Transcript
  • 3111 Old Lincoln Hwy ■ Trevose, PA. 19053 Tel: 215-357-5500 ■ www.gmptools.com

    General Machine Products (KT), LLC

    GMP P/N 24065 4 Pair UTP Cat 6 Plug Terminati on Instructi ons

    Cut insulati on back about 1 1/4” Thread wires through alignment barUntwist wires and place in order

    Slide bar back to about 1/4” from endSquarely snip wires to .34” from bar

    Push wires into plug. Ensure wires bott om out in end of plug

    Slide bar back towards insulati on

    Crimp plug with GMP Modular Plug Presser with B8 Die.


Recommended