40
LA1-KN11 KN20 KN02
LA1-KN22 KN31 KN13 KN40 KN04
LC1-K0610 K0910
LC2-K0601 K0901LP2-K0601 K0901
CJX2-K (LC1-K) SERIES AC CONTACTOR
Y-1 Standard power ratingsof 3-phase motors50/60Hz jin category AC-3220V 380V 660V230V 400V 415V 440V 500V 690V
Rated operatingcurrentAC-3 AC-1up to 40440V
Rated non-
conductive
Voltage
Instantaneousauxiliarycontacts
reference.
for motor control, from 6 to 9A(AC-3)for the control of distribution circuits, from 20A(AC-1)
KW KW KW KW KW KW A A V
1 - LC1-K0610- 1 LC1-K0601
1.5 2.2 2.2 3 3 3 6 20 690
- LC1-K0910- 1 LC1-K0901
2.2 4 4 4 4 4 9 20 690 1
1 - LC2-K0610- 1 LC2-K0601
1.5 2.2 2.2 3 3 3 6 20 690
- LC2-K0910- 1 LC2-K0901
2.2 4 4 4 4 4 9 20 690 1
Control circuit: a. c.
Control circuit: a. c.
Reversing contactors for motor control
1 - LP1-K0610- 1 LP1-K0601
1.5 2.2 2.2 3 3 3 6 20 690
- LP1-K0910- 1 LP1-K0901
2.2 4 4 4 4 4 9 20 690 1
Control circuit: d. c.
1 - LP2-K0610- 1 LP2-K0601
1.5 2.2 2.2 3 3 3 6 20 690
- LP2-K0910- 1 LP2-K0901
2.2 4 4 4 4 4 9 20 690 1
Control circuit: d. c.
Composition
Reversing contactors for motor control
Numbero f
contacts
Control circuit: a. c.4 - LA2-KN40
3 1 LA2-KN31
2 2 LA2-KN22
4
Control circuit: d. c.4 - LA3-KN40
3 1 LA3-KN31
2 2 LA3-KN22
4
K range auxiliary contact blocks1 1 LA1-KN11
2 - LA1-KN20
- 2 LA1-KN02
2 2 LA1-KN22
3 1 LA1-KN31
1 3 LA1-KN13
4 - LA1-KN40
4
- 4 LA1-KN04
~~~~~
~~~~~
~~~~~
2
reference
Control circuit:d.c.
θ≤ ℃
41
CJX2-D (LC1-D) SERIES AC CONTACTORS
LC1-EC03LC1-EC09LC1-EE03LC1-EE09
LC1-D09LC1-D12LC1-D18
LC1-D25LC1-D32
LC1-D40LC1-D50LC1-D65
LC1-D40LC1-D50LC1-D65
LC1-D80LC1-D95
Standard power ratings
of 3-phase motors
50/60Hz in category AC-3
220V 380V 660V
230V 400V 415V 440V 500V 690V
Rated operating
current
AC-3 AC-1
up to 40
440V
Rated non-
conductive
Voltage
Instantaneous
auxiliary
contacts
Basic reference.
Complete
with code
indicating control
circuit voltage(2)
Fixing(1)
for motor control, from 6 to 630A(AC-3)
for the control of distribution circuits, from 16 to 1000A(AC-1)
Control circuit:d.c.
For LC1-EC to 32: clip-on mounting onto 35mm rail AM1-DP;for LC1 to 910:clip-on mounting onto 75 rail AM-1DL; for LC1-F:screw fixing.Power terminals:09 to 95, protected against direct finger contact and ready-to-wire terminals
KW KW KW KW KW KW A A V
1 - LC1-EC03*
- 1 LC1-EC09*
- LC1-EE03*
- 1 LC1-EE09*
1 - LC1-D0910
- 1 LC1-D0901
1 - LC1-D1210
- 1 LC1-D1201
1 - LC1-D1810
- 1 LC1-D1801
1 - LC1-D2510
- 1 LC1-D2501
1 - LC1-D3210
- 1 LC1-D3201
1 1 LC1-D4011
1 1 LC1-D5011
1 1 LC1-D6511
1 1 LC1-D8011
1 1 LC1-D9511
1.5 2.2 2.2 3 3 3 6 16 690
2.2 4 4 4 4 4 9 16 690
2.2 4 4 4 4 4 9 25 690
3 5.5 5.5 5.5 5.5 5.5 12 25 690
4 7.5 9 9 10 10 18 32 690
5.5 11 11 11 15 15 25 40 690
7.5 15 15 15 18.5 18.5 32 50 690
11 18.5 22 22 22 30 40 60 690
15 22 25 30 30 33 50 80 690
18.5 30 37 37 37 37 65 80 690
22 37 45 45 55 45 81 125 690
25 37 45 45 55 45 95 125 690
1
θ≤ ℃
42
LC1-D series AC Contactor is suitable for using in the circuits up to the rated voltage 660VAC 50Hz or 60Hz, rated current up to 95A, for making, breaking, frequently starting &controlling the AC motor. Combined with the auxiliary contact block, timer delay & ma-chine-interlocking device etc, it becomes the delay contactor, mechanical interlockingcontactor, star-delta starter. With the thermal relay, it is combined into the electromag-netic starter. The Contactor is produced according to IEC947-2, VDE0660 & BS5452.
CJX2(LC1-D) SERIES AC CONTACTOR
LC1-D170
LC1-D09 with cover
Specifications
Type
Rated workingcurrent(A)
AC3 capacity of phase3 squirrel-cage motor
AC3(KW)
Electrical life
Mechanical life
number of the contact
AC3
AC4
220/230V
380/400V
415V
440V
500V
660/690V
AC-4(1X104)
AC-3(1X104)
3P+NC+NO
Type
Rated workingcurrent(A)
AC3 capacity of phase3 squirrel-cage motor
AC3(KW)
Rated heat current(A)
Electrical life
Mechanical life
number of the contact
AC-3
AC-4
220/230V
380/400V
415V
440V
500V
660/690V
AC-4(1X104)AC-3(1X104)
3P+NO
3P+NC
Volts(VAC)
24 42 48 110 230 240 400 415 440 500 660220/230 380/400
50Hz
60Hz
50/60Hz
B5
B6
B7
D5
D6
D7
E5
E6
E7
F5
F6
F7
P5
-
P7
U5
U6
U7
V5
-
V7
N5
-
N7
R5
R6
R7
S5
-
-
Y5
-
-
M5
M6
M7
Q5
Q6
Q7
LC1-D150
LC1-D115
115
50
30
55
59
59
75
80
10
60
200
600
LC1-D115
50
20
15
22
25
30
30
33
15
80
80
800
LC1-D50
65
25
18.5
30
37
37
37
37
15
80
80
800
LC1-D65
80
32
22
37
45
45
55
45
10
60
125
600
LC1-D80
95
45
25
45
45
45
55
45
10
60
125
600
LC1-D95
150
65
37
75
80
80
90
100
10
60
200
600
LC1-D150
40
16
11
18.5
22
22
22
30
15
80
60
800
LC1-D40
32
13
7.5
15
15
15
18.5
18.5
15
80
50
800
LC1-D32
9
4
2.2
4
4
4
5.5
5.5
20
100
25
1000
LC1-D09
12
5
3
5.5
5.5
5.5
7.5
7.5
20
100
25
1000
LC1-D12
18
7
4
7.5
9
9
10
10
20
100
32
1000
LC1-D18
25
10
5.5
11
11
11
15
15
20
100
40
1000
LC1-D25
AC-3(1X104)
Rated heat current(A)
AC-3(1X104)
43
LC1-DN SERIES AC CONTACTORThe series contactor is suitable for using in the circuit up to voltage 660V AC,75KW,alter,continue power 75KW,400V AC-3,circuit can be used to alter.
Controlled power
LC1-DN09
LC1-DN32
LC1-DN40
LC1-DN80
Accessories:Bloques de contactors auxiliaries y modulow aditivos:ver las paginas 1/52 a 1/59.
Corriente alterna
LC1-D09...D150(bobinas D115Y D150 con supresor de transitorion de fabrica).50/60 Hz
LC1-D09...D150
50 Hz
60 Hz
Corriente continua
Voltios
LC1-D09...D38(bobinas con supresor de transitorio de fabrica)
U de 0.7...1.25Uc
LC1-D40...D95
U de 0.85...1.1Uc
LC1-D115y D150(bobinas con supresor de transitorio de fabrica)
U de 0.75...1.2UcBajo consumo
LC1-D09...D38(bobinas con supresor de transitorio de fabrica)
U de 0.85...1.2Uc
U de 0.7...1.25Uc
Paraotras tensiones de 12 a 690V,ver las paginas 1/68a 1/75
Voltios
24
B7
B5
2412
BDJD
B6
CD ED ND SD FD GD MD UD RD
36 48 60 72 110 125 220 250 440
E7
E5
E6
F7
F5
F6
FE7
FE5
-
P7
P5
-
V7
V5
-
R7
S5
R6
-
S5
-
110 115 230 400 440 50048
BDJD CD ED ND SD FD GD MD UD RD
BWJW CW EW - SW FW - NW - -
BD- - ED ND SD FD GD ND UD RD
245 48 72
BLAL EL SL
Voltios
---
(1)Tensiones del circuito de mando existentes (plazo de entrega variable,consultarnos).
KW KW KW KW KW KW KW A230V220V
400V380V
415V 440V 500V 690V660V
1.000V
Articlecontactorblock440V
contactor
2.2
3
4
5.5
7.5
9
11
15
18.5
22
25
30
4
5.5
7.5
11
15
18.5
18.5
22
30
37
45
55
4
5.5
9
11
15
18.5
22
25
37
45
45
59
4
5.5
9
11
15
18.5
22
30
37
45
45
59
5.5
7.5
10
15
18.5
18.5
22
30
37
55
55
75
5.5
7.5
10
15
18.5
18.5
30
33
37
45
45
80
-
-
-
-
-
-
22
30
37
45
45
75
9
12
18
25
32
38
40
50
65
80
95
115
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
40 75 80 80 90 100 90 150 1 1
LC1-DN9
LC1-DN12
LC1-DN18
LC1-DN25
LC1-DN32
LC1-DN38
LC1-DN40
LC1-DN50
LC1-DN65
LC1-DN95
LC1-DN115
LC1-DN150
LC1-DN80
B7
B7
B7
B7
B7
B7
B7
B7
B7
B7
B7
B7
P7
P7
P7
P7
P7
P7
P7
P7
P7
P7
P7
P7
BD
BD
BD
BD
BD
BD
BD
BD
BD
BD
BD
BD
B7 P7 BD
BL
BL
BL
BL
BL
BL
-
-
-
-
-
-
-
44
LC1-F5004
CJX2-F(LC1-F) AC CONTACTORS
LC1-F115
LC1-F225
LC1-F330
LC1-F500
LC1-F630
Application:LC1-F Series A.C. contactors thereafter referred to contactors are applied for electric
power circuits of 50 or 60Hz,voltage up to 1000V and current to 780A,They are used for
remotely making and breaking circuits and frequently actuating and controlling A.C.
motors.They can be assembled with blocks such as auxiliary contact block,air time
delay head and Y-stars.Also they can be directly plugged in by thermal relays and
constructed as magnetic starters.
4 pole AC contactorAC1 200-1000AAC3 115-630AAC/DC circuit
Fuse (SCPD)Three phase motor rated
power
AC3 380V 50HZ
Weight
Kg
Appointedthermalcurrent
AC1lth/A
Rated work
current
380VAC3le/A
No.ofAuxiliarycontact
NOKW
Ratedcurrent
In/AHp-chModel
Model
LC1
5.42751854 90 425125 RT16-3
4.3 2001154 55 25075 RT16-2
4.52501504 75 355100 RT16-2
5.73152254 110 500150 RT16-3
8.53502654 132 630180 RT16-3
4 330 400 160 220 RT16-4 800 10
4
4
4
400
500
630
500
700
1000
200
250
335
280
335
450
RT16-4
RT16-4
RT16
800
1000
1250
10
12.9
20.5
F1854
F1154
F1504
F2254
F2654
F3304
F4004
F5004
F6304
Rated standard power of 3-phasemotors 50/60Hz AC-3
Rated operatingcurrent(A)
Instantaneousauxiliarycontacts
Basic referenceComplete with code
indicating controlcircuit voltageAC-3 up
to 440VAC-1
40
KW
30
40
55
63
75
100
110
147
200
200
KW
30
40
55
63
75
100
110
147
200
200
KW
30
40
55
63
75
100
110
147
200
200
KW
30
40
55
63
75
100
110
147
200
200
KW
30
40
55
63
75
100
110
147
200
200
KW
30
40
55
63
75
100
110
147
200
200
220V230V
380V400V 415V 440V 500V
660V690V
A A
115 200
150 250
185 275
225 315
265 350
330 400
400 500
500 700
780
1000630
16000
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Fixing
LC1-F115..
LC1-F150..
LC1-F185..
LC1-F225..
LC1-F265..
LC1-F330..
LC1-F400..
LC1-F500..
LC1-F630..
LC1-F780..
θ≤ ℃
45
CJX2-Z (LP1-D) DC CONTACTORS
LP1-EC03LP1-EC09LP1-EE03LP1-EE09
LP1-D09LP1-D12LP1-D18
LP1-D25LP1-D32
LP1-D40LP1-D50LP1-D65LP1-D80LP1-D95
Standard power ratings
‘of 3-phase motors
50/60Hz in category AC-3
220V 380V 660V
203V 400V 415V 440V 500V 690V
Rated operating
current
AC-3 AC-1
up to 40
440V
Rocted non-
conductive
Voltage
Instantaneous
auxliary
contacts
Basic reference.
Complete with
code
indicating control
circuit voltage(2)
Fixing(1)
for motor control, from 6 to 630A(AC-3)for thecontrol of distribution circuits, from 16 to 125A(AC-1)
Control circuit:d.c.
For:clip-on mounting onto. For 40 to 80:clip mounting onto 75mm rail AM1-DL.For:srew fixing.
Power teminals:protected against direct contact and ready-to wire terminals.
1.5 2.2 2.2 3 3 3 6 16 690
KW KW KW KW KW KW A A V
1 - LP1-EC03
- 1 LP1-EC09
1 - LP1-EE03
- 1 LP1-EE09
1 - LP1-D0910
- 1 LP1-D0901
1 - LP1-D1210
- 1 LP1-D1201
1 - LP1-D1810
- 1 LP1-D1801
1 - LP1-D2510
- 1 LP1-D2501
1 - LP1-D3210
- - LP1-D3201
1 1 LP1-D4011
1 1 LP1-D5011
1 1 LP1-D6511
2.2 4 4 4 5.5 5.5 9 16 690
2.2 4 4 4 4 4 9 25 690
3 5.5 5.5 5.5 7.5 7.5 12 25 690
4 7.5 9 9 10 10 18 32 690
5.5 11 11 11 15 15 25 40 690
7.5 15 15 15 18.5 18.5 32 50 690
11 18.5 22 22 22 30 40 60 690
15 22 25 30 30 33 50 80 690
18.5 30 37 37 37 37 65 80 690
22 37 45 45 45 45 80 125 6901 1 LP1-D8011
25 45 45 45 55 45 95 125 6901 1 LP1-D9511
θ≤ ℃
46
CJX2-N (LC2-D) SERIES REVERSING CONTACTOR
Accessories(supplied separately)
(1)Fit with mechanical interlock electrical interlocking.
(2)CJX2-ec to 32:clip-on mounting onto 75mm rail or screw fixing.
Standard power ratings
‘of 3-phase motors
50/60Hz in category AC-3
220V 380V 660V
203V 400V 415V 440V 500V 690V
Rated operating
current
AC-3
up to
440V
Max.
rated
operating
Voltage
No.ofinstantaneousauxiliarycontactsper concator
Contactors suppliedwith coil Basicreference. completewith code indicatingcontrol circuitvoltage(2)Fixing-Connection(3)
1.5 2.2 2.2 3 3 3 6 660
KW KW KW KW KW KW A V
2.2 4 4 4 5.5 5.5 9 660
2.2 4 4 4 4 4 9 660
3 5.5 5.5 5.5 7.5 7.5 12 660
4 7.5 9 9 10 10 18 660
5.5 11 11 11 15 15 25 660
7.5 15 15 15 18.5 18.5 32 660
11 18.5 22 22 22 30 40 660
15 22 25 30 30 33 50 660
18.5 30 37 37 37 37 65 660
22 37 45 45 45 45 80 660
22 45 45 45 45 45 95 660
(horizontally outer)
Pre-wired power connections
Control circuit:a.c.
-
-
-
-
-
-
-
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
LC2-EC09
LC2-EE09
LC2-D1201
LC2-D0901
LC2-D1801
LC2-D2501
LC2-D3201
LC2-D4011
LC2-D5011
LC2-D6511
LC2-D8011
LC2-D9511
LC2-EC03LC2-EC09LC2-EE03LC2-EE09
LC2-D09LC2-D12LC2-D18
47
STAR-DELTA STARTERS
Motor manufactures generally specify machine load torques. Example:Maximum resistivetorque on completion of star-delta starter(expressed as a proportion of the rated torque).(1)Protection must be provided by the addition of an overload relay. to be ordered separately,Select group rate overload relay for setting at 0.58 of the rated motor current.(2)Standard control circuit voltages LC1-D40(LX1-D6)
Standard power ratingsof squirrel cage motorsMains voltage-delta co-nnection220V 380V 415V 440V
for motor control
Without overlotad relay(1)Without isolatorAssembled by
This method of starting is only applicable to 3-phase motors whose delta connection corre-sponds to the main voltage and on which all 6 starter terminals are accessibe.Star-delta starting should be used for motor starting on no-loador having a low load torque andgradual build-up:-The starting current in star connection is about 1.8 to 2.6 the rated current.The transition fromstar to delta connection must occur when the machine has run up to speed, A too rapid buid-upin load torque would cause the tabili set run-up speed to be too low and would thereforeeliminate any advantage in this method of starting:this is the case with certain machineswhose load torque depends on its speed(a characteristic of centrifugal machines, for example).All star-delta starters are now supplied with a special LA2-DT2 time delay relay which imposesa delay of 40ms 15 on the Star-delta contactor during the transition period in order to allow thetar contactor efficient breaking time.
Auxiliary contacts availableon each contactorLine Deita StarKM2 KM3 KM1
Star-deltanechanicalinterlock
Basic referenceComptete with codeindicaing controlcircuit voltageSee pageopposite(2)
Plated lmounted
Maximum oper ating rated:30/sta4rts/hour.Maximm starting time:30 seconds.
4 7.5 7.5 7.5 - - - - - 1
5.5 11 11 11 - - - - - 1
11 18.5 22 22 - - - - - 1
15 25 30 30 - - - - - 1
18.5 37 37 37 - 1 1 - - 1
30 55 59 59 - 1 1 - - 1
37 75 75 75 - 1 1 - - 1
45 80 80 80 - 1 1 - - 1
Star-delta starting
Specification:Pre-wired power and control circuit connections.
Without LC3-D09
Without LC3-D12
Without LC3-D18
Without LC3-D32
Without LC3-D40
Without LC3-D50
Without LC3-D80
Without LC3-D95
QJX2-12(LC3-D12)
QJX2-50(LC3-D50)
starting in direct delta con-nectionstarting in star connectionmachine resistive
1
2
3
48
AUXILIARY CONTACT BLOCKS
(1)Including 1N/O and 1N/C make befofe break contacts.
(2)Device fitted with 4 terminals For earth screen continuity.
(3)With extended scale from 0.1 to 0.6s
(4)With setting time of 40ms 15ms between opening of the N/C contact.
For contactor LC1-D
Instantaneous auxiliary contact blocks.
For use in normal operating environments
Composition ReferenceNumber Max.numeber of blocks per contactor
of Clip-on mounting
contacts front Side
- - 1 1
- - 2 -
- - - 2
- - 2 2
- - 1 3
- - 4 -
- - - 4
- - 3 -
2 -
- 2
1 1
LA1-DN11
LA1-DN20
LA1-DN02
LA1-DN22
LA1-DN13
LA1-DN40
LA1-DN04
LA1-DN31
LA1-EN20
LA1-EN02
LA1-EN11
Time delay anxiliary contact blocks
1 block per contactor Screw lamp
Number Max.number of blocks per contactor
of Clip-on mounting
contacts Front Side
Time delay
Type
Reference Range
1N/O 2
+
1N/C
ON-
delay
0.1 to 3s(3) LA2-DT00.1 to 20s LA2-DT20.1 to 180s LA2-DT40.1 to 3s(3) LA3-DR00.1 to 30s LA3-DR20.1 to 180s LA3-DR4
LA1-DN11
LA1-DN22
LA1-DT2
F8-11
×
49
CONTACTOR REPLACEMENT COILS
LX1-D09
LX1-D40
LX4-D09
LX4-D65
Standard control circuit voltages
Volts 12 24 36 42 48 110 127 220 230 240 380 400 415 440 500
50Hz J5 B5 C5 D5 E5 F5 G5 M5 P5 U5 Q5 V5 N5 R5 S5
60Hz - B6 - D6 E6 F6 - M6 - U6 Q6 - - R6 -
50/60Hz - B7 - D7 E7 F7 - M7 - U7 Q7 V7 N7 R7 -
Standard control circuit voltages
Volts
U0.8 1.1UC
U0.7 1.25UC
Replacement coils unit reference
12
JD
JW
24
BD
BW
36
CD
CW
48
ED
EW
60
ND
-
72
SD
SW
110
FD
-
125
GD
-
220
MD
MW
250
UD
-
440
RD
-
For LC1-EC,EE, CA2-EN LX1-EC
For LC1-D09,12,18, CA2-DN LX1-09
For LC1-D25,32 LX1-25
For LC1-D40,50,65,80,95 LX1-40
For LP1-EC,EE, CA2-EN2 LX4-EC
For LP1-D09,12,18, CA3-DN LX4-09
For LP1-D25,32 LX4-25
For LP1-D40,50,65 LX4-40
For LP1-D80,95 LX4-80
For LC1-F115,F150 LX4-F115
For LC1-F185,F225 LX4-F185
For LC1-F265,F330 LX4-F265
For LC1-F400 LX4-F400
For LC1-F500 LX4-F500
For LC1-F630 LX4-F630
660
Y5
-
-
600
YD
-
~
~
50
JRS1 (LR2-D) SERIES THERMAL OVERLOAD RELAYS
Standard IEC 947-4 specifies a tripping time for 7.2 times the setting current IR:Class 10: between 2 and 10 seconds.Class 20: between 6 and 20 seconds.
Note:Select and set the overload relay according to the full load current value on the motormanufacturer’s rating plate.
For motor protection
Compensated and differential
with anual or automatic reset and trip indication
a.c or d.c operation
Thermal overload relays to be used with fuses
Relay
setting
range
Fuses to be used
with selected relay
Type
am gi-gL
For direct
mounting beneath
contactor
LC1
Reference
A A A
Class 10A
0.10 0.16 0.25 2 09¡«¡«¡«¡«¡«32 LR2-D13010.16 0.25 0.5 2 09¡«¡«¡«¡«¡«32 LR2-D13020.25 0.4 1 2 09¡«¡«¡«¡«¡«32 LR2-D13030.40 0.63 1 2 09¡«¡«¡«¡«¡«32 LR2-D13040.63 0.1 2 4 09¡«¡«¡«¡«¡«32 LR2-D13050.1 1.6 2 4 09¡«¡«¡«¡«¡«32 LR2-D13061.25 2 4 6 09¡«¡«¡«¡«¡«32 LR2-D13X61.6 2.5 4 6 09¡«¡«¡«¡«¡«32 LR2-D13072.5 4 6 10 09¡«¡«¡«¡«¡«32 LR2-D13084 6 8 16 09¡«¡«¡«¡«¡«32 LR2-D13105.5 8 12 20 09¡«¡«¡«¡«¡«32 LR2-D13127 10 12 20 09¡«¡«¡«¡«¡«32 LR2-D13149 13 16 25 09¡«¡«¡«¡«¡«32 LR2-D131612 18 20 35 09¡«¡«¡«¡«¡«32 LR2-D132123 32 40 63 25,32 LR2-D132228 36 40 80 32 LR2-D235317 25 25 50 40¡«¡«¡«¡«¡«95 LR2-D235523 32 40 63 40¡«¡«¡«¡«¡«95 LR2-D335330 40 40 100 40¡«¡«¡«¡«¡«95 LR2-D335537 50 63 100 50¡«¡«¡«¡«¡«95 LR2-D335748 65 63 100 50¡«¡«¡«¡«¡«95 LR2-D335955 70 80 125 65¡«¡«¡«¡«¡«95 LR2-D336163 80 80 125 80,95 LR2-D336380 93 100 160 95 LR2-D3365
LR2-D1307
LR2-D2353
LR2-D3361
~
~
~
~
~
~~
~
~
~
~~
~
~
~
~
~
~
~
~
~
~
~
~
51
IP55
ENCLOSED D.O.L. STARTERS
KW KW KW KW KWKW A
Utlisation category AC-3
Standard power ratings
of 3-phase motors 50/60Hz
220V 380V 660V
230V 400V 415V 440V 500V 690V
Rated operating
current
up to
440V
Basic reference.
Complete with
code indicating
control circuit
Voltage(1)
2.2 4 4 4 5.5 5.5 9
3 5.5 5.5 5.5 7.5 7.5 12
4 7.5 9 9 10 10 18
5.5 11 11 11 15 15 25
7.5 15 15 15 18.5 18.5 32
11 18.5 22 22 22 30 40
15 22 25 30 30 33 50
18.5 30 37 37 37 37 65
22 37 45 45 55 45 80
25 45 45 55 55 45 95
Standard control circuit voltages LC1-D(LX1-D)
IP42IP55
IP42IP55
IP42IP55
IP42IP55
IP55
IP55
IP55
IP55
IP55
LE1-D094LE1-D093
LE1-D124LE1-D123
LE1-D188LE1-D185
LE1-D258LE1-D255
LE1-D325
LE1-D405
LE1-D505
LE1-D655
LE1-D805
LE1-D955
Control circut:a.c
Instantaneous
auxiliary
contacts
Basic reference.
Complete with code
indicating control
circuit voltage
Instantaneous Number
o fcontacts
4
4 -
3 1
2 2
CA2-DN40
CA2-DN31
CA2-DN22
Instantaneous Number
o fcontacts
4
4 -
3 1
2 2
CA3-DN40
CA3-DN31
CA3-DN22
LE1-D09LE1-D12LE1-D18
LE1-D25LE1-D32
CA2-DN
CA3-DN