Appendix to ISO/lEG 17025 accreditation certificatenumber: L 240
of Thales Nederland B.V.Environmental Competence CentreHengelo
Valid from: 01-07-2008 till 26-05-2011 Replaces appendix dated: 26-05-2007
Nr. Material or Product Type of activity Internal referencenumber
EMC Test
n ................................................................
Ir. J.C. van der Poel
i ~.~.i.~.~..~~~.~~.~i~.~ i
nex has been approved by:
Page 1 of 3
1 Electronic and/or electric Conducted Emission measurement on Power 9501 120 276xx
apparatus Leads, 30 Hz-10 kHz conformMIL-STD4610,CE101
2 Conducted Emission measurement on Power 9501 120 277xxLeads, 10 kHz-10 MHz conformMIL-STD461D,CE102
3 Conducted Immunity measurement on Power 9501 120 250xx
Leads, 30 Hz- 50 kHz conformMIL-STD4610, CS101
4 Conducted Susceptibility measurement on all 9501 120 257xx
Leads, 10 kHz- 30 MHz conformMIL-STD461D,CS114
5 Conducted Susceptibility measurement on all 9501 120 258xx
Leads, damped sine - 10 kHz- 100 MHz conformMIL-STD461D,CS116
6 Radiated Emission measurement 9501 120 376xxH-field 30 Hz-100 kHz conformMIL-STD461D,RE101
7 Radiated Emission measurement, 9501 120 442xxE-field 10 kHz-18 GHz conformMIL-STD4610, RE102
8 Radiated Susceptibility measurement, 9501 120 272xx
H-field, 30 Hz-100 kHz conformMIL-STD461D,RS101
9 Radiated Susceptibility measurement, 9501 120 274xxE-field, 14 kHz-18 GHz conformMIL-STD461D,RS103
10 Conducted Emission measurement on Power 9501 027 905xx
Leads, 30 Hz- 10kHz conformMIL-STD461E,CE101
11 Conducted Emission measurement on Power 9501 027 906xxLeads, 10 kHz- 10 MHz conformMIL-STD461E,CE102
12 Conducted Susceptibility measurement on Power 9501 027 91Oxx
Leads, 30 Hz- 150 kHz conformMIL-STD461E,CS101
Appendix to ISO/lEG 17025 accreditation certificatenumber: L 240
of Thales Nederland B.V.Environmental Competence CentreHengelo
Valid from: 01-07-2008 till 26-05-2011 Replaces appendix dated: 26-05-2007
Page 2 of 3
Nr. Material or Product Type of activity Internal referencenumber
13 Electronic and/or electric Conducted Susceptibility measurement on all 9501 027 911 xx
apparatus Leads, BCI - 10 kHz- 200 MHz conformMIL-STD461E,CS114
14 Conducted Susceptibility measurement on all 9501 027912xx
Leads, impulse excitation conformMIL-STD461E,CS115
15 Conducted Susceptibility measurement on all 9501 027 913xx
Leads, damped sine - 10 kHz- 100 MHz conformMIL-STD461E,CS116
16 Radiated emission measurement, H-field 9501 027 907xx30 Hz- 100 kHz conformMIL-STD461E,RE101
17 Radiated Emission measurement, E-field 9501 027 908xx10 kHz- 18 GHz conformMIL-STD461E,RE102
18 Radiated Immunity measurement, H-field 9501 027914xx30 Hz- 100 kHz conformMIL-STD461E,RS101
19 Radiated Immunity measurement, E-field 9501 027 915xx2 MHz - 18 GHz conformMIL-STD461E,RS103
20 ESD Immunity test 9501 120 445xxconformEN6100-4-2
21 Radiated Immunity measurement, 9501 120 446xxE-field 80 MHz-2 GHz conformEN61000-4-3
22 Conducted Immunity measurement on Power and 9501 120 447xxInterconnection Leads, Transients/Burst conformEN6100-4-4
23 Conducted Immunity measurement on Power and 9501 120 448xx
Interconnection Leads, Surges conformEN61000-4-5
24 Conducted Immunity measurement on Power and 9501 120 449xx
Interconnection Leads, CW, 150 kHz-80 MHz conformEN6100-4-6
25 Radiated Immunity measurement at Power 9501 120 840xx
frequency conform EN 61000-4-8
26 Conducted Emission measurement at Mains 9501 120 455xxPower Connection, Harmonic Currents conformEN61000-3-2
27 Conducted Emission measurement at Mains 9501 120 456xx
Power Connection, Voltage Fluctuation and Flicker conformEN61000-3-3
28 Conducted Immunity measurement on Power 9501 120 450xx
Leads, Voltage variations and-interruptions conform EN 61000-4-11
Appendix to ISO/lEG 17025 accreditation certificatenumber: L 240
of Thales Nederland B.V.Environmental Competence CentreHengelo
Valid from: 01-07-2008 till 26-05-2011 Replaces appendix dated: 26-05-2007
Shock and Vibration Test
Page 3 of 3
Nr. Material or Product Type of activity Internal referencenumber
29 Electronic and/or electric Conducted Emission measurement on Power 9501 120451 xxapparatus Leads, 150 kHz-30 MHz conformEN55011
30 Radiated Emission measurement, 9501 120 452xxE-field 30 MHz-1 GHz conform EN 55011
31 Conducted Emission measurement on Power 9501 120 453xx
Leads, 150 kHz-30 MHz conformEN55022
32 Radiated Emission measurement, 9501 120 454xx
E-field 30 MHz-1 GHz, Class B conformEN55022,classB
33 Electronic and/or method 514.4Vibration procedure I 9505 002 783xx
electric apparatus as method 516.4Shock procedure I and II conformMIL-STD-810Ewell as mechanical
34 apparatus method 514.5 Vibration procedure I 9505 002 783xx
method 516.5 Shock procedure I and II conformMIL-STD-810F
35 method 2040 Sine Vibrations test condition A-B-C 9505 002 783xx
method 2131:3Shock (specified pulse) conformMIL-STD-202Fmethod 214A Random Vibration test condition A-B-C
36 method 2040 Sine Vibrations test condition A-B-C 9505 002 783xx
method 213B Shock specified pulse conformMIL-STD-202Gmethod 214A Random Vibration test condition A-B-C
37 Publication 2-6 Sine Vibration testing 9505 002 783xx
Publication 2-27 Shock testing conformIEC68- IEC60068
Publication 2-29 Bump testing (DNV- 2002,GL-2003,Publication 2-34 Random Vibration testing LRTypeapprovalsystem2002Publication 2-64 Random Vibration testing ETSIEN300019-2-4)
38 Shock testing: 9505 002 783xx
Publication 3-1, Publication 3-2, Publication 3-3, conform IEC 721
Publication 3-4, Publication 3-5. (ETSIEN300019-2-4)
39 Vibration testing 9505 002 783xxconformIEC945-IEC 60945
40 Mechanical Vibrations of Shipboard Equipment 9505 002 783xxconform MIL-STD-167-1