∗ Air cost: 3 Yen/m3
Air-flow volume is determined by theeffective area, not the nozzle diameter.
A large effective area means that the blow gun can beused with less pressure for the required job.
This means it is possible to use with less air consumption.In addition, the environmentally friendly low noise nozzle
is also available.
Produces less noiseby dividing the
air-blow slit.
80 dB or lessLow-noise nozzle
Series VMG
VMG 506
570
650
3,038
3,420
3,936
6,0776,8407,871
ø2
ø2.5
ø3
30
6
6
211
237.5
273.3
+ 763+1,794
+ ¥2,289+ ¥5,382
Energysaving
Noisereduction
Forexample
Blow Gun
Reduction of
annum is possible.2,000 m3 per
Reduction of
annum is possible.2,000 m3 per
Conventional model A Conventional model B
Pressure loss 1% or less
Pressure loss 1% or less
(Nozzle diameter: ø
2.5)
CAT.ES50-20C
Nozzlediameter 1 month 6 months 12 months Air consumption (m3) Cost
Air consumption (m3) Amount difference (12 months)Effectivearea (mm2)
Consumption flow
(dm3/min (ANR))
Valve Construction and Pressure Loss
Comparison by Switchover
Straighter flowing fluid “improves pressure loss.”
PAT.PEND
Series VMG
Pressure Loss
0 0.2 0.4 0.6 0.8 1
Supply pressure (MPa)
Pre
ssur
e lo
ss (
MP
a)
0 30 60 90 120 150 1800
4,000
6,000
8,000
10,000
12,000
14,000
16,000∗ Air cost: 3 Yen/m3
0
1,000
2,000
3,000
4,000
5,000
6,000
7,000
8,000
9,000
0 30 60 90 120
150
180
210
240
270
300
330
360
Air consumption comparison (per blow gun)
Approx. 2,000 m3
differencein 365 days
Approx. 1,000 m3
differencein 365 days
VMGConventional model AConventional model B
� VMG11W-02-03Effective area 30 mm2
Nozzle diameter ø2
� Conventional model AEffective area 6 mm2
Nozzle diameter ø2.5
� Conventional model BEffective area 6 mm2
Nozzle diameter ø3
• Workpiece impact pressure: 0.01 MPa• Workpiece distance: 100 mm• Piping: TU0805-3 m• Blow time: 30 s/times• Blow frequency: 10 times/h• Working hours: 16 hrs/day
0
0.1
0.05
0.15
0.2
0.25
0.3 VMG(Nozzle diameter: ø2.5)
Pressure loss: 0.005 MPa or less with 0.5 MPa
Model
Condition
Cos
t (Y
en)
Days
Air
cons
umpt
ion
(m3 )
Days
Total cost comparison (Blow gun purchase price + Air cost)
Breakeven withconventional model B
Breakeven withconventional model A
Conventional construction
Energy savingvalve construction
Balance-poppet valve construction
Conventional model AConventional model B
Features 1
Example of Air Blow Improvement
ø2.5
Filterregulator
S couplerCoiltube
Nozzleø2.5
Effective arearatio
1 : 1.33
S2S0 to S1
Effective arearatio
3.3 : 1
S2S0 to S1
When using the air gun, energy-saving measures are rarely taken.
ø3
Pressure loss
Large
Nozzleø3
Pressure loss
Small
After improvementBefore improvement
Reduced pressure loss for the whole system Reduced air consumption
95%95%
Reduced bymore than Reduced bymore than
After improvementBefore improvement
Effective area ratio (S0 to S1 : S2)
Regulator pressure
Air gun pressure (idling)
Outlet pressure
Air consumption
TCU0805 coil tube
Conventional model
ø3
6.8 mm2
6 mm2
6.3 mm2
1 : 1.33
0.3 MPa
0.255 MPa
0.177 MPa
210.7 dm3/min (ANR)
0.123 MPa
0.078 MPa
Piping
Air gun
Nozzle size
Piping (S0)
Air gun (S1)
Nozzle (S2)
Whole system
Air gun single unit
After reviewing the air-blow job, changing the fittings, tube and blow gun create a larger effective area.
10%10%
Operatingequipment
Effectivearea
Effective area ratio (S0 to S1 : S2)
Regulator pressure
Blow gun pressure (idling)
Outlet pressure
Air consumption
TCU1065�-1-20-X8 coil tube
Series VMG1
ø2.5
14.8 mm2
30 mm2
4.4 mm2
3.3: 1
0.26 MPa
0.254 MPa
0.252 MPa
186.6 dm3/min (ANR)
0.008 MPa
0.002 MPa
Piping
Blow gun
Nozzle size
Piping (S0)
Blow gun (S1)
Nozzle (S2)
Whole system
Blow gun single unit
Operatingequipment
Reduced bymore than
Reduced bymore than
Features 2
Reduced bymore than
Reduced bymore than
Beforeimprovement
Afterimprovement
Pressureloss
Effectivearea
Pressureloss
Operability, Safety, Environmentally
Dark blue White
Piping direction
Bottom
Top
Body color
White
Dark blue
Piping type
With S coupler plug
Rc, NPT, G 1/4, 3/8
NozzlesHand-fit Design34 Types in Nozzle VariationHand-fit Design34 Types in Nozzle VariationHand-fit Design34 Types in Nozzle Variation
Low-noise nozzleMono-porous nozzle (ø2) 90 to 100 dBø1 x 4 low noise nozzle 80 dB or lessNote) Supply pressure: 0.5 MPa
Measured at a 45 degree angle according to JIS B 8379
∗ Achieving lower-noise by dividing the air blow slit.
∗ Powerful, and economical.
Male thread nozzle
∗ Making use of Bernoulli effect andachieving high-efficiency.
High-efficiency nozzle
∗ Secures large power even at a greaterdistance from a workpiece.
Copper extension nozzle
Resin:PBT
Seals:NBR
Nozzle:Brass
Metal:Aluminum
alloyStainless
steel Recyclable
When using this product even at a high pressure the same gripping force is required as for a lower pressure due to the unique balance-poppet construction.
When using this product even at a high pressure the same gripping force is required as for a lower pressure due to the unique balance-poppet construction.
Resin parts are labeled with their material composition for easy identification. In addition, all components are separable according to their material composition.
Resin parts are labeled with their material composition for easy identification. In addition, all components are separable according to their material composition.
Shock-resistant resin is used in the main body. No cracks, breaks or other damage occurred in a drop test from a 2-meter height or in a human stomp test.
Shock-resistant resin is used in the main body. No cracks, breaks or other damage occurred in a drop test from a 2-meter height or in a human stomp test.
Features 3
Components can be separated for recycling.
Not affected by supply pressure,Assured operability
Use of shock-resistant resin
Air blowAir blow
70%
� First, check your blow gun.Most blow guns in use have an effective area of about 6 mm2.
� Furthermore, energy can be saved using a comprehensive air-blow system.
etc.
Lowerpressure
loss
Use withlower
pressure.
Lowerair con-
sumption
Reducedpower con-sumption
Largeeffective
area
Reducedcost
If a blow gun with alarger effective area is used.
Air leakage measures Improvement of pressure loss High-efficiency
S coupler achieves a smooth flow with less lossUrethane coil tube
Male thread nozzle
High efficiency nozzle
Low noise nozzlewith male thread
Copper extension nozzle
Blow gunPiping length: 1 m
Coil tube
Tube diameter
S coupler
Model
Piping length: 2 mCoil tube
Tube diameter
S coupler
Model
ø6
ø6
ø8
ø10
ø6
ø6
ø8
ø6
ø10
ø8
ø10
ø6
ø8
ø6
ø8
KK4S-06�KK4S-06�KK4S-08�KK4S-10�KK4S-06�KK4S-06�KK4S-08�KK4S-06�KK4S-10�KK4S-08�KK4S-12�KK4S-06�KK4S-08�KK4S-06�KK4S-08�
ø6
ø8
ø10
ø12
ø6
ø8
ø10
ø6
ø12
ø10
ø12
ø8
ø10
ø8
ø10
KK4S-06�KK4S-08�KK4S-10�KK4S-12�KK4S-06�KK4S-08�KK4S-10�KK4S-06�KK4S-12�KK4S-10�KK4S-12�KK4S-08�KK4S-10�KK4S-08�KK4S-10�
ø1
ø1.5
ø2
ø2.5
ø1
ø1.5
ø2
ø0.75 x 4
ø0.9 x 8
ø1 x 4
ø1.1 x 8
ø1.5-300 mm
ø2-300 mm
ø1.5-600 mm
ø2-600 mm
Nozzle type Nozzle diameter
Example of air consumptioninside the factory
“Why not use wasted air?”
Air leakage20%
Actuation
10%The power consumption for air (compressor) consumed in the factory is accounting for 20%. An estimated 70% of total air con-sumption is used for air blowing.Why not review your air con-sumption?
But the SMC model has
an of .
etc.
Selection Table for Blow Gun Nozzle Diameter and Tube ∗ Recommended system in accordance with the nozzle type
Features 4
Blow gun
VMG 1
Series
1 03 01W
Standard type
Male thread nozzle
High efficiency nozzle
Low noise nozzlewith male thread
Copper Note)
extensionnozzle
Specifications
Fluid
Operating pressure range
Proof pressure
Ambient and fluid temperature
Effective area
Port size
Piping entry
Nozzle port size
Weight
Operational force (when the valve is fully open)
Air
0 to 1.0 MPa
1.5 MPa
�5 to 60�C (No freezing)
30 mm2 (without nozzle)
Rc, NPT, G 1/4, 3/8
Rc 1/4
180 g
7 N
Bottom Top
Note) One piece of H06-02 self-align fitting is attached.When a copper extension nozzle is ordered separately, a self-align fitting will also be required for connection. Order one with the above part number in addition to the nozzle.
Note) In the case of a type with an S coupler plug, specify no symbol (Rc) for the piping connection type. The size is Rc 1/4.
Resin body lever type1
Body colorWhite
Dark blue
WBU
Piping entryBottom
Top
12
Piping connection typeRc
NPT
G
Nil
NF Connection size
Size and part no.Piping connection system
Screw-in type
With S coupler plug Note)
1/4
3/8
KK4P-02MS
020311
NozzleType Nozzle model
Without nozzle
KN-R02-100
KN-R02-150
KN-R02-200
KN-R02-250
KNH-R02-100
KNH-R02-150
KNH-R02-200
KNS-R02-075-4
KNS-R02-090-8
KNS-R02-100-4
KNS-R02-110-8
KNL3-06-150
KNL3-06-200
KNL6-06-150
KNL6-06-200
Nozzle size
ø1
ø1.5
ø2
ø2.5
ø1
ø1.5
ø2
ø0.75 x 4
ø0.9 x 8
ø1 x 4
ø1.1 x 8
ø1.5
ø2
ø1.5
ø2
Nil010203041112132122232431323334
Length300 mm
Length600 mm
Port size
Plug part no.
1
Series VMGBlow Gun
How to Order
1234567891011121314151617181920
Body L
Body R
Main valve
Valve guide
Nozzle holder
Port
Elbow
Cover
Ring
Arm L
Arm R
Spring
Main valve seal
Lever
Piping (bottom)
O-ring
O-ring
Parallel pin
Cross recessed round head screw
Hexagon nut
Material
Chromated
Anodized
Anodized
∗Only for VMG11�
PBT
PBT
PBT
Aluminium alloy
Aluminium alloy
Aluminium alloy
PBT
PBT
PBT
PBT
PBT
Stainless steel
HNBR
PBT
POM
NBR
NBR
Stainless steel
Stainless steel
Stainless steel
Note
Component Partsi
y
ureq w
o
t
!3!7!2
!5
!6!1 !0
!8
@0 !9
!4
600
500
400
300
200
100
00.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
KN-R02-250
KN-R02-200
KN-R02-100
400
350
300
250
200
150
100
50
0
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
KNH-R02-200
KNH-R02-150
KNH-R02-100
400
350
300
250
200
150
100
50
0
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
KNL3-06-200
KNL3-06-150
KNL6-06-200
KNL6-06-150
900
800
700
600
500
400
300
200
100
0
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
KNS-R02-110-8
KNS-R02-090-8
KNS-R02-100-4
KNS-R02-075-4
Supply pressure [MPa] Supply pressure [MPa]
Flo
w r
ate
[l/m
in (
AN
R)]
Supply pressure [MPa]
Flo
w r
ate
[l/m
in (
AN
R)]
Supply pressure [MPa]
Flo
w r
ate
[l/m
in (
AN
R)]
Male thread nozzle High efficiency nozzle
Low noise nozzle with male thread Copper extension nozzle
KN-R02-150
Note) Grease is used on rubber and sliding sections.
Note) Values when the main valve is fully open.
DescriptionNo.
Construction
Flow Characteristics
Flo
w r
ate
[l/m
in (
AN
R)]
2
Blow Gun Series VMG
23
23
A
172.
5
34.2
30
147
117.5
102
A
30
156
117.5
102
Rc, NPT, G 1/4, 3/8
Rc, NPT, G 1/4, 3/8
Rc 1/4
Width across flats 22
Nozzle
Rc 1/4
Type Nozzle model
Male thread nozzle
High efficiency nozzle
Nozzle size A Note)
34.2
Not
e)
Note) Reference dimensions after installation
(mm)
Nozzle
KN-R02-100
KN-R02-150
KN-R02-200
KN-R02-250
KNH-R02-100
KNH-R02-150
KNH-R02-200
ø1
ø1.5
ø2
ø2.5
ø1
ø1.5
ø2
23.4
23
22.5
22.1
44
44
44
Type Nozzle model
Low noise nozzle with male thread
Copper extension nozzle (with self-align fitting H06-02)
Nozzle size A Note)
(mm)
KNS-R02-075-4
KNS-R02-090-8
KNS-R02-100-4
KNS-R02-110-8
KNL3-06-150
KNL3-06-200
KNL6-06-150
KNL6-06-200
ø0.75 x 4
ø0.9 x 8
ø1 x 4
ø1.1 x 8
ø1.5
ø2
ø1.5
ø2
12
12
12
12
305.3
305.3
605.3
605.3
Dimensions
S coupler plug mounting
Not
e)
Width across flats 22
VMG12/Piping entry: Top
S coupler plug mounting
3
VMG11/Piping entry: Bottom
Series VMG
øD
L1
A
L1
øD
H1
Connection thread
øD
2
A
L1
Connection threadH1
AL1
øD
H1
Connection thread
KNL3-06-150A02KNL3-06-200A02KNL6-06-150A02KNL6-06-200A02
KNL3-06-150 (1 pc.)KNL3-06-200 (1 pc.)KNL6-06-150 (1 pc.)KNL6-06-200 (1 pc.)
Description
H06-02-X2 (1 pc.)H06-02-X2 (1 pc.)H06-02-X2 (1 pc.)H06-02-X2 (1 pc.)
(mm)
KN-R02-100KN-R02-150KN-R02-200KN-R02-250
ø1ø1.5ø2ø2.5
R 1/4R 1/4R 1/4R 1/4
14141414
31.431 30.530.1
25.425 24.524.1
∗ Reference dimensions after R thread installation.
L1 A∗H1
(mm)
KNH-R02-100KNH-R02-150KNH-R02-200
ø1ø1.5ø2
R 1/4R 1/4R 1/4
141414
525252
464646
∗ Reference dimensions after R thread installation.
L1 A∗H1
Low noise nozzle with male thread: KNS (mm)
KNS-R02-075-4KNS-R02-090-8KNS-R02-100-4KNS-R02-110-8
ø0.75 x 4ø0.9 x 8ø1 x 4ø1.1 x 8
R 1/4R 1/4R 1/4R 1/4
14141414
20202020
14141414
Model
∗ Reference dimensions after R thread installation.
Nozzle sizeD
Connectionthread L1 A∗Width across flats
H1
Copper extension nozzle: KNL (mm)
KNL3-06-150KNL3-06-200KNL6-06-150KNL6-06-200
ø1.5ø2ø1.5ø2
300300600600
ø6ø6ø6ø6
Model Outside diameterNozzle size
D L1
Nozzle Self-align fittings
Male thread nozzle: KN
Dimensions: Nozzle/Series KN
ModelNozzle size
DConnection
threadWidth across flats
High efficiency nozzle: KNH
ModelNozzle size
DConnection
threadWidth across flats
Out
side
diam
eter
Note) When a copper extension nozzle is ordered separately, a self-align fitting will also be required for connection with the blow gun. Order one with the following part number in addition to the nozzle.
Self-align fittings (For copper extension nozzle connection)
Male connectorH06-02-X2
Set no.
4
Blow Gun Series VMG
Back page 1
Safety InstructionsThese safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of “Caution,” “Warning” or “Danger.” They are all important notes for safety and must be followed in addition to International Standards (ISO/IEC)∗1), and other safety regulations.∗1) ISO 4414: Pneumatic fluid power – General rules relating to systems.
ISO 4413: Hydraulic fluid power – General rules relating to systems.IEC 60204-1: Safety of machinery – Electrical equipment of machines. (Part 1: General requirements)ISO 10218-1: Manipulating industrial robots - Safety.etc.
1. The compatibility of the product is the responsibility of the person who designs the equipment or decides its specifications.Since the product specified here is used under various operating conditions, its compatibility with specific equipment must be decided by the person who designs the equipment or decides its specifications based on necessary analysis and test results. The expected performance and safety assurance of the equipment will be the responsibility of the person who has determined its compatibility with the product. This person should also continuously review all specifications of the product referring to its latest catalog information, with a view to giving due consideration to any possibility of equipment failure when configuring the equipment.
2. Only personnel with appropriate training should operate machinery and equipment.The product specified here may become unsafe if handled incorrectly. The assembly, operation and maintenance of machines or equipment including our products must be performed by an operator who is appropriately trained and experienced.
3. Do not service or attempt to remove product and machinery/equipment until safety is confirmed.1. The inspection and maintenance of machinery/equipment should only be performed after measures to prevent falling
or runaway of the driven objects have been confirmed. 2. When the product is to be removed, confirm that the safety measures as mentioned above are implemented and the
power from any appropriate source is cut, and read and understand the specific product precautions of all relevant products carefully.
3. Before machinery/equipment is restarted, take measures to prevent unexpected operation and malfunction.
4. Contact SMC beforehand and take special consideration of safety measures if the product is to be used in any of the following conditions. 1. Conditions and environments outside of the given specifications, or use outdoors or in a place exposed to direct
sunlight.2. Installation on equipment in conjunction with atomic energy, railways, air navigation, space, shipping, vehicles, military,
medical treatment, combustion and recreation, or equipment in contact with food and beverages, emergency stop circuits, clutch and brake circuits in press applications, safety equipment or other applications unsuitable for the standard specifications described in the product catalog.
3. An application which could have negative effects on people, property, or animals requiring special safety analysis. 4. Use in an interlock circuit, which requires the provision of double interlock for possible failure by using a mechanical
protective function, and periodical checks to confirm proper operation.
Warning
Caution:
Danger :
Warning:
Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury.
Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury.
Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury.
Back page 2
Safety Instructions
Limited warranty and Disclaimer/Compliance Requirements The product used is subject to the following “Limited warranty and Disclaimer” and “Compliance Requirements”.Read and accept them before using the product.
1. The product is provided for use in manufacturing industries.The product herein described is basically provided for peaceful use in manufacturing industries. If considering using the product in other industries, consult SMC beforehand and exchange specifications or a contract if necessary. If anything is unclear, contact your nearest sales branch.
Caution
Limited warranty and Disclaimer
1. The warranty period of the product is 1 year in service or 1.5 years after the product is delivered.∗2)
Also, the product may have specified durability, running distance or replacement parts. Please consult your nearest sales branch.
2. For any failure or damage reported within the warranty period which is clearly our responsibility, a replacement product or necessary parts will be provided. This limited warranty applies only to our product independently, and not to any other damage incurred due to the failure of the product.
3. Prior to using SMC products, please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products.
∗2) Vacuum pads are excluded from this 1 year warranty.A vacuum pad is a consumable part, so it is warranted for a year after it is delivered. Also, even within the warranty period, the wear of a product due to the use of the vacuum pad or failure due to the deterioration of rubber material are not covered by the limited warranty.
Compliance Requirements1. The use of SMC products with production equipment for the manufacture of weapons of mass destruction (WMD) or
any other weapon is strictly prohibited.
2. The exports of SMC products or technology from one country to another are governed by the relevant security laws and regulations of the countries involved in the transaction. Prior to the shipment of a SMC product to another country, assure that all local rules governing that export are known and followed.
Male thread
R 1/4
R 3/8
Tightening torque N⋅m
12 to 14
22 to 24
PortSpanner
Wrapping direction
Pipe tape
Expose approx. 2 threads
Back page 3
Nozzle tightening torque range 12 to 14 N �m
Nozzle holderSpanner
Insufficient tightening may cause loosening of the nozzle.
1. Do not apply the blow gun to flammable, explosive or toxic substances such as gas, fuel gas or refrigerant. Such substances may exude from inside the blow gun.
1. Install a stop valve on the supply pressure side of the blow gun to enable emergency shut off in case of unexpected leakage or damage.
2. When installing a nozzle on the blow gun, wrap seal tape around the threads of the nozzle.
3. When installing the nozzle, secure the nozzle holder of the blow gun by applying a spanner of 22 mm width across flats to the two chamfered surfaces of the holder without applying force to the body. Then tighten the nozzle with force within the following torque ranges. As a guideline, it is equivalent to 2 to 3 additional turns with a tool after manual tightening.
1. Confirm the specifications.The products in this catalog are designed to be used in compressed air systems only. If the products are used in an environment where pressure or temperature is out of the specified range, damage and/or malfunction may result. Do not use under such conditions.
Selection
Mounting
Warning
Warning
1. Confirm the model, type and size before installation.Also make sure that there is no scratches, gouges or cracks on the product.
2. Before pipingBefore piping, it should be thoroughly blown out with air (flushing) or washed to remove chips, cutting oil and other debris from inside the pipe.
Piping
Caution
Caution
3. Wrapping of pipe tapeWhen screwing together pipes and fittings, etc., be certain that chips from the pipe threads and sealing material do not get inside the piping. Also, when the pipe tape is used, leave 1.5 to 2 thread ridges exposed at the end of the threads.
Piping
Caution
4. When tightening the threads, secure the nozzle holder of the blow gun by applying a spanner of 22 mm width across flats to the two chamfered surfaces of the holder without applying force to the body. Then tighten the nozzle with torque specified in the table below. As a guideline, it is equivalent to 2 to 3 additional turns using a tool after manual tightening.Be careful that tightening with torque beyond the ranges in the table below may cause damage to the body.
5. Allow extra length when connecting the tube to accommodate changes in tube length due to pressure.
6. Make sure that no twisting, turning or tensile force or moment load is applied to the port or tube. It may cause the fittings to fracture or the tubing to crush, explode or come loose.
7. Do not abrade, entangle or scratch the tubing. It may cause the tubing to crush, explode or come loose.
1. Use clean air.Do not use compressed air which includes chemicals, synthetic oils containing organic solvents, salt or corrosive gases, etc., as it can cause damage or malfunction.
Air Supply
Warning
1. Do not lubricate the product.It may contaminate or damage the target object.
Lubrication
Warning
Series VMGSpecific Product Precautions 1Be sure to read this before handling.
Hook
Back page 4
Air Supply
9. When the blow gun is being used or stored, make sure that no twisting, turning or tensile force or moment load is applied to the port or tube. It may cause the fittings to fracture or the tubing to crush, explode or come loose.
Series VMGSpecific Product Precautions 2Be sure to read this before handling.
1. Install air filters.Install air filters at the upstream side of blow gun. The filtration de-gree should be 5 µm or finer.
2. Install an after-cooler, air dryer or water separator, etc.Air excessive drainage may cause malfunction of blow gun and contaminate or damage the target object. To prevent this, install an after-cooler, air dryer or water separator, etc.
Caution
1. Do not use in an atmosphere of corrosive gases, chemicals, sea water, water or water vapor or in an environment where such substances may adhere.
2. Provide shading in an environment where the product is exposed to the sunlight.
3. Do not use in an environment where a heat source is at a close distance.
4. Do not use in an environment where static electricity is a problem. It may cause malfunction or failure of the system. Consult with SMC for use in such an environment.
5. Do not use in an environment where spatters are generated. There is danger of fires caused by spattering. Contact SMC for use in such an environment.
6. Do not use in an environment where the product is exposed to cutting oil, lubricant oil or coolant oil. Contact SMC for use in an environment where the product is exposed to such liquid as cutting oil, lubricant oil or coolant oil.
Operating Environment
Warning
1. In periodical inspections, check the follow-ing items and replace the parts if necessary.a) Scratches, gouges, abrasion, corrosionb) Air leakagec) Twisting, crushing and turning of connected tubesd) Hardening, deterioration and softening of connected tubese) Loosening of the nozzle
2. When removing the product, first stop the pressure supply, exhaust compressed air in the piping and confirm the condition of atmospheric release.
3. Do not disassemble or remodel the body of the product.
Maintenance
Caution
1. To prevent lurching of the nozzle due to air pressure, confirm that the nozzle is not loosened or rattling by pulling it by hand before operation.
2. Be sure to wear safety goggles to protect yourself from splashed substances.
3. Do not direct the tip of the nozzle at the face or other parts of a human body. It may cause danger to personnel.
4. Do not use the product to clean or remove toxic substances or chemicals.
5. Do not drop, step on or hit the product. It may cause damage to the product.
6. Do not use the product to disturb public order or public hygiene.
7. This product is not a toy.8. After blowing, be sure to hang the product
on a hook, etc.If leaving the product in a dusty place, particles will enter the product and may result in a malfunction.
Handling
Warning
Record of changes
Edition B
Edition C
· Related devices Series KK/KKH S coupler, changed to the model change products.· High efficiency nozzle data listed. JR
· Best Pneumatics No.1 (Pages 1889 to 1899) extracted. NS
Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPANPhone: 03-5207-8249 Fax: 03-5298-5362URL http://www.smcworld.com© 2009 SMC Corporation All Rights Reserved
Specifications are subject to change without prior notice and any obligation on the part of the manufacturer.
1st printing GZ printing NS 12200SZ Printed in Japan.D-SZ
This catalog is printed on recycled paper with concern for the global environment.
Safety Instructions Be sure to read “Handling Precautions for SMC Products” (M-E03-3) before using.