GOST - R
GOST
Baumer
Special Features
Application
Specifications
Standard Version : 100 mm
:
:
:
:
AZHomogenizer Pressure GaugeDiaphragm type
Page 1 / 4
31-
08 -
12 D
esi
gn a
nd s
peci
ficatio
ns
subje
ct to c
hange w
ithout notic
e
www.baumer.com
& Atex approved electrical contacts
Laser welded diaphragm
Filled version facilitate usage in vibration Zones
to avoid damages to its mechanism.
Suitable for homogenizer machines.
Electrical contact options available.
Standard followed in general EN 837-3.
These gauges are being used in applications where
Hygiene is of prime importance like dairy
Food
Ice cream
Beverages
Pharmaceutical industries
Sterilization.
Protection
Dial
Pointer
Window
Blow off Disc
Gasket & Filling plug
Sealing liquid
Dampening Liquid
IP 65
Aluminum, black graduation on white background
Aluminum, black coloured micrometer zero adjustable
Plexi Glass
Neoprene
Neoprene
Glycerin
Glycerin 99.7%
AISI 304 SS (Bayonet Type)
AISI 316L SS
AISI 316L SS
AISI 304 SS
AISI 316L SS
AISI 316 SS
Tig Argon Arc Welding
Case & Bezel
Bourdon
Socket
Movement
Diaphragm
Body
Joints
Accuracy
Ambient temperature
Process temperature
Operating pressure range
±1.6% of F. S.
- 25°C to + 65°C
Max. 120°C
75% of Scale Value
Electrical contacts - dry version
Accuracy
Ambient Temperature
Process Temperature
Window
Dampening Liquids
Electric Contacts*
Other Features
±2.5% of F. S.
Maximum 65°C oMaximum 65 C
Polycarbonate Dome
Dielectric Oil (Optional)
Refer How to Order
Refer Specification of Standard Version
Temperature effect:
The variation of indication caused by effects of temperature is to be calculated by below formula; which is to be added in the specified accuracy
while measurement :- Formula : ± 0.08 x (t2 - t1) % of F. S. where t1 = reference temperature (+20°C) and t2 = ambient temperature in °C.
* Please specify contact set points while ordering.
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
23
14
Closing 1
Closing 24 13 2++ - -
1 NC + 1 NC
23
14
Opening 1
Closing 241 3 2+ +- -
1 NO+ 1 NC
Opening 1
Opening 2
31 2
1
3
2
1 NO + 1 NO
Closing 2
Opening 1
33 21
2
3
1
1 NC + 1 NO
Opening 1
1
3
2
Closing 2
1 3 2
1 NO + 1 NC
33 12
Closing 1
Closing 2
1
3
2
1 NC + 1 NC
13
Opening
1 3
1 NO
23
23
Closing
1 NC
31-
08 -
12 D
esi
gn a
nd s
peci
ficatio
ns
subje
ct to c
hange w
ithout notic
e
www.baumer.com
Baumer AZ
Range Table
Wiring diagrams for electric contacts
Single Contact
Double contact
Independent double contact
Homogenizer Pressure GaugeDiaphragm type
Page 2 / 4
E
L
ØF
ØG
37.5000
ØH
A
ØD ØC
B
ØIØJ
MK
N
P
O
TYPE H02
ØF
ØG
H
ØJ
ØI
ØK
ØM
E
N
ØCØD
B
A
O
P
L
TYPE H01
C
A
ØD Ø
B
M
O
ØI
ØJ
ØF
G
L
H
N
K
E
TYPE H03
Notes : • Drawings are not to scale. • All Dimensions are in mm. • NS = Nominal Size
Baumer AZHomogenizer Pressure GaugeDiaphragm type
Dimensions - standard version
11/4” BSP(F) Connection
ØF
27100 12.5
NS A
47 100 111 22
B ØC ØD E
10
ØJ
23.5A/F 5044 34
HG ØI
1011¼"BSP(F) 10
L NM
8585
PO
1300.0
KWeight in gram
(With Box)
Flange Connection
ØF
22100 12.5
NS A
47 100 111 22
B ØC ØD E
45
ØJ
352818 24
HØG ØI
9060 95
L NØM
6.513
PO
1600.0
ØKWeight in gram
(With Box)
Without Flange Connection
ØF
21100 12.5
NS A
47 100 111 22
B ØC ØD E
34
ØJ
342631 37.5
HØG ØI
89.510 10.3
L NØM
824.2
PO
1200.0
ØKWeight in gram
(With Box)
Page 3 / 4www.baumer.com
31-
08 -
12 D
esi
gn a
nd s
peci
ficatio
ns
subje
ct to c
hange w
ithout notic
e
Baumer AZHomogenizer Pressure GaugeDiaphragm type
Page 4 / 4www.baumer.com
31-
08 -
12 D
esi
gn a
nd s
peci
ficatio
ns
subje
ct to c
hange w
ithout notic
e
RANGE (in kg/cm² or bar)
FlangeH01
0/160* 0/600*
H02 With out flange (Standard) 1¼" BSP (F)H03
0/250* 0/400 (Standard)
*Consult factory for price & delivery.
Filling Fluids
UF 0 0 Glycerin [10 to 150 C / 50 to 302 F] (Standard) 0 0 Food grade oil [-20 to 140 C / -4 to 284 F]UV
Type of Mounting
Code
Nominal Size
Basic Model
2
F
100 mm
Direct bottom entry
Optional extras
Gauge Connection
Five point calibration certificate
SS tag plate
Maximum reading pointer with plexi glass
(for dry version)
PW
SX
SJ
Helium leak test
Custom designed dial
Material test certificates*
Dielectric oil filled**
TB
RH
GH
ZZ
Electric Contacts ( & Atex Approved)
(For dry version, with ingress protection up to IP 55 & poly carbonate dome as a window.)
A) Single insulated magnetic snap action type
(230 V AC, 1 Amp.)(48 V DC, 0.5 Amp.) B) Inductive Type (220 V AC, 0.4 Amp.)
*Material test certificates will be provided for wetted parts only with chemical composition testing. For others, please consult factory.
**BOD, gasket & filling plug Viton.
DAMPENING LIQUIDS: CODE
Single; normally closed (1 NC)
Double; normally closed + normally open (1 NC +1 NO)
Single; normally open (1 NO)
Double; normally open + normally closed (1 NO + 1 NC)
Double; normally closed (both NC)
Double; normally open (both NO)
Booster with relay for current upto 5 Amp.
RJ
RK
RL
RM
RN
RO
RU
YW
YV
YX
YY
YZ
RA
RC
SPDT
DPDT
Single; normally open (1 NO)
Single; normally closed (1 NC)
Double; normally closed + normally open (1 NC +1 NO)
Double; normally open (both NO)
Double; normally closed (both NC)ZA Double; normally open + normally closed (1 NO + 1 NC)
Ordering Example: AZ . X . X . XXX . 0-250 . XX . XXFor other optional items, please contact factory for delivery and minimum quantity of order.Note : Specifications and dimensions given in this product catalogue represents the state of engineering at the time of printing . Modifications may take place and materials specified may be replaced by others without prior notice.
X
AZ
X
XXX
0/250
XX
XX
How To Order Example