Upload
lamdang
View
223
Download
0
Embed Size (px)
Citation preview
1
ED
C
2 3 4
BA
1 2 3 4
UNIV
ERSI
TY O
F SO
UTH
CARO
LINA
MECH
ANIC
AL R
ENOV
ATIO
NSSO
UTH
TOW
ER
5 6 7
E
SHEET:
SHEE
T TI
TLE:
DRAW
N BY
:
D
REV.
DRAW
ING:
DESC
RIPT
ION
03/15
/12DA
TE:
PROJ
ECT
TITL
E:
C
CHEC
KED
BY:
DATE
ORIG
. BY
DRAW
N BY
5 6
Facsimile: (803) 791-0830
B
SEAL
SEAL
Swyg
ert &
Ass
ocia
tes
C O
N S
U L
T I
N G
E
N G
I N
E E
R S
Post Office Box 11686
DBA Swygert & Assoc. Ltd.
A
Telephone: (803) 791-9300
Columbia, S.C. 29211
mail@
swygert-associates.com
7
STAT
E PR
OJEC
T NU
MBER
H27
-608
2-NA
THIS DRAWING AND THE
DESIGN THEREON ARE THE
PROPERTY OF SW
YGERT &
ASSOCIATES, LTD. THE
REPRODUC
TION
, COPYING, OR
USE OF THIS DRAWING
WITHOU
T THE WRITTEN
CON
SENT OF SW
YGERT &
ASSOCIATES IS PROHIBITED
AND ANY INFRINGEMENT WILL
BE SUBJECT TO LEGAL ACTION
.
BID
DOCU
MENT
S
UP
BASEMENTS101
ELEVEV03
CONSTRUCTION PHASING LINE.
PHASE B CONSTRUCTION AREA
AREA NOT TO BE DISTURBED BYCONSTRUCTION
PHASE A CONSTRUCTION AREA, LIMITEDSCOPE IN PHASE B, SEE ALL NOTES
DEMOLITION - TO BE NOTED ONDEMO PLANS ONLY
EXISTING TEXTURE CEILING(ASBESTOS)
INSTALL NEW VCT AND RUBBER BASE IN TYPICAL CORRIDORS HFL#01,HFL#02, AND HFL#03, FLOORS 2-18, SEE FINISH SCHEDULE.
INSTALL NEW SHAFT WALLS. SEE PARTITION TYPES AND MECHANICALFOR ADDITIONAL SCOPE AND DETAILS. SEE FINISH SCHEDULE.
INSTALL NEW DRYER VENTS. SEE MECHANICAL FOR ADDITIONALDETAILS.
NOT USED.
COORDINATE WITH MECHANICAL, ELECTRICAL, AND PLUMBING FORFULL SCOPE OF DEMOLITION/CONSTRUCTION IN ELECTRICAL ROOMS,PIPE CHASES AND MECHANICAL CHASE.
SEE DEMOLITION RELECTED CEILING PLANS AND REFLECTEDCEILINGS PLANS FOR PHASE A WORK TO OCCUR IN THIS AREA.
PAINT TYPICAL CORRIDORS HFL#01, HFL#02, AND HFL#03, FLOORS 2-18, SEE FINISH SCHEDULE AND PLANS.
1
2
3
4
5
6
7
1. SEE LEGEND. PHASE B AREA AND ADJACENT WALLS ARE NOT TO BE DISTURBEDDURING PHASE A TO PREVENT HAZARDOUS MATERIALS IN WALLS FROM BEINGDISTURBED. THE BOUNDARY WALL SEPARATING PHASE A AND PHASE B IS NOT TOBE DISTURBED DURING PHASE A.2. CONTACT OWNER UPON DISCOVERY OF ANY ASBESTOS-CONTAININGMATERIALS OR OTHER SUSPECTED HAZARDOUS MATERIALS NOT SHOWN TO BEREMOVED OR ALTERED WITHIN THE PROJECT SCOPE.3. FIELD VERIFY EXISTING CONDITIONS PRIOR TO COMMENCEMENT OFDEMOLITION AND NEW WORK. INFORMATION SHOWN IS BASED ON THE EXISTINGDRAWINGS PROVIDED BY THE OWNER. GENERAL CONTRACTOR AND SUB-CONTRACTORS ARE TO VERIFY EXISTING CONDITIONS PRIOR TO BID AND PRIORTO CONSTRUCTION.4. CONTRACTOR SHALL PHOTOGRAPH AND VIDEO ALL SPACES PRIOR TOCOMMENCEMENT OF RENOVATION/NEW WORK TO DOCUMENT PRE-CONSTRUCTION CONDITIONS. PROVIDE ARCHITECT WITH ELECTRONIC COPIESOF PHOTOGRAPHS AND VIDEO.5. CORE DRILLING IN EXISTING SLAB FOR NEW UTILITY SERVICE IS NOT SHOWN ONTHIS PLAN. SEE MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FORREQUIRED UTILITY ROUTING.6. SEE MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS FOR ADDITIONALITEMS TO REMAIN AND BE PROTECTED THROUGHOUT CONSTRUCTION,INCLUDING DATA AND POWER CONDUITS, LIGHTS, PIPES AND DUCTWORK.7. ITEMS TO BE SALVAGED AND REMOVED BY OWNER PRIOR TO DEMOLITION AREIDENTIFIED WITHIN THE SPECIFICATIONS.8. PROTECT EXISTING BUILDING SCOPE NOT INCLUDED IN DEMOLITION ORCONSTRUCTION SCOPE, INCLUDING BUT NOT LIMITED TO WALLS, FLOORING,CEILINGS, CASEWORK, AND DOORS. REPAIR OR REPLACE AREAS DAMAGEDDURING DEMOLITION OR CONSTRUCTION WITHIN THE PROJECT SCOPE, WITH NOADDITIONAL COST TO THE OWNER.9. SEE MECHANICAL, PLUMBING AND ELECTRICAL FOR SCOPE AND COORDINATIONOF NEW SYSTEMS.10. SEE PHASE B - FLOOR PLAN KEY NOTES FOR WORK TO OCCUR IN TYPICALCORRIDORS HFL#01, HFL#02, AND HFL#03, FLOORS 2-18, DURING PHASE B OFCONSTRUCTION.11. ELEVATORS ARE NOT PART OF THE PROJECT SCOPE BUT MAY BE USEDDURING THE DEMOLITION AND CONSTRUCTION PERIOD. ELEVATORS SHOULD BEPROTECTED, CLEANED AND RETURNED TO THE CONDITION IN WHICH THEY WEREFOUND AT THE END OF EACH JOB PHASE. SEE SPECIFICATIONS.12. SEE FINISH SCHEDULE AND FINISH PLANS FOR FULL SCOPE OF FINISHES.KEYNOTES REFERRING TO FINISHES ARE FOR PHASING CLARIFICATION.
1. SEE LEGEND. PHASE B AREA AND ADJACENT WALLS ARE NOT TO BE DISTURBEDDURING PHASE A TO PREVENT HAZARDOUS MATERIALS IN WALLS FROM BEINGDISTURBED. THE BOUNDARY WALL SEPARATING PHASE A AND PHASE B IS NOT TOBE DISTURBED DURING PHASE A.2. CONTACT OWNER UPON DISCOVERY OF ANY ASBESTOS-CONTAININGMATERIALS OR OTHER SUSPECTED HAZARDOUS MATERIALS NOT SHOWN TO BEREMOVED OR ALTERED WITHIN THE PROJECT SCOPE.3. FIELD VERIFY EXISTING CONDITIONS PRIOR TO COMMENCEMENT OFDEMOLITION AND NEW WORK. INFORMATION SHOWN IS BASED ON THE EXISTINGDRAWINGS PROVIDED BY THE OWNER. GENERAL CONTRACTOR AND SUB-CONTRACTORS ARE TO VERIFY EXISTING CONDITIONS PRIOR TO BID AND PRIORTO CONSTRUCTION.4. CONTRACTOR SHALL PHOTOGRAPH AND VIDEO ALL SPACES PRIOR TOCOMMENCEMENT OF RENOVATION/NEW WORK TO DOCUMENT PRE-CONSTRUCTION CONDITIONS. PROVIDE ARCHITECT WITH ELECTRONIC COPIESOF PHOTOGRAPHS AND VIDEO.5. CORE DRILLING IN EXISTING SLAB FOR NEW UTILITY SERVICE IS NOT SHOWN ONTHIS PLAN. SEE MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FORREQUIRED UTILITY ROUTING.6. SEE MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS FOR ADDITIONALITEMS TO REMAIN AND BE PROTECTED THROUGHOUT CONSTRUCTION,INCLUDING DATA AND POWER CONDUITS, LIGHTS, PIPES AND DUCTWORK.7. ITEMS TO BE SALVAGED AND REMOVED BY OWNER PRIOR TO DEMOLITION AREIDENTIFIED WITHIN THE SPECIFICATIONS.8. PROTECT EXISTING BUILDING SCOPE NOT INCLUDED IN DEMOLITION ORCONSTRUCTION SCOPE, INCLUDING BUT NOT LIMITED TO WALLS, FLOORING,CEILINGS, CASEWORK, AND DOORS. REPAIR OR REPLACE AREAS DAMAGEDDURING DEMOLITION OR CONSTRUCTION WITHIN THE PROJECT SCOPE, WITH NOADDITIONAL COST TO THE OWNER.9. SEE MECHANICAL, PLUMBING AND ELECTRICAL FOR SCOPE AND COORDINATIONOF NEW SYSTEMS.10. SEE PHASE B - FLOOR PLAN KEY NOTES FOR WORK TO OCCUR IN TYPICALCORRIDORS HFL#01, HFL#02, AND HFL#03, FLOORS 2-18, DURING PHASE B OFCONSTRUCTION.11. ELEVATORS ARE NOT PART OF THE PROJECT SCOPE BUT MAY BE USEDDURING THE DEMOLITION AND CONSTRUCTION PERIOD. ELEVATORS SHOULD BEPROTECTED, CLEANED AND RETURNED TO THE CONDITION IN WHICH THEY WEREFOUND AT THE END OF EACH JOB PHASE. SEE SPECIFICATIONS.12. SEE FINISH SCHEDULE AND FINISH PLANS FOR FULL SCOPE OF FINISHES.KEYNOTES REFERRING TO FINISHES ARE FOR PHASING CLARIFICATION.
INSTALL NEW CARPET AND RUBBER BASE. SEE FINISH SCHEDULEAND FINISH PLAN.
INSTALL INFILL WALL WHERE EXISTING FAN COIL UNIT WASREMOVED. SEE DETAILS 1-4/A3.2.
INSTALL NEW VCT AND BASE AROUND EXISTING RESIDENT ROOMFAN COIL UNITS AND VANITIES TO NEAREST FULL TILE, 2''-4" MIN.SEE FINISH SCHEDULE AND PLANS.
INSTALL NEW FLOORING. SEE FINISH SCHEDULE AND PLANS.
INSTALL NEW WALL, SEE PARTITION TYPES AND FINISH SCHEDULE.
PAINT TYPICAL CORRIDORS HFL#01, HFL#02, AND HFL#03, FLOORS2-18. SEE FINISH SCHEDULE AND FINISH PLANS.
NOT USED.
PROTECT EDGE OF CASEWORK THROUGHOUTDEMOLITION/CONSTRUCTION. INSTALL NEW FINISHED CASEWORKEDGE WHERE VANITIES HAVE BEEN REMOVED AS SHOWN IN DETAIL6/A3.1.
INSTALL PEM ALL EXTINGUISHING SYSTEM IN EXISTING CABINET,SEE MECHANICAL. PROVIDE AND INSTALL NEW LOCK ON EXISTINGOVERHEAD CABINET, SEE SPECS.
PAINT TYPICAL RESIDENCE AND COMMUNITY ROOMS. SEE FINISHSCHEDULE AND FINISH PLANS.
A
B
C
D
E
F
G
H
J
K
N
PHASE B WORK - NOTE TO CONTRACTORS:
1. DURING THE PROCESS OF INSTALLING HANGERS, SOFFITS, FAN COILS, METAL PAN COVERS, NEW PARTITIONS OR ANY OTHERMATERIAL OR EQUIPMENT AT THE CEILINGS OF THE EXISTING RESIDENT ROOMS ON FLOORS 2 THRU 18, THE CONTRACTORSHALL NOT COME IN CONTACT WITH THE SPRAY APPLIED TEXTURED CEILING MATERIAL THAT IS TO REMAIN IN PLACE AFTER THEPARTIAL ABATEMENT OF ASBESTOS FROM THE CEILINGS. CONTAMINATION OF THESE SPACES CAUSED BY DAMAGE TO THECEILING MATERIAL SHALL BE CLEANED UP AT THE CONTRACTOR'S EXPENSE, INCLUDING BUT NOT LIMITED TO, COSTSASSOCIATED WITH CLEARING THESE SPACES FOR RE-ACCESS, I.E. AIR SAMPLING.
2. DURING THE PROCESS OF INSTALLING UL RATED RACEWAYS AT CORRIDOR WALL PENETRATION, INSTALLATION OF NEWPARTITIONS, THE CONTRACTOR SHALL NOT DISTURB THE EXISTING GYPSUM BOARD IN ANY FASHION. NO PENETRATIONS WILLBE ALLOWED ONCE THE ASBESTOS ABATEMENT HAS BEEN COMPLETED BY THE ABATEMENT CONTRACTOR.
PHASE A WORK - NOTE TO CONTRACTORS:
1. NO PENETRATIONS OR ATTACHMENTS TO THE EXISTING GYPSUM BOARD PARTITIONS WILL BE ALLOWED ONCE THEASBESTOS ABATEMENT HAS BEEN COMPLETED BY THE ABATEMENT CONTRACTOR.
2. THE CONTRACTOR SHALL NOT COME IN CONTACT WITH THE GYPSUM BOARD MATERIAL THAT IS TO REMAIN IN PLACE AFTERTHE PARTIAL ABATEMENT OF ASBESTOS FROM THE CORRIDOR PARTITIONS ON THE EXISTING FLOORS 2 THRU 18 AND OTHERPARTITIONS ON THE BASEMENT AND GROUND LEVELS. CONTAMINATION OF THESE SPACES CAUSED BY DAMAGE TO THEGYPSUM BOARD MATERIAL SHALL BE CLEANED UP AT THE CONTRACTOR'S EXPENSE, INCLUDING BUT NOT LIMITED TO, COSTSASSOCIATED WITH CLEARING THESE SPACES FOR RE-ACCESS, I.E. AIR SAMPLING.
REFERENCED ON: 1/4" = 1'-0"A1.001 BASEMENT FLOOR PLAN
LEGEND
PHASE A - FLOOR PLAN KEYNOTESPHASE A - GENERAL FLOOR PLAN NOTES
PHASE B - GENERAL FLOOR PLAN NOTES PHASE B - FLOOR PLAN KEYNOTES
A1.00
BASE
MENT
FLO
ORPL
AN
RMB
SAL
1
ED
C
2 3 4
BA
1 2 3 4
UNIV
ERSI
TY O
F SO
UTH
CARO
LINA
MECH
ANIC
AL R
ENOV
ATIO
NSSO
UTH
TOW
ER
5 6 7
E
SHEET:
SHEE
T TI
TLE:
DRAW
N BY
:
D
REV.
DRAW
ING:
DESC
RIPT
ION
03/15
/12DA
TE:
PROJ
ECT
TITL
E:
C
CHEC
KED
BY:
DATE
ORIG
. BY
DRAW
N BY
5 6
Facsimile: (803) 791-0830
B
SEAL
SEAL
Swyg
ert &
Ass
ocia
tes
C O
N S
U L
T I
N G
E
N G
I N
E E
R S
Post Office Box 11686
DBA Swygert & Assoc. Ltd.
A
Telephone: (803) 791-9300
Columbia, S.C. 29211
mail@
swygert-associates.com
7
STAT
E PR
OJEC
T NU
MBER
H27
-608
2-NA
THIS DRAWING AND THE
DESIGN THEREON ARE THE
PROPERTY OF SW
YGERT &
ASSOCIATES, LTD. THE
REPRODUC
TION
, COPYING, OR
USE OF THIS DRAWING
WITHOU
T THE WRITTEN
CON
SENT OF SW
YGERT &
ASSOCIATES IS PROHIBITED
AND ANY INFRINGEMENT WILL
BE SUBJECT TO LEGAL ACTION
.
BID
DOCU
MENT
S
D W
UP
REF.
DN
UP
TRASH002A
TRASH002
VENDING001
OFFICE012A
CUST.012
STORAGE011
CUST.009
LAUNDRY007
TLT008
TLT006
LAUNDRY007A
BEDROOM005
LIVING003
CHASE004
HALLH004
HALLH003
HALLH002
HALLH005
HALLH001
ELEC010
STAIRST01
OPENTOBELOW
PANTRY003B
MECH003A
ELEVEV01
ELEVEV02
2
3
S2C
EVEV03
5
5
5
J
CONSTRUCTION PHASING LINE.
PHASE B CONSTRUCTION AREA
AREA NOT TO BE DISTURBED BYCONSTRUCTION
PHASE A CONSTRUCTION AREA, LIMITEDSCOPE IN PHASE B, SEE ALL NOTES
DEMOLITION - TO BE NOTED ONDEMO PLANS ONLY
EXISTING TEXTURE CEILING(ASBESTOS)
INSTALL NEW VCT AND RUBBER BASE IN TYPICAL CORRIDORS HFL#01,HFL#02, AND HFL#03, FLOORS 2-18, SEE FINISH SCHEDULE.
INSTALL NEW SHAFT WALLS. SEE PARTITION TYPES AND MECHANICALFOR ADDITIONAL SCOPE AND DETAILS. SEE FINISH SCHEDULE.
INSTALL NEW DRYER VENTS. SEE MECHANICAL FOR ADDITIONALDETAILS.
NOT USED.
COORDINATE WITH MECHANICAL, ELECTRICAL, AND PLUMBING FORFULL SCOPE OF DEMOLITION/CONSTRUCTION IN ELECTRICAL ROOMS,PIPE CHASES AND MECHANICAL CHASE.
SEE DEMOLITION RELECTED CEILING PLANS AND REFLECTEDCEILINGS PLANS FOR PHASE A WORK TO OCCUR IN THIS AREA.
PAINT TYPICAL CORRIDORS HFL#01, HFL#02, AND HFL#03, FLOORS 2-18, SEE FINISH SCHEDULE AND PLANS.
1
2
3
4
5
6
7
1. SEE LEGEND. PHASE B AREA AND ADJACENT WALLS ARE NOT TO BE DISTURBEDDURING PHASE A TO PREVENT HAZARDOUS MATERIALS IN WALLS FROM BEINGDISTURBED. THE BOUNDARY WALL SEPARATING PHASE A AND PHASE B IS NOT TOBE DISTURBED DURING PHASE A.2. CONTACT OWNER UPON DISCOVERY OF ANY ASBESTOS-CONTAININGMATERIALS OR OTHER SUSPECTED HAZARDOUS MATERIALS NOT SHOWN TO BEREMOVED OR ALTERED WITHIN THE PROJECT SCOPE.3. FIELD VERIFY EXISTING CONDITIONS PRIOR TO COMMENCEMENT OFDEMOLITION AND NEW WORK. INFORMATION SHOWN IS BASED ON THE EXISTINGDRAWINGS PROVIDED BY THE OWNER. GENERAL CONTRACTOR AND SUB-CONTRACTORS ARE TO VERIFY EXISTING CONDITIONS PRIOR TO BID AND PRIORTO CONSTRUCTION.4. CONTRACTOR SHALL PHOTOGRAPH AND VIDEO ALL SPACES PRIOR TOCOMMENCEMENT OF RENOVATION/NEW WORK TO DOCUMENT PRE-CONSTRUCTION CONDITIONS. PROVIDE ARCHITECT WITH ELECTRONIC COPIESOF PHOTOGRAPHS AND VIDEO.5. CORE DRILLING IN EXISTING SLAB FOR NEW UTILITY SERVICE IS NOT SHOWN ONTHIS PLAN. SEE MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FORREQUIRED UTILITY ROUTING.6. SEE MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS FOR ADDITIONALITEMS TO REMAIN AND BE PROTECTED THROUGHOUT CONSTRUCTION,INCLUDING DATA AND POWER CONDUITS, LIGHTS, PIPES AND DUCTWORK.7. ITEMS TO BE SALVAGED AND REMOVED BY OWNER PRIOR TO DEMOLITION AREIDENTIFIED WITHIN THE SPECIFICATIONS.8. PROTECT EXISTING BUILDING SCOPE NOT INCLUDED IN DEMOLITION ORCONSTRUCTION SCOPE, INCLUDING BUT NOT LIMITED TO WALLS, FLOORING,CEILINGS, CASEWORK, AND DOORS. REPAIR OR REPLACE AREAS DAMAGEDDURING DEMOLITION OR CONSTRUCTION WITHIN THE PROJECT SCOPE, WITH NOADDITIONAL COST TO THE OWNER.9. SEE MECHANICAL, PLUMBING AND ELECTRICAL FOR SCOPE AND COORDINATIONOF NEW SYSTEMS.10. SEE PHASE B - FLOOR PLAN KEY NOTES FOR WORK TO OCCUR IN TYPICALCORRIDORS HFL#01, HFL#02, AND HFL#03, FLOORS 2-18, DURING PHASE B OFCONSTRUCTION.11. ELEVATORS ARE NOT PART OF THE PROJECT SCOPE BUT MAY BE USEDDURING THE DEMOLITION AND CONSTRUCTION PERIOD. ELEVATORS SHOULD BEPROTECTED, CLEANED AND RETURNED TO THE CONDITION IN WHICH THEY WEREFOUND AT THE END OF EACH JOB PHASE. SEE SPECIFICATIONS.12. SEE FINISH SCHEDULE AND FINISH PLANS FOR FULL SCOPE OF FINISHES.KEYNOTES REFERRING TO FINISHES ARE FOR PHASING CLARIFICATION.
INSTALL NEW CARPET AND RUBBER BASE. SEE FINISH SCHEDULEAND FINISH PLAN.
INSTALL INFILL WALL WHERE EXISTING FAN COIL UNIT WASREMOVED. SEE DETAILS 1-4/A3.2.
INSTALL NEW VCT AND BASE AROUND EXISTING RESIDENT ROOMFAN COIL UNITS AND VANITIES TO NEAREST FULL TILE, 2''-4" MIN.SEE FINISH SCHEDULE AND PLANS.
INSTALL NEW FLOORING. SEE FINISH SCHEDULE AND PLANS.
INSTALL NEW WALL, SEE PARTITION TYPES AND FINISH SCHEDULE.
PAINT TYPICAL CORRIDORS HFL#01, HFL#02, AND HFL#03, FLOORS2-18. SEE FINISH SCHEDULE AND FINISH PLANS.
NOT USED.
PROTECT EDGE OF CASEWORK THROUGHOUTDEMOLITION/CONSTRUCTION. INSTALL NEW FINISHED CASEWORKEDGE WHERE VANITIES HAVE BEEN REMOVED AS SHOWN IN DETAIL6/A3.1.
INSTALL PEM ALL EXTINGUISHING SYSTEM IN EXISTING CABINET,SEE MECHANICAL. PROVIDE AND INSTALL NEW LOCK ON EXISTINGOVERHEAD CABINET, SEE SPECS.
PAINT TYPICAL RESIDENCE AND COMMUNITY ROOMS. SEE FINISHSCHEDULE AND FINISH PLANS.
A
B
C
D
E
F
G
H
J
K
1. SEE LEGEND. PHASE B AREA AND ADJACENT WALLS ARE NOT TO BE DISTURBEDDURING PHASE A TO PREVENT HAZARDOUS MATERIALS IN WALLS FROM BEINGDISTURBED. THE BOUNDARY WALL SEPARATING PHASE A AND PHASE B IS NOT TOBE DISTURBED DURING PHASE A.2. CONTACT OWNER UPON DISCOVERY OF ANY ASBESTOS-CONTAININGMATERIALS OR OTHER SUSPECTED HAZARDOUS MATERIALS NOT SHOWN TO BEREMOVED OR ALTERED WITHIN THE PROJECT SCOPE.3. FIELD VERIFY EXISTING CONDITIONS PRIOR TO COMMENCEMENT OFDEMOLITION AND NEW WORK. INFORMATION SHOWN IS BASED ON THE EXISTINGDRAWINGS PROVIDED BY THE OWNER. GENERAL CONTRACTOR AND SUB-CONTRACTORS ARE TO VERIFY EXISTING CONDITIONS PRIOR TO BID AND PRIORTO CONSTRUCTION.4. CONTRACTOR SHALL PHOTOGRAPH AND VIDEO ALL SPACES PRIOR TOCOMMENCEMENT OF RENOVATION/NEW WORK TO DOCUMENT PRE-CONSTRUCTION CONDITIONS. PROVIDE ARCHITECT WITH ELECTRONIC COPIESOF PHOTOGRAPHS AND VIDEO.5. CORE DRILLING IN EXISTING SLAB FOR NEW UTILITY SERVICE IS NOT SHOWN ONTHIS PLAN. SEE MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FORREQUIRED UTILITY ROUTING.6. SEE MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS FOR ADDITIONALITEMS TO REMAIN AND BE PROTECTED THROUGHOUT CONSTRUCTION,INCLUDING DATA AND POWER CONDUITS, LIGHTS, PIPES AND DUCTWORK.7. ITEMS TO BE SALVAGED AND REMOVED BY OWNER PRIOR TO DEMOLITION AREIDENTIFIED WITHIN THE SPECIFICATIONS.8. PROTECT EXISTING BUILDING SCOPE NOT INCLUDED IN DEMOLITION ORCONSTRUCTION SCOPE, INCLUDING BUT NOT LIMITED TO WALLS, FLOORING,CEILINGS, CASEWORK, AND DOORS. REPAIR OR REPLACE AREAS DAMAGEDDURING DEMOLITION OR CONSTRUCTION WITHIN THE PROJECT SCOPE, WITH NOADDITIONAL COST TO THE OWNER.9. SEE MECHANICAL, PLUMBING AND ELECTRICAL FOR SCOPE AND COORDINATIONOF NEW SYSTEMS.10. SEE PHASE B - FLOOR PLAN KEY NOTES FOR WORK TO OCCUR IN TYPICALCORRIDORS HFL#01, HFL#02, AND HFL#03, FLOORS 2-18, DURING PHASE B OFCONSTRUCTION.11. ELEVATORS ARE NOT PART OF THE PROJECT SCOPE BUT MAY BE USEDDURING THE DEMOLITION AND CONSTRUCTION PERIOD. ELEVATORS SHOULD BEPROTECTED, CLEANED AND RETURNED TO THE CONDITION IN WHICH THEY WEREFOUND AT THE END OF EACH JOB PHASE. SEE SPECIFICATIONS.12. SEE FINISH SCHEDULE AND FINISH PLANS FOR FULL SCOPE OF FINISHES.KEYNOTES REFERRING TO FINISHES ARE FOR PHASING CLARIFICATION.
N
PHASE A WORK - NOTE TO CONTRACTORS:
1. NO PENETRATIONS OR ATTACHMENTS TO THE EXISTING GYPSUM BOARD PARTITIONS WILL BE ALLOWED ONCE THEASBESTOS ABATEMENT HAS BEEN COMPLETED BY THE ABATEMENT CONTRACTOR.
2. THE CONTRACTOR SHALL NOT COME IN CONTACT WITH THE GYPSUM BOARD MATERIAL THAT IS TO REMAIN IN PLACE AFTERTHE PARTIAL ABATEMENT OF ASBESTOS FROM THE CORRIDOR PARTITIONS ON THE EXISTING FLOORS 2 THRU 18 AND OTHERPARTITIONS ON THE BASEMENT AND GROUND LEVELS. CONTAMINATION OF THESE SPACES CAUSED BY DAMAGE TO THEGYPSUM BOARD MATERIAL SHALL BE CLEANED UP AT THE CONTRACTOR'S EXPENSE, INCLUDING BUT NOT LIMITED TO, COSTSASSOCIATED WITH CLEARING THESE SPACES FOR RE-ACCESS, I.E. AIR SAMPLING.
PHASE B WORK - NOTE TO CONTRACTORS:
1. DURING THE PROCESS OF INSTALLING HANGERS, SOFFITS, FAN COILS, METAL PAN COVERS, NEW PARTITIONS OR ANY OTHERMATERIAL OR EQUIPMENT AT THE CEILINGS OF THE EXISTING RESIDENT ROOMS ON FLOORS 2 THRU 18, THE CONTRACTORSHALL NOT COME IN CONTACT WITH THE SPRAY APPLIED TEXTURED CEILING MATERIAL THAT IS TO REMAIN IN PLACE AFTER THEPARTIAL ABATEMENT OF ASBESTOS FROM THE CEILINGS. CONTAMINATION OF THESE SPACES CAUSED BY DAMAGE TO THECEILING MATERIAL SHALL BE CLEANED UP AT THE CONTRACTOR'S EXPENSE, INCLUDING BUT NOT LIMITED TO, COSTSASSOCIATED WITH CLEARING THESE SPACES FOR RE-ACCESS, I.E. AIR SAMPLING.
2. DURING THE PROCESS OF INSTALLING UL RATED RACEWAYS AT CORRIDOR WALL PENETRATION, INSTALLATION OF NEWPARTITIONS, THE CONTRACTOR SHALL NOT DISTURB THE EXISTING GYPSUM BOARD IN ANY FASHION. NO PENETRATIONS WILLBE ALLOWED ONCE THE ASBESTOS ABATEMENT HAS BEEN COMPLETED BY THE ABATEMENT CONTRACTOR.
REFERENCED ON: 1/4" = 1'-0"A1.011 GROUND LEVEL FLOOR PLAN
LEGEND
PHASE A - FLOOR PLAN KEYNOTES
PHASE B - GENERAL FLOOR PLAN NOTES PHASE B - FLOOR PLAN KEYNOTES
PHASE A - GENERAL FLOOR PLAN NOTES
A1.01
GROU
ND LE
VEL F
LOOR
PLAN
RMB
SAL
1
ED
C
2 3 4
BA
1 2 3 4
UNIV
ERSI
TY O
F SO
UTH
CARO
LINA
MECH
ANIC
AL R
ENOV
ATIO
NSSO
UTH
TOW
ER
5 6 7
E
SHEET:
SHEE
T TI
TLE:
DRAW
N BY
:
D
REV.
DRAW
ING:
DESC
RIPT
ION
03/15
/12DA
TE:
PROJ
ECT
TITL
E:
C
CHEC
KED
BY:
DATE
ORIG
. BY
DRAW
N BY
5 6
Facsimile: (803) 791-0830
B
SEAL
SEAL
Swyg
ert &
Ass
ocia
tes
C O
N S
U L
T I
N G
E
N G
I N
E E
R S
Post Office Box 11686
DBA Swygert & Assoc. Ltd.
A
Telephone: (803) 791-9300
Columbia, S.C. 29211
mail@
swygert-associates.com
7
STAT
E PR
OJEC
T NU
MBER
H27
-608
2-NA
THIS DRAWING AND THE
DESIGN THEREON ARE THE
PROPERTY OF SW
YGERT &
ASSOCIATES, LTD. THE
REPRODUC
TION
, COPYING, OR
USE OF THIS DRAWING
WITHOU
T THE WRITTEN
CON
SENT OF SW
YGERT &
ASSOCIATES IS PROHIBITED
AND ANY INFRINGEMENT WILL
BE SUBJECT TO LEGAL ACTION
.
BID
DOCU
MENT
S
DN
UP
UP
DN
REF
.
VESTIBULEV101
VESTIBULEV102
HALLH101
RA KITCHEN103D
RA LIVING103
RA BEDROOM103A
OFFICE102
CLST103C
TLT103B
MEN105CUST
104
CHASE104A
ELEC106
STUDY107
COVEREDENTRY
2
5
5
5
5
S2C
J
LOBBY101
LOBBY A101A
CONSTRUCTION PHASING LINE.
PHASE B CONSTRUCTION AREA
AREA NOT TO BE DISTURBED BYCONSTRUCTION
PHASE A CONSTRUCTION AREA, LIMITEDSCOPE IN PHASE B, SEE ALL NOTES
DEMOLITION - TO BE NOTED ONDEMO PLANS ONLY
EXISTING TEXTURE CEILING(ASBESTOS)
INSTALL NEW VCT AND RUBBER BASE IN TYPICAL CORRIDORS HFL#01,HFL#02, AND HFL#03, FLOORS 2-18, SEE FINISH SCHEDULE.
INSTALL NEW SHAFT WALLS. SEE PARTITION TYPES AND MECHANICALFOR ADDITIONAL SCOPE AND DETAILS. SEE FINISH SCHEDULE.
INSTALL NEW DRYER VENTS. SEE MECHANICAL FOR ADDITIONALDETAILS.
NOT USED.
COORDINATE WITH MECHANICAL, ELECTRICAL, AND PLUMBING FORFULL SCOPE OF DEMOLITION/CONSTRUCTION IN ELECTRICAL ROOMS,PIPE CHASES AND MECHANICAL CHASE.
SEE DEMOLITION RELECTED CEILING PLANS AND REFLECTEDCEILINGS PLANS FOR PHASE A WORK TO OCCUR IN THIS AREA.
PAINT TYPICAL CORRIDORS HFL#01, HFL#02, AND HFL#03, FLOORS 2-18, SEE FINISH SCHEDULE AND PLANS.
1
2
3
4
5
6
7
1. SEE LEGEND. PHASE B AREA AND ADJACENT WALLS ARE NOT TO BE DISTURBEDDURING PHASE A TO PREVENT HAZARDOUS MATERIALS IN WALLS FROM BEINGDISTURBED. THE BOUNDARY WALL SEPARATING PHASE A AND PHASE B IS NOT TOBE DISTURBED DURING PHASE A.2. CONTACT OWNER UPON DISCOVERY OF ANY ASBESTOS-CONTAININGMATERIALS OR OTHER SUSPECTED HAZARDOUS MATERIALS NOT SHOWN TO BEREMOVED OR ALTERED WITHIN THE PROJECT SCOPE.3. FIELD VERIFY EXISTING CONDITIONS PRIOR TO COMMENCEMENT OFDEMOLITION AND NEW WORK. INFORMATION SHOWN IS BASED ON THE EXISTINGDRAWINGS PROVIDED BY THE OWNER. GENERAL CONTRACTOR AND SUB-CONTRACTORS ARE TO VERIFY EXISTING CONDITIONS PRIOR TO BID AND PRIORTO CONSTRUCTION.4. CONTRACTOR SHALL PHOTOGRAPH AND VIDEO ALL SPACES PRIOR TOCOMMENCEMENT OF RENOVATION/NEW WORK TO DOCUMENT PRE-CONSTRUCTION CONDITIONS. PROVIDE ARCHITECT WITH ELECTRONIC COPIESOF PHOTOGRAPHS AND VIDEO.5. CORE DRILLING IN EXISTING SLAB FOR NEW UTILITY SERVICE IS NOT SHOWN ONTHIS PLAN. SEE MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FORREQUIRED UTILITY ROUTING.6. SEE MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS FOR ADDITIONALITEMS TO REMAIN AND BE PROTECTED THROUGHOUT CONSTRUCTION,INCLUDING DATA AND POWER CONDUITS, LIGHTS, PIPES AND DUCTWORK.7. ITEMS TO BE SALVAGED AND REMOVED BY OWNER PRIOR TO DEMOLITION AREIDENTIFIED WITHIN THE SPECIFICATIONS.8. PROTECT EXISTING BUILDING SCOPE NOT INCLUDED IN DEMOLITION ORCONSTRUCTION SCOPE, INCLUDING BUT NOT LIMITED TO WALLS, FLOORING,CEILINGS, CASEWORK, AND DOORS. REPAIR OR REPLACE AREAS DAMAGEDDURING DEMOLITION OR CONSTRUCTION WITHIN THE PROJECT SCOPE, WITH NOADDITIONAL COST TO THE OWNER.9. SEE MECHANICAL, PLUMBING AND ELECTRICAL FOR SCOPE AND COORDINATIONOF NEW SYSTEMS.10. SEE PHASE B - FLOOR PLAN KEY NOTES FOR WORK TO OCCUR IN TYPICALCORRIDORS HFL#01, HFL#02, AND HFL#03, FLOORS 2-18, DURING PHASE B OFCONSTRUCTION.11. ELEVATORS ARE NOT PART OF THE PROJECT SCOPE BUT MAY BE USEDDURING THE DEMOLITION AND CONSTRUCTION PERIOD. ELEVATORS SHOULD BEPROTECTED, CLEANED AND RETURNED TO THE CONDITION IN WHICH THEY WEREFOUND AT THE END OF EACH JOB PHASE. SEE SPECIFICATIONS.12. SEE FINISH SCHEDULE AND FINISH PLANS FOR FULL SCOPE OF FINISHES.KEYNOTES REFERRING TO FINISHES ARE FOR PHASING CLARIFICATION.
1. SEE LEGEND. PHASE B AREA AND ADJACENT WALLS ARE NOT TO BE DISTURBEDDURING PHASE A TO PREVENT HAZARDOUS MATERIALS IN WALLS FROM BEINGDISTURBED. THE BOUNDARY WALL SEPARATING PHASE A AND PHASE B IS NOT TOBE DISTURBED DURING PHASE A.2. CONTACT OWNER UPON DISCOVERY OF ANY ASBESTOS-CONTAININGMATERIALS OR OTHER SUSPECTED HAZARDOUS MATERIALS NOT SHOWN TO BEREMOVED OR ALTERED WITHIN THE PROJECT SCOPE.3. FIELD VERIFY EXISTING CONDITIONS PRIOR TO COMMENCEMENT OFDEMOLITION AND NEW WORK. INFORMATION SHOWN IS BASED ON THE EXISTINGDRAWINGS PROVIDED BY THE OWNER. GENERAL CONTRACTOR AND SUB-CONTRACTORS ARE TO VERIFY EXISTING CONDITIONS PRIOR TO BID AND PRIORTO CONSTRUCTION.4. CONTRACTOR SHALL PHOTOGRAPH AND VIDEO ALL SPACES PRIOR TOCOMMENCEMENT OF RENOVATION/NEW WORK TO DOCUMENT PRE-CONSTRUCTION CONDITIONS. PROVIDE ARCHITECT WITH ELECTRONIC COPIESOF PHOTOGRAPHS AND VIDEO.5. CORE DRILLING IN EXISTING SLAB FOR NEW UTILITY SERVICE IS NOT SHOWN ONTHIS PLAN. SEE MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FORREQUIRED UTILITY ROUTING.6. SEE MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS FOR ADDITIONALITEMS TO REMAIN AND BE PROTECTED THROUGHOUT CONSTRUCTION,INCLUDING DATA AND POWER CONDUITS, LIGHTS, PIPES AND DUCTWORK.7. ITEMS TO BE SALVAGED AND REMOVED BY OWNER PRIOR TO DEMOLITION AREIDENTIFIED WITHIN THE SPECIFICATIONS.8. PROTECT EXISTING BUILDING SCOPE NOT INCLUDED IN DEMOLITION ORCONSTRUCTION SCOPE, INCLUDING BUT NOT LIMITED TO WALLS, FLOORING,CEILINGS, CASEWORK, AND DOORS. REPAIR OR REPLACE AREAS DAMAGEDDURING DEMOLITION OR CONSTRUCTION WITHIN THE PROJECT SCOPE, WITH NOADDITIONAL COST TO THE OWNER.9. SEE MECHANICAL, PLUMBING AND ELECTRICAL FOR SCOPE AND COORDINATIONOF NEW SYSTEMS.10. SEE PHASE B - FLOOR PLAN KEY NOTES FOR WORK TO OCCUR IN TYPICALCORRIDORS HFL#01, HFL#02, AND HFL#03, FLOORS 2-18, DURING PHASE B OFCONSTRUCTION.11. ELEVATORS ARE NOT PART OF THE PROJECT SCOPE BUT MAY BE USEDDURING THE DEMOLITION AND CONSTRUCTION PERIOD. ELEVATORS SHOULD BEPROTECTED, CLEANED AND RETURNED TO THE CONDITION IN WHICH THEY WEREFOUND AT THE END OF EACH JOB PHASE. SEE SPECIFICATIONS.12. SEE FINISH SCHEDULE AND FINISH PLANS FOR FULL SCOPE OF FINISHES.KEYNOTES REFERRING TO FINISHES ARE FOR PHASING CLARIFICATION.
INSTALL NEW CARPET AND RUBBER BASE. SEE FINISH SCHEDULEAND FINISH PLAN.
INSTALL INFILL WALL WHERE EXISTING FAN COIL UNIT WASREMOVED. SEE DETAILS 1-4/A3.2.
INSTALL NEW VCT AND BASE AROUND EXISTING RESIDENT ROOMFAN COIL UNITS AND VANITIES TO NEAREST FULL TILE, 2''-4" MIN.SEE FINISH SCHEDULE AND PLANS.
INSTALL NEW FLOORING. SEE FINISH SCHEDULE AND PLANS.
INSTALL NEW WALL, SEE PARTITION TYPES AND FINISH SCHEDULE.
PAINT TYPICAL CORRIDORS HFL#01, HFL#02, AND HFL#03, FLOORS2-18. SEE FINISH SCHEDULE AND FINISH PLANS.
NOT USED.
PROTECT EDGE OF CASEWORK THROUGHOUTDEMOLITION/CONSTRUCTION. INSTALL NEW FINISHED CASEWORKEDGE WHERE VANITIES HAVE BEEN REMOVED AS SHOWN IN DETAIL6/A3.1.
INSTALL PEM ALL EXTINGUISHING SYSTEM IN EXISTING CABINET,SEE MECHANICAL. PROVIDE AND INSTALL NEW LOCK ON EXISTINGOVERHEAD CABINET, SEE SPECS.
PAINT TYPICAL RESIDENCE AND COMMUNITY ROOMS. SEE FINISHSCHEDULE AND FINISH PLANS.
A
B
C
D
E
F
G
H
J
K
N
PHASE B WORK - NOTE TO CONTRACTORS:
1. DURING THE PROCESS OF INSTALLING HANGERS, SOFFITS, FAN COILS, METAL PAN COVERS, NEW PARTITIONS OR ANY OTHERMATERIAL OR EQUIPMENT AT THE CEILINGS OF THE EXISTING RESIDENT ROOMS ON FLOORS 2 THRU 18, THE CONTRACTORSHALL NOT COME IN CONTACT WITH THE SPRAY APPLIED TEXTURED CEILING MATERIAL THAT IS TO REMAIN IN PLACE AFTER THEPARTIAL ABATEMENT OF ASBESTOS FROM THE CEILINGS. CONTAMINATION OF THESE SPACES CAUSED BY DAMAGE TO THECEILING MATERIAL SHALL BE CLEANED UP AT THE CONTRACTOR'S EXPENSE, INCLUDING BUT NOT LIMITED TO, COSTSASSOCIATED WITH CLEARING THESE SPACES FOR RE-ACCESS, I.E. AIR SAMPLING.
2. DURING THE PROCESS OF INSTALLING UL RATED RACEWAYS AT CORRIDOR WALL PENETRATION, INSTALLATION OF NEWPARTITIONS, THE CONTRACTOR SHALL NOT DISTURB THE EXISTING GYPSUM BOARD IN ANY FASHION. NO PENETRATIONS WILLBE ALLOWED ONCE THE ASBESTOS ABATEMENT HAS BEEN COMPLETED BY THE ABATEMENT CONTRACTOR.
PHASE A WORK - NOTE TO CONTRACTORS:
1. NO PENETRATIONS OR ATTACHMENTS TO THE EXISTING GYPSUM BOARD PARTITIONS WILL BE ALLOWED ONCE THEASBESTOS ABATEMENT HAS BEEN COMPLETED BY THE ABATEMENT CONTRACTOR.
2. THE CONTRACTOR SHALL NOT COME IN CONTACT WITH THE GYPSUM BOARD MATERIAL THAT IS TO REMAIN IN PLACE AFTERTHE PARTIAL ABATEMENT OF ASBESTOS FROM THE CORRIDOR PARTITIONS ON THE EXISTING FLOORS 2 THRU 18 AND OTHERPARTITIONS ON THE BASEMENT AND GROUND LEVELS. CONTAMINATION OF THESE SPACES CAUSED BY DAMAGE TO THEGYPSUM BOARD MATERIAL SHALL BE CLEANED UP AT THE CONTRACTOR'S EXPENSE, INCLUDING BUT NOT LIMITED TO, COSTSASSOCIATED WITH CLEARING THESE SPACES FOR RE-ACCESS, I.E. AIR SAMPLING.
REFERENCED ON: 1/4" = 1'-0"A1.11 FIRST FLOOR PLAN
LEGEND
PHASE A - FLOOR PLAN KEYNOTESPHASE A - GENERAL FLOOR PLAN NOTES
PHASE B - GENERAL FLOOR PLAN NOTES PHASE B - FLOOR PLAN KEYNOTES
A1.1
FIRS
T FL
OOR
PLAN
RMB
SAL
1
ED
C
2 3 4
BA
1 2 3 4
UNIV
ERSI
TY O
F SO
UTH
CARO
LINA
MECH
ANIC
AL R
ENOV
ATIO
NSSO
UTH
TOW
ER
5 6 7
E
SHEET:
SHEE
T TI
TLE:
DRAW
N BY
:
D
REV.
DRAW
ING:
DESC
RIPT
ION
03/15
/12DA
TE:
PROJ
ECT
TITL
E:
C
CHEC
KED
BY:
DATE
ORIG
. BY
DRAW
N BY
5 6
Facsimile: (803) 791-0830
B
SEAL
SEAL
Swyg
ert &
Ass
ocia
tes
C O
N S
U L
T I
N G
E
N G
I N
E E
R S
Post Office Box 11686
DBA Swygert & Assoc. Ltd.
A
Telephone: (803) 791-9300
Columbia, S.C. 29211
mail@
swygert-associates.com
7
STAT
E PR
OJEC
T NU
MBER
H27
-608
2-NA
THIS DRAWING AND THE
DESIGN THEREON ARE THE
PROPERTY OF SW
YGERT &
ASSOCIATES, LTD. THE
REPRODUC
TION
, COPYING, OR
USE OF THIS DRAWING
WITHOU
T THE WRITTEN
CON
SENT OF SW
YGERT &
ASSOCIATES IS PROHIBITED
AND ANY INFRINGEMENT WILL
BE SUBJECT TO LEGAL ACTION
.
BID
DOCU
MENT
S
UP
UPDN
DN
2
A3.2
7 A
7 A
1 A
5
5
B
C
B
C
B
C
B
C
B
C
B
D
B
C
B
C
B
C
B
C
B
C
B
C
B
C
B
C
E E
E E
E
E
F
F
F J
H H H H H
H H H H H
A3.16
A3.14
A3.24
RESIDENTFL#00
RESIDENTFL#01
RESIDENTFL#02
RESIDENTFL#03
RESIDENTFL#04
RESIDENTFL#05
RESIDENTFL#06
RESIDENTFL#07
RESIDENTFL#08
RESIDENTFL#09
RESIDENTFL#10
RESIDENTFL#11
RESIDENTFL#12
COMMUNITYFL#13CUST
FL#14
WOMENFL#15
ELECFL#16
CHASEFL#17
HALLHFL#01
HALLHFL#03
HALLHLF#02
A3.11
A3.12
M3D
M3A
S2CS2C
M3D
M3A
M3A M3A
7
1
1
KKKK
K
K
K K K K K
K
K
K
CONSTRUCTION PHASING LINE.
PHASE B CONSTRUCTION AREA
AREA NOT TO BE DISTURBED BYCONSTRUCTION
PHASE A CONSTRUCTION AREA, LIMITEDSCOPE IN PHASE B, SEE ALL NOTES
DEMOLITION - TO BE NOTED ONDEMO PLANS ONLY
EXISTING TEXTURE CEILING(ASBESTOS)
INSTALL NEW VCT AND RUBBER BASE IN TYPICAL CORRIDORS HFL#01,HFL#02, AND HFL#03, FLOORS 2-18, SEE FINISH SCHEDULE.
INSTALL NEW SHAFT WALLS. SEE PARTITION TYPES AND MECHANICALFOR ADDITIONAL SCOPE AND DETAILS. SEE FINISH SCHEDULE.
INSTALL NEW DRYER VENTS. SEE MECHANICAL FOR ADDITIONALDETAILS.
NOT USED.
COORDINATE WITH MECHANICAL, ELECTRICAL, AND PLUMBING FORFULL SCOPE OF DEMOLITION/CONSTRUCTION IN ELECTRICAL ROOMS,PIPE CHASES AND MECHANICAL CHASE.
SEE DEMOLITION RELECTED CEILING PLANS AND REFLECTEDCEILINGS PLANS FOR PHASE A WORK TO OCCUR IN THIS AREA.
PAINT TYPICAL CORRIDORS HFL#01, HFL#02, AND HFL#03, FLOORS 2-18, SEE FINISH SCHEDULE AND PLANS.
1
2
3
4
5
6
7
1. SEE LEGEND. PHASE B AREA AND ADJACENT WALLS ARE NOT TO BE DISTURBEDDURING PHASE A TO PREVENT HAZARDOUS MATERIALS IN WALLS FROM BEINGDISTURBED. THE BOUNDARY WALL SEPARATING PHASE A AND PHASE B IS NOT TOBE DISTURBED DURING PHASE A.2. CONTACT OWNER UPON DISCOVERY OF ANY ASBESTOS-CONTAININGMATERIALS OR OTHER SUSPECTED HAZARDOUS MATERIALS NOT SHOWN TO BEREMOVED OR ALTERED WITHIN THE PROJECT SCOPE.3. FIELD VERIFY EXISTING CONDITIONS PRIOR TO COMMENCEMENT OFDEMOLITION AND NEW WORK. INFORMATION SHOWN IS BASED ON THE EXISTINGDRAWINGS PROVIDED BY THE OWNER. GENERAL CONTRACTOR AND SUB-CONTRACTORS ARE TO VERIFY EXISTING CONDITIONS PRIOR TO BID AND PRIORTO CONSTRUCTION.4. CONTRACTOR SHALL PHOTOGRAPH AND VIDEO ALL SPACES PRIOR TOCOMMENCEMENT OF RENOVATION/NEW WORK TO DOCUMENT PRE-CONSTRUCTION CONDITIONS. PROVIDE ARCHITECT WITH ELECTRONIC COPIESOF PHOTOGRAPHS AND VIDEO.5. CORE DRILLING IN EXISTING SLAB FOR NEW UTILITY SERVICE IS NOT SHOWN ONTHIS PLAN. SEE MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FORREQUIRED UTILITY ROUTING.6. SEE MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS FOR ADDITIONALITEMS TO REMAIN AND BE PROTECTED THROUGHOUT CONSTRUCTION,INCLUDING DATA AND POWER CONDUITS, LIGHTS, PIPES AND DUCTWORK.7. ITEMS TO BE SALVAGED AND REMOVED BY OWNER PRIOR TO DEMOLITION AREIDENTIFIED WITHIN THE SPECIFICATIONS.8. PROTECT EXISTING BUILDING SCOPE NOT INCLUDED IN DEMOLITION ORCONSTRUCTION SCOPE, INCLUDING BUT NOT LIMITED TO WALLS, FLOORING,CEILINGS, CASEWORK, AND DOORS. REPAIR OR REPLACE AREAS DAMAGEDDURING DEMOLITION OR CONSTRUCTION WITHIN THE PROJECT SCOPE, WITH NOADDITIONAL COST TO THE OWNER.9. SEE MECHANICAL, PLUMBING AND ELECTRICAL FOR SCOPE AND COORDINATIONOF NEW SYSTEMS.10. SEE PHASE B - FLOOR PLAN KEY NOTES FOR WORK TO OCCUR IN TYPICALCORRIDORS HFL#01, HFL#02, AND HFL#03, FLOORS 2-18, DURING PHASE B OFCONSTRUCTION.11. ELEVATORS ARE NOT PART OF THE PROJECT SCOPE BUT MAY BE USEDDURING THE DEMOLITION AND CONSTRUCTION PERIOD. ELEVATORS SHOULD BEPROTECTED, CLEANED AND RETURNED TO THE CONDITION IN WHICH THEY WEREFOUND AT THE END OF EACH JOB PHASE. SEE SPECIFICATIONS.12. SEE FINISH SCHEDULE AND FINISH PLANS FOR FULL SCOPE OF FINISHES.KEYNOTES REFERRING TO FINISHES ARE FOR PHASING CLARIFICATION.
1. SEE LEGEND. PHASE B AREA AND ADJACENT WALLS ARE NOT TO BE DISTURBEDDURING PHASE A TO PREVENT HAZARDOUS MATERIALS IN WALLS FROM BEINGDISTURBED. THE BOUNDARY WALL SEPARATING PHASE A AND PHASE B IS NOT TOBE DISTURBED DURING PHASE A.2. CONTACT OWNER UPON DISCOVERY OF ANY ASBESTOS-CONTAININGMATERIALS OR OTHER SUSPECTED HAZARDOUS MATERIALS NOT SHOWN TO BEREMOVED OR ALTERED WITHIN THE PROJECT SCOPE.3. FIELD VERIFY EXISTING CONDITIONS PRIOR TO COMMENCEMENT OFDEMOLITION AND NEW WORK. INFORMATION SHOWN IS BASED ON THE EXISTINGDRAWINGS PROVIDED BY THE OWNER. GENERAL CONTRACTOR AND SUB-CONTRACTORS ARE TO VERIFY EXISTING CONDITIONS PRIOR TO BID AND PRIORTO CONSTRUCTION.4. CONTRACTOR SHALL PHOTOGRAPH AND VIDEO ALL SPACES PRIOR TOCOMMENCEMENT OF RENOVATION/NEW WORK TO DOCUMENT PRE-CONSTRUCTION CONDITIONS. PROVIDE ARCHITECT WITH ELECTRONIC COPIESOF PHOTOGRAPHS AND VIDEO.5. CORE DRILLING IN EXISTING SLAB FOR NEW UTILITY SERVICE IS NOT SHOWN ONTHIS PLAN. SEE MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FORREQUIRED UTILITY ROUTING.6. SEE MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS FOR ADDITIONALITEMS TO REMAIN AND BE PROTECTED THROUGHOUT CONSTRUCTION,INCLUDING DATA AND POWER CONDUITS, LIGHTS, PIPES AND DUCTWORK.7. ITEMS TO BE SALVAGED AND REMOVED BY OWNER PRIOR TO DEMOLITION AREIDENTIFIED WITHIN THE SPECIFICATIONS.8. PROTECT EXISTING BUILDING SCOPE NOT INCLUDED IN DEMOLITION ORCONSTRUCTION SCOPE, INCLUDING BUT NOT LIMITED TO WALLS, FLOORING,CEILINGS, CASEWORK, AND DOORS. REPAIR OR REPLACE AREAS DAMAGEDDURING DEMOLITION OR CONSTRUCTION WITHIN THE PROJECT SCOPE, WITH NOADDITIONAL COST TO THE OWNER.9. SEE MECHANICAL, PLUMBING AND ELECTRICAL FOR SCOPE AND COORDINATIONOF NEW SYSTEMS.10. SEE PHASE B - FLOOR PLAN KEY NOTES FOR WORK TO OCCUR IN TYPICALCORRIDORS HFL#01, HFL#02, AND HFL#03, FLOORS 2-18, DURING PHASE B OFCONSTRUCTION.11. ELEVATORS ARE NOT PART OF THE PROJECT SCOPE BUT MAY BE USEDDURING THE DEMOLITION AND CONSTRUCTION PERIOD. ELEVATORS SHOULD BEPROTECTED, CLEANED AND RETURNED TO THE CONDITION IN WHICH THEY WEREFOUND AT THE END OF EACH JOB PHASE. SEE SPECIFICATIONS.12. SEE FINISH SCHEDULE AND FINISH PLANS FOR FULL SCOPE OF FINISHES.KEYNOTES REFERRING TO FINISHES ARE FOR PHASING CLARIFICATION.
INSTALL NEW CARPET AND RUBBER BASE. SEE FINISH SCHEDULEAND FINISH PLAN.
INSTALL INFILL WALL WHERE EXISTING FAN COIL UNIT WASREMOVED. SEE DETAILS 1-4/A3.2.
INSTALL NEW VCT AND BASE AROUND EXISTING RESIDENT ROOMFAN COIL UNITS AND VANITIES TO NEAREST FULL TILE, 2''-4" MIN.SEE FINISH SCHEDULE AND PLANS.
INSTALL NEW FLOORING. SEE FINISH SCHEDULE AND PLANS.
INSTALL NEW WALL, SEE PARTITION TYPES AND FINISH SCHEDULE.
PAINT TYPICAL CORRIDORS HFL#01, HFL#02, AND HFL#03, FLOORS2-18. SEE FINISH SCHEDULE AND FINISH PLANS.
NOT USED.
PROTECT EDGE OF CASEWORK THROUGHOUTDEMOLITION/CONSTRUCTION. INSTALL NEW FINISHED CASEWORKEDGE WHERE VANITIES HAVE BEEN REMOVED AS SHOWN IN DETAIL6/A3.1.
INSTALL PEM ALL EXTINGUISHING SYSTEM IN EXISTING CABINET,SEE MECHANICAL. PROVIDE AND INSTALL NEW LOCK ON EXISTINGOVERHEAD CABINET, SEE SPECS.
PAINT TYPICAL RESIDENCE AND COMMUNITY ROOMS. SEE FINISHSCHEDULE AND FINISH PLANS.
A
B
C
D
E
F
G
H
J
K
N
PHASE B WORK - NOTE TO CONTRACTORS:
1. DURING THE PROCESS OF INSTALLING HANGERS, SOFFITS, FAN COILS, METAL PAN COVERS, NEW PARTITIONS OR ANY OTHERMATERIAL OR EQUIPMENT AT THE CEILINGS OF THE EXISTING RESIDENT ROOMS ON FLOORS 2 THRU 18, THE CONTRACTORSHALL NOT COME IN CONTACT WITH THE SPRAY APPLIED TEXTURED CEILING MATERIAL THAT IS TO REMAIN IN PLACE AFTER THEPARTIAL ABATEMENT OF ASBESTOS FROM THE CEILINGS. CONTAMINATION OF THESE SPACES CAUSED BY DAMAGE TO THECEILING MATERIAL SHALL BE CLEANED UP AT THE CONTRACTOR'S EXPENSE, INCLUDING BUT NOT LIMITED TO, COSTSASSOCIATED WITH CLEARING THESE SPACES FOR RE-ACCESS, I.E. AIR SAMPLING.
2. DURING THE PROCESS OF INSTALLING UL RATED RACEWAYS AT CORRIDOR WALL PENETRATION, INSTALLATION OF NEWPARTITIONS, THE CONTRACTOR SHALL NOT DISTURB THE EXISTING GYPSUM BOARD IN ANY FASHION. NO PENETRATIONS WILLBE ALLOWED ONCE THE ASBESTOS ABATEMENT HAS BEEN COMPLETED BY THE ABATEMENT CONTRACTOR.
PHASE A WORK - NOTE TO CONTRACTORS:
1. NO PENETRATIONS OR ATTACHMENTS TO THE EXISTING GYPSUM BOARD PARTITIONS WILL BE ALLOWED ONCE THEASBESTOS ABATEMENT HAS BEEN COMPLETED BY THE ABATEMENT CONTRACTOR.
2. THE CONTRACTOR SHALL NOT COME IN CONTACT WITH THE GYPSUM BOARD MATERIAL THAT IS TO REMAIN IN PLACE AFTERTHE PARTIAL ABATEMENT OF ASBESTOS FROM THE CORRIDOR PARTITIONS ON THE EXISTING FLOORS 2 THRU 18 AND OTHERPARTITIONS ON THE BASEMENT AND GROUND LEVELS. CONTAMINATION OF THESE SPACES CAUSED BY DAMAGE TO THEGYPSUM BOARD MATERIAL SHALL BE CLEANED UP AT THE CONTRACTOR'S EXPENSE, INCLUDING BUT NOT LIMITED TO, COSTSASSOCIATED WITH CLEARING THESE SPACES FOR RE-ACCESS, I.E. AIR SAMPLING.
REFERENCED ON: 1/4" = 1'-0"A1.21 TYPICAL FLOOR PLAN - LEVEL 2-17
LEGEND
PHASE A - FLOOR PLAN KEYNOTESPHASE A - GENERAL FLOOR PLAN NOTES
PHASE B - GENERAL FLOOR PLAN NOTES PHASE B - FLOOR PLAN KEYNOTES
A1.2
TYPI
CAL F
LOOR
PLA
N -
LEVE
LS 2-
17
RMB
SAL
1
ED
C
2 3 4
BA
1 2 3 4
UNIV
ERSI
TY O
F SO
UTH
CARO
LINA
MECH
ANIC
AL R
ENOV
ATIO
NSSO
UTH
TOW
ER
5 6 7
E
SHEET:
SHEE
T TI
TLE:
DRAW
N BY
:
D
REV.
DRAW
ING:
DESC
RIPT
ION
03/15
/12DA
TE:
PROJ
ECT
TITL
E:
C
CHEC
KED
BY:
DATE
ORIG
. BY
DRAW
N BY
5 6
Facsimile: (803) 791-0830
B
SEAL
SEAL
Swyg
ert &
Ass
ocia
tes
C O
N S
U L
T I
N G
E
N G
I N
E E
R S
Post Office Box 11686
DBA Swygert & Assoc. Ltd.
A
Telephone: (803) 791-9300
Columbia, S.C. 29211
mail@
swygert-associates.com
7
STAT
E PR
OJEC
T NU
MBER
H27
-608
2-NA
THIS DRAWING AND THE
DESIGN THEREON ARE THE
PROPERTY OF SW
YGERT &
ASSOCIATES, LTD. THE
REPRODUC
TION
, COPYING, OR
USE OF THIS DRAWING
WITHOU
T THE WRITTEN
CON
SENT OF SW
YGERT &
ASSOCIATES IS PROHIBITED
AND ANY INFRINGEMENT WILL
BE SUBJECT TO LEGAL ACTION
.
BID
DOCU
MENT
S
DN
DN
UP
RESIDENT1808
RESIDENT1809
RESIDENT1810
RESIDENT1811
RESIDENT1812
COMMUNITY1813
RESIDENT1801
RESIDENT1802
RESIDENT1803
RESIDENT1804RESIDENT
1805
RESIDENT1806
RESIDENT1807
HALLH1803
HALLH1801
HALLH1802
WOMEN1815
CHASE1817
ELEC1816
CUST1814
7 A
7 A
7 A
5
5
B
C
B
C
B
C
B
C
B
C
B
D
B
C
B
C
B
C
B
C
B
C
B
C
B
C
B
C
E E
E E
E
E
F
F
F J
H H H H H
H H H H
RESIDENT1800
6
A3.16
A3.14
A3.24
2
A3.2
A3.11
M3A
M3DM3D
S2CS2C
M3A
M3A M3A
K K K
K
K
KKKKK
K
K
K K
1
1
1
H
CONSTRUCTION PHASING LINE.
PHASE B CONSTRUCTION AREA
AREA NOT TO BE DISTURBED BYCONSTRUCTION
PHASE A CONSTRUCTION AREA, LIMITEDSCOPE IN PHASE B, SEE ALL NOTES
DEMOLITION - TO BE NOTED ONDEMO PLANS ONLY
EXISTING TEXTURE CEILING(ASBESTOS)
INSTALL NEW VCT AND RUBBER BASE IN TYPICAL CORRIDORS HFL#01,HFL#02, AND HFL#03, FLOORS 2-18, SEE FINISH SCHEDULE.
INSTALL NEW SHAFT WALLS. SEE PARTITION TYPES AND MECHANICALFOR ADDITIONAL SCOPE AND DETAILS. SEE FINISH SCHEDULE.
INSTALL NEW DRYER VENTS. SEE MECHANICAL FOR ADDITIONALDETAILS.
NOT USED.
COORDINATE WITH MECHANICAL, ELECTRICAL, AND PLUMBING FORFULL SCOPE OF DEMOLITION/CONSTRUCTION IN ELECTRICAL ROOMS,PIPE CHASES AND MECHANICAL CHASE.
SEE DEMOLITION RELECTED CEILING PLANS AND REFLECTEDCEILINGS PLANS FOR PHASE A WORK TO OCCUR IN THIS AREA.
PAINT TYPICAL CORRIDORS HFL#01, HFL#02, AND HFL#03, FLOORS 2-18, SEE FINISH SCHEDULE AND PLANS.
1
2
3
4
5
6
7
INSTALL NEW CARPET AND RUBBER BASE. SEE FINISH SCHEDULEAND FINISH PLAN.
INSTALL INFILL WALL WHERE EXISTING FAN COIL UNIT WASREMOVED. SEE DETAILS 1-4/A3.2.
INSTALL NEW VCT AND BASE AROUND EXISTING RESIDENT ROOMFAN COIL UNITS AND VANITIES TO NEAREST FULL TILE, 2''-4" MIN.SEE FINISH SCHEDULE AND PLANS.
INSTALL NEW FLOORING. SEE FINISH SCHEDULE AND PLANS.
INSTALL NEW WALL, SEE PARTITION TYPES AND FINISH SCHEDULE.
PAINT TYPICAL CORRIDORS HFL#01, HFL#02, AND HFL#03, FLOORS2-18. SEE FINISH SCHEDULE AND FINISH PLANS.
NOT USED.
PROTECT EDGE OF CASEWORK THROUGHOUTDEMOLITION/CONSTRUCTION. INSTALL NEW FINISHED CASEWORKEDGE WHERE VANITIES HAVE BEEN REMOVED AS SHOWN IN DETAIL6/A3.1.
INSTALL PEM ALL EXTINGUISHING SYSTEM IN EXISTING CABINET,SEE MECHANICAL. PROVIDE AND INSTALL NEW LOCK ON EXISTINGOVERHEAD CABINET, SEE SPECS.
PAINT TYPICAL RESIDENCE AND COMMUNITY ROOMS. SEE FINISHSCHEDULE AND FINISH PLANS.
A
B
C
D
E
F
G
H
J
K
1. SEE LEGEND. PHASE B AREA AND ADJACENT WALLS ARE NOT TO BE DISTURBEDDURING PHASE A TO PREVENT HAZARDOUS MATERIALS IN WALLS FROM BEINGDISTURBED. THE BOUNDARY WALL SEPARATING PHASE A AND PHASE B IS NOT TOBE DISTURBED DURING PHASE A.2. CONTACT OWNER UPON DISCOVERY OF ANY ASBESTOS-CONTAININGMATERIALS OR OTHER SUSPECTED HAZARDOUS MATERIALS NOT SHOWN TO BEREMOVED OR ALTERED WITHIN THE PROJECT SCOPE.3. FIELD VERIFY EXISTING CONDITIONS PRIOR TO COMMENCEMENT OFDEMOLITION AND NEW WORK. INFORMATION SHOWN IS BASED ON THE EXISTINGDRAWINGS PROVIDED BY THE OWNER. GENERAL CONTRACTOR AND SUB-CONTRACTORS ARE TO VERIFY EXISTING CONDITIONS PRIOR TO BID AND PRIORTO CONSTRUCTION.4. CONTRACTOR SHALL PHOTOGRAPH AND VIDEO ALL SPACES PRIOR TOCOMMENCEMENT OF RENOVATION/NEW WORK TO DOCUMENT PRE-CONSTRUCTION CONDITIONS. PROVIDE ARCHITECT WITH ELECTRONIC COPIESOF PHOTOGRAPHS AND VIDEO.5. CORE DRILLING IN EXISTING SLAB FOR NEW UTILITY SERVICE IS NOT SHOWN ONTHIS PLAN. SEE MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FORREQUIRED UTILITY ROUTING.6. SEE MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS FOR ADDITIONALITEMS TO REMAIN AND BE PROTECTED THROUGHOUT CONSTRUCTION,INCLUDING DATA AND POWER CONDUITS, LIGHTS, PIPES AND DUCTWORK.7. ITEMS TO BE SALVAGED AND REMOVED BY OWNER PRIOR TO DEMOLITION AREIDENTIFIED WITHIN THE SPECIFICATIONS.8. PROTECT EXISTING BUILDING SCOPE NOT INCLUDED IN DEMOLITION ORCONSTRUCTION SCOPE, INCLUDING BUT NOT LIMITED TO WALLS, FLOORING,CEILINGS, CASEWORK, AND DOORS. REPAIR OR REPLACE AREAS DAMAGEDDURING DEMOLITION OR CONSTRUCTION WITHIN THE PROJECT SCOPE, WITH NOADDITIONAL COST TO THE OWNER.9. SEE MECHANICAL, PLUMBING AND ELECTRICAL FOR SCOPE AND COORDINATIONOF NEW SYSTEMS.10. SEE PHASE B - FLOOR PLAN KEY NOTES FOR WORK TO OCCUR IN TYPICALCORRIDORS HFL#01, HFL#02, AND HFL#03, FLOORS 2-18, DURING PHASE B OFCONSTRUCTION.11. ELEVATORS ARE NOT PART OF THE PROJECT SCOPE BUT MAY BE USEDDURING THE DEMOLITION AND CONSTRUCTION PERIOD. ELEVATORS SHOULD BEPROTECTED, CLEANED AND RETURNED TO THE CONDITION IN WHICH THEY WEREFOUND AT THE END OF EACH JOB PHASE. SEE SPECIFICATIONS.12. SEE FINISH SCHEDULE AND FINISH PLANS FOR FULL SCOPE OF FINISHES.KEYNOTES REFERRING TO FINISHES ARE FOR PHASING CLARIFICATION.
1. SEE LEGEND. PHASE B AREA AND ADJACENT WALLS ARE NOT TO BE DISTURBEDDURING PHASE A TO PREVENT HAZARDOUS MATERIALS IN WALLS FROM BEINGDISTURBED. THE BOUNDARY WALL SEPARATING PHASE A AND PHASE B IS NOT TOBE DISTURBED DURING PHASE A.2. CONTACT OWNER UPON DISCOVERY OF ANY ASBESTOS-CONTAININGMATERIALS OR OTHER SUSPECTED HAZARDOUS MATERIALS NOT SHOWN TO BEREMOVED OR ALTERED WITHIN THE PROJECT SCOPE.3. FIELD VERIFY EXISTING CONDITIONS PRIOR TO COMMENCEMENT OFDEMOLITION AND NEW WORK. INFORMATION SHOWN IS BASED ON THE EXISTINGDRAWINGS PROVIDED BY THE OWNER. GENERAL CONTRACTOR AND SUB-CONTRACTORS ARE TO VERIFY EXISTING CONDITIONS PRIOR TO BID AND PRIORTO CONSTRUCTION.4. CONTRACTOR SHALL PHOTOGRAPH AND VIDEO ALL SPACES PRIOR TOCOMMENCEMENT OF RENOVATION/NEW WORK TO DOCUMENT PRE-CONSTRUCTION CONDITIONS. PROVIDE ARCHITECT WITH ELECTRONIC COPIESOF PHOTOGRAPHS AND VIDEO.5. CORE DRILLING IN EXISTING SLAB FOR NEW UTILITY SERVICE IS NOT SHOWN ONTHIS PLAN. SEE MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FORREQUIRED UTILITY ROUTING.6. SEE MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS FOR ADDITIONALITEMS TO REMAIN AND BE PROTECTED THROUGHOUT CONSTRUCTION,INCLUDING DATA AND POWER CONDUITS, LIGHTS, PIPES AND DUCTWORK.7. ITEMS TO BE SALVAGED AND REMOVED BY OWNER PRIOR TO DEMOLITION AREIDENTIFIED WITHIN THE SPECIFICATIONS.8. PROTECT EXISTING BUILDING SCOPE NOT INCLUDED IN DEMOLITION ORCONSTRUCTION SCOPE, INCLUDING BUT NOT LIMITED TO WALLS, FLOORING,CEILINGS, CASEWORK, AND DOORS. REPAIR OR REPLACE AREAS DAMAGEDDURING DEMOLITION OR CONSTRUCTION WITHIN THE PROJECT SCOPE, WITH NOADDITIONAL COST TO THE OWNER.9. SEE MECHANICAL, PLUMBING AND ELECTRICAL FOR SCOPE AND COORDINATIONOF NEW SYSTEMS.10. SEE PHASE B - FLOOR PLAN KEY NOTES FOR WORK TO OCCUR IN TYPICALCORRIDORS HFL#01, HFL#02, AND HFL#03, FLOORS 2-18, DURING PHASE B OFCONSTRUCTION.11. ELEVATORS ARE NOT PART OF THE PROJECT SCOPE BUT MAY BE USEDDURING THE DEMOLITION AND CONSTRUCTION PERIOD. ELEVATORS SHOULD BEPROTECTED, CLEANED AND RETURNED TO THE CONDITION IN WHICH THEY WEREFOUND AT THE END OF EACH JOB PHASE. SEE SPECIFICATIONS.12. SEE FINISH SCHEDULE AND FINISH PLANS FOR FULL SCOPE OF FINISHES.KEYNOTES REFERRING TO FINISHES ARE FOR PHASING CLARIFICATION.
N
PHASE A WORK - NOTE TO CONTRACTORS:
1. NO PENETRATIONS OR ATTACHMENTS TO THE EXISTING GYPSUM BOARD PARTITIONS WILL BE ALLOWED ONCE THEASBESTOS ABATEMENT HAS BEEN COMPLETED BY THE ABATEMENT CONTRACTOR.
2. THE CONTRACTOR SHALL NOT COME IN CONTACT WITH THE GYPSUM BOARD MATERIAL THAT IS TO REMAIN IN PLACE AFTERTHE PARTIAL ABATEMENT OF ASBESTOS FROM THE CORRIDOR PARTITIONS ON THE EXISTING FLOORS 2 THRU 18 AND OTHERPARTITIONS ON THE BASEMENT AND GROUND LEVELS. CONTAMINATION OF THESE SPACES CAUSED BY DAMAGE TO THEGYPSUM BOARD MATERIAL SHALL BE CLEANED UP AT THE CONTRACTOR'S EXPENSE, INCLUDING BUT NOT LIMITED TO, COSTSASSOCIATED WITH CLEARING THESE SPACES FOR RE-ACCESS, I.E. AIR SAMPLING.
PHASE B WORK - NOTE TO CONTRACTORS:
1. DURING THE PROCESS OF INSTALLING HANGERS, SOFFITS, FAN COILS, METAL PAN COVERS, NEW PARTITIONS OR ANY OTHERMATERIAL OR EQUIPMENT AT THE CEILINGS OF THE EXISTING RESIDENT ROOMS ON FLOORS 2 THRU 18, THE CONTRACTORSHALL NOT COME IN CONTACT WITH THE SPRAY APPLIED TEXTURED CEILING MATERIAL THAT IS TO REMAIN IN PLACE AFTER THEPARTIAL ABATEMENT OF ASBESTOS FROM THE CEILINGS. CONTAMINATION OF THESE SPACES CAUSED BY DAMAGE TO THECEILING MATERIAL SHALL BE CLEANED UP AT THE CONTRACTOR'S EXPENSE, INCLUDING BUT NOT LIMITED TO, COSTSASSOCIATED WITH CLEARING THESE SPACES FOR RE-ACCESS, I.E. AIR SAMPLING.
2. DURING THE PROCESS OF INSTALLING UL RATED RACEWAYS AT CORRIDOR WALL PENETRATION, INSTALLATION OF NEWPARTITIONS, THE CONTRACTOR SHALL NOT DISTURB THE EXISTING GYPSUM BOARD IN ANY FASHION. NO PENETRATIONS WILLBE ALLOWED ONCE THE ASBESTOS ABATEMENT HAS BEEN COMPLETED BY THE ABATEMENT CONTRACTOR.
REFERENCED ON: 1/4" = 1'-0"A1.31 18TH FLOOR PLAN
LEGEND
PHASE A - FLOOR PLAN KEYNOTES
PHASE B - FLOOR PLAN KEYNOTESPHASE B - GENERAL FLOOR PLAN NOTES
PHASE A - GENERAL FLOOR PLAN NOTES
A1.3
18TH
FLO
OR P
LAN
RMB
SAL
1
ED
C
2 3 4
BA
1 2 3 4
UNIV
ERSI
TY O
F SO
UTH
CARO
LINA
MECH
ANIC
AL R
ENOV
ATIO
NSSO
UTH
TOW
ER
5 6 7
E
SHEET:
SHEE
T TI
TLE:
DRAW
N BY
:
D
REV.
DRAW
ING:
DESC
RIPT
ION
03/15
/12DA
TE:
PROJ
ECT
TITL
E:
C
CHEC
KED
BY:
DATE
ORIG
. BY
DRAW
N BY
5 6
Facsimile: (803) 791-0830
B
SEAL
SEAL
Swyg
ert &
Ass
ocia
tes
C O
N S
U L
T I
N G
E
N G
I N
E E
R S
Post Office Box 11686
DBA Swygert & Assoc. Ltd.
A
Telephone: (803) 791-9300
Columbia, S.C. 29211
mail@
swygert-associates.com
7
STAT
E PR
OJEC
T NU
MBER
H27
-608
2-NA
THIS DRAWING AND THE
DESIGN THEREON ARE THE
PROPERTY OF SW
YGERT &
ASSOCIATES, LTD. THE
REPRODUC
TION
, COPYING, OR
USE OF THIS DRAWING
WITHOU
T THE WRITTEN
CON
SENT OF SW
YGERT &
ASSOCIATES IS PROHIBITED
AND ANY INFRINGEMENT WILL
BE SUBJECT TO LEGAL ACTION
.
BID
DOCU
MENT
S
DN
UP
DN
COMM.1901
ELEV SHAFT1902
RD RD
RDRD
SLO
PE
RIDGERIDGE
SLO
PE SLO
PESL
OPE
SLO
PE
SLO
PESL
OPE
SLO
PE
SLO
PE
SLO
PE
SLO
PE
SLO
PE
SLO
PE
SLO
PE
SLO
PE
SLO
PE
SLO
PE
SLO
PE
SLO
PE
SLO
PE
SLO
PE
SLO
PESL
OPE
SLO
PESL
OPE
SLO
PE
SLO
PE
SLO
PE
SLO
PE
SLO
PESL
OPE
SLO
PESL
OPE
SLOPE
SLOPE
+3"
+7.35"
+3"
+7.35"
+6.78"
+4.26"
+3.76"
+7.82"
1
1
1
1
2
2
2
2
3
4 4
4
4
5
6
7
67
67
67
9
9 9
9
10
A
12
A3.2
14
A3.2
A 13
A3.2
11
12
SLO
PE
SLOPESLOPE
SLO
PE
10
A3.2
9
9
9
9
8
8
8
8
ELEV EQUIP1903
1. SEE LEGEND FOR GENERAL PHASING INDICATIONS. PHASE B AREA AND ADJACENT WALLS ARE NOT TO BE DISTURBED DURING PHASE A TOPREVENT PHASE B HAZARDOUS MATERIALS FROM BEING DISTURBED. THE BOUNDARY WALL SEPARATING PHASE A AND PHASE B IS NOT TO BEDISTURBED DURING PHASE A.2. CONTACT OWNER UPON DISCOVERY OF ANY ASBESTOS-CONTAINING MATERIALS OR OTHER SUSPECTED HAZARDOUS MATERIALS NOTSHOWN TO BE REMOVED OR ALTERED WITHIN THE PROJECT SCOPE.3. FIELD VERIFY EXISTING CONDITIONS PRIOR TO COMMENCEMENT OF DEMOLITION AND NEW WORK. INFORMATION SHOWN IS BASED ON THEEXISTING DRAWINGS PROVIDED BY THE OWNER. GENERAL CONTRACTOR AND SUB-CONTRACTORS ARE TO VERIFY EXISTING CONDITIONSPRIOR TO BID AND PRIOR TO CONSTRUCTION.4. CONTRACTOR SHALL PHOTOGRAPH AND VIDEO ALL SPACES PRIOR TO COMMENCEMENT OF DEMOLITION/RENOVATION/NEW WORK TODOCUMENT PRE-CONSTRUCTION CONDITIONS. PROVIDE ARCHITECT WITH ELECTRONIC COPIES OF PHOTOGRAPHS AND VIDEO.5. CORE DRILLING IN EXISTING SLAB FOR NEW UTILITY SERVICE IS NOT SHOWN ON THIS PLAN. SEE MECHANICAL, PLUMBING, AND ELECTRICALDRAWINGS FOR REQUIRED UTILITY ROUTING.6. SEE MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS FOR ADDITIONAL ITEMS TO REMAIN AND BE PROTECTED THROUGHOUTCONSTRUCTION, INCLUDING DATA AND POWER CONDUITS, LIGHTS, PIPES AND DUCTWORK.7. ITEMS TO BE SALVAGED AND REMOVED BY OWNER PRIOR TO DEMOLITION ARE IDENTIFIED WITHIN THE SPECIFICATIONS.8. PROTECT EXISTING BUILDING SCOPE NOT INCLUDED IN DEMOLITION/CONSTRUCTION WORK. REPAIR OR REPLACEMENT OF DAMAGEDAREAS NOT IN THE SCOPE OF WORK, SHALL BE INCLUDED IN THE WORK , WITH NO ADDITIONAL COST TO THE OWNER.9. PROVIDE AND INSTALL ALL SHORING AND SUPPORT SYSTEMS NECESSARY TO ENSURE EXISTING STRUCTURE TO REMAIN IS STABLETHROUGHOUT DEMOLITION AND CONSTRUCTION.10. ALL DEMOLITION REQUIRED FOR FUTURE INSTALLATION OF MECHANICAL CHASES TO BE COORDINATED WITH MECHANICAL DRAWINGS,EQUIPMENT SPECIFICATIONS, AND STRUCTURAL DRAWINGS.11. PROTECT EXISTING CONCRETE STRUCTURE TO REMAIN THROUGHOUT DEMOLITION/CONSTRUCTION.12. SEE STRUCTURAL DRAWINGS FOR ADDITIONAL INFORMATION REGARDING THE AREAS OF THE EXISTING CONCRETE ROOF STRUCTUREAND CONSTRUCTION TO BE REMOVED.13. 4" FIBER CANTS ALONG PARAPET AND VERTICAL WALL PERIMETER, TYP.14. PRESLOPED RIGID INSULATION AT CRICKETS TO DRAIN WITH SLOPE OF 1/2" PER FOOT MINIMUM. MEASURED AT VALLEY CONDITIONS -SLOPE OF INSULATION BETWEEN ROOF DRAIN AND SCUPPER 1/4" PER FOOT MIN. UNLESS NOTED OTHERWISE.15. INSTALL NEW ROOFING SYSTEM, SEE SPECS.16. SEE PHASE B - GENERAL DEMOLITION ROOF NOTES AND SHEET A1.4 FOR PHASE B ROOF SCOPE.17. GENERAL CONTRACTOR, ROOFING SUBCONTRACTOR AND ASBESTOS ABATEMENT SUBCONTRACTOR SHALL COORDINATE TO ENSUREROOF IS WATERTIGHT THROUGHOUT DEMOLITION AND CONSTRUCTION, INCLUDING ANY TEMPORARY MEASURES REQUIRED TO MAINTAINIMPERMEABILITY THROUGHOUT SCOPE OF WORK.
NEW ROOFING SYSTEM INCLUDING FLASHING, AND ALL OTHER ROOFINGMATERIALS. SEE ROOF DETAILS AND SPECIFICATIONS FOR INFORMATION.
NEW ROOF DRAIN, SEE PLUMBING.
REINSTALL METAL STAIR AT COMPLETION OF ROOF INSTALLATION.
CONC. SPLASH BLOCK, TYP.
REMOVE PARTIAL ROOF DECK FOR INSTALLATION OF NEW MECHANICAL CHASES.COORDINATE WITH MECHANICAL, EQUIPMENT SPEC., AND STRUCTURAL.
NEW OVERFLOW SCUPPER, SEE DETAILS 14/A3.2 & 15/A3.2.
REINSTALL EXISTING PARAPET WALL LOVERS AT COMPLETION OF OVERFLOWSCUPPER INSTALLATION.
CONTINUOUS 4"X4" GUTTER - SEE SPECS AND DETAIL 10/A3.2.
3X4 DOWNLEADER, EXTEND FROM GUTTER TO ROOF BELOW, SEE SPECS.
DISCONNECT AND TEMPORARILY RELOCATE EXISTING MECHANICAL UNIT TOALLOW FOR INSTALLATION OF ROOFING. REINSTALL AFTER ROOFING, SEEMECHANICAL.
NEW STRUCTURAL BRACE, SEE STRUCTURAL.
NEW ROOF CURB, SEE MECHANICAL.
1
2
3
4
5
6
7
8
9
10
11
12
1. SEE LEGEND FOR GENERAL PHASING INDICATIONS. PHASE B AREA AND ADJACENT WALLS ARE NOT TO BE DISTURBEDDURING PHASE A TO PREVENT PHASE B HAZARDOUS MATERIALS FROM BEING DISTURBED. THE BOUNDARY WALL SEPARATINGPHASE A AND PHASE B IS NOT TO BE DISTURBED DURING PHASE A.2. CONTACT OWNER UPON DISCOVERY OF ANY ASBESTOS-CONTAINING MATERIALS OR OTHER SUSPECTED HAZARDOUSMATERIALS NOT SHOWN TO BE REMOVED OR ALTERED WITHIN THE PROJECT SCOPE.3. FIELD VERIFY EXISTING CONDITIONS PRIOR TO COMMENCEMENT OF DEMOLITION AND NEW WORK. INFORMATION SHOWN ISBASED ON THE EXISTING DRAWINGS PROVIDED BY THE OWNER. GENERAL CONTRACTOR AND SUB-CONTRACTORS ARE TOVERIFY EXISTING CONDITIONS PRIOR TO BID AND PRIOR TO CONSTRUCTION.4. CONTRACTOR SHALL PHOTOGRAPH AND VIDEO ALL SPACES PRIOR TO COMMENCEMENT OF DEMOLITION/RENOVATION/NEWWORK TO DOCUMENT PRE-CONSTRUCTION CONDITIONS. PROVIDE ARCHITECT WITH ELECTRONIC COPIES OF PHOTOGRAPHSAND VIDEO.5. CORE DRILLING IN EXISTING SLAB FOR NEW UTILITY SERVICE IS NOT SHOWN ON THIS PLAN. SEE MECHANICAL, PLUMBING,AND ELECTRICAL DRAWINGS FOR REQUIRED UTILITY ROUTING.6. SEE MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS FOR ADDITIONAL ITEMS TO REMAIN AND BE PROTECTEDTHROUGHOUT CONSTRUCTION, INCLUDING DATA AND POWER CONDUITS, LIGHTS, PIPES AND DUCTWORK.7. ITEMS TO BE SALVAGED AND REMOVED BY OWNER PRIOR TO DEMOLITION ARE IDENTIFIED WITHIN THE SPECIFICATIONS.8. PROTECT EXISTING BUILDING SCOPE NOT INCLUDED IN DEMOLITION/CONSTRUCTION WORK. REPAIR OR REPLACEMENT OFDAMAGED AREAS NOT IN THE SCOPE OF WORK, SHALL BE INCLUDED IN THE WORK , WITH NO ADDITIONAL COST TO THEOWNER.9. PROVIDE AND INSTALL ALL SHORING AND SUPPORT SYSTEMS NECESSARY TO ENSURE EXISTING STRUCTURE TO REMAIN ISSTABLE THROUGHOUT DEMOLITION AND CONSTRUCTION.10. ALL DEMOLITION REQUIRED FOR FUTURE INSTALLATION OF MECHANICAL CHASES TO BE COORDINATED WITH MECHANICALDRAWINGS, EQUIPMENT SPECIFICATIONS, AND STRUCTURAL DRAWINGS.11. PROTECT EXISTING CONCRETE STRUCTURE TO REMAIN THROUGHOUT DEMOLITION/CONSTRUCTION.12. SEE STRUCTURAL DRAWINGS FOR ADDITIONAL INFORMATION REGARDING THE AREAS OF THE EXISTING CONCRETE ROOFSTRUCTURE AND CONSTRUCTION TO BE REMOVED.13. 4" FIBER CANTS ALONG PARAPET AND VERTICAL WALL PERIMETER, TYP.14. PRESLOPED RIGID INSULATION AT CRICKETS TO DRAIN WITH SLOPE OF 1/2" PER FOOT MINIMUM. MEASURED AT VALLEYCONDITIONS - SLOPE OF INSULATION BETWEEN ROOF DRAIN AND SCUPPER 1/4" PER FOOT MIN. UNLESS NOTED OTHERWISE.15. INSTALL NEW ROOFING SYSTEM, SEE SPECS.16. ALL WORK PERFORMED IN PHASE A TO REMAIN. PROTECT THROUGHOUT PHASE B.
LIMITED SCOPE B INCLUDES INSTALLATION OF NEW MECHANICALUNIT AND ASSOCIATED DUCTWORK ON EXISTING CURB ALTEREDIN PHASE A AND ROOF PENETRATION CREATED AND CAPPED INPHASE A. SEE MECHANICAL, ELECTRICAL AND PLUMBING FORADDITIONAL SCOPE RELATED TO PHASE B.
A
N
PHASE B WORK - NOTE TO CONTRACTORS:
1. DURING THE PROCESS OF INSTALLING HANGERS, SOFFITS, FAN COILS, METAL PAN COVERS, NEW PARTITIONS OR ANY OTHERMATERIAL OR EQUIPMENT AT THE CEILINGS OF THE EXISTING RESIDENT ROOMS ON FLOORS 2 THRU 18, THE CONTRACTORSHALL NOT COME IN CONTACT WITH THE SPRAY APPLIED TEXTURED CEILING MATERIAL THAT IS TO REMAIN IN PLACE AFTER THEPARTIAL ABATEMENT OF ASBESTOS FROM THE CEILINGS. CONTAMINATION OF THESE SPACES CAUSED BY DAMAGE TO THECEILING MATERIAL SHALL BE CLEANED UP AT THE CONTRACTOR'S EXPENSE, INCLUDING BUT NOT LIMITED TO, COSTSASSOCIATED WITH CLEARING THESE SPACES FOR RE-ACCESS, I.E. AIR SAMPLING.
2. DURING THE PROCESS OF INSTALLING UL RATED RACEWAYS AT CORRIDOR WALL PENETRATION, INSTALLATION OF NEWPARTITIONS, THE CONTRACTOR SHALL NOT DISTURB THE EXISTING GYPSUM BOARD IN ANY FASHION. NO PENETRATIONS WILLBE ALLOWED ONCE THE ASBESTOS ABATEMENT HAS BEEN COMPLETED BY THE ABATEMENT CONTRACTOR.
PHASE A WORK - NOTE TO CONTRACTORS:
1. NO PENETRATIONS OR ATTACHMENTS TO THE EXISTING GYPSUM BOARD PARTITIONS WILL BE ALLOWED ONCE THEASBESTOS ABATEMENT HAS BEEN COMPLETED BY THE ABATEMENT CONTRACTOR.
2. THE CONTRACTOR SHALL NOT COME IN CONTACT WITH THE GYPSUM BOARD MATERIAL THAT IS TO REMAIN IN PLACE AFTERTHE PARTIAL ABATEMENT OF ASBESTOS FROM THE CORRIDOR PARTITIONS ON THE EXISTING FLOORS 2 THRU 18 AND OTHERPARTITIONS ON THE BASEMENT AND GROUND LEVELS. CONTAMINATION OF THESE SPACES CAUSED BY DAMAGE TO THEGYPSUM BOARD MATERIAL SHALL BE CLEANED UP AT THE CONTRACTOR'S EXPENSE, INCLUDING BUT NOT LIMITED TO, COSTSASSOCIATED WITH CLEARING THESE SPACES FOR RE-ACCESS, I.E. AIR SAMPLING.
REFERENCED ON: 1/4" = 1'-0"A1.41 ROOF PLAN
REFERENCED ON: 1/4" = 1'-0"A1.42 PENTHOUSE ROOF PLAN
REFERENCED ON: 1/4" = 1'-0"A1.43 PENTHOUSE FLOOR PLAN
PHASE A - GENERAL ROOF PLAN NOTES PHASE A - TYPICAL ROOF PLAN KEYNOTES PHASE A - GENERAL DEMOLITION ROOF NOTES
A1.4
ROOF
PLA
NRM
BSA
L
PHASE B - ROOF PLAN KEYNOTES
1
ED
C
2 3 4
BA
1 2 3 4
UNIV
ERSI
TY O
F SO
UTH
CARO
LINA
MECH
ANIC
AL R
ENOV
ATIO
NSSO
UTH
TOW
ER
5 6 7
E
SHEET:
SHEE
T TI
TLE:
DRAW
N BY
:
D
REV.
DRAW
ING:
DESC
RIPT
ION
03/15
/12DA
TE:
PROJ
ECT
TITL
E:
C
CHEC
KED
BY:
DATE
ORIG
. BY
DRAW
N BY
5 6
Facsimile: (803) 791-0830
B
SEAL
SEAL
Swyg
ert &
Ass
ocia
tes
C O
N S
U L
T I
N G
E
N G
I N
E E
R S
Post Office Box 11686
DBA Swygert & Assoc. Ltd.
A
Telephone: (803) 791-9300
Columbia, S.C. 29211
mail@
swygert-associates.com
7
STAT
E PR
OJEC
T NU
MBER
H27
-608
2-NA
THIS DRAWING AND THE
DESIGN THEREON ARE THE
PROPERTY OF SW
YGERT &
ASSOCIATES, LTD. THE
REPRODUC
TION
, COPYING, OR
USE OF THIS DRAWING
WITHOU
T THE WRITTEN
CON
SENT OF SW
YGERT &
ASSOCIATES IS PROHIBITED
AND ANY INFRINGEMENT WILL
BE SUBJECT TO LEGAL ACTION
.
BID
DOCU
MENT
S
EXPOSED STRUCTURE
OPEN TO ABOVE
OPEN TO ABOVE
OPEN TO ABOVE
SLOPED
OPEN TO ABOVE
EXPOSED STRUCTURE
EXPOSED STRUCTURE
16' - 8"
16' - 8"
EXPOSED STRUCTURE
16' - 8"
16' - 8"
CONSTRUCTION PHASING LINE.
PHASE B CONSTRUCTION AREA
AREA NOT TO BE DISTURBED BYCONSTRUCTION
PHASE A CONSTRUCTION AREA, LIMITEDSCOPE IN PHASE B, SEE ALL NOTES
DEMOLITION - TO BE NOTED ONDEMO PLANS ONLY
EXISTING TEXTURE CEILING(ASBESTOS)
INSTALL NEW SOFFIT. SEE MECHANICAL AND DETAIL 6/A3.2 FOR FULLCOORDINATION AND EXTENT OF SCOPE.
REINSTALL EXISTING LIGHT FIXTURE. SEE ELECTRICAL FOR FULLSCOPE AND COORDINATION OF LIGHTINGDEMOLITION/CONSTRUCTION FOR BASE BID AND ALTERNATE NO. 1.
SEE ELECTRICAL DRAWINGS FOR FULL SCOPE AND COORDINATIONOF ALL LIGTHING DEMOLLITION/CONSTRUCTION FOR BASE BID ANDALTERNATE NO. 1.
NEW FAN COIL UNIT. SEE MECHANICAL.
EXISTING LIGHT TO REMAIN. G.C. TO VERIFY EXISTING LOCATIONSARE NOT IN CONFLICT WITH NEW MECHANICAL SYSTEMS PRIOR TOEND OF ASBESTOS ABATEMENT DEMOLITION, TYP. G.C. TORELOCATE AND COORDINATE NEW LOCATION WITH ARCHITECT INFIELD, IF IN CONFLICT WITH NEW MECHANICAL. SEE ELECTRICAL FORFULL SCOPE AND COORDINATION OF LIGHTINGDEMOLITION/CONSTRUCTION FOR BASE BID AND ALTERNATE NO. 1.
NEW METAL PIPE ENCLOSURE. FIELD VERIFY AND COORDINATEDIMENSIONS AND LAYOUT WITH MECHANICAL PIPING ANDELECTRICAL. SEE DETAIL 8/A3.2.
APPLY SPRAY TEXTURE FINISH TO MATCH EXISTING ADJACENTCEILING WHERE EXISTING METAL SOFFIT HAS BEEN DECREASED INSIZE AND UNDERSIDE OF DECK /CEILING HAS BEEN EXPOSED. SEESPEC.
INSTALL NEW STEEL SUPPORT ANGLE AND NEW METAL SOFFIT. SEEDETAIL 7/A3.2 FOR FULL COORDINATION AND EXTENT OF SCOPE.
SELECTIVE REMOVAL OF APC CEILING TILE ONLY INSTALLED INPHASE A TO ALLOW FOR REQUIRED MECHANICAL, ELECTRICAL ANDPLUMBING CONNECTIONS AND/OR REMOVAL OF PIPING. SEEMECHANICAL, ELECRICAL, AND PLUMBING. PROTECT EXISTINGCEILING TILE, GRID AND AND ADJACENT CEILING MATERIALS ANDREINSTALL CEILING TILE AFTER REMOVAL OF PHASE B PLUMBINGSCOPE IS COMPLETE.
A
B
C
D
E
F
G
H
J
INSTALL GRID AND 2'X2' ACT CEILING, SEE FINISHSCHEDULE. SEE ELECTRICAL FOR NEW LIGHTS. (EXISTINGAPC WALL ANGLE TO REMAIN, SEE DEMOLITION KEYNOTES.)
PAINT EXISTING METAL PERIMETER SOFFIT ENTIREPERIMETER OF BUILDING.
INSTALL NEW GWB CEILING TO MATCH EXISTING. NEWLIGHTS, SEE ELECTRICAL.
EXISTING GRILL TO BE REMOVED AND GWB BOARD TO BEPATCHED BY OWNERS. G.C. TO PAINT AT EXPOSED AREAS.
OPENING IN CONCRETE ROOF DECK TO BE CUT ANDCAPPED IN PHASE A. PROVIDE SHEET ROCK SOFFIT INPHASE A TO CONCEAL ROOF OPENING. EXISTING CHASEWALL TO REMAIN DURING PHASE A. SEE DETAIL 2/A2.3 FORPHASE A SOFFIT PLAN.
1
2
3
4
5
1. SEE PHASING LEGEND. PHASE B AREA AND ADJACENT WALLS ARE NOT TO BEDISTURBED DURING PHASE A TO PREVENT PHASE B HAZARDOUS MATERIALS FROMBEING DISTURBED. THE BOUNDARY WALL SEPARATING PHASE A AND PHASE B IS NOTTO BE DISTURBED DURING PHASE A.2. CONTACT OWNER UPON DISCOVERY OF ANY ASBESTOS-CONTAINING MATERIALSOR OTHER SUSPECTED HAZARDOUS MATERIALS NOT SHOW TO BE REMOVED ORALTERED WITHIN THE PROJECT SCOPE.3. FIELD VERIFY EXISTING CONDITIONS PRIOR TO COMMENCEMENT OF DEMOLITIONAND NEW WORK. INFORMATION SHOWN IS BASED ON THE EXISTING DRAWINGSPROVIDED BY THE OWNER. GENERAL CONTRACTOR AND SUB-CONTRACTORS ARE TOVERIFY EXISTING CONDITIONS PRIOR TO BID AND PRIOR TO CONSTRUCTION.4. CONTRACTOR SHALL PHOTOGRAPH AND VIDEO ALL SPACES PRIOR TOCOMMENCEMENT OF RENOVATION/NEW WORK TO DOCUMENT PRE-CONSTRUCTIONCONDITIONS. PROVIDE ARCHITECT WITH ELECTRONIC COPIES OF PHOTOGRAPHSAND VIDEO.5. CORE DRILLING IN EXISTING SLAB FOR NEW UTILITY SERVICE IS NOT SHOWN ONTHIS PLAN. SEE MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FOR REQUIREDUTILITY ROUTING.6. SEE MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS FOR ADDITIONAL ITEMSTO REMAIN AND BE PROTECTED THROUGHOUT CONSTRUCTION, INCLUDING DATA ANDPOWER CONDUITS, LIGHTS, PIPES AND DUCTWORK.7. ITEMS TO BE SALVAGED AND REMOVED BY OWNER PRIOR TO DEMOLITION AREIDENTIFIED WITHIN THE SPECIFICATIONS.8. PROTECT EXISTING BUILDING SCOPE NOT INCLUDED INDEMOLITION/CONSTRUCTION SCOPE. REPAIR OR REPLACEMENT DAMAGED AREASNOT IN THIS SCOPE SHALL BE INCLUDED IN THE WORK, WITH NO ADDITIONAL COST TOTHE OWNER.9. ELECTRICAL CONTRACTOR IS TO VERIFY ALL CEILING MOUNTED ELECTRICALDEVICES ARE IN WORKING CONDITION AT COMMENCEMENT OFDEMOLITION/CONSTRUCTION. SEE ELECTRICAL DRAWINGS AND SPECS FOR ALLSCOPE RELATED TO CEILING MOUNTED DEVICES PRIOR TO COMMENCEMENT OFDEMOLITION/CONSTRUCTION.10. SEE ELECTRICAL FOR FULL SCOPE AND COORDINATION OF ALL LIGHTINGDEMOLITION/CONSTRUCTION FOR BASE BID AND ALTERNATE NO. 1.11. ELEVATORS ARE NOT PART OF THE PROJECT SCOPE BUT MAY BE USED DURINGTHE DEMOLITION AND CONSTRUCTION PERIOD. ELEVATORS SHOULD BE PROTECTED,CLEANED AND RETURNED TO THE CONDITION IN WHICH THEY WERE FOUND AT THEEND OF EACH JOB PHASE. SEE SPECIFICATIONS.
1. SEE PHASING LEGEND. PHASE B AREA AND ADJACENT WALLS ARE NOT TO BEDISTURBED DURING PHASE A TO PREVENT PHASE B HAZARDOUS MATERIALS FROMBEING DISTURBED. THE BOUNDARY WALL SEPARATING PHASE A AND PHASE B IS NOTTO BE DISTURBED DURING PHASE A.2. CONTACT OWNER UPON DISCOVERY OF ANY ASBESTOS-CONTAINING MATERIALSOR OTHER SUSPECTED HAZARDOUS MATERIALS NOT SHOW TO BE REMOVED ORALTERED WITHIN THE PROJECT SCOPE.3. FIELD VERIFY EXISTING CONDITIONS PRIOR TO COMMENCEMENT OF DEMOLITIONAND NEW WORK. INFORMATION SHOWN IS BASED ON THE EXISTING DRAWINGSPROVIDED BY THE OWNER. GENERAL CONTRACTOR AND SUB-CONTRACTORS ARE TOVERIFY EXISTING CONDITIONS PRIOR TO BID AND PRIOR TO CONSTRUCTION.4. CONTRACTOR SHALL PHOTOGRAPH AND VIDEO ALL SPACES PRIOR TOCOMMENCEMENT OF RENOVATION/NEW WORK TO DOCUMENT PRE-CONSTRUCTIONCONDITIONS. PROVIDE ARCHITECT WITH ELECTRONIC COPIES OF PHOTOGRAPHSAND VIDEO.5. CORE DRILLING IN EXISTING SLAB FOR NEW UTILITY SERVICE IS NOT SHOWN ONTHIS PLAN. SEE MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FOR REQUIREDUTILITY ROUTING.6. SEE MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS FOR ADDITIONAL ITEMSTO REMAIN AND BE PROTECTED THROUGHOUT CONSTRUCTION, INCLUDING DATA ANDPOWER CONDUITS, LIGHTS, PIPES AND DUCTWORK.7. ITEMS TO BE SALVAGED AND REMOVED BY OWNER PRIOR TO DEMOLITION AREIDENTIFIED WITHIN THE SPECIFICATIONS.8. PROTECT EXISTING BUILDING SCOPE NOT INCLUDED INDEMOLITION/CONSTRUCTION SCOPE. REPAIR OR REPLACEMENT DAMAGED AREASNOT IN THIS SCOPE SHALL BE INCLUDED IN THE WORK, WITH NO ADDITIONAL COST TOTHE OWNER.9. ELECTRICAL CONTRACTOR IS TO VERIFY ALL CEILING MOUNTED ELECTRICALDEVICES ARE IN WORKING CONDITION AT COMMENCEMENT OFDEMOLITION/CONSTRUCTION. SEE ELECTRICAL DRAWINGS AND SPECS FOR ALLSCOPE RELATED TO CEILING MOUNTED DEVICES PRIOR TO COMMENCEMENT OFDEMOLITION/CONSTRUCTION.10. SEE ELECTRICAL FOR FULL SCOPE AND COORDINATION OF LIGHTINGDEMOLITION/CONSTRUCTION FOR BASE BID AND ALTERNATE NO. 1.11. ELEVATORS ARE NOT PART OF THE PROJECT SCOPE BUT MAY BE USED DURINGTHE DEMOLITION AND CONSTRUCTION PERIOD. ELEVATORS SHOULD BE PROTECTED,CLEANED AND RETURNED TO THE CONDITION IN WHICH THEY WERE FOUND AT THEEND OF EACH JOB PHASE. SEE SPECIFICATIONS.
N
PHASE A WORK - NOTE TO CONTRACTORS:
1. NO PENETRATIONS OR ATTACHMENTS TO THE EXISTING GYPSUM BOARD PARTITIONS WILL BE ALLOWED ONCE THEASBESTOS ABATEMENT HAS BEEN COMPLETED BY THE ABATEMENT CONTRACTOR.
2. THE CONTRACTOR SHALL NOT COME IN CONTACT WITH THE GYPSUM BOARD MATERIAL THAT IS TO REMAIN IN PLACE AFTERTHE PARTIAL ABATEMENT OF ASBESTOS FROM THE CORRIDOR PARTITIONS ON THE EXISTING FLOORS 2 THRU 18 AND OTHERPARTITIONS ON THE BASEMENT AND GROUND LEVELS. CONTAMINATION OF THESE SPACES CAUSED BY DAMAGE TO THEGYPSUM BOARD MATERIAL SHALL BE CLEANED UP AT THE CONTRACTOR'S EXPENSE, INCLUDING BUT NOT LIMITED TO, COSTSASSOCIATED WITH CLEARING THESE SPACES FOR RE-ACCESS, I.E. AIR SAMPLING.
PHASE B WORK - NOTE TO CONTRACTORS:
1. DURING THE PROCESS OF INSTALLING HANGERS, SOFFITS, FAN COILS, METAL PAN COVERS, NEW PARTITIONS OR ANY OTHERMATERIAL OR EQUIPMENT AT THE CEILINGS OF THE EXISTING RESIDENT ROOMS ON FLOORS 2 THRU 18, THE CONTRACTORSHALL NOT COME IN CONTACT WITH THE SPRAY APPLIED TEXTURED CEILING MATERIAL THAT IS TO REMAIN IN PLACE AFTER THEPARTIAL ABATEMENT OF ASBESTOS FROM THE CEILINGS. CONTAMINATION OF THESE SPACES CAUSED BY DAMAGE TO THECEILING MATERIAL SHALL BE CLEANED UP AT THE CONTRACTOR'S EXPENSE, INCLUDING BUT NOT LIMITED TO, COSTSASSOCIATED WITH CLEARING THESE SPACES FOR RE-ACCESS, I.E. AIR SAMPLING.
2. DURING THE PROCESS OF INSTALLING UL RATED RACEWAYS AT CORRIDOR WALL PENETRATION, INSTALLATION OF NEWPARTITIONS, THE CONTRACTOR SHALL NOT DISTURB THE EXISTING GYPSUM BOARD IN ANY FASHION. NO PENETRATIONS WILLBE ALLOWED ONCE THE ASBESTOS ABATEMENT HAS BEEN COMPLETED BY THE ABATEMENT CONTRACTOR.
REFERENCED ON: 1/4" = 1'-0"A2.001 BASEMENT REFLECTED CEILING PLAN
LEGEND
PHASE B - TYPICAL RCP KEYNOTES
PHASE A - TYPICAL RCP KEYNOTESPHASE A - GENERAL RCP NOTES
PHASE B - GENERAL RCP NOTES
A2.00
BASE
MENT
REFL
ECTE
D CE
ILING
PLA
N
RMB
SAL
1
ED
C
2 3 4
BA
1 2 3 4
UNIV
ERSI
TY O
F SO
UTH
CARO
LINA
MECH
ANIC
AL R
ENOV
ATIO
NSSO
UTH
TOW
ER
5 6 7
E
SHEET:
SHEE
T TI
TLE:
DRAW
N BY
:
D
REV.
DRAW
ING:
DESC
RIPT
ION
03/15
/12DA
TE:
PROJ
ECT
TITL
E:
C
CHEC
KED
BY:
DATE
ORIG
. BY
DRAW
N BY
5 6
Facsimile: (803) 791-0830
B
SEAL
SEAL
Swyg
ert &
Ass
ocia
tes
C O
N S
U L
T I
N G
E
N G
I N
E E
R S
Post Office Box 11686
DBA Swygert & Assoc. Ltd.
A
Telephone: (803) 791-9300
Columbia, S.C. 29211
mail@
swygert-associates.com
7
STAT
E PR
OJEC
T NU
MBER
H27
-608
2-NA
THIS DRAWING AND THE
DESIGN THEREON ARE THE
PROPERTY OF SW
YGERT &
ASSOCIATES, LTD. THE
REPRODUC
TION
, COPYING, OR
USE OF THIS DRAWING
WITHOU
T THE WRITTEN
CON
SENT OF SW
YGERT &
ASSOCIATES IS PROHIBITED
AND ANY INFRINGEMENT WILL
BE SUBJECT TO LEGAL ACTION
.
BID
DOCU
MENT
S
9' - 11"
8' - 5"
8' - 4"
8' - 11 1/2"8' - 11 1/2"
9' - 11"
OPEN TO ABOVE
OPEN TO ABOVE
OPEN TO ABOVE
EXPOSED STRUCTURE
EXPOSEDSTRUCTURE
EXPOSED STRUCTURE
EXPOSEDSTRUCTURE
EXPOSED STRUCTURE
8' - 2"
8' - 0" 8' - 5 3/4"
8' - 0"
OPEN TO ABOVE
NO ACCESSTO FIELD VERIFY
EXPOSED STRUCTURE
13' - 8"
13' - 8"
EXPOSED STRUCTURE
13' - 8"
13' - 8"
13' - 8"
13' - 8"
13' - 8"EXPOSEDSTRUCTURE
13' - 8"
OFFICE012A
CUST.012
STORAGE011
CUST.009
HALLH005
LAUNDRY007
TLT008
ELEC010
STAIRST01
CHASE004
TLT006
LAUNDRY007A
HALLH004
BEDROOM005
MECH003A
PANTRY003B
LIVING003
HALLH002
HALLH001
TRASH002
TRASH002A
VENDING001
HALLH003
ELEVEV01
ELEVEV02
11
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
CONSTRUCTION PHASING LINE.
PHASE B CONSTRUCTION AREA
AREA NOT TO BE DISTURBED BYCONSTRUCTION
PHASE A CONSTRUCTION AREA, LIMITEDSCOPE IN PHASE B, SEE ALL NOTES
DEMOLITION - TO BE NOTED ONDEMO PLANS ONLY
EXISTING TEXTURE CEILING(ASBESTOS)
INSTALL GRID AND 2'X2' ACT CEILING, SEE FINISHSCHEDULE. SEE ELECTRICAL FOR NEW LIGHTS. (EXISTINGAPC WALL ANGLE TO REMAIN, SEE DEMOLITION KEYNOTES.)
PAINT EXISTING METAL PERIMETER SOFFIT ENTIREPERIMETER OF BUILDING.
INSTALL NEW GWB CEILING TO MATCH EXISTING. NEWLIGHTS, SEE ELECTRICAL.
EXISTING GRILL TO BE REMOVED AND GWB BOARD TO BEPATCHED BY OWNERS. G.C. TO PAINT AT EXPOSED AREAS.
OPENING IN CONCRETE ROOF DECK TO BE CUT ANDCAPPED IN PHASE A. PROVIDE SHEET ROCK SOFFIT INPHASE A TO CONCEAL ROOF OPENING. EXISTING CHASEWALL TO REMAIN DURING PHASE A. SEE DETAIL 2/A2.3 FORPHASE A SOFFIT PLAN.
1
2
3
4
5
1. SEE PHASING LEGEND. PHASE B AREA AND ADJACENT WALLS ARE NOT TO BEDISTURBED DURING PHASE A TO PREVENT PHASE B HAZARDOUS MATERIALS FROMBEING DISTURBED. THE BOUNDARY WALL SEPARATING PHASE A AND PHASE B IS NOTTO BE DISTURBED DURING PHASE A.2. CONTACT OWNER UPON DISCOVERY OF ANY ASBESTOS-CONTAINING MATERIALSOR OTHER SUSPECTED HAZARDOUS MATERIALS NOT SHOW TO BE REMOVED ORALTERED WITHIN THE PROJECT SCOPE.3. FIELD VERIFY EXISTING CONDITIONS PRIOR TO COMMENCEMENT OF DEMOLITIONAND NEW WORK. INFORMATION SHOWN IS BASED ON THE EXISTING DRAWINGSPROVIDED BY THE OWNER. GENERAL CONTRACTOR AND SUB-CONTRACTORS ARE TOVERIFY EXISTING CONDITIONS PRIOR TO BID AND PRIOR TO CONSTRUCTION.4. CONTRACTOR SHALL PHOTOGRAPH AND VIDEO ALL SPACES PRIOR TOCOMMENCEMENT OF RENOVATION/NEW WORK TO DOCUMENT PRE-CONSTRUCTIONCONDITIONS. PROVIDE ARCHITECT WITH ELECTRONIC COPIES OF PHOTOGRAPHSAND VIDEO.5. CORE DRILLING IN EXISTING SLAB FOR NEW UTILITY SERVICE IS NOT SHOWN ONTHIS PLAN. SEE MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FOR REQUIREDUTILITY ROUTING.6. SEE MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS FOR ADDITIONAL ITEMSTO REMAIN AND BE PROTECTED THROUGHOUT CONSTRUCTION, INCLUDING DATA ANDPOWER CONDUITS, LIGHTS, PIPES AND DUCTWORK.7. ITEMS TO BE SALVAGED AND REMOVED BY OWNER PRIOR TO DEMOLITION AREIDENTIFIED WITHIN THE SPECIFICATIONS.8. PROTECT EXISTING BUILDING SCOPE NOT INCLUDED INDEMOLITION/CONSTRUCTION SCOPE. REPAIR OR REPLACEMENT DAMAGED AREASNOT IN THIS SCOPE SHALL BE INCLUDED IN THE WORK, WITH NO ADDITIONAL COST TOTHE OWNER.9. ELECTRICAL CONTRACTOR IS TO VERIFY ALL CEILING MOUNTED ELECTRICALDEVICES ARE IN WORKING CONDITION AT COMMENCEMENT OFDEMOLITION/CONSTRUCTION. SEE ELECTRICAL DRAWINGS AND SPECS FOR ALLSCOPE RELATED TO CEILING MOUNTED DEVICES PRIOR TO COMMENCEMENT OFDEMOLITION/CONSTRUCTION.10. SEE ELECTRICAL FOR FULL SCOPE AND COORDINATION OF ALL LIGHTINGDEMOLITION/CONSTRUCTION FOR BASE BID AND ALTERNATE NO. 1.11. ELEVATORS ARE NOT PART OF THE PROJECT SCOPE BUT MAY BE USED DURINGTHE DEMOLITION AND CONSTRUCTION PERIOD. ELEVATORS SHOULD BE PROTECTED,CLEANED AND RETURNED TO THE CONDITION IN WHICH THEY WERE FOUND AT THEEND OF EACH JOB PHASE. SEE SPECIFICATIONS.
INSTALL NEW SOFFIT. SEE MECHANICAL AND DETAIL 6/A3.2 FOR FULLCOORDINATION AND EXTENT OF SCOPE.
REINSTALL EXISTING LIGHT FIXTURE. SEE ELECTRICAL FOR FULLSCOPE AND COORDINATION OF LIGHTINGDEMOLITION/CONSTRUCTION FOR BASE BID AND ALTERNATE NO. 1.
SEE ELECTRICAL DRAWINGS FOR FULL SCOPE AND COORDINATIONOF ALL LIGTHING DEMOLLITION/CONSTRUCTION FOR BASE BID ANDALTERNATE NO. 1.
NEW FAN COIL UNIT. SEE MECHANICAL.
EXISTING LIGHT TO REMAIN. G.C. TO VERIFY EXISTING LOCATIONSARE NOT IN CONFLICT WITH NEW MECHANICAL SYSTEMS PRIOR TOEND OF ASBESTOS ABATEMENT DEMOLITION, TYP. G.C. TORELOCATE AND COORDINATE NEW LOCATION WITH ARCHITECT INFIELD, IF IN CONFLICT WITH NEW MECHANICAL. SEE ELECTRICAL FORFULL SCOPE AND COORDINATION OF LIGHTINGDEMOLITION/CONSTRUCTION FOR BASE BID AND ALTERNATE NO. 1.
NEW METAL PIPE ENCLOSURE. FIELD VERIFY AND COORDINATEDIMENSIONS AND LAYOUT WITH MECHANICAL PIPING ANDELECTRICAL. SEE DETAIL 8/A3.2.
APPLY SPRAY TEXTURE FINISH TO MATCH EXISTING ADJACENTCEILING WHERE EXISTING METAL SOFFIT HAS BEEN DECREASED INSIZE AND UNDERSIDE OF DECK /CEILING HAS BEEN EXPOSED. SEESPEC.
INSTALL NEW STEEL SUPPORT ANGLE AND NEW METAL SOFFIT. SEEDETAIL 7/A3.2 FOR FULL COORDINATION AND EXTENT OF SCOPE.
SELECTIVE REMOVAL OF APC CEILING TILE ONLY INSTALLED INPHASE A TO ALLOW FOR REQUIRED MECHANICAL, ELECTRICAL ANDPLUMBING CONNECTIONS AND/OR REMOVAL OF PIPING. SEEMECHANICAL, ELECRICAL, AND PLUMBING. PROTECT EXISTINGCEILING TILE, GRID AND AND ADJACENT CEILING MATERIALS ANDREINSTALL CEILING TILE AFTER REMOVAL OF PHASE B PLUMBINGSCOPE IS COMPLETE.
A
B
C
D
E
F
G
H
J
1. SEE PHASING LEGEND. PHASE B AREA AND ADJACENT WALLS ARE NOT TO BEDISTURBED DURING PHASE A TO PREVENT PHASE B HAZARDOUS MATERIALS FROMBEING DISTURBED. THE BOUNDARY WALL SEPARATING PHASE A AND PHASE B IS NOTTO BE DISTURBED DURING PHASE A.2. CONTACT OWNER UPON DISCOVERY OF ANY ASBESTOS-CONTAINING MATERIALSOR OTHER SUSPECTED HAZARDOUS MATERIALS NOT SHOW TO BE REMOVED ORALTERED WITHIN THE PROJECT SCOPE.3. FIELD VERIFY EXISTING CONDITIONS PRIOR TO COMMENCEMENT OF DEMOLITIONAND NEW WORK. INFORMATION SHOWN IS BASED ON THE EXISTING DRAWINGSPROVIDED BY THE OWNER. GENERAL CONTRACTOR AND SUB-CONTRACTORS ARE TOVERIFY EXISTING CONDITIONS PRIOR TO BID AND PRIOR TO CONSTRUCTION.4. CONTRACTOR SHALL PHOTOGRAPH AND VIDEO ALL SPACES PRIOR TOCOMMENCEMENT OF RENOVATION/NEW WORK TO DOCUMENT PRE-CONSTRUCTIONCONDITIONS. PROVIDE ARCHITECT WITH ELECTRONIC COPIES OF PHOTOGRAPHSAND VIDEO.5. CORE DRILLING IN EXISTING SLAB FOR NEW UTILITY SERVICE IS NOT SHOWN ONTHIS PLAN. SEE MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FOR REQUIREDUTILITY ROUTING.6. SEE MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS FOR ADDITIONAL ITEMSTO REMAIN AND BE PROTECTED THROUGHOUT CONSTRUCTION, INCLUDING DATA ANDPOWER CONDUITS, LIGHTS, PIPES AND DUCTWORK.7. ITEMS TO BE SALVAGED AND REMOVED BY OWNER PRIOR TO DEMOLITION AREIDENTIFIED WITHIN THE SPECIFICATIONS.8. PROTECT EXISTING BUILDING SCOPE NOT INCLUDED INDEMOLITION/CONSTRUCTION SCOPE. REPAIR OR REPLACEMENT DAMAGED AREASNOT IN THIS SCOPE SHALL BE INCLUDED IN THE WORK, WITH NO ADDITIONAL COST TOTHE OWNER.9. ELECTRICAL CONTRACTOR IS TO VERIFY ALL CEILING MOUNTED ELECTRICALDEVICES ARE IN WORKING CONDITION AT COMMENCEMENT OFDEMOLITION/CONSTRUCTION. SEE ELECTRICAL DRAWINGS AND SPECS FOR ALLSCOPE RELATED TO CEILING MOUNTED DEVICES PRIOR TO COMMENCEMENT OFDEMOLITION/CONSTRUCTION.10. SEE ELECTRICAL FOR FULL SCOPE AND COORDINATION OF LIGHTINGDEMOLITION/CONSTRUCTION FOR BASE BID AND ALTERNATE NO. 1.11. ELEVATORS ARE NOT PART OF THE PROJECT SCOPE BUT MAY BE USED DURINGTHE DEMOLITION AND CONSTRUCTION PERIOD. ELEVATORS SHOULD BE PROTECTED,CLEANED AND RETURNED TO THE CONDITION IN WHICH THEY WERE FOUND AT THEEND OF EACH JOB PHASE. SEE SPECIFICATIONS.
N
PHASE A WORK - NOTE TO CONTRACTORS:
1. NO PENETRATIONS OR ATTACHMENTS TO THE EXISTING GYPSUM BOARD PARTITIONS WILL BE ALLOWED ONCE THEASBESTOS ABATEMENT HAS BEEN COMPLETED BY THE ABATEMENT CONTRACTOR.
2. THE CONTRACTOR SHALL NOT COME IN CONTACT WITH THE GYPSUM BOARD MATERIAL THAT IS TO REMAIN IN PLACE AFTERTHE PARTIAL ABATEMENT OF ASBESTOS FROM THE CORRIDOR PARTITIONS ON THE EXISTING FLOORS 2 THRU 18 AND OTHERPARTITIONS ON THE BASEMENT AND GROUND LEVELS. CONTAMINATION OF THESE SPACES CAUSED BY DAMAGE TO THEGYPSUM BOARD MATERIAL SHALL BE CLEANED UP AT THE CONTRACTOR'S EXPENSE, INCLUDING BUT NOT LIMITED TO, COSTSASSOCIATED WITH CLEARING THESE SPACES FOR RE-ACCESS, I.E. AIR SAMPLING.
PHASE B WORK - NOTE TO CONTRACTORS:
1. DURING THE PROCESS OF INSTALLING HANGERS, SOFFITS, FAN COILS, METAL PAN COVERS, NEW PARTITIONS OR ANY OTHERMATERIAL OR EQUIPMENT AT THE CEILINGS OF THE EXISTING RESIDENT ROOMS ON FLOORS 2 THRU 18, THE CONTRACTORSHALL NOT COME IN CONTACT WITH THE SPRAY APPLIED TEXTURED CEILING MATERIAL THAT IS TO REMAIN IN PLACE AFTER THEPARTIAL ABATEMENT OF ASBESTOS FROM THE CEILINGS. CONTAMINATION OF THESE SPACES CAUSED BY DAMAGE TO THECEILING MATERIAL SHALL BE CLEANED UP AT THE CONTRACTOR'S EXPENSE, INCLUDING BUT NOT LIMITED TO, COSTSASSOCIATED WITH CLEARING THESE SPACES FOR RE-ACCESS, I.E. AIR SAMPLING.
2. DURING THE PROCESS OF INSTALLING UL RATED RACEWAYS AT CORRIDOR WALL PENETRATION, INSTALLATION OF NEWPARTITIONS, THE CONTRACTOR SHALL NOT DISTURB THE EXISTING GYPSUM BOARD IN ANY FASHION. NO PENETRATIONS WILLBE ALLOWED ONCE THE ASBESTOS ABATEMENT HAS BEEN COMPLETED BY THE ABATEMENT CONTRACTOR.
REFERENCED ON: 1/4" = 1'-0"A2.011 GROUND LEVEL REFLECTED CEILING PLAN
LEGEND
PHASE A - TYPICAL RCP KEYNOTESPHASE A - GENERAL RCP NOTES
PHASE B - TYPICAL RCP KEYNOTESPHASE B - GENERAL RCP NOTES
A2.01
GROU
ND LE
VEL R
EFLE
CTED
CEILI
NG P
LAN
RMB
SAL
1
ED
C
2 3 4
BA
1 2 3 4
UNIV
ERSI
TY O
F SO
UTH
CARO
LINA
MECH
ANIC
AL R
ENOV
ATIO
NSSO
UTH
TOW
ER
5 6 7
E
SHEET:
SHEE
T TI
TLE:
DRAW
N BY
:
D
REV.
DRAW
ING:
DESC
RIPT
ION
03/15
/12DA
TE:
PROJ
ECT
TITL
E:
C
CHEC
KED
BY:
DATE
ORIG
. BY
DRAW
N BY
5 6
Facsimile: (803) 791-0830
B
SEAL
SEAL
Swyg
ert &
Ass
ocia
tes
C O
N S
U L
T I
N G
E
N G
I N
E E
R S
Post Office Box 11686
DBA Swygert & Assoc. Ltd.
A
Telephone: (803) 791-9300
Columbia, S.C. 29211
mail@
swygert-associates.com
7
STAT
E PR
OJEC
T NU
MBER
H27
-608
2-NA
THIS DRAWING AND THE
DESIGN THEREON ARE THE
PROPERTY OF SW
YGERT &
ASSOCIATES, LTD. THE
REPRODUC
TION
, COPYING, OR
USE OF THIS DRAWING
WITHOU
T THE WRITTEN
CON
SENT OF SW
YGERT &
ASSOCIATES IS PROHIBITED
AND ANY INFRINGEMENT WILL
BE SUBJECT TO LEGAL ACTION
.
BID
DOCU
MENT
S
14'-5 1/2"EXPOSED
STRUCTURE
14' 5 1/2"EXPOSED
STRUCTURE
OPEN TO ABOVE
OPEN TO ABOVE
OPEN TO ABOVE
7'-1" CEILINGHEIGHT INELEVATOR CAB
11' - 0 3/4"
12' - 5 1/4"
11' - 11 1/4"
11' - 11 1/4"8' - 2"
8' - 8"
8' - 0"8' - 0"
EXP STRUCTURE
STUDY107
LOBBY101
VESTIBULEV101
HALLH101
VESTIBULEV102
LOBBY101
OFFICE102
RA BEDROOM103A
TLT103B
CLST103CRA LIVING
103RA KITCHEN
103D
MEN105
CHASE104A
ELEC106
CUST104
2 2 2 2 2
2
2
2
222
2
2
1
1 1
1
1
1
1
1
1
1
1
1
1
3
8' - 2"
11' - 11 1/4"
8' - 5 1/2"
12' - 0"
8' - 0"
11' - 11 1/4"
11' - 11 1/2"
8' - 2"8' - 5 1/2"
11' - 11"
11' - 11" 11' - 11"
7' - 11 1/2"
11' - 11 1/2"
11' - 11 1/4"
11' - 11 1/4"
J
J
J
J
J
3
CONSTRUCTION PHASING LINE.
PHASE B CONSTRUCTION AREA
AREA NOT TO BE DISTURBED BYCONSTRUCTION
PHASE A CONSTRUCTION AREA, LIMITEDSCOPE IN PHASE B, SEE ALL NOTES
DEMOLITION - TO BE NOTED ONDEMO PLANS ONLY
EXISTING TEXTURE CEILING(ASBESTOS)
1. SEE PHASING LEGEND. PHASE B AREA AND ADJACENT WALLS ARE NOT TO BEDISTURBED DURING PHASE A TO PREVENT PHASE B HAZARDOUS MATERIALS FROMBEING DISTURBED. THE BOUNDARY WALL SEPARATING PHASE A AND PHASE B IS NOTTO BE DISTURBED DURING PHASE A.2. CONTACT OWNER UPON DISCOVERY OF ANY ASBESTOS-CONTAINING MATERIALSOR OTHER SUSPECTED HAZARDOUS MATERIALS NOT SHOW TO BE REMOVED ORALTERED WITHIN THE PROJECT SCOPE.3. FIELD VERIFY EXISTING CONDITIONS PRIOR TO COMMENCEMENT OF DEMOLITIONAND NEW WORK. INFORMATION SHOWN IS BASED ON THE EXISTING DRAWINGSPROVIDED BY THE OWNER. GENERAL CONTRACTOR AND SUB-CONTRACTORS ARE TOVERIFY EXISTING CONDITIONS PRIOR TO BID AND PRIOR TO CONSTRUCTION.4. CONTRACTOR SHALL PHOTOGRAPH AND VIDEO ALL SPACES PRIOR TOCOMMENCEMENT OF RENOVATION/NEW WORK TO DOCUMENT PRE-CONSTRUCTIONCONDITIONS. PROVIDE ARCHITECT WITH ELECTRONIC COPIES OF PHOTOGRAPHSAND VIDEO.5. CORE DRILLING IN EXISTING SLAB FOR NEW UTILITY SERVICE IS NOT SHOWN ONTHIS PLAN. SEE MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FOR REQUIREDUTILITY ROUTING.6. SEE MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS FOR ADDITIONAL ITEMSTO REMAIN AND BE PROTECTED THROUGHOUT CONSTRUCTION, INCLUDING DATA ANDPOWER CONDUITS, LIGHTS, PIPES AND DUCTWORK.7. ITEMS TO BE SALVAGED AND REMOVED BY OWNER PRIOR TO DEMOLITION AREIDENTIFIED WITHIN THE SPECIFICATIONS.8. PROTECT EXISTING BUILDING SCOPE NOT INCLUDED INDEMOLITION/CONSTRUCTION SCOPE. REPAIR OR REPLACEMENT DAMAGED AREASNOT IN THIS SCOPE SHALL BE INCLUDED IN THE WORK, WITH NO ADDITIONAL COST TOTHE OWNER.9. ELECTRICAL CONTRACTOR IS TO VERIFY ALL CEILING MOUNTED ELECTRICALDEVICES ARE IN WORKING CONDITION AT COMMENCEMENT OFDEMOLITION/CONSTRUCTION. SEE ELECTRICAL DRAWINGS AND SPECS FOR ALLSCOPE RELATED TO CEILING MOUNTED DEVICES PRIOR TO COMMENCEMENT OFDEMOLITION/CONSTRUCTION.10. SEE ELECTRICAL FOR FULL SCOPE AND COORDINATION OF ALL LIGHTINGDEMOLITION/CONSTRUCTION FOR BASE BID AND ALTERNATE NO. 1.11. ELEVATORS ARE NOT PART OF THE PROJECT SCOPE BUT MAY BE USED DURINGTHE DEMOLITION AND CONSTRUCTION PERIOD. ELEVATORS SHOULD BE PROTECTED,CLEANED AND RETURNED TO THE CONDITION IN WHICH THEY WERE FOUND AT THEEND OF EACH JOB PHASE. SEE SPECIFICATIONS.
1. SEE PHASING LEGEND. PHASE B AREA AND ADJACENT WALLS ARE NOT TO BEDISTURBED DURING PHASE A TO PREVENT PHASE B HAZARDOUS MATERIALS FROMBEING DISTURBED. THE BOUNDARY WALL SEPARATING PHASE A AND PHASE B IS NOTTO BE DISTURBED DURING PHASE A.2. CONTACT OWNER UPON DISCOVERY OF ANY ASBESTOS-CONTAINING MATERIALSOR OTHER SUSPECTED HAZARDOUS MATERIALS NOT SHOW TO BE REMOVED ORALTERED WITHIN THE PROJECT SCOPE.3. FIELD VERIFY EXISTING CONDITIONS PRIOR TO COMMENCEMENT OF DEMOLITIONAND NEW WORK. INFORMATION SHOWN IS BASED ON THE EXISTING DRAWINGSPROVIDED BY THE OWNER. GENERAL CONTRACTOR AND SUB-CONTRACTORS ARE TOVERIFY EXISTING CONDITIONS PRIOR TO BID AND PRIOR TO CONSTRUCTION.4. CONTRACTOR SHALL PHOTOGRAPH AND VIDEO ALL SPACES PRIOR TOCOMMENCEMENT OF RENOVATION/NEW WORK TO DOCUMENT PRE-CONSTRUCTIONCONDITIONS. PROVIDE ARCHITECT WITH ELECTRONIC COPIES OF PHOTOGRAPHSAND VIDEO.5. CORE DRILLING IN EXISTING SLAB FOR NEW UTILITY SERVICE IS NOT SHOWN ONTHIS PLAN. SEE MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FOR REQUIREDUTILITY ROUTING.6. SEE MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS FOR ADDITIONAL ITEMSTO REMAIN AND BE PROTECTED THROUGHOUT CONSTRUCTION, INCLUDING DATA ANDPOWER CONDUITS, LIGHTS, PIPES AND DUCTWORK.7. ITEMS TO BE SALVAGED AND REMOVED BY OWNER PRIOR TO DEMOLITION AREIDENTIFIED WITHIN THE SPECIFICATIONS.8. PROTECT EXISTING BUILDING SCOPE NOT INCLUDED INDEMOLITION/CONSTRUCTION SCOPE. REPAIR OR REPLACEMENT DAMAGED AREASNOT IN THIS SCOPE SHALL BE INCLUDED IN THE WORK, WITH NO ADDITIONAL COST TOTHE OWNER.9. ELECTRICAL CONTRACTOR IS TO VERIFY ALL CEILING MOUNTED ELECTRICALDEVICES ARE IN WORKING CONDITION AT COMMENCEMENT OFDEMOLITION/CONSTRUCTION. SEE ELECTRICAL DRAWINGS AND SPECS FOR ALLSCOPE RELATED TO CEILING MOUNTED DEVICES PRIOR TO COMMENCEMENT OFDEMOLITION/CONSTRUCTION.10. SEE ELECTRICAL FOR FULL SCOPE AND COORDINATION OF LIGHTINGDEMOLITION/CONSTRUCTION FOR BASE BID AND ALTERNATE NO. 1.11. ELEVATORS ARE NOT PART OF THE PROJECT SCOPE BUT MAY BE USED DURINGTHE DEMOLITION AND CONSTRUCTION PERIOD. ELEVATORS SHOULD BE PROTECTED,CLEANED AND RETURNED TO THE CONDITION IN WHICH THEY WERE FOUND AT THEEND OF EACH JOB PHASE. SEE SPECIFICATIONS.
INSTALL NEW SOFFIT. SEE MECHANICAL AND DETAIL 6/A3.2 FOR FULLCOORDINATION AND EXTENT OF SCOPE.
REINSTALL EXISTING LIGHT FIXTURE. SEE ELECTRICAL FOR FULLSCOPE AND COORDINATION OF LIGHTINGDEMOLITION/CONSTRUCTION FOR BASE BID AND ALTERNATE NO. 1.
SEE ELECTRICAL DRAWINGS FOR FULL SCOPE AND COORDINATIONOF ALL LIGTHING DEMOLLITION/CONSTRUCTION FOR BASE BID ANDALTERNATE NO. 1.
NEW FAN COIL UNIT. SEE MECHANICAL.
EXISTING LIGHT TO REMAIN. G.C. TO VERIFY EXISTING LOCATIONSARE NOT IN CONFLICT WITH NEW MECHANICAL SYSTEMS PRIOR TOEND OF ASBESTOS ABATEMENT DEMOLITION, TYP. G.C. TORELOCATE AND COORDINATE NEW LOCATION WITH ARCHITECT INFIELD, IF IN CONFLICT WITH NEW MECHANICAL. SEE ELECTRICAL FORFULL SCOPE AND COORDINATION OF LIGHTINGDEMOLITION/CONSTRUCTION FOR BASE BID AND ALTERNATE NO. 1.
NEW METAL PIPE ENCLOSURE. FIELD VERIFY AND COORDINATEDIMENSIONS AND LAYOUT WITH MECHANICAL PIPING ANDELECTRICAL. SEE DETAIL 8/A3.2.
APPLY SPRAY TEXTURE FINISH TO MATCH EXISTING ADJACENTCEILING WHERE EXISTING METAL SOFFIT HAS BEEN DECREASED INSIZE AND UNDERSIDE OF DECK /CEILING HAS BEEN EXPOSED. SEESPEC.
INSTALL NEW STEEL SUPPORT ANGLE AND NEW METAL SOFFIT. SEEDETAIL 7/A3.2 FOR FULL COORDINATION AND EXTENT OF SCOPE.
SELECTIVE REMOVAL OF APC CEILING TILE ONLY INSTALLED INPHASE A TO ALLOW FOR REQUIRED MECHANICAL, ELECTRICAL ANDPLUMBING CONNECTIONS AND/OR REMOVAL OF PIPING. SEEMECHANICAL, ELECRICAL, AND PLUMBING. PROTECT EXISTINGCEILING TILE, GRID AND AND ADJACENT CEILING MATERIALS ANDREINSTALL CEILING TILE AFTER REMOVAL OF PHASE B PLUMBINGSCOPE IS COMPLETE.
A
B
C
D
E
F
G
H
J
INSTALL GRID AND 2'X2' ACT CEILING, SEE FINISHSCHEDULE. SEE ELECTRICAL FOR NEW LIGHTS. (EXISTINGAPC WALL ANGLE TO REMAIN, SEE DEMOLITION KEYNOTES.)
PAINT EXISTING METAL PERIMETER SOFFIT ENTIREPERIMETER OF BUILDING.
INSTALL NEW GWB CEILING TO MATCH EXISTING. NEWLIGHTS, SEE ELECTRICAL.
EXISTING GRILL TO BE REMOVED AND GWB BOARD TO BEPATCHED BY OWNERS. G.C. TO PAINT AT EXPOSED AREAS.
OPENING IN CONCRETE ROOF DECK TO BE CUT ANDCAPPED IN PHASE A. PROVIDE SHEET ROCK SOFFIT INPHASE A TO CONCEAL ROOF OPENING. EXISTING CHASEWALL TO REMAIN DURING PHASE A. SEE DETAIL 2/A2.3 FORPHASE A SOFFIT PLAN.
1
2
3
4
5
N
PHASE B WORK - NOTE TO CONTRACTORS:
1. DURING THE PROCESS OF INSTALLING HANGERS, SOFFITS, FAN COILS, METAL PAN COVERS, NEW PARTITIONS OR ANY OTHERMATERIAL OR EQUIPMENT AT THE CEILINGS OF THE EXISTING RESIDENT ROOMS ON FLOORS 2 THRU 18, THE CONTRACTORSHALL NOT COME IN CONTACT WITH THE SPRAY APPLIED TEXTURED CEILING MATERIAL THAT IS TO REMAIN IN PLACE AFTER THEPARTIAL ABATEMENT OF ASBESTOS FROM THE CEILINGS. CONTAMINATION OF THESE SPACES CAUSED BY DAMAGE TO THECEILING MATERIAL SHALL BE CLEANED UP AT THE CONTRACTOR'S EXPENSE, INCLUDING BUT NOT LIMITED TO, COSTSASSOCIATED WITH CLEARING THESE SPACES FOR RE-ACCESS, I.E. AIR SAMPLING.
2. DURING THE PROCESS OF INSTALLING UL RATED RACEWAYS AT CORRIDOR WALL PENETRATION, INSTALLATION OF NEWPARTITIONS, THE CONTRACTOR SHALL NOT DISTURB THE EXISTING GYPSUM BOARD IN ANY FASHION. NO PENETRATIONS WILLBE ALLOWED ONCE THE ASBESTOS ABATEMENT HAS BEEN COMPLETED BY THE ABATEMENT CONTRACTOR.
PHASE A WORK - NOTE TO CONTRACTORS:
1. NO PENETRATIONS OR ATTACHMENTS TO THE EXISTING GYPSUM BOARD PARTITIONS WILL BE ALLOWED ONCE THEASBESTOS ABATEMENT HAS BEEN COMPLETED BY THE ABATEMENT CONTRACTOR.
2. THE CONTRACTOR SHALL NOT COME IN CONTACT WITH THE GYPSUM BOARD MATERIAL THAT IS TO REMAIN IN PLACE AFTERTHE PARTIAL ABATEMENT OF ASBESTOS FROM THE CORRIDOR PARTITIONS ON THE EXISTING FLOORS 2 THRU 18 AND OTHERPARTITIONS ON THE BASEMENT AND GROUND LEVELS. CONTAMINATION OF THESE SPACES CAUSED BY DAMAGE TO THEGYPSUM BOARD MATERIAL SHALL BE CLEANED UP AT THE CONTRACTOR'S EXPENSE, INCLUDING BUT NOT LIMITED TO, COSTSASSOCIATED WITH CLEARING THESE SPACES FOR RE-ACCESS, I.E. AIR SAMPLING.
REFERENCED ON: 1/4" = 1'-0"A2.11 FIRST FLOOR REFLECTED CEILING PLAN
LEGEND
PHASE A - GENERAL RCP NOTES
PHASE B - GENERAL RCP NOTES PHASE B - TYPICAL RCP KEYNOTES
PHASE A - TYPICAL RCP KEYNOTES
A2.1
FIRS
T FL
OOR
REFL
ECTE
D CE
ILING
PLA
N
RMB
SAL
1
ED
C
2 3 4
BA
1 2 3 4
UNIV
ERSI
TY O
F SO
UTH
CARO
LINA
MECH
ANIC
AL R
ENOV
ATIO
NSSO
UTH
TOW
ER
5 6 7
E
SHEET:
SHEE
T TI
TLE:
DRAW
N BY
:
D
REV.
DRAW
ING:
DESC
RIPT
ION
03/15
/12DA
TE:
PROJ
ECT
TITL
E:
C
CHEC
KED
BY:
DATE
ORIG
. BY
DRAW
N BY
5 6
Facsimile: (803) 791-0830
B
SEAL
SEAL
Swyg
ert &
Ass
ocia
tes
C O
N S
U L
T I
N G
E
N G
I N
E E
R S
Post Office Box 11686
DBA Swygert & Assoc. Ltd.
A
Telephone: (803) 791-9300
Columbia, S.C. 29211
mail@
swygert-associates.com
7
STAT
E PR
OJEC
T NU
MBER
H27
-608
2-NA
THIS DRAWING AND THE
DESIGN THEREON ARE THE
PROPERTY OF SW
YGERT &
ASSOCIATES, LTD. THE
REPRODUC
TION
, COPYING, OR
USE OF THIS DRAWING
WITHOU
T THE WRITTEN
CON
SENT OF SW
YGERT &
ASSOCIATES IS PROHIBITED
AND ANY INFRINGEMENT WILL
BE SUBJECT TO LEGAL ACTION
.
BID
DOCU
MENT
S
8' - 6"
8' - 6" 8' - 6" 8' - 6" 8' - 6"
8' - 6"
8' - 6"8' - 6"8' - 6"8' - 6"8' - 6"
8' - 6"
8' - 6"
7' - 2 5/8"
7' - 2 5/8"
7' - 2 5/8"
7' - 4"
8'-6"EXPOSED
STRUCTURE
8'-6"EXPOSED
STRUCTURE
OPEN TO ABOVE
OPEN TO ABOVE
OPEN TO ABOVE
SLOPED SLOPED
SLOPED SLOPED
EXPOSEDSTRUCTURE
EXPOSEDSTRUCTURE
1
1
1
7' - 2 5/8"7' - 2 5/8"
7' - 2
5/8"
7' - 2 5/8" 7' - 2 5/8" 7' - 2 5/8" 7' - 2 5/8" 7' - 2 5/8"
7' - 2
5/8"
7' - 2 5/8"
6
A3.2
AA
H
H
H
H
A A A A A
H
H
H
AAABB B BB
BB B BB
CC C CC
CC C CC
EE E E E
EEEEE
E
E
RESIDENTFL#08 RESIDENT
FL#09RESIDENT
FL#10RESIDENT
FL#11RESIDENT
FL#12
COMMUNITYFL#13
CUSTFL#14
WOMENFL#15
ELECFL#16
RESIDENTFL#00
RESIDENTFL#01
RESIDENTFL#02
RESIDENTFL#03
RESIDENTFL#04
RESIDENTFL#05
RESIDENTFL#06
RESIDENTFL#07
HALLHFL#03
HALLHFL#01
HALLHLF#02
CHASEFL#17
F.V.
2' - 0
1/4"
1' - 4"
F.V.
1' - 9
3/4"
ALIGN
7' - 2 5/8" 7' - 2 5/8"
ALIGN ALIGN ALIGN
ALIGN ALIGN ALIGN ALIGN ALIGN
ALIGN
F.V.12' - 9 1/2"
F.V.12' - 7 1/4"
F.V.12' - 7 1/8"
F.V.12' - 7 1/8"
F.V.12' - 9 5/8"
F.V.
16' -
3 3/4"
F.V.
17' -
8 3/8"
F.V.
12' -
3 7/8"
F.V.
16' -
1 3/4"
F.V.12' - 9 1/2"
F.V.12' - 7 1/4"
F.V.12' - 7 1/8"
F.V.12' - 7 1/8"
F.V.12' - 9 5/8"
F.V.
16' -
1 3/4"
F.V.
17' -
9 7/8"
F.V.
16' -
3 3/4"
7' - 0"
MIN.8"
MIN.4"
MIN.4"
MIN.8"
MIN.4"
MIN.8"
8' - 1
"
8' - 1
"
8' - 1
"
8' - 1
"
8' - 1"
8' - 1"
8' - 1"
8' - 1"
8' - 1
"
8' - 1
"
8' - 1
"
8' - 1"
8' - 1"
7' - 6"7' - 6"
7' - 6"7' - 6"7' - 6"7' - 6"7' - 6"
7' - 6"
7' - 6"
7' - 6"
7' - 6" 7' - 6" 7' - 6"7' - 6"
7' - 6"
DDDDD
D
D
D
D D D D
D
FFFFF
F
F
F
F F F
F
F
8
A3.2
G
8' - 1"
1' - 4
"4'
- 5"
7
A3.2
5' - 0"
8' - 2 7/8"
A3.11
J
J
J
C
C
C
C
INSTALL GRID AND 2'X2' ACT CEILING, SEE FINISHSCHEDULE. SEE ELECTRICAL FOR NEW LIGHTS. (EXISTINGAPC WALL ANGLE TO REMAIN, SEE DEMOLITION KEYNOTES.)
PAINT EXISTING METAL PERIMETER SOFFIT ENTIREPERIMETER OF BUILDING.
INSTALL NEW GWB CEILING TO MATCH EXISTING. NEWLIGHTS, SEE ELECTRICAL.
EXISTING GRILL TO BE REMOVED AND GWB BOARD TO BEPATCHED BY OWNERS. G.C. TO PAINT AT EXPOSED AREAS.
OPENING IN CONCRETE ROOF DECK TO BE CUT ANDCAPPED IN PHASE A. PROVIDE SHEET ROCK SOFFIT INPHASE A TO CONCEAL ROOF OPENING. EXISTING CHASEWALL TO REMAIN DURING PHASE A. SEE DETAIL 2/A2.3 FORPHASE A SOFFIT PLAN.
1
2
3
4
5
CONSTRUCTION PHASING LINE.
PHASE B CONSTRUCTION AREA
AREA NOT TO BE DISTURBED BYCONSTRUCTION
PHASE A CONSTRUCTION AREA, LIMITEDSCOPE IN PHASE B, SEE ALL NOTES
DEMOLITION - TO BE NOTED ONDEMO PLANS ONLY
EXISTING TEXTURE CEILING(ASBESTOS)
INSTALL NEW SOFFIT. SEE MECHANICAL AND DETAIL 6/A3.2 FOR FULLCOORDINATION AND EXTENT OF SCOPE.
REINSTALL EXISTING LIGHT FIXTURE. SEE ELECTRICAL FOR FULLSCOPE AND COORDINATION OF LIGHTINGDEMOLITION/CONSTRUCTION FOR BASE BID AND ALTERNATE NO. 1.
SEE ELECTRICAL DRAWINGS FOR FULL SCOPE AND COORDINATIONOF ALL LIGTHING DEMOLLITION/CONSTRUCTION FOR BASE BID ANDALTERNATE NO. 1.
NEW FAN COIL UNIT. SEE MECHANICAL.
EXISTING LIGHT TO REMAIN. G.C. TO VERIFY EXISTING LOCATIONSARE NOT IN CONFLICT WITH NEW MECHANICAL SYSTEMS PRIOR TOEND OF ASBESTOS ABATEMENT DEMOLITION, TYP. G.C. TORELOCATE AND COORDINATE NEW LOCATION WITH ARCHITECT INFIELD, IF IN CONFLICT WITH NEW MECHANICAL. SEE ELECTRICAL FORFULL SCOPE AND COORDINATION OF LIGHTINGDEMOLITION/CONSTRUCTION FOR BASE BID AND ALTERNATE NO. 1.
NEW METAL PIPE ENCLOSURE. FIELD VERIFY AND COORDINATEDIMENSIONS AND LAYOUT WITH MECHANICAL PIPING ANDELECTRICAL. SEE DETAIL 8/A3.2.
APPLY SPRAY TEXTURE FINISH TO MATCH EXISTING ADJACENTCEILING WHERE EXISTING METAL SOFFIT HAS BEEN DECREASED INSIZE AND UNDERSIDE OF DECK /CEILING HAS BEEN EXPOSED. SEESPEC.
INSTALL NEW STEEL SUPPORT ANGLE AND NEW METAL SOFFIT. SEEDETAIL 7/A3.2 FOR FULL COORDINATION AND EXTENT OF SCOPE.
SELECTIVE REMOVAL OF APC CEILING TILE ONLY INSTALLED INPHASE A TO ALLOW FOR REQUIRED MECHANICAL, ELECTRICAL ANDPLUMBING CONNECTIONS AND/OR REMOVAL OF PIPING. SEEMECHANICAL, ELECRICAL, AND PLUMBING. PROTECT EXISTINGCEILING TILE, GRID AND AND ADJACENT CEILING MATERIALS ANDREINSTALL CEILING TILE AFTER REMOVAL OF PHASE B PLUMBINGSCOPE IS COMPLETE.
A
B
C
D
E
F
G
H
J
1. SEE PHASING LEGEND. PHASE B AREA AND ADJACENT WALLS ARE NOT TO BEDISTURBED DURING PHASE A TO PREVENT PHASE B HAZARDOUS MATERIALS FROMBEING DISTURBED. THE BOUNDARY WALL SEPARATING PHASE A AND PHASE B IS NOTTO BE DISTURBED DURING PHASE A.2. CONTACT OWNER UPON DISCOVERY OF ANY ASBESTOS-CONTAINING MATERIALSOR OTHER SUSPECTED HAZARDOUS MATERIALS NOT SHOW TO BE REMOVED ORALTERED WITHIN THE PROJECT SCOPE.3. FIELD VERIFY EXISTING CONDITIONS PRIOR TO COMMENCEMENT OF DEMOLITIONAND NEW WORK. INFORMATION SHOWN IS BASED ON THE EXISTING DRAWINGSPROVIDED BY THE OWNER. GENERAL CONTRACTOR AND SUB-CONTRACTORS ARE TOVERIFY EXISTING CONDITIONS PRIOR TO BID AND PRIOR TO CONSTRUCTION.4. CONTRACTOR SHALL PHOTOGRAPH AND VIDEO ALL SPACES PRIOR TOCOMMENCEMENT OF RENOVATION/NEW WORK TO DOCUMENT PRE-CONSTRUCTIONCONDITIONS. PROVIDE ARCHITECT WITH ELECTRONIC COPIES OF PHOTOGRAPHSAND VIDEO.5. CORE DRILLING IN EXISTING SLAB FOR NEW UTILITY SERVICE IS NOT SHOWN ONTHIS PLAN. SEE MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FOR REQUIREDUTILITY ROUTING.6. SEE MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS FOR ADDITIONAL ITEMSTO REMAIN AND BE PROTECTED THROUGHOUT CONSTRUCTION, INCLUDING DATA ANDPOWER CONDUITS, LIGHTS, PIPES AND DUCTWORK.7. ITEMS TO BE SALVAGED AND REMOVED BY OWNER PRIOR TO DEMOLITION AREIDENTIFIED WITHIN THE SPECIFICATIONS.8. PROTECT EXISTING BUILDING SCOPE NOT INCLUDED INDEMOLITION/CONSTRUCTION SCOPE. REPAIR OR REPLACEMENT DAMAGED AREASNOT IN THIS SCOPE SHALL BE INCLUDED IN THE WORK, WITH NO ADDITIONAL COST TOTHE OWNER.9. ELECTRICAL CONTRACTOR IS TO VERIFY ALL CEILING MOUNTED ELECTRICALDEVICES ARE IN WORKING CONDITION AT COMMENCEMENT OFDEMOLITION/CONSTRUCTION. SEE ELECTRICAL DRAWINGS AND SPECS FOR ALLSCOPE RELATED TO CEILING MOUNTED DEVICES PRIOR TO COMMENCEMENT OFDEMOLITION/CONSTRUCTION.10. SEE ELECTRICAL FOR FULL SCOPE AND COORDINATION OF LIGHTINGDEMOLITION/CONSTRUCTION FOR BASE BID AND ALTERNATE NO. 1.11. ELEVATORS ARE NOT PART OF THE PROJECT SCOPE BUT MAY BE USED DURINGTHE DEMOLITION AND CONSTRUCTION PERIOD. ELEVATORS SHOULD BE PROTECTED,CLEANED AND RETURNED TO THE CONDITION IN WHICH THEY WERE FOUND AT THEEND OF EACH JOB PHASE. SEE SPECIFICATIONS.
1. SEE PHASING LEGEND. PHASE B AREA AND ADJACENT WALLS ARE NOT TO BEDISTURBED DURING PHASE A TO PREVENT PHASE B HAZARDOUS MATERIALS FROMBEING DISTURBED. THE BOUNDARY WALL SEPARATING PHASE A AND PHASE B IS NOTTO BE DISTURBED DURING PHASE A.2. CONTACT OWNER UPON DISCOVERY OF ANY ASBESTOS-CONTAINING MATERIALSOR OTHER SUSPECTED HAZARDOUS MATERIALS NOT SHOW TO BE REMOVED ORALTERED WITHIN THE PROJECT SCOPE.3. FIELD VERIFY EXISTING CONDITIONS PRIOR TO COMMENCEMENT OF DEMOLITIONAND NEW WORK. INFORMATION SHOWN IS BASED ON THE EXISTING DRAWINGSPROVIDED BY THE OWNER. GENERAL CONTRACTOR AND SUB-CONTRACTORS ARE TOVERIFY EXISTING CONDITIONS PRIOR TO BID AND PRIOR TO CONSTRUCTION.4. CONTRACTOR SHALL PHOTOGRAPH AND VIDEO ALL SPACES PRIOR TOCOMMENCEMENT OF RENOVATION/NEW WORK TO DOCUMENT PRE-CONSTRUCTIONCONDITIONS. PROVIDE ARCHITECT WITH ELECTRONIC COPIES OF PHOTOGRAPHSAND VIDEO.5. CORE DRILLING IN EXISTING SLAB FOR NEW UTILITY SERVICE IS NOT SHOWN ONTHIS PLAN. SEE MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FOR REQUIREDUTILITY ROUTING.6. SEE MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS FOR ADDITIONAL ITEMSTO REMAIN AND BE PROTECTED THROUGHOUT CONSTRUCTION, INCLUDING DATA ANDPOWER CONDUITS, LIGHTS, PIPES AND DUCTWORK.7. ITEMS TO BE SALVAGED AND REMOVED BY OWNER PRIOR TO DEMOLITION AREIDENTIFIED WITHIN THE SPECIFICATIONS.8. PROTECT EXISTING BUILDING SCOPE NOT INCLUDED INDEMOLITION/CONSTRUCTION SCOPE. REPAIR OR REPLACEMENT DAMAGED AREASNOT IN THIS SCOPE SHALL BE INCLUDED IN THE WORK, WITH NO ADDITIONAL COST TOTHE OWNER.9. ELECTRICAL CONTRACTOR IS TO VERIFY ALL CEILING MOUNTED ELECTRICALDEVICES ARE IN WORKING CONDITION AT COMMENCEMENT OFDEMOLITION/CONSTRUCTION. SEE ELECTRICAL DRAWINGS AND SPECS FOR ALLSCOPE RELATED TO CEILING MOUNTED DEVICES PRIOR TO COMMENCEMENT OFDEMOLITION/CONSTRUCTION.10. SEE ELECTRICAL FOR FULL SCOPE AND COORDINATION OF ALL LIGHTINGDEMOLITION/CONSTRUCTION FOR BASE BID AND ALTERNATE NO. 1.11. ELEVATORS ARE NOT PART OF THE PROJECT SCOPE BUT MAY BE USED DURINGTHE DEMOLITION AND CONSTRUCTION PERIOD. ELEVATORS SHOULD BE PROTECTED,CLEANED AND RETURNED TO THE CONDITION IN WHICH THEY WERE FOUND AT THEEND OF EACH JOB PHASE. SEE SPECIFICATIONS.
N
PHASE B WORK - NOTE TO CONTRACTORS:
1. DURING THE PROCESS OF INSTALLING HANGERS, SOFFITS, FAN COILS, METAL PAN COVERS, NEW PARTITIONS OR ANY OTHERMATERIAL OR EQUIPMENT AT THE CEILINGS OF THE EXISTING RESIDENT ROOMS ON FLOORS 2 THRU 18, THE CONTRACTORSHALL NOT COME IN CONTACT WITH THE SPRAY APPLIED TEXTURED CEILING MATERIAL THAT IS TO REMAIN IN PLACE AFTER THEPARTIAL ABATEMENT OF ASBESTOS FROM THE CEILINGS. CONTAMINATION OF THESE SPACES CAUSED BY DAMAGE TO THECEILING MATERIAL SHALL BE CLEANED UP AT THE CONTRACTOR'S EXPENSE, INCLUDING BUT NOT LIMITED TO, COSTSASSOCIATED WITH CLEARING THESE SPACES FOR RE-ACCESS, I.E. AIR SAMPLING.
2. DURING THE PROCESS OF INSTALLING UL RATED RACEWAYS AT CORRIDOR WALL PENETRATION, INSTALLATION OF NEWPARTITIONS, THE CONTRACTOR SHALL NOT DISTURB THE EXISTING GYPSUM BOARD IN ANY FASHION. NO PENETRATIONS WILLBE ALLOWED ONCE THE ASBESTOS ABATEMENT HAS BEEN COMPLETED BY THE ABATEMENT CONTRACTOR.
PHASE A WORK - NOTE TO CONTRACTORS:
1. NO PENETRATIONS OR ATTACHMENTS TO THE EXISTING GYPSUM BOARD PARTITIONS WILL BE ALLOWED ONCE THEASBESTOS ABATEMENT HAS BEEN COMPLETED BY THE ABATEMENT CONTRACTOR.
2. THE CONTRACTOR SHALL NOT COME IN CONTACT WITH THE GYPSUM BOARD MATERIAL THAT IS TO REMAIN IN PLACE AFTERTHE PARTIAL ABATEMENT OF ASBESTOS FROM THE CORRIDOR PARTITIONS ON THE EXISTING FLOORS 2 THRU 18 AND OTHERPARTITIONS ON THE BASEMENT AND GROUND LEVELS. CONTAMINATION OF THESE SPACES CAUSED BY DAMAGE TO THEGYPSUM BOARD MATERIAL SHALL BE CLEANED UP AT THE CONTRACTOR'S EXPENSE, INCLUDING BUT NOT LIMITED TO, COSTSASSOCIATED WITH CLEARING THESE SPACES FOR RE-ACCESS, I.E. AIR SAMPLING.
REFERENCED ON: 1/4" = 1'-0"A2.21 TYPICAL REFLECTED CEILING PLAN - LEVELS 2-17
PHASE A - TYPICAL RCP KEYNOTES
LEGEND
PHASE B - TYPICAL RCP KEYNOTESPHASE B - GENERAL RCP NOTES
PHASE A - GENERAL RCP NOTES
A2.2
TYPI
CAL R
EFLE
CTED
CEILI
NG P
LAN,
LEVE
LS 2-
17
RMB
SAL
1
ED
C
2 3 4
BA
1 2 3 4
UNIV
ERSI
TY O
F SO
UTH
CARO
LINA
MECH
ANIC
AL R
ENOV
ATIO
NSSO
UTH
TOW
ER
5 6 7
E
SHEET:
SHEE
T TI
TLE:
DRAW
N BY
:
D
REV.
DRAW
ING:
DESC
RIPT
ION
03/15
/12DA
TE:
PROJ
ECT
TITL
E:
C
CHEC
KED
BY:
DATE
ORIG
. BY
DRAW
N BY
5 6
Facsimile: (803) 791-0830
B
SEAL
SEAL
Swyg
ert &
Ass
ocia
tes
C O
N S
U L
T I
N G
E
N G
I N
E E
R S
Post Office Box 11686
DBA Swygert & Assoc. Ltd.
A
Telephone: (803) 791-9300
Columbia, S.C. 29211
mail@
swygert-associates.com
7
STAT
E PR
OJEC
T NU
MBER
H27
-608
2-NA
THIS DRAWING AND THE
DESIGN THEREON ARE THE
PROPERTY OF SW
YGERT &
ASSOCIATES, LTD. THE
REPRODUC
TION
, COPYING, OR
USE OF THIS DRAWING
WITHOU
T THE WRITTEN
CON
SENT OF SW
YGERT &
ASSOCIATES IS PROHIBITED
AND ANY INFRINGEMENT WILL
BE SUBJECT TO LEGAL ACTION
.
BID
DOCU
MENT
S
8'-7"EXPOSED
STRUCTURE
8'-7"EXPOSED
STRUCTURE
OPEN TO ABOVE
OPEN TO ABOVE
OPEN TO ABOVE
7'-1" CEILINGHEIGHT INELEVATOR CAB
8' - 6"8' - 6"8' - 6"8' - 6"8' - 6"
8' - 6"
8' - 6"
8' - 6" 8' - 6" 8' - 6" 8' - 6" 8' - 6"
8' - 6"
7' - 2 5/8"
EXPOSEDSTRUCTURE
EXPOSEDSTRUCTURE
SLOPED
SLOPED
7' - 3"
7' - 2 1/4"
RESIDENT1808
1
1
1
HALLH1802
HALLH1801
HALLH1803
RESIDENT1809
RESIDENT1810
RESIDENT1811
RESIDENT1812
COMMUNITY1813
RESIDENT1801
RESIDENT1802
RESIDENT1803
RESIDENT1804
RESIDENT1805
RESIDENT1806
RESIDENT1807
AA
H
H
H
H
A A A A A
H
H
H
AAABB B BB
BB B BB
CC C CC
CC C CC
EE E E E
EEEEE
E
E
WOMEN1815
CUST1814
ELEC1816
CHASE1817
RESIDENT1800
ALIGN ALIGN ALIGN ALIGN
ALIGN ALIGN ALIGN ALIGN ALIGN
ALIGN
MIN.4"
MIN.8"
MIN.8"
MIN.4"
1' - 4" 1' - 4"
MIN.4"
MIN.8"
F.V.
2' - 0
1/4"
F.V.
1' - 9
3/4"
F.V.12' - 9 5/8"
F.V.12' - 7 1/4"
F.V.12' - 7 1/8"
F.V.12' - 7 1/8"
F.V.12' - 9 5/8"
F.V.
16' -
3 3/4"
F.V.
17' -
8 3/8"
F.V.
12' -
5 7/8"
F.V.
16' -
1 3/4"
7' - 3"
7' - 3"
F.V.12' - 9 5/8"
F.V.12' - 7 1/4"
F.V.12' - 7 1/8"
F.V.12' - 7 1/8"
F.V.12' - 9 5/8"
F.V.
16' -
1 3/4"
F.V.
17' -
9 7/8"
F.V.
16' -
3 3/4"
D D D
F F F
DDDDD
D
D
D D
D
FFFFF
F
F
FF
F
G
8' - 5"
7' - 6"7' - 6"
7' - 6"7' - 6"7' - 6"
7' - 6"
7' - 6"
7' - 6" 7' - 6" 7' - 6" 7' - 6" 7' - 6"
7' - 6"
1' - 4
"
8' - 1
"
8' - 1
"
8' - 1
"
8' - 1
"
8' - 1"
8' - 1"
8' - 1"
8' - 1"
8' - 1
"
8' - 1
"
8' - 1
"
8' - 1"
8' - 1"
7' - 2 5/8"
7' - 2
5/8"
7' - 2
5/8"
7' - 2
5/8"
7' - 2 5/8" 7' - 2 5/8" 7' - 2 5/8" 7' - 2 5/8"
7' - 2
5/8"
7' - 2 5/8"7' - 2 5/8"7' - 2 5/8"7' - 2 5/8"
7
A3.2
TYP.
8
A3.2
TYP.
6
A3.2
A3.11
J
J
J
C
C
8'-1"
5
A2.32
PHASE ASOFFIT
C
C
CONSTRUCTION PHASING LINE.
PHASE B CONSTRUCTION AREA
AREA NOT TO BE DISTURBED BYCONSTRUCTION
PHASE A CONSTRUCTION AREA, LIMITEDSCOPE IN PHASE B, SEE ALL NOTES
DEMOLITION - TO BE NOTED ONDEMO PLANS ONLY
EXISTING TEXTURE CEILING(ASBESTOS)
1. SEE PHASING LEGEND. PHASE B AREA AND ADJACENT WALLS ARE NOT TO BEDISTURBED DURING PHASE A TO PREVENT PHASE B HAZARDOUS MATERIALS FROMBEING DISTURBED. THE BOUNDARY WALL SEPARATING PHASE A AND PHASE B IS NOTTO BE DISTURBED DURING PHASE A.2. CONTACT OWNER UPON DISCOVERY OF ANY ASBESTOS-CONTAINING MATERIALSOR OTHER SUSPECTED HAZARDOUS MATERIALS NOT SHOW TO BE REMOVED ORALTERED WITHIN THE PROJECT SCOPE.3. FIELD VERIFY EXISTING CONDITIONS PRIOR TO COMMENCEMENT OF DEMOLITIONAND NEW WORK. INFORMATION SHOWN IS BASED ON THE EXISTING DRAWINGSPROVIDED BY THE OWNER. GENERAL CONTRACTOR AND SUB-CONTRACTORS ARE TOVERIFY EXISTING CONDITIONS PRIOR TO BID AND PRIOR TO CONSTRUCTION.4. CONTRACTOR SHALL PHOTOGRAPH AND VIDEO ALL SPACES PRIOR TOCOMMENCEMENT OF RENOVATION/NEW WORK TO DOCUMENT PRE-CONSTRUCTIONCONDITIONS. PROVIDE ARCHITECT WITH ELECTRONIC COPIES OF PHOTOGRAPHSAND VIDEO.5. CORE DRILLING IN EXISTING SLAB FOR NEW UTILITY SERVICE IS NOT SHOWN ONTHIS PLAN. SEE MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FOR REQUIREDUTILITY ROUTING.6. SEE MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS FOR ADDITIONAL ITEMSTO REMAIN AND BE PROTECTED THROUGHOUT CONSTRUCTION, INCLUDING DATA ANDPOWER CONDUITS, LIGHTS, PIPES AND DUCTWORK.7. ITEMS TO BE SALVAGED AND REMOVED BY OWNER PRIOR TO DEMOLITION AREIDENTIFIED WITHIN THE SPECIFICATIONS.8. PROTECT EXISTING BUILDING SCOPE NOT INCLUDED INDEMOLITION/CONSTRUCTION SCOPE. REPAIR OR REPLACEMENT DAMAGED AREASNOT IN THIS SCOPE SHALL BE INCLUDED IN THE WORK, WITH NO ADDITIONAL COST TOTHE OWNER.9. ELECTRICAL CONTRACTOR IS TO VERIFY ALL CEILING MOUNTED ELECTRICALDEVICES ARE IN WORKING CONDITION AT COMMENCEMENT OFDEMOLITION/CONSTRUCTION. SEE ELECTRICAL DRAWINGS AND SPECS FOR ALLSCOPE RELATED TO CEILING MOUNTED DEVICES PRIOR TO COMMENCEMENT OFDEMOLITION/CONSTRUCTION.10. SEE ELECTRICAL FOR FULL SCOPE AND COORDINATION OF LIGHTINGDEMOLITION/CONSTRUCTION FOR BASE BID AND ALTERNATE NO. 1.11. ELEVATORS ARE NOT PART OF THE PROJECT SCOPE BUT MAY BE USED DURINGTHE DEMOLITION AND CONSTRUCTION PERIOD. ELEVATORS SHOULD BE PROTECTED,CLEANED AND RETURNED TO THE CONDITION IN WHICH THEY WERE FOUND AT THEEND OF EACH JOB PHASE. SEE SPECIFICATIONS.
1. SEE PHASING LEGEND. PHASE B AREA AND ADJACENT WALLS ARE NOT TO BEDISTURBED DURING PHASE A TO PREVENT PHASE B HAZARDOUS MATERIALS FROMBEING DISTURBED. THE BOUNDARY WALL SEPARATING PHASE A AND PHASE B IS NOTTO BE DISTURBED DURING PHASE A.2. CONTACT OWNER UPON DISCOVERY OF ANY ASBESTOS-CONTAINING MATERIALSOR OTHER SUSPECTED HAZARDOUS MATERIALS NOT SHOW TO BE REMOVED ORALTERED WITHIN THE PROJECT SCOPE.3. FIELD VERIFY EXISTING CONDITIONS PRIOR TO COMMENCEMENT OF DEMOLITIONAND NEW WORK. INFORMATION SHOWN IS BASED ON THE EXISTING DRAWINGSPROVIDED BY THE OWNER. GENERAL CONTRACTOR AND SUB-CONTRACTORS ARE TOVERIFY EXISTING CONDITIONS PRIOR TO BID AND PRIOR TO CONSTRUCTION.4. CONTRACTOR SHALL PHOTOGRAPH AND VIDEO ALL SPACES PRIOR TOCOMMENCEMENT OF RENOVATION/NEW WORK TO DOCUMENT PRE-CONSTRUCTIONCONDITIONS. PROVIDE ARCHITECT WITH ELECTRONIC COPIES OF PHOTOGRAPHSAND VIDEO.5. CORE DRILLING IN EXISTING SLAB FOR NEW UTILITY SERVICE IS NOT SHOWN ONTHIS PLAN. SEE MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FOR REQUIREDUTILITY ROUTING.6. SEE MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS FOR ADDITIONAL ITEMSTO REMAIN AND BE PROTECTED THROUGHOUT CONSTRUCTION, INCLUDING DATA ANDPOWER CONDUITS, LIGHTS, PIPES AND DUCTWORK.7. ITEMS TO BE SALVAGED AND REMOVED BY OWNER PRIOR TO DEMOLITION AREIDENTIFIED WITHIN THE SPECIFICATIONS.8. PROTECT EXISTING BUILDING SCOPE NOT INCLUDED INDEMOLITION/CONSTRUCTION SCOPE. REPAIR OR REPLACEMENT DAMAGED AREASNOT IN THIS SCOPE SHALL BE INCLUDED IN THE WORK, WITH NO ADDITIONAL COST TOTHE OWNER.9. ELECTRICAL CONTRACTOR IS TO VERIFY ALL CEILING MOUNTED ELECTRICALDEVICES ARE IN WORKING CONDITION AT COMMENCEMENT OFDEMOLITION/CONSTRUCTION. SEE ELECTRICAL DRAWINGS AND SPECS FOR ALLSCOPE RELATED TO CEILING MOUNTED DEVICES PRIOR TO COMMENCEMENT OFDEMOLITION/CONSTRUCTION.10. SEE ELECTRICAL FOR FULL SCOPE AND COORDINATION OF ALL LIGHTINGDEMOLITION/CONSTRUCTION FOR BASE BID AND ALTERNATE NO. 1.11. ELEVATORS ARE NOT PART OF THE PROJECT SCOPE BUT MAY BE USED DURINGTHE DEMOLITION AND CONSTRUCTION PERIOD. ELEVATORS SHOULD BE PROTECTED,CLEANED AND RETURNED TO THE CONDITION IN WHICH THEY WERE FOUND AT THEEND OF EACH JOB PHASE. SEE SPECIFICATIONS.
INSTALL GRID AND 2'X2' ACT CEILING, SEE FINISHSCHEDULE. SEE ELECTRICAL FOR NEW LIGHTS. (EXISTINGAPC WALL ANGLE TO REMAIN, SEE DEMOLITION KEYNOTES.)
PAINT EXISTING METAL PERIMETER SOFFIT ENTIREPERIMETER OF BUILDING.
INSTALL NEW GWB CEILING TO MATCH EXISTING. NEWLIGHTS, SEE ELECTRICAL.
EXISTING GRILL TO BE REMOVED AND GWB BOARD TO BEPATCHED BY OWNERS. G.C. TO PAINT AT EXPOSED AREAS.
OPENING IN CONCRETE ROOF DECK TO BE CUT ANDCAPPED IN PHASE A. PROVIDE SHEET ROCK SOFFIT INPHASE A TO CONCEAL ROOF OPENING. EXISTING CHASEWALL TO REMAIN DURING PHASE A. SEE DETAIL 2/A2.3 FORPHASE A SOFFIT PLAN.
1
2
3
4
5
INSTALL NEW SOFFIT. SEE MECHANICAL AND DETAIL 6/A3.2 FOR FULLCOORDINATION AND EXTENT OF SCOPE.
REINSTALL EXISTING LIGHT FIXTURE. SEE ELECTRICAL FOR FULLSCOPE AND COORDINATION OF LIGHTINGDEMOLITION/CONSTRUCTION FOR BASE BID AND ALTERNATE NO. 1.
SEE ELECTRICAL DRAWINGS FOR FULL SCOPE AND COORDINATIONOF ALL LIGTHING DEMOLLITION/CONSTRUCTION FOR BASE BID ANDALTERNATE NO. 1.
NEW FAN COIL UNIT. SEE MECHANICAL.
EXISTING LIGHT TO REMAIN. G.C. TO VERIFY EXISTING LOCATIONSARE NOT IN CONFLICT WITH NEW MECHANICAL SYSTEMS PRIOR TOEND OF ASBESTOS ABATEMENT DEMOLITION, TYP. G.C. TORELOCATE AND COORDINATE NEW LOCATION WITH ARCHITECT INFIELD, IF IN CONFLICT WITH NEW MECHANICAL. SEE ELECTRICAL FORFULL SCOPE AND COORDINATION OF LIGHTINGDEMOLITION/CONSTRUCTION FOR BASE BID AND ALTERNATE NO. 1.
NEW METAL PIPE ENCLOSURE. FIELD VERIFY AND COORDINATEDIMENSIONS AND LAYOUT WITH MECHANICAL PIPING ANDELECTRICAL. SEE DETAIL 8/A3.2.
APPLY SPRAY TEXTURE FINISH TO MATCH EXISTING ADJACENTCEILING WHERE EXISTING METAL SOFFIT HAS BEEN DECREASED INSIZE AND UNDERSIDE OF DECK /CEILING HAS BEEN EXPOSED. SEESPEC.
INSTALL NEW STEEL SUPPORT ANGLE AND NEW METAL SOFFIT. SEEDETAIL 7/A3.2 FOR FULL COORDINATION AND EXTENT OF SCOPE.
SELECTIVE REMOVAL OF APC CEILING TILE ONLY INSTALLED INPHASE A TO ALLOW FOR REQUIRED MECHANICAL, ELECTRICAL ANDPLUMBING CONNECTIONS AND/OR REMOVAL OF PIPING. SEEMECHANICAL, ELECRICAL, AND PLUMBING. PROTECT EXISTINGCEILING TILE, GRID AND AND ADJACENT CEILING MATERIALS ANDREINSTALL CEILING TILE AFTER REMOVAL OF PHASE B PLUMBINGSCOPE IS COMPLETE.
A
B
C
D
E
F
G
H
J
N
PHASE A WORK - NOTE TO CONTRACTORS:
1. NO PENETRATIONS OR ATTACHMENTS TO THE EXISTING GYPSUM BOARD PARTITIONS WILL BE ALLOWED ONCE THEASBESTOS ABATEMENT HAS BEEN COMPLETED BY THE ABATEMENT CONTRACTOR.
2. THE CONTRACTOR SHALL NOT COME IN CONTACT WITH THE GYPSUM BOARD MATERIAL THAT IS TO REMAIN IN PLACE AFTERTHE PARTIAL ABATEMENT OF ASBESTOS FROM THE CORRIDOR PARTITIONS ON THE EXISTING FLOORS 2 THRU 18 AND OTHERPARTITIONS ON THE BASEMENT AND GROUND LEVELS. CONTAMINATION OF THESE SPACES CAUSED BY DAMAGE TO THEGYPSUM BOARD MATERIAL SHALL BE CLEANED UP AT THE CONTRACTOR'S EXPENSE, INCLUDING BUT NOT LIMITED TO, COSTSASSOCIATED WITH CLEARING THESE SPACES FOR RE-ACCESS, I.E. AIR SAMPLING.
PHASE B WORK - NOTE TO CONTRACTORS:
1. DURING THE PROCESS OF INSTALLING HANGERS, SOFFITS, FAN COILS, METAL PAN COVERS, NEW PARTITIONS OR ANY OTHERMATERIAL OR EQUIPMENT AT THE CEILINGS OF THE EXISTING RESIDENT ROOMS ON FLOORS 2 THRU 18, THE CONTRACTORSHALL NOT COME IN CONTACT WITH THE SPRAY APPLIED TEXTURED CEILING MATERIAL THAT IS TO REMAIN IN PLACE AFTER THEPARTIAL ABATEMENT OF ASBESTOS FROM THE CEILINGS. CONTAMINATION OF THESE SPACES CAUSED BY DAMAGE TO THECEILING MATERIAL SHALL BE CLEANED UP AT THE CONTRACTOR'S EXPENSE, INCLUDING BUT NOT LIMITED TO, COSTSASSOCIATED WITH CLEARING THESE SPACES FOR RE-ACCESS, I.E. AIR SAMPLING.
2. DURING THE PROCESS OF INSTALLING UL RATED RACEWAYS AT CORRIDOR WALL PENETRATION, INSTALLATION OF NEWPARTITIONS, THE CONTRACTOR SHALL NOT DISTURB THE EXISTING GYPSUM BOARD IN ANY FASHION. NO PENETRATIONS WILLBE ALLOWED ONCE THE ASBESTOS ABATEMENT HAS BEEN COMPLETED BY THE ABATEMENT CONTRACTOR.
8'-0"
EXISTING TO REMAIN
EXISTING SPRAY ONTEXTURED CEILINGOUTSIDE OF SOFFIT AREATO REMAIN DURING PHASEA. SEE NOTES FOR PHASE BSCOPE.
SHEET ROCK SOFFIT ON METALSTUD FRAMING TO BE INSTALLEDDURING PHASE A ANDDEMOLISHED TO ALLOW FORNEW CHASE CONSTRUCTIONDURING PHASE B.
EXISTING CHASE WALL TOREMAIN DURING PHASE A,DEMOLISHED DURING PHASE B.
REMOVE/ABATE PARITAL EXISTINGASBESTOS CONTAINING SPRAY TEXTURECEILING TO ALLOW FOR PHASE A SHEETROCK SOFFIT. FULL REMOVAL OF SPRAYTEXTURED CEILING TO OCCUR DURINGPHASE B.
V.I.F.3' - 0"
ALIGN
3A2.3
2"2' - 9"1"
EXISTING CHASE WALL TO REMAINTHRU PHASE A, DEMOLISH DURINGPHASE B
8'-0" (HEIGHT)SHEETROCKSOFFIT ON 3 5/8" METALFRAMING INSTALLEDDURING PHASE A TOCONCEAL ROOM OPENING.DEMOLISH DURING PHASE B.
SEE MECHANICAL FOR ROOFCURB DETAILS
NEW OPENING IN CONCRETEROOF DECK, COORDINATEWITH STRUCTURAL ANDMECHANICAL
EXISTIN EXTERIOR CONCRETEWALL
REFERENCED ON: 1/4" = 1'-0"A2.31 18TH FLOOR REFLECTED CEILING PLAN
LEGEND
PHASE B - GENERAL RCP NOTES
PHASE A - GENERAL RCP NOTES PHASE A - TYPICAL RCP KEYNOTES
A2.3
18TH
FLO
OR R
EFLE
CTED
CEILI
NG P
LAN
RMB
SAL
PHASE B - TYPICAL RCP KEYNOTES
REFERENCED ON: 1/2" = 1'-0"A2.3 A2.32 ROOM 1813 PHASE A SOFFIT PLAN
REFERENCED ON: 1/2" = 1'-0"A2.3 A2.33 ROOM 1813 PHASE A SOFFIT SECTION
1
ED
C
2 3 4
BA
1 2 3 4
UNIV
ERSI
TY O
F SO
UTH
CARO
LINA
MECH
ANIC
AL R
ENOV
ATIO
NSSO
UTH
TOW
ER
5 6 7
E
SHEET:
SHEE
T TI
TLE:
DRAW
N BY
:
D
REV.
DRAW
ING:
DESC
RIPT
ION
03/15
/12DA
TE:
PROJ
ECT
TITL
E:
C
CHEC
KED
BY:
DATE
ORIG
. BY
DRAW
N BY
5 6
Facsimile: (803) 791-0830
B
SEAL
SEAL
Swyg
ert &
Ass
ocia
tes
C O
N S
U L
T I
N G
E
N G
I N
E E
R S
Post Office Box 11686
DBA Swygert & Assoc. Ltd.
A
Telephone: (803) 791-9300
Columbia, S.C. 29211
mail@
swygert-associates.com
7
STAT
E PR
OJEC
T NU
MBER
H27
-608
2-NA
THIS DRAWING AND THE
DESIGN THEREON ARE THE
PROPERTY OF SW
YGERT &
ASSOCIATES, LTD. THE
REPRODUC
TION
, COPYING, OR
USE OF THIS DRAWING
WITHOU
T THE WRITTEN
CON
SENT OF SW
YGERT &
ASSOCIATES IS PROHIBITED
AND ANY INFRINGEMENT WILL
BE SUBJECT TO LEGAL ACTION
.
BID
DOCU
MENT
S
REMOVE EXISTING CHEST OF DRAWERS
EXISTING WARDROBE. PROTECTTHROUGHOUT CONSTRUCTION
EXISTING FLOORING TO BEREMOVEDSEE DEMOLITION, FLOOR, ANDFINISH PLAN
EXISTING WALL PANEL TO BE PROTECTED ANDNOT DISTURBED THROUGHOUT CONSTRUCTION.WALL PANEL FACE CONTAINS ASBESTOS ANDMAY NOT BE DISTURBED
REMOVE ALL EXISTINGUTILITES THIS AREA,SEE MECHANICAL,ELECTRICAL AND
PLUMBING.
REMOVE EXISTING WOOD PARTITIONS
FILL HOLE(S) IN EXISTING FLOORSLAB THIS AREA. SEE STRUCTURAL
DRAWINGS FOR DETAILS.
EXISTING WARDROBE. PROTECTTHROUGHOUT CONSTRUCTION
NEW 3-5/8" METAL STUD WALL WITH5/8" GYPSUM WALL BOARD EACH SIDE.EXTEND WALL TO SOFFIT/CEILING ABOVE
5/8" GYPSUM WALL BOARD ON 1-5/8" METAL STUD FURRING. HOLD
OFF OF EXIST. WALL PANEL.
CAULK JOINT
NEW 1X3 WOOD TRIM PIECE. STAIN TOMATCH EXISTING WARDROBE.
EXISTING WALL PANEL TO BE PROTECTED ANDNOT DISTURBED THROUGHOUT CONSTRUCTION.WALL PANEL FACE CONTAINS ASBESTOS ANDMAY NOT BE DISTURBED
NEW WOOD TRIM AND 1/4" PLYWOOD PANEL.STAIN TO MATCH EXISTING WARDROBE.
DEMO EXISTING WALL
EXISTING SLAB OPENING
PROTECT EXISTING WALL
SECURE METAL DECKING TO BOTTOM SIDEOF SLAB AND FILL EXISTING HOLE IN SLABWITH CONCRETE. FINISH FLUSH WITHEXISTING SLAB LEVEL.
NEW 3-5/8" METAL STUD WALL, 5/8"GYPSUM WALL BOARD, ONE SIDE, SEEPARTITION TYPES.
CAULK JOINT
DO NOT DISTURB EXISTING ASBESTOSCONTAINING WALL
CAULK JOINT
OPENING
2 1/2" USG STEEL C-H STUDAT 24" O.C. MAX
USG STEEL J RUNNER
2 LAYERS 1/2" GYPSUMWALL BOARD 1" GYPSUM
LINER PANEL
PROTECT EXISTING ASBESTOS WALL
USG CORNER REINFORCEMENT
USG STEEL J RUNNER
USG STEEL J RUNNER
ALIGN GWB WITH EDGE OFCONCRETE COLUMN.CAULK JOINT
FACE
OF
EXIS
TING
WAL
LTO
C-H
STU
D
1" DIMENSIONS OF OPENING VARIES BY FLOOR 2"
EQ.
3' - 7
"EQ
.DI
MENS
IONS
OF
OPEN
ING
VARI
ES B
Y FL
OOR
CONS
ISTE
NT O
NEV
ERY
FLOO
R
13"17"21"23"27"29"31"33"
CAULK JOINT
FLOOR 3FLOORS 4, 5, 6, 7FLOORS 8, 9FLOORS 10, 11FLOORS 12, 13FLOORS 14, 15FLOORS 16, 17FLOORS 18, ROOF
INSIDE FACE OF SHAFT WALLTO EDGE OF OPENING
FLOO
R 3
FLOO
R 4
FLOO
R 5
FLOO
R 6
FLOO
RS 7-
18, R
OOF
23"
25"
31"
39"
45"
4 7/8"
3' - 1
0"5 1
/4"3'
- 10 1
/2"4 1
/2"4 1
/2"
FACE OF CONCRETE WALLTO EDGE OF OPENING
1" GYPSUMLINER PANEL
2 LAYERS 1/2" GYPSUMWALL BOARD
USG STEEL J RUNNER
TWO HOUR FIRE RATED CONSTRUCTION
2 1/2" USG STEEL C-H STUDAT 24" O.C. MAX
4' - 3
"
PIPE DRAIN
PREFINISHED .080 GAUGE ALUM.BREAK METAL SHROUD. SEE
SPECS
2-SIDEDGLAZING TAPE
EXISTING CONCRETECOLUMN
PROTECT EXISTINGASBESTOS CONTAINING
STUD WALL
6"
6"
CAULK JOINT
CAULK JOINT
1 LAYER 5/8" GYPSUM WALLBOARD EACH SIDE
CONCRETE SLAB AT ROOF ORFLOOR ABOVE
WALL FINISH, SEE FINISHSCHEDULE
STEEL RUNNER ATTACHED TOCONCRETE SLAB AT 12" O.C. MAX.@ TOP AND BOTTOM OF WALL
CONCRETE SLABFINISH FLOOR MATERIAL,SEE FINISH SCHEDULE
CEILING WHERE INDICATED ONREFLECTED CEILING PLANSWHERE OCCURS
BASE, SEE FINISH SCHEDULE
AT FIRE-RATED WALLSEXTENDING TO DECK, EXTENDGYPSUM BOARD TIGHT TODECK AND SEAL WITH FIRECAULKING. PACK ALL VOIDSWITH FIRE-SAFING MATERIAL
1-HOUR RATED WALL.BASIS FOR DESIGN:UL DESIGN U465
STEEL STUDS @ 16" O.C. MAX.(SEE SPECIFIC PARTITIONTYPE FOR SIZE)
ACOUSTICAL BATTINSULATION @ * CONDITION(SEE LEGEND FOR SIZE)
2 LAYERS 1/2" GYPSUM WALLBOARD
STEEL DECK OR CONCRETE SLABAT ROOF OR FLOOR ABOVE
WALL FINISH, SEE FINISHSCHEDULE
STEEL J RUNNER ATTACHED TOCONCRETE SLAB AT 12" O.C. MAX.@ TOP AND BOTTOM OF WALL
CONCRETE SLAB
FINISH FLOOR MATERIAL,SEE FINISH SCHEDULE
CEILING WHERE INDICATED ONREFLECTED CEILING PLANSWHERE OCCURS
BASE, SEE FINISH SCHEDULE
STEEL C-H STUDS @ 16" O.C.MAX. (SEE SPECIFIC PARTITIONTYPE FOR SIZE)
AT FIRE-RATED WALLSEXTENDING TO DECK, EXTENDGYPSUM BOARD TIGHT TODECK AND SEAL WITH FIRECAULKING. PACK ALL VOIDSWITH FIRE-SAFING MATERIAL
2-HOUR RATED SHAFT WALL.BASIS FOR DESIGN:UL DESIGN U415, SYSTEM B
LAYER 5/8" GYPSUM WALLBOARD
STEEL DECK OR CONCRETE SLABAT ROOF OR FLOOR ABOVE
WALL FINISH, SEE FINISHSCHEDULE
STEEL J RUNNER ATTACHED TOCONCRETE SLAB AT 12" O.C. MAX.@ TOP AND BOTTOM OF WALL
CONCRETE SLAB
FINISH FLOOR MATERIAL,SEE FINISH SCHEDULE
CEILING WHERE INDICATED ONREFLECTED CEILING PLANSWHERE OCCURS
BASE, SEE FINISH SCHEDULE
STEEL C-H STUDS @ 16" O.C.MAX. (SEE SPECIFIC PARTITIONTYPE FOR SIZE)
AT FIRE-RATED WALLSEXTENDING TO DECK, EXTENDGYPSUM BOARD TIGHT TODECK AND SEAL WITH FIRECAULKING. PACK ALL VOIDSWITH FIRE-SAFING MATERIAL
1-HOUR RATED SHAFT WALL.BASIS FOR DESIGN:UL DESIGN U415, SYSTEM A
M1M2M3M4M6M8
M2A*
MATERIAL FINISHCONSTRUCTION
SIZE
SEE CHART BELOW
SEE CHART BELOW
SEE PARTITIONSECTION
1-1/2" METAL STUD2-1/2" METAL STUD3-5/8" METAL STUD4" METAL STUD6" METAL STUD8" METAL STUD
INSULATIONDESIGNATION
S2 2-1/2" C-H STUD (SHAFT WALL)
1 LAYER 5/8" GYPSUM WALLBOARD
STEEL DECK OR CONCRETE SLABAT ROOF OR FLOOR ABOVE
WALL FINISH, SEE FINISHSCHEDULE
STEEL RUNNER ATTACHED TOCONCRETE SLAB AT 12" O.C. MAX.@ TOP AND BOTTOM OF WALL
CONCRETE SLAB
FINISH FLOOR MATERIAL,SEE FINISH SCHEDULE
CEILING WHERE INDICATED ONREFLECTED CEILING PLANSWHERE OCCURS
BASE, SEE FINISH SCHEDULE
STEEL STUDS @ 16" O.C. MAX.(SEE SPECIFIC PARTITION TYPEFOR SIZE)
ACOUSTICAL BATTINSULATION @ * CONDITION(SEE LEGEND FOR SIZE)
REFERENCED ON: 1 1/2" = 1'-0"A3.1 D1.25 CHASE 1 DETAIL - DEMO
REFERENCED ON: 1 1/2" = 1'-0"A3.1 A1.26 CHASE 1 DETAIL
REFERENCED ON: 1 1/2" = 1'-0"A3.1 D1.23 CHASE 2 DETAIL - DEMO
REFERENCED ON: 1 1/2" = 1'-0"A3.1 A1.24 CHASE 2 DETAIL
REFERENCED ON: 3" = 1'-0"A3.1 A1.21 SHAFT WALL DETAILS - UL DESIGN U415, SYSTEM B
REFERENCED ON: 1 1/2" = 1'-0"A3.1 A1.22 TYP PIPE DRAIN ENCLOSURE
A3.1
DETA
ILSRM
BSA
L
INTERIOR PARTITION 1 1/2" = 1'-0"M#A INTERIOR PARTITION
1 1/2" = 1'-0"S#CINTERIOR PARTITION 1 1/2" = 1'-0"S#B
PARTITION TYPE LEGEND
INTERIOR PARTITION 1 1/2" = 1'-0"M#D
1
ED
C
2 3 4
BA
1 2 3 4
UNIV
ERSI
TY O
F SO
UTH
CARO
LINA
MECH
ANIC
AL R
ENOV
ATIO
NSSO
UTH
TOW
ER
5 6 7
E
SHEET:
SHEE
T TI
TLE:
DRAW
N BY
:
D
REV.
DRAW
ING:
DESC
RIPT
ION
03/15
/12DA
TE:
PROJ
ECT
TITL
E:
C
CHEC
KED
BY:
DATE
ORIG
. BY
DRAW
N BY
5 6
Facsimile: (803) 791-0830
B
SEAL
SEAL
Swyg
ert &
Ass
ocia
tes
C O
N S
U L
T I
N G
E
N G
I N
E E
R S
Post Office Box 11686
DBA Swygert & Assoc. Ltd.
A
Telephone: (803) 791-9300
Columbia, S.C. 29211
mail@
swygert-associates.com
7
STAT
E PR
OJEC
T NU
MBER
H27
-608
2-NA
THIS DRAWING AND THE
DESIGN THEREON ARE THE
PROPERTY OF SW
YGERT &
ASSOCIATES, LTD. THE
REPRODUC
TION
, COPYING, OR
USE OF THIS DRAWING
WITHOU
T THE WRITTEN
CON
SENT OF SW
YGERT &
ASSOCIATES IS PROHIBITED
AND ANY INFRINGEMENT WILL
BE SUBJECT TO LEGAL ACTION
.
BID
DOCU
MENT
S
NEW 5/8" GYP BOARD ON 1-5/8" METAL STUD FURRING
CAULK JOINT
WOOD TRIM. ABOVE -STAINED TO MATCHEXISTING WOOD
CAULK JOINT
1/2 " RIGID INSULATION
EQEQ
EQEQ
REMOVE EXISTING FAN COIL UNIT ANDWOOD TRIM & BLOCKING BELOW
EXISTING RIGID INSULATION
EXISTING ALUM. LOUVER
NEW 5/8" GWB ON 1-5/8" METAL STUDFURRING, PTD. SEEFINISH SCHEDULE.
BASE, SEE FINISH SCHEDULE
3' - 3
3/4"
1X WOOD TRIM STAINEDTO MATCH EXISTINGWOOD
3"
1-5/8" STEEL RUNNER
1-5/8" STEEL RUNNER
1/2" RIGID INSULATION
REMOVE EXISTING FAN COIL UNIT
REMOVE EXISTING WOODTRIM AND BLOCKING
EXISTING RIGID INSULATION
EXISTING ALUM. LOUVER
THREADED ROD & UNISTRUT - SEE MECH DWGS
NEW HVAC DUCT - SEE MECH DWGS
FLUSH MOUNT LIGHT FIXTURE -SEE ELEC DWGS
NEW SPRINKLER SYSTEM -SEE FIRE PROTECTION DWGSELECTRICAL CONDUIT - SEE ELEC DWGS
EXISTING STEEL ANGLE. INSTALL NEWSTEEL ANGLE ON 18TH FLOOR.
EXISTINGCONCRETE
SPANDREL BEAM
NEW PREFINISHED .080 GAUGE ALUMINUM SOFFIT -ANCHOR TO EXISTING STEEL ANGLES. SEE SPECS
NEW SUPPLY GRILL -SEE MECH. DWGS
1' - 9" F.V.
10 3/
4" F
.V.
4 1/2"
1' - 3
3/8"
2 1/2"
SEE MECH SPECS FOR THROUGH WALLDUCT PENETRATION INFORMATION
*** PRIOR TO CUTTING PENTRATIONS IN EXISTING WALLS, COORDINATEALL UTILITY PENETRATION MINIMUM DIMENSIONS AND ONLY CUT MINIMUMEXTENT OF EXISTING WALL REQUIRED. SEE MECH AND ELEC DWGS ANDSPECS FOR ADDITIONAL INFORMATION ON PENETRATION DETAILS.
EXISTING STEELANGLE. INSTALLNEW STEEL ANGLEON 18TH FLOOR.
REMOVE EXISTING METALSOFFIT, SEE DEMOLITION PLANS
EXISTINGCONCRETE
SPANDREL BEAM
DO NOT DISTURB EXISTINGSPRAY TEXTURED CEILING
EXISTING STEEL ANGLESTO REMAIN
*** PRIOR TO CUTTING PENTRATIONS IN EXISTING WALLS, COORDINATEALL UTILITY PENETRATION MINIMUM DIMENSIONS AND ONLY CUT MINIMUMEXTENT OF EXISTING WALL REQUIRED. SEE MECH AND ELEC DWGS ANDSPECS FOR ADDITIONAL INFORMATION ON PENETRATION DETAILS.
REMOVE EXISTINGUTLITIES, SEEMECHANICAL,
ELECTRICAL ANDPLUMBING
WELD 4" PIECE OF ALUM. BREAK METALTOTHE INSIDE FACE OF SOFFIT PANEL TOALLOW FOR ADJOINING PANEL ATTACHMENT
TAMPER RESISTANTSCREWS, TYP.
TAMPER RESISTANT SCREWS, TYP.
2X2X1/8 STEEL ANGLE
UNISTRUT SECURED TO CONCRETE ABOVE
.080 GAUGE ALUM. SOFFIT -ANCHOR TO STEEL ANGLES
5"
1' - 5"
FAN COIL UNITBEYOND
ELECTRICALCONDUIT. SEEELECTRICAL.
SEE DEMOLITIONPLANS ANDCOORDINATE SELECTDEMOLITION OFSPRAY TEXTUREDCEILING FOR HANGINGSUPPORTS. ETC.
THREADED ROD & UNISTRUT - SEE MECH DWGS
NEW HVAC DUCT - SEE MECH DWGS
FLUSH MOUNT LIGHT FIXTURE -SEE ELEC DWGS
NEW SPRINKLER SYSTEM -SEE FIRE PROTECTION DWGSELECTRICAL CONDUIT - SEE ELEC DWGS
NEW STEEL ANGLE
EXISTINGCONCRETE
SPANDREL BEAM
NEW PREFINISHED .080 GAUGE ALUMINUM SOFFIT -ANCHOR TO EXISTING STEEL ANGLES. SEE SPECS
NEW SUPPLY GRILL -SEE MECH. DWGS
1' - 4"
10 3/
4" F
.V.
DRAIN TUBE FROM FAN COIL UNIT
4 1/2"
1' - 3
3/8"
2 1/2" 9"
REMOVE EXISTING STEEL ANGLE & APPLYSPRAY TEXTURE ON EXISTING SMOOTH CEILING.ROOMS FL#06 ONLY. SEE NOTE 'G' ON A2.2
PROTECT EXISTING CEILING TEXTURE
WHERE DUCT PENETRATES EXISTING WALLS,ONLY CUT SHEETROCK TO EXTENTS OF DUCTAND SEAL WITH CAULK ON BOTH SIDES
*** PRIOR TO CUTTING PENTRATIONS IN EXISTING WALLS, COORDINATEALL UTILITY PENETRATION MINIMUM DIMENSIONS AND ONLY CUT MINIMUMEXTENT OF EXISTING WALL REQUIRED. SEE MECH AND ELEC DWGS ANDSPECS FOR ADDITIONAL INFORMATION ON PENETRATION DETAILS.
NEW STEEL ANGLE
REMOVE ALL EXISTING ROOF MATERIALS.FLASHING, INSULATION, MEMBRANE, ETC.
CUT OPENING 8" WIDE IN EXISTINGCONCRETE PARAPET FROM BOTTOM OFLOUVER TO 5-1/2" ABOVE ROOF SLAB.TYP. ONLY AT OVERFLOW SCUPPERS. SEEROOF DEMO PLAN ON D1.4 FOR LOCATIONS.
5 1/2"
SLOPE TOP OF OPENING TOMATCH EXISTING SLOPE
5 1/2"
8"3"
TERMINATION BAR
METAL FLASHING
CAULK TOP OF TERMINATION BAR
CANT
TAPERED RIGID INSULATION
MULTI-PLY ROOFING MEMBRANE
EXISTING CONCRETE ROOF SLAB
VARI
ES
TYP. ROOF DETAIL AROUNDENTIRE PERIMETER OF BUILDING
5 1/2"
8"3"
TERMINATION BAR
METAL FLASHING
CAULK TOP OF TERMINATION BAR
CANT
MULTI-PLY ROOFING MEMBRANE
VARI
ES
TYP. ROOF DETAIL AROUNDENTIRE PERIMETER OF PENTHOUSE
TERMINATION BAR
METAL FLASHING
TAPERED RIGID INSULATION
MULTI-PLY ROOFING MEMBRANE
EXISTING CONCRETE ROOF SLAB
CANT
BREAK METAL THROUGH WALLOVERFLOW SCUPPER, SET IN MASTIC
DRIP EDGE
REMOVE/STORE/PROTECT/AND REINSTALLEXISTING PARAPET WALL LOVERS TO ALLOWACCESS TO EXTERIOR SIDE OF WALL FOROVERFLOW SCUPPER INSTALLATION.
WRAP ROOFING MEMBRANE UPPARAPET, BEYOND
CAULK TOP OF TERMINATION BAR
MULTI-PLY ROOFING MEMBRANE
METAL FLASHING
DRIP EDGE
NEW GUTTER
TERMINATION BAR
METAL FLASHING
REMOVE/STORE/PROTECT/AND REINSTALLEXISTING PARAPET WALL LOVERS TO ALLOWACCESS TO EXTERIOR SIDE OF WALL FOROVERFLOW SCUPPER INSTALLATION.
BREAK METALTHROUGH WALL OVERFLOW SCUPPERSET IN MASTIC. PROVIDE 4" MIN. OVERLAP ON SIDESAND 8" MIN. OVERLAP AT BOTTOM AS SHOWN.
CANT
TAPERED RIGID INSULATION
MULTI-PLY ROOFING MEMBRANE
EXISTING CONCRETE ROOF SLAB
8"CAULK TOP OF TERMINATION BAR
MIN.4"
MIN.4"
REFERENCED ON: 1 1/2" = 1'-0"A3.2 A1.24 FAN COIL CALLOUT
REFERENCED ON: 1 1/2" = 1'-0"A3.2 D1.23 FAN COIL CALLOUT - DEMO
REFERENCED ON: 1 1/2" = 1'-0"A3.2 A1.22 FAN COIL SECTION
REFERENCED ON: 1 1/2" = 1'-0"A3.2 D1.21 FAN COIL SECTION - DEMO
REFERENCED ON: 1 1/2" = 1'-0"A3.2 A2.26 TYPE "B" SOFFIT SECTION
REFERENCED ON: 1 1/2" = 1'-0"A3.2 D1.25 SOFFIT - DEMO
A3.2
DETA
ILSRM
BSA
L
REFERENCED ON:A3.29 TYP. SOFFIT PANEL JOINT DETAIL
REFERENCED ON: 1 1/2" = 1'-0"A3.2 A2.28 TYPICAL PIPE ENLCOSURE DETAIL
REFERENCED ON: 1 1/2" = 1'-0"A3.2 A2.27 TYPE "A" SOFFIT SECTION
REFERENCED ON: 1 1/2" = 1'-0"A3.2 D1.411 ROOF SECTION DETAIL - DEMO
REFERENCED ON: 1 1/2" = 1'-0"A3.2 A1.412 PARAPET SECTION DETAIL
REFERENCED ON: 1 1/2" = 1'-0"A3.2 A1.413 PENTHOUSE WALL SECTION
REFERENCED ON: 1 1/2" = 1'-0"A3.2 A1.414 TYP SCUPPER SECTION DETAIL
REFERENCED ON: 1 1/2" = 1'-0"A3.2 A1.410 PENTHOUSE ROOF SECTION
REFERENCED ON:A3.215 SHEET SCUPPER AXON
REMOVE ALLEXISTING UTILITIES
1
ED
C
2 3 4
BA
1 2 3 4
UNIV
ERSI
TY O
F SO
UTH
CARO
LINA
MECH
ANIC
AL R
ENOV
ATIO
NSSO
UTH
TOW
ER
5 6 7
E
SHEET:
SHEE
T TI
TLE:
DRAW
N BY
:
D
REV.
DRAW
ING:
DESC
RIPT
ION
03/15
/12DA
TE:
PROJ
ECT
TITL
E:
C
CHEC
KED
BY:
DATE
ORIG
. BY
DRAW
N BY
5 6
Facsimile: (803) 791-0830
B
SEAL
SEAL
Swyg
ert &
Ass
ocia
tes
C O
N S
U L
T I
N G
E
N G
I N
E E
R S
Post Office Box 11686
DBA Swygert & Assoc. Ltd.
A
Telephone: (803) 791-9300
Columbia, S.C. 29211
mail@
swygert-associates.com
7
STAT
E PR
OJEC
T NU
MBER
H27
-608
2-NA
THIS DRAWING AND THE
DESIGN THEREON ARE THE
PROPERTY OF SW
YGERT &
ASSOCIATES, LTD. THE
REPRODUC
TION
, COPYING, OR
USE OF THIS DRAWING
WITHOU
T THE WRITTEN
CON
SENT OF SW
YGERT &
ASSOCIATES IS PROHIBITED
AND ANY INFRINGEMENT WILL
BE SUBJECT TO LEGAL ACTION
.
BID
DOCU
MENT
S
BASE
RB-1
RB-2
FLOORS
CPT-1
VCT-1
VCT-2
WALLS
P-1
P-2
P-3
P-4
GL
WD
ABBREVIATION DESCRIPTION MANUFACTURER, COLOR, STYLE
4" RUBBER BASE @ ROOMS
6" RUBBER BASE @ CORRIDORS
COVE BASE WITH TOE, BLACK OR LT. GREY TO MATCH EXISTING-- SEE SPEC.
COVE BASE WITH TOE, BLACK -- SEE SPEC.
CARPET TILE
VINYL COMPOSITION TILE -- ROOMS
VINYL COMPOSITION TILE -- CORRIDORS
PAINT - EGGSHELL (WALLS, TYP.)
PAINT - SEMI-GLOSS (METAL SOFFITS FLOORS 1-18)
PAINT - EGGSHELL (ACCENT COLOR)
PAINT - EGGSHELL (ACCENT COLOR)
EXISTING GLAZING
EXISTING WOOD PANELS, TO REMAIN
CEILINGS
APC-1 ACCOUSTICAL PANEL CEILING
096513
096513
096813
096519
096519
099123
099123
099123
099123
EXISTING
EXISTING
SPEC. REF.
BASIS OF DESIGN FOR PATTERN SCALE AND TEXTURE: LEES, BEAUTIFUL ABANDON, CHARACTER LINES, COLOR: TBS
12"X12", COLOR TO BE SELECTED FROM MFR. FULL RANGE, SEE SPEC.
12"X12", BASIS OF DESIGN: ARMSTRONG, EXCELON #51805 CAMEL BEIGE, OR APP'D EQ., SEE SPEC.
TO MATCH SHERWIN WILLIAMS #7626 ZURICH WHITE
TO MATCH SHERWIN WILLIAMS #7626 ZURICH WHITE
TO MATCH SHERWIN WILLIAMS #7575 CHOP STICKS OR SIMILAR VALUE, VERIFY IN FIELD
TO MATCH SHERWIN WILLIAMS #7546 PRAIRIE GRASS OR SIMILAR VALUE, VERIFY IN FIELD
N.I.C.
N.I.C.
09511 2X2 ANGLED TEGULAR, WHITE--SEE SPEC.
1. INSTALL PARTIAL RUBBER BASE AND VCT FLOORING WHERE EXISTING FLOORINGWAS DEMOLISHED AT EXISTING FAN COIL UNIT, AND WHERE BUILT IN CASEWORKREMOVED. SEE FINISH PLAN FOR EXTENT.
2. SEE REFLECTED CEILING PLANS FOR SHEET METAL SOFFITS IN RESIDENT ANDCOMMUNITY ROOMS. SHEET METAL SOFFITS TO BE PAINTED P-2. SEE SPECS.
3. SEE DEMOLITION PLANS AND FLOOR PLANS FOR PHASING AND SCOPE OF WORKIN HALL HFL#01, HFL#02, AND HFL#03. RUBBER BASE AND VCT INSTALLED IN PHASE ATO BE DEMOLISHED IN PHASE B. NEW RUBBER BASE AND CARPET TO BE INSTALLEDIN PHASE B. SEE SCHEDULE, PER PHASE.
4. ONE COAT OF PAINT TO BE APPLIED IN PHASE A. REPAINT IN PHASE B TO ACHIEVEFINISH PAINT QUALIFICATIONS, PER SPECIFICATION. RETOUCH DAMAGEDAREAS, AS NECESSARY, PRIOR TO FINAL COAT.
5. SEE DEMOLITION PLANS AND FLOOR PLANS FOR REFERENCE TO EXISTING WALLGRID ANGLES TO REMAIN. NEW GRID AND APC CEILING TO BE INSTALLED AND SETAT HEIGHT COMPATIBLE WITH EXISTING WALL ANGLES.
PHASE B WORK - NOTE TO CONTRACTORS:
1. DURING THE PROCESS OF INSTALLING HANGERS, SOFFITS, FAN COILS, METAL PAN COVERS, NEW PARTITIONS OR ANY OTHERMATERIAL OR EQUIPMENT AT THE CEILINGS OF THE EXISTING RESIDENT ROOMS ON FLOORS 2 THRU 18, THE CONTRACTORSHALL NOT COME IN CONTACT WITH THE SPRAY APPLIED TEXTURED CEILING MATERIAL THAT IS TO REMAIN IN PLACE AFTER THEPARTIAL ABATEMENT OF ASBESTOS FROM THE CEILINGS. CONTAMINATION OF THESE SPACES CAUSED BY DAMAGE TO THECEILING MATERIAL SHALL BE CLEANED UP AT THE CONTRACTOR'S EXPENSE, INCLUDING BUT NOT LIMITED TO, COSTSASSOCIATED WITH CLEARING THESE SPACES FOR RE-ACCESS, I.E. AIR SAMPLING.
2. DURING THE PROCESS OF INSTALLING UL RATED RACEWAYS AT CORRIDOR WALL PENETRATION, INSTALLATION OF NEWPARTITIONS, THE CONTRACTOR SHALL NOT DISTURB THE EXISTING GYPSUM BOARD IN ANY FASHION. NO PENETRATIONS WILLBE ALLOWED ONCE THE ASBESTOS ABATEMENT HAS BEEN COMPLETED BY THE ABATEMENT CONTRACTOR.
PHASE A WORK - NOTE TO CONTRACTORS:
1. NO PENETRATIONS OR ATTACHMENTS TO THE EXISTING GYPSUM BOARD PARTITIONS WILL BE ALLOWED ONCE THEASBESTOS ABATEMENT HAS BEEN COMPLETED BY THE ABATEMENT CONTRACTOR.
2. THE CONTRACTOR SHALL NOT COME IN CONTACT WITH THE GYPSUM BOARD MATERIAL THAT IS TO REMAIN IN PLACE AFTERTHE PARTIAL ABATEMENT OF ASBESTOS FROM THE CORRIDOR PARTITIONS ON THE EXISTING FLOORS 2 THRU 18 AND OTHERPARTITIONS ON THE BASEMENT AND GROUND LEVELS. CONTAMINATION OF THESE SPACES CAUSED BY DAMAGE TO THEGYPSUM BOARD MATERIAL SHALL BE CLEANED UP AT THE CONTRACTOR'S EXPENSE, INCLUDING BUT NOT LIMITED TO, COSTSASSOCIATED WITH CLEARING THESE SPACES FOR RE-ACCESS, I.E. AIR SAMPLING.
FINISH SCHEDULE COMMENTS
Finish ScheduleFLR LEVEL Number Name Base Finish Floor Finish NORTH EAST SOUTH WEST Ceiling Finish Comments
-- EV03 EV -- -- -- -- -- -- ---- EV01 ELEV -- -- -- -- -- -- ---- EV02 ELEV -- -- -- -- -- -- ---- EV03 ELEV -- -- -- -- -- -- ---- ST01 STAIR -- -- -- -- -- -- --BASEMENT S101 BASEMENT -- -- -- -- -- -- --GROUNDLEVEL
001 VENDING -- -- P-1 P-1 P-1 P-1 APC-1 5
GROUNDLEVEL
002 TRASH -- -- -- -- -- -- --
GROUNDLEVEL
002A TRASH -- -- -- -- -- -- --
GROUNDLEVEL
003 LIVING -- -- P-1 P-1 P-1 P-1 APC-1 5
GROUNDLEVEL
003A MECH -- -- P-1 P-1 P-1 P-1 APC-1 5
GROUNDLEVEL
003B PANTRY -- -- P-1 P-1 P-1 P-1 APC-1 5
GROUNDLEVEL
004 CHASE -- -- -- -- -- -- --
GROUNDLEVEL
005 BEDROOM -- -- P-1 P-1 P-1 P-1 APC-1 5
GROUNDLEVEL
006 TLT -- -- P-1 P-1 P-1 EXIST CT APC-1 5
GROUNDLEVEL
007 LAUNDRY -- -- P-1 P-1 P-1 P-1 APC-1 5
GROUNDLEVEL
007A LAUNDRY -- -- P-1 P-1 P-1 P-1 APC-1 5
GROUNDLEVEL
008 TLT -- -- P-1 P-1 P-1 P-1/EXIST CT APC-1 5
GROUNDLEVEL
009 CUST. -- -- -- -- -- -- --
GROUNDLEVEL
010 ELEC -- -- -- -- -- -- --
GROUNDLEVEL
011 STORAGE -- -- P-1 P-1 P-1 P-1 APC-1 5
GROUNDLEVEL
012 CUST. -- -- P-1 P-1 P-1 P-1 APC-1 5
GROUNDLEVEL
012A OFFICE -- -- P-1 P-1 P-1 P-1 APC-1 5
GROUNDLEVEL
H001 HALL -- -- P-1 P-1 P-1 P-1 APC-1 5
GROUNDLEVEL
H002 HALL -- -- P-1 P-1 P-1 P-1 APC-1 5
GROUNDLEVEL
H003 HALL -- -- P-1 P-1 P-1 P-1 APC-1 5
GROUNDLEVEL
H004 HALL -- -- P-1 P-1 P-1 P-1 APC-1 5
GROUNDLEVEL
H005 HALL -- -- P-1 P-1 P-1 P-1 APC-1 5
1 101 LOBBY -- -- P-3,GL P-3,GL P-4 WD, P-3, GL APC-1 51 101A LOBBY A -- -- P-3 P-3, GL P-3 P-4 APC-1 51 102 OFFICE -- -- P-3 P-3,GL P-3/GL P-3 APC-1 51 103 RA LIVING -- -- P-3 P-3 P-3/GL P-3 APC-1 51 103A RA BEDROOM -- -- P-3 P-3 P-3/GL P-3 APC-1 51 103B TLT -- -- P-3 P-3 P-3 P-3 EXIST1 103C CLST -- -- P-3 P-3 P-3 P-3 EXIST1 103D RA KITCHEN -- -- P-3 P-3 P-3/GL P-3 APC-1 51 104 CUST -- -- -- -- -- -- --1 104A CHASE -- -- -- -- -- -- --1 105 MEN -- --1 106 ELEC -- -- -- -- -- -- --1 107 STUDY -- -- P-3/GL P-3/GL P-3 P-3 APC-1 51 H101 HALL -- -- P-4 P-3 P-3 P-3 EXIST1 V101 VESTIBULE -- -- P-3/GL P-3 P-3/GL P-3/GL APC-1 51 V102 VESTIBULE -- -- -- P-4 -- P-3,GL EXIST2-17 FL#00 RESIDENT RB-1 VCT-1 P-1 P-1/GL P-1 P-1 EXIST, MTL 1,22-17 FL#01 RESIDENT RB-1 VCT-1 P-1 P-1/GL P-1/GL P-1 EXIST, MTL 1,22-17 FL#02 RESIDENT RB-1 VCT-1 P-1 P-1 P-1/GL P-1 EXIST, MTL 1,22-17 FL#03 RESIDENT RB-1 VCT-1 P-1 P-1 P-1/GL P-1 EXIST, MTL 1,22-17 FL#04 RESIDENT RB-1 VCT-1 P-1 P-1 P-1/GL P-1 EXIST, MTL 1,22-17 FL#05 RESIDENT RB-1 VCT-1 P-1 P-1 P-1/GL P-1/GL EXIST, MTL 1,22-17 FL#06 RESIDENT RB-1 VCT-1 P-1 P-1 P-1 P-1/GL EXIST, MTL 1,22-17 FL#07 RESIDENT RB-1 VCT-1 P-1 P-1 P-1 P-1/GL EXIST, MTL 1,22-17 FL#08 RESIDENT RB-1 VCT-1 P-1/GL P-1 P-1 P-1/GL EXIST, MTL 1,22-17 FL#09 RESIDENT RB-1 VCT-1 P-1/GL P-1 P-1 P-1 EXIST, MTL 1,22-17 FL#10 RESIDENT RB-1 VCT-1 P-1/GL P-1 P-1 P-1 EXIST, MTL 1,22-17 FL#11 RESIDENT RB-1 VCT-1 P-1/GL P-1 P-1 P-1 EXIST, MTL 1,22-17 FL#12 RESIDENT RB-1 VCT-1 P-1/GL P-1/GL P-1 P-1 EXIST, MTL 1,22-17 FL#13 COMMUNITY RB-1 VCT-1 P-1 P-1/GL P-1 P-1 EXIST, MTL 1,22-17 FL#14 CUST -- -- -- -- -- -- --2-17 FL#15 WOMEN -- -- -- -- -- -- --2-17 FL#16 ELEC -- -- -- -- -- -- --2-17 FL#17 CHASE -- -- -- -- -- -- --2-17 HFL#01 HALL RB-2(A) /RB-2(B) VCT-2 (A)/CPT-1 (B) P-1 (A)/ P-1 (B) P-1 (A)/P-1 (B) P-1 (A)/P-1 (B) P-1 (A)/ P-1,4 (B) APC-1 3,4,52-17 HFL#03 HALL RB-2(A) /RB-2(B) VCT-2 (A)/CPT-1 (B) P-1 (A)/ P-1 (B) P-1 (A)/P-1 (B) P-1 (A)/P-1 (B) P-1 (A)/ P-1 (B) APC-1 3,4,52-17 HLF#02 HALL RB-2(A) /RB-2(B) VCT-2(A)/CPT-1 (B) P-1 (A)/ P-1 (B) P-1 (A)/P-1 (B) P-1 (A)/P-1 (B) P-1 (A)/ P-1 (B) APC-1 3,4,518 1800 RESIDENT RB-1 VCT-1 P-1 P-1/GL P-1/GL P-1 EXIST, MTL 1,218 1801 RESIDENT RB-1 VCT-1 P-1 P-1 P-1/GL P-1 EXIST, MTL 1,218 1802 RESIDENT RB-1 VCT-1 P-1 P-1 P-1/GL P-1 EXIST, MTL 1,218 1803 RESIDENT RB-1 VCT-1 P-1 P-1 P-1/GL P-1 EXIST, MTL 1,218 1804 RESIDENT RB-1 VCT-1 P-1 P-1 P-1/GL P-1 EXIST, MTL 1,218 1805 RESIDENT RB-1 VCT-1 P-1 P-1 P-1/GL P-1/GL EXIST, MTL 1,218 1806 RESIDENT RB-1 VCT-1 P-1 P-1 P-1 P-1/GL EXIST, MTL 1,218 1807 RESIDENT RB-1 VCT-1 P-1 P-1 P-1 P-1/GL EXIST, MTL 1,218 1808 RESIDENT RB-1 VCT-1 P-1/GL P-1 P-1 P-1/GL EXIST, MTL 1,218 1809 RESIDENT RB-1 VCT-1 P-1/GL P-1 P-1 P-1 EXIST, MTL 1,218 1810 RESIDENT RB-1 VCT-1 P-1/GL P-1 P-1 P-1 EXIST, MTL 1,218 1811 RESIDENT RB-1 VCT-1 P-1/GL P-1 P-1 P-1 EXIST, MTL 1,218 1812 RESIDENT RB-1 VCT-1 P-1/GL P-1/GL P-1 P-1 EXIST, MTL 1,218 1813 COMMUNITY RB-1 VCT-1 P-1 P-1/GL P-1 P-1 PLAS, MTL 1,218 1814 CUST -- -- -- -- -- -- --18 1815 WOMEN -- -- -- -- -- -- --18 1816 ELEC -- -- -- -- -- -- --18 1817 CHASE -- -- -- -- -- -- --18 1820 RESIDENT RB-1 VCT-1 P-1 P-1 P-1/GL P-1/GL EXIST, MTL 1,218 H1801 HALL RB-2(A) /RB-2(B) VCT-2 (A)/CPT-1 (B) P-1 (A)/ P-1 (B) P-1 (A)/P-1 (B) P-1 (A)/P-1 (B) P-1 (A)/ P-4(B) APC-1 3,4,518 H1802 HALL RB-2(A) /RB-2(B) VCT-2 (A)/CPT-1 (B) P-1 (A)/ P-1 (B) P-1 (A)/P-1 (B) P-1 (A)/P-1 (B) P-1 (A)/ P-1 (B) APC-1 3,4,518 H1803 HALL RB-2(A) /RB-2(B) VCT-2(A)/CPT-1 (B) P-1 (A)/ P-1 (B) P-1 (A)/P-1 (B) P-1 (A)/P-1 (B) P-1 (A)/ P-1 (B) APC-1 3,4,5PH 1901 COMM. -- -- -- -- -- -- --PH 1902 ELEV SHAFT -- -- -- -- -- -- --PH 1903 ELEV EQUIP -- -- -- -- -- -- --
A8.0
FINI
SH S
CHED
ULE
RMB
SAL
1
ED
C
2 3 4
BA
1 2 3 4
UNIV
ERSI
TY O
F SO
UTH
CARO
LINA
MECH
ANIC
AL R
ENOV
ATIO
NSSO
UTH
TOW
ER
5 6 7
E
SHEET:
SHEE
T TI
TLE:
DRAW
N BY
:
D
REV.
DRAW
ING:
DESC
RIPT
ION
03/15
/12DA
TE:
PROJ
ECT
TITL
E:
C
CHEC
KED
BY:
DATE
ORIG
. BY
DRAW
N BY
5 6
Facsimile: (803) 791-0830
B
SEAL
SEAL
Swyg
ert &
Ass
ocia
tes
C O
N S
U L
T I
N G
E
N G
I N
E E
R S
Post Office Box 11686
DBA Swygert & Assoc. Ltd.
A
Telephone: (803) 791-9300
Columbia, S.C. 29211
mail@
swygert-associates.com
7
STAT
E PR
OJEC
T NU
MBER
H27
-608
2-NA
THIS DRAWING AND THE
DESIGN THEREON ARE THE
PROPERTY OF SW
YGERT &
ASSOCIATES, LTD. THE
REPRODUC
TION
, COPYING, OR
USE OF THIS DRAWING
WITHOU
T THE WRITTEN
CON
SENT OF SW
YGERT &
ASSOCIATES IS PROHIBITED
AND ANY INFRINGEMENT WILL
BE SUBJECT TO LEGAL ACTION
.
BID
DOCU
MENT
S
DN
UP
UP
DN
VESTIBULEV101
VESTIBULEV102
HALLH101
RA KITCHEN103D
RA LIVING103
RA BEDROOM103A
OFFICE102
CLST103C
TLT103B
MEN105CUST
104
CHASE104A
ELEC106
STUDY107
LOBBY101
COVEREDENTRY
5
5
5
5
P-4
P-4
LOBBY A101A
N
PHASE A WORK - NOTE TO CONTRACTORS:
1. NO PENETRATIONS OR ATTACHMENTS TO THE EXISTING GYPSUM BOARD PARTITIONS WILL BE ALLOWED ONCE THEASBESTOS ABATEMENT HAS BEEN COMPLETED BY THE ABATEMENT CONTRACTOR.
2. THE CONTRACTOR SHALL NOT COME IN CONTACT WITH THE GYPSUM BOARD MATERIAL THAT IS TO REMAIN IN PLACE AFTERTHE PARTIAL ABATEMENT OF ASBESTOS FROM THE CORRIDOR PARTITIONS ON THE EXISTING FLOORS 2 THRU 18 AND OTHERPARTITIONS ON THE BASEMENT AND GROUND LEVELS. CONTAMINATION OF THESE SPACES CAUSED BY DAMAGE TO THEGYPSUM BOARD MATERIAL SHALL BE CLEANED UP AT THE CONTRACTOR'S EXPENSE, INCLUDING BUT NOT LIMITED TO, COSTSASSOCIATED WITH CLEARING THESE SPACES FOR RE-ACCESS, I.E. AIR SAMPLING.
PHASE B WORK - NOTE TO CONTRACTORS:
1. DURING THE PROCESS OF INSTALLING HANGERS, SOFFITS, FAN COILS, METAL PAN COVERS, NEW PARTITIONS OR ANY OTHERMATERIAL OR EQUIPMENT AT THE CEILINGS OF THE EXISTING RESIDENT ROOMS ON FLOORS 2 THRU 18, THE CONTRACTORSHALL NOT COME IN CONTACT WITH THE SPRAY APPLIED TEXTURED CEILING MATERIAL THAT IS TO REMAIN IN PLACE AFTER THEPARTIAL ABATEMENT OF ASBESTOS FROM THE CEILINGS. CONTAMINATION OF THESE SPACES CAUSED BY DAMAGE TO THECEILING MATERIAL SHALL BE CLEANED UP AT THE CONTRACTOR'S EXPENSE, INCLUDING BUT NOT LIMITED TO, COSTSASSOCIATED WITH CLEARING THESE SPACES FOR RE-ACCESS, I.E. AIR SAMPLING.
2. DURING THE PROCESS OF INSTALLING UL RATED RACEWAYS AT CORRIDOR WALL PENETRATION, INSTALLATION OF NEWPARTITIONS, THE CONTRACTOR SHALL NOT DISTURB THE EXISTING GYPSUM BOARD IN ANY FASHION. NO PENETRATIONS WILLBE ALLOWED ONCE THE ASBESTOS ABATEMENT HAS BEEN COMPLETED BY THE ABATEMENT CONTRACTOR.
REFERENCED ON: 1/4" = 1'-0"A8.11 FIRST FLOOR FINISH PLAN
A8.1
FIRS
T FL
OOR
FINI
SH P
LAN
RMB
SAL
1
ED
C
2 3 4
BA
1 2 3 4
UNIV
ERSI
TY O
F SO
UTH
CARO
LINA
MECH
ANIC
AL R
ENOV
ATIO
NSSO
UTH
TOW
ER
5 6 7
E
SHEET:
SHEE
T TI
TLE:
DRAW
N BY
:
D
REV.
DRAW
ING:
DESC
RIPT
ION
03/15
/12DA
TE:
PROJ
ECT
TITL
E:
C
CHEC
KED
BY:
DATE
ORIG
. BY
DRAW
N BY
5 6
Facsimile: (803) 791-0830
B
SEAL
SEAL
Swyg
ert &
Ass
ocia
tes
C O
N S
U L
T I
N G
E
N G
I N
E E
R S
Post Office Box 11686
DBA Swygert & Assoc. Ltd.
A
Telephone: (803) 791-9300
Columbia, S.C. 29211
mail@
swygert-associates.com
7
STAT
E PR
OJEC
T NU
MBER
H27
-608
2-NA
THIS DRAWING AND THE
DESIGN THEREON ARE THE
PROPERTY OF SW
YGERT &
ASSOCIATES, LTD. THE
REPRODUC
TION
, COPYING, OR
USE OF THIS DRAWING
WITHOU
T THE WRITTEN
CON
SENT OF SW
YGERT &
ASSOCIATES IS PROHIBITED
AND ANY INFRINGEMENT WILL
BE SUBJECT TO LEGAL ACTION
.
BID
DOCU
MENT
S
UP
UPDN
DNUP
UPDN
DN
A8.23
NEW CPT, RUBBER BASE
P-4
RESIDENTFL#08
RESIDENTFL#09
RESIDENTFL#10
RESIDENTFL#11
HALLHFL#03
HALLHFL#01
RESIDENTFL#06
RESIDENTFL#05
RESIDENTFL#04
RESIDENTFL#03
RESIDENTFL#02 RESIDENT
FL#01
RESIDENTFL#00
HALLHLF#02
COMMUNITYFL#13
RESIDENTFL#12
RESIDENTFL#07
WOMENFL#15
CUSTFL#14
VCT-1
LVT - 1
CPT-1
NEW VCT, RUBBER BASE
RESIDENTFL#08
RESIDENTFL#09
RESIDENTFL#10
RESIDENTFL#11
RESIDENTFL#12
COMMUNITYFL#13
RESIDENTFL#00
RESIDENTFL#01
RESIDENTFL#02
RESIDENTFL#03
RESIDENTFL#04
RESIDENTFL#05
RESIDENTFL#06
RESIDENTFL#07
HALLHFL#01
HALLHFL#03
HALLHLF#02
WOMENFL#15
CUSTFL#14
CHASEFL#17
ELECFL#16
EXTENT OF RUBBER BASE
NEW VCT
N
PHASE B WORK - NOTE TO CONTRACTORS:
1. DURING THE PROCESS OF INSTALLING HANGERS, SOFFITS, FAN COILS, METAL PAN COVERS, NEW PARTITIONS OR ANY OTHERMATERIAL OR EQUIPMENT AT THE CEILINGS OF THE EXISTING RESIDENT ROOMS ON FLOORS 2 THRU 18, THE CONTRACTORSHALL NOT COME IN CONTACT WITH THE SPRAY APPLIED TEXTURED CEILING MATERIAL THAT IS TO REMAIN IN PLACE AFTER THEPARTIAL ABATEMENT OF ASBESTOS FROM THE CEILINGS. CONTAMINATION OF THESE SPACES CAUSED BY DAMAGE TO THECEILING MATERIAL SHALL BE CLEANED UP AT THE CONTRACTOR'S EXPENSE, INCLUDING BUT NOT LIMITED TO, COSTSASSOCIATED WITH CLEARING THESE SPACES FOR RE-ACCESS, I.E. AIR SAMPLING.
2. DURING THE PROCESS OF INSTALLING UL RATED RACEWAYS AT CORRIDOR WALL PENETRATION, INSTALLATION OF NEWPARTITIONS, THE CONTRACTOR SHALL NOT DISTURB THE EXISTING GYPSUM BOARD IN ANY FASHION. NO PENETRATIONS WILLBE ALLOWED ONCE THE ASBESTOS ABATEMENT HAS BEEN COMPLETED BY THE ABATEMENT CONTRACTOR.
PHASE A WORK - NOTE TO CONTRACTORS:
1. NO PENETRATIONS OR ATTACHMENTS TO THE EXISTING GYPSUM BOARD PARTITIONS WILL BE ALLOWED ONCE THEASBESTOS ABATEMENT HAS BEEN COMPLETED BY THE ABATEMENT CONTRACTOR.
2. THE CONTRACTOR SHALL NOT COME IN CONTACT WITH THE GYPSUM BOARD MATERIAL THAT IS TO REMAIN IN PLACE AFTERTHE PARTIAL ABATEMENT OF ASBESTOS FROM THE CORRIDOR PARTITIONS ON THE EXISTING FLOORS 2 THRU 18 AND OTHERPARTITIONS ON THE BASEMENT AND GROUND LEVELS. CONTAMINATION OF THESE SPACES CAUSED BY DAMAGE TO THEGYPSUM BOARD MATERIAL SHALL BE CLEANED UP AT THE CONTRACTOR'S EXPENSE, INCLUDING BUT NOT LIMITED TO, COSTSASSOCIATED WITH CLEARING THESE SPACES FOR RE-ACCESS, I.E. AIR SAMPLING.
REFERENCED ON: 1/4" = 1'-0"A8.21 TYPICAL FINISH PLAN - LEVEL 2-18
FINISH LEGEND
A8.2
TYPI
CAL F
INIS
H PL
AN,
LEVE
LS 2-
18
RMB
SAL
REFERENCED ON: 1/4" = 1'-0"A8.22 TYPICAL FINISH PLAN - LEVEL 2-18
PHASE A PHASE B
REFERENCED ON: 3/8" = 1'-0"A8.2 A8.23 TYPICAL ROOM FINISH PLAN