The New, Advanced Technology
Provides the Earliest, Most Discriminating
Fire Detection on the Market Today!
4
The Provides
•SAVE Your Business Without INTERRUPTION!
TIME
5
Actively Draws Air Sample Through Pipe Network
Continuous Air Sampling
6
Advantages
7
FEATURES
State-of-the-Art DetectionState-of-the-Art DetectionVirtually Immune to False Alarms
Ultra Sensitive DetectionEARLY Detection Can SAVE Your Business
New Advanced TechnologyEnsures Optimum Performance &
Reliability
New Maintenance Friendly DesignEqual or Less Requirements when
Compared to Other Air-Sampling Detectors
8
Single Point MaintenanceMinimal Impact On Business Functions
Harsh/Industrial Environment FriendlyUnaffected by Temperature, Dust or
Humidity
Remote DetectionInaccessible Spaces & High Ceiling
Applications
Small, Esthetically Pleasing Sampling Heads
Does Not Distract from Architecture or Decor
FEATURES
9
Unequalled Sampling Network EngineeringActive Detection with Accurate
ResponseNon-Ferrous Sampling Network
Does Not Effect, Nor is it Affected by Electronic Environments
Industry’s Best Pipe Network Supervision
Network Supervision Ensures Sample Integrity
Solves Security ConcernsSecure Room Access is Not Required for
Maintenance
FEATURES
10
Applications
11
Power Plants
Up to 100 FeetUp to 100 Feet
Does Not Require Multi-
Layer Protection
Does Not Require Multi-
Layer Protection
Ultra Sensitive Detection
Ultra Sensitive Detection
Will Detect TRUE Fire Threats, Even Electrical Arcing
Will Detect TRUE Fire Threats, Even Electrical Arcing
Non-Ferrous Sampling NetworkNon-Ferrous Sampling Network
Electronic Environment Friendly
Electronic Environment Friendly
Single Point Maintenance
Single Point Maintenance
Does Not Require
Access to Sampling
Heads
Does Not Require
Access to Sampling
Heads
HVDC HALL
12
Cogeneration Plants
13
Hydro GenerationFacilities
14
Hydro Generator Detection
15
Control Rooms
Single Point Maintenance
Single Point Maintenance
Minimal Disruptions to
Mission Functions
Minimal Disruptions to
Mission Functions
Ultra Sensitive Detection
Ultra Sensitive Detection
Will Detect Only TRUE Fire Threats
Will Detect Only TRUE Fire Threats
Non-Ferrous Sampling NetworkNon-Ferrous Sampling Network
Electronic Environment
Friendly
Electronic Environment
Friendly
16
Coal Conveyors
17
42
CRUSHER HOUSETEST LOCATION
Challenge:
- Determine the IFD Cirrus’ ability to detect fire over coal conveyors.
- Test the IFD Cirrus’ ability to withstand heavy coal dust environment without false alarming.
18
Installation:
- The IFD Cirrus was installed for 13 weeks in a NEMA 4 enclosure.
- From here, the piping would run down to the lower level entrance conveyors.
19
Testing:
- To conduct the test, temporary air sampling piping was constructed of ½” flexible nylon tubing running the length of the conveyor with air sampling points approx. every 10 ft.
20
Testing:
- The IFD Cirrus is outfitted with a filter manifold system that removes coal dust from the air, NOT combustion particles caused by fires.
21
Test Results:
- Despite its harsh environment, the IFD Cirrus performed flawlessly throughout the length of the test.
- It did NOT FALSE ALARM or have any troubles or faults.
22
High Bay Applications
23
High Ceilings
Up to 100 FeetUp to 100 Feet
Does Not Require Multi-
Layer Detection
Does Not Require Multi-
Layer Detection
Single Point of Maintenance
Single Point of Maintenance
Does Not Require Access
to Sampling Heads
Does Not Require Access
to Sampling Heads
Esthetically Neutral Sampling
Heads
Esthetically Neutral Sampling
Heads
Does Not Distract from
Architecture or Decor
Does Not Distract from
Architecture or Decor
24
Nuclear Facilities
25
Warehouses
Up to 100 FeetUp to 100 Feet
Does Not Require Multi-
Layer Protection
Does Not Require Multi-
Layer Protection
Single Point Maintenance
Single Point Maintenance
Inaccessible Areas
Maintenance & Operation Friendly
Inaccessible Areas
Maintenance & Operation Friendly
Does Not Require
Access to Sampling
Heads
Does Not Require
Access to Sampling
Heads
26
Air-Cooled Generators
27
Sample DirectlyFrom
Inside Equipment
28
Earliest Detection Available
29CLOUD CHAMBER
30
31
Thermal Particulate Point In Air
PVC Insulation 290Motor Oil SAE-30 310Pine Board 320Silicone Rubber 335RTV 340Acrylon Carpeting 340Wool Carpeting 360Vinyl Tile 370Polyethylene 410Nonmetallic Cable Wire Insulation 420Bond Writing Paper 500Teflon 610Polystyrene 710
MATERIAL TEMPERATURE (F°)
109/ sec/cm3 Particle Release Rate
32
Human Hair.0035 inch
.001 inch
.0001 inch
Micron
.000039 inch
(.002 Micrometers)
of a Micron
How Small Is A Micron
IFD CirrusDetects 1
500th
33
Cloud Chamber
Detects Only True Fire Threats
34
IMMUNE TO DUST
DUST PARTICLES ARE TOO LARGE!
35
Demonstration
36TIME
Laser Detector
Smoke Detector
Flame Detector
Heat Detecto
rSprinkler
Fire Growth Curve
Smoke Density
Aspirating
37
Product Features
38
PRODUCT FEATURES
Up To 4 Zones From A Single Enclosure
Up To 4 Zones From A Single Enclosure
Up To 43,200 Sq Ft Protection From A Single Panel
300 Sensitivity Levels Built-In300 Sensitivity Levels Built-In
3 Programmable Alarm Levels Per Zone
3 Programmable Alarm Levels Per Zone
3 Programmable Alarm Levels Per Zone
3 Programmable Alarm Levels Per Zone
Continuous Self Monitoring Diagnosis
Continuous Self Monitoring Diagnosis
Programmable By Key PadProgrammable By Key Pad
Fully ProgrammableFully Programmable
Easy To Read LCD DisplayEasy To Read LCD Display
Easy To Read LCD DisplayEasy To Read LCD Display
•300 Sensitivity Levels Built-In•300 Sensitivity Levels Built-In
Continuous Self Monitoring Diagnosis
Continuous Self Monitoring DiagnosisUp To 4 Zones From A Single
Enclosure
Up To 4 Zones From A Single Enclosure
39
PRODUCT FEATURES
100 Event Log100 Event Log
Optional 0-10VDC 4-20MA
Output
Optional 0-10VDC 4-20MA
Output
Common Alarm & Trouble Contacts
Common Alarm & Trouble Contacts
Alarm Data RetentionAlarm Data Retention
Common Alarm & Trouble Contacts
Common Alarm & Trouble Contacts
100 Event Log100 Event Log
Alarm Data RetentionAlarm Data Retention
2 Notification Appliance Circuits2 Notification Appliance Circuits
Optional 0-10VDC 4-20MA
Output
Optional 0-10VDC 4-20MA
Output
40
PRODUCT FEATURES
Precise Zone By Zone Flow Supervision
Precise Zone By Zone Flow Supervision
2 Notification Appliance Circuits2 Notification Appliance Circuits
Fully Engineered Multiple Head Network
Fully Engineered Multiple Head Network
Programmable On-Site Or Remotely
Programmable On-Site Or Remotely
Serial Communication InterfaceSerial Communication InterfaceSerial Communication InterfaceSerial Communication Interface
Fully Engineered Multiple Head Network
Fully Engineered Multiple Head Network
Precise Zone By Zone Flow Supervision
Precise Zone By Zone Flow Supervision
Programmable On-Site Or Remotely
Programmable On-Site Or Remotely
2 Notification Appliance Circuits2 Notification Appliance Circuits
41
CirrusNet Network Software
42
Remote Service
43
CirrusNet
Hardwire
Telephone Network
Code Operated Switch
Short Haul Modem
44
Remote Monitoring From Anywhere In The World