Fire and Gas system
A basic understanding with our day
to day job
7/25/2019 84084810 Fire and Gas Recovered
2/32
WHY DO WE NEED FIRE & GAS PROTECTION
SYSTEM????
How it
Works
Looks?
Fire Detection /Mitigationsystems:
Fire Detection
Gas Detection
Fire Suppression systems
CO2, FM200, Deluge
Emergency Shutdown (ESD)Systems
ICSS DCS/F&G/ESD systems.
Emergency Alarm Systems
PA system
7/25/2019 84084810 Fire and Gas Recovered
3/32
Combustible Gases-Lower & Upper Limits*
Too lean for ignition Too rich for ignition
Clean Air
Combustibles
Lower
Explosive
Limit (LEL)
Upper
Explosive
Limit (UEL)
Typical Combustible
Gas Detector Range
of Measurement
50%
*No differentiation between the terms Explosive and Flammable as applied to the lower and
upper limits of flammability
7/25/2019 84084810 Fire and Gas Recovered
4/32
How does Gas Detector work?
Detect & measurevapor before
hazardous
concentration is
present
Provide outputs to
enable emergency
action24 VDC
+ -
LEL
0
0
Flammable
hydrocarbon
gas
No fault
4.0 milliamperes
7/25/2019 84084810 Fire and Gas Recovered
5/32
Types of Gas Detectors
As per operating principle:
1. Catalytic: Combustibles
2. Infrared: Combustibles
3. Electrochemical: Mainly Toxic gases (H2S,Oxygen,Cl, SO2,)
In our plant, we are having Catalytic and Infrared types, they again may bedivided into point or open path detectors
1. Pointwatch Eclipse 2. Open Path Eclipse 3. Catalytic Sensor/CGS
7/25/2019 84084810 Fire and Gas Recovered
6/32
Catalytic Sensor Operation
Combustible Gas Sensor (CGS)with DCUEX Tx
Flammable
gas
Active Element - Hot wire resistor
coated with catalytic material
Reference Element - Same as active but
without catalyst
Catalytic reaction when contact with
flammable gas generates heat &
changes Active resistance; reference
resistance unchanged
Explosion is prevented by Flame
Arrestor
Constant E or I power source required
7/25/2019 84084810 Fire and Gas Recovered
7/32
Point Infrared Detector Elements
Gas
Concentration(LEL)
IR Source LampPermeable Gas
Cell
Reference
Signal Detector
Measurement
Signal Detector
Optical Beamsplitter
Optical Filters
IR Transparent Window
Microprocessor
andElectronics
Permeable GasCellSapphire Mirror Theory of OperationThe infrared (IR) method of
gas detection relies on the IR
absorption characteristics of
gases to determine their
presence and concentration.
IR gas detectors consist of anIR light source (transmitter) and
light detector (receiver) to
measure the intensity both at
the absorption wavelength and
a non-absorbed wavelength.
If gas is present in the optical path, it will affect the intensity of
light transmitted between the light source and the detector.
This change in intensity provides the data for determining that a
specific gas, or type of gas is present.
7/25/2019 84084810 Fire and Gas Recovered
8/32
8
Open Path Gas Detector System Elements
IR Source
Microprocessor
and
Electronics
Gas
Concentration
(LEL)
Reference
Signal Detector
Measurement
Signal Detector
Optical Beamsplitter
Optical Filters
10 - 60 m
Flammable
hydrocarbon
gas
As the IR beam reaches the receiver, it passes through a focusing lens and then passes
through two narrow band IR filtersan active and a reference wavelength. The detector
computes the ratio between the two signals
The instrument's output is a function of gas concentration times the length of thesurveillance path
7/25/2019 84084810 Fire and Gas Recovered
9/32
9
Fail-Safe Operation
DirtyOpticsandCleanAir
Active Reference
IR Signal Level
HydrocarbonGas
Active Reference
IR Signal Level
CleanAir
Active Reference
IR Signal Level
Active Reference
IR Signal Level
FailedSensor
Active Reference
IR Signal Level
FailedIR-Source
Failed Microprocessor = 0 mA
7/25/2019 84084810 Fire and Gas Recovered
10/32
EQP Field Devices - Flame
UV/IR (X5200) - Single Frequency Infrared Flame Detector
UV (X2200)UV flame detector
IR (X9800) - Single Frequency Infrared Flame Detector
Multispectrum IR (X3301) -
7/25/2019 84084810 Fire and Gas Recovered
11/32
Ultraviolet Sensor Operating Principle
Anode
Cathode OiTest Source
Plastichousing
connectors(a,b,c,d)
QuartzEnvelope
Det-Tronics UV Sensor
circuit board
UV photons strike tube cathode
Cathode releases electron
Electron strikes gas molecule
Cascade effect occurs to anode
Discharge is quenched, creates pulse(count) output
Pulse output measured in CPS (countsper second)
counts/gate: # of pulses (cps) requiredto occur within one gate in order toqualify
gate length: unit of time consec. gates: # of consecutive gates
required to be satisfied before a firealarm output is provided
7/25/2019 84084810 Fire and Gas Recovered
12/32
Arc Rejection Signal Processing
7/25/2019 84084810 Fire and Gas Recovered
13/32
Analyzes the raw IR sensor signal randomness
Rejects signals that do not meet randomness criteriaNo Fire Alarm
Fire Alarm !
Signal Processing
Automatic optical integrity calibrated to
perform at all operating temperaturesInternal lamps test each sensor at the
precise wavelength once per minute
to verify operation.
7/25/2019 84084810 Fire and Gas Recovered
14/32
LOGIC & C&E SYMBOL LEGEND
CUSTOMER:
PROJECT: REVDRAWING NUMBERSIZE
B
DRAWING TITLE
CONFIDENTIAL-
THISDRAWINGANDSPECIFICATIONCONTAINPROPRIETARYINFORMATION
ANDANYREPRODUCTION,DISCLOSURE,ORUSETHEREOF IS EXPRESSLYPROHIBITEDWITHOUT WRITTENPERMISSION OF DETECTORELECTRONICSCORPORATION
SCALE:NONE DETECTOR ELECTRONICS CORPORATION6901 WEST 110TH STREETMINNEAPOLIS, MN 55438DESIGN BY:
DATE:
CHECKED
BY:
P.O.
F.O.
ONEPLACETWOPLACESTHREEPLACESFRACTIONS
ANGLES
0.00.000.000X/XXDEGREES
+/-.020+/-.010+/-.005+/-1/32+/-1
TOLERANCEUNLESSOTHERWISESPECIFIED
DESCRIPTIONDATEREV
12345678
D
C
B
A
D
C
B
A
12345678
INITIAL RELEASE03/12/01AA
XXX
Simon Pate
03/12/01
XXX
DETECTOR ELECTRONICS
EAGLE QUANTUM
Lube Oil console
Fuel Gas System
GT Exit/Entry
Enclo
sure
exha
ust
System Cabinet
RRFlextronics
Control Net
X3301
Thermals
DUCTWATCH
DCIO
Area with Detection & Suppression
7/25/2019 84084810 Fire and Gas Recovered
15/32
Fire Detector Cone of Vision
7/25/2019 84084810 Fire and Gas Recovered
16/32
How it Communicates
UV/IR Fire Detection
X5200
IR Fire
Detection
X9800
Supervised Inputs Heats,
Smokes and MACsAgent Release
PRESSHERETRYKK HERKNUS GLASSET
BREAK GLASS
BN-300BRANNALARM
Tilpasningsen het
FIREALARM
Interfaceunit
Nr.
No.
UV Fire DetectionX2200
Premier Controller
Operator Interface
Station
running S3
software
Ver 2.8
Ports
Configuration (serial port)RS-485 serial Link (Modbus RTU)
Redundant media ControlNet
OPC
option
MIR Fire Detection
X3301
24 vdc
power supply
Battery PSM
DCIO
Module
HC Gas Detection
Eclipse
Network
Extender
ARM
Signal / Audible
Devices
SAM
IDC
Supervised
Digital
inputs
Toxic Gas Detection
DCU / DCUEX
I/O Modules
Relay
AIM
IPM
7/25/2019 84084810 Fire and Gas Recovered
17/32
X3301 Multispectrum Infrared Flame Detector
Extended Cone of Vision
Combines the longest detection
range with the best false alarm
rejection capabilities
a calibrated performance test that is
automatically performed once per minute to
verify complete detector operation
capabilities. No testing with an external test
lamp is required. The detector automatically
performs the same test that a maintenance
person with a test lamp would perform
Automatic oi
Magnetic oi / Manual oi
7/25/2019 84084810 Fire and Gas Recovered
18/32
Smoke Detector
7/25/2019 84084810 Fire and Gas Recovered
19/32
Ionization Smoke Detector
7/25/2019 84084810 Fire and Gas Recovered
20/32
7/25/2019 84084810 Fire and Gas Recovered
21/32
Heat Detector
7/25/2019 84084810 Fire and Gas Recovered
22/32
Fire Detection Systems
Fusible loopSmoke detector UV/IR detector
3IR detectorThermal detector
Sprinkler
7/25/2019 84084810 Fire and Gas Recovered
23/32
Suppression Systems
TPP- EG LQ-MCC
TCPP Control Room
TCPP Deluge
ATF
Deluge
7/25/2019 84084810 Fire and Gas Recovered
24/32
Fire & Gas Panel
Mini-vesda for LQ MCC
FGP#2 - Mimic PanelFGP#1FGP#3 TCPP Mimic Panel
TPP FGP computer
Fusible loop panel
7/25/2019 84084810 Fire and Gas Recovered
25/32
Alarms
Platform Emergency AlarmAbandon Platform Alarm
Extinguishing Gas to be Released alarm
7/25/2019 84084810 Fire and Gas Recovered
26/32
Emergency Manual operation
7/25/2019 84084810 Fire and Gas Recovered
27/32
Enclosed Area Protection
7/25/2019 84084810 Fire and Gas Recovered
28/32
Manual Release
7/25/2019 84084810 Fire and Gas Recovered
29/32
Manual Release
7/25/2019 84084810 Fire and Gas Recovered
30/32
FM-200 Bank
7/25/2019 84084810 Fire and Gas Recovered
31/32
Emergency Beckons
7/25/2019 84084810 Fire and Gas Recovered
32/32