Controlli per terminali apr 07
FANCOILS CONTROLSELECTRONIC BOARD - KCMS CMS - KCMS/PCM CMSPCMNEW WIRED CONTROL PANEL- KPCM
Controlli per terminali apr 07 n.2
FUNCTIONSFUNCTIONS
Controlli per terminali apr 07 n.3
IDROWALLIDROWALLIDROWALLIDROWALL
FRENDFRENDFRENDFREND
UTNBUTNBUTNBUTNB
CONTROLLI
UTNAUTNAUTNAUTNA
YARDYEVYARDYEVYARDYEVYARDYEV
BRIOEVBRIOEVBRIOEVBRIOEV
UTNC-EVUTNC-EVUTNC-EVUTNC-EV
IDROWALL FREND BRIOEV UTNC-EV
CONTROLLI
KPCMKTCMKICM
Controlli per terminali apr 07 n.4
CMS KCMS
CMSPCM KCMS/PCM
STI KSTI MVR KMVRRI-KRI
CONTROLSCONTROLS
KPCM
KTCM
KICM
Controlli per terminali apr 07 n.5
CMSPCM KCMS/PCM
KPCM
n. 46Eunit-systemPrice List
ADVANCED CONTROLS
Controls supplied loose to be mounted in the unit
YardyEV
EuroYardyEVKCMS - Master/slave electronic board
Euro
Euro
Euro
Controls factory fittedYardyEV
EuroYardyEVCMS - Master / slave electronic board
Euro
EuroSTI - Temperature sensor for additional water coil EuroMVR - Module ON/OFF valve Euro
Wired panelYardyEV
Euro
Wall-fitted control panel YardyEV
Euro
Serial interfaces supplied loose for connection with CMS and KCMS YardyEVKISI - Can-bus serial interface
EuroKRS485 - RS485 serial interface
EuroKRS232 - RS485/RS232 serial converter
EuroKUSB - RS485/USB serial converter
Euro
MVP - MVT VERSIONSKCMS/PCM - Master electronic board+ wired control panel (for MVP and MVT)
(E500200330)* E500200331147,00
ALL VERSIONS
(E500200350)* E50020035295,00
KSTI - Temperature sensor for additional water coil for connec tion to KCMS
E50020042015,00
KMVR - Module for ON/OFF valves E50020040043,00
MVP - MVT VERSIONSCMSPCM - Master electronic board + wired control panel (for MVP and MVT)
CMSPCM162,00
ALL VERSIONS
CMS110,00
RI - Infrared receiver RI45,00
STI16,00
MVR47,00
ALL VERSIONSKPCM - Control panel controlled by wire. Wall mounted. (E500200290)* E500200291
52,00
ALL VERSIONS
KICM - Wall-fitted control panel with LCD dispaly to be connected to KCMS.
E968573499
ALL VERSIONSE500200295
60,00
293,00
E968573497293,00
69,00
E96857349475,00
E968573496
CMS KCMS
New codes for electrical board and panel
(E500200330)* E500200331
CONTROLSCONTROLS
* ATTENTION: the codes into brackets are available until may 2007. The close codes (without brackets) will be available afterward, according to Circular Letter
Controlli per terminali apr 07 n.6
New electronic board KCMS CMS
SCR ECO digital input don’t change, SIC EIR change their position New digital input DI5 (not available for Frend and Idrowall) for new function:
OCCUPANCY function (NC) only for KICM panel, (by modifying board parameters (P45=8;P93=3) trough installer password on the KPCM control panel)
Controlli per terminali apr 07 n.7
New electronic board KCMS CMS
New digital output CCH CCA
Controlli per terminali apr 07 n.8
FUNCTIONS SETTING FUNCTIONS
COMFORT FUNCTIONS
Controlli per terminali apr 07 n.9
FUNCTIONS
NOVELTY•Full AUTO: the desired temperature is showed on the display. The unit, according to the room temperature and the setting temperature, sets the working mode (cool/heat).
SETTING FUNCTIONS1. Full auto 2. Cool3. Dry 4. Fan 5. Heat 6. Heat + heater7. Full Auto + heater
KPCMKTCM
KICM
User set temperature
P02=2°C
P03=2°C
P04=0,5°C
P04=0,5°C
mode
room temperature
HEAT
OFF
COOL
Legend
Controlli per terminali apr 07 n.10
FUNCTIONS
ATTENTION•The following functions aren’t available with KICM control panel:
•Orienting/swing - Clock - Timer - Continuous ventilation (by key) – Keybord stop •Probe IN/OUT function is available for:
KICM trough DIP SWITCH (DIP6) setting KPCM trough key on the panel Not used with the remote control KTCM (the probe is always set in the unit)
•The periodic ventilation is always disabled with KPCM and KICM with Probe In function activated (probe into the unit)•Confort control (by modifying board parameters P36=1 trough installer password on the KPCM control panel).
COMFORT FUNCTIONS1. Orienting/swing (on Idrowall)
2. Clock3. Timer4. Sleep5. Hot start6. Too cool7. Memory
11. Economy (ECO)12. Lock function / Blocco remoto (KICM)13. ON/OFF remote control (SCR)14. Summer/Winter remote control (EIR)15. Security control (SIC)16. Occupancy (only KICM) new 17. Probe IN/OUT18. Continuous ventilation19. Alarm20. MASTER/SLAVE21. Periodic ventilation22. Confort control new 23. Blocco tastiera (solo KTCM)
KPCMKTCM
KICM
Controlli per terminali apr 07 n.11
User set temperature
P02=2°C
P03=2°C
P04=0,5°C
P04=0,5°C
mode
room temperature
HEAT
OFF
COOL
Legend
COMFORT CONTROL FUNCTIONComfort control (by parameters)
When the set-point is decided by a system manager (supervision), the Comfort Control function gives the possibility to increase or reduce the Set-point (+-3°C) in the room with the UP-DOWN bottoms.(The function have to be enable modifying board parameters P36=1 trough installer password on the KPCM control panel.)The set value is 22 °C
22°C
Controlli per terminali apr 07 n.12
LOCK FUNCTION FUNCTION
Attention: to obtain the changing set-point ±3°C must be set the Confort Control Function
Controlli per terminali apr 07 n.13
Changes to the DIP-Switches must be made with the board disconnected from the power supply. The DIP-Switches on the electronic board (see right figure) can be changed using a sharp tool. The DIP-
Switches can be changed correctly by following the instructions present on the component and in the following table.
DIP-SWITCHES
Controlli per terminali apr 07 n.15
CCH
Chiller input, chilled water required from the thermostat (NO)
DIGITAL OUTPUT: FUNCTION
CCH –Chiller input
Controlli per terminali apr 07 n.16
CCA
Boiler input, hot water required from the thermostat (NO)
DIGITAL OUTPUT: FUNCTION
CCA – Boiler input