sources.

Criterion:χ2 <18.1(DOF=12,Q > 10%) & FWHM source > FWHM star 4 new GC X-ray sources.

Page 7: Zhou Fan, Jun Ma, Xu Zhou, Jiansheng Chen, Zhaoji Jiang, Zhenyu Wu

49 GC X-ray

sources (circles)

and 4 new GC X-ray sources (boxes)

and 9 are out the BATC

M31 Field.

Page 8: Zhou Fan, Jun Ma, Xu Zhou, Jiansheng Chen, Zhaoji Jiang, Zhenyu Wu

V distribution(58~353) (KMM fit)KMM test: the distribution is bimodal with peaks at 15.65 and 17.89,and p value ~ 0.094.

KS test: D max = 0.354 , P=4.829E-06

Page 9: Zhou Fan, Jun Ma, Xu Zhou, Jiansheng Chen, Zhaoji Jiang, Zhenyu Wu

B-V distribution(58~353)

KS test: Dmax = 0.181 , P=0.068

Page 10: Zhou Fan, Jun Ma, Xu Zhou, Jiansheng Chen, Zhaoji Jiang, Zhenyu Wu

Color (B-V) ~ V(58)

Page 11: Zhou Fan, Jun Ma, Xu Zhou, Jiansheng Chen, Zhaoji Jiang, Zhenyu Wu

The Correlation between LX (0.3-10keV) and Lopt (41)

Log (L /1035ergs-

1) = a V + ba = 0.26± 0.11; b = 6.17± 1.76, and the linear correlation coefficient r = 0.36 at the confidence level of 98.0%.

Page 12: Zhou Fan, Jun Ma, Xu Zhou, Jiansheng Chen, Zhaoji Jiang, Zhenyu Wu

Thank you !

Page 13: Zhou Fan, Jun Ma, Xu Zhou, Jiansheng Chen, Zhaoji Jiang, Zhenyu Wu
Page 14: Zhou Fan, Jun Ma, Xu Zhou, Jiansheng Chen, Zhaoji Jiang, Zhenyu Wu