2
45 O 2 3 4 5 3.Fix body to door (4 screws). Slip rail foot into track and insert end cap. 4.Push track and arm towards frame and secure in position (2 screws). 6.Insert trim plate and lower spindle cover. 5.When adjusting please note three is a MAXIMUM OF 2TURNS.Over adjustment will affect the performance of the closer.In such instance our Guarantee becomes VOID. See instructions on rear of trim plate IMPORTANT INSTALLATION NOTES: 1130B-T TRACK CLOSER Force Max. door width Max. door weight Max. opening angle Number of turns Direction NO.2 NO.3 NO.4 850mm 950mm 1100mm 40kg 60kg 80kg +3 +3~+8 +8~+14 Clockwise Clockwise Clockwise 180° NO.1 750mm 20kg 0 180° 180° 180° FACTORY PRE-SET 1.Open the door leaf to its maximum opening angle and release. The door leaf should close fully into the door frame and overcome the latch. 2.Open the door leaf and rest the latch bolt on the striker plate. Release the door leaf. The door closer should have sufficient power to latch the door leaf closed. 3.Back-check provides a cushioning effect when the door is forcibly thrown open but does not serve as substitiure for a door stop. AFTER INSTALLATION, PLEASE CHECK AND TEST: 1.Due to door closer power sizes 1&2 are NOT considered suitable for use fire/smoke door assemblies. Therefore , the minimum spring strength allowed for fire/smoke door assemblies is spring strength 3. 2.The mechanical hold open devices must NOT be installed on fire/smoke door. 3.Door closer should NOT be opened beyond the max. Opening angle of the power size you selected. 4.This door closer contains a powerful spring, which is inserted into the body under pressure. Under circumstances should not attempt to dismantle the door closer. WARNING: 1.Check the door closer every three months to ensure all fixings are secure and adjust, if necessary, adjust the closing and latching speed and make the door operating both functionally and smoothly, in accordance with the expectations of EN 1154:1997. 2.Apply light oil to arm knuckle joint and door hinges. MAINTENANCE: NO.2 Latching NO.1 Closing Back Check Closing Force SW5 + - NO.1 NO.2 Check Back 1 1.Prepare fixing holes in door and frame (use template) 2.Assemble arm to body at 45 to back face. Secure arm and rail foot with bolts provided. O 10406 ZINS-Y990-5K

ZINS-Y990-5K - Allegion · 10406 ZINS-Y990-5K. 40 min-+ 50 max 45 31 46 75 min-+ 100 120 100 230 100 230 100 80 80 120 No.1~4 No.1~4 No.1~4 No.1~4. Title: ZINS-Y990-5K Created Date:

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

  • 45O

    2 3 4 5

    3.Fix body to door (4 screws). Slip rail foot into track and insert end cap.

    4.Push track and arm towards frame and secure in position (2 screws).

    6.Insert trim plate and lower spindle cover.

    5.When adjusting please note three is a MAXIMUM OF 2TURNS.Over adjustment will affect the performance of the closer.In such instance our Guarantee becomes VOID.

    See instructions on rear of trim plate

    IMPORTANT INSTALLATION NOTES:

    1130B-T TRACK CLOSER

    Force Max. doorwidthMax. door

    weightMax. opening

    angleNumber of

    turns Direction

    NO.2

    NO.3

    NO.4

    850mm

    950mm

    1100mm

    40kg

    60kg

    80kg

    +3

    +3~+8

    +8~+14 Clockwise

    Clockwise

    Clockwise180°

    NO.1 750mm 20kg 0180°

    180°

    180°

    FACTORY PRE-SET

    1.Open the door leaf to its maximum opening angle and release. The door leaf should close fully into the door frame and overcome the latch.2.Open the door leaf and rest the latch bolt on the striker plate. Release the door leaf. The door closer should have sufficient power to latch the door leaf closed.3.Back-check provides a cushioning effect when the door is forcibly thrown open but does not serve as substitiure for a door stop.

    AFTER INSTALLATION, PLEASE CHECK AND TEST:

    1.Due to door closer power sizes 1&2 are NOT considered suitable for use fire/smoke door assemblies. Therefore , the minimum spring strength allowed for fire/smoke door assemblies is spring strength 3.2.The mechanical hold open devices must NOT be installed on fire/smoke door.3.Door closer should NOT be opened beyond the max. Opening angle of the power size you selected.4.This door closer contains a powerful spring, which is inserted into the body under pressure. Under circumstances should not attempt to dismantle the door closer.

    WARNING:

    1.Check the door closer every three months to ensure all fixings are secure and adjust, if necessary, adjust the closing and latching speed and make the door operating both functionally and smoothly, in accordance with the expectations of EN 1154:1997.2.Apply light oil to arm knuckle joint and door hinges.

    MAINTENANCE:

    NO.2 LatchingNO.1 Closing

    Back Check

    Closing Force SW5

    +-

    NO.1

    NO

    .2

    Check

    Back

    1

    1.Prepare fixing holes in door and frame (use template)2.Assemble arm to body at 45 to back face. Secure arm and rail foot with bolts provided.

    O

    10406 ZINS-Y990-5K

  • 40 m

    in

    - +

    50 max

    454631

    75 m

    in - +

    100

    120

    100

    230

    100

    230

    100

    8080

    120

    No.1~4

    No.1~4

    No.1~4

    No.1~4