APPROVAL SHEETAPPROVAL SHEET
DESCRIPTION : 16 X CCD COLOR CAMERA
SET MODEL NO. : ONZ - AN101 /151/102/152 ( NTSC) ONZ - AP101 /151/102/152 ( PAL )
ISSUED
CHECKED
APPROVED
DATE : 11. Jul. ‘00REVISION No. 1.0MESSRS.
Receipt Stamp
ONIX SYSTEM INC.
4 FLOOR, KUNAM B/D, 5- 4, YANGJAE- DONG, SEOCHO- KU, SEOUL, 137- 130, KOREA
TEL: 82- 2- 596- 0144/ 82- 2- 573- 0144TEL: 82- 19- 310- 2213FAX : 82- 2- 596- 0143URL:http://www.globalsources.com/onix.coURL:http://www.onix.co.kr E- mail:[email protected]
ONZ-AN101/151/102/152, AP101/151/102/152 Specifications
ONIX SYSTEM INC.
CCD COLOR CAMERA SPECIFICATIONS
ONZ - AN101, 151, AP101, 151 : Control through RS-232 Signal ( TTL Level )
ONZ - AN102, 152 AP102, 152 : Control through RS-422/485 Signal
CONTENTS
1/11
1. SPECIFICATIONS------------------------------------------------------------ 2
2. MEASUREMENT SPECIFICATIONS------------------------------------ 4
3. EXTERNAL CONTROL SPECIFICATIONS---------------------------- 4
4. ENVIRONMENT CONDITION AND TEST----------------------------- 5
5. LAYOUT OF PLUG --------------------------------------------------------- 5
6. INTERFACE (RS-232C)---------------------------------------------------- 6 7. INTERFACE(RS-422/485) ------------------------------------------------- 7 8. RECOMMENDED CIRCUIT FOR LOCAL CONTROLS ----------- 8
9. LENS TEST CONDITION-------------------------------------------------- 9
9. APPEARANCE--------------------------------------------------------------- 10
10.PACKING METHOD-------------------------------------------------------- 11
PAGE
ONZ-AN101/151/102/152, AP101/151/102/152 Specifications
ONIX SYSTEM INC.
1. SPECIFICATIONS
Signal System NTSC ( ONZ - AN101/102 ) PAL ( ONZ - AP101/102 )
Scanning System 2 : 1 Interlace
Scanning Frequency ( H ) 15.734 KHz 15.625 KHz
59.94 Hz 50 Hz
Image Sensor 1 / 4 Inch Solid State Interline CCD Image Sensor
Total Pixels No.
Effective Pixels No.
Scanning Frequency ( V )
REMARKS
811 (H) X 508 (V) 410K 795 (H) X 596 (V) 470K
768 (H) X 494 (V) 380K 752 (H) X 582 (V) 440K
Signal System NTSC ( ONZ - AN151/152 ) PAL ( ONZ - AP151/152 )
Scanning System 2 : 1 Interlace
Scanning Frequency ( H ) 15.734 KHz 15.625 KHz
59.94 Hz 50 Hz
Image Sensor 1 / 4 Inch Solid State Interline CCD Image Sensor
Total Pixels No.
Effective Pixels No.
Scanning Frequency ( V )
REMARKS
537 (H) X 505 (V) 270K 537 (H) X 597 (V) 320K
510 (H) X 492 (V) 250K 500 (H) X 582 (V) 290K
1) Lens F1.4 ~ 2.8 , f = 4.0 ~ 64.0 mm , x16 Zoom Video Auto Focus
Angle of View H : 47 。 (WIDE) , 3 。 (TELE)
High Durability Zoom Lens
a) Zoom Durability More than 500k at Room Temperature ( See Page. 6. )
b) Focus Durability More than 500k at Room Temperature ( See Page. 6. )
c) Iris Durability More than 500k at Room Temperature ( See Page. 6. )
2) Focus Length ∞ ~ 1.0m (Tele) ~ 0.01m (Wide)
3) Signal Process Digital Signal Process
4) Sync System(Auto) Internal / External sync ( Line Lock)
5) Camera Function Control through RS-232 Signal ( TTL Level ) : CNB-AN101,151,AP101,151 Control through RS-422/485 Signal : CNB-AN102,152,AP102,152
a) Optical Zoom TELE ~ WIDE (Zoom Speed : 3.6 sec / 6 sec )
b) Digital Zoom Off / On ( ~ 8 times )
c) Video Focus Auto / Manual ( NEAR ~ FAR ) / Push Auto
(a) Manual Mode
Zoom Start Zoom Stop
Manual Manual ( AF Action is activated for a moment before focus stops )
“ Bold : Default Mode ”
2/11
ONZ-AN101/151/102/152, AP101/151/102/152 Specifications
ONIX SYSTEM INC.
d) White Balance Auto / Indoor / Outdoor / Push Auto / Manual ( R&B Gain Level UP/Down ) Special ( R or B Gain Level Control )
e) Shutter Speed Auto/ Manual (1/60 ~ 1/ 10000 ( NTSC) / 1/50 ~ 1/10000 (PAL) )
f) Iris Control Auto / Manual ( Manual Iris Level : UP ~ Down) g) Gain Control Auto / Manual ( Auto Gain Control : UP ~ Down)
h) Sharpness Manual ( Sharpness UP ~ Down )
i) Brightness Manual ( Brightness UD ~ Down )
j) Negative Off / On ( Negative Level UP ~ DOWN )
k) OSD Function On / Off (See an Annexed Document “ APPENDIX 1 ” )
l) Flickerless Off / On ( 1 / 100 sec Shutter Set (NTSC) / 1 / 120 sec Shutter Set (PAL) )
m) Back Light Off / On/ Auto
n) Position Preset 64 Mode Set / Move ( Store with Internal EEPROM )
(a) Zoom Trace Preset Mode : MF Trace
* In case of memory ( EX. Memory Point : )
WIDE TELE×1 ×16 ×32(Opt.) (Digi.)
3.6 sec 1 sec
(b) Zoom Trace Preset Mode : MF NO-Trace
* In case of preset
WIDE TELE×1 ×16 ×32(Opt.) (Digi.)
1.6 sec Instant
6) Video Output Level
NTSC
Video Level
Sync Level
0.714 ± 0.07V ( 100 ± 10 IRE)
0.286 ± 0.035V ( 40 ± 10 IRE)
Burst Level 0.286 ± 0.035V ( 40 ± 10 IRE)
700 ± 70 mV
300 ± 35 mV
300 ± 35 mV
PAL
Video Level
Sync Level
Burst Level
3/11
ONZ-AN101/151/102/152, AP101/151/102/152 Specifications
ONIX SYSTEM INC.
7) Color Reproduction
NTSCAmplitude ( % )
Phase ( 。 )
100 %(Base)
180 。 (Base)
RED BLUE YELLOW BURSTCOLOR
200 ± 40 %
103 ± 20 。
PALAmplitude ( % )
Phase ( 。 )
100 %(Base)
135 。 (Base)
130 ± 40 %
345 ± 20 。 115 ± 40 %
170 ± 20 。 200 ± 40 %
103 ± 20 。 130 ± 40 %
345 ± 20 。 115 ± 40 %
170 ± 20 。
8) Horizontal Resolution More than 480 Lines ( High Resolution ) More than 380 Lines ( Normal Resolution )
9) Luminance S/N More than 48 dB
10) Sensitivity Typ. 1Lux ---- At signal Level 30 IRE
( LENS-F : F = 1.4 ( WIDE ) AGC Gain : Max
11) Supplied Voltage 9.0 V ~ 15.0 V ( Recommendation 12.0 V ± 0.5 V )
12) Supplied Current 210 mA ( Steady-state )
350 mA ( Max ) ----- Under the zooming and focusing Operation
13) Power consumption 4.3 W (Max)
14) Dimensions 58.0(W) × 59.8 (H) × 101.2(D) mm ( Except Connector )
15) Weight 330 g ( Approx. )
16) Appearance / Dimensions See Attached Page 10.
17) Body Color Black
18) Packing Method See Attached Page 11.
19) Optional Accessories
2. MEASUREMENT SPECIFICATIONS
* Standard Measurement Condition and Measurement Procedure
See an Annexed Document “ APPENDIX 2 ”
3. EXTERNAL CONTROL SPECIFICATIONS
* External Control Using RS-232C ( Command List )
See an Annexed Document “ APPENDIX 3 ”
4/11
ONZ-AN101/151/102/152, AP101/151/102/152 Specifications
ONIX SYSTEM INC.
1) Operating Condition Temperature -10 。 C ~ 50 。 C ( Recommendation : -5 。 C ~ 40 。 C )
Humidity 10 % 85 %∼
2) Storage Condition Temperature -20 。 C ~ 60 。 C Humidity 0 % 90 %∼
3) High Temperature storage Test
Leaving the packed at Temperature of 60 。 C for 72 Hours, and then after leaving it at
Normal Temperature for 8 Hours, there should be no Problem in Performance.
4) Low Temperature storage Test
Leaving the packed at Temperature of -20 。 C for 72 Hours, and then after leaving it at
Normal Temperature for 8 Hours, there should be no Problem in Performance.
4. ENVIRONMENT CONDITION AND TEST
5/11
5. LAYOUT OF PLUG ( REAR PANNEL)
-+DC 12V
TELE(+)
(-)WIDE
BLC(SET)
MENU
VIDEO OUT
CONTROL
POWER INClass 2 Only
ONZ-AN101/151/102/152, AP101/151/102/152 Specifications
ONIX SYSTEM INC.
6. INTERFACE ( RS -232C TTL : ONZ-AN101,151,AP101,151 )
1-1) Pin Assignment ( 6 Pin Circle Connector )
Key
NAMEPIN No.
1
2
3
4
5
6
I/O
Input
Note
Input
1) Pin Diagram ( 6 Pin Circle Connector ) : Rear View
W
1
2 5
3
6
4
GND
Output
Input Green
White
Brown
Yellow
Black
Red
* is the color of the cable. ( If it offered )
GND
* Color
RD(For RS-232C)
TD(For RS- 232C) CMOS Level 5V ( Low : Max 0.8V , High : Min 3.7V )
CMOS Level 5V ( Low : Max 0.8V , High : Min 3.7V )
Line IN EX. FV ( Negative. 5 Vp-p )
1
2
3
4
5
6
7
8
9
1. Frame GND2. RD3. TD4. DTR5. Signal GND6. DSR7. RTS8. CTS9. RI
A) RS-232C D-Sub Connector
2) PC Interface
RD 1
TD 2
6/11
NAME
ONZ-AN101/151/102/152, AP101/151/102/152 Specifications
ONIX SYSTEM INC.
7. INTERFACE (RS - 422/485 : ONZ-AN102,152,AP102,152 )
1-1) Pin Assignment ( 6 Pin Circle Connector )
T+
NAMEPIN No.
1
2
3
4
5
6
I/O
Input
Note
1) Pin Diagram ( 6 Pin Circle Connector ) : Rear View
W
1
2 5
3
6
4
GND
Output
Input Green
White
Brown
Yellow
Black
Red
* is the color of the cable. ( If it offered )
T -
* Color
R+
R -
)
Line IN EX. FV ( Negative. 5 Vp-p )
2) PC Interface ( RS-422 Communication)
Input
Output
R + 1
R - 2
T + 3
T - 4
Tx+
Tx-
Rx-
Rx+
TD
RD
A) RS-232C TO RS-422 Converter
1. Frame GND2. RD3. TD4. DTR5. Signal GND6. DSR7. RTS8. CTS9. RI
1
2
3
4
5
6
7
8
9
B) RS-232C D-Sub Connector
7/11
NAME
ONZ-AN101/151/102/152, AP101/151/102/152 Specifications
ONIX SYSTEM INC.
2) Line In Pulse ( EX. FV)
Min : 200 nsec
60 Hz ± 0.25 Hz ( NTSC )
50 Hz ± 0.25 Hz ( PAL)
5 V
0 V
A) Pulse- Signal Spec of EX.FV
1) KEY Function(CNB-AN101/151/AP101/151)
8. RECOMMENDED CIRCUIT FOR LOCAL CONTROLS
8/11
POWERON/OFF
6.8K 8.2K 12K 18K 33K 68K 180K
TELE(+)
0.01uFKEY 3
MENU WIDE(-) A/MPUSH AUTO
NEGAON/OFF
NEAR(+) FAR(-)
: WIRE REMOTE CONTROL KEY FUNCTION
ONZ-AN101/151/102/152, AP101/151/102/152 Specifications
ONIX SYSTEM INC.9/11
9. LENS TEST CONDITION
1) Zoom
2) Focus
1.5sec
1 Cycle
3 ) Auto Iris
1.5sec
3 sec
TELE
WIDE 1 sec pause
1 Cycle
NEAR
FAR1V pause
1V pause
1V
1 Cycle
OPEN
CLOSE
RESET
ONZ-AN101/151/102/152, AP101/151/102/152 Specifications
ONIX SYSTEM INC.
10. APPEARANCE
10/11
46
1 4.
VID
MO
O
=
E
FO
UAO
TO
SUCf 4.0
~04. 6
m
:1
m
CITP
61LAX RWPO E
OZ
SER
. N
o.
MO
DEL
NO
.M
AD
E IN
KO
REA
ONZ-AN101/151/102/152, AP101/151/102/152 Specifications
ONIX SYSTEM INC.
11. PACKING METHOD
11/11
DESC.
10
9
7
8
NO
6
QT'Y
TAPE
BOX INNER ASSEMBLY
BOX, MASTER CARTON
PAD
LABEL SHIPPING
0.005
1.0
1/12
1/12
2/12
PACKING, MAIN
BOX, INNER
SET
LABEL, SERIAL No.
DESC.
5
4
2
3
NO
1
1.0
2.0
1.0
QT'Y1.0
MANUAL 1.0
2
3
4
3
5
1
BOX INNER ASSEMBLY
APPENDIX 1
ONZ - AN101 /151/102/152 ( NTSC) ONZ - AN101 /151/102/152 ( PAL)
DATE : 11. Jul. ‘00REVISION No. 1.0
MODEL :
OSD(On Screen Display)
ONIX SYSTEM INC.
ONZ-AN101/151/102/152, AP101/151/102/152 Specifications
ONIX SYSTEM INC.
1. OSD(On Screen Display ) FORMAT
<Fig. 1 OSD DISPLAY POSITION>2) DESCRIPTION
1
OSD Format DESCRIPTION REMARKS
2
FUNCTION
Focus ModeNon display Focus Auto Mode
Focus Manual Mode
Mirror ModeMirror Mode Off
1) OSD DISPLAY POSITION
Non display
X10000 ID 255
WAIT
W T X32
1 2 3 4 5 6
7
8
Mirror Mode On
3
Back LightBack Light OFF
Back Light ON
Non display
4
Non display White Balance AUTO
WBC MODE
Push Auto White Balance:In this mode “Push Key” pressed,the white point traced automatically(PWB Auto Mode),“Push key” released, the white point preserved currently (PWB Manual Mode).
A Auto Back Light ON
1/5
ONZ-AN101/151/102/152, AP101/151/102/152 Specifications
ONIX SYSTEM INC.
* The OSDs of 1,2,3,4,5,7,8 disappear 5 sec later . But 6 can be displayed continuously by ID On/Off Key Action ( controlled by PC command Key).
OSD Format DESCRIPTION REMARKSFUNCTION
5 Shutter Speed
Normal Shutter ( NTSC:1 / 60 PAL:1 / 50 )
1 / 125 . . . .
1 / 1 0 0 0 0
28 variable steps.(Can be set to 8 steps by manufactureOption)
Non display
6 CAMERA IDAfter input the Identification Number to each camera ,Multi-point control is available (PC Control )( 000 255 ) . ∼
7 WAIT MODE WAITIndicates the camera stand-by modeuntil the camera power turns ON .
8
ZOOM DISPLAY
W
W
T X10
T X20
; In case of 16X Zoom; Optical Zoom only mode ; (Current Zoom :10X)
; In case of 32X Zoom ; Digital Zoom 2X mode ; (Current Zoom : 20X)
W T X100
; In case of 128X Zoom ;Digital Zoom 8X mode ; (Current Zoom : 100X )
Sharpness Adjustment Mode DISPLAY
BrightnessAdjustmentModeDISPLAY
X10
X34
2/5
ONZ-AN101/151/102/152, AP101/151/102/152 Specifications
ONIX SYSTEM INC.
2. MENU DESCRIPTIONS ( ENGLISH )
1) MENU FORMAT
<Fig2. MENU FORMAT>
MENU 1 IMAGE MIRROR OFF (ON) 2 NEG / POS POS (NEG) 3 COLOR ON (OFF) 4 WB CONTROL AUTO (PUSH AUTO) 5 SHUTTER 1/10000 6 CAMERA ID 123
MENU
7 ZOOM START X1 8 ZOOM STOP X128 9 BRIGHTNESS 2410 SHARPNESS 1011 FOCUS AUTO (PUSH AUTO)12 INIT SET OFF (ON) END
TELE BLC
WIDE MENU
(+)
(-)
(SET)
<Fig3. REAR PANNEL>
3/5
ONZ-AN101/151/102/152, AP101/151/102/152 Specifications
ONIX SYSTEM INC.
3 ) MENU DESCRIPTION
(1) IMAGE MIRROR When IMAGE MIRROR is ON state , The image displays in the opposite direction.
(3) COLOR ON : Color Mode , OFF : B / W (Monochrome Mode).
(2) NEG/POS Use to change NEGATIVE and POSITIVE mode . ON : Negative Mode , OFF : Positive Mode .
(7) ZOOM START Wide Zooming Area Start point allocation (1 ~128).
(4) WB CONTROL Use to change White Balance Mode. - AUTO : WB Range 2800 。 K 8000 ∼ 。 K . - PUSH AUTO : In this Mode you can adjust White point by using PUSH AUTO Key. (5) SHUTTER Use to change the Shutter Speed . At this time , AE mode acts automatically ( 28/8 steps control is available ).
(6) CAMERA ID Each Identification number can be assigned to each camera. And ID NOs can be displayed on Monitor to confirm each camera. ( 000 ~ 255 : total numbers of ID are 256 ) .
(8) ZOOM STOP Tele Zooming Area End point allocation (1 ~128).
(9) BRIGHTNESS Use to change the brightness level of scene ( 0 ~ 48 ). (10) SHARPNESS Use to change the contour of scene ( 0 ~ 15 ) .
(11) FOCUS Use to change Focus Mode . - AUTO : Focusing acts Automatically - MANUAL : Focusing is controlled by Far and Near Keys . - PUSH AUTO : Auto Focusing is activated for a moment (when Push Auto Key is pressed) and stops.
(12) INIT SET Turn the initial mode ON , the changed data are renewed to manufacturer settings. (The data are initialized to its shipping condition )
2) Using MENU (1) Menu Mode : In order to display the MENU on the screen , Press the MENU key . If you keep pressing MENU over 2 seconds, OSD will be off.
Menu mode will be displayed again once Menu is pressed.
(2) Menu Item selection Mode: Position Hand Mark to each ITEM you want to change by using Wide and Tele Keys . Press the BLC(SET) button. (3) Menu Data Change Mode: Press the TELE and WIDE key .Then the right side of selected ITEM will blink and the values can be changed by using Tele and Wide keys . Press the BLC(SET) button. (4) Press the BLC(SET) key again to return to Mode(2). (5) To escape from Menu Mode, Press Menu key again in Mode(2). Remarks : BLC(SET) Key Switches Menu Item selection Mode(2) and Menu Data change Mode(3).
4/5
APPENDIX 2
ONZ - AN101 /151/102/152 ( NTSC) ONZ - VP101 /151/102/152 ( PAL)
DATE : 11. Jul. ‘00REVISION No. 1.0
MODEL :
Measurement SpecificationsMeasurement Specifications
ONIX SYSTEM INC.
ONZ-AN101/151/102/152, AP101/151/102/152 Specifications
ONIX SYSTEM INC.
1. MEASUREMENT CONDITIONS1) Standard Measurement Conditions Supplied Voltage DC 12V ± 0.5 V Ambient Temperature 23 ℃ Humidity 60 % RH Measurement Fixture Video output , DC input , RS-232C level Convert ( 5Vpp -> 12Vpp) Power Supply 12V ± 0.5 V Color Monitor CMM20 - 11 , Shibasoku or Equivalent Monochrome Monitor More than 800 TV Lines Horizontal Resolution Waveform Monitor / Vector Scope 1720A , Tektronix ( NTSC / EIA ) or Equivalent 1730A , Tektronix ( PAL / CCIR ) or Equivalent S / N ( Signal to Noise )Meter VN31AX , Shibasoku ( NTSC/PAL/EIA/CCIR ) or Equivalent Illumination Meter / Color Temperature Meter XY-1 / CL-100 , Minolta Camera or Equivalent Light Box Dai Nippon Printing Co. - Color Temperature 3200 。 K ± 100 。 K - Illumination More than 2000 Lux Test Charts ( Transparent Chart ) Color Bar Chart , Dai Nippon Printing Co. Gray Scale Chart , Dai Nippon Printing Co. ( Gamma 0.45 ) Resolution Chart , Dai Nippon Printing Co. ( Reflective Chart ) Gray Scale Chart , Murakami Color Research Lab Light Source Halogen Lamp ( with Dimmer Switch ) - Color Temperature 3200 。 K ± 100 。 K - Illumination Variable with Dimmer Color Temperature Filter LB 140 , Hoya or Kenko or Equivalent ( Color Temperature Conversion Filter ) Adjustment PC With Serial Port 1 or 2 RS-232C Cable Each Terminal Connector ( D-Sub 9 Pin )
2. Measuring System1) System 1.
MeasurementFixture
Light Box
ColorMonitor
MonochromeMonitor
Waveform /Vector scope
FFC
PC withSerial Port2) System 2.
Light Source
Same as above System 1.
Camera
Camera
Reflective Chart
EQUIPMENTS
1/5
ONZ-AN101/151/102/152, AP101/151/102/152 Specifications
ONIX SYSTEM INC.
2. MEASUREMENT PROCEDURE
1. VIDEO OUPUT LEVEL
TEST CONDITIONS
MEASURING SYSTEM
Refer to “ 1. MEASUREMENT CONDITIONS “
System 1.
PROCEDURE :
1. Shoot the gray scale chart , and Zoom WIDE or TELE to fit a scene of monitor fully by PC .2. Measure the video output level on the waveform monitor ( Before the above measurement , Measure the SYNC and BURST level )
A
B
C
( Fig 1. ) Video Output Waveform
SPECIFICATION :
NTSC
Video Level A
Sync Level B
100 ± 10 IRE
40 ± 5 IRE
Burst Level C 40 ± 5 IRE
700 ± 70 mV
300 ± 35 mV
300 ± 35 mV
PAL
Video Level A
Sync Level B
Burst Level C
2/5
ONZ-AN101/151/102/152, AP101/151/102/152 Specifications
ONIX SYSTEM INC.
2. COLOR REPRODUCTION
TEST CONDITIONS
MEASURING SYSTEM
Refer to “ 1. MEASUREMENT CONDITIONS “
System 1.
PROCEDURE :
1. Shoot the color bar chart , and Zoom WIDE or TELE to fit a scene of monitor fully by PC . 2. Measure the color amplitude and color phase on the vector scope of Red,Blue,Yellow . ( Before the above measurement , Adjust the burst amplitude and phase on the vectorscope so that the burst level becomes 100% and its phase becomes 180 。 (NTSC) (135 。 PAL)
( Fig 2. ) Video Output Waveform
SPECIFICATION :
NTSCAmplitude ( % )
Phase ( 。 )
( Fig 3. ) Video Output Color Vector
100 %
180 。
RED BLUE YELLOW BURSTCOLOR
200 ± 40 %
103 ± 20 。
PALAmplitude ( % )
Phase ( 。 )
100 %
135 。
130 ± 40 %
345 ± 20 。 115 ± 40 %
170 ± 20 。 200 ± 40 %
103 ± 20 。 130 ± 40 %
345 ± 20 。 115 ± 40 %
170 ± 20 。
3/5
ONZ-AN101/151/102/152, AP101/151/102/152 Specifications
ONIX SYSTEM INC.
3. LUMINANCE S / N
TEST CONDITIONS
MEASURING SYSTEM
Refer to “ 1. MEASUREMENT CONDITIONS “
System 1.
PROCEDURE :
1. Shoot the light box , and zoom WIDE or TELE to fit a scene of monitor fully by PC . 2. The noise meter settings are ; Input level : Preset High Pass Filter : 100KHz Low Pass Filter : 4.2 MHz Sub-carrier Trap : On Weighting : On Sag & Hue Comp. : Optimum 3. Measure the maximum S/N on the noise meter .
SPECIFICATION :
NTSC : More than 48 dBPAL : More than 48 dB
4. HORIZONTAL RESOLUTION
TEST CONDITIONS
MEASURING SYSTEM
Refer to “ 1. MEASUREMENT CONDITIONS “
System 1.
PROCEDURE :
1. Shoot the resolution chart , and Zoom WIDE or TELE to fit a scene of monitor fully by PC . 2. Adjust the brightness and contrast of the B/W monitor so that each steps of gray scale part can be observed . 3. Change the scan size of monitor to underscan. 4. The reference arrows on the resolution chart are positioned at the edge of the underscanned picture . 5. Change the scan size of monitor from underscan to overscan . 6. Measure the maximum horizontal resolution on the picture .
SPECIFICATION :
More than 480 TV Lines ( High Resolution)More than 380 TV Lines ( Normal Resolution)
4/5
ONZ-AN101/151/102/152, AP101/151/102/152 Specifications
ONIX SYSTEM INC.
5. LOW LUMINANCE SENSITIVITY
TEST CONDITIONS
MEASURING SYSTEM
Refer to “ 1. MEASUREMENT CONDITIONS “
System 2.
PROCEDUTE :
1. Shoot the gray scale chart ( reflective ), and zoom WIDE fully by PC . 2. Adjust the brightness of the light source using the dimmer switch so that the white peak level of the chart becomes 30 IRE ( NTSC ) ( 210 mV ,PAL ) on the waveform monitor . 3. Measure the level of illumination using the illumination meter .
SPECIFICATION :
5/5
NTSC (HI) : 1 Lux ( 30 IRE )PAL (HI) : 1 Lux ( 210 mV )
NTSC (Normal) : 0.5 Lux ( 30 IRE )PAL (Normal) : 0.5 Lux ( 210 mV )
APPENDIX 2DATE : 14 . JULY. ‘00REVISION No. 1.1
RS - 232C Communication ProtocolRS - 232C Communication Protocol
ONIX SYSTEM INC.
ONZ - VN100 /150 ( NTSC )ONZ - VN101 /151 ( NTSC )ONZ - VN102 /152 ( NTSC )ONZ - VP100 /150 ( PAL )ONZ - VP101 /151 ( PAL )ONZ - VP102 /152 ( PAL )
MODEL :
ONZ-AN101/151/102/152, AP101/151/102/152 Specifications
ONIX SYSTEM INC.
1. Communication Format
2) The communication data format from PC to Camera
1 command consists of 11 codes and
The data of total 11 bytes are transmitted from PC to camera. TOTAL 11 ASCII CODES.
(b) Description ; 1’ST CODE : START CODE
2’ND CODE : THE HIGH CHARACTER OF CAMERA ID
3’RD CODE : THE LOW CHARACTER OF CAMERAI ID
4’TH CODE : COMMAND High
5’TH CODE : COMMAND Low
6’TH CODE : DATA 4
7’TH CODE : DATA 3
8’TH CODE : DATA 2
9’TH CODE : DATA 1
10’TH CODE : Check Sum High
11’TH CODE : Check Sum Low
(a) Format ;
3) The communication data format from Camera to PC (Echo back data format )
; The data of total 11 bytes are transmitted from Camera to PC. * TOTAL 11 ASCII
1) Connection Conditions ; Data Length 1 Byte = 1code ( 8 Bit )
Stop Bit 1 Bit
Parity Bit None
Baud rate 9,600 bps
First last
* IDH IDL CH CL D4 D3 D2 D1 C.SH C.SL
(b) Description ; 1’ST CODE : START CODE
2’ND CODE : DATA 8 ( ID Code does not affect communication now)
3’RD CODE : DATA 7 ( ID Code does not affect communication now)
4’TH CODE : DATA 6
5’TH CODE : DATA 5
6’TH CODE : DATA 4
7’TH CODE : DATA 3
8’TH CODE : DATA 2
9’TH CODE : DATA 1
10’TH CODE : Check Sum High
11’TH CODE : Check Sum Low
(a) Format ;
First last
* IDH IDL CH CL D4 D3 D2 D1 C.SH C.SL
* Check Sum Method: ADD data1 to data 9 without carry.* If it becomes 3A as result of checksum data, It needs to be changed to ASC code [ ‘3’ ‘A’] Ⅱ
Communication between the microcomputer of the camera and the PC is available
by using the RS - 232C. The microcomputer receives each control command given by the PC
through RXD INPUT TERMINAL and it echoes back to the PC through TXD OUTPUT TERMINAL
1/10
ONZ-AN101/151/102/152, AP101/151/102/152 Specifications
ONIX SYSTEM INC.
4) Communication Flow
2/10
start
Send command (11codes)
Are echo back data transmittedfrom camera ?
Delay 20 ms
Command transmission is ok !
Send next command
Camera returns echo back data after execution of command from PC,So , in case of “Internal Zoom TrackingPRESET Moving control command “Echo back data can be delayed to several seconds . The minimum delay time between command and echo back data is 1 Milli-second.
NO
END
YES
4) Miscellaneous for Communication
* When transmitting 11 code of command, keep 2 Milli-seconds of waiting time between codes.
* If command transmission is stopped after 3 code only , camera waits for the remain 8 codes continuously. At that moment, If new command ,starting from ‘*’ (Start code ) is transmitted to camera, the previous 3 codes are ignored !
* IF echo back codes are error , there can be some troubles in communication line or data receiving timing . On software, you can send command again !
* About echo back : After 1 command , you need to wait for echo back data from camera for Transmission confirmation and next command transmission . But 1 more command transmission is possible before echo back data 20 milli second after first transmission.
ONZ-AN101/151/102/152, AP101/151/102/152 Specifications
ONIX SYSTEM INC.
2. RS - 232C Communication Commands : ‘X’ indicates don’t care code and “YY” indicates checksum
1) Camera RESET Reset the micro controller ( u-COM ) of Camera.
2) Camera ID Display ON/OFF control
Switch the display of camera ID (ON/OFF).
3) CAM ID READ . ZZ : Camera ID
4) CAM ID CHANGE ; Change the data of CAM_ID to “ NEW_C_ID “ .
5) Key Action ; See Page 10
Key action can be activated by this command. *XX75ZZXXYY
ZZ : Key CODE
Caution ; When you want to stop key action, send this command again
by using “KC_STOP “
. KEY CODE : Refer to 10-3.( Key Code Table ) for desired
key action selection.
*XX71XXXXYY
*XX7201XXYY
*XX7200XXYY
; ID ON
; ID OFF
*XX73XXXXYY
*XX74ZZXXYY
ZZ : NEW ID CODE
6) Camera Power ON/Off Turn on the power of Camera. *XX760ZXXYY Z(1) : Power On Z(0) : Power Off
3/10
*XXZZXXXXYY :Return data
7) Function OSD Display Mode RD *XX79XXXXYY
Read the Function OSD Display Mode of the camera
*0ZXXXXXXYY ;return data
Return Data :
Z(0) : “ Function OSD ON” mode. : All osd display is enabled
Z(1) : “ Function OSD OFF” mode : Excluding Menu osd display ,All osd display is disabled.
8) Function OSD Display Mode Change *XX7A0ZXXYY
Change the Function OSD Display Mode of the camera
Z(0) : The Function OSD Display Mode is changed to
“ Function OSD ON” mode.
Z(1) : The Function OSD Display Mode is changed to
“ Function OSD OFF” mode.
ONZ-AN101/151/102/152, AP101/151/102/152 Specifications
ONIX SYSTEM INC.
10) Camera Read Command of Digital Effect status *XX7EXXXXYY
Read the current Digital Effect status of the Camera.
The return data is “DEFT_Status”.
Construction of DEFT_Status data *0ZXXXXXXYY ;RETURN DATA
Z(0) : NO DIGITAL EFFECT IS ACTIVATED
Z(1) : WIDE(Cinema effect) ON
Z(2) : ART ON
Z(3) : Mirror ON ,
Z(4) : Nega effect on.
Z(5) : COLOR OFF.
Z(6) : MOSAIC ON .
11) Read the Exposure Mode *XX80XXXXYY
Read the current Exposure Mode of the Camera.
The return data is “AE MODE”. *0ZXXXXXXYY ;return data
Z(0) : AUTO Exposure mode
Z(1) : SHUTTER Manual mode.
Z(2) : IRIS Manual mode.
Z(3) : AGC Manual mode
Z(4) : SHUTTER / IRIS / AGC All Manual mode
12) Exposure Mode Set Command *XX810ZXXYY Set the mode of Exposure according to “AE Mode”
Z(0) : AUTO Exposure mode Z(1) : SHUTTER Manual mode. Z(2) : IRIS Manual mode. Z(3) : AGC Manual mode Z(4) : SHUTTER / IRIS / AGC All Manual mode
4/10
9) CAMERA status Read Command *XX7C0ZXXYY
Read the current status of the Camera.
*0RXXXXXXYY(RETURN DATA)
Z(0) : Focus Mode READ --> R (0) : Focus Auto R(1) :Focus Manual
Z(1) : Camera ID Display ON mode, --> R (0) : Camera ID Display OFF R(1) :DISPLAY ON
Z(3) : BACKLIGHT ON state, --> R (0) : BACKLIGHT OFF R(1): Backlight On
Z(4) : FLICKERLESS ON state, --> R (0) : FLICKERLESS OFF R(1): Flickerless on
Z(8) : Auto BLC Mode, --> R (0) : Auto BLC Off Mode R(1): Auto BLC On Mode
ONZ-AN101/151/102/152, AP101/151/102/152 Specifications
ONIX SYSTEM INC.
13) BACKLIGHT Level Read *XX83XXXXYY
Read the current BACKLIGHT level of Camera . *XXZZXXXXYY ;return Data
ZZ : BACKLIGHT level. (data range 00 ~FF hex)
16) SHUTTER Speed Setting *XX86ZZXXYY
Set the shutter speed with the “shutter counter” . ZZ :shutter counter
14) BACKLIGHT Level Adjust *XX84ZZXXYY
Adjust the current BACKLIGHT level of Camera . ZZ: BACKLIGHT level.
(data range 00 ~FF hex)
15) SHUTTER Speed counter read *XX850000YY
Set the shutter speed with the “shutter counter” . *XX85ZZ00YY ;return data
ZZ : shutter counter
00 : 1/60 01:1/125 02:1/250 03:1/200
04 : 1/250 05:1/300 06:1/350 07:1/400
08 : 1/450 09:1/500 10:1/600 11:1/700
12 : 1/800 13:1/900 14:1/1000 15:1/1100
16 : 1/1200 17:1/1300 18:1/1500 19:1/1600
20 : 1/1800 21:1/2000 22:1/2500 23:1/3000
24 : 1/3500 25:1/4000 26:1/6000 27:1/10000
17) AGC Level Setting *XX87ZZXXYY
Set the AGC Level with the AGC data .
ZZ: AGC data
00(Minimum AGC Level) ~ FF Hex (Maximum AGC Level)
18) Read the current BRIGHTNESS data *XX88XXXXYY
Read the current BRIGHTNESS data of the Camera. *XXZZXXXXYY ;return data
The return data is “Brightness”.
ZZ : 00(Minimum Brightness level) ~ 60 Hex (Maximum Brightness Level)
19) Read the IRIS control data *XX89XXXXYY *XXZZXXXXYY ;return data
ZZ : IRIS Control Level (data range 00 ~FF hex)
5/10
ONZ-AN101/151/102/152, AP101/151/102/152 Specifications
ONIX SYSTEM INC.
20) IRIS Level Setting *XX8AZZXXYY
Set the IRIS OPEN Level
ZZ : IRIS control level (data range 00 ~FF hex)
21) Read the AGC control data *XX8B0000YY *XXZZ0000YY ;return data ZZ : Current AGC Control level (data range 00 ~FF hex)
22) IRIS Area Weighting Value Read *XX8EXXXXYY
Read the current weighting value of Iris area. *XXABXXXXYY ;return data
A:Region 1 weight data
B:Region 2 weight data
24) FLICKERLESS Mode ON/OFF Setting *XX900ZXXYY
Z(1) : Flickerless Mode Active
Z(0) : Flickerless Mode inactive
6/10
23) IRIS Area Weighting Value Write *XX8FXXXXYY
Read the current weighting value of Iris area.
A:Region 1 weight data
B:Region 2 weight data
25) BRIGHTNESS Data Setting *XX91ZZXXYY
ZZ : Brightness level desired (data range 00 ~ 60 hex)
26) Read the White Balance Mode *XXB1XXXXYY
Read the current White Balance Mode of the Camera. *XX0ZXXXXYY ;return data
Z(0) : Auto Mode Z(1) : Special Z(2) : indoor Z(3) : outdoor
Z(4) : Manual Z(5) : Push Auto
27) White Balance Mode Set Command *XXB20ZXXYY
Set the mode of White Balance of the camera.
Z(0) : Auto Mode Z(1) : Special Z(2) : indoor Z(3) : outdoor
Z(4) : Manual Z(5) : Push Auto
28) Read the current MANUAL White Balance Mode data *XXB3XXXXYY *XXB3ZZXXYY ;return data ZZ : (data range 00 ~60 hex)
R1 R2
ONZ-AN101/151/102/152, AP101/151/102/152 Specifications
ONIX SYSTEM INC.
29) MANUAL White Balance Mode MWB_CTL data Setting *XXB4ZZXXYY ZZ : (data range 00 ~60 hex)
30) Read the current SHARPNESS data *XXB5XXXXYY *XXB50ZXXYY ;return data
Z : “Sharpness Data” Data value range 0 ~ F
32) Read the RED Adjust data at the SPECIAL White Balance Mode *XXB7XXXXYY
*XXZZXXXXYY ;return data
ZZ : Red adjust data (data range 00 ~ FF hex)
33) Read the BLUE Adjust data at the SPECIAL White Balance Mode data *XXB8XXXXYY
*XXB8ZZXXYY ;return data
ZZ : Blue adjust data. (data range 00 ~ FF hex)
34) SPECIAL White Balance Mode RED adjust data Setting *XXB9ZZXXYY
ZZ : Red adjust data (data range 00 ~FF hex)
31) SHARPNESS data adjust *XXB60ZXXYY
Z : “Sharpness Data” Data value range 0 ~ F
7/10
35) SPECIAL White Balance Mode BLUE adjust data Setting *XXBAZZXXYY
ZZ : Blue adjust data (data range 00 ~FF hex)
36) Zoom Lens Position Read *XXC0XXXXYY
*XX0ABCDEYY ;return data
A : ZOOM POSITION HIGH
BC : ZOOM POSITION LOW
DE : DIGITAL ZOOM POSITION
* zoom position range ( 00 ~ 42F Hex)
* Digital zoom position range ( 00 ~ E0 Hex )
* : This command is used For Zoom Position setting In
external PRESET mode . ABCDE is expressed in Hex data
37) Focus Lens Position Read *XXC1XXXXYY
*XX0ABCXXYY
A : FOCUS POSITION HIGH
BC : FOCUS POSITION LOW
* focus position range ( 3F ~ 315 Hex)
* : This command is used For Zoom Position setting
In external PRESET mode . ABC is expressed in Hex data
ONZ-AN101/151/102/152, AP101/151/102/152 Specifications
ONIX SYSTEM INC.8/10
38) Memorize Internal PRESET Position for Internal PRESET control *XXC7ZZXXYY
Memorize the current zoom, focus, and digital zoom position
value into the internal nonvolatile memory of the CAMERA
for controlling the Internal PRESET Move. The memory position
to store is indicated by the “INDEX” value.
ZZ : (data range 00 ~ 3F hex) : Index counter
39) Internal Non Zoom Tracking PRESET Moving control *XXC8ZZXXYY
Perform the Internal PRESET Moving action.
ZZ : (data range 00 ~ 3F hex) : Index counter
40) Slow Speed Internal Zoom Tracking PRESET Moving control :XXCFZZXXYY
Perform the Zoom Tracking PRESET action to the target zoom
position slowly. The target zoom position value is memorized in the
internal nonvolatile memory.
ZZ : (data range 00 ~ 3F hex) : Index counter
41) Quick Speed Internal Zoom Tracking PRESET Moving control :XXD0ZZXXYY
Perform the Zoom Tracking PRESET action to the target zoom
position Quickly. The target zoom position value is memorized in the
internal nonvolatile memory.
ZZ : (data range 00 ~ 3F hex) : Index counter
CF) Internal Preset Mode usage 1. Using “Memorize Internal PRESET Position “ Command , Memorize each position To camera 2. Using “Preset Moving control “ Command , Move Zoom and Focus Lens to each Memorized position every position is accessed by index counter
ONZ-AN101/151/102/152, AP101/151/102/152 Specifications
ONIX SYSTEM INC.
Appendix: Key Code Table 1/2
KC_STOP 09 ; After the other key commands below this command must be followed after.
If continuous key service is needed send this command several seconds
after the before command.
In other words , when you want a certain function you can send below key codes
when you want to stop the function send this command again.
KC_POWER 0A ; Toggles power on/off status
KC_TELE 01 ; Slow zoom tele action
KC_WIDE 03 ; Slow zoom wide action
KC_QTELE 02 ;Fast zoom tele action
KC_QWIDE 04 ; Fast zoom wide action
KC_FAR 05 ;Focus lens move action to far direction ( in manual focus mode)
KC_NEAR 06 ;Focus lens move action to near direction ( in manual focus mode)
KC_FAM 0B ;Toggles focus Auto/Manual Modes
KC_F_PUSH 0C ; Activates Focus auto action on time
KC_SET 0D ; In menu mode , toggles item selection mode/ item adjust mode
KC_Default 0E ; by this code all conditions in camera returns to manufacturer’s conditions
KC_OSD 0F ; Toggles function osd off/on modes
KC_MENU 10 ; Toggles menu on/off modes
KC_BL 13 ; Toggles backlight mode
KC_FLICKER 14 ; Toggles flicker mode
KC_SSC Up 15 ; Shutter speed counter up
KC_SSC Down 16 ; Shutter speed counter down
KC_DEFT 17 ;Switches digital effect modes WIDE→ART → MIRROR → NEGA80
MONO → MOSAIC
KC_MIRROR Con. 18 ;Toggles Mirror mode
KC_NEGA 19 ;Toggles nega mode
KC_MONO 1A ;Toggles mono modeKC_WIDE 38 ; Toggles wide modeKC_MOSAIC 39 ;Toggles mosaic modeKC_ART 3A ; Toggles art mode
9/10
ONZ-AN101/151/102/152, AP101/151/102/152 Specifications
ONIX SYSTEM INC.
Appendix: Key Code Table 2/2
KC_SRPUP 1C ;sharpness data up
KC_SRPDN 1D ;sharpness data down
KC_BRTUP 1E ;Brightness data up
KC_BRTDN 1F ;Brightness data down KC_ZoomSup 20 ;Zoom Start upKC_ZoomSdn 21 ;Zoom Start downKC_ZoomEup 22 ;Zoom End upKC_ZoomEdn 23 ;Zoom End down
KC_WB_PUSH 24 ;In white balance push auto mode (manual mode ) ,initiates “push action”KC_AWBup 25 ;Switches awb modes auto → special → Indoor → outdoor → hue control → puah autoKC_AWBdn 26 ;Switches awb modes in reverse sequence to KC_AWBupKC_RadjUP 27 ;In Special WB mode ,R gain goes upKC_RadjDN 28 ;In Special WB mode ,R gain goes downKC_BadjUP 29 ;In Special WB mode ,B gain goes upKC_BadjDN 2A ;In Special WB mode ,B gain goes downKC_HUEUP 2B ;In HUE adjust WB Mode the picture become ReddishKC_HUEDN 2C ;In HUE adjust WB Mode the picture become BluishKC_AE_Man 2D ;Turns AE mode to Manual modeKC_IrisUp 2E ;Increase IRIS LevelKC_IrisDn 2F ;Decrease IRIS LevelKC_AGCup 30 ;Increase AGC GainKC_AGCdn 31 :Decrease AGC gain
END
Example of Key action transfer
# Zoom Lens moving example
Send commands following this sequence! 1 → 2 → 3
Every codes are transferred and received in ASCII codes
1. *XX75ZZXXYY ( move to tele )
XX=don’t care
ZZ = 01 (KC_TELE)
YY=Check Sum Data
=>assume XX to be 00 ,then the check sum becomes Y Y
2A(‘*’) + 30(‘0’)+ 30(‘0’)+37(‘7’)+35(‘5’)+ 30(‘0’)+ 31(‘1’)+30(‘0’)+ 30(‘0’) = ‘B’ ‘7’
2. Software delay ( The time you desired to move )
3. *XX75ZZXXYY (stop action )
ZZ:09 (KC_STOP)
10/10