KS Klima-ServiceOur aim and mission is to manufacture products that protect human health and meet prescribed parameters of European and international standards and the strictest ecological and environmental regulations.
In 1993, Jirí and Liana Beseda have founded the KS Klima-Service Company that became an exclusive rep-resentative of the German company KS Klima-Service GmbH. It started to import air filters for the Czech and Slovak markets.
In 1995, the company began its own production, first of simple filters and then of technologically more compli-cated pocket filters, activated carbon filters and highly efficient HEPA filters. In order to increase its credibility and to win important orders, the KS Klima-Service a.s. joint stock company is founded in 1997.
The joint stock company KS Klima-Service has become one of the leaders in the field of atmospheric and sorption filtration on the Central and Eastern European markets. By integrating new production technologies and extend-ing our development and production base, we bring to the market new and unique products. We want to increase substantially export of our products to the EU countries as well as to other Central and Eastern European countries. We want to boost our position of a leader in terms of tech-nology, quality, customer care, development and produc-tion of new products in the field of atmospheric filtration.
MissionThrough its modern and responsible way of manage-ment, the KS Klima-Service joint stock company intends to provide to its customers the best services in the field of development, production and deliveries of air filters and filtration equipment.
Ing. Jiří Beseda
KS Klima-Service production facilities, Námestí Svobody square and Prachanda in Dobríš
CONTENTSClassification of air filters 4Basic overview of KS Klima-Service products 5Filtration – classification of filters 6Legend 8
Filter media 9KS PPI 10/6 and PPI 10/10 10KS H 640 11KS 15/100 and KS 15/150 12KS B/220 and KS B/290 13KS 15/350 and KS 15/500 14KS A/300 and KS A/500 15KS A/560 G 16KS A/560 G10 – Viledon 17KS Glas 1“ and KS Glas 2“ 18KS Glas C and Glas 300 19KS PA Grün 2“, KS PA Grün 3“, KS PA Grün 4“ 20Filter media VS LAK 21KS AFVH – floor pre-filter 22
Kapsové filtry 23KS PAK 85 E, F7 24KS PAK 25 and KS PAK 35 25KS PAK 45 and KS PAK 55 26KS PAK 62 27KS PAK 85 28KS PAK 95 29KS PAK 98 30KS PAK 45 and KS PAK 62 – glass fibre 31KS PAK 85 – glass fibre 32KS PAK 95 and KS PAK 98 – glass fibre 33KS PAK AST/2 and KS PAK AST 34KS PAK SAM-G4 and KS PAK SAM-M5 35KS PAK DR-G3 36KS PAK DR-G4 37KS PAK 35 L 38
Pocket filters 39KS Z1/2“, KS Z1“ and KS Z2“ 40KS PR-100 41KS PR NEW 42KS PL-25 43KS PL-5 44KS PL-10 and KS PL-20 45KS PL-F 46KS W 50, G4; KS W 100, G4 and KS W 150, G4 47KS W 50, M5; KS W 100, M5 and KS W 150, M5 48KS W 50, M6 49KS W 50, F7 50KS MPP 96/5 51KS MPP 96/6 and KS MPP 96/7 52KS MPP 96/8 53
KS MPP 96/9 54KS MA 12,5, KS MA 20, KS MA 25 and KS MA 45 55KS GTA 200 and KS GTA 300 56MACROFALT and MACROPAC 57
Compact filters 58KS FP M6-F9 59KS FP V3 60KS FP E10-H13 61TMP elements for gas turbines M6-F7 62TMP, TMPC elements for gas turbines F8-E10 63
Absolute filters for microparticles 64KS BESTFIL (HEPA) 65Ultrafilter CR 66Ultrafilter N 67JP and JK 68JG and JKG 69Filter inserts – industrial filtration 70
Components for clean rooms 71CG inlet pressure ceilings with laminar flow 72KS extensions for clean rooms 73
Filter units for air handling pipelines 74Filter units KS BK 75Special filter units with multi-stage filtration 76KS NICE AIR 77Filter units NG 78Two-phase combination of filters M6-F9 79
Mounting frames 80Mounting frames KS RA 81Mounting frames KS RS 120 82
Adsorption filters with activated carbon 83KS KOPA and KS KOPA-BIG 84KS BD 85KS BD BIG 86Desulphurisation unit SULOFF 87AFP 88Panel filter KS WA 89PL-CARB 90Non-impregnated activated carbon 91Impregnated activated carbon 92
Accessories 93Pressure gauges for pressure loss measurement 94
Environmental profile 96Production, research and development 97References 99
4
EN 779 Mean separation efficiency (Am)
of synthetic dust (%)
Mean efficiency (Em)
for 0.4 μm particles (%)
Minimum efficiency
[M.E. for 0.4 μm particles (%)]Filter group Filtration class
Coarse dust
G1 50 < Am < 65 – –
G2 65 < Am < 80 – –
G3 80 < Am < 90 – –
G4 90 < Am – –
Semi-coarse dust
M5 – 40 < Em < 60 –
M6 – 60 < Em < 80 –
Fine dust
F7 – 80 < Em < 90 35
F8 – 90 < Em < 95 55
F9 – 95 < Em 70
EN 1822 Total value for MPPS particles (0.1 – 0.3 μm) Integral value for MPPS particles (0.1 – 0.3 μm)
Filter group Filtration class Efficiency (%) Penetration (%) Efficiency (%) Penetration (%)
Group E
EPA
E 10 85 15 – –
E 11 95 5 – –
E 12 99.5 0.5 – –
Group H
HEPA
H 13 99.95 0.05 99.75 0.25
H 14 99.995 0.005 99.975 0.025
Group U
ULPA
U 15 99.999 5 0.000 5 99.997 5 0.002 5
U 16 99.999 95 0.000 05 99.999 75 0.000 25
U 17 99.999 995 0.000 005 99.999 9 0.0001
New international classification of air filtersaccording to CSN EN 779:2012 and CSN EN 1822:2010
5
Filter media• Polyurethane• Natural latex fibre• Synthetic fibre• Glass fibre
Filters for ventilation, air-handling and air-conditioning• Pocket filters• Special pocket filters• Frame filters• Compact filter elements
EPA, HEPA, ULPA filters• Compact filters• Absolute filters for microparticles• Components for clean rooms
Adsorption filters for separation of gaseous harmful substances and odours• Adsorption filters with activated carbon
Re-activation of activated carbon• We provide complete servicing of all systems with
activated carbon
Special filtration equipment and accessories• Filter units for pipelines• Accessories – mounting frames• Special filter units with multi-stage filtration• Pressure gauges• Filters for industrial filtration
ProductsBasic overview of KS Klima-Service products
6 FILTRAČNÍ TECHNIKATřídění filtrů do filtračních skupin
Filter group Filtration class Examples of separated
particles material
Recommendation for application of air filters KS filter type
GFilters for coarse
dust particlesEfficient for particles >− 10 μm
ČSN EN 779:2012
Filters with mean
efficiency lower than 40 %
for 0.4 μm particles.
G1G2
• Leaves
• Insects
• Textile fibres
• Sand
• Flying ash
• Water drops
• Hair
• Only for the simplest applications (e.g. as protection against insects).
• KS PL
• KS GLAS Z
• KS PR
• KS PR NEW
• KS MA
• KS BK
• Filter media
G3G4
• Flower pollen
• Pollen
• Fog
• Waste air from painting boxes and kitchens
• Protection against pollution for air conditioning and compact instruments (e.g. window air conditioning, fans)
• Pre-filters for filtration classes F7 to F8 (necessary only in case of heavy polluted input air)
• Pre filters and circulation filters for civil protection equipment
• KS PAK 25, 35
• KS GLAS Z
• KS W
• KS GT
• KS PR
• KS PR NEW
• KS PL
• Filter media
• KS MA
• KS BK
M, FFilters for fine dust particles
Efficient for particles >− 1 μm
ČSN EN 779:2012
Filters with mean
efficiency from 40 % to 80 %
for 0.4 μm particles.
M5 • Spores
• Cement dust
• Particles causing stains or dust sedimentation
• Entering outside air filters for the areas with the lowest demands (e.g. workshops, storages, garages)
• Filtration class F8 and F9 pre-filters
• KS PAK 45, 55
• KS W
• KS PR NEW
• KS PAK AST
• Filter media
• KS BK
M6 • Larger bacteria
• Germs on carrying particles
• Inlet filters for low demand areas (e.g. sales areas, some production areas)
• Filtration class F9 and E10 pre-filters
• Outlet air filters before heat exchangers
• KS PAK 62
• KS W, KS MPP
• KS FP
• KS GT
• KS BK
• TMP
F7F8
• Accumulated carbon black
• Dust passing through lungs
• PM 2,5 - dust
• Cement dust (fine fraction)
• Circulating air filters in ventilation units
• After-filters in air-conditioning units for medium demands, e.g. department stores, offices and some production areas
• Filtration class E11 and E12 pre-filters
• KS PAK 85, 95
• KS W, KS MPP
• KS FP
• KS GLAS C
• N
• KS BK
• TMP
F8F9
• Tobacco smoke (coarse fractions)
• Metal oxides smoke (coarse fractions)
• Oil smoke
• Bacteria
• After-filters in air-conditioning units for higher demands, e.g. offices, production areas, distribution centres, laboratories
• Outside air equipment in hospitals
• Computer machinery centres
• Filtration class H13, H14 pre-filters
• Pre-filters for adsorption filters (e.g. activated carbon filters)
• Pre-filters for pharmaceutical industry (mind certification regulations)
• KS PAK 95, 98
• JP-Blue
• KS FP
• hepatex PB - Blue
• Ultrafiltr N
• KS FP-P
• KS BK
• KS MPP
• TMP
7
Filter group Filtration class Examples of separated
particles material
Recommendation for application of air filters KS filter type
E, HFilters for
microparticlesEfficient for
particles >− 0.01 μm
ČSN EN 1822:2010
Efficiency for MPPS particles
(0.1 - 0.3 μm) 85 - 99.95%
E10E11
• Germs
• Tobacco smoke
• Metal oxides smoke
• Viruses on carrying particles
• Soot
• After-filters for high demands areas (e.g. laboratories and hospitals)
• After-filters for “clean rooms” classes >− ISO 7 in pharmaceutical, food processing, optical and light engineering industries
• N, CR ultrafilter
• TMP
• NG, KS BESTFIL
• Hepatex PB - Red
• Hepatex PB - Yellow
• KS extensions for clean rooms
E12H13
• Oil smoke in the stage of formation
• Aerosol - microparticles
• Radioactive aerosol
• Sea salt evaporation vapours
• After-filters for hospitals with higher demands, however without the leakage test prescription
• After-filters for food processing, electronics, pharmaceutical and film industries
• Outlet air filters for nuclear industry equipment
• After-filters for “clean rooms” classes >− ISO 5
• After-filters in civil protection equipment
• KS FP
• CR, NG
• Hepatex PB - yellow, galss
• KS BESTFIL
• Ultrafilter N
• KS extensions for clean rooms
H14 • Aerosol - microparticles
• Viruses
• After-filters for “clean rooms” classes >− IS0 3
• After-filters for “clean rooms” classes >− IS0 2
• After-filters for “clean rooms” classes >− IS0 1
• CR, CRM
• N, NG
• KS extensions for clean rooms
UFilters for
microparticlesČSN EN 1822:2010
Efficiency for MPPS particles
(0.1 - 0.3 μm)
99.999 5 - 99.999 995%
U15U16U17
• Aerosol - microparticles • After-filters for “clean rooms” classes >− IS0 3
• After-filters for “clean rooms” classes >− IS0 2
• After-filters for “clean rooms” classes >− IS0 1
• CR, CRM
• N, NG, JM
AFilters with
activated carbonNot standardised
Activated carbon (non-impregnated)
• Light volatile hydrocarbons VOC’S
• Bitumen, tar, petrol and kerosene vapours
• Vapours from solvents
• Body, civilizational and hospital odours
• Food, kitchen and putrid odours
• Separation of odours in the airports, office and administration buildings, hotels, hospitals
• IAQ improvement
• SBS (sick building syndrome) improvement
• Filtration of inlet air in microelectronics
• Elimination of harmful gases from circulating air
• KS AFP-AZ
• KS BD
• KS KOPA
• KS AFP-AZ DUO
• KS NICE air
• KS BD BIG
• KS KOPA BIG
• KS WA
Filtersfor gas absorption
Not standardised
Impregnated activated carbon,
polymers
• Acidic trace gases
• SO2, S04, NO2, NOx
• HCl, H2SO4, H2S, HF, Cl2• Amines
• NH3, NH4
• NMP, HMDS
• Inlet air filtration for control centres and computer rooms (e.g. in airports)
• Filters of inlet and circulating air for distribution centres and control rooms in corrosive environments
• Inlet and circulating air filters for microelectronics
• Inlet and circulating air filters for museums, historical archives and libraries
• Circulating air filtration in microelectronics
• KS AFP-AS
• KS BD
• KS KOPA
• KS AFP-AA
• KS BD BIG
• KS KOPA BIG
8 LEGEND
Pharmaceutical industry, clean rooms Areas with the highest demands for cleanliness: hospitals, pharmaceutical drugs production plants, medical research establish-ments, pharmaceutical industry, electrotechni-cal industry, research institutes.
Industry A filter meeting requirements on suppression of atmospheric dust and harmful odours in industrial facilities – food process-ing, automotive industry, chemical industry, mechanical engineering.
PLUS service A complete servicing and maintenance of air-handling equipment is pro-vided as part of delivery.
HVAC Heating, ventilation and air-condi-tioning. A full line of high quality air filters pro-vides optimum ventilation of working, living, commercial and office areas.
High efficiency A highly efficient filter for separation of dust particles, aerosols, oil mist or odours and gases.
Low energy demand A highly effi-cient filter for separation of dust particles, aer-osols, oil mist or odours and gases.
Hygienically harmless Hygienic as-sessment by the National Institute of Public Health of the Czech Republic.
Food processing Use in food process-ing industry – dairies, cheese production, meat processing, beverage industry.
9
Filter media from polyurethane are highly resistant to humidity and fully renewable. The structure of the KS PPI filter media (soft foamy matter) is resistant to stress and facilitates exceptionally high air in-take flow rates at low pressure losses.
The filter media from natural latex fibre H640 are designed for filtering coarse dust particles. They are supplied in the thick-ness of 20, 30 and 40 mm. They are used especially in the food processing industry and medicine.
Filter media from synthetic fibre consist of randomly arranged twisted non-woven fibres of varying thickness, reinforced with a plastic binder (or thermally) into a solid and stable filter fleece. They are used as pre-filters or 1st stage filters in air-condi-tioning and ventilation units. They are used for filtering coarse and fine dust particles.
Glass fibre media consist of elastic, twisted, randomly arranged glass fibres fixed with a special plastic in the point of contact. As the thickness of the fibre decreases, the filter media gets thicker and finer on the clean air side. This is to achieve a high degree of separation and huge dust accumulation ability. Some media are saturated with a non-harmful dust binding agent in order to achieve better binding and separa-tion of particles.
Floor filters from recycled paper pfor separation of paint drops during spraying. The Venturi effect combined with changes in flow of air containing paint particles provide a highly efficient protection. All types consist of two fanfold cardboards. Openings in the front panel are placed asymmetrically against openings in the back panel. When air is passing through the filter, the flow changes in all the three axes. Separated liquid particles are isolated in pockets formed in the back panel with deeper “V” folds. They are used independently or as pre-filters in multi-stage filtration systems of exhaust equipment in paint shops.
A wide range of special filter media from polyure-thane, natural latex fibres, synthetic and glass fibres for pre-filtration and main filtration in air-handling and air-conditioning units. The filter media are supplied in rolls or cut as required.
FILTER MEDIA
10
As
part
of o
ur p
rogr
amm
e of
con
tinuo
us im
prov
emen
t, K
S K
lima-
Serv
ice,
a.s
. re
serv
es th
e rig
ht to
cha
nge
the
spec
ifica
tion
with
out p
rior n
otic
e. 0
2/2
014
KS PPI 10/6 and PPI 10/10Filter media – polyurethane
Filtration class according to EN 779:2012
G1Delivery options
cut-to-size and sheetsPossibility of regeneration
yes
Pre
ssur
e lo
ss [P
a]
100
80
60
40
20
0 1 000 2 000 3 000 4 000
Volume flow rate [m3/h/m2]
Technical data Unit of measure PPI 10/6 PPI 10/10
Filtration class according to EN 779:2012 – G1 G1
Mean separation (Am) according to EN 779:2012 % > 50 > 50
Nominal air flow rate m3/h/m2 3,400 3,400
Initial pressure loss at nominal load Pa 20 25
Recommended final pressure loss Pa 250 250
Maximum thermal resistance ˚C 100 100
Filter propertiesThe medium is highly resistant to humidity and fully regenerable. The structure of the PPI is resistant to stress and facilitates exceptionally high air intake flow rates at low pressure losses. PPI media are reticulated polyester-based PU foams. The network structure is fully open and does not contain any closed cells. This is achieved during the thermal reticulation process (netting, meshing, cracking, corrugation) when all the cell membranes left after foaming break and merge with cell lamellas.
Types of PPI:• foam of medium strength when compressed • foam of higher strength when compressed • foam with better fire resistance conforming to the
MVSS 302 standard• PPI 30 • PPI 45 • PPI 60 as required
Field of applicationThey are used as pre-filters or 1st stage filters in airconditioning and ventilation units.
MaterialPolyurethane
Waste disposalLandfilling or incineration in authorised incineration plants.
Pressure loss diagram PPI 10/6 PPI 10/10
11KS H 640Filter media – natural latex fibre
Filtration class according to EN 779:2012
G3Delivery options
cut sizesPossibility of regeneration
yes – partially
Pressure loss diagram H 640
Pre
ssur
e lo
ss [P
a]
100
80
60
40
20
0 1 000 2 000 3 000 4 000
Volume flow rate [m3/h/m2]
Filter propertiesFilter medium from natural latex fibres for filtration of coarse dust particles. Supplied in thicknesses of 20, 30 and 40 mm.
Field of applicationUsed especially in food processing, dairy production and medicine.
MaterialNatural latex fibre.
Waste disposalLandfilling or incineration in authorised incineration plants.
Technical data Unit of measure H 640
Filtration class according to EN 779:2012 – G3
Mean separation (Am) according to EN 779:2012 % 80 – 90
Nominal air flow rate m3/h/m2 3,400
Initial pressure loss at nominal load Pa 35
Recommended final pressure loss Pa 400
Maximum thermal resistance ˚C 60
FILT
ER
ME
DIA
PO
CK
ET
FILT
ERS
FRA
ME
FILT
ERS
CO
MPA
CT
FILT
ERS
AB
SOLU
TE F
ILTE
RS
FOR
MIC
RO
PAR
TIC
LES
CO
MP
ON
ENTS
FO
R
CLE
AN
RO
OM
SFI
LTER
UN
ITS
FOR
AIR
H
AN
DLI
NG
PIP
ELIN
ES
MO
UN
TIN
G F
RA
ME
SA
DSO
RP
TIO
N F
ILTE
RS
WIT
H A
CTI
VATE
D C
AR
BO
NA
CC
ES
SOR
IES
12
As
part
of o
ur p
rogr
amm
e of
con
tinuo
us im
prov
emen
t, K
S K
lima-
Serv
ice,
a.s
. re
serv
es th
e rig
ht to
cha
nge
the
spec
ifica
tion
with
out p
rior n
otic
e. 0
2/2
014
KS 15/100 and KS 15/150Filter media – synthetic fibres
Filtration class according to EN 779:2012
G2Delivery options
rolls, cut sizesPossibility of regeneration
no
Pressure loss diagram 15/100 15/150
Filter propertiesThe new synthetic filter media consist of randomly arranged twisted non-woven fibres of varying thickness, reinforced with a plastic binder (or thermally) into a solid and stable filter fleece with progressive thickening on outlet side.
Field of applicationThey are used as pre-filters or 1st stage filters in airconditioning and ventilation units. They are used for filtering coarse dust particles.
MaterialSynthetic fibre
Waste disposalLandfilling or incineration in authorised incineration plants.
Technical data Unit of measure 15/100 15/150
Filtration class according to EN 779:2012 – G2 G2
Mean separation (Am) according to EN 779:2012 % 65 – 80 65 – 80
Nominal air flow rate m3/h/m2 3,400 3,400
Initial pressure loss at nominal load Pa 23 25
Recommended final pressure loss Pa 250 250
Maximum thermal resistance ˚C 90 100
Pre
ssur
e lo
ss [P
a]
100
80
60
40
20
0 1 000 2 000 3 000 4 000
Volume flow rate [m3/h/m2]
13KS B/220 and KS B/290Filter media – synthetic fibres
Filtration class according to EN 779:2012
G3, G4Delivery options
rolls, cut-to-sizePossibility of regeneration
no
Pressure loss diagram B/220 B/290
Filter propertiesThe filter media consist of randomly arranged twisted non-woven fibres of varying thickness, reinforced with a plastic binder (or thermally) into a solid and stable filter fleece with progressive thickening on outlet side. Due to a progressive structure of fibres, the materials offer an extremely low pressure loss and high dust accumulation capacity.
Field of applicationThey are used as pre-filters or 1st stage filters in airconditioning and ventilation units.
MaterialSynthetic fibre
Waste disposalLandfilling or incineration in authorised incineration plants.
Technical data Unit of measure B/220 B/290
Filtration class according to EN 779:2012 – G3 G4
Mean separation (Am) according to EN 779:2012 % 80 – 90 > 90
Nominal air flow rate m3/h/m2 3,400 3,400
Initial pressure loss at nominal load Pa 22 35
Recommended final pressure loss Pa 250 250
Maximum thermal resistance ˚C 90 90
Pre
ssur
e lo
ss [P
a]
100
80
60
40
20
0 1,000 2,000 3,000 4,000
Volume flow rate [m3/h/m2]
FILT
ER
ME
DIA
PO
CK
ET
FILT
ERS
FRA
ME
FILT
ERS
CO
MPA
CT
FILT
ERS
AB
SOLU
TE F
ILTE
RS
FOR
MIC
RO
PAR
TIC
LES
CO
MP
ON
ENTS
FO
R
CLE
AN
RO
OM
SFI
LTER
UN
ITS
FOR
AIR
H
AN
DLI
NG
PIP
ELIN
ES
MO
UN
TIN
G F
RA
ME
SA
DSO
RP
TIO
N F
ILTE
RS
WIT
H A
CTI
VATE
D C
AR
BO
NA
CC
ES
SOR
IES
14
As
part
of o
ur p
rogr
amm
e of
con
tinuo
us im
prov
emen
t, K
S K
lima-
Serv
ice,
a.s
. re
serv
es th
e rig
ht to
cha
nge
the
spec
ifica
tion
with
out p
rior n
otic
e. 0
2/2
014
KS 15/350 and KS 15/500Filter media – synthetic fibres
Filtration class according to EN 779:2012
G3, G4Delivery options
rolls, cut sizesPossibility of regeneration
no
Pressure loss diagram 15/350 15/500
Filter propertiesThe filter media consist of randomly arranged twisted non-woven fibres of varying thickness, reinforced with a plastic binder (or thermally) into a solid and stable filter fleece with progressive thickening on outlet side. Due to a progressive structure of fibres, the materials offer an extremely low pressure loss and high dust accumulation capacity.
Field of applicationThey are used as pre-filters or 1st stage filters in airconditioning and ventilation units.
MaterialSynthetic fibre
Waste disposalLandfilling or incineration in authorised incineration plants.
Technical data Unit of measure 15/350 15/500
Filtration class according to EN 779:2012 – G3 G4
Mean separation (Am) according to EN 779:2012 % 80 – 90 > 90
Nominal air flow rate m3/h/m2 3,400 3,400
Initial pressure loss at nominal load Pa 35 50
Recommended final pressure loss Pa 250 250
Maximum thermal resistance ˚C 90 90
Pre
ssur
e lo
ss [P
a]
100
80
60
40
20
0 1 000 2 000 3 000 4 000
Volume flow rate [m3/h/m2]
15KS A/300 and KS A/500Filter media – synthetic fibres
Filtration class according to EN 779:2012
M5Delivery options
rolls, cut sizesPossibility of regeneration
no
Pressure loss diagram A/300 A/500
Filter propertiesFilter medium from synthetic fibres of varying thickness, thermally treated and reinforced with a dust binding agent. Thickening of fibres towards the outlet side enables efficient use of the entire thickness for capturing of dust.
Field of applicationThey are used as pre-filters or 1st stage filters in airconditioning and ventilation units and as ceiling filters in painting and spraying boxes.
MaterialSynthetic fibre
Waste disposalLandfilling or incineration in authorised incineration plants.
Technical data Unit of measure A/300 A/500
Filtration class according to EN 779:2012 – M5 M5
Mean efficiency (Em) for 0.4 μm particles
according to EN 779:2012% 40 – 60 40 – 60
Nominal air flow rate m3/h/m2 2,500 2,500
Initial pressure loss at nominal load Pa 60 70
Recommended final pressure loss Pa 450 450
Maximum thermal resistance ˚C 100 100
Pre
ssur
e lo
ss [P
a]
100
80
60
40
20
0 1 500 2 500Volume flow rate [m3/h/m2]
FILT
ER
ME
DIA
PO
CK
ET
FILT
ERS
FRA
ME
FILT
ERS
CO
MPA
CT
FILT
ERS
AB
SOLU
TE F
ILTE
RS
FOR
MIC
RO
PAR
TIC
LES
CO
MP
ON
ENTS
FO
R
CLE
AN
RO
OM
SFI
LTER
UN
ITS
FOR
AIR
H
AN
DLI
NG
PIP
ELIN
ES
MO
UN
TIN
G F
RA
ME
SA
DSO
RP
TIO
N F
ILTE
RS
WIT
H A
CTI
VATE
D C
AR
BO
NA
CC
ES
SOR
IES
16
As
part
of o
ur p
rogr
amm
e of
con
tinuo
us im
prov
emen
t, K
S K
lima-
Serv
ice,
a.s
. re
serv
es th
e rig
ht to
cha
nge
the
spec
ifica
tion
with
out p
rior n
otic
e. 0
2/2
014
KS A/560 GFilter media – synthetic fibres, ceiling filter
Filtration class according to EN 779:2012
M5Delivery options
rolls, cut-to-sizePossibility of regeneration
no
Pressure loss diagram A/560 G
Filter propertiesThe special fine filter media are made from progressively thickening synthetic fibres reinforced with a plastic binder (or thermally) into a solid and stable filter fleece with progressive thickening towards the outlet side. They are fixed by a special protective plastic grid on the clean air side. The material is filled with a dust binding agent.
Field of applicationThey are used as ceiling filters in painting and spraying boxes with the highest demands for cleanliness without releasing fibres.
MaterialSynthetic fibre
Waste disposalLandfilling or incineration in authorised incineration plants.
Technical data Unit of measure A/560G
Filtration class according to EN 779:2012 – M5
Mean efficiency (Em) for 0.4 μm particles
according to EN 779:2012% 40 – 60
Nominal air flow rate m3/h/m2 2,500
Initial pressure loss at nominal load Pa 110
Recommended final pressure loss Pa 450
Maximum thermal resistance ˚C 90
Pre
ssur
e lo
ss [P
a]
150
120
90
60
30
0 1,500 2,500Volume flow rate [m3/h/m2]
17KS A/560 G10 – ViledonFilter media – synthetic fibres, ceiling filter
Filtration class according to EN 779:2012
M5Delivery options
rolls, cut sizesPossibility of regeneration
no
Pressure loss diagram A/560 G10
Filter propertiesThe special fine filter media of the highest quality are made from progressively thickened synthetic fibres reinforced with a plastic binder (or thermally) into a solid and stable filter fleece with progressive thickening towards the outlet side. The material is filled with a dust binding agent. The medium is fixed with a protective plastic grid preventing release of fibres from the medium.
Field of applicationThey are used as ceiling filters in painting and spraying boxes with the highest demands for cleanliness without releasing fibres.
MaterialSynthetic fibre
Waste disposalLandfilling or incineration in authorised incineration plants.
Technical data Unit of measure A/560 G10 – Viledon
Filtration class according to EN 779:2012 – M5
Mean efficiency (Em) for 0.4 μm particles
according to EN 779:2012% 40 – 60
Nominal air flow rate m3/h/m2 2,500
Initial pressure loss at nominal load Pa 130
Recommended final pressure loss Pa 450
Maximum thermal resistance ˚C 100
Pre
ssur
e lo
ss [P
a]
150
120
90
60
30
0 1 500 2 500Volume flow rate [m3/h/m2]
FILT
ER
ME
DIA
PO
CK
ET
FILT
ERS
FRA
ME
FILT
ERS
CO
MPA
CT
FILT
ERS
AB
SOLU
TE F
ILTE
RS
FOR
MIC
RO
PAR
TIC
LES
CO
MP
ON
ENTS
FO
R
CLE
AN
RO
OM
SFI
LTER
UN
ITS
FOR
AIR
H
AN
DLI
NG
PIP
ELIN
ES
MO
UN
TIN
G F
RA
ME
SA
DSO
RP
TIO
N F
ILTE
RS
WIT
H A
CTI
VATE
D C
AR
BO
NA
CC
ES
SOR
IES
18
As
part
of o
ur p
rogr
amm
e of
con
tinuo
us im
prov
emen
t, K
S K
lima-
Serv
ice,
a.s
. re
serv
es th
e rig
ht to
cha
nge
the
spec
ifica
tion
with
out p
rior n
otic
e. 0
2/2
014
KS Glas 1" and KS Glas 2"Filter media – glass fibres
Filtration class according to EN 779:2012
G2, G3Delivery options
rolls, cut sizesPossibility of regeneration
no
Pressure loss diagram Glas 1" Glas 2"
Pre
ssur
e lo
ss [P
a]
100
80
60
40
20
0 1 000 2 000 3 000 4 000
Volume flow rate [m3/h/m2]
Filter propertiesThe filter medium KS Glas 1“, 2“ consist of elastic, twisted, randomly arranged glass fibres fixed with a special plastic in the point of contact. The medium is saturated with a non-harmful dust binding agent in order to achieve better binding and separation of particles.
Field of applicationThe media are used as pre-filters in air-conditioning and ventilation units, especially to capture coarse dust particles in industry, warehouses and production halls.
MaterialGlass fibre
Waste disposalLandfilling or incineration in authorised incineration plants.
Technical data Unit of measure Glas 1” Glas 2”
Filtration class according to EN 779:2012 – G2 G3
Mean separation (Am) according to EN 779:2012 % 65 – 80 80 – 90
Nominal air flow rate m3/h/m2 3,400 3,400
Initial pressure loss at nominal load Pa 15 20
Recommended final pressure loss Pa 200 250
Maximum thermal resistance ˚C 80 80
19KS Glas C and KS Glas 300Filter media – glass fibres; high thermal resistance
Filtration class according to EN 779:2012
M6, G4Delivery options
rolls, cut sizesPossibility of regeneration
no
Pressure loss diagram Glas C Glas 300
Pre
ssur
e lo
ss [P
a]
150
120
90
60
30
0 1 000 2 000 3 000 4 000
Volume flow rate [m3/h/m2]
Filter propertiesThe filter medium Glas C is made from glass fibres and features high thermal resistance up to 190 °C. The clean air side has a special protective layer. The special medium Glas 300 is made from glass fibres with thermal resistance up to 300 °C.
Field of applicationThe Glas C is used for separation of fine dust particles in drying plants and burning furnaces. Glas 300 is used for manufacture of filters for dying plants and burning furnaces in the automotive industry.
MaterialGlass fibre
Waste disposalLandfilling or incineration in authorised incineration plants.
Technical data Unit of measure Glas C Glas 300
Filtration class according to EN 779:2012 – M6 G4
Mean separation (Am) according to EN 779:2012 % – > 90
Mean efficiency (Em) for 0.4 μm particles
according to EN 779:2012% 60 – 80 –
Nominal air flow rate m3/h/m2 2,500 3,400
Initial pressure loss at nominal load Pa 170 80
Recommended final pressure loss Pa 500 250
Maximum thermal resistance ˚C 200 300
FILT
ER
ME
DIA
PO
CK
ET
FILT
ERS
FRA
ME
FILT
ERS
CO
MPA
CT
FILT
ERS
AB
SOLU
TE F
ILTE
RS
FOR
MIC
RO
PAR
TIC
LES
CO
MP
ON
ENTS
FO
R
CLE
AN
RO
OM
SFI
LTER
UN
ITS
FOR
AIR
H
AN
DLI
NG
PIP
ELIN
ES
MO
UN
TIN
G F
RA
ME
SA
DSO
RP
TIO
N F
ILTE
RS
WIT
H A
CTI
VATE
D C
AR
BO
NA
CC
ES
SOR
IES
20
As
part
of o
ur p
rogr
amm
e of
con
tinuo
us im
prov
emen
t, K
S K
lima-
Serv
ice,
a.s
. re
serv
es th
e rig
ht to
cha
nge
the
spec
ifica
tion
with
out p
rior n
otic
e. 0
2/2
014
KS PA Grün 2", KS PA Grün 3", KS PA Grün 4"Filter media – Paint Stop, floor filters
Filtration class according to EN 779:2012
G2, G3Delivery options
rolls, cut sizesPossibility of regeneration
no
Pressure loss diagram PA 2" PA 3" PA 4"
Pre
ssur
e lo
ss [P
a]
50
40
30
20
10
0 1 000 2 000 3 000 4 000
Volume flow rate [m3/h/m2]
Filter propertiesSeparator of paint aerosols (Paint stop) made from progressively thickened and highly elastic, nonflammable glass fibres. The material features a high paint aerosols accumulation capacity from 3,500 to 5,900 g/m2 and thus a long servicing interval of replacement.
Field of applicationThey are used in particular for adsorption of paint aerosols as so-called floor filters in spraying boxes. The striking green colour of the medium is the “dirty air side”, i.e. the inlet side. This is how the filter should be mounted correctly.
MaterialGlass fibre
Waste disposalLandfilling or incineration in authorised incineration plants.
Technical data Unit of measure PA Grün 2” PA Grün 3” PA Grün 4”
Filtration class according to EN 779:2012 – G2 G3 G4
Mean separation (Am) according to EN 779:2012 % 94 96 98
Nominal air flow rate m3/h/m2 2,900 2,900 2,900
Initial pressure loss at nominal load Pa 10 12 16
Recommended final pressure loss Pa 80 80 130
Maximum thermal resistance ˚C 150 150 150
Aerosol accumulation capacity g/m2 3,100 3,500 3,900
21VS LAK filter mediaFilter media – filter for painting shops for separation of over spraying and colour mist from water-borne and polyurethane paints
Filtration class according to EN 779:2012
G3Delivery options
rolls 0,75 × 20 m, rolls 1 × 20 m rolls 2 × 20 m; cut sizes according to the customer’s requirements, possibility to mount the medium into a plastic or zinc-coated framePossibility of regeneration
no
Pressure loss diagram VS LAK
Pre
ssur
e lo
ss [P
a]
100
80
60
40
20
0 1 000 2 000 3 000 4 000
Volume flow rate [m3/h/m2]
Filter propertiesThe filter is made with a filter media from glass fibres randomly arranged with high elasticity and low compressibility. This unique, elastic structure of the medium provides high absorbing capacity of the filter and encourages the operating safety of mounted filters. The medium contains also a special binder that binds excess paint containing a high portion of water component. The striking purple colour of the medium is the “dirty air side”, i.e. the inlet side. This is how the filter should be mounted correctly.
Field of applicationThe VS LAK filter is most often used in the first filtration stage and it captures aerosols of excess paint (so-called paint fog), including dry paint or varnish particles.
MaterialGlass fibre
Waste disposalLandfilling
Technical data Unit of measure VS LAK
Filtration class according to EN 779:2012 – G3
Separation according to EN 779:2012 % 98
Nominal air flow rate m3/h/m2 2 900
Initial pressure loss at nominal load Pa 28
Thermal resistance of medium ˚C do 120 C
Thickness of medium 3" (cca 7–8 cm)
Replaceable plastic (zinc-coated) frames – in required dimensions, a cut-to-size medium is always part of delivery
Absorbing capacity g/m2 up to 6,000
The filter medium is silicon free
FILT
ER
ME
DIA
PO
CK
ET
FILT
ERS
FRA
ME
FILT
ERS
CO
MPA
CT
FILT
ERS
AB
SOLU
TE F
ILTE
RS
FOR
MIC
RO
PAR
TIC
LES
CO
MP
ON
ENTS
FO
R
CLE
AN
RO
OM
SFI
LTER
UN
ITS
FOR
AIR
H
AN
DLI
NG
PIP
ELIN
ES
MO
UN
TIN
G F
RA
ME
SA
DSO
RP
TIO
N F
ILTE
RS
WIT
H A
CTI
VATE
D C
AR
BO
NA
CC
ES
SOR
IES
22
As
part
of o
ur p
rogr
amm
e of
con
tinuo
us im
prov
emen
t, K
S K
lima-
Serv
ice,
a.s
. re
serv
es th
e rig
ht to
cha
nge
the
spec
ifica
tion
with
out p
rior n
otic
e. 0
2/2
014
KS AFVH – floor pre-filterFilter media – floor filters
Delivery options
sheets of various dimensions (four types) 0,68 m × 10 m 0,75 m × 10 m 0,90 m × 10 m 1 m × 10 mPossibility of regeneration
no
Filter propertiesProtective filter for capturing of paint drops during spraying. The Venturi effect combined with changes in flow of air containing paint particles provide a highly efficient protection. All types consist of two fanfold cardboards. Openings in the front panel are placed asymmetrically against openings in the back panel. When air is passing through the filter, the flow changes in all the three axes. Separated liquid particles are isolated in pockets formed in the back panel with deeper V folds.
Field of applicationThey are used independently or as pre-filters in multistage filtration systems of exhaust equipment in paint shops.
MaterialFolded cardboard from recycled paper
Waste disposalLandfilling or incineration in authorised incineration plants.
Technical data Unit of measure KS AFVH – standard
Absorbing capacity kg/m2 18
Efficiency at the speed of 1 m/s % 98
Initial pressure loss at speed of 1 m/s
for dimensions 592 × 592Pa 90
Recommended final pressure loss Pa 130
Air contaminated with paint drops
Clean air
23POCKET FILTERS
Pocket filters are still the most used type of filters in all air-handling units. The name “pocket filter” is derived from its basic structural element, the pocket. The conic shape of pockets gives the best properties to the filter, it allows to use 100 % of filter area and to decrease the total initial pressure loss of the pocket filter. The new design of pocket filters with conic pockets guaranties energy costs savings thanks to lower pressure losses and longer service life of the filter.
We offer the possibility to deliver semi-finished products in form of sewn pockets or entire filter sleeves for subsequent processing and production of pocket filters. The filter pockets as well as sleeves are made from a synthetic or glass fibre medium.
Pocket filters are made in many variants, from filtration class G3 to F9 according to CSN EN 779:2012. The basic structural element of the filter is the filter medium. The most commonly used medium is a synthetic medium. Another possibility is a glass fibre medium or a specially adapted medium for potentially explosive atmospheres. Pocket filters with an absorption medium may be used in environments where it is necessary to remove odours. Development of filter media for atmospheric dust brings new solutions, e.g. nanofibres media, media with low pressure losses, media with high absorbing capacity, media with antibacterial treatment or media with aramid fibres with thermal resistance up to 240 °C.
The pocket filter frame is also made in various designs. The most common ones are made of plastic or zinc-coated. Another possibility is a stainless steel version of the frame. Pocket filter separators are made entirely from plastic, wood or zinc-coated. The range of sizes and design variants of pocket filters is almost unlimited which makes them suitable for use in air-handling equipment, both in older units and in new, modern air filtration equipment. They are suitable for e.g. food-processing, chemical, pharmaceutical industry, electric power plants, painting boxes, hospitals, offices, hotels and other premises.
The production process and input components for all pocket filters take into consid-eration energy performance.
Automatic stitching of conical pockets for use of the entire filtration area of the pocket filter
Pocket filter - conical pocket
24
As
part
of o
ur p
rogr
amm
e of
con
tinuo
us im
prov
emen
t, K
S K
lima-
Serv
ice,
a.s
. re
serv
es th
e rig
ht to
cha
nge
the
spec
ifica
tion
with
out p
rior n
otic
e. 0
2/2
014
KS PAK 85 E, F7Pocket filters – low energy demand, high absorbing capacity
Filtration class according to EN 779:2012
F7Delivery options
standard EURO line, non-standard dimensions according to customer’s requirementsPossibility of regeneration
no Energy class KS PAK 85 E, F7
A <– 1 200
Filter propertiesThe pocket filter KS PAK 85 E, F7 is made from polyester with a special inner structure. The mechanically bound fibres prevent spreading of and provide resistance to humidity and potentially harmful bacteria and chemicals. The medium structure has virtually two times larger filtration area in comparison with common pocket filters of the same dimensions. The pressure loss is up to 30 % lower. The inner area provides much higher dust particles absorbing capacity and the filter service life is 30 to 60 % longer. These qualities of the pocket filter do not compromise its performance; the performance level is better in each filtration stage. The pocket filter KS PAK 85 E, F7 complies with the EN 779:2012 standard requirements with regard to both the mean efficiency level (Em), and minimum efficiency (M.E.) in electrically discharged state.
Field of applicationThe filter is used as pre-filter or main filter for absorption of fine dust in air-conditioning systems in food-processing industry, pharmaceutical operations, hospitals and other areas.
Technical data Unit of measureKS PAK 85-E
592 × 592 × 635 mm
Filtration class according to EN 779:2012 – F7
Mean efficiency (Em) for 0.4 μm particles % 99
Minimum efficiency (M.E. for 0.4 μm particles) % 35.6
Nominal air flow rate for a filter of dimensions 592 × 592 × 635 mm m3/h 3,400
Initial pressure loss at nominal load Pa 97
Recommended final pressure loss Pa 450
Dust absorbing capacity g 526.2
Pre
ssur
e lo
ss [P
a]
100
80
60
40
20
0 1 000 2 000 3 000 4 000
Volume flow rate [m3/h/m2] for dimensions 592 × 592 × 635 mm
Pressure loss diagram KS PAK 85 E
25KS PAK 25 and KS PAK 35Pocket filters
Pressure loss diagram KS PAK 25, KS PAK 35
Pre
ssur
e lo
ss [P
a]
100
80
60
40
20
0 1 000 2 000 3 000 4 000
Volume flow rate [m3/h]
for dimensions 592 × 592 × 360 mm
Filtration class according to EN 779:2012
G3, G4Delivery options
standard EURO line, non-standard dimensions according to customer’s requirementsPossibility of regeneration
no
Filter propertiesThe filters are made from synthetic media with progressive structure. The filter pockets of conical shape with stitching and sealing are mounted in a frame. The frame is made of plastic and separators are wooden or plastic. On demand, it is possible to supply a zinccoated frame and metallic separators. Large filtration area and high absorbing capacity.
Field of applicationThey are used as pre-filters or main filters to separate coarse dust in ventilation and airconditioning units.
MaterialSynthetic fibre
Waste disposalLandfilling or incineration in authorised incineration plants.
Technical data Unit of measureKS PAK 25
592 × 592 × 360 mm
KS PAK 35
592 × 592 × 360 mm
Filtration class according to EN 779:2012 – G3 G4
Mean separation (Am) according to EN 779:2012 % 80 – 90 > 90
Nominal air intake flow rate to filter area m/s 0.4 0.4
Nominal air flow rate for a filter of dimensions 592 × 592 × 360 mm m3/h 3,400 3,400
Initial pressure loss at nominal load Pa 35 35
Recommended final pressure loss Pa 250 250
Maximum thermal resistance – metal frame (plastic frame) ˚C 100 (75) 100 (75)
FILT
ER M
EDIA
PO
CK
ET
FILT
ER
S
FRA
ME
FILT
ERS
CO
MPA
CT
FILT
ERS
AB
SOLU
TE F
ILTE
RS
FOR
MIC
RO
PAR
TIC
LES
CO
MP
ON
ENTS
FO
R
CLE
AN
RO
OM
SFI
LTER
UN
ITS
FOR
AIR
H
AN
DLI
NG
PIP
ELIN
ES
MO
UN
TIN
G F
RA
ME
SA
DSO
RP
TIO
N F
ILTE
RS
WIT
H A
CTI
VATE
D C
AR
BO
NA
CC
ES
SOR
IES
26
As
part
of o
ur p
rogr
amm
e of
con
tinuo
us im
prov
emen
t, K
S K
lima-
Serv
ice,
a.s
. re
serv
es th
e rig
ht to
cha
nge
the
spec
ifica
tion
with
out p
rior n
otic
e. 0
2/2
014
KS PAK 45 and KS PAK 55Pocket filters
Pressure loss diagram KS PAK 45 KS PAK 55
Filtration class according to EN 779:2012
M5Delivery options
standard EURO line, non-standard dimensions according to customer’s requirementsPossibility of regeneration
no
Filter propertiesThe modern filter medium from synthetic fibres arranged in conical pockets enables to manufacture pocket filters with long service-life at optimum pressure losses and low energy costs. As standard, the filters are supplied in a completely incinerable design with a plastic frame and plastic or wooden separators or, if requested, with a zinc-coated frame and metal separators.
Field of applicationThey are used as the second or the only stage of filtration for separation of fine dust in the health sector, restaurants, hotels, etc.
MaterialSynthetic fibre
Waste disposalLandfilling or incineration in authorised incineration plants.
Technical data Unit of measureKS PAK 45
592 × 592 × 625 mm
KS PAK 55
592 × 592 × 500 mm
Filtration class according to EN 779:2012 – M5 M5
Mean efficiency (Em) for 0.4 μm particles % 40 – 60 40 – 60
Nominal air intake flow rate to filter area m/s 0.4 0.4
Nominal air flow rate for a filter of dimensions
592 × 592 × 625 (500) mmm3/h 3,400 3,400
Initial pressure loss at nominal load Pa 55 35
Recommended final pressure loss Pa 450 450
Maximum thermal resistance – metal frame (plastic frame) ˚C 100 (75) 100 (75)
Pre
ssur
e lo
ss [P
a]
100
80
60
40
20
0 1 000 2 000 3 000 4 000
Volume flow rate [m3/h]
for dimensions 592 × 592 × 625 (500) mm
27KS PAK 62Pocket filter
Pressure loss diagram KS PAK 62
Filtration class according to EN 779:2012
M6Delivery options
standard EURO line, non-standard dimensions according to customer’s requirementsPossibility of regeneration
no
Filter propertiesThe modern filter medium from synthetic fibres arranged in conical filter pockets with stitching and sealing enables to manufacture pocket filters with long service-life at optimum pressure losses and with low energy costs. As standard, the filters are supplied in a completely incinerable design with a plastic frame and plastic or wooden separators or, if requested, with a zinc-coated frame and metal separators.
Field of applicationThey are used as the second or the only stage of filtration for separation of fine dust in the health sector, restaurants, hotels, etc.
MaterialSynthetic fibre
Waste disposalLandfilling or incineration in authorised incineration plants
Technical data Unit of measureKS PAK 62
592 × 592 × 625 mm
Filtration class according to EN 779:2012 – M6
Mean efficiency (Em) for 0.4 μm particles % 60 – 80
Nominal air intake flow rate to filter area m/s –
Nominal air flow rate for a filter of dimensions 592 × 592 × 625 mm m3/h 3,400
Initial pressure loss at nominal load Pa 65
Recommended final pressure loss Pa 450
Maximum thermal resistance – metal frame (plastic frame) ˚C 100 (75)
Pre
ssur
e lo
ss [P
a]
100
80
60
40
20
0 1 000 2 000 3 000 4 000
Volume flow rate [m3/h]
for dimensions 592 × 592 × 625 mm
FILT
ER M
EDIA
PO
CK
ET
FILT
ER
S
FRA
ME
FILT
ERS
CO
MPA
CT
FILT
ERS
AB
SOLU
TE F
ILTE
RS
FOR
MIC
RO
PAR
TIC
LES
CO
MP
ON
ENTS
FO
R
CLE
AN
RO
OM
SFI
LTER
UN
ITS
FOR
AIR
H
AN
DLI
NG
PIP
ELIN
ES
MO
UN
TIN
G F
RA
ME
SA
DSO
RP
TIO
N F
ILTE
RS
WIT
H A
CTI
VATE
D C
AR
BO
NA
CC
ES
SOR
IES
28
As
part
of o
ur p
rogr
amm
e of
con
tinuo
us im
prov
emen
t, K
S K
lima-
Serv
ice,
a.s
. re
serv
es th
e rig
ht to
cha
nge
the
spec
ifica
tion
with
out p
rior n
otic
e. 0
2/2
014
KS PAK 85Pocket filter
Pressure loss diagram KS PAK 85
Filtration class according to EN 779:2012
F7Delivery options
standard EURO line, non-standard dimensions according to customer’s requirementsPossibility of regeneration
no
Filter propertiesThe modern filter medium from synthetic fibres arranged in automatically sewn conical pockets enables to manufacture pocket filters with long service-life at optimum pressure losses and low energy costs. As standard, the filters are supplied in a completely incinerable design with a plastic frame and plastic or wooden separators or, if requested, with a zinc-coated frame and metal separators. F7 is the most demanded filtration class for pocket filters for separation of fine dust.
Field of applicationThey are used as the second or the last stage of filtration for separation of fine dust in telecommunications central offices, food-processing industry, hospitals, etc.
MaterialSynthetic fibre
Waste disposalLandfilling or incineration in authorised incineration plants.
Technical data Unit of measureKS PAK 85
592 × 592 × 635 mm
Filtration class according to EN 779:2012 – F7
Mean efficiency (Em) for 0.4 μm particles % 80 – 90
Minimum efficiency (M.E. for 0.4 μm particles) % 35
Nominal air intake flow rate to filter area m/s 0.15
Nominal air flow rate for a filter of dimensions 592 × 592 × 635 mm m3/h 3,400
Initial pressure loss at nominal load Pa 75
Recommended final pressure loss Pa 450
Maximum thermal resistance – metal frame (plastic frame) ˚C 100 (75)
Pre
ssur
e lo
ss [P
a]
100
80
60
40
20
0 1 000 2 000 3 000 4 000
Volume flow rate [m3/h]
for dimensions 592 × 592 × 635 mm
29KS PAK 95Pocket filter
Pressure loss diagram KS PAK 95
Filtration class according to CSN EN 779:2012
F8Delivery options
standard EURO line, non-standard dimensions according to customer’s requirementsPossibility of regeneration
no
Filter propertiesThe modern filter medium from synthetic fibres arranged in conical filter pockets with stitching and sealing enables to manufacture pocket filters with long service-life at optimum pressure losses and with low energy costs. As standard, the filters are supplied in a completely incinerable design with a plastic frame and plastic or wooden separators or, if requested, with a zinc-coated frame and metal separators.
Field of applicationThey are used as the second or the last stage of filtration for separation of fine dust in telecommunications central offices, food-processing industry, hospitals, etc.
MaterialSynthetic fibre
Waste disposalLandfilling or incineration in authorised incineration plants.
Technical data Unit of measureKS PAK 95
592 × 592 × 635 mm
Filtration class according to EN 779:2012 – F8
Mean efficiency (Em) for 0.4 μm particles % 90 – 95
Minimum efficiency (M.E. for 0.4 μm particles) % 55
Nominal air intake flow rate to filter area m/s 0.19
Nominal air flow rate for a filter of dimensions 592 × 592 × 635 mm m3/h 3,400
Initial pressure loss at nominal load Pa 110
Recommended final pressure loss Pa 450
Maximum thermal resistance – metal frame (plastic frame) ˚C 100 (75)
Pre
ssur
e lo
ss [P
a]
150
120
90
60
30
0 1 000 2 000 3 000 4 000
Volume flow rate [m3/h]
for dimensions 592 × 592 × 635 mm
FILT
ER M
EDIA
PO
CK
ET
FILT
ER
S
FRA
ME
FILT
ERS
CO
MPA
CT
FILT
ERS
AB
SOLU
TE F
ILTE
RS
FOR
MIC
RO
PAR
TIC
LES
CO
MP
ON
ENTS
FO
R
CLE
AN
RO
OM
SFI
LTER
UN
ITS
FOR
AIR
H
AN
DLI
NG
PIP
ELIN
ES
MO
UN
TIN
G F
RA
ME
SA
DSO
RP
TIO
N F
ILTE
RS
WIT
H A
CTI
VATE
D C
AR
BO
NA
CC
ES
SOR
IES
30
As
part
of o
ur p
rogr
amm
e of
con
tinuo
us im
prov
emen
t, K
S K
lima-
Serv
ice,
a.s
. re
serv
es th
e rig
ht to
cha
nge
the
spec
ifica
tion
with
out p
rior n
otic
e. 0
2/2
014
KS PAK 98Pocket filter
Pressure loss diagram KS PAK 98
Filtration class according to CSN EN 779:2012
F9Delivery options
standard EURO line, non-standard dimensions according to customer’s requirementsPossibility of regeneration
no
Filter propertiesThe modern filter medium from synthetic fibres arranged in conical filter pockets with stitching and sealing enables to manufacture pocket filters with long service-life at optimum pressure losses and with low energy costs. As standard, the filters are supplied in a completely incinerable design with a plastic frame and plastic or wooden separators or, if requested, with a zinc-coated frame and metal separators.
Field of applicationThey are used as the second or the last stage of filtration for separation of fine dust in telecommunications central offices, food-processing industry, hospitals, etc.
MaterialSynthetic fibre
Waste disposalLandfilling or incineration in authorised incineration plants.
Technical data Unit of measureKS PAK 98
592 × 592 × 635 mm
Filtration class according to EN 779:2012 – F9
Mean efficiency (Em) for 0.4 μm particles
according to EN 779:2012% 95 < Em
Minimum efficiency (M.E. for 0.4 μm particles) % 70
Nominal air intake flow rate to filter area m/s 0.19
Nominal air flow rate for a filter of dimensions 592 × 592 × 635 mm m3/h 3,400
Initial pressure loss at nominal load Pa 140
Recommended final pressure loss Pa 450
Maximum thermal resistance – metal frame (plastic frame) ˚C 100 (75)
Pre
ssur
e lo
ss [P
a]
150
120
90
60
30
0 1 000 2 000 3 000 4 000
Volume flow rate [m3/h]
for dimensions 592 × 592 × 635 mm
31KS PAK 45 and KS PAK 62Pocket filters – glass fibre
Pressure loss diagram KS PAK 62 KS PAK 45
Filtration class according to EN 779:2012
M5, M6Delivery options
standard EURO line, non-standard dimensions according to customer’s requirementsPossibility of regeneration
no
Filter propertiesPocket filters PAK 45 and 62 are made from glass fibres. The filter pockets of conical shape with stitching and sealing are mounted in a frame. As standard, the filters are supplied in a completely incinerable design with a plastic frame and plastic or wooden separators or, if requested, with a zinc-coated frame and metal separators.
Field of applicationThey are used as the second or the only stage of filtration for separation of fine dust in the health sector, restaurants, hotels, etc.
MaterialGlass fibre
Waste disposalLandfilling or incineration in authorised incineration plants.
Technical data Unit of measureKS PAK 45
592 × 592 × 625 mm
KS PAK 62
592 × 592 × 625 mm
Filtration class according to EN 779:2012 – M5 M6
Mean efficiency (Em) according to EN 779:2012 % 40 – 60 60 – 80
Nominal air intake flow rate to filter area m/s 0.4 0.16
Nominal air flow rate for a filter of dimensions 592 × 592 × 625 mm m3/h 3,400 3,400
Initial pressure loss at nominal load Pa 55 72
Recommended final pressure loss Pa 450 450
Maximum thermal resistance – metal frame (plastic frame) ˚C 100 (75) 100 (75)
Pre
ssur
e lo
ss [P
a]
100
80
60
40
20
0 1 000 2 000 3 000 4 000
Volume flow rate [m3/h]
for dimensions 592 × 592 × 625 mm
FILT
ER M
EDIA
PO
CK
ET
FILT
ER
S
FRA
ME
FILT
ERS
CO
MPA
CT
FILT
ERS
AB
SOLU
TE F
ILTE
RS
FOR
MIC
RO
PAR
TIC
LES
CO
MP
ON
ENTS
FO
R
CLE
AN
RO
OM
SFI
LTER
UN
ITS
FOR
AIR
H
AN
DLI
NG
PIP
ELIN
ES
MO
UN
TIN
G F
RA
ME
SA
DSO
RP
TIO
N F
ILTE
RS
WIT
H A
CTI
VATE
D C
AR
BO
NA
CC
ES
SOR
IES
32
As
part
of o
ur p
rogr
amm
e of
con
tinuo
us im
prov
emen
t, K
S K
lima-
Serv
ice,
a.s
. re
serv
es th
e rig
ht to
cha
nge
the
spec
ifica
tion
with
out p
rior n
otic
e. 0
2/2
014
KS PAK 85Pocket filters – glass fibre
Pressure loss diagram KS PAK 85
Filtration class according to EN 779:2012
F7Delivery options
standard EURO line, non-standard dimensions according to customer’s requirementsPossibility of regeneration
no
Filter propertiesPocket filters KS PAK 85 are made from glass fibres, the filter medium is reinforced with synthetic laminated cheese cloth on the clean air intake side. The filter pockets of conical shape with stitching and sealing are mounted in a frame. As standard, the filters are supplied in a completely incinerable design with a plastic frame and plastic or wooden separators or, if requested, with a zinc-coated frame and metal separators.
Field of applicationThey are used as the second or the last stage of filtration for separation of fine dust in telecommunications central offices, food-processing industry, hospitals, etc.
MaterialGlass fibre
Waste disposalLandfilling or incineration in authorised incineration plants.
Technical data Unit of measureKS PAK 85
592 × 592 × 635 mm
Filtration class according to EN 779:2012 – F7
Mean efficiency (Em) for 0.4 μm particles % 80 – 90
Minimum efficiency (M.E. for 0.4 μm particles) % 35
Nominal air intake flow rate to filter area m/s 0.15
Nominal air flow rate for a filter of dimensions 592 × 592 × 635 mm m3/h 3,400
Initial pressure loss at nominal load Pa 110
Recommended final pressure loss Pa 450
Maximum thermal resistance – metal frame (plastic frame) ˚C 100 (75)
Pre
ssur
e lo
ss [P
a]
150
120
90
60
30
0 1 000 2 000 3 000 4 000
Volume flow rate [m3/h]
for dimensions 592 × 592 × 635 mm
33KS PAK 95 and KS PAK 98Pocket filters – glass fibre
Pressure loss diagram KS PAK 95 KS PAK 98
Filtration class according to EN 779:2012
F8, F9Delivery options
standard EURO line, non-standard dimensions according to customer’s requirementsPossibility of regeneration
no
Filter propertiesPocket filters KS PAK 95 and KS PAK 98 are made from glass fibres, the filter medium is reinforced with synthetic laminated cheese cloth on the clean air intake side. The filter pockets of conical shape with stitching and sealing are mounted in a frame. As standard, the filters are supplied in a completely incinerable design with a plastic frame and plastic or wooden separators or, if requested, with a zinc-coated frame and metal separators.
Field of applicationThey are used as the second or the last stage of filtration for separation of fine dust in telecommunications central offices, food-processing industry, hospitals, etc.
MaterialGlass fibre
Waste disposalLandfilling or incineration in authorised incineration plants.
Technical data Unit of measureKS PAK 95
592 × 592 × 635 mm
KS PAK 98
592 × 592 × 635 mm
Filtration class according to EN 779:2012 – F8 F9
Mean efficiency (Em) for 0.4 μm particles % 90 – 95 95<
Minimum efficiency (M.E. for 0.4 μm particles) % 55 70
Nominal air intake flow rate to filter area m/s 0.15 0.15
Nominal air flow rate for a filter of dimensions 592 × 592 × 635 mm m3/h 3,400 3,400
Initial pressure loss at nominal load Pa 135 180
Recommended final pressure loss Pa 450 450
Maximum thermal resistance – metal frame (plastic frame) ˚C 100 (75) 100 (75)
180
Pre
ssur
e lo
ss [P
a]
150
120
90
60
30
0 1 000 2 000 3 000 4 000
Volume flow rate [m3/h]
for dimensions 592 × 592 × 635 mm
FILT
ER M
EDIA
PO
CK
ET
FILT
ER
S
FRA
ME
FILT
ERS
CO
MPA
CT
FILT
ERS
AB
SOLU
TE F
ILTE
RS
FOR
MIC
RO
PAR
TIC
LES
CO
MP
ON
ENTS
FO
R
CLE
AN
RO
OM
SFI
LTER
UN
ITS
FOR
AIR
H
AN
DLI
NG
PIP
ELIN
ES
MO
UN
TIN
G F
RA
ME
SA
DSO
RP
TIO
N F
ILTE
RS
WIT
H A
CTI
VATE
D C
AR
BO
NA
CC
ES
SOR
IES
34
As
part
of o
ur p
rogr
amm
e of
con
tinuo
us im
prov
emen
t, K
S K
lima-
Serv
ice,
a.s
. re
serv
es th
e rig
ht to
cha
nge
the
spec
ifica
tion
with
out p
rior n
otic
e. 0
2/2
014
KS PAK AST/2 and KS PAK ASTPocket filters – antistatic design
Pressure loss diagram KS PAK AST/2 KS PAK AST
Filtration class according to EN 779:2012
M5, F7Delivery options
standard EURO line, non-standard dimensions according to customer’s requirementsPossibility of regeneration
no
Filter propertiesPocket filters KS PAK AST and AST/2 are made from a special antistatic, electrostatically conductive filter medium that meets the most demanding parameters for use in potentially explosive environments. The V-shaped sewn pockets are mounted in a U-section front frame from using a new technology to guarantee electrostatic properties of the filter. The frames are zinc-coated and they have a grounding terminal (M5 nut bolt). Certified by Physical-Technical Testing Institute - Radvanice.
Field of applicationThey are used in explosive environments, such as: paint shops, chemical plants and other specialised facilities.
MaterialSpecial filter media
Waste disposalLandfilling or incineration in authorised incineration plants.
Technical data Unit of measureKS PAK AST/2
592 × 592 × 500 mm
KS PAK AST
592 × 592 × 500 mm
Filtration class according to EN 779:2012 – M5 F7
Mean efficiency (Em) for 0.4 μm particles
according to EN 779:2012% 40 – 60 80 – 90
Nominal air flow rate for a filter of dimensions
592 × 592 × 500 mmm3/h 3,400 2,750
Initial pressure loss at nominal load Pa 110 90
Recommended final pressure loss Pa 300 300
Maximum thermal resistance ˚C 150 150
Pre
ssur
e lo
ss [P
a]
150
120
90
60
30
0 1 000 2 000 3 000 4 000
Volume flow rate [m3/h]
for dimensions 592 × 592 × 500 mm
35KS PAK SAM-G4 and KS PAK SAM-M5Pocket filters
Pressure loss diagram KS PAK SAM-G4 KS PAK SAM-M5
Filtration class according to EN 779:2012
G4, M5Delivery options
dimensions according to customer’s requirementsPossibility of regeneration
no
Filter propertiesSelf-supporting pocket filters without frames. For use in older air-handling units - type BKC and KOVONA.
Field of applicationThey are used as pre-filters or main filters for separating coarse dust for filtration classes G4. They are used as the second or the only filtration stage for separation of fine dust for filtration classes M5.
MaterialSynthetic fibre
Waste disposalLandfilling or incineration in authorised incineration plants.
Technical data Unit of measureKS PAK SAM-G4
600 × 600 × 600 mm
KS PAK SAM-M5
600 × 600 × 600 mm
Filtration class according to EN 779:2012 – G4 M5
Mean separation / mean efficiency (Am) according to EN 779:2012 % 93/35 97/55
Nominal air flow rate for a filter of dimensions
600 × 600 × 600 mmm3/h 3,400 3,400
Initial pressure loss at nominal load Pa 40 60
Recommended final pressure loss Pa 250 250
Pre
ssur
e lo
ss [P
a]
100
80
60
40
20
0 1 000 2 000 3 000 4 000
Volume flow rate [m3/h]
for dimensions 600 × 600 × 600 mm
FILT
ER M
EDIA
PO
CK
ET
FILT
ER
S
FRA
ME
FILT
ERS
CO
MPA
CT
FILT
ERS
AB
SOLU
TE F
ILTE
RS
FOR
MIC
RO
PAR
TIC
LES
CO
MP
ON
ENTS
FO
R
CLE
AN
RO
OM
SFI
LTER
UN
ITS
FOR
AIR
H
AN
DLI
NG
PIP
ELIN
ES
MO
UN
TIN
G F
RA
ME
SA
DSO
RP
TIO
N F
ILTE
RS
WIT
H A
CTI
VATE
D C
AR
BO
NA
CC
ES
SOR
IES
36
As
part
of o
ur p
rogr
amm
e of
con
tinuo
us im
prov
emen
t, K
S K
lima-
Serv
ice,
a.s
. re
serv
es th
e rig
ht to
cha
nge
the
spec
ifica
tion
with
out p
rior n
otic
e. 0
2/2
014
KS PAK DR-G3Pocket filter in a wire frame
Pressure loss diagram KS PAK DR-G3
Filtration class according to EN 779:2012
G3Delivery options
dimensions according to customer’s requirementsPossibility of regeneration
no
Filter propertiesSpecial pocket filters in a wire frame Possibility to replace worn-out filter pockets and simple mounting of new ones into the frame.
Field of applicationThey are used as pre-filters or main filters for separation of coarse dust.
MaterialSynthetic fibre, steel wire of 5 mm diameter
Waste disposalLandfilling or incineration in authorised incineration plants.
Technical data Unit of measureKS PAK DR-G3
592 × 592 × 592 mm
Filtration class according to EN 779:2012 – G3
Mean separation (Am) according to EN 779:2012 % 80 – 90
Nominal air flow rate for a filter of dimensions 592 × 592 × 592 mm m3/h 3,400
Initial pressure loss at nominal load Pa 30
Recommended final pressure loss Pa 200
Maximum thermal resistance ˚C 100
Pre
ssur
e lo
ss [P
a]
100
80
60
40
20
0 1 000 2 000 3 000 4 000
Volume flow rate [m3/h]
for dimensions 592 × 592 × 592 mm
37KS PAK DR-G4Pocket filter in a wire frame
Pressure loss diagram KS PAK DR-G4
Filtration class according to EN 779:2012
G4Delivery options
dimensions according to customer’s requirementsPossibility of regeneration
no
Filter propertiesSpecial pocket filters in a wire frame Possibility to replace worn-out filter pockets and simple mounting of new ones into the frame.
Field of applicationThey are used as pre-filters or main filters for separation of coarse dust.
MaterialSynthetic fibre, steel wire of 5 mm diameter
Waste disposalLandfilling or incineration in authorised incineration plants.
Technical data Unit of measureKS PAK DR-G4
592 × 592 × 592 mm
Filtration class according to EN 779:2012 – G4
Mean separation (Am) according to EN 779:2012 % >90
Nominal air intake flow rate to filter area m/s –
Nominal air flow rate for a filter of dimensions 592 × 592 × 592 mm m3/h 3,400
Initial pressure loss at nominal load Pa 40
Recommended final pressure loss Pa 250
Maximum thermal resistance ˚C 100
Pre
ssur
e lo
ss [P
a]
100
80
60
40
20
0 1 000 2 000 3 000 4 000
Volume flow rate [m3/h]
for dimensions 592 × 592 × 592 mm
FILT
ER M
EDIA
PO
CK
ET
FILT
ER
S
FRA
ME
FILT
ERS
CO
MPA
CT
FILT
ERS
AB
SOLU
TE F
ILTE
RS
FOR
MIC
RO
PAR
TIC
LES
CO
MP
ON
ENTS
FO
R
CLE
AN
RO
OM
SFI
LTER
UN
ITS
FOR
AIR
H
AN
DLI
NG
PIP
ELIN
ES
MO
UN
TIN
G F
RA
ME
SA
DSO
RP
TIO
N F
ILTE
RS
WIT
H A
CTI
VATE
D C
AR
BO
NA
CC
ES
SOR
IES
38
As
part
of o
ur p
rogr
amm
e of
con
tinuo
us im
prov
emen
t, K
S K
lima-
Serv
ice,
a.s
. re
serv
es th
e rig
ht to
cha
nge
the
spec
ifica
tion
with
out p
rior n
otic
e. 0
2/2
014
KS PAK 35 LPocket filter for high loads
Pressure loss diagram KS PAK 35L pressure loss when clean pressure loss depending on dosing of dust
Filtration class according to EN 779:2012
G4Delivery options
standard EURO line, non-standard dimensions according to customer’s requirementsPossibility of regeneration
no
Filter propertiesThe pocket filter KS PAK 35L is specially designed to absorb coarse dust in order to achieve an extremely high absorbing capacity. The filter is made from a new synthetic filter media that uses progressive thickening of fibres and allows receiving and efficient accumulating of dust particles for the whole period of service life of the filter. The optimised and robust structure of the filter guarantees very low pressure losses for the whole period of use of the filter.
Field of applicationThe pocket filters KS PAK 35L are ideal for use as a prefilter or a main filter in air-handling units in areas with high dust nuisance. It may also be used as a pre-filter in paint shops and spraying boxes in the air intake and outlet sides.
MaterialSynthetic fibre
Waste disposalLandfilling or incineration in authorised incineration plants.
Technical data Unit of measureKS PAK 35L
592 × 592 × 360 mm
Filtration class according to EN 779:2012 – G4
Mean separation (Am) according to EN 779:2012 % 90 <_ Am
Nominal air intake flow rate to filter area m/s 0.4
Nominal air flow rate for a filter of dimensions 592 × 592 × 360 mm m3/h 3,400
Initial pressure loss at nominal load Pa 23
Recommended final pressure loss Pa 250
Absorbing capacity (dust accumulation capacity) g up to 620
Maximum thermal resistance – metal frame (plastic frame) ˚C 100 (75)
Pre
ssur
e lo
ss [P
a]
250
200
150
100
50
0
45
0
90
0
1 3
50
1 8
00
2 2
50
2 7
00
3 1
50
3 6
00
4 0
50
4 5
00
Volume flow rate [m3/h] for dimensions 592 × 592 × 360 mm
39FRAME FILTERS
Frame filters are very variable and, for their low depth, they are often a solution in limited spaces. They are supplied in filtration classes G2 – F9 according to CSN EN 779:2012.
The filter medium of frame filters may be made from both synthetic and glass fibre media, with a standard or very high thermal resistance. Another variant is an alu-minium intertwined medium or a polypropylene medium. Polypropylene is the light-est one of all textile fibres (0.91 g/m3), the fibre is resistant to chemicals, has a very good abrasion resistance, a minimum water absorbing capacity and a low tendency to get charged by static electricity.
The polypropylene filter medium is 100% hydrophobic and contains a mixture of polypropylene and other polymers specially mixed to achieve higher strength in com-parison with traditional materials (KS MPP filter).
The filter frame is made from a highly resistant hardened cardboard, zinc-coated metal, stainless steel or plastic. The most suitable variant of the separator is looked for in order to strengthen and increase stability of the frame filter. In order to strengthen the filter, the all-cardboard design uses cardboard grids covering the whole surface. This variant is the most common and the most demanded. In case of atypical frame filters or if required by the customer, a Z-line design of frame filters with wooden or cardboard separator may be supplied.
In some filters, the medium is normally sealed in the frame using a hot-melt system. Various designs of frame filters enable an unlimited dimensional line. Some types of frame filters are regenerable. They are used in particular in ventilation and air-condi-tioning of production halls, office and assembly rooms, telecommunication centres, health facilities, airport terminals.
40
As
part
of o
ur p
rogr
amm
e of
con
tinuo
us im
prov
emen
t, K
S K
lima-
Serv
ice,
a.s
. re
serv
es th
e rig
ht to
cha
nge
the
spec
ifica
tion
with
out p
rior n
otic
e. 0
2/2
014
KS Z1/2", KS Z1" and KS Z2"Frame filters
Pressure loss diagram Z1/2" Z1 Z2
Pre
ssur
e lo
ss [P
a]
100
80
60
40
20
0 1 000 2 000 3 000 4 000
Volume flow rate [m3/h] for dimensions 592 × 592 mm
Filtration class according to EN 779:2012
G2, G3Delivery options
dimensions according to customer’s requirementsPossibility of regeneration
no
Filter propertiesThe filter elements KS-Z are made from a glass fibre, progressively thickened filter media that is mounted in a stable cardboard or plastic frame. Both sides of the medium are covered with a perforated sheet metal, cardboard or plastic grid. The filter media is impregnated with a special dust binding agent. The filter elements KS-Z have an excellent dust particles accumulating properties with very low pressure losses.
Field of applicationThey are used in particular as pre-filters in airconditioning and air-handling units. They are employed in ventilation of industrial plants, social rooms, restaurants and hotels.
MaterialGlass fibre
Waste disposalLandfilling or incineration in authorised incineration plants.
Technical data Unit of measure Z ½” Z 1” Z 2”
Filtration class according to EN 779:2012 – G2 G2 G3
Mean separation (Am) according to EN 779:2012 % 65 – 80 65 – 80 80 – 90
Nominal air flow rate for a filter
of dimensions 592 × 592 mmm3/h 3,400 3,400 3,400
Initial pressure loss at nominal load Pa 35 40 60
Recommended final pressure loss Pa 140 180 180
Maximum thermal resistance ˚C 80 80 80
41KS PR-100Frame filter
Pressure loss diagram G3 G4 M5
Filtration class according to EN 779:2012
G3, G4, M5Delivery options
dimensions according to customer’s requirementsPossibility of regeneration
yes, replaceable filter medium
Filter propertiesThe filter medium from synthetic fibres is intertwined into a robust frame from a zinc-coated sheet metal. The medium is fixed by means of a block and steel separators. It is characterised by low economic costs, only for replacement of the filter medium. It is supplied in standard depths 48, 96 and 147 mm, as well as in other sizes.
Field of applicationVentilation of office and assembly rooms, central offices, airport terminals, etc.
MaterialSynthetic fibre
Waste disposalLandfilling or incineration in authorised incineration plants.
Technical data Unit of measure KS PR-100 KS PR-100 KS PR-100
Filtration class according to EN 779:2012 – G3 G4 M5
Mean separation (Am) according to EN 779:2012 % 80 – 90 > 90 –
Efficiency (Em) according to EN 779:2012 % – – 40 – 60
Nominal air flow rate for a filter of dimensions 592 × 592 mm m3/h 3,700 3,700 1,730
Initial pressure loss at nominal load Pa 35 50 45
Recommended final pressure loss Pa 250 250 250
Maximum thermal resistance ˚C 100 100 100
Pre
ssur
e lo
ss [P
a]
100
80
60
40
20
0 1 000 2 000 3 000 4 000
Volume flow rate [m3/h]
FILT
ER M
EDIA
PO
CK
ET
FILT
ERS
FRA
ME
FIL
TER
S
CO
MPA
CT
FILT
ERS
AB
SOLU
TE F
ILTE
RS
FOR
MIC
RO
PAR
TIC
LES
CO
MP
ON
ENTS
FO
R
CLE
AN
RO
OM
SFI
LTER
UN
ITS
FOR
AIR
H
AN
DLI
NG
PIP
ELIN
ES
MO
UN
TIN
G F
RA
ME
SA
DSO
RP
TIO
N F
ILTE
RS
WIT
H A
CTI
VATE
D C
AR
BO
NA
CC
ES
SOR
IES
42
As
part
of o
ur p
rogr
amm
e of
con
tinuo
us im
prov
emen
t, K
S K
lima-
Serv
ice,
a.s
. re
serv
es th
e rig
ht to
cha
nge
the
spec
ifica
tion
with
out p
rior n
otic
e. 0
2/2
014
Filter propertiesThe frame filters KS PR with a replaceable filter medium are used for absorption of coarse and fine dust in airconditioning and ventilation units. The filter medium is placed through metal separators inserted into a robust zinc-coated frame. On the air outlet side, there is a wire grid preventing release of the medium and ensuring high operating safety of the filter. The medium inserted between separators is fixed with two wire press springs on the air outlet side.
KS PR NEWFrame filter
Filtration class according to EN 779:2012
G2–G4, M5Delivery options
dimensions according to customer’s requirementsPossibility of regeneration
yes – replaceable filter medium
Technical dataUnit of
measure50/G2 50/G3 50/G4 50/M5 100/G2 100/G3 100/G4 100/M5 150/G2 150/G3 150/G4 150/M5
Nominal air flow
rate for dimensions
592 × 592 mm
m3/h 3,400 3,400 3,400 1,700 3,400 3,400 3,400 1,700 3,400 3,400 3,400 1,700
Mean separation (Am)
according to EN 779:2012 % 65 – 80 80 – 90 > 90 – 65 – 80 80 – 90 > 90 – 65 – 80 80 – 90 > 90 –
Efficiency Em (%)
according to EN 779:2012% – – – 40 – 60 – – – 40 – 60 – – – 40 – 60
Initial pressure loss at
nominal loadPa 55 80 120 95 60 90 140 85 60 90 150 91
Recommended final
pressure lossPa 250 250 250 400 250 250 250 250 250 250 250 400
Maximum thermal
resistance˚C 90 100 100 100 100 100 100 100 100 100 100 100
Field of applicationVentilation and air-conditioning of production halls, office buildings and assembly rooms, telecommunication central offices, health facilities, airport terminals, etc.
MaterialSynthetic fibre
Waste disposalLandfilling or incineration in authorised incineration plants.
43KS PL-25Frame filter
Pressure loss diagram G2 G3 G4 M5
Pre
ssur
e lo
ss [P
a]
150
120
90
60
30
0 1 000 2 000 3 000 4 000
Volume flow rate [m3/h/m2]
Filtration class according to EN 779:2012
G2, G3, G4, M5Delivery options
dimensions according to customer’s requirementsPossibility of regeneration
yes, partial
Filter propertiesA cut-to-size element of the filter medium from synthetic fibres is inserted into a solid and stable frame from zinc-coated sheet metal. On the clean air intake side, the filter medium is covered with a zinc-coated protective grid. The medium is fixed by means of a steel clamp on the inlet side of the filter. Depending on the type of filtration, it is possible to supply the KS PL filters with glass fibre medium or with a special medium KS CARB with activated carbon.
Field of applicationOverhead air-conditioning units and intake devices.
MaterialSynthetic fibre
Waste disposalLandfilling or incineration in authorised incineration plants.
Technical data Unit of measure KS PL-25 KS PL-25 KS PL-25 KS PL-25
Filtration class according to EN 779:2012 – G2 G3 G4 M5
Mean separation (Am) according to EN 779:2012 % 65 – 80 80 – 90 > 90 –
Efficiency (Em) according to EN 779:2012 % – – – 40 – 60
Nominal air flow rate m3/h/m2 3,400 3,400 3,400 3,400
Initial pressure loss at nominal load Pa 55 80 110 186
Recommended final pressure loss Pa 250 250 250 250
Maximum thermal resistance ˚C 100 100 100 100
FILT
ER M
EDIA
PO
CK
ET
FILT
ERS
FRA
ME
FIL
TER
S
CO
MPA
CT
FILT
ERS
AB
SOLU
TE F
ILTE
RS
FOR
MIC
RO
PAR
TIC
LES
CO
MP
ON
ENTS
FO
R
CLE
AN
RO
OM
SFI
LTER
UN
ITS
FOR
AIR
H
AN
DLI
NG
PIP
ELIN
ES
MO
UN
TIN
G F
RA
ME
SA
DSO
RP
TIO
N F
ILTE
RS
WIT
H A
CTI
VATE
D C
AR
BO
NA
CC
ES
SOR
IES
44
As
part
of o
ur p
rogr
amm
e of
con
tinuo
us im
prov
emen
t, K
S K
lima-
Serv
ice,
a.s
. re
serv
es th
e rig
ht to
cha
nge
the
spec
ifica
tion
with
out p
rior n
otic
e. 0
2/2
014
KS PL-5Double-sided planar frame filter
Pressure loss diagram PL-5
Pre
ssur
e lo
ss [P
a]
100
80
60
40
20
0 1 500 3 000 4 500 6 000
Volume flow rate [m3/h/m2]
Filtration class according to EN 779:2012
G2Delivery options
dimensions according to customer’s requirementsPossibility of regeneration
yes, partial
Filter propertiesThe filter media KS 15/60 is sewn on sides to make a bag that is inserted on a wire frame (5 mm).
Field of applicationOverhead and wall-mounted air-conditioning units and intake filter systems. Fancoil devices, door screens
MaterialSynthetic fibre
Waste disposalLandfilling or incineration in authorised incineration plants.
Technical data Unit of measure KS PL-5
Filtration class according to EN 779:2012 – G2
Mean separation (Am) according to EN 779:2012 % 65 – 80
Nominal air flow rate m3/h/m2 5,400
Initial pressure loss at nominal load Pa 10
Recommended final pressure loss Pa 40
Maximum thermal resistance ˚C 100
45KS PL-10 and KS PL-20Planar frame filters for FANCOIL
Pressure loss diagram G2 G3 G4
110
Pre
ssur
e lo
ss [P
a]
100
80
60
40
20
0 1 500 3 000 4 500
Volume flow rate [m3/h/m2]
Filtration class according to EN 779:2012
G2, G3, G4Delivery options
dimensions according to customer’s requirementsPossibility of regeneration
yes, partial
Filter propertiesA cut-to-size element of the filter media of suitable filtration class is inserted into a solid and stable frame from zinc-coated sheet metal.
Field of applicationOverhead and wall-mounted air-conditioning units and intake filter systems. Fancoil units.
MaterialSynthetic fibre
Waste disposalLandfilling or incineration in authorised incineration plants.
Technical data Unit of measure KS PL-10 a KS PL-20 KS PL-10 a KS PL-20 KS PL-10 a KS PL-20
Filtration class according to EN 779:2012 – G2 G3 G4
Mean separation (Am) according to EN 779:2012 % 65 – 80 80 – 90 > 90
Nominal air flow rate m3/h/m2 3,400 3,400 3,400
Initial pressure loss at nominal load Pa 55 80 110
Recommended final pressure loss Pa 250 250 250
Maximum thermal resistance ˚C 100 100 100
FILT
ER M
EDIA
PO
CK
ET
FILT
ERS
FRA
ME
FIL
TER
S
CO
MPA
CT
FILT
ERS
AB
SOLU
TE F
ILTE
RS
FOR
MIC
RO
PAR
TIC
LES
CO
MP
ON
ENTS
FO
R
CLE
AN
RO
OM
SFI
LTER
UN
ITS
FOR
AIR
H
AN
DLI
NG
PIP
ELIN
ES
MO
UN
TIN
G F
RA
ME
SA
DSO
RP
TIO
N F
ILTE
RS
WIT
H A
CTI
VATE
D C
AR
BO
NA
CC
ES
SOR
IES
46
As
part
of o
ur p
rogr
amm
e of
con
tinuo
us im
prov
emen
t, K
S K
lima-
Serv
ice,
a.s
. re
serv
es th
e rig
ht to
cha
nge
the
spec
ifica
tion
with
out p
rior n
otic
e. 0
2/2
014
KS PL-FOne-sided planar frame filter for FANCOIL
Pressure loss diagram KS PL-F
Pre
ssur
e lo
ss [P
a]
100
80
60
40
20
0 1 500 3 000 4 500 6 000
Volume flow rate [m3/h/m2]
Filtration class according to EN 779:2012
G2Delivery options
dimensions according to customer’s requirementsPossibility of regeneration
yes, partial
Filter propertiesThe filtration medium type KS 15/60 is attached to a wire frame (5 mm) by stitching.
Field of applicationOverhead and wall-mounted air-conditioning units and intake filter systems. Fancoil units.
MaterialSynthetic fibre
Waste disposalLandfilling or incineration in authorised incineration plants.
Technical data Unit of measure KS PL-F
Filtration class according to EN 779:2012 – G2
Mean separation (Am) according to EN 779:2012 % 65 – 80
Nominal air flow rate m3/h/m2 5,400
Initial pressure loss at nominal load Pa 7
Recommended final pressure loss Pa 40
Maximum thermal resistance ˚C 100
47KS W 50, G4; KS W 100, G4 and KS W 150, G4Frame filters "Z-LINE"
Pressure loss diagram KS W 50/4, KS W 150/4 KS W 100/4
Pre
ssur
e lo
ss [P
a]
100
80
60
40
20
0 1,000 2,000 3,000 4,000
Volume flow rate [m3/h] for dimensions 592 × 592 mm
Filtration class according to EN 779:2012
G4Delivery options
standard EURO line, non-standard dimensions according to customer’s requirementsPossibility of regeneration
no
Filter propertiesFrame filters KS-W are made of folded synthetic filter media. The folded medium is mounted in a solid cardboard frame with a cardboard grid and sealed with a hot-melt system. Due to high flow rates, the filter is reinforced with a spacer pad. Possibility to manufacture with a zinc-coated or plastic frame.
Field of applicationAssembly rooms, laboratories, hospitals
MaterialSynthetic fibre
Waste disposalLandfilling or incineration in authorised incineration plants.
Technical data Unit of measure KS W 50/4 KS W 100/4 KS W 150/4
Filtration class according to EN 779:2012 – G4 G4 G4
Mean separation (Am) according to EN 779:2012 % > 90 > 90 > 90
Nominal air flow rate for a filter element
of dimensions 592 × 592 mmm3/h 3,400 3,400 3,400
Initial pressure loss at nominal load Pa 65 55 65
Recommended final pressure loss Pa 300 300 300
Maximum thermal resistance ˚C 70 70 70
FILT
ER M
EDIA
PO
CK
ET
FILT
ERS
FRA
ME
FIL
TER
S
CO
MPA
CT
FILT
ERS
AB
SOLU
TE F
ILTE
RS
FOR
MIC
RO
PAR
TIC
LES
CO
MP
ON
ENTS
FO
R
CLE
AN
RO
OM
SFI
LTER
UN
ITS
FOR
AIR
H
AN
DLI
NG
PIP
ELIN
ES
MO
UN
TIN
G F
RA
ME
SA
DSO
RP
TIO
N F
ILTE
RS
WIT
H A
CTI
VATE
D C
AR
BO
NA
CC
ES
SOR
IES
48
As
part
of o
ur p
rogr
amm
e of
con
tinuo
us im
prov
emen
t, K
S K
lima-
Serv
ice,
a.s
. re
serv
es th
e rig
ht to
cha
nge
the
spec
ifica
tion
with
out p
rior n
otic
e. 0
2/2
014
KS W 50, M5; KS W 100, M5 and KS W 150, M5Frame filters "Z-LINE"
Pressure loss diagram KS W 50/5 KS W 100/5 KS W 150/5
Pre
ssur
e lo
ss [P
a]
100
80
60
40
20
0 1,000 2,000 3,000 4,000
Volume flow rate [m3/h] for dimensions 592 × 592 mm
Filtration class according to EN 779:2012
M5Delivery options
standard EURO line, non-standard dimensions according to customer’s requirementsPossibility of regeneration
no
Filter propertiesFrame filters KS-W are made of folded synthetic filter media. The folded medium is mounted in a solid cardboard frame with a cardboard grid and sealed with a hot-melt system. Due to high flow rates, the filter is reinforced with a spacer pad. Possibility to manufacture with a zinccoated or plastic frame.
Field of applicationAssembly rooms, laboratories, hospitals
MaterialSynthetic fibre
Waste disposalLandfilling or incineration in authorised incineration plants.
Technical data Unit of measure KS W 50/5 KS W 100/5 KS W 150/5
Filtration class according to EN 779:2012 – M5 M5 M5
Mean efficiency (Em) for 0.4 μm particles
according to EN 779:2012% 40 – 60 40 – 60 40 – 60
Nominal air flow rate for a filter element
of dimensions 592 × 592 mmm3/h 3,400 3,400 3,400
Initial pressure loss at nominal load Pa 90 80 75
Recommended final pressure loss Pa 300 300 300
Maximum thermal resistance ˚C 70 70 70
49KS W 50, M6Frame filter „Z-LINE”
Pressure loss diagram KS W 50, M6
Filtration class according to EN 779:2012
M6Delivery options
standard EURO line, non-standard dimensions according to customer’s requirementsPossibility of regeneration
no
Filter propertiesFrame filters KS-W are made of folded synthetic filter media. The folded medium is mounted in a solid cardboard frame with a cardboard grid and sealed with a hot-melt system. Due to high flow rates, the filter is reinforced with a spacer pad. Possibility to manufacture with a zinccoated or plastic frame.
Field of applicationAssembly rooms, laboratories, hospitals
MaterialSynthetic fibre
Waste disposalLandfilling or incineration in authorised incineration plants.
Technical data Unit of measure KS W 50, M6
Filtration class according to EN 779:2012 – M6
Mean efficiency (Em) for 0.4 μm particles
according to EN 779:2012% 60 – 80
Nominal air flow rate for a filter element 592 × 592 mm m3/h 2,380
Initial pressure loss at nominal load Pa 125
Recommended final pressure loss Pa 300
Maximum thermal resistance ˚C 70
Pre
ssur
e lo
ss [P
a]
200
160
120
80
40
0 1 000 2 000 3 000 4 000
Volume flow rate [m3/h] for dimensions 592 × 592 mm
FILT
ER M
EDIA
PO
CK
ET
FILT
ERS
FRA
ME
FIL
TER
S
CO
MPA
CT
FILT
ERS
AB
SOLU
TE F
ILTE
RS
FOR
MIC
RO
PAR
TIC
LES
CO
MP
ON
ENTS
FO
R
CLE
AN
RO
OM
SFI
LTER
UN
ITS
FOR
AIR
H
AN
DLI
NG
PIP
ELIN
ES
MO
UN
TIN
G F
RA
ME
SA
DSO
RP
TIO
N F
ILTE
RS
WIT
H A
CTI
VATE
D C
AR
BO
NA
CC
ES
SOR
IES
50
As
part
of o
ur p
rogr
amm
e of
con
tinuo
us im
prov
emen
t, K
S K
lima-
Serv
ice,
a.s
. re
serv
es th
e rig
ht to
cha
nge
the
spec
ifica
tion
with
out p
rior n
otic
e. 0
2/2
014
KS W 50, F7Frame filter „Z-LINE”
Pressure loss diagram KS W 50, F7
Pre
ssur
e lo
ss [P
a]
200
160
120
80
40
0 1 000 2 000 3 000 4 000
Volume flow rate [m3/h] for dimensions 592 × 592 mm
Filtration class according to EN 779:2012
F7Delivery options
standard EURO line, non-standard dimensions according to customer’s requirementsPossibility of regeneration
no
Filter propertiesFrame filters KS-W are made of folded synthetic filter media. The folded medium is mounted in a solid cardboard frame with a cardboard grid and sealed with a hot-melt system. Due to high flow rates, the filter is reinforced with a spacer pad. Possibility to manufacture with a zinccoated or plastic frame.
Field of applicationAssembly rooms, laboratories, hospitals
MaterialSynthetic fibre
Waste disposalLandfilling or incineration in authorised incineration plants.
Technical data Unit of measure KS W 50, F7
Filtration class according to EN 779:2012 – F7
Mean efficiency (Em) for 0.4 μm particles
according to EN 779:2012% 80 – 90
Nominal air flow rate for a filter element 592 × 592 mm m3/h 2,380
Initial pressure loss at nominal load Pa 220
Recommended final pressure loss Pa 300
Maximum thermal resistance ˚C 70
51KS MPP 96/5Frame filter with polypropylene medium
Pressure loss diagram KS MPP 96/5
Pre
ssur
e lo
ss [P
a]
200
160
120
80
40
0 1 000 2 000 3 000 4 000
Volume flow rate 592 × 592 × 96 mm [m3/h]
Filtration class according to EN 779:2012
M5Delivery options
dimensions according to the customer’s requirements, frame filter depth from 30 to 96 mmPossibility of regeneration
no
Filter propertiesThe filter medium is mounted into a solid plastic or cardboard frame and sealed using a “hot-melt” system. The filter materials of various filtration classes differ in colour.
Large filtration area – long service life• high air flow rate• new, “mini-pleat” type filter medium from a 100%
polypropylene
High mechanical strength of the filter• easy mounting and dismounting in air-handling
devices• high dust accumulation capacity
Low structural depth• stable frame from hardened cardboard or plastic• low weight, low transport volume• fully incinerable filter
Field of applicationThey are used as the second or the only filtration stage in all air-conditioning and air-handling units.
MaterialMinipleat medium from polypropylene
Waste disposalIncineration in appropriate incinerators.
Technical data Unit of measure KS MPP 96/5
Filtration class according to EN 779:2012 – M5
Mean separation (Am) according to EN 779:2012 % –
Mean efficiency (Em) for 0.4 μm particles according to EN 779:2012 % 40 – 60
Nominal air flow rate for a filter element 592 × 592 × 96 mm m3/h 3,400
Initial pressure loss at nominal load Pa 75
Recommended final pressure loss Pa 380
Maximum thermal resistance ˚C 70
FILT
ER M
EDIA
PO
CK
ET
FILT
ERS
FRA
ME
FIL
TER
S
CO
MPA
CT
FILT
ERS
AB
SOLU
TE F
ILTE
RS
FOR
MIC
RO
PAR
TIC
LES
CO
MP
ON
ENTS
FO
R
CLE
AN
RO
OM
SFI
LTER
UN
ITS
FOR
AIR
H
AN
DLI
NG
PIP
ELIN
ES
MO
UN
TIN
G F
RA
ME
SA
DSO
RP
TIO
N F
ILTE
RS
WIT
H A
CTI
VATE
D C
AR
BO
NA
CC
ES
SOR
IES
52
As
part
of o
ur p
rogr
amm
e of
con
tinuo
us im
prov
emen
t, K
S K
lima-
Serv
ice,
a.s
. re
serv
es th
e rig
ht to
cha
nge
the
spec
ifica
tion
with
out p
rior n
otic
e. 0
2/2
014
KS MPP 96/6 and KS MPP 96/7Frame filters with polypropylene medium
Pressure loss diagram KS MPP 96/6 KS MPP 96/7
Pre
ssur
e lo
ss [P
a]
200
160
120
80
40
0 1 000 2 000 3 000 4 000
Volume flow rate [m3/h] for dimensions 592 × 592 × 96 mm
Filtration class according to EN 779:2012
M6, F7Delivery options
dimensions according to the customer’s requirements, frame filter depth from 30 to 96 mmMožnost regenerace
no
Filter propertiesThe filter medium is mounted into a solid plastic or cardboard frame and sealed using a “hot-melt” system. The filter materials of various filtration classes differ in colour.
Large filtration area – long service life• high air flow rate• new, “mini-pleat” type filter medium from a 100%
polypropylene
High mechanical strength of the filter• easy mounting and dismounting in air-handling
devices• high dust accumulation capacity
Low structural depth• stable frame from hardened cardboard or plastic• low weight, low transport volume• fully incinerable filter
Field of applicationThey are used for absorption of fine dust in assembly rooms, health facilities, laboratories, etc.
MaterialMinipleat medium from polypropylene
Waste disposalIncineration in appropriate incinerators.
Technical data Unit of measure KS MPP 96/6 KS MPP 96/7
Filtration class according to EN 779:2012 – M6 F7
Mean efficiency (Em) for 0.4 μm particles
according to EN 779:2012% 60 – 80 80 – 90
Nominal air flow rate for a filter element 592 × 592 × 96 mm m3/h 3,400 3,400
Initial pressure loss at nominal load Pa 95 140
Recommended final pressure loss Pa 380 380
Maximum thermal resistance ˚C 70 70
53KS MPP 96/8Frame filter with polypropylene medium
Pressure loss diagram KS MPP 96/8
Pre
ssur
e lo
ss [P
a]
200
160
120
80
40
0 1 000 2 000 3 000 4 000
Volume flow rate [m3/h] for dimensions 592 × 592 × 96 mm
Filtration class according to EN 779:2012
F8Delivery options
dimensions according to the customer’s requirements, frame filter depth from 30 to 96 mmPossibility of regeneration
no
Filter propertiesThe filter medium is mounted into a solid plastic or cardboard frame and sealed using a “hot-melt” system. The filter materials of various filtration classes differ in colour.
Large filtration area – long service life• high air flow rate• new, “mini-pleat” type filter medium from a 100%
polypropylene
High mechanical strength of the filter• easy mounting and dismounting in air-handling
devices• high dust accumulation capacity
Low structural depth• stable frame from hardened cardboard or plastic• low weight, low transport volume•fully incinerable filter
Field of applicationThey are used for absorption of fine dust in electrotechnical industry, airports, etc.
Technical data Unit of measure KS MPP 96/8
Filtration class according to EN 779:2012 – F8
Mean efficiency (Em) for 0.4 μm particles
according to EN 779:2012% 90 – 95
Nominal air flow rate for a filter element 592 × 592 × 96 mm m3/h 3,400
Initial pressure loss at nominal load Pa 165
Recommended final pressure loss Pa 380
Maximum thermal resistance ˚C 70
MaterialMinipleat medium from polypropylene
Waste disposalIncineration in appropriate incinerators.
FILT
ER M
EDIA
PO
CK
ET
FILT
ERS
FRA
ME
FIL
TER
S
CO
MPA
CT
FILT
ERS
AB
SOLU
TE F
ILTE
RS
FOR
MIC
RO
PAR
TIC
LES
CO
MP
ON
ENTS
FO
R
CLE
AN
RO
OM
SFI
LTER
UN
ITS
FOR
AIR
H
AN
DLI
NG
PIP
ELIN
ES
MO
UN
TIN
G F
RA
ME
SA
DSO
RP
TIO
N F
ILTE
RS
WIT
H A
CTI
VATE
D C
AR
BO
NA
CC
ES
SOR
IES
54
As
part
of o
ur p
rogr
amm
e of
con
tinuo
us im
prov
emen
t, K
S K
lima-
Serv
ice,
a.s
. re
serv
es th
e rig
ht to
cha
nge
the
spec
ifica
tion
with
out p
rior n
otic
e. 0
2/2
014
KS MPP 96/9Frame filter with polypropylene medium
Pressure loss diagram KS MPP 96/9
Pre
ssur
e lo
ss [P
a]
200
160
120
80
40
0 1 000 2 000 3 000 4 000
Volume flow rate [m3/h] for dimensions 592 × 592 × 96 mm
Filtration class according to EN 779:2012
F9Delivery options
dimensions according to the customer’s requirements, frame filter depth from 30 to 96 mmPossibility of regeneration
no
Filter propertiesThe filter medium is mounted into a solid plastic or cardboard frame and sealed using a “hot-melt” system. The filter materials of various filtration classes differ in colour.
Large filtration area – long service life• high air flow rate• new, “mini-pleat” type filter medium from a 100%
polypropylene
High mechanical strength of the filter• easy mounting and dismounting in air-handling
devices• high dust accumulation capacity
Low structural depth• stable frame from hardened cardboard or plastic• low weight, low transport volume• fully incinerable filter
Field of applicationThey are used for absorption of fine dust in electrotechnical industry, airports, etc.
Technical data Unit of measure KS MPP 96/9
Filtration class according to EN 779:2012 – F9
Mean efficiency (Em) for 0.4 μm particles
according to EN 779:2012% > 95
Nominal air flow rate for a filter element 592 × 592 × 96 mm m3/h 3,400
Initial pressure loss at nominal load Pa 195
Recommended final pressure loss Pa 380
Maximum thermal resistance ˚C 70
MaterialMinipleat medium from polypropylene
Waste disposalIncineration in appropriate incinerators.
55KS MA 12.5, KS MA 20, KS MA 25 and KS MA 45Frame filters – metal filter elements
Pressure loss diagram MA 12,5 MA 20 MA 25 MA 45
Pre
ssur
e lo
ss [P
a]
100
80
60
40
20
0 1 000 2 000 3 000 4 000
Volume flow rate [m3/h] for dimensions 592 × 592 mm
Filtration class according to EN 779:2012
G2, G3Delivery options
dimensions according to customer’s requirementsPossibility of regeneration
yes
Filter propertiesSeveral layers from a special aluminium intertwined medium is inserted into a U-section aluminium frame. The filter medium is protected from both sides by a solid aluminium expanded metal grid.
Field of applicationAbsorption of grease and oil aerosols in exhaust equipment in kitchens, bakeries, smoke houses, grill restaurants. Separation of the coarsest dust particles in foundries, metallurgical plants and the steel industry.
MaterialAluminium / stainless steel
Waste disposalLandfilling
Technical data Unit of measure MA 12,5 MA 20 MA 25 MA 45
Filtration class according to EN 779:2012 – G2 G3 G3 G3
Mean separation (Am) according to EN 779:2012 % 65 – 80 80 – 90 80 – 90 80 – 90
Nominal air flow rate for a filter element
of dimensions 592 × 592 mmm3/h 3,400 3,400 3,400 3,400
Initial pressure loss at nominal load Pa 32 45 56 80
Recommended final pressure loss Pa 100 130 130 200
Maximum thermal resistance ˚C 200 200 200 200
FILT
ER M
EDIA
PO
CK
ET
FILT
ERS
FRA
ME
FIL
TER
S
CO
MPA
CT
FILT
ERS
AB
SOLU
TE F
ILTE
RS
FOR
MIC
RO
PAR
TIC
LES
CO
MP
ON
ENTS
FO
R
CLE
AN
RO
OM
SFI
LTER
UN
ITS
FOR
AIR
H
AN
DLI
NG
PIP
ELIN
ES
MO
UN
TIN
G F
RA
ME
SA
DSO
RP
TIO
N F
ILTE
RS
WIT
H A
CTI
VATE
D C
AR
BO
NA
CC
ES
SOR
IES
56
As
part
of o
ur p
rogr
amm
e of
con
tinuo
us im
prov
emen
t, K
S K
lima-
Serv
ice,
a.s
. re
serv
es th
e rig
ht to
cha
nge
the
spec
ifica
tion
with
out p
rior n
otic
e. 0
2/2
014
KS GTA 200 and KS GTA 300Frame filters – filters for high temperatures
Pressure loss diagram GTA 200 GTA 300
Pre
ssur
e lo
ss [P
a]
150
120
90
60
30
0 250 500 750 1 000
Volume flow rate [m3/h] for dimensions 592 × 592 mm
Filtration class according to EN 779:2012
M6, G4Delivery options
480 (w) × 480 (h) × 14 (d) mm 592 (w) × 592 (h) × 14 (d) mm non-standard dimensions according to the customer’s resuirementsPossibility of regeneration
no
Filter propertiesThe filter medium of the special GTA 200 filter element for high temperatures is made of GLAS C material pressed into a double-sided protecting grid made of aluminium expanded metal. Thermal resistance up to 190 °C. The special GTA 300 filter elements for high temperatures are made of superfine glass fibre filter medium pressed in to a double-sided protecting grid made of aluminium expanded metal. Thermal resistance up to 300 °C.
Field of applicationGTA 300 is used for the separation of coarse and GTA 200 for the separation of fine dust in inlets into drying and painting equipment. Calcining equipment in the automotive industry.
MaterialGlass fibre + AL grid
Waste disposalLandfilling or incineration in authorised incineration plants after the separation of metal parts.
Technical data Unit of measure GTA 200 GTA 300
Filtration class according to EN 779:2012 – M6 G4
Mean separation (Am) according to EN 779:2012 % – > 90
Mean efficiency (Em) according to EN 779:2012 % 60 – 80 –
Nominal air flow rate for a filter element
of dimensions 592 × 592 mmm3/h 600 1,000
Initial pressure loss at nominal load Pa 130 36
Recommended final pressure loss Pa 500 250
Maximum thermal resistance ˚C 190 300
57MACROFALT and MACROPACFrame filters with folded filter medium
Pressure loss diagram MACROFALT G4, MACROPAC G4 MACROFALT M5, MACROPAC M5
Pre
ssur
e lo
ss [P
a]
100
80
60
40
20
0 1 000 2 000 3 000 4 000
Volume flow rate [m3/h] for dimensions 592 × 592 × 48 mm
Filtration class according to EN 779:2012
G4, M5Delivery options
592 (w) × 592 (h) mm 287 (w) × 592 (h) mm 490 (w) × 592 (h) mm 287 (w) × 287 (h) mmPossibility of regeneration
no
Filter propertiesThe MACROFALT and MACROPAC filter elements represent a revolutionary solution for separation of coarse and fine dust particles in the field of ventilation and air-conditioning. The filter pleat with elastic separators is inserted and sealed into a plastic frame. The filters feature a large filtration area and long service life.
Field of applicationThey are used as the first or the only filtration stage in all air-conditioning and air-handling units.
MaterialGlass fibre filter pleat
Waste disposalIncineration in appropriate incinerators
Technical data Unit of measure MACROFALT 592 × 592 × 48 mm MACROPAC 592 × 592 × 96 mm
Filtration class according to EN 779:2012 – G4 M5 G4 M5
Mean separation (Am) according to EN 779:2012 % >90 96 >90 96
Mean efficiency (Em) for 0.4 μm particles
according to EN 779:2012% – 40–60 – 40–60
Nominal air flow rate for a filter element
of dimensions 592 × 592 × 48 mmm3/h 3,400 3,400 3,400 3,400
Initial pressure loss at nominal load Pa 50 80 50 80
Recommended final pressure loss Pa 250 250 280 280
Maximum thermal resistance ˚C 80 80 80 80
FILT
ER M
EDIA
PO
CK
ET
FILT
ERS
FRA
ME
FIL
TER
S
CO
MPA
CT
FILT
ERS
AB
SOLU
TE F
ILTE
RS
FOR
MIC
RO
PAR
TIC
LES
CO
MP
ON
ENTS
FO
R
CLE
AN
RO
OM
SFI
LTER
UN
ITS
FOR
AIR
H
AN
DLI
NG
PIP
ELIN
ES
MO
UN
TIN
G F
RA
ME
SA
DSO
RP
TIO
N F
ILTE
RS
WIT
H A
CTI
VATE
D C
AR
BO
NA
CC
ES
SOR
IES
58 COMPACT FILTERS
Compact filter elements represent a modern and efficient solution of fine dust sepa-ration. The compact filter is made of a robust plastic frame with high minipleat filter pleats sealed inside. The unique structure of the filter allows to decrease significantly initial pressure losses. The filter has very low energy costs at full load.
The standard compact filters are suitable for use in all common mounting frames for pocket filters. All the filter parameters comply with requirements of EN 779 and EN 1822. The all-plastic design allows for smooth disposal - the filter is fully incinerable. It is best suited for use in all air-conditioning and ventilation devices as after-filters or pre-filters and as microparticle filters. It may be used in normal, as well as in special conditions with higher service life, safety, variability and thermal resistance require-ments.
The TMP and TMPC compact filters separate air impurities in air intake systems of rotary compressors and offer a perfect protection against pollution, corrosion and ero-sion of key turbine components. TMP filters are most suited for use in gas turbines, diesel units, compressors and air-conditioning devices in power plants, because they feature low pressure losses and long service life. Combined with the range of syn-thetic fibre pocket filters, they offer an optimum ratio of separation level to service life at the lowest pressure losses.
The compact filters are supplied in the three designs: KS FP V3 in filtration classes M6 – F9 and KS FP in filtration classes M6 – F9 and E10 – H13.
A special design of the KS TMP and KS TMPC filters is offered in filtration classes from M6 to E10.
59KS FP M6-F9Compact filters
Pressure loss diagram M6 F7 F8 F9
Filtration class according to EN 779:2012
M6, F7, F8, F9Delivery options
592 (w) × 592 (h) × 300 (d) mm 287 (w) × 592 (h) × 300 (d) mm 490 (w) × 592 (h) × 300 (d) mm 287 (w) × 287 (h) × 300 (d) mmPossibility of regeneration
no
Filter propertiesThe compact filter elements represent a modern and efficient solution of dine dust separation. The glass fibre medium (special filter paper) forms V-shaped pleats and is inserted into a plastic frame. An excellent output/ price ratio.
Field of applicationIn all air-conditioning and ventilation devices as afterfilters or pre-filters for microparticles.
MaterialA glass submicr. filter paper, frame: halogen-free recycled polystyrene.
Waste disposalIncineration without emissions of harmful substances.
Technical data Unit of measure KS FP
Filtration class according to EN 779:2012 – M6 F7 F8 F9
Mean efficiency level (gravimetric) % 98 99 99 ~100
Mean efficiency level (atmospheric) % 60-80 80-90 90-95 >95
Nominal air flow rate for a filter element
of dimensions 592 × 592 × 300 mmm3/h 3,400 3,400 3,400 3,400
Initial pressure loss at nominal load Pa 75 80 90 98
Recommended final pressure loss Pa 450 450 450 450
Maximum thermal resistance ˚C NT < 75; HT < 120
NT: standard temperature; HT: special design for higher temperature (not supplied with the KS FP M6 model)
Pre
ssur
e lo
ss [P
a]
100
80
60
40
20
0 1 000 2 000 3 000 4 000
Volume flow rate [m3/h]
for dimensions 592 × 592 × 300 mm
FILT
ER M
EDIA
PO
CK
ET
FILT
ERS
FRA
ME
FILT
ERS
CO
MP
AC
T FI
LTE
RS
AB
SOLU
TE F
ILTE
RS
FOR
MIC
RO
PAR
TIC
LES
CO
MP
ON
ENTS
FO
R
CLE
AN
RO
OM
SFI
LTER
UN
ITS
FOR
AIR
H
AN
DLI
NG
PIP
ELIN
ES
MO
UN
TIN
G F
RA
ME
SA
DSO
RP
TIO
N F
ILTE
RS
WIT
H A
CTI
VATE
D C
AR
BO
NA
CC
ES
SOR
IES
60
As
part
of o
ur p
rogr
amm
e of
con
tinuo
us im
prov
emen
t, K
S K
lima-
Serv
ice,
a.s
. re
serv
es th
e rig
ht to
cha
nge
the
spec
ifica
tion
with
out p
rior n
otic
e. 0
2/2
014
KS FP V3Compact filter
Pressure loss diagram M6 F7 F9
Filtration class according to EN 779:2012
M6, F7, F9Delivery options
592 (w) × 287 (h) × 292 (d) mm 592 (w) × 490 (h) × 292 (d) mm 592 (w) × 592 (h) × 292 (d) mm 287 (w) × 287 (h) × 292 (d) mmPossibility of regeneration
no
Filter propertiesThe design of the compact filter with 3 cassettes V3 achieves lower initial pressure losses compared with the 4 cassette compact filters type. The filtering area remains the same thanks to a higher minipleat. When these filters are used as replacement for pocket filters, the longer time of use with lower pressure losses guarantee substantial savings of energy costs. Handles situated in the upper part of the compact filter enable easier handling and elimination of damage to the filter medium.
Field of applicationPre-filtering and main filtering of fine dust particles and aerosols in filtration classes F6 - F9 in all air-handling devices in office buildings, hospitals, computer centres, pharmaceuticals production plants, precision mechanics and food-processing plants.
Materiál
Glass submicr. filter paper, robust plastic frame, copolymer, thermoplastic separators
Waste disposalIncineration without emissions of harmful substances.
Technical data Unit of measure KS FP V3
Filtration class according to EN 779:2012 – M6 F7 F9
Mean efficiency level (gravimetric) % 98 99 ~100
Mean efficiency level (atmospheric) % 70 82 96
Nominal air flow rate for a filter element
of dimensions 592 × 592 × 292 mmm3/h 4,250 4,250 4,250
Initial pressure loss at nominal load Pa 93 113 132
Recommended final pressure loss Pa 450 450 450
Operating conditions max. relativ. air humidity 100 %, thermally resistant to 65 °C, for a short period max. up to. 80 °C
Pre
ssur
e lo
ss [P
a]
150
120
90
60
30
0 1 000 2 000 3 000 4 000 5 000
Volume flow rate [m3/h]
for dimensions 592 × 592 × 292 mm
61KS FP E10-H13Compact filter – compact filter elements
Pressure loss diagram E10 E11 E12 H13
Filtration class according to EN 1822:2010
E10, E11, E12, H13Delivery options
592 (w) × 592 (h) × 300 (d) mm 287 (w) × 592 (h) × 300 (d) mm 490 (w) × 592 (h) × 300 (d) mm 287 (w) × 287 (h) × 300 (d) mmPossibility of regeneration
no
Filter propertiesCompact filter elements in filtration classes E10, E11, E12, H13 represent a new microparticles filtration solution. Advantages: high flow rate and standard dimensions, large filtering area 20 m2, excellent dust absorbing capacity, optimum distribution of air flow - energy savings, possibility to use the filters in standard frames in air-conditioning units with high cleanliness demands.
Field of applicationIn all air-conditioning and ventilation devices as afterfilters or pre-filters for microparticles.
MaterialGlass submicr. filter paper, halogen-free recycled polystyrene
Waste disposalIncineration without emissions of harmful substances.
Technical data Unit of measure KS FP
Filtration class according to EN 1822:2010 – E10 E11 E12 H13
Total value for MPPS particles according
to EN 1822:2010% >− 85 >− 95 >− 99.5 >− 99.95
Nominal air flow rate for a filter element
of dimensions 592 × 592 × 300 mmm3/h 3,400 3,000 3,000 2,000
Initial pressure loss at nominal load Pa 140 155 260 180
Recommended final pressure loss Pa 450 450 450 450
Maximum thermal resistance ˚C NT < 75; HT < 120
NT: standard temperature; HT: special design for higher temperature (not supplied with the KS FP M6 model
Pre
ssur
e lo
ss [P
a]
300
250
200
150
100
50
0 1 000 2 000 3 000 4 000 5 000
Volume flow rate [m3/h] for dimensions 592 × 592 × 300 mm
FILT
ER M
EDIA
PO
CK
ET
FILT
ERS
FRA
ME
FILT
ERS
CO
MP
AC
T FI
LTE
RS
AB
SOLU
TE F
ILTE
RS
FOR
MIC
RO
PAR
TIC
LES
CO
MP
ON
ENTS
FO
R
CLE
AN
RO
OM
SFI
LTER
UN
ITS
FOR
AIR
H
AN
DLI
NG
PIP
ELIN
ES
MO
UN
TIN
G F
RA
ME
SA
DSO
RP
TIO
N F
ILTE
RS
WIT
H A
CTI
VATE
D C
AR
BO
NA
CC
ES
SOR
IES
62
As
part
of o
ur p
rogr
amm
e of
con
tinuo
us im
prov
emen
t, K
S K
lima-
Serv
ice,
a.s
. re
serv
es th
e rig
ht to
cha
nge
the
spec
ifica
tion
with
out p
rior n
otic
e. 0
2/2
014
TMP elements for gas turbines M6-F7Compact filter
Pressure loss diagram F7 M6
Filtration class according to EN 779:2012
M6, F7Delivery options
592 (w) × 592 (h) × 300 (d) mm 287 (w) × 592 (h) × 300 (d) mm 490 (w) × 592 (h) × 300 (d) mm 402 (w) × 592 (h) × 300 (d) mmPossibility of regeneration
no
Filter propertiesCompact filter elements TMP consist of 4V elements sealed on both sides into a plastic frame using polyurethane. The double-sided sealing of the filter pleat makes the filter resistant to dripping condensate and provides a long service life in extreme conditions. The TMP compact filter elements separate air impurities in air intake systems of rotary compressors and offer a perfect protection against pollution, corrosion and erosion of key turbine components.
Field of applicationGas turbines, plate power units, compressors and airconditioning units in power plants.
MaterialGlass submicr. filter paper, halogen-free recycled polystyrene
Waste disposalIncineration in appropriate incinerators.
Technical data Unit of measure KS TMP
Filtration class according to EN 779:2012 – M6 F7
Mean efficiency level (gravimetric) % > 98 > 99
Mean efficiency level (atmospheric) % 60–80 80–90
Nominal air flow rate VR / VN for a filter element
of dimensions 592 × 592 × 300 mmm3/h 3,400 / 4,250 3,400 / 4,250
Initial pressure loss at nominal load Pa 78 / 105 80 / 115
Recommended final pressure loss Pa 450 450
Maximum thermal resistance ˚C <− 70
Pre
ssur
e lo
ss [P
a]
100
80
60
40
20
0 1 000 2 000 3 000 4 000
Volume flow rate [m3/h]
for dimensions 592 × 592 × 300 mm
63TMP, TMPC elements for gas turbines F8-E10Compact filters
Pressure loss diagram F8 F9 E10
Filtration class according to EN 779:2012, EN 1822:2010
F8, F9, E10Delivery options
592 (w) × 592 (h) × 300 (d) mm 287 (w) × 592 (h) × 300 (d) mm 490 (w) × 592 (h) × 300 (d) mm 402 (w) × 592 (h) × 300 (d) mmPossibility of regeneration
no
Filter propertiesCompact filter elements TMPC consist of 4V elements sealed on both sides into a plastic frame using polyurethane. The double-sided sealing of the filter pleat makes the filter resistant to dripping condensate and provides a long service life in extreme conditions. The maximally open intake areas, minimum pressure losses and larger areas of the filter medium maximise the dust accumulation capacity. The fully sealed HEPA version of the TMPC filter element has conical cover plates for optimum water outflow. The TMPC ultrafilters meet requirements laid by the youngest generation of ultra-efficient gas turbines that are very sensible to submicron particles. Due to higher demands and higher efficiency levels, these ultrafilters are supplied only in the HEPA version.
Field of applicationGas turbines, plate power units, compressors and airconditioning units in power plants.
MaterialGlass submicr. filter paper, halogen-free recycled polystyrene
Waste disposalIncineration in appropriate incinerators.
Technical data Unit of measure KS TMP KS TMPC
Filtration class according to EN 779:2012 / EN 1822:2010 – F8 F9 E10
Mean efficiency level (gravimetric) % 99 ~100 ~100
Mean efficiency level (atmospheric) % 90-95 >95 98
Nominal air flow rate VR / VN for a filter element
of dimensions 592 × 592 × 300 mmm3/h 3,400 / 4,250 3,400 / 4,250 3,000 / 3,400
Initial pressure loss at nominal loadVR / VN Pa 90 / 130 98 / 140 140
Recommended final pressure loss Pa 450 450 450
Maximum thermal resistance ˚C <− 70
Pre
ssur
e lo
ss [P
a]
150
120
90
60
30
0 1 000 2 000 3 000 4 000
Volume flow rate [m3/h]
for dimensions 592 × 592 × 300 mm
FILT
ER M
EDIA
PO
CK
ET
FILT
ERS
FRA
ME
FILT
ERS
CO
MP
AC
T FI
LTE
RS
AB
SOLU
TE F
ILTE
RS
FOR
MIC
RO
PAR
TIC
LES
CO
MP
ON
ENTS
FO
R
CLE
AN
RO
OM
SFI
LTER
UN
ITS
FOR
AIR
H
AN
DLI
NG
PIP
ELIN
ES
MO
UN
TIN
G F
RA
ME
SA
DSO
RP
TIO
N F
ILTE
RS
WIT
H A
CTI
VATE
D C
AR
BO
NA
CC
ES
SOR
IES
64 ABSOLUTE FILTERS FOR MICROPARTICLES
The absolute filters for microparticles in filtration classes E10 – H14 and U15 – U17 are used in intake, circulating and exhaust air devices with the highest air cleanliness and sterility requirements. By using ultra-soft glass microfibres and precise folding, the EPA, HEPA and ULPA filters achieve high submicron particles separation capaci-ties and guarantee a controlled air flow (laminar flow).
The frame for different types of EPA, HEPA and ULPA filters may be made from aluminium, multi-layer wood, MDF, stainless sheet metal or zinc-coated sheet metal. Separators of EPA, HEPA and ULPA filters are made using the so-called MINIPLEAT technology, when separators consist of a thermally processed melt adhesive. In spe-cial cases, the technology of inserted aluminium separators is used too. Seals of EPA, HEPA and ULPA filters is from a special section made from EPDM sponge rubber with closed surface. Form of the seal: flat, semi-circular, double-edged. Flat and gel seals, U-section seals and seals for high temperatures.
EPA, HEPA and ULPA filters are used in a wide range of applications. They are used in industrial processes (microelectronics, pharmaceutical industry, food-processing in-dustry, health care, optics, microbiology, etc.) - operating rooms and hospitals, clean work tables (laminar flow boxes) - ceiling outlets (extensions for clean rooms) and so-called fan filter units - treatment of hazardous substances such as asbestos, heavy metals and carcinogenic dusts - nuclear energy plants and nuclear research, etc. Hepa filters are manufactured in several variants: KS BESTFIL, Ultrafilter CR, Ultrafilter N, absolute filters JP, JK, JG, JKG.
65KS BESTFIL (HEPA)Absolute filters for microparticles – EPA, HEPA, ULPA
Filtration class according to EN 1822:2010
E10 – H14Delivery options
frame widths: 46, 54, 69, 75, 78, 150, 292 mmPossibility of regeneration
no
Filter frameThe standard frame (hardened hydrophobic MDF); zinc-coated sheet metal, multilayer wooden board, aluminium or stainless steel if requested.
SeparatorsSeparators are made using the so-called MINIPLEAT technology, when separators consist of a thermally processed melt adhesive. In special cases, the technology of inserted aluminium separators may be used too.
Sealing of the filter pleat in the frameTwo-component polyurethane sealant.
SealsA special section from EPDM sponge rubber with closed surface. Form and type of the seal: flat, semi-circular, double-edged. Gel seals, U-section seals and seals for high temperatures.
Quality, defectoscopy, SCAN TEST*All filters - oil mist seepage test for faultlessness, Scantest with a test certificate for extra charge.
Field of applicationIn areas with the highest demands for air cleanliness. The health sector - laminar ceilings, extensions for clean rooms, pharmaceutics, microbiology, production of CDs, food-processing industry.
Materialhydrophobic filter paper
Waste disposalIncineration in appropriate incinerators.
* SCAN TEST = computer controlled test of the filter medium with a laser particle counter.
Advantages of KS Klima-Service• 100% proper production of KS MIKRO
• own automatic folding of medium with parameters set according to the customer’s requirements
• automatic sealing of the filter pleat into the frame using polyurethane sealant
• automatic application of the sealant on the intake, outlet or both sides of the filter according to the customer’s requirements
• own non-destructive testing and efficiency measurement in our own scanning apparatus including a test certificate according to EN 1822:2010
FILT
ER M
EDIA
PO
CK
ET
FILT
ERS
FRA
ME
FILT
ERS
CO
MPA
CT
FILT
ERS
AB
SO
LUTE
FIL
TER
S FO
R M
ICR
OP
AR
TIC
LES
CO
MP
ON
ENTS
FO
R
CLE
AN
RO
OM
SFI
LTER
UN
ITS
FOR
AIR
H
AN
DLI
NG
PIP
ELIN
ES
MO
UN
TIN
G F
RA
ME
SA
DSO
RP
TIO
N F
ILTE
RS
WIT
H A
CTI
VATE
D C
AR
BO
NA
CC
ES
SOR
IES
66
As
part
of o
ur p
rogr
amm
e of
con
tinuo
us im
prov
emen
t, K
S K
lima-
Serv
ice,
a.s
. re
serv
es th
e rig
ht to
cha
nge
the
spec
ifica
tion
with
out p
rior n
otic
e. 0
2/2
014
CR ultrafilterAbsolute filters for microparticles – EPA, HEPA, ULPA
Filtration class according to EN 1822:2010
H14 – U17Delivery options
frame widths: 70, 78, 90, 102, 110, 122 and 150 mmPossibility of regeneration
no
Filter propertiesCR ultrafilters are plate filters for microparticles. They protect persons, equipment and technologies against air-borne particle contaminants.
Filter mediumPapers from fine glass microfibres of various separation or penetration levels. The filter medium is folded into a pleat and the number and height of folds is optimally dimensioned for operating conditions.
Separatorsconsist of a melt adhesive, which provides high stability of the entire filter element.
Filter frameThe frame is made from an anodised aluminium section. If required, may be made of stainless steel.
Sealing of the filter pleat in the frameTwo-component polyurethane sealant.
SealsA special section from EPDM sponge rubber with closed surface. Form of the seal: flat, semi-circular, doubleedged. Gel seals, U-section seals and seals for high temperatures.
Protection against contact – protective grid:• on both sides• on one side, on the side of sealing• on one side, on the side without sealing• without protection against contact
Quality, defectoscopy, SCAN TEST**When ensuring the quality, our company puts stress on filter media, the production procedure and finished filter elements. Ultrafilters are made and tested according to a precisely set procedure. We distinguish among requirements of quality levels A to D.
Visual control, oil mist seepage test, test certificate according to EN 10204-2.3. Scantest with a test certificate for an extra charge.
Field of applicationIn areas with the highest demands for air cleanliness. The health sector - laminar ceilings, extensions for clean rooms, pharmaceutics, microbiology, production of CDs, food-processing industry.
Waste disposalIncineration in appropriate incinerators.
* SCAN TEST = computer controlled test of the filter medium with a laser particle counter.
67N ultrafiltersAbsolute filters for microparticles – EPA, HEPA, ULPA
Filtration class according to EN 779:2012, EN 1822:2010
F7 – U15Delivery options
610 (w) × 610 (h) × 292 (d) mm 305 (w) × 610 (h) × 292 (d) mm 762 (w) × 610 (h) × 292 (d) mmPossibility of regeneration
no
Filter propertiesN ultrafilters have a compact and robust design with a low risk of damage and an extra large filtration area. The use of the filter medium in the pleat enables extremely high intake-flow rates and flow rates up to 4,000 m3/h for a filter of dimensions 610 × 610 × 292 mm).
QualityUltrafilters of filtration class H13 and H14 always undergo the oil-thread leak test. ULPACATS computercontrolled test of the filter medium – for an extra charge.
Field of applicationClean rooms - pharmaceutical industry, health sector, nuclear power plants, microelectronics, industry.
MaterialFilter pleat from submicron glass fibre
Waste disposalFilters contaminated with outside air should be disposed of by incinerating or landfilling. Filters contaminated by toxic or radioactive particles should be disposed of as hazardous waste.
Technical dataUnit of
measureF7-V40 F9-V40 E11-V35 H13-P20 H13-V30 H13-V34-T H13-V40 H14-V35 U15-V30
Nominal air flow rate for
dimensions 610 × 610 mmm3/h 4,000 4,000 3,500 2,000 3,000 3,400 4,000 3,500 3,000
Nominal intake-flow rate m/s 3.0 3.0 2.6 1.5 2.25 2.55 3.0 2.6 2.25
Initial pressure loss at nominal load Pa 140 170 190 250 250 270 290 250 250
Recommended final pressure loss Pa 450 450 600 500 600 600 600 600 600
Maximum thermal resistance ˚C 125 125 125 70 125 220 125 125 125
v
Dimensions
hš
x
Type 610width: 609 mm (±1 mm)
Type 305width: 304 mm (±1 mm)
Type 762width: 762 mm (±1 mm)
Type 205width: 205 mm (±1 mm)
xNon-pressed seal, pressed about 5 mm
Depth hDepth of all the filters is 292 mm (±1 mm)
FILT
ER M
EDIA
PO
CK
ET
FILT
ERS
FRA
ME
FILT
ERS
CO
MPA
CT
FILT
ERS
AB
SO
LUTE
FIL
TER
S FO
R M
ICR
OP
AR
TIC
LES
CO
MP
ON
ENTS
FO
R
CLE
AN
RO
OM
SFI
LTER
UN
ITS
FOR
AIR
H
AN
DLI
NG
PIP
ELIN
ES
MO
UN
TIN
G F
RA
ME
SA
DSO
RP
TIO
N F
ILTE
RS
WIT
H A
CTI
VATE
D C
AR
BO
NA
CC
ES
SOR
IES
68
As
part
of o
ur p
rogr
amm
e of
con
tinuo
us im
prov
emen
t, K
S K
lima-
Serv
ice,
a.s
. re
serv
es th
e rig
ht to
cha
nge
the
spec
ifica
tion
with
out p
rior n
otic
e. 0
2/2
014
JP and JKAbsolute filters for microparticles – special design
Filtration class according to EN 779:2012, EN 1822:2010
F9 – H14Delivery options
from ø 155 to ø 300 mmPossibility of regeneration
no
Filter propertiesThe special circular filters JP and JK are made of submicron glass filter paper that is folded into a pleat and sealed in two-sided collars made of PU or stainless steel.
Filter frameMetal cover collars are made of aluminium or stainless steel. Collars of the JP filter are made of polyurethane.
SeparatorsSeparators are formed from thermoplastic melt adhesive.
JPCylindrical dust filter in filtration class F9 according to EN 779:2012. Filter medium from cellulose fibres. Collars from a flexible plastic material serving as a seal.
Mean efficiency level (atmospheric) EN 779:2012: 95 % Relative air humidity up to: 85 % Maximum thermal resistance: 90 °C Recommended final pressure loss: 500 Pa
JKCylindrical HEPA filter in filtration class H13 according to EN 1822:2012. Filter medium from submicron glass fibres. The clip for installation of the filter consists of a connecting brass ring and an ERP seal.
Mean efficiency level (atmospheric) EN 1822:2012: 99.99 %Relative air humidity up to: 100 % Maximum thermal resistance: 90 °C Recommended final pressure loss: 1,000 Pa
Height: 50–400 mm Diameter: 150 or 190 mm
SealsThe filter is equipped with a rubber collar or standardised screwed connection for connecting to the pipeline (e.g. for medicinal gases).
QualityH13 = oil-thread leak test. H14 = ULPACATS filter medium laser test certificate – for an extra charge
Field of applicationAll areas of air handling and distribution where it is necessary to filter a small quantity of air with a high efficiency of filtration, i.e. inlets and outlets of laboratories, chemical plants, medicinal gases cleaning, nuclear engineering, electrical engineering, etc.
MaterialFilter pleat from submicron glass fibre
Waste disposalLandfilling or incineration in authorised incineration plants.
69
JKG-W A plastic jacket of the JKG-W filter for use in air pipeline parts or similar applications.
Connection diameter: 125 mmAir flow direction: vertical/horizontal, downward/upwardEquipped with a condensate outlet, seals and brackets for installation on wall or ceiling.
Field of applicationAll areas of air handling and distribution where it is necessary to filter a small quantity of air with a high efficiency of filtration, i.e. inlets and outlets of laboratories, chemical plants, medicinal gases cleaning, nuclear engineering.
MaterialFilter media from glass microfibres JP and JK
JG and JKGAbsolute filters for microparticles – special design
Filter propertiesThe special circular filters JG and JKG are made of submicron glass filter paper that is folded into a pleat and sealed in two-sided collars made of PU or stainless steel. The filters are made also in a compact design including jacketing (JKG). The jacketing can be made of plastic or stainless steel. The filters enable loading of up to 14,000 Pa at flow rates of 80 to 150 m3/h.
Filter frameMetal cover collars are made of aluminium or stainless steel.
SeparatorsSeparators are formed from thermoplastic melt adhesive.
SealsThe filter is equipped with a rubber collar or standardised screwed connection for connecting to the pipeline (e.g. for medicinal gases).
QualityH13 = oil-thread leak test H14 = oil-thread leak test
JGCylindrical HEPA filter in filtration class H13 according to EN 1822:2012. Filter medium from submicron glass fibres. Metal parts from aluminium.
Variants:1. Without a protective cover2. With a protective cover3. With a stainless steel jacket
Mean efficiency level (atmospheric) EN 1822:2012: 99.99%Relative air humidity up to: 100 % Maximum thermal resistance: 90 °C Recommended final pressure loss: 1,000 Pa
Filtration class according to EN 1822:2012
H13 – H14Delivery options
from ø 155 to ø 300 mmPossibility of regeneration
no
FILT
ER M
EDIA
PO
CK
ET
FILT
ERS
FRA
ME
FILT
ERS
CO
MPA
CT
FILT
ERS
AB
SO
LUTE
FIL
TER
S FO
R M
ICR
OP
AR
TIC
LES
CO
MP
ON
ENTS
FO
R
CLE
AN
RO
OM
SFI
LTER
UN
ITS
FOR
AIR
H
AN
DLI
NG
PIP
ELIN
ES
MO
UN
TIN
G F
RA
ME
SA
DSO
RP
TIO
N F
ILTE
RS
WIT
H A
CTI
VATE
D C
AR
BO
NA
CC
ES
SOR
IES
Cylindrical filter inserts DIN
Filter inserts JET MULTIFIT
Filter inserts JET ABS
70 Filter insertsfor industrial filtration
Possibility of regeneration
no, 100 % recyclableMain fields of application
Powder painting, Plasma/laser cutting, Sanding Metal/Aluminium, Wood, Chemistry, Cement, Textile, Food-processing & beverages and other
Cylindrical filter inserts DIN• cylindrical and conical insert• open/closed & open/open• welded design• reinforced design due to a spiral structure• external fixing tapes for higher dynamics during the
cleaning/pulse process
Filter inserts JET ABS• 100 % ABS• with 3 or 4 eyes• replaceable on the both dirty and clean air side
Filter inserts JET• aluminium or zinc-coated covers• 100 % ABS• with 3 or 4 eyes• replaceable on the both dirty and clean air side
MULTIFIT pleated inserts – replacement of conventional filter bags• energy savings• higher air flow rate and efficiency• easier installation• 2–3 times bigger filtration area of the insert
Multifit compared to filter bags• longer service life• reduction of unavailability times
and maintenance costs
71COMPONENTS FOR CLEAN ROOMS
Components for clean rooms are filters and filtration equipment for areas with the highest demands on cleanliness. In this group, we offer CG inlet pressure ceilings with laminar flow, including designing, delivery and installation of the device.
KS extensions for clean rooms are an integral part of an air intake system. They are equipped with HEPA filters as standard and are used for air filtration and air distri-bution. Separation of microparticles, bacteria and viruses takes place immediately before entry into the clean room. The KS extensions for clean rooms are delivered in a standard size line or in a size required by the customer.
The equipment is suitable for the health sector - inlet ceilings, KS extensions for clean rooms, pharmaceutical industry, fine electrotechnics production, microbiology, manufacturing of CDs, food-processing industry, etc.
We offer validation of clean rooms and a validation certificate that includes:
• air flow rate through HEPA• HEPA faultlessness in central inlet• faultlessness of HEPA after-filters• cleanliness of supply air• cleanliness of the area and control points without operation• overpressure in a specified area, output and margin
72
As
part
of o
ur p
rogr
amm
e of
con
tinuo
us im
prov
emen
t, K
S K
lima-
Serv
ice,
a.s
. re
serv
es th
e rig
ht to
cha
nge
the
spec
ifica
tion
with
out p
rior n
otic
e. 0
2/2
014
CG inlet pressure ceilings with laminar flowComponents for clean rooms
• comfortable climate in the room, no draught• very low noise level• design with smooth surfaces resists to
disinfection agents• minimised concentration of germs
(< 10 germs / m³) in the sterile area• lower energy consumption due to minimised
pressure losses• perfect and tight integration of system items
Delivery options• designing and dimensioning according to the
customer’s requirements
FeaturesThe inlet pressure ceilings with laminar flow meet the highest health and technical demands, including the filtration (E12-U16) and distribution demands for the air inlet into clean rooms. They can be supplied with the basic ceiling lighting. If requested, it is possible to supply with air-tight shutting flaps enabling closing of the air supply if needed. A compact design with high adaptability to the existing building.
End outlets used:A double laminar flow diffuser from a special fine microfabric creates the laminar discharge flow under the whole ceiling.
Field of applicationClean rooms - operating rooms, pharmaceutical industry, microelectronics, fine optics.
CG inlet ceiling - operating room in department of gynaecology
CG inlet ceiling
The CG inlet ceiling minimises concentration of germs in the sterile zone
CG inlet ceiling
73KS extensions for clean roomsComponents for clean rooms
Delivery options
6 standard sizes, possibility to adapt to the customer’s requirementsAbsolute filters used
KS BESTFIL as standard, other options according to the customer’s requirements
FeaturesKS extensions for clean rooms are air outlets with integrated absolute filters for microparticles. The outlets are used for air filtration and distribution. Separation of microparticles, bacteria and viruses takes place immediately before the entry into the clean room. The extensions are supplied as ceiling and wall-mounted.
The KS extensions for clean rooms include a test groove enabling measurement of tightness of mounting of the filter and a connection for pressure measurement. The air is supplied through round connecting mouths into which it is possible to mount air-tight shutting flaps.
• Design of extensions for clean rooms enables air filtration and distribution of the filtered air
• Viruses, bacteria and dust particles are filtered from the air stream immediately before the outlet of air which eliminates risks connected with a central filtration system, such as cross contamination in ventilation pipelines
End outlets used:Perforated sheet metal, diffuser, whirl outlet.
The KS extensions for clean rooms are ideal for use everywhere where clean air or air free of germs is needed, e.g.:
• Hospitals: operating rooms and infirmaries, intensive care units, sterile zones and isolation wards
• I ndustry: ecologically clean production plants in the pharmaceutical, chemical, food-processing, optical and electronics industry
• L aboratories: clean rooms and work areas, clean air supply and filtration of toxic or harmful aerosols
QualityUltrafilters of filtration classes H13 and U15 always undergo the oil-thread leak test for faultlessness. A computer-controlled test of the filter media SCAN TEST and the test certificate according to EN 1822-4 are made to order.
Field of applicationClean rooms - pharmaceutical industry, health sector, laboratories, electrotechnics, microbiology, nuclear engineering.
FILT
ER M
EDIA
PO
CK
ET
FILT
ERS
FRA
ME
FILT
ERS
CO
MPA
CT
FILT
ERS
AB
SOLU
TE F
ILTE
RS
FOR
MIC
RO
PAR
TIC
LES
CO
MP
ON
EN
TS F
OR
C
LEA
N R
OO
MS
FILT
ER U
NIT
S FO
R A
IR
HA
ND
LIN
G P
IPEL
INE
SM
OU
NTI
NG
FR
AM
ES
AD
SOR
PTI
ON
FIL
TER
S W
ITH
AC
TIVA
TED
CA
RB
ON
AC
CE
SSO
RIE
S
74 FILTER UNITS FOR AIR-HANDLING PIPELINES
The design of the special filtration equipment for use in air-handling pipelines is adapted for an easy integration into the pipeline system. Its structure is solid and stable and manipulation is very easy. One KS BK may integrate even a multi-stage filtration from filtration class G1 to H13. The KS BK filtration equipment comes in dimensions range for air flow rates from 100 m3/h to 51,000 m3/h. The KS BK filtra-tion equipment can be combined with other equipments to achieve higher air flows. We offer complex services, from designing of the equipment to its installation.
The KS BK filter units are used when it is necessary to use pocket and compact filters, filter elements and compact filters with activated carbon at the same time. They may be used for air supply into telecommunication central offices, hospitals, pharmaceutical and electrical engineering plants, etc. In case of high cleanliness demands, we supply chambers in hygienic quality in filtration classes up to H13.
The NG filter units The NG channel filter units are stable units suitable in particular for areas with the need of supply of up to 12,000 m3/h of absolutely filtered air. Due to the possibility to assemble the units quickly and easily into variable sizes, they offer the possibility to use many types of KS filters.
A two-phase combination of filters consists of a KS FP filter for dust particles and a KS AFP adsorption filter for suppression of gases. They are mounted together into KS RS type mounting frames designed for this purpose. Both filter elements are placed one to another by flange sides and they are attached together into the KS RS mounting frame.
75KS BK filter unitsFilter units for air handling pipelines
Unit descriptionThe BK filter units are an ideal solution for filtration of coarse or fine dust in all pipelines of air-handling units. The KS BK filter chambers are made of frame aluminium profiles (framework), their jacketing is made of zinc-coated steel sheet metal. They can also be supplied in the design for the outdoor environment.
Possibility of filter installationIdeal for pocket filters KS PAK, compact filters KS FP, metal filter elements, activated carbon elements KS AFP, etc.
Field of applicationAir supply into telecommunication central offices, hospitals, pharmaceutical and electrical engineering plants, etc. In case of high cleanliness demands, we supply chambers in hygienic quality in filtration classes up to H13.
Manufactured range
KS BK 1 – BK 51Flow rate
1,000 – 51,000 m3/hStructural depth of chambers
500 – ca 2,000 mm
Advantages• easy integration into a pipeline system• solid and stable design• modern method of mounting of pocket and compact
filters in mounting frames• easy handling during installation• supplied with a pressure gauge for pressure loss
measurement• possibility to install compact filters, deliveries of
chambers with multi-stage filtration• design of chambers according to the customer’s
requirements, precisely according to specifications
Drawing description 1 mounting frame KS RA 2 pocket filter 3 clips for tight closing
of the door 4 removable door 5 base 6 strip flanges
(w = 30 mm) A width (outer chamber
dimension)
A1 width (connecting dimension of strip flanges)
B1 height (connecting dimension of strip flanges)
B2 base height (70, 100 mm)
SP flow direction
FILT
ER M
EDIA
PO
CK
ET
FILT
ERS
FRA
ME
FILT
ERS
CO
MPA
CT
FILT
ERS
AB
SOLU
TE F
ILTE
RS
FOR
MIC
RO
PAR
TIC
LES
CO
MP
ON
ENTS
FO
R
CLE
AN
RO
OM
S
FILT
ER
UN
ITS
FOR
AIR
H
AN
DLI
NG
PIP
ELI
NE
SM
OU
NTI
NG
FR
AM
ES
AD
SOR
PTI
ON
FIL
TER
S W
ITH
AC
TIVA
TED
CA
RB
ON
AC
CE
SSO
RIE
S
76
As
part
of o
ur p
rogr
amm
e of
con
tinuo
us im
prov
emen
t, K
S K
lima-
Serv
ice,
a.s
. re
serv
es th
e rig
ht to
cha
nge
the
spec
ifica
tion
with
out p
rior n
otic
e. 0
2/2
014
Special filter units with multi-stage filtrationSpecial applications
Special filter units with multi-stage filtration, including a fan and other air-handling componentsDesign
• mobile design • hygienic design • stainless, Komaxit design • design for explosive environments
Unit descriptionThe unit has a frame structure from aluminium profiles. Jacketing may be simple or double with insulation. The standard material is zinc-coated sheet metal, if required stainless steel or Komaxit treatment. The chambers may be equipped with multi-stage filtration - e.g. G4, F7 and activated carbon or G4, F9 and HEPA filters. The fan with continuous control of speed is supplied on request. The units are supplied also in a mobile design or treated for outside use.
Field of application • suction of dust particles and harmful substances in
electrical engineering• suction and cleaning of waste air from waste water
treatment plants• mobile suction in nuclear power plants• suction from laboratory, hospital and microbiological
workstations• pharmaceutical plants, airport terminals• suction of harmful substances from workstations in
plastics processing
77KS NICE AIRSpecial applications
FeaturesA brand new system of efficient filtration for separation of fine dust particles F7 and harmful gases and odours. The unit is made from aluminium profiles, panel jacketing is from zinc-coated sheet metal. Inspection door is equipped with handles for easy handling during filter replacement. A heart of the unit is a compact filter KS WA that is mounted in a mounting frame with a microporous seal.
Design• without fan• with fan and speed controller
Advantages• high adsorption capacity > 95 %• low pressure losses – energy costs savings, possibility
of retrofitting• filtration of fine dust particles and elimination of
odours in one phase• flow rate 100 m3/h to 1,000 m3/h• possibility to connection to the existing
air-handling system• unit’s filter designed in an all-plastic frame• the compact unit belongs among low-energy filters
Field of application Separation of fine dust particles, organic and aromatic hydrocarbons (e.g. xylene, toluene, benzine, acetates), exhaust gases, body, civilisational, cosmetic and cigarette odours and many other gaseous contaminants.
Fields of applicationFamily houses, electrical engineering, airports, hotels, restaurants, administrative buildings, etc.
Filtration class according to EN 779:2012
F7Design
• without fan • with fan and speed controllerDelivery options
dimensions according to customer’s requirements
KS NICE AIR variants
Without fan • dimensions: 365 × 365 × 500 mm
• with mounting frame for KS WA filter:
287 × 287 × 150 mm
• counterflanges; connecting dimensions:
305 × 305 mm
With fan • dimensions: 405 × 710 × 800 mm
• dimensions with mounting frame for KS WA filter:
287 × 592 × 150 mm
• continuous speed control,
air flow rate 0 to 600 m3/h
Possibility to deliver with or without the base.
Connecting dimensions: circular flange of diameter of 200 mm.
FILT
ER M
EDIA
PO
CK
ET
FILT
ERS
FRA
ME
FILT
ERS
CO
MPA
CT
FILT
ERS
AB
SOLU
TE F
ILTE
RS
FOR
MIC
RO
PAR
TIC
LES
CO
MP
ON
ENTS
FO
R
CLE
AN
RO
OM
S
FILT
ER
UN
ITS
FOR
AIR
H
AN
DLI
NG
PIP
ELI
NE
SM
OU
NTI
NG
FR
AM
ES
AD
SOR
PTI
ON
FIL
TER
S W
ITH
AC
TIVA
TED
CA
RB
ON
AC
CE
SSO
RIE
S
78
As
part
of o
ur p
rogr
amm
e of
con
tinuo
us im
prov
emen
t, K
S K
lima-
Serv
ice,
a.s
. re
serv
es th
e rig
ht to
cha
nge
the
spec
ifica
tion
with
out p
rior n
otic
e. 0
2/2
014
Special designNG units according to the requirements of customers combined in larger systems, assembled and sealed in the production plant. The NG units are supplied zinccoated or powder painted.
Field of applicationAreas with very high demands for cleanliness – health sector, laboratories, pharmaceutical production, CD production, fine optics, nuclear engineering, electrical engineering, automotive industry, hospital sterile zones.
Waste disposalLandfilling or incineration in authorised incineration plants.
NG filter unitsFilter units for air handling pipelines
Unit descriptionThe NG channel filter unit is made of zinc-coated or stainless sheet metal and is suitable for use in all pipeline systems for absolute filtration of inlet or waste air. The NG filter units are stable units suitable in particular for areas with the need of supply of up to 12,000 m3/h of absolutely filtered air. Due to the possibility to assemble the units quickly and easily into variable sizes, they offer the possibility to use many types of KS filters.
Possibility of filter installation• NG-K design: CR ultrafilters (E10-U15) + FP-P
prefilters for fine dust• NG-T design: type N ultrafilters and pre-filter for fine
dust - type KS-FP
Manufactured range
KS NG-K, KS NG-TFlow rate
do 4 000 m3/hStructural depth of chambers
550 – 750 mm
Type / size A B C V E D X Weight
NG-K-1/1 700 668 540 608 646 550 360 38 kg
NG-K-1/2 395 363 270 303 646/341 550 360 29 kg
NG-T-1/1 700 668 540 608 646 750 560 47 kg
NG-T-1/2 395 363 270 303 646/341 750 560 37 kg
NG-K
D = 550 mm
NG-K
D = 550 mm D = 750 mm
NG-T
Possibility of filter installation in NG unitsa/ CR ultrafilter + KS FP-P filter
for fine dustb/ N ultrafilter + KS FP-P filter
for fine dustc/ N ultrafilter + KS FP filter
for fine dust
a/ b/ c/
79Two-phase combination of M6-F9 filtersFilter units for pipelines – integrated structures
Filtration class according to EN 779:2012
M6, F9Delivery options
according to the KS RS 120 frame dimensions and parameters of airhandling and used filters
FeaturesA two-phase combination of filters consists of a KS FP filter for dust particles and a KS AFP adsorption filter for suppression of gases. They are mounted together into KS RS type mounting frames designed for this purpose. Both filter elements are placed one to another by flange sides and they are attached together into the KS RS mounting frame.
First filtration stage KS FP-M6 KS FP-F7 KS AFP-AZ
Filtration purpose particles částice gases (VOC)
Filtration class according to EN 779:2012 M6 F7 –
Efficiency according to EN 779:2012 60–80 % 80–90 % –
Separation capacity for toluene – – >− 95%
Second filtration stage KS FP-F9 KS AFP-AZ KS AFP-AS
Filtration purpose particles plyny (VOC s) acidic gases
Filtration class according to EN 779:2012 F9 – –
Efficiency according to EN 779:2012 98 % – –
Separation capacity for toluene – >− 95% –
Separation efficiency for SO2 and HCl – – >− 95%
Total data for the two-phase combination of filters (dimension 610)
Volume flow rate (m³/hod) (normal service life) 4,250 3,400 3,400
Initial pressure loss (Pa) 250 120 120
Nominal volume flow rate (m³/hod) – long service life 3,400 1,700 1,700
Initial pressure loss (Pa) 180 40 45
Weight (kg) – including the KS RS type frame 13.1 15.6 18.1
Field of applicationSeparation of very fine dust and airborne dust particles, harmful substances in air (so-called anthropogenic substances), smog, ozone, exhaust gases from internal combustion and diesel engines, kerosene, benzine and alcohol vapours, vapours from thinners. Elimination of putrid, body, civilisational and hospital odours and odours from food.
Waste disposalLandfilling or incineration in authorised incineration plants.
FILT
ER M
EDIA
PO
CK
ET
FILT
ERS
FRA
ME
FILT
ERS
CO
MPA
CT
FILT
ERS
AB
SOLU
TE F
ILTE
RS
FOR
MIC
RO
PAR
TIC
LES
CO
MP
ON
ENTS
FO
R
CLE
AN
RO
OM
S
FILT
ER
UN
ITS
FOR
AIR
H
AN
DLI
NG
PIP
ELI
NE
SM
OU
NTI
NG
FR
AM
ES
AD
SOR
PTI
ON
FIL
TER
S W
ITH
AC
TIVA
TED
CA
RB
ON
AC
CE
SSO
RIE
S
80 MOUNTING FRAMES
Mounting frames are designed for perfect mounting of pocket filters KS PAK, com-pact filter elements KS FP and other types of frame filters KS PL, KS Z, KS MA. Their construction is robust and very stable. Mounting of the filter into the frame is very simple with use of clamps. The clamps ensure automatic centring of the inserted filter and perfectly tight fastening of all types of filters.
Due to a simple modular structure, it is possible to make filter walls according to the customer’s requirements. Assembly of frames into air-conditioning units or suction openings is very simple. Supplies of non-standard frame sizes - according to require-ments also in stainless design.
Special frames KS RS 120 are used for mounting a pair of filters, e.g. combination of pre-filters and after-filters or filters with activated carbon KS FP, KS PAK, KA AFP, KS W, KS Z, KS PL. An excellent solution for manufacturers of air-conditioning units. New mounting of a pair of filters, small structural depth, easy mounting into air-conditioning units, suitable for filtration classes E10 - E12, H13 and suitable for combination into large filter walls.
81Mounting frames KS RAFiltration accessory equipment – mounting frames
FeaturesThe KS RA mounting frames are made of zinc-coated sheet metal, the frame includes 4 clamps and seals. The filters are mounted easily and safely by their inserting and pressing the clamps to the microporous seal. Side assembly openings facilitate assembly of frames into filter walls.
Use with filter types• KS-PAK pocket filters• KS-FP compact filters• KS-PL(25) frame filters• KS-W, KS-Z1 (25) frame filters• KS-AFP compact filters with activated carbon
Advantages• installation of frames into all air-conditioning units and
assembly into filter walls• perfectly tight fastening of filters by four clamps• automatic filter centring
An advantage of the KS RA frame is the variable mounting and subsequent dismounting of filters from both sides, i.e. in or against the direction of air flow.
Design
zinc-coated sheet metal, stainless steel if requiredDelivery options
610 (w) × 610 (h) × 70 (d) mm 508 (w) × 610 (h) × 70 (d) mm 305 (w) × 610 (h) × 70 (d) mm 305 (w) × 305 (h) × 70 (d) mm
FILT
ER M
EDIA
PO
CK
ET
FILT
ERS
FRA
ME
FILT
ERS
CO
MPA
CT
FILT
ERS
AB
SOLU
TE F
ILTE
RS
FOR
MIC
RO
PAR
TIC
LES
CO
MP
ON
ENTS
FO
R
CLE
AN
RO
OM
SFI
LTER
UN
ITS
FOR
AIR
H
AN
DLI
NG
PIP
ELIN
ES
MO
UN
TIN
G F
RA
ME
S
AD
SOR
PTI
ON
FIL
TER
S W
ITH
AC
TIVA
TED
CA
RB
ON
AC
CE
SSO
RIE
S
82
As
part
of o
ur p
rogr
amm
e of
con
tinuo
us im
prov
emen
t, K
S K
lima-
Serv
ice,
a.s
. re
serv
es th
e rig
ht to
cha
nge
the
spec
ifica
tion
with
out p
rior n
otic
e. 0
2/2
014
Mounting frames KS RS 120Filtration accessory equipment – mounting frames
Design
zinc-coated sheet metal, stainless steel if requiredDelivery options
610 (w) × 610 (h) × 120 (d) mm 508 (w) × 610 (h) × 120 (d) mm 305 (w) × 610 (h) × 120 (d) mm 305 (w) × 305 (h) × 120 (d) mm
FeaturesThe KS-RS mounting frames are made from stainless or zinc-coated sheet metal. They are equipped with 4 clamps that press the filter element to an integrated microporous seal.
Field of application pro typy filtrůThe frames are used for mounting a pair of filters, e.g. combination of pre-filters and after-filters or filters with activated carbon KS FP, KS PAK, KS AFP, KS W, KS Z, KS PL. An excellent solution for manufacturers of air-conditioning units. Combination of filters, e.g. FP+AFP, W+PAK, FP+FP, FP+PAK.
Advantages• new mounting of a pair of filters• small structural depth• easy mounting into air-conditioning units• suitable for filtration classes E10 – H13• suitable for combination into large filter walls
83ADSORPTION FILTERS WITH ACTIVATED CARBON
Activated carbon is used to adsorb odours and harmful gaseous impurities from air whose toxicity and smell are now a big burden for the environment and may be harmful for the humans, animals and plants. It has proven itself as an efficient agent. Activated carbon is used in air-conditioning, ventilating and special filtration equip-ment to clean the inlet, circulating and waste air. It is also a very efficient agent for treatment of drinking, industrial and waste water.
In most cases, activated carbon is added to filter cartridges that are manufactured in both standard and atypical designs. Filter cartridges are made from zinc-coated sheet metal, stainless steel or anodised.
Our range of filter units KS BD and KS BD BIG offers variable sizes depending on a concrete technical solution. A special equipment for sulfane elimination is a unique solution for water treatment plants. All the filtration devices with activated carbon are turnkey solutions delivered from design to assembly of the equipment.
Compact filters with various types of adsorption media containing non-impregnated or impregnated activated carbon are also used for elimination of odours and harmful gases. They are used in case of low concentrations (e.g. laboratories, specialised chemical establishments, etc.)
84
As
part
of o
ur p
rogr
amm
e of
con
tinuo
us im
prov
emen
t, K
S K
lima-
Serv
ice,
a.s
. re
serv
es th
e rig
ht to
cha
nge
the
spec
ifica
tion
with
out p
rior n
otic
e. 0
2/2
014
Examples of the adsorption, separation of harmful substancesOrganic substances, styrene, acetates, benzine, petroleum vapours, ammoniac, acidic and other gases, meat production odours, hospital odours, exhaust gases, formaldehyde and ammoniac odours.
Activated carbon usedNon-impregnated granulated high quality activated carbon, impregnated activated carbon if required.
RegenerationUsed activated carbon is poured out and thermally reactivated (regaining of efficiency). Saturated impregnated activated carbon cannot be reactivated.
KS KOPA and KS KOPA-BIGAdsorption filters with activated carbon
Adsorption filters with activated carbon
KS KOPA 450 KS KOPA 625 KS KOPA BIG filter cartridgesPossibility of regeneration
Yes
Filter propertiesThe KS KOPA filter system consists of a mounting frame and filter cartridges filled with activated carbon. The filter cartridge consists of two cylinders of different diameters made from a special perforated sheet metal. The intermediate space formed by the difference of diameters determines the width of the activated carbon layer. Activated carbon is optimally filled into this intermediate space on a shaking machine. The closed cartridge has a gasket that ensures a gas-tight mounting in the base frame. The cartridges are fixed to the base frame by three special clamping bolts through a bayonet closure and forms a stable filter unit. The KS KOPA-BIG type cartridges are used for high flow rates.
Field of applicationExhaust equipment in paint shops, removal of odours from kitchens and barbecue grills, adsorption of kerosene in airport terminal buildings, welding operations exhaust equipment, adsorption of harmful substances from soldering, industrial harmful substances from the chemical and electrotechnical industry, smog gases, nuclear power plants.
Technical data Unit of measure KS KOPA 450 KS KOPA 625 KS KOPA BIG
Flow rate m3/h up to 190 up to 190 1,800
Pressure loss Pa up to 130 up to 140 250
Cartridge diameter (outer) mm 145 145 367
Cartridge length mm 450 625 1,003
Activated carbon filling kg 2 2.8 23
Average cartridge weight including activated carbon kg 3.85 4.8 34
Adsorption capacity for C2H2 % max. 25 max. 25 max. 25
85KS BDCompact filter units with activated carbon
Dimensions ranges
KS BD 4 – 192 (700 – 36,000 m3/h)Possibility of regeneration
Non-impregnated activated carbon: Yes, thermal re-activation Pocket pre-filters F7: no
Filter propertiesThey represent an operational solution for separating of gaseous harmful substances from the natural or waste air. The units are made from aluminium frame profiles, the jacketing is made from zinc-coated sheet metal. As standard, they are equipped with two-stage filtration: 1st st. = pocket filters F7 for filtration of fine dust particles, 2nd st. = filter cartridges KS KOPA. The KS KOPA, KS BD filtration system is recommended and approved by the Czech Environmental Inspectorate Prague.
Field of applicationExhaust equipment in paint shops, removal of odours from kitchens and barbecue grills, adsorption of kerosene in airport terminal buildings, welding operations exhaust equipment, adsorption of harmful substances from soldering.
Examples of the adsorption, separation of harmful substancesMeat production odours, formaldehyde odour, organic substances, styrene, vapours of thinners and solvents, harmful substances from welding.
Activated carbon usedNon-impregnated granulated high quality activated carbon, impregnated activated carbon if required.
RegenerationPocket pre-filters F7 – no, activated carbon in filter cartridges - yes (thermal reactivation), impregnated activated carbon cannot be reactivated – replacement with new activated carbon.
Main areas of use of the KS BD filter units• Exhaust systems from paint shops and spraying
boxes, adsorption of odours from kitchens, meat production and barbecue grills, adsorption of harmful substances from chemical and electronics industry.
• Air inlets to airport terminals and railway station halls, exhaust systems from nuclear power plants.
• Air inlets and exhausts from operating rooms, intensive care units, control rooms, exhaust systems from water treatment plants, welding exhausts.
• Electronics production and other areas with presence of harmful gases or odours that need to be adsorbed - conference rooms, museums.
• Hospitals, laboratories, computer rooms, printing houses, petrol stations, car parks, garages.
2nd filtration stage – KS KOPA filter cartridges
1st filtration stage – KS PAK 85-F7 pocket filters
Connecting strip flanges (30 mm)
ApA
B Bp
C
100
(70)
FILT
ER M
EDIA
PO
CK
ET
FILT
ERS
FRA
ME
FILT
ERS
CO
MPA
CT
FILT
ERS
AB
SOLU
TE F
ILTE
RS
FOR
MIC
RO
PAR
TIC
LES
CO
MP
ON
ENTS
FO
R
CLE
AN
RO
OM
SFI
LTER
UN
ITS
FOR
AIR
H
AN
DLI
NG
PIP
ELIN
ES
MO
UN
TIN
G F
RA
ME
S
AD
SO
RP
TIO
N F
ILTE
RS
WIT
H A
CTI
VAT
ED
CA
RB
ON
AC
CE
SSO
RIE
S
86
As
part
of o
ur p
rogr
amm
e of
con
tinuo
us im
prov
emen
t, K
S K
lima-
Serv
ice,
a.s
. re
serv
es th
e rig
ht to
cha
nge
the
spec
ifica
tion
with
out p
rior n
otic
e. 0
2/2
014
KS BD BIGCompact filter units with activated carbon
Filter propertiesThe KS BD BIG compact units can be connected immediately to an air-handling pipeline. Due to their stable structure, it is recommended to install the KS BD BIG units on a concrete base.
Examples of the adsorption, separation of harmful substancesMeat production odours, formaldehyde odour, organic substances, styrene, vapours of thinners and solvents, harmful substances from welding.
Activated carbon usedSaturated impregnated activated carbon cannot be reactivated. It must be replace by new impregnated activate carbon.
Main areas of use of the KS BD BIG filter units:• Exhaust systems from paint shops and spraying
boxes, adsorption of odours from kitchens, meat production and barbecue grills, adsorption of harmful substances from chemical and electronics industry.
• Air inlets to airport terminals and railway station halls, exhaust systems from nuclear power plants.
• Air inlets and exhausts from operating rooms, intensive care units, control rooms, exhaust systems from water treatment plants, welding exhausts, electronics production and other areas with presence of harmful gases or odours that need to be adsorbed - conference rooms, museums.
• Hospitals, laboratories, computer rooms, printing houses, petrol stations, carparks, garages
Dimensions ranges
KS BD BIG 4 KS BD BIG 6 KS BD BIG 8 KS BD BIG 12 KS BD BIG 16Possibility of regeneration
Non-impregnated activated carbon: Yes, thermal reactivation
A new range of filter units for high concentrations of harmful substances and high flow rates from 7,000 m3/h up to do 50,000 m3/h.Main advantages of the new range of units are:
• Perfect pre-filtration of fine particles with help of compact filters KS FP, F7
• Dimensions range from 7,000 m3/h – possibility of unlimited assembly of any system for the required air flow rate
• Robust design, high filtration efficiency• Long servicing interval for the KS FP F7 pre-filter and
activated carbon in the KS KOPA BIG filter cartridges• Possibility to use impregnated activated carbon for
special types of harmful substances (smog gases, ammonia, landfill gases, gases from water treatment plants, etc.)
• We provide complete servicing during filters replacement and reactivation of used activated carbon
87SULOFF desulphurisation unitSpecial applications
SULOFF desulphurisation unit
Removal of sulfane (H2S) from biogas; technology developed in cooperation with the Institute of Chemical Technology in Prague
Unit descriptionCleaning takes place in an adsorption apparatus with a fixed bed through which biogas is flowing. The cylindrical stand of the adsorption apparatus is made of corrosion-proof steel with an opening in the upper part for filling with sorbent. For the purpose of gas inlet, the adsorption apparatus is equipped with the inlet pipeline with a standardised connecting flange. The adsorption apparatus is installed on a concrete bed with its supporting feet anchored to it. On its outer side, the adsorption apparatus is insulated with mineral and glass wool with a thickness of 100 mm – in the aluminium jacket covering the whole adsorption apparatus.
SorbentThe adsorption is performed using impregnated activated carbon in the form of small-sized granules. The weight of the filling depends on the type of the adsorption apparatus.
Field of applicationThe line of desulphurisation units serves for the removal of sulfane by means of adsorption using a special adsorption material – activated carbon with the subsequent catalytic oxidation to elemental sulphur that will be trapped by sorbent. The adsorption material deactivates in consequence of the release of elemental sulphur. Therefore, it is necessary to replace it after a certain period of time. The desulphurisation efficiency amounts to 96 – 99 %.
ServicingThe servicing provided by KS Klima-Service a.s. ensures the contactless change of the adsorption apparatus.
ReferencesWaste water treatment plants in Znojmo, Prostejov, Kromeríž, Kralupy nad Vltavou
Drawing description 1 AC container 2 gas inlet 3 gas outlet 4 condensate discharge 5 filling opening for AC
replacement
6 electric heating of condensate discharge
7 safety valve 8 pressure gauge 9 thermometer 10 gas blow off 11 platform with
staircase
FILT
ER M
EDIA
PO
CK
ET
FILT
ERS
FRA
ME
FILT
ERS
CO
MPA
CT
FILT
ERS
AB
SOLU
TE F
ILTE
RS
FOR
MIC
RO
PAR
TIC
LES
CO
MP
ON
ENTS
FO
R
CLE
AN
RO
OM
SFI
LTER
UN
ITS
FOR
AIR
H
AN
DLI
NG
PIP
ELIN
ES
MO
UN
TIN
G F
RA
ME
S
AD
SO
RP
TIO
N F
ILTE
RS
WIT
H A
CTI
VAT
ED
CA
RB
ON
AC
CE
SSO
RIE
S
88
As
part
of o
ur p
rogr
amm
e of
con
tinuo
us im
prov
emen
t, K
S K
lima-
Serv
ice,
a.s
. re
serv
es th
e rig
ht to
cha
nge
the
spec
ifica
tion
with
out p
rior n
otic
e. 0
2/2
014
Waste disposalFilters contaminated with the outdoor air should be disposed of by incineration or landfilling. Filters contaminated with toxic or radioactive gases should be disposed of as hazardous waste.
KS AFP-AZseparation of hydrocarbons
KS AFP-AZ-DUOseparation of hydrocarbons including pre-filtration F7
KS AFP-AAseparation of polymers
KS AFO-ASseparation of acidic and corrosive gases
AFP – adsorption filters with activated carbonAdsorption filters with activated carbon
Delivery options
592 (w) × 592 (h) × 300 (d) mm 592 (w) × 287 (h) × 300 (d) mm 592 (w) × 490 (h) × 300 (d) mm 592 (w) × 402 (h) × 300 (d) mm
Filter propertiesThe KS AFP compact filters provide an excellent solution for removing molecular pollution and improvement of the quality of the inlet and circulating air in the air conditioned buildings. The filter frame is made of recycled non-flammable halogen-free polystyrene, the filter medium is sealed in the frame with polyurethane.
Field of applicationMicroelectrotechnical industry, airports, hotels, restaurants, administrative buildings, museums, hospitals, laboratories, pharmaceutical industry, smog gases.
Examples of the adsorption, separation of harmful substancesExhaust gases, thinner and solvent vapours, body odours, cosmetic odours, hospital odours, kitchen odours, food odours, etc.
Filter medium usedA special filter medium made of synthetic fibres with very small particles of adsorbent. The AFP-AA, AFP-AS types contain impregnated adsorbent, the AFP AZ type contains non-impregnated adsorbent.
25 mm 592 mm (w)
300 mm (d)
h
Type 305height: 287 mm
Type 420height: 402 mm
Type 508height: 490 mm
Type 610height: 592 mm
89KS WA – panel filterPanel filter for elimination of gaseous harmful substances and odours
Dimensions ranges
according to the customer’s requirements (h × w maximally up to 610 mm)Possibility of regeneration
No
Filter propertiesThe KS WA panel filter is an efficient solution for separation of gaseous harmful substances and odours. Its use enables to achieve a substantial improvement of air quality. The KS WA panel filter is a new generation of filters, so-called dual-phase, for adsorption of fine dust and the entire spectrum of gaseous harmful substances and harmful organic substances
Filter descriptionThe KS WA filter is made from a special filter medium that consists of multiple layers and contains up to 400 g/m2 of activated carbon. The medium is pleated in order to get a maximum filter area and consequently mounted and sealed into a robust plastic frame. It is a brand new filter suitable and efficient for adsorption of organic hydrocarbons (VOCs), DOP, BHT, silicone, MEK, EL, PGME, THFA, exhaust gases of combustion and diesel engines, asphalt vapours, tar vapours, kerosene vapours, benzine vapours, vapours from solvents, e.g. from paints and varnishes, vapours from glues, rubber and cleaning agents, air pollutants (socalled anthropogenic agents), smog, ozone, body, civilisational, cosmetic and cigarette odours, hospital, alcohol and antiseptic odours, odours from kitchens and foodstuffs, putrid odours and many other gaseous harmful substances. This filter has a very low initial pressure loss. The pressure loss is 10 Pa at flow rate of 100 m3/h and 30 Pa at flow rate of 500 m3/h. That is why the filter belongs among low-energy filters.
Fields of applicationAs a main and efficient filter in KS NICE AIR units. It is also used mainly in air-handling systems, airport terminals, hotels, restaurants, administrative buildings, museums, libraries, hospitals, households, etc. An efficient solution for filtration of harmful aerosols during smog threats.
Waste disposalThe filter is fully incinerable
Advantages of KS WA• high adsorption efficiency > 95 %• low pressure losses – energy costs savings, possibility
of retrofitting into air-handling equipment• filtration of fine dust particles F7 and separation of
harmful substances and odours in one phase• no flue dust• no back desorption• solid plastic frame (ABS)• for installation into standard frames and skids like
pocket filters• low weight – easy handling
FILT
ER M
EDIA
PO
CK
ET
FILT
ERS
FRA
ME
FILT
ERS
CO
MPA
CT
FILT
ERS
AB
SOLU
TE F
ILTE
RS
FOR
MIC
RO
PAR
TIC
LES
CO
MP
ON
ENTS
FO
R
CLE
AN
RO
OM
SFI
LTER
UN
ITS
FOR
AIR
H
AN
DLI
NG
PIP
ELIN
ES
MO
UN
TIN
G F
RA
ME
S
AD
SO
RP
TIO
N F
ILTE
RS
WIT
H A
CTI
VAT
ED
CA
RB
ON
AC
CE
SSO
RIE
S
90
As
part
of o
ur p
rogr
amm
e of
con
tinuo
us im
prov
emen
t, K
S K
lima-
Serv
ice,
a.s
. re
serv
es th
e rig
ht to
cha
nge
the
spec
ifica
tion
with
out p
rior n
otic
e. 0
2/2
014
PL-CARB – adsorption filters with activated carbonAdsorption filters with activated carbon
Delivery options
529 (w) × 592 (h) × 25 (d) mm 287 (w) × 592 (h) × 25 (d) mm and other non-standard dimensions according to the customer’s requirementsPossibility of regeneration
partial regeneration
Filter propertiesA special adsorption filter medium CARBOTEX – a nonvowen polyester fabric with content of activated carbon - is mounted into a metal frame. A single-side covering grid from expanded metal
Field of applicationFor adsorption of odours from kitchens and barbecue grills. Suitable for adsorption of some organic hydrocarbons.
Waste disposalLandfilling or incineration in authorised incineration plants
91Non-impregnated activated carbonAdsorption filters with activated carbon
Packaging
Bags of 25 kg Big Bag of 500 kgPossibility of regeneration
Yes – thermal reactivation
Filter propertiesActivated carbon in form of cylindrical granules of diameter 3 – 4 mm and length 4 – 8 mm. High resistance to abrasion, ideal for adsorption of organic hydrocarbons and odours
Basic technical data about the granulated carbon of type SC 40Appearance: extruded carbon, granules, diameter about 4 mm Density after shaking: 450 ± 25 kg/m3 Iodine number: min. 1,050 mg/g Water content during packaging: 6 % max. Adsorption of CCI4: 70 % min.
Field of applicationAdsorption of odours, harmful gases.
Field of applicationFor use in the KS KOPA, KS BD, KS KOPA BIG, KS BD BIG systems and in filter cartridges.
Group no. 1very good adsorption 20 – 50 % of AC weightToluene, xylene, benzine, phenols, benzene, chloroform, perchloroethylene, styrene, acetates, kerosene, turpentine, odours from kitchens, smokehouses and meat production, harmful substances from welding, odours from waste water treatment plants, body odours, harmful substances from gluing and soldering, solvents, tobacco smoke, hospital odours, disinfectants, benzole
Group no. 2good adsorption 10 – 18 % of AC weightEther, anaesthetics, acetone, methyl alcohol, phosgene, acetates, smog gases.
Group no. 3very low adsorption capacity 3 – 8 % of AC weightAcrolein, ethane, propane, ethylene, chlorine, methane, ammonia, formaldehyde, carbon dioxide.
Note: It is necessary to use impregnated activated carbon.
FILT
ER M
EDIA
PO
CK
ET
FILT
ERS
FRA
ME
FILT
ERS
CO
MPA
CT
FILT
ERS
AB
SOLU
TE F
ILTE
RS
FOR
MIC
RO
PAR
TIC
LES
CO
MP
ON
ENTS
FO
R
CLE
AN
RO
OM
SFI
LTER
UN
ITS
FOR
AIR
H
AN
DLI
NG
PIP
ELIN
ES
MO
UN
TIN
G F
RA
ME
S
AD
SO
RP
TIO
N F
ILTE
RS
WIT
H A
CTI
VAT
ED
CA
RB
ON
AC
CE
SSO
RIE
S
92
As
part
of o
ur p
rogr
amm
e of
con
tinuo
us im
prov
emen
t, K
S K
lima-
Serv
ice,
a.s
. re
serv
es th
e rig
ht to
cha
nge
the
spec
ifica
tion
with
out p
rior n
otic
e. 0
2/2
014
Impregnated activated carbonAdsorption filters with activated carbon
Packaging
Bags or barrels of 25 – 30 kgPossibility of regeneration
No
Filter propertiesImpregnated granular activated carbon is used for the adsorption of gases and vapours that are adsorbed by standard activated carbon very little or are not adsorbed at all. These are low-molecular and polar substances with a low concentration and toxic effects. The complex chemical reaction of a harmful substance with an impregnating agent brings about the removal of the substance from the air – harmful gases are chemically bonded to the impregnating agent in activated carbon (chemical adsorption). When it is required to separate various harmful substances in one unit at the same time, it is necessary to design a multi-stage filtration unit with activated carbon impregnated at various levels.
Field of applicationFor use in the KS KOPA, KS-BD, KS KOPA BIG, KS BD BIG systems.
Waste disposalEnvironmentally friendly disposal according to applicable standards and laws.
93ACCESSORY EQUIPMENT
Pressure gauges are used for detection of pressure losses in built-in air filters. They may be used to measure underpressure or overpressure (e.g. in spraying boxes). Due to an easy mounting and low price, they are indispensable for detecting the final pressure loss of the filter. It increases substantially the efficiency of use of a filter and brings operating costs savings.
Pressure gauges can be mounted easily on filter chambers and they are supplied with accessories (contrast liquid, delivery hoses...) or with the possibility of electronic connection to automatic control (a higher measurement and regulation system). We supply pressure gauges in ranges from 50 to 50,000 Pa. We supply also a Magne-helic line of pressure gauges in the range from 1,000 – 5,000 Pa.
94
As
part
of o
ur p
rogr
amm
e of
con
tinuo
us im
prov
emen
t, K
S K
lima-
Serv
ice,
a.s
. re
serv
es th
e rig
ht to
cha
nge
the
spec
ifica
tion
with
out p
rior n
otic
e. 0
2/2
014
Pressure gauges for pressure loss measurementAccessory equipment
7030 with an inclined tubePressure gauge descriptionThe inclined tube (made of acrylic) with the possible setting of 2 ranges, i.e. 0 – 250 Pa and 0 – 500 Pa, is located in a plastic case. The vessel with contrast liquid is located in the back part of the case. The pressure gauge is supplied with accessories.
Measurement rangeOptional (tube inclination setting): 0 – 250 Pa and 0 – 500 Pa.
7030-EK with inclined tube and electronic control (optional)Pressure gauge descriptionThe inclined tube (made of acrylic) with the possible setting of 2 ranges, i.e. 0 – 250 Pa and 0 – 500 Pa, is located in a plastic case. The vessel with contrast liquid is located in the back part of the case. The pressure gauge is supplied with adjustable electrical contacts for the connection to the measurement and control system.
Measurement rangeOptional (tube inclination setting): 0 – 250 Pa and 0 – 500 Pa
Accessory equipmentContrast liquid (blue), bushes, hoses and fastening screws.
95
1,000Pressure gauge descriptionThe acrylic U-tube is located in a steel case. The pressure gauge range is 0 – 1,000 Pa. The pressure gauge is supplied without accessories.
Measurement rangeOptional (tube inclination setting): 0 – 1,000 Pa
2,500Pressure gauge descriptionThe acrylic U-tube is located on a plastic scale. The pressure gauge is supplied with accessories.
Measurement rangeOptional (tube inclination setting): 0 – 2,500 Pa
Accessory equipmentContrast liquid (blue), bushes, hoses and fastening screws.
Pressure gauges for pressure loss measurementAccessory equipment
5 000 – MagnehelicPressure gauge descriptionThe scale with a range of 0 – 5,000 Pa is located in a metal case. The pressure gauge is supplied with accessories.
Measurement range0 – 5,000 Pa
Accessory equipmentBushes, hoses, and erection bolts.
We supply the complete line of Magnehelic pressure gauges.
FILT
ER M
EDIA
PO
CK
ET
FILT
ERS
FRA
ME
FILT
ERS
CO
MPA
CT
FILT
ERS
AB
SOLU
TE F
ILTE
RS
FOR
MIC
RO
PAR
TIC
LES
CO
MP
ON
ENTS
FO
R
CLE
AN
RO
OM
SFI
LTER
UN
ITS
FOR
AIR
H
AN
DLI
NG
PIP
ELIN
ES
MO
UN
TIN
G F
RA
ME
SA
DSO
RP
TIO
N F
ILTE
RS
WIT
H A
CTI
VATE
D C
AR
BO
N
AC
CE
SS
OR
IES
96
As
part
of o
ur p
rogr
amm
e of
con
tinuo
us im
prov
emen
t, K
S K
lima-
Serv
ice,
a.s
. re
serv
es th
e rig
ht to
cha
nge
the
spec
ifica
tion
with
out p
rior n
otic
e. 0
2/2
014
Environmental profile
Our air filters are designed and manufactured with a main objective, which is to provide clean air in the most efficient way, for a competitive price and with a mini-mum impact on the environment. Part of our corporate philosophy is to offer to our customers complete care, i.e. also for used filters. We perform ecological disposal of used filters by landfilling or incinerating in appropriate waste incinerators.
Our company own a licence and authorisation to collect used filters from all regions of the Czech Republic. We are a holder of a trade licence in the field of hazardous waste management and, therefore, we may offer to our custom-ers all the necessary administrative support in each con-crete case of collection of used filters.
In January 2006, the company got an environmental management system certificate according to the CSN EN ISO 14001:2005 standard, which guarantees to our cus-tomers the highest quality of care about the environment. These services are turnkey services that include collection of used filters from the building (our vehicles have the ADR authorisation to transport hazardous waste), recording of amount of waste and making out of relevant transport and waste disposal documents required by law.
We provide disposal of used filters under the catalogue number 15 02 03 and 04 02 22 (under the amendment to Act no. 185/2001 on waste) and disposal of hazardous waste under the catalogue number 15 02 02 N (filter ma-terials), etc.
Environmental policy of KS Klima – Service, a. s.The joint-stock company KS Klima-Service, a.s. is a manufacturer and supplier of air filters for air-condition-ing and ventilation in filtration classes G2 - U17. Pro-tection and creation of the environment, creation of safe and healthy work conditions for its employees and their continuous improvement, including prevention of pollu-tion, belong permanently to the highest priorities of the company.
In order to meet these goals, the management of KS Klima-Service,a.s. has adopted the following principles:• Based on regular assessment of the environment
pollution, suitable measures to permanently reduce the load on the environment are determined.
• During all activities performed by the company, measures are taken to limit the creation of wastes and reduce the energy consumption.
• Rigorous prevention is used in order to prevent accidents and situations, which could have negative effect on the environment and health of employees.
• During all activities related to the realization of products provided by the company, all valid legal regulations related to the environment shall be observed.
• Legal regulations related to the protection of the environment will be elaborated into the internal documentation, assigning the responsibility of individual employees and monitoring that the regulations are being observed.
• When selecting suppliers of materials, goods or services, the qualification of supplier with regards to the environmental protection shall be taken into account.
• All employees are periodically trained and educated on the requirements regarding the environmental protection.
• The top management commits to observe all legal and other requirements relevant for KS Klima-Service, a.s.
• The top management commits to always improve all processes and activities.
97Production, research and development
Production – maximum flexibility according to the requirements of customersBy means of a responsible approach to each order, provi-sion of additional services at a high level (transport, eco-friendly waste disposal, etc.), and introduction of up-to-date production technologies (media folding equipment, media cutting equipment, production of HEPA filters by means of the minipleat technique, etc.), KS Klima-Ser-vice a.s. intends to provide its customers with maximum comfort and to maintain a high quality standard.
The KS Klima-Service research centre offers several filter testing optionsOur testing facilities offer verification of pressure loss val-ues at a given flow rate or tests of faultlessness and effi-ciency of HEPA filters. One of the test devices is a test rig for measuring parameters of air filters. The rig has been constructed with a view to accelerating the development of new products and ensuring precise technical basic data for our products. The whole rig, its dimensions, lengths, and basic data for the location of measuring elements have been determined in compliance with ISO 5801 and EN 779 standards.
Another device is a mobile station for EPA, HEPA filters de-fectoscopy for testing of filters of higher filtration classes E10 – E12, H13 – U17 – by means of the oil thread leak test ac-cording to EN 1822-4, Annex A. Those filters are used in the environments with high demands for air cleanliness, e.g. in operating rooms. The test facilitates the detection of even smallest damages to the filters. Filters designed for areas with the highest cleanliness demands are tested on our new-est and state-of-the-art automatic scanning device TOPAS AFS 150. Measurement results are recorded in a certificate on verification of filter faultlessness and efficiency.
Research and developmentIn the course of previous years, the experts of KS Klima-Service a.s. developed several important filters and filter devices launched successfully on the domestic and foreign markets. They include especially a filter system for separat-ing microparticles and gaseous particles in nuclear power stations, SULOFF adsorption equipment for removing sul-fane from biogas, KS MPP M6-F9 frame filters or small compact filter units KS NICE AIR designed in particular for elimination of harmful gases and odours in passive houses.
In the following period, we will concentrate on the de-velopment of new highly efficient filters with low initial pressure losses and on the application of new synthetic materials in the production of modern pocket filters.
Scan test for HEPA and ULPA filters
Rig for measuring parameters of air filtersDefectoscopy mobile station
98
V rá
mci
naš
eho
prog
ram
u ne
ustá
lého
zle
pšov
ání s
i KS
Klim
a-Se
rvic
e, a
.s.
vyhr
azuj
e pr
ávo
na z
měn
u sp
ecifi
kace
bez
pře
dcho
zího
upo
zorn
ění.
02
/201
4
We guarantee a 100% quality of our products
Cutting plotter for production of frame filters New premises for production and reactivation of filters with AC
Automatic line for manufacturing of filter pleats using the MINIPLEAT system