MCR 24 + BMR 80 MCR 24 + SR 130
MCR… BIC, +BMR/SR or MIHeating and domestic hot water by independent calorifier or micro-accumulated
MCR 24 :for heating only
Condensing
MCR 24 : from 6,3 to 25,3 kW, for heating only
MCR 24/28 BIC : from 6,3 to 25,1 kW, for heating
and domestic hot water preparation by integrated
calorifier
MCR… MI : from 6,3 to 35,9 kW, for heating and
instant domestic hot water production for chimney
or forced flue connection
All of these boilers are factory fitted with a control panel which can be complemented by a control system offering 2 comfort levels: • Either by room thermostat• Or by remote control according to the outside temperature with the
possibility of controlling a circuit with mixing valve in addition to a direct circuit
Various air/flue gas connection configurations are possible:we offer solutions for connection by horizontal or vertical forced flue, to a chimney, in bi-flow.
CONDITIONS OF USEBoiler:
Max. operating temperature: 90 °CMax. operating pressure: 3 barsSafety thermostat: 110 °CPower supply: 230 V/50 HzProtection index: IPX4D
BMR 80 and SR 130 DHW calorifier:Max. operating pressure primaryand secondary circuits: 10 barsMax. operating temperature primaryand secondary circuits: 95 °C
HOMOLOGATIONB23P - C13x - C33x - C53 - C43x - C63x - C83x*
GAS CATEGORYII2ESi3P, Classe NOx : 5
*to be adapted according to the country for wich the boilers are intended
All natural gasesPropane
N° d’identification CE :0063BQ3009
★★★★
VIVADENS MCRW A L L - H U N G G A S C O N D E N S I N G B O I L E R S
MCR 24MCR … MI
MCR 24/28 BIC
2
PRESENTATION
MODELS AVAILABLE
MCR 24, MCR 24/28 BIC and MCR…MI boilers are delivered fully assembled and factory tested. They come ready to operate on natural gases; operation on propane is possible by simple adjustment or by conversion kit (available as optional equipment).MCR 24 boilers are factory fitted with a heating/DHW reversal valve for connection to an independent hot water calorifier: 2 types of optional DHW calorifiers are available:- 80-litre BMR 80 calorifier to be juxtaposed to the right or left of
the boiler: version MCR 24 + BMR 80;- 130-litre SR 130 calorifier to be placed on the floor under the
boiler: version MCR 24 + SR 130.The MCR 24/28 BIC version is particularly compact (900 x 600 x 450 mm) and efficient: DHW production, with *** performance in accordance with EN 13203, is handled by a 40-litre storage calorifier integrated into the boiler, combined with an external plate exchanger with a large exchange surface, a DHW pump and a heating/DHW reversal valve.MCR .. MI boilers are mixed boilers and produce large quantities of domestic hot water (*** classification in accordance with the standard EN 13203) thanks to an oversized plate exchanger and very reactive electronics.
THEY OFFER HIGH LEVELS OF PERFORMANCE:- Efficiency at 40/30°C up to 109 %- Efficiency class ★★★★ CE- NOx < 70 mg/kWh- NOx classification: 5 in accordance with PR EN 15420- Noise level in compliance with NRA (see page 5)
STRONG POINTS
- Particularly compact, light boilers- Perfect adaptation of boiler output to actual needs thanks
to the stainless steel gas burner with complete premixing, modulating from 25 to 100% output, fitted with a silencer on the air intake.
- Stainless steel exchanger with double external envelope in composite material.
- Electronic ignition and ionisation flame check.- Delivered with a mounting frame with prefitted water and gas
valves (including the disconnector), 8-litre expansion vessel (no vessel on MCR 34/39 MI), automatic air vent. The MCR 24/28 BIC is also fitted with the 7-bar DHW safety valve and a flow collector.
- Simple, functional control panel with optional control system offering 2 comfort levels:
• By room thermostat • According to the outside temperature, with the possibility of
also controlling a direct circuit, a circuit with mixing valve by connecting a remote control with specific communication interface and the outside sensor.
- For the various air/flue gas connection options, see page 11.
Boiler ModelUseful output
heating modeat 50/30 °C (kW)
DHW modeat 80/60 °C (kW)
MC
R_Q
0001
For heating only MCR 24 6,3-25,3 –
MC
R_Q
0026
For heating and domestic hot water preparation by integrated 40-litre calorifier
MCR 24/28 BIC 6,3-25,1 6,3-27,4
MC
R_Q
0001
For heating and instant domestic hot waterproduction
MCR 24/28 MIMCR 30/35 MIMCR 34/39 MI
6,3-25,36,6-31,66,8-35,9
6,3-27,46,3-34,36,3-38,2
3
TECHNICAL SPECIFICATIONS
DESCRIPTION
Stainless steel exchangerwith low inertia and considerable resistance to corrosion with double exterior envelope in composite material used for thermal and phonic insulation
Stainless steel burnerwith total premix modulating from 25 to 100% of the output, with low NOx and CO emissions, with silencer on the air intake
Mounting frame with prefitted plumbing fixtures
Automaticair vent
Heating body and burner
Gas valve unit2-speed circulator pump
Control panel see p. 6
Expansion vessel(8 litres)
40-litre DHW storage calorifier protected by a magnesium anode
7-bar DHW safety valve
Calorifier drainage
Control panel (see p. 6)
3-bar safety valve
Plate exchanger for instant DHW (MCR…MI)
Ionisation and ignition electrodes
Expansion vessel (8 litres – initial pressure 1 bar (no vessel on MCR 34/39 MI)
Air/flue gas connection Ø 60/100 mmwith measuring point
MC
R_Q
0005
MC
R_Q
0011
MCR… MI
MCR 24/28 BIC
Heating body and burner
Air/flue gas connectionwith measuring pointAutomatic
air vent
Heating body and burner
2-speed heating circulator pump
DHWpump
Plate exchanger with large exchange surface
Mounting frame with prefitted water and gas valves (flow collector provided)
3-bar heating safety valve
MC
R_Q
0030
4
TECHNICAL SPECIFICATIONS
MAIN DIMENSIONS (IN MM AND INCHES)
670584
106
73,3
741
79,8
2642
53
2 3 5 63 44
5 6
9
132,5
328,5
379
400
160
71,5
25
300
26,5
23
17
194
670
584
106
73,3
209
680
880
741
2
10 1110
11
4 6
9
328,5
379
400
71,5
25132,5
300
444160
260Ø 427
Ø 422
176,5
32
73,36
4
2
79,81110
2 10 41162 10 4 11 6
9
972
900
50 65 65 68 66
26,5
600
128
446
21 51 456 51 21
160
584
117
670
584
10673,3
741
2
10 11
4 6
9
328,5
379
400
71,5
25 132,5
300
153110
48
305
590
Ø 570
932
446
2000
160
MCR 24MCR… MI
MCR 24 + BMR 80 (package EE 53) andConnection kit (package HG 29)
MCR 24/28 BIC
MCR 24 + SR 130 (package EE 22) andConnection kit (package HG 30)
MC
R_F0
001
MC
R_F0
002
MC
R_F0
013A
MC
R_F0
004� Heating outlet interior Ø 18 mm
� MCR 24: Primary calorifier outlet interior Ø 16 mm (1)MCR .. MI: Domestic hot water outlet interior Ø 16 mm
� Gas inlet interior Ø 18 mm� MCR 24: Primary calorifier return interior Ø 16 mm (1)
MCR .. MI: Domestic cold water inlet interior Ø 16 mm (1)� Heating return interior Ø 18 mm� Evacuation of combustion products and air inlet pipe
Ø 60/100 mm� Domestic hot water outlet
- MCR 24/28 BIC: Ø 16 mm- MCR 24 + BMR/SR: R 3/4
Domestic cold water inlet- MCR 24/28 BIC : Ø 16 mm- MCR 24 + BMR/SR: R 3/4
(1) if a DHW calorifier is connected
R: threading
* or exterior Ø 15/22 mm, dimensions to be adapted according to the country for which the boilers are intended
} *
5
TECHNICAL SPECIFICATIONS
SPECIFICATIONS TABLE
Boiler Boiler type: condensingBurner: modulating with complete premixing
Energy used: natural gas or propaneCombustion evacuation: chimney or sealedMin. flow temperature: 15 °C
Min. return temperature: noneRef. CE certificate: 0063BQ3009
Model MCR 24 MCR24/28 BIC
MCR 24 + BMR 80MCR 24 + SR 130
MCR24/28 MI
MCR30/35 MI
MCR34/39 MI
Useful output at 50/30 °C Pn (heating mode) kW 6,3-25,3 6,3-25,1 6,3-25,3 6,3-25,3 6,6-31,6 6,8-35,9Nominal output at 80/60 °C (DHW mode) kW - 27,4 - 27,4 34,3 38,2
100 % Pn at ave. temp. 70 °C % 98,3 98,3 98,3 98,3 98,2 98,0100 % Pn at return temp. 30 °C % 104,4 104,4 104,4 104,4 104,4 104,430 % Pn at return temp. 30 °C % 108,7 108,7 108,7 108,7 109,7 110,5
Nominal water output at Pn, Δt = 20 K m3/h 1,03 0,93 1,03 1,03 1,29 1,47Loss when not in use at Δt = 30 K W 30 nc. 30 30 29 28Auxiliary electrical power at Pn (without circul.) W 25 25 25 25 25 45Circulator pump output W 90 90 90 90 125 135Useful output at 80/60 °C - min/max kW 5,5-23,6 5,5-23,1 5,5-23,6 5,5-23,6 5,7-29,5 5,9-33,3Manometric height avail. heating circuit mbar > 200 > 200 > 200 > 200 > 200 > 200Water capacity l 1,7 1,8 1,7 1,8 2,0 2,2Gas flow at Pn - gas H/L m3/h 2,5/3 2,5/3 2,5/3 2,5/3 3,2/3,7 3,6/4,2(15°C, 1013 mbar) - propane kg/h 1,9 1,9 1,9 1,9 2,3 2,6Average flue gas temperature at 80/60 °C °C 78 78 78 78 74 71,5Min/max mass flue gas output kg/h 10/47 10/48 10/47 10/47 10/59 10/62Pressure available at the boiler outlet Pa 50 100 50 100 100 140Total weighted min./max. noise output in accordance with NF EN ISO 3741 dB (A) 43,1-49,3 nc. 43,1-49,3 43,1-49,3 45,0-47,9 44,1-49,5
Net weight kg 29 61 97/105 30,5 32 31,5
Specifications domestic hot water
Model MCR 24/28 BIC MCR 24 + BMR 80 MCR 24 + SR 130 MCR 24/28 MI MCR 30/35 MI MCR 34/39 MIExchanged power kW 27,4 22,6 22,6 27,4 34,3 38,2Flow over 10 min at Δt = 30 K l/10 min 180 165 200 - - -Flow over 10 min at Δt = 35 K l/h 670 555 555 - - -Spec. output at Δt = 30 K (1) l/min 18,0 16,5 20,0 14,0 17,0 19,0Min. pressure for a flow of 11 l/min bar - - - 0,4 0,4 0,4DHW losses through the outer casing at Δt = 45 K W - 73 - - -Aux. elec. output in DHW mode W 175 115 115 115 150 180Cooling constant kWh/24hl.K. - - 0,27 - - -Domestic performance at room temp. 20 °C, cold water temp. 10 °C, primary hot water temp. 85 °C(1) in accordance with EN 13203-1 for MCR 24 + BMR/SR and MCR 24/28 BIC
in accordance with EN 625 for MCR … MI
Effi ciency in % oflow calorific powerat load …% Pn and water temp. …°C
6
CONTROL PANEL
CONTROL PANEL ON MCR BOILERS
CONTROL PANEL OPTIONS
MCR boilers are fitted with a very simple control panel. This allows the continuous adaptation of “heating” and “DHW” output to needs. It incorporates functions for antifreeze protection
and cleaning the circulator pump every 25 hours and a troubleshooting assistance system with alarm code display.
“Menu” keyManometer
On/Off switch
Large LCD display
“Sweep” key
“Space” or “reset” key Maintenance key or validation key
Heating temp. adjustment key or “–” key DHW temp. adjustment key or “+” key
MC
R_Q
0004
Programmable wire-controlled room thermostat - Package AD 137Programmable wireless room thermostat - Package AD 200Non-programmable room thermostat - Package AD 140
Package AD 140
Package AD 200
The programmable thermostats handle the regulation and weekly programming of heating by activating the burner in accordance with the various operating modes: “Automatic” depending on programming, “Permanent” at a set temperature or “Holidays”. The “wireless” version is delivered
with a receiver box to be affixed to the wall close to the boiler.The non-programmable thermostat is used to regulate the room temperature according to the instruction given by activation of the burner.
8801
Q00
386
66Q
120A
MC
R_Q
0023
Easymatic communicating wire-controlled remote control - Package FM 50Easyradio communicating wireless remote control - Package AD 201To function, these remote controls must be complemented with a boiler/remote control “interface” PCB:Easymatic/Easyradio interface for connecting 1 direct circuit - Package AD 221Easymatic/Easyradio interface for connecting 1 direct circuit + 1 mixer valve circuit - Package AD 222
Package AD 201
Package AD 221
Package AD 222
These remote controls handle the regulation and weekly programming of heating by activating the burner and the circulator pump on the direct circuit or the valve circuit (if one exists) according to several operating modes: “Automatic” according
to programming, “Permanent comfort”, “Reduced permanent”, “Holidays” or “Summer”. Likewise, they handle the regulation and programming of domestic hot water.
8666
Q11
9AM
CR_
Q00
22
Outside sensor - Package AD 225The outside sensor can be used alone or in combination with room thermostats or communicating remote controls for heating regulation dependent on the outside temperature.
It is essential if using an installation with a mixing valve circuit.
MC
R_Q
0021
Domestic hot water sensor - Package AD 226
The domestic hot water sensor is used to apply priority regulation to DHW production by an independent calorifier. It is necessary, particularly
if connecting a BMR 80 or SR 130 calorifier, presented as optional equipment for these boilers.
MC
R_Q
0018
(1) For controlling a valve circuit, the connection of an outside sensor is required, see below.
7
BOILERS OPTIONS
MC
R_Q
0015
Height adjustment frame - MCR 24 et MCR… MI - Package HG 19- MCR 24/28 BIC - Package HG 75
This frame replaces the mounting frame delivered as standard with MCR boilers in order to make it possible to pass the water and gas connection
pipes behind the boiler (upwards). The plumbing fixtures are taken from the original frame and fitted to the height adjustment frame.
MC
X_F0
005
Connecting pipe kit Ø 16/18 or 15/22 mm for height adjustment frame* - Package HG 20 or HG 32This kit comprises the 5 water and gas connecting pipes to be connected to the plumbing fixtures on the MCR mounting frames to be passed behind the
top rear section of the boiler through the height adjustment frame (option above).
MC
R_Q
0006
Mounting frame with disconnector for MCR 24 - Package HG 27Mounting frame with disconnector for MCR .. MI - Package HG 33
These mounting frames are delivered as standard with the boilers concerned. However, they can be delivered in a separate package to be prefitted
and thus enable the fitter to make all the hydraulic connections in advance and install the boiler only at the last minute.
MC
R_Q
0020
Pipe cover - MCR 24 and MCR… MI - Package HG 21- MCR 24/28 BIC - Package HG 76
Provides a neat finish underneath the boiler.
MCR 24 andMCR… MI
MCR 24/28 BIC
MC
R_Q
0029
8531
Q05
0
DHW expansion vessel for MCR 24/28 BIC - Package HG 77This prevents water losses due to expansion during reheating of the domestic hot water calorifier.
Capacity: 2 litres
Condensates neutralisation calorifier - Package HC 33Wall bracket for neutralisation calorifier - Package HC 34Granule refill for neutralisation - Package HC 35
The materials used for the condensates flow pipes must be appropriate; otherwise the condensates must be neutralised. A regular check of the neutralisation system and particularly the
effectiveness of the granules by measuring the pH is necessary. If need be, the granules should be replaced.
Package HC 33
Package HC 34
8531
Q02
785
31Q
028A
MC
X_F0
010
Flow collector - Package HG 28*Used to collect the run-off from the condensates flow siphon, the safety valve and the disconnector.
*options : to be adapted according to the country for wich the boilers are intended
8
BOILER OPTIONS
INFORMATION REQUIRED FOR INSTALLATION
Propane conversion kit - Package HG 44(for all boilers except MCR 34/39 MI)Propane burner for MCR 34/39 MI - Package HG 31
To run the MCR 34/39 MI on propane, it is necessary to replace the burner fitted to the boiler with this specific burner.
For the other boilers, use the propane conversion kit or change the boiler settings.
BMR 80 domestic hot water calorifier - Package EE 53BMR 80-MCR 24 connection kit - Package HG 29SR 130 domestic hot water calorifier - Package EE 22SR 130 - MCR 24 connection kit - Package HG 30BMR 80 and SR 130 domestic hot water calorifiers are high performance calorifiers. They are protected inside by food quality standard high quartz content vitrified enamel and by a magnesium anode.The specifications of these calorifiers combined with MCR boilers are given on pages 2 and 3.
The boiler/water calorifier connection kits available include rigid and/or flexible connection pipes between the boiler and the calorifier.
MC
R_Q
0010
MC
R_Q
0016
BMR 80 HG 29
SR 130
8666
Q04
3
HG 30
8666
Q04
3
50 min.
50 min.
min. 250
min. 250
670
400
100
min
i
300
MC
R_F0
005
LOCATION
MCR condensing boilers must be installed in premises protected from frost, which can also be ventilated. The IPX4D protection index enables them to be installed in kitchens and bathrooms, excluding protection volumes 1 and 2, however.In order to ensure adequate accessibility around the boiler, we recommend that you respect the minimum dimensions given opposite.
VentilationThis must comply with prevailing regulations.
GAS CONNECTION AND ELECTRICAL CONNECTION
Comply with prevailing national or even local instructions and regulations.
9
INFORMATION REQUIRED FOR INSTALLATION
HYDRAULIC CONNECTIONSImportant: The principle of a condensing boiler is to recycle the energy contained in the water vapour in the combustion gases (latent vaporisation heat). Consequently, to achieve an annual operating efficiency in the order of 109%, it is necessary to size the heating surfaces in such a way as to obtain low return temperatures, below the dew point (e.g. underfloor heating, low temperature radiators, etc.) during the entire heating period.
MCR boilers must only be used in closed-circuit heating installations, previously cleaned to eliminate residues and deposits caused by commissioning the installation. Furthermore, it is important to protect central heating installations against the risk of corrosion, scaling and microbiological growth: the water treatment products used must comply with regulations.
Condensates dischargeThe siphon provided must be connected to the waste water discharge system. The connection must be removable and the flow of condensates visible. The connections and pipes must be in corrosion-resistant material.
An optional condensates neutralisation system is available (package HC 33 see page 7).
STANDARD INSTALLATION DIAGRAMSThe examples presented below cannot cover the full range of installation scenarios which may be encountered. Their purpose is to draw the attention to the basic rules to be followed. A certain number of control and safety devices (some of which are already integrated as standard in MCR boilers) are represented but it is ultimately up to installers, experts, consultant engineers and design departments to take the final decision on the safety and control devices to be used in the boiler room according to its specificities. In all cases, it
is necessary to abide by the codes of practice and prevailing regulations.
Attention: For the connection of domestic hot water, a sleeve made of steel, cast iron or any other insulating material must be interposed between the hot water outlet and these pipes to prevent any corrosion to the connections, if the distribution pipes are made of copper.
MCR 24, MCR 24/28 MI AND MCR 24/28 BIC :(with Grundfos UPR 15-60 type pump)
ΔT 20 °C 18 kW
Flow rate in l/h
Man
om
etr
ic h
eig
ht
in m
bar
MCR 30/35 MI, MCR 34/39 MI :(with Grundfos UPR 15-70 type pump)
ΔT 20 °C 28 kW
Flow rate in l/h
Man
om
etr
ic h
eig
ht
in m
bar
MC
R_F0
009
Manometric height of the heating circulator pump fitted to the MCR
10
STANDARD INSTALLATION DIAGRAMS
MCR 24 + BMR 80 with 1 direct circuit + 1 domestic hot water circuit, controlled by a wire-controlled programmable room thermostat + outside sensor
MCR .. MI with 1 direct circuit + 1 circuit with mixing valve, controlled by an “Easyradio” communicating wireless remote control + specific interface and outside sensor
230V
50Hz
230V
50Hz
27
32
9
9
Horloge
externe
9 2928
30
33
68
51
64
8
AD 137
27
Thermostatd'ambiance
filaire
21
Commande à distance communicante Easyradio
230V
50Hz
BUS
+
AD 201
9 9 9
64
1
1a 2a2b 1b
2
27
65
11b11b
10
°C °C °C °C
23
44
8
72
4
3
51
2928
9
68 27
AD 222
21
MC
R_F0
007
MC
R_F0
006
MCR 24/28 BIC with 1 direct “underfloor heating” circuit, controlled by a wireless room thermostat
MCR 24/28 BIC with 1 “radiator” circuit, controlled by a programmable wire connection room thermostat + outside sensor
1 Heating outlet 2 Heating return 3 3-bar heating safety valve1a Heating outlet direct circuit1b Heating outlet valve circuit2a Heating return direct circuit2b Heating return valve circuit8 Manual bleed valve9 Isolation valve10 3-way mixing valve11 Heating pump11b Heating pump for circuit with mixing valve16 Expansion vessel
21 Outside sensor23 Outlet temperature sensor after mixing valve
(delivered with PCB package FM 48)26 Domestic water load pump27 Non-return valve28 Domestic cold water inlet29 Pressure reducer30 Sealed safety device calibrated to 7 bars*32 (Optional) DHW loop pump33 DHW temperature sensor44 65 °C limiter thermostat with manual reset for
underfloor heating46 2-position 3-way directional valve50 Disconnector
51 Thermostat valve55 DHW safety valve calibrated and sealed to
7 bars64 Radiator circuit (gentle heat radiators, for
example)65 Low temperature circuit (underfloor heating, for
example)68 Condensates neutralisation system72 Hydraulic bypass75 Domestic water pump
* mandatory, in compliance with safety directives
92928
AD 200
BU
S
21
50Hz
230V
50
11/26
4616
75
355
9
65
44
27
21
50Hz
230V
11/26
4616
75
355
50
AD 137
9
51
64
8
27
92928
MC
R_F0
017A
MC
R_F0
018A
11
AIR/FLUE GAS CONNECTION
For the use of the air/flue gas connection pipes and the rules on installation, see details of the various configurations in the current
price catalogue.
4 26
2
2
1
5 312
12
12
C33xC33xB23P C33x
C33x
C33xC13x
C53
L1
L1
Lmax = L1+L2
Lmax = L1+L2
Lmax
Lmax
Lmax
Lmax
max max max 1m 1m 1m
Lmax L2
L2 Lmax
Lmax
C43x
C43x
C43x
MC
R_F0
011B
� Configuration C13x : Air/flue gas connection by means of concentric pipes to a horizontal terminal (so-called forced flue)
� Configuration C33x : Air/flue gas connec-tion by means of concentric pipes to a vertical terminal (roof outlet)or
� Air/flue gas connection using concentric pipes in the boiler room and single pipes in the chimney (combustive air with counter current in the chimney)
or� Air/flue gas connection using concentric pipes
in the boiler room and single “flex” pipes in the chimney (combustive air with counter cur-rent in the chimney)
� Configuration C53 : Separate air and flue gas connection using a bi-flow adapter and single pipes (combustive air taken from outside)
� Configuration B23P : Connection to a chimney (combustive air taken from the boiler room)
� Configuration C43x : not to be taken into consideration
Table of maximum air/flue gas pipe lengths admissible according to boiler type
Type of air/flue gas connection Maximum length of the connecting pipes in m
MCR 24 MCR 24/28 MIMCR 24/28 BIC MCR 30/35 MI MCR 34/39 MI
Concentric pipes connected to a horizontalterminal (PPS) C13x Ø 60/100 mm 6 7 4 6
Concentric pipes connected to a vertical terminal (PPS) C33x Ø 80/125 mm 31 32 22 29
Pipes - concentric in the boiler room,- single in the chimney (combustive air with
counter current) (PPS)
C33x
Ø 60/100 mmØ 80 mm 18 23,5 10 12
Ø 80/125 mmØ 80 mm - - 24 25,5
Pipes- concentric in the boiler room,- “flex” in the chimney (combustive air with
counter current) (PPS)
C33xØ 80/125 mmØ 80 mm 15,5 19 18 20
Bi-flow adapter and separate single air/flue gas pipes (combustive air taken from outside) (Alu) C53
Ø 60/100 mmsur 2x80 mm 44 48 30 32,5
In the chimney (rigid or flex) (combustive airtaken from the premises) (PPS) B23P
Ø 80 mm (rigid) 33 37 19 33
Ø 80 mm (flex) 23 27 22,5 24,5
DE DIETRICH THERMIQUES.A.S. with corporate capital of 22 487 610 d57, rue de la Gare - F - 67580 MertzwillerTél. 03 88 80 27 00 - Fax 03 88 80 27 99www.dedietrich-heating.com
DESCRIPTION
07/0
8 –
3000
1077
2 in
d. A
– 3
47.5
55.5
59 R
.C.S
Stra
sbou
rg –
Doc
umen
t not
bin
ding
. You
can
che
ck it
s va
lidity
on
the
web
site
http
:/w
ww
.ded
ietri
chth
erm
ique
.com
- Pr
inte
d in
Fra
nce
– O
TT-Im
prim
eurs
Was
selo
nne
- 823
44
VIVADENS MCR…WALL-HUNG GAS CONDENSING BOILER FOR CONNECTION TO A CHIMNEY OR A FORCED FLUE
DESCRIPTION
Brand: De DietrichClassification: **** In accordance with the european efficiency directive, NOx classification: 5Model: MCR_____ (MCR 24 for heating only, MCR..MI for
heating and production of instant DHW)MCR 24/28 BIC: (for heating and production of instant DHW
with 40 litres calorifier)Homologation: B23P-C13x-C33x-C53-C43x-C63x-C83x*Gas category: II2Esi3P* Protection index: IPX4D,Power supply: 230 V/50 HzUseful output in heating mode at 40/30 °C: _____kWUseful output in DHW mode at 80/60 °C: _____kWSpecific flow in DHW mode (MCR..MI): _____l/minSpecific flow in DHW mode (MCR 24/28 BIC): 18 l/minMax. operating temperature: 90 °CMax. operating pressure: 3 barSafety thermostat: 110 °CDimensions: 670 x 400 x 300 mmWeight empty: _____kg
- Complies with the requirements of European Directives- Stainless steel exchanger with low inertia and considerable
resistance to corrosion, with double exterior envelope in composite material used for thermal and phonic insulation
- Stainless steel burner with total premix modulating from 25 to 100% of output, with low NOx and CO emissions and a silencer on the air intake
- Control panel facilitating the ongoing adaptation of “heating” and “DHW” output to needs, which can be complemented by various options to regulate heating according to the room or outside temperature
- Fully fitted boilers: 2-speed circulating pump, 8-litre expansion vessel (except MCR 34/39 MI), automatic bleed valves, 3-bar safety valve, mounting frame with prefitted water and gas plumbing fixtures, plate exchanger for instant DHW on MCR..MI or heating/DHW reversal valve on MCR 24, air/flue gas connection in diameters of 60 to 100 mm with measuring outlet
- MCR 24/28 BIC: MCR 24 with 40-litre DHW calorifier integrated into the boiler combined with a plate exchanger, a DHW pump, a heating/DHW reversal valve. Boiler/calorifier connecting pipes and DHW sensor provided
Options for control panel- Programmable wire-controlled room thermostat- Programmable wireless room thermostat- Non programmable room thermostat- Easymatic/Easyradio interface for connecting 1 direct circuit- Easymatic/Easyradio interface for connecting 1 direct circuit +
1 mixer valve circuit- Outside sensor- Domestic hot water sensor
Boiler options- Height adjustment frame for MCR 24 and MCR ..MI- Height adjustment frame for MCR 24/28 BIC- Connecting pipe kit Ø16/18 mm or Ø15/22 mm for height
adjustment frame- Pipe cover for MCR 24 and MCR..MI- Pipe cover for MCR 24/28 BIC- DHW expansion vessel for MCR 24/28 BIC- Flow collector- Mounting frame with disconnector for MCR 24- Mounting frame with disconnector for MCR.. MI- Condensates neutralisation calorifier- Wall bracket for neutralisation calorifier- Granule refill for neutralisation- BMR 80 domestic hot water calorifier- BMR 80 – MCR 24 connecting kit- SR 130 domestic hot water calorifier- SR 130 – MCR 24 connection kit- Propane conversion kit- Propane burner for MCR 34/39 MI