Power Solutions forTelecommunications
www.deltapowersolutions.com
Flexible and modular telecom solutions for Europe, Middle East and Africa
2 3
About Delta GroupDelta Group, founded in 1971, is the world’s top provider of power management and thermal management solutions. Facing the issue of climate change, Delta Group pursues the mission “To provide innovative, clean and energy-efficient solutions for a better tomorrow.” As an energy-saving solutions provider, Delta’s business scope covers power electronics, energy management and smart green life.
Delta has sales offices worldwide and manufacturing plants in Taiwan, China, USA, Thailand, Japan, Mexico, India, Brazil and Europe. Committed to environmental protection, Delta
has built environmentally-friendly green buildings around the globe since 2004 for its factories and offices.
Delta Group has received many global awards and noteworthy recognition. In 2011 Delta was named to two of the prestigious Dow Jones Sustainability Indexes: the DJSI World Index and the DJSI Asia/Pacific Index. Delta was also recognized as a SAM Gold Class company in the 2012 Sustainability Yearbook of Sustainable Asset Management (SAM).
Contents
SystemsReady to use systems
Modular
Flexible configurations
Components
Services
Delta strives continuously to provide new, innovative solutions for telecommunications that enable sustainable development. Through our wide partner network, we are able to offer these solutions everywhere in EMEA, even in the most remote locations. The following outlines Delta’s customer promise; our smart solutions boost your business, energy-efficient power solutions reduce carbon footprint and energy costs and Delta aims for long-lasting partnerships.
Systems: Indoor systems 6CellD
Systems: Indoor systems 11CabD Systems: Outdoor systems OutD 13 Solutions: Renewable hybrid 15RenE
Thermal Management 17
Intelligence:System & Site Controller 18
Components: Rectifiers 20
Services 22
Smarter. Greener. Together. Intelligence
4 5
global reach
7000+R&D engineers worldwide
23 R&D labs
16 manufacturing plants
33.4% CAGR since 1971
local strength
Delta EMEA: Assembly, Testing, Service & Logistics center Slovakia
Dubnica nad Vahom, Slovakia
310patents
Delta Group: Fast Facts
Delta Slovakia: plant details
18000m2
production space680local employees
4000 systems monthly
Certifications: ISO 9001ISO 14001CSH OHSAS 18000
1971
2009
2010
2011
2012
US$ Millions0.04 4,846 6,609 7,081 7,101
2013
7,180
All Delta products delivered in the EMEA region are assembled, tested and serviced from our assembly and service center in Slovakia.
Having a local hub within Europe assures full compliance with all European quality requirements, quick assembly, excellent service and shorter delivery times.
At Delta, we commit to quality. We trust our center in Slovakia is an essential asset, which allows us to deliver top quality products and first class service to our customers in the EMEA region.
Credit: p. 3-4 - the graphic features creatives designed by Freepik (www.freepik.com) and Flaticon (www.flaticon.com), licensed under Creative Commons BY 3.0
6 7
The CellD product family is based on DC power systems. They are modular and can be configured with additional components to meet any requirement. CellD systems are the most compact on the market and offer extremely high power density.
CellD units can be installed alongside other equipment, in an existing rack for example. They work seamlessly and at optimal efficiency up to more then 97% with Delta’s EnergE rectifiers and advanced controllers. This configuration ensures reliable system operation, generates savings in OPEX and CO2, and maximizes battery lifetime.
Main features
• Wide DC power range – systems available from 40A up to 600A
• Extremely wide input AC voltage range – for all AC networks in any location (80 … 300 Vac). Also for applications where only a low quality AC grid is available
• Wide operating temperatures (-45 °C… +65 °C)• Modular structure and configuration adjusted to customer
requirements • Highest efficiency – CellD systems use high-efficiency
EnergE rectifiers • 19’’ platform – universal 19” rack mounted modules can be
installed in different 19” structures and cabinets.• Advanced monitoring – state-of-the-art controllers ORION,
PSC 3; 6 alarm relays, modems, WEB Interface, SNMP protocol
• Hot plug modules and components
CellD 95.2% 96.4% 97.2%
40A 2.55kWDPS 850B-48-3
100A5.1kW
DPS 850B-48-6
8.7kW DPS 2900B-48-3
125A 8.7kWDPS 2900B-48-3
300A
14.5kW DPS 2900B-48-5 19IN-5U
17.4kW DPS 2900B-48-6 19IN-6U
8.7kW DPS 2900B-48-3 21IN-4U
17.4kW DPS 2900B-48-6 21IN-5U
600A
34.8kW DPS 2900B-48-12 19IN-
9U
20kW DPS 4000B-48-5
19IN-7U
Efficiency
Inst
alle
d po
wer
Applications
• Wireless applications, network base stations, applications, broadband services
• Transmission• Modular UPS configurations• Indoor and outdoor containers • Telecom, wireless, datacom• Containers/shelters
Efficiency is 95.0~95.9% Efficiency is 96.0~96.9%Efficiency is 97.0~97.9%
Pantone 2665 C
Indoor systems: CellD Technical Specifications CellD 40 CellD 100 CellD 125
General DPS 850B-48-3 DPS 850B-48-6 DPS 2900B-48-3 DPS 2900B-48-3
Rectifier module DPR 850B-48 (max. 3 pcs.) DPR 850B-48 (max. 6 pcs.) DPR 2900B-48 (max. 3 pcs.) DPR 2900B-48 (max. 3 pcs.)
Efficiency 95.2% 95.2% 96.4% or 97,2% 96.2% or 97,2%
Install power (max. config.)
2.55 kW 5.1 kW 8.7 kW 8.7 kW
Input protection (recom.)
25 A gL/gG fuse 3 x 10 A (3L+N+PE) 3 x 20 A (3L+N+PE) 3 x 20 A (3L+N+PE)
Dimensions H x W x D 43.6 (1U) x 444 (19’) x 280 mm 86.8 (2U) x 444 (19’) x 295 mm 86.8 (2U) x 444 (19’) x 323 mm 133.5 (3U) x 481.5 (19’) x 329 mm
Weight 4.1 kg 7.0 kg 7.0 kg 15 kg
AC input
AC configuration L+N+PE 3L+N+PE 3L+N+PE 3L+N+PE or 3x (L+N+PE) or L+N+PE
Input voltage range 80 - 300 VRMS 80 - 300 VRMS 80 - 300 VRMS 80 - 300 VRMS
Frequency range 45 – 66 Hz 45 – 66 Hz 45 – 66 Hz 45 – 66 Hz
Mains connection Screw terminals Screw terminals Screw terminals Screw terminals
DC output
Max. output current / max. installed power
40 A / 2.55 kW 100 A / 5.1 kW 100 A / 8.7 kW 125 A / 8.7 kW
Load breakers 6x(2-30 A) or 2 x (6-50A) 12 x (2-30 A) or 4 x (6-50A) 12 x (2-30 A) or 4 x (6-50A) 11 x MCB (2 – 63 A)
Battery breakers 2 x MHCB 50 A 2 x 100 A 2 x 100 A 2x MCB (80 – 125 A)
LVD (battery) Yes Yes Yes Yes
PLD (not critical loads) No Optional Optional Optional
Output protection Inbuilt fuses (both poles)Over-heating protection
Critical / non critical loads configuration
N/A 6 / 6 or 2 / 2 6 / 6 or 2 / 2 5 / 6
Control / monitoring
Controller ORION; PSC 3
Local interface Display, keypad, LEDs
Remote monitoring Alarm relays, modem option, LAN, SNMP protocol
Others
Operating temperature -45 - +65 °C -45 - +65 °C -45 - +65 °C -45 - +65 °C
Humidity (relative) 95% max, non cond. 95% max, non cond. 95% max, non cond. 95% max, non cond.
Environment standard ETSI EN 300 019-1-3 ETSI EN 300 019-1-3 ETSI EN 300 019-1-3 ETSI EN 300 019-1-3
Safety standard IEC 60950 IEC 60950 IEC 60950 IEC 60950
EMC standard EN 300 386 EN 300 386 EN 300 386 EN 300 386
Ordering
System 3799321900 3799361100 3799361100 3791605600
Rectifier TPS1010004B-PML-M TPS1010004B-PML-M ESR-48/56B F-S or ESR-48/56D A-M
ESR-48/56B F-S or ESR-48/56D A-M
8 9
CellD Technical SpecificationsCellD 300
General DPS 2900B-48-5 19IN-5U DPS 2900B-48-6 19IN-6U DPS 2900B-48-3 21IN-4U DPS 2900B-48-6 21IN-5U
Rectifier module DPR 2900B-48 (max. 5 pcs.) DPR 2900B-48 (max. 6 pcs.) DPR 2900B-48 (max. 3 pcs.) DPR 2900B-48 (max. 6 pcs.)
Efficiency 96.4% or 97,2% 96.4% or 97,2% 96.4% or 97,2% 96.4% or 97,2%
Install power (max. config.)
14.5 kW 17.4 kW 8.7 kW2 17.4 kW
Input protection (recom.)
3 x 40 A (3L+N+PE) 3 x 40 A (3L+N+PE) 3 x 20 A (3L+N+PE) 3 x 40 A (3L+N+PE)
Dimensions H x W x D 222 (5U) x 444 (19’) x 315 mm 266 (6U) x 444 (19’) x 315 mm 177 (4U) x 495 (21’) x 315 mm 222 (5U) x 495 (21’) x 315 mm
Weight
AC input
AC configuration 3L+N+PE configurable 3L+N+PE configurable 3L+N+PE configurable 3L+N+PE configurable
Input voltage range 80 - 300 VRMS 80 - 300 VRMS 80 - 300 VRMS 80 - 300 VRMS
Frequency range 45 – 66 Hz 45 – 66 Hz 45 – 66 Hz 45 – 66 Hz
Mains connection Screw terminals Screw terminals Screw terminals Screw terminals
DC output
Max. output current / max. installed power
250 A / 14,5 kW 250 A / 17.4 kW 250 A / 8.7 kW 250 A / 17.4 kW
Load breakers 15-21 x MCB (2-63 A) 15-21 x MCB (2-63 A) 18-24 x MCB (2-63 A) 18-24 x MCB (2-63 A)
Optionally narrow load breakers (13 mm) 21 x MCB (2-63 A) 25 x MCB (2-63 A) 25 x MCB (2-63 A)
Battery breakers 2 x MHCB 50 A 2 x 100 A 2 x 100 A 2x MCB (80 – 125 A)
LVD (battery) Yes Yes Yes Yes
PLD (not critical loads) Optional Optional Optional Optional
Output protection Inbuilt fuses (both poles)Over-temperature protection
Critical / non critical loads configuration
7/8 or 10/8 or 13/8 7/8 or 10/8 or 13/8 7/11 or 10/11 or 13/11 7/11 or 10/11 or 13/11
Control / monitoring
Controller ORION; PSC 3
Local interface Display, keypad, LEDs
Remote monitoring Alarm relays, modem option, LAN, SNMP protocol
Others
Operating temperature -45 - +65 °C -45 - +65 °C -45 - +65 °C -45 - +65 °C
Humidity (relative) 95% max, non cond. 95% max, non cond. 95% max, non cond. 95% max, non cond.
Environment standard ETSI EN 300 019-1-3 ETSI EN 300 019-1-3 ETSI EN 300 019-1-3 ETSI EN 300 019-1-3
Safety standard IEC 60950 IEC 60950 IEC 60950 IEC 60950
EMC standard EN 300 386 EN 300 386 EN 300 386 EN 300 386
Ordering
System 3799294100 3799294100 3799294100 3799294100
Rectifier ESR-48/56B F-S or ESR-48/56D A-M
ESR-48/56B F-S or ESR-48/56D A-M
ESR-48/56B F-S or ESR-48/56D A-M
ESR-48/56B F-S or ESR-48/56D A-M
CellD 600
General DPS 2900B-48-12 19IN-9U DPS 4000B-48-5 19IN-7U
Rectifier module DPR 2900B-48 (max. 12 pcs.) DPR 4000B-48 (max. 5 pcs.)
Efficiency 96.4% or 97,2% 95.2%
Install power (max. config.)
34.8 kW 20 kW
Input protection (recom.)
2 x (3 x 40 A) 3 x 50 A
Dimensions H x W x D
399 (9U) x 480 (19’) x 375 mm 311 (7U) x 480 (19’) x 465 mm
Weight 30 kg 25 kg
AC input
AC configuration 3L+N+PE configurable 3L+N+PE configurable
Input voltage range 80 - 300 VRMS 80 - 300 VRMS
Frequency range 45 – 66 Hz 45 – 66 Hz
Mains connection Screw terminals Screw terminals
DC output
Max. output current / max. installed power
600 A / 34.8 kW 600 A / 20 kW
Load breakers 14x MCB (up to 63 A)
Battery breakers 9x MHCB (up to 100A) or 4x MHCB (up to 200A) or 3x MHCB (up to 300A)
LVD (battery) Yes Yes
PLD (not critical loads)
Optional Optional
Output protection Inbuilt fuses (both poles)Over-temperature protection
Critical / non critical loads configuration
6/8 6/8
Control / monitoring 6/8 6/8
Controller ORION; PSC 3
Local interface Display, keypad, LEDs
Remote monitoring Alarm relays, modem option, LAN, SNMP protocol
Others
Operating temperature
-45 - +45 °C -45 - +45 °C
Humidity (relative) 95 % max, non cond. 95 % max, non cond.
Environment standard
ETSI EN 300 019-1-3 ETSI EN 300 019-1-3
Safety standard IEC 60950 IEC 60950
EMC standard EN 300 386 EN 300 386
Ordering
System 3791546100 3791546100
Rectifier ESR-48/56B F-S or ESR-48/56D A-M TPS1010016C
CellD Technical Specifications
10 11
Site Support cabinets
General SC600 SC770 SC1300 SC1800 SC2000
Internal space 12 U 15 U 27 U 38 U 42 U
Height 620 mm 759 mm 1295 mm 1790 mm 1961 mm
Width 600 mm
Depth 450 or 600 mm
Cooling Natural convention (no fans, no air filter)
Optional equipment Battery shelves (240 kg), 19’ or 21’ internal rails / supporters Front door or battery section covers, Rear panel or steel crossing Blanking plates (1U, 2U and 3U)
Ordering 3799295400 Configurator
Wall Box
General WB 5U WB 8U WB 12U
Internal space 5 U / 19‘ 8 U / 19‘ 12 U / 19‘
Height 253 mm 387 mm 564 mm
Width 548 mm
Depth 475 mm
Cooling Natural convention (no fans, no air filter)
Optional equipment Front door, Blanking plates (1U, 2U and 3U)
Ordering 3791518600 Configurator
AC Panel DC Panel
General APD 19IN-3U DPD 19IN-3U
Optional equipment Screw terminals, Main switch, Circuit breakers (MCB, RCD), Service sockets, Overvoltage protection (OVP),Relays and contactors
DC Load circuits breakers, max 24x or 27x MCB (up to 63A), Two load groups: A and B with 10-14 x MCB each, PLD contactor 250A ( critical and no critical loads groups)
Operating voltage / Current (max.)
AC: 230 / 400 V (1 or 3 ph) / Related to equipment DC: 20-60 V / 300 A
Internal space 19IN: 24 modules (18 mm), 21IN: 27 modules (18 mm) 19IN: 24 modules (18 mm), 21IN: 27 modules (18 mm)
Dimensions H x W x D
133 (3U) x 480 (19’) x 188 mm or133 (3U) x 530 (21’) x 188
133 (3U) x 480 (19’) x 188 mm or133 (3U) x 530 (21’) x 188
Ordering 3799374500 Configurator
Additional Elements
The Delta CabD product series offer high power-density systems, ideal for space critical indoor applications. CabD systems are built on modular basis and allow flexibility in configuration.
The system includes up to twelve rectifiers, AC and DC connections, battery connection and the Delta ORION controller (more about the ORION controller on p. 18).
Main features
• Scalable power system up to 144 kW per cabinet and max 768 kW parallel
• Truly modular building blocks• Mirroring the system built for top entry or bottom entry for
cabling• High efficiency rectifiers up to 97.2%• Enhanced monitoring and controlling with ORION controller
CabD
Applications
• Central offices• Mobile telephone switching offices• Telecom, wireless, datacom• Data centers• Modular UPS configurations• Indoor and outdoor container
ScalableModularUp to 97.2% efficiency
Indoor systems:
12 13
CabD Systems
General CabD 600 CabD 1500 CabD 3000
Max. output current / max. installed power
600 A / 34.8 kW 1500 A / 144 kW 3000 A / > 144 kW
Rectifier module DPR 6000 (max. 8 pcs.),DPR 4000 (max.12 pcs.)DPR 2900 (max.12 pcs.)
DPR 6000 (max. 12 pcs.),DPR 4000 (max. 18 pcs.),
DPR 6000 ( max 24 pcs.)DPR 4000 (max. 36 pcs.),
Efficiency 95.2% ... 97,2% 95.2 % ... 96,5 % 95.2 % ... 96,5 %
AC configuration 3L+N+PE configurable
Load and battery connection
Configurable – modular design
LVD / PLD Option / Option
Controlling and monitoring
ORION / PSC 3
Operating temperature -5 - +45 °C
Dimensions H x W x D Single cabinet:1800/2000/2200 x 600 x 600 mm
Single or multiticabinets 1800/2000/2200 x 600 x 600/800 mm
Single or multiticabinets 1800/2000/2200 x 600 x 600/800 mm
Weight Depends on the configuration
Ordering 3799363900 Configurator 3791691700 Configurator 3791691700 Configurator
CabD Technical Specifications
Delta OutD are cost-effective and high-density outdoor systems, suitable for any climate. The OutD systems are equipped with advanced cooling solutions and ensure remarkable savings in both capital and operational expenditures. Additionally, all OutD products ensure low noise levels and a multi lock mechanism.
We offer a choice between a basic cost-effective configuration and an optimized modular system alternative.
Main features
• Modular• Flexible configuration• Multiple thermal management options• Enhanced noise management• Choice between cost effective or fully optimized
configuration
OutD
Applications
• Network base stations• Wireless applications• Fixed line applications, data communications
Choice between cost effective or fully optimised modular configurations
Outdoor systems:
M series, passive cooling M series, active cooling V series, passive cooling V series, active coolingDC distribution (examples)
Batt. connectionsNH00, NH2, NH3, EFEN 630A, MCB,
TPS2(1200/1600A)
Rectifier shelves
AC input
14 15
OutD Systems
General OutD M Series OutD V Series
Optimized modular design Basic and cost effective solution
Key advantages Flexible and modular
Battery box extension (battery cooler)
IP20 equipment extension
Side by side connection available
-7dB(A) (lower than standard cabinets with the same cooling capacity)
Cost effective
Battery cooler (Separated battery compartment with advanced thermal insulation 40mm EPS and active cooling (TEC or AC))
Single or Multilayer wall design
-7dB(A) (lower than standard cabinets with the same cooling capacity)
Steel or aluminium outside walls
Flexible configuration - 19’ or 21’ racks, battery shelves, multiple PSU options (power supply systems), multiple cable management options
Multiple colling options (AV, AC, Hybrid AC+AC)
Dimensions OutD 1.8M - H1827 x W770 x D852 mm - 35HUOutD 2.0M - H2050 x W870 x D952mm - 40HU
OutD 1.8V - H1860 x W708 x D768mm - 35HUOutD 2.0V – H2060 x W808 x D860mm - 39HU
Protection class up to IP55
Material Steel or Aluminum, Single or multilayer with optional thermal isolation
Lifetime Steel : up to 15 year, Aluminium: up to 20 years
Cooling options AV (Air Ventilation), HEX (Heat Exchanger,) AC (Air con), Hybrid AV+AC (Hybrid cooling Air Ventilation + Air con)
Features Low audible noise emissions (-7dB)Assembling – disassembling on site, Flat packing
Side by side and vertical extension modules Rear door available, side panels removable
Basic solution for high runner applicationsLow audible noise emissions (-7dB)
Options Cable Management: Delta universal, PG, Multigate, Roxtec, Service LED light, Smoke detectors, Flood water sensor, Blocked filter sensors , High humidity sensor, Notebook shelf , Battery movable tray, Heaters, Alarm terminals (Krone, Screw) and much
more
OutD Technical Specifications
The RenE product series are renewable-hybrid energy solutions that provide the network transmission site with power from renewable solar and/or wind energy sources.
RenE secures reliable and uninterrupted power supply even in remote and rural areas with missing power network or low network reliability. In combination with careful energy management from alternative sources, the system lowers operational expenditure, minimizes the waste of energy and can significantly drop CO2 emissions.
All RenE systems can include a selected combination of Orion PLC, Grid/Genset input, rectifiers, solar chargers, DC-converters, AC-inverters, power distribution unit for solar and wind power, load and battery connections, as well as optional automatic transfer switch (ATS). The systems are expandable with battery cabinets and racks with variable cooling options.
RenE
• Power up to 12/24 kW, high power density
• Renewable green energy by wind and solar power
• Cyclic battery discharge for genset fuel efficiency
• ORION controller for ultimate energy management and site control
Main Features Applications• Wireless applications, network base stations
• Remote areas with difficult site access
• Areas with unreliable mains grid or off-grid
Efficiency is 95.0~95.9% Efficiency is 96.0~96.9%Efficiency is 97.0~97.9%
Pantone 2665 C
Solutions: Renewable hybrid
Reliable “green” powerLow OPEXUp to 97.2% efficiency
16 17
RenE-InD-300-48 RenE-InD-600-48 RenE-OutD-300-48 RenE-OutD-600-48
Input grid section
AC connection 3L + N + PE
Nominal voltage 3 x 230 VRMS (L-N)
Voltage range 88 - 300 VRMS
Frequency range 45 - 66 Hz
Current nominal / phase 25 ARMS 50 ARMS 25 ARMS 50 ARMS
Mains terminal Terminal blocks, or main breaker
Input protection, transient OVP
Optional
Input generator section
AC connection 3L + N + PE
Nominal voltage 3 x 230 VRMS (L-N)
Current nominal / phase 25 ARMS 50 ARMS 25 ARMS 50 ARMS
Automatic transfer switch Voltage relay monitoring, mechanical interlocking (optional)
Mains terminal Terminal blocks, or main breaker
Input protection Optional
Input renewable power section
Renewable DC connection
6 feeds 10A 12 feeds 10A 6 feeds 10A 12 feeds 10A
Voltage range 70-350 Vdc
Current max / pole 10 ADC
Input terminal 6x2P Switch 12x2P Switch 6x2P Switch 12x2P Switch
Input protection Internal fuse
Transient protection 600Vdc/2+V
Output power section
Rectifier power 12 kW max 24 kW max 12 kW max 24 kW max
Solar power 6 x 2,2 kWpeak 12 x 2,2 kWpeak 6 x 2,2 kWpeak 12 x 2,2 kWpeak
Voltage range 42 - 58 Vdc; 53.5 Vdc nom
Battery MCB, MCB See CellD 300 specifications See CellD 600 specifications See CellD 300 specifications See CellD 600 specifications
LVLD 250 600A 250A 600A
PLD 250A, optional 250A, optional 250A, optional 250A, optional
Batt-capacity expansion cabinet
n*600 Ah n*600 Ah n*600 Ah n*600 Ah
Energy management section
Energy management Configurable, depending on applied energy sources and OPEX saving targets
Thermal management Optional Optional Fans and filters Fans and filters
AC & genset mgt Automatic, configurable
Energy meter AC and DC power throughput
General
Ambient temperature -5 - +45 °C -40 - +45 °C
Safety IEC/EN 60950
EMC EN 300 386
Protection IP20, ETS 300 019 Part 1-3 IP55, ETS 300 019 Part 1-4
Ordering 3799279100 Configurator
Active coolingDone via either AC or DC powered air conditioning system, the active cooling solutions are perfect for regions with significant temperature amplitudes. This solution guarantees optimal temperatures at all times.
Passive coolingExcellent solution for mild climates, both OPEX and CAPEX friendly. Delta’s passive cooling solutions are designed with meticulous precision and deliver outstanding results.
Hybrid coolingThe hybrid cooling systems allow intelligent temperature management. This cooling solution meets the challenges of high amplitude temperatures while decreasing OPEX.
Thermal Management
Active cooling Passive coolinga)
Passive coolingb) Hybrid cooling
AirCon 230Vac supply
AirCon 48Vdc supply Air Ventilation Air to Air
HEXThermo-Siphon
HEXAirCon + Air Ventilation
Cooling Capacity 850 – 2000 W@ L35/L35
800 – 2000 W @ L35/L35 100 ~ 250 W/K 80 ~ 160 W/K 100 ~ 600 W/K AV – 250 W/KAC –
2000 W
Power Consumption High High Very low Medium Medium Low
Coefficient of Performance (COP) 1,7~2,0 @ 35/35 1,6~4,0 @ 35/35 10 ~ 26
@ DT=5K2.5. ~ 4.5@ DT=5K
4,0 ~ 5,5@ DT=5K
AV – 26; AC – 1,7 @ L35L35, DT=5K230Vac
supply
Energy consumption OPEX
Investment CAPEX
Active cooling Passive coolinga)
Passive coolingb)
Hybrid cooling
Hea
t Ex
chan
ger
Air F
ilter
Fans Fans
Air C
on
Air F
ilter
RenE Technical Specifications
18 19
ORION
General
Voltage range 18 - 75 Vdc
Current 0.8 ADC (max)
Input protection / switch Internal fuse 2A / none
Dimensions (H x W x D) 40.0 x 83.4 x 175 mm
Weight 0.6 kg
Standards• Safety• EMC
EN 60950, class I; UL 60950; CAN / CSA - C22.2EN 55022, class B; ETSI EN 300386 compliant
Cooling Natural air flow
Operating temperature 0 to +65 ºC
Relative humidity 95%, non-condensing
Functions
System • PLC functionality for customizing and supervision and control of auxiliary devices• AC measurement (internal / external)• Mains failure / phase failure detection and alarming• LVD and PLD functions• Advanced genset functions for fuel savings• Configurable event and data log
Battery • Temperature compensated float charge / Boost and equalize charge• Charging current limitation (advanced)• Low voltage disconnection, state of charge supervision and display• Backup time supervision / life time prediction, automatic capacity test• Symmetry supervision for voltage and currents• Block voltage supervision (optional)
Rectifiers • Individual rectifier information and control• Sequential start-up / system soft start• Efficiency mode with advanced rectifier cycling• Redundancy and power capacity supervision
Features
Rectifier interface Digital, CAN-based
Number of rectifiers Up to 128
Digital input From 4 up to 227
Relay output From 6 up to 99
Temperature From 2 up to 98
Voltage, current Up to 200
Display 1 integrated, up to 2 user interface modules
Local monitoring LAN / WEB browser
Remote monitoring LAN / modem, GSM, GPRS / WEB browser/SNMP/Modbus
Remote alarming Dry contacts / SNMP/SMS
Languages English + 2 downloadable
User interface
Local user interface 5 configurable LEDs; LCD display; Keypad
UIM (optional) 5 configurable LEDs; LCD display; Keypad; Buzzer
Web Four different access levels; more than 200 dynamic web pages; SW and setup updates locally and remotely
SNMP Remote alarms using traps; Dial-out feature together with modems
ORION Technical Specifications
Main Features Applications• Remote monitoring with modem or LAN (Ethernet)
connection• Integrated, user friendly web-server for browser access, and
local HW display and keypad• Integrated PLC (Programmable Logic Controller) functions
to enhance modular flexibility• Monitoring and controlling site infrastructure• PSU control, temperature detector, humidity detector, Grid/
Genset management, battery management, performance data, thermal control, access control, flood detector, smoke/fire detector, intrusion detector, etc.
• Advanced battery management, supervision and testing methods
• Easy maintenance by pluggable architecture
• Network base transceiver stations• Wireless network applications• Fixed line network applications, data communications• Hybrid Power Plants and sites
ORION is a single full site controller solution for any size system, supporting up to 128 rectifiers. ORION is easily expandable with CAN bus communication and a range of front-end modules.
ORION provides full site control, allowing management of all power system features. Monitoring reports and alarms are available via the specifically designed iPhone application, LAN, SNMP or Modbul. Battery management with capacity test and life length prediction as well as enhanced rectifier functions, including redundancy supervision, allow planning site visits in a cost-effective manner.
ORION is hot-pluggable, with easy configuration management and supports various languages. All common battery profiles are pre-configured. The controller supports both lead acid and lithium ion batteries.
System and Site controller Full site controllerRemote monitoring: iPhone App, LAN, SNMP, Modbus Integrates hybrid energy
Intelligence:
Performancedata
Temperaturedetector
Humiditydetector
Gensetmanagement
Batterymanagement
Flooddetector
Smokedetector
Intrusiondetector
AC smartmetering
Remote management
Renewable energy sources
20 21
DPR 850-48 DPR 2900-48 DPR 2900-48 DPR 4000-48 DPR 6000-48
Pantone 2665 C Pantone 2665 C
Output
Nominal system voltage
53.5 V 54.0 V 54.0 V 53.5 V 53.5 V
Operating voltage range
42 - 58 V 40 - 58 V 42 - 58 V 42 - 58 V 42 - 58 V
Power output 850 W 2900 W 2900 W 4000 W 6000 W
Efficiency 95.2% 96.4% 97.2% 95.2% 96.5%
Current limitation 17.7 A 56.25 A 56.25 A 83.3 A 125.0 A
Input
Mains voltage 80 – 300VAC 80 – 310VAC 90 – 300VAC 80 – 300VAC 250 - 530 VAC (3ph)
Mains frequency 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz
Protection Internal fuse 2 x8A (L,N) Internal fuse 20A Internal fuse 20A Internal fuse 2 x 30A Internal fuse 3 x 20A
General
Power density 30 W / in3 36.5 W / in3 36.5 W / in3 27.3 W / in3 26.5 W / in3
Control and monitoring ORION, PSC 3
Hot-pluggable Yes Yes Yes Yes Yes
Dimensions (W x H x D) 51.8 x 40.0 x 247.2 mm 125.5 x 41.0 x 269.9 mm 125.5 x 41.0 x 269.9 mm 82.0 x 86.9 x 377.9 mm 129.5 x 83.0 x 380.7 mm
Weight 0.6 kg 2.0 kg 2.0 kg 3.5 kg 5.2 kg
Cooling Fan cooled with speed control
Acoustics
Operating temperature -40 to + 75 °C -40 to + 75 °C -40 to + 75 °C -45 to + 75 °C -40 to + 70 °C
Standards
Safety EN / IEC 60950; UL 60950; CAN / CSA – C22.2
EMI (radiated) EN 55022 class B
Environment RoHS compliant
Ordering
Order numbers TPS1010004A-PML-M ESR-48/56B F-A ESR-48/56D A-M TPS1010016C
Rectifiers Technical Specifications
With energy efficiency of over 96%, Delta’s EnergE rectifiers are the new benchmark in power density.
EnergE series rectifiers are designed for medium to high power applications and serve for up to 7% lower site energy consumption, delivering significant OPEX savings. Additional benefits are the lower temperature management requirements and lower CO2 emissions.
Delta’s rectifiers are hot-pluggable and can be installed on any system.
Rectifiers
Efficiency is 95.0~95.9% Efficiency is 96.0~96.9%Efficiency is 97.0~97.9%
Pantone 2665 C
Main Features • Market leaders in power density - an essential feature in electronic
devices as it defines the product’s energy conversion capability in relation to its size
• Small size – Delta EnergE rectifiers require less cabinet space than competing products
• Advanced over voltage protection - fewer maintenance trips to the site
• High operation temperatures - EnergE rectifiers also tolerate high operating temperatures, which delivers additional savings. For example, a temperature increase from 40 °C to 50 °C at the site creates savings of over 6%
Applications
• Network base stations• Wireless applications• Fixed line applications, data communications
95.2% 96.4% 96.5% 97.2%
850WDPR 850-48
2900WDPR 2900-48 DPR 2900-48
4000WDPR 4000-48
6000WDPR 6000-48
Efficiency
Pow
er o
utpu
t
Components:
22
EngineeringDuring our extensive experience in the telecom power field, at Delta we have learned that some client needs can be truly unique. Such circumstances require special solutions and we are there to provide them. Our team of highly qualified engineers is available to work with these clients and develop specially engineered solutions to match their unique challenges based on our standard product portfolio, standardization efforts and building block philosophy.
Installation & CommissioningInstallation and commissioning can be a long and costly process, demanding a lot of recourses, time, and most of all - manpower. This is why we are glad to offer you our installation and commissioning services. Our people are well trained and have excellent knowledge of the equipment. They will make sure that your network runs smoothly and within the set timeframes.
MaintenanceWe offer maintenance services for all our products. Our experienced technicians are well trained and have the knowledge needed to deliver seamless maintenance and assure uninterrupted working processes using as well remote monitoring tools providing the advantages of speed and flexibility.
Hot lineFor our clients’ convenience, we provide a customer service hot line, customized to their real needs. This can cover the standard office hours as well as a full 24h service line day by day to ensure highest customer satisfaction.
ConsultingAt Delta we don’t just provide power electronics, we work to solve our customers’ challenges. Our team is always prepared to work together with the customer in order to find the best solution for their situation, providing real network expertise. Our subject matter experts possess the knowledge and experience to understand our clients’ challenges and to provide valuable consult and advice.
TrainingDelta’s engineers are available to facilitate training programs and refreshers, tailored to the client’s specific needs. We will develop the content so that it serves our clients’ individual needs and solves their specific challenges.
Services
www.deltapowersolutions.com
Czech RepublicPerucka 2482/7 120 00 Praha 2, Czech RepublicTel: +420 272 019 330
DubaiGate 7, 3rd Floor, Hamarain Centre,Dubai, United Arab Emirates
FinlandJuvan teollisuuskatu 15, 02921 Espoo, FinlandTel: +358 9 849 660
FranceZI du bois Chaland 2 15 rue des Pyrénées, Lisses 91056 Evry Cedex, FranceTel: +33 1 69 77 82 60
GermanyCoesterweg 45, D 59494 Soest, GermanyTel: +49 2921 987 0
ItalyPiazza Grazioli 18 00186 Roma, ItalyTel: +39 06 69941209
Poland23 Poleczki Str. 02 822 Warsaw, PolandTel: +48 22 335 26 00
RussiaVereyskaya Plaza II, office 401 Vereyskaya str.17 121357 Moscow, RussiaTel: +7 495 644 3240
Slovakia - assembly, testing & logistics center EMEAPriemyselna ulica 4600/1, 018 41 Dubnica nad Vahom, SlovakiaTel: +421 42 466 1111
South AfricaUnit 305B Lougardia Building Centurion, Pretoria, South Arica
SpainCalle Luis I n° 60, Nave 1a P.I. de Vallecas 28031 Madrid, SpainTel: + 34 91 223 74 20
SwedenP.O. Box 3096 SE 350 33 Växjö, SwedenTel: +46 470 706 800
SwitzerlandFreiburgstrasse 251, 3018 Bern Bümpliz, SwitzerlandTel: +41 31 998 53 11
TurkeySerifali Mevkii Barboros Bulvari Soylesi Sok No 19 Y.Dudullu-Umraniye/Istanbul, Turkey Tel: +90 216 499 9910
United KingdomGreenside Way, Middleton, Manchester, M24 1XX, United KingdomTel: +44 161 947 3300
Delta EMEA Headquarters
NetherlandsZandsteen 15, 2132 MZ Hoofddorp, The Netherlandsemail: [email protected]: +31 20 655 0900
Delta Telecom Power - EMEA Locations
© 2014 Delta Electronics, Inc, All Rights Reserved