1. Automatic Compression Testing Machine
Automatic Compression Testing Machine with computer interface
Purpose: for testing Mechanical properties of cement and concrete samples
Capacity: Maximum 200KN, MIN: 5KN
Machine Features:
Features of Compression, flexure, prism testing and tensile split testing
Variable pace rate with facilities of changing it during test
Auto close/ release of dump valve
Safety protections features
Operating System:
Window based system along with laser printer for data output
Software features:
The equipment should be operated through menu driven software
Capable of recording peak load and peak stress
Equipped with peak stress calculation
The software should include features like multiple machine control,test method and
result editor with security features
Calibration:
Dynamic cacibration facility for individual mode of compression, flexural, tensile split,
strength and prism testing
Power Supply: through CVT
Installation and Warranty:
Commissioning and installation including any civil and electrical work will be the
responsibility of the equipment supplier. NIFFT will be providing only space and
electricity
1 year comprehensive onsite warranty inclusive of all spares part
3 year maintenance contract after warranty, this should be coated separately
Vendor should provide training
DASH Page 2
2. Laboratory Ball Mill Purpose : For grinding of material
Capacity: Volume should be ~ 40 L, should be able to grind 2 to 5 Kg material in one batch
Machines features
The material of construction should be steel
Suitable motor drive
Rotation counter
Steel balls
40 mm dia, 4 Kg
36 mm dia, 4 Kg
30 mm dia, 4 Kg
25 mm dia, 4 Kg
19 mm dia, 4 Kg
12.5 mm dia, 4 Kg
Accessories
Energy Meter
Sound Proof Enclosure
Installation and Warranty:
Commissioning and installation including any civil and electrical work will be the
responsibility of the equipment supplier. NIFFT will be providing only space and
electricity
1 year comprehensive onsite warranty inclusive of all spares part
3 year maintenance contract after warranty, this should be coated separately
3. Potentiostat/ Galvanostat with Impedance analysis
facilities
1. Purpose: The equipment as a single unit or as a set of interconnected and compatible units
should be capable of the following:
i) Electrochemical Measurements including Cyclic Voltametry, Chronoamperometry,
Chronopotentiometry and Electrochemical Impedance analysis
ii) Corrosion measurements including Tafel, Linear polarization resistance
iii)Capable of measurements in potentiostatic, galvanostatic, potentiodynamic modes
2. Specifications:
Potentiostat/ Potentiodynamic mode operation Applied Voltage Range ±10V Applied Voltage Resolution for ±10mV signal = 500nV
for ±100mV signal = 5µV for ±1V signal = 50µV for ±10V signal = 500µV
Applied Voltage Accuracy ±0.2% of value
DASH Page 3
Maximum Scan Rate At least 10 V/s Minimum Scan Rate 0.1 mV/s or lower Maximum Scan Range ±10V Hold time (at constant potential)
24 hours or more
Galvanostat mode operation Applied Current Range ±2A Applied Current Resolution ±1/10,000 x full scale Applied Current Accuracy ±0.2% of reading, ±0.2% of range
±10pA Hold time (at constant current) 24 hours or more
Impedance (EIS) Measurement Mode Potentiostat/Galvanostatic Frequency Ranges 10µHz to 5MHz Minimum AC Voltage Amplitude 0.1mV RMS Sweep Linear or Logarithmic Current Compliance 10 uHz to 5 MHz Frequency Analysis for the
entire compliance current & voltage range maximum up to 2A & 40V range.
General Features Power Requirements 750VA Max.
Voltage range 100Vac to 250Vac, 50-60Hz Operating Temperature Range 10 - 50 C iR Compensation Positive Feedback Yes Dynamic iR Yes
Computer and software
PC/ Workstation
at least 250 GB HDD, 64 bit processor with
minimum 2.5 GHz processing speed, at least 10
GB RAM with original windows OS (Windows 8.0
or later) and Windows Office
Suitable interface
High speed compatible interface
Softwares Windows compatible softwares for all above
requirements indicated in 1. All operations to be
controlled through softwares and all data
acquisition and analysis should be done through
appropriate software
Software should allow continuation in different
modes (e.g. potentiostatic followed by
potentiodynamic) without interruption.
3. Accessories Required: Corrosion cell made of durable transparent material with a capacity of 1000ml, should
have ports for all electrodes, gas inlet/outlet, Cell should be able to withstand
temperatures up to 60 oC
DASH Page 4
Standard Calomel electrodes - 02 Nos
Ag/AgCl electrodes - 02 Nos.
Platimum Counter electrode - 02 Nos
All technical/ instruction manuals required
UPS 1KeV for power backup 30 minutes
4. Installation & Warranty:
1 year comprehensive on-site warranty inclusive of all parts,
All installation/ commissioning to be carried out at NIFFT
3 year Maintenance Contract after Warranty to be quoted separately
5. Optional:
Electrochemical Noise Analysis capability (Hardware and software)
Additional electrochemical cells
Instrumentation Laboratory
1. CIRCUIT SIMULATION
i) NI MultiSim (Schematic Entry / Simulation)
Support for Hierarchical and Multisheet designs
Support for Spreadsheet view showing details of Nets, components, layers etc Support for forward and backward annotation Support for ERC for schematic
Support for Ideal, Virtual, rated and Animated components Should support Standard SPICE 3X5/XSPICE The software should be able to export the simulation data as *.xml,*.lvm, Mathcad
formats
Support for 3-dimensional breadboarding
Should be able to export the netlist to third party tools like PADS,Orcad, Protel,
PCAD etc.
Spice models to be as a part of the library database Support for Analog/Digital Mix mode simulation
Should be possible to create spice based simulation models Support for creating custom symbols The software should have customizable convergence assistant
Should have a Simulation advisor to provide possible error solutions Should support export/import of NI measurement data files Support for dynamic current and voltage probes to display the current and
voltage at different nodes Should have inbuilt virtual NIELVIS schematic to rig up designs and perform
simulation Support for 3-dimensional breadboarding of NI ELVIS Support for component wizards like OPAMP, Filter, CE Amplifier, 555 timer
Support for free running simulation
DASH Page 5
Should be able to input data/ visualize the simulation data using virtual
instruments like the Oscilloscope, Function Generator, Multimeter, Bode plotter,
Word Generator, 16 Channel logic Analyzer, Network Analyzer, Spectrum
Analyzer, Distortion Analyzer etc.
Should support various analysis for the design like the DC, AC, Transient, Fourier,
Temperature Sweep, Parameter Sweep, Noise, Noise figure, Monte Carlo, Worst
Case, Batched, User defined, Pole- Zero, Transfer, Distortion, Nested Sweep etc Should have support for industry standard virtual instruments like Agilent Osc,
Agilent Function generator, Agilent Multimeter, Textronix Osc.
Should be able to integrate Virtual instruments developed in NI Labview for design analysis and debugging ( ex: signal analyzer, signal generator etc).
Should be possible to import real time data (lvm) as an input source
Support for Intel 8051/8052, Microchip PIC16F84(a) support Should support Assembly and C language for developing the design code
Support for peripherals like RAM/ROM, UART, Keypads, Alpha-numeric LCD etc No restrictions on the number of components or instruments on a worksheet Should support Windows platforms NT/2000/XP
License should be perpetual in nature and standalone Software locked
ii) NI UltiBoard (PCB Layout)
Support for forward/backward annotation
Should be able to Cross probe with the schematic design
Support for Spreadsheet view showing/editing details of Nets, components, layers,
tracks etc Support Push and shove trace placement Support be able to export manufacturing files Gerber, DXF, IPC-D-356A, SVG Support for differential Impedance, Transmission Line calculator
Support different types of Vias – Blind, buried, Microvias Support for 64 layers and 1 nanometer resolution Inbuilt real time DRC Should be possible to create footprint models
Support for Split-power planes Support keep-in/keep-out areas
Support for pin and gate swapping The pcb tool should support Manual, Interactive and Autorouting Support for net shielding on tracks Support for through hole and SMD footprint components
Support for SMD mirroring Support for Copper pour, testpoint insertion Support copy Route & Replica Place
Support for 3D board with the ability to print and export 3D info in 3D IGES, DXF Should support Gridless follow-me placement Should be possible to Load and save technology files Customizable layer viewing
Support for customizable cost factors Should be possible to turn off ratsnest for selected nets for better visualization and probing The software should support selective layer print outs
Support import of gerber files
DASH Page 6
Support for Automatic tear-dropping Should support Windows platforms NT/2000/XP
License should be perpetual in nature and standalone Software locked
iii) PSIM SOFTWARE
(a) Basic: For analysis and design of power converter and control
systems
Applications:
AC/DC Rectifiers Active Filters
Battery Chargers Grid-Link Operations Power Factor Correction Power IC Components and Adjustable Speed Drive Systems
Reactive Power Compensators Single-Phase and Three-Phase Inverter and UPS Systems
Switch mode Power Supplies
(b) Digital Control Module
Zero-order hold Unit delay
Z-domain transfer function blocks Digital FIR and IIR filters Quantization blocks Digital integrator and differentiator controllers
Circular buffers
(c) Motor Drive Module
DC machines 3-phase squirrel-cage and wound-rotor induction machines Permanent-magnet and externally-excited synchronous machines
Brushless DC machines Switched reluctance machines Constant-torque, constant-power, and general-type mechanical load
Speed and torque sensors Gear Boxes
2. DESIGN LAB
i) TECHMO SOFTWARE (3 Phase Induction Motor Design)
TECHMO is powerful and easy tool which provide a simple automated and integrated
invironment to design squirrel cage and wound rotor induction motor
The software is very helpful for finding detailed design parameters which are essential to
design an induction motor
DASH Page 7
Highly interactive graphical user interface makes it easy to understand the overall
constructional details of design motors
Different characteristics plots relate to the design performance of the motor.
Software also have the capability to find out equivalent circuits parameter, temperature rise
and loss factors at different stages of the motor operation.
The estimation of cost relating to different model may be achieved with the help of this
software in details
ii) TECHTRAN SOFTWARE (Single phase and Three Phase Transformer Design)
It is a useful software for the design of single /three phase transformer and the following
are the features of this software.
Design of core, window, air gape of the window, frame and yoke
Primary and secondary winding design parameters
Magnetization Parameters (Magnetizing force, saturation flux density, coercitivity,
retaintivity, permeability, B-H Curve etc ) calculations
Calculation of Hysteresis, eddy current, copper lossesseperately and efficiency of the
transformer
Estimation equivalent circuit parameters
Voltage regulations
Estimation of temperature rise and related cooling system design along with cooling curve
Estimation of cost
iii) LABVIEW SOFTWARE
LabVIEW software is ideal for any measurement or control system and NI design platform.
Integrating all the tools that engineers and scientist need to build a wide range of applications in dramatically less time.
Lab VIEW is a development environment for problem solving, accelerated productivity and continual innovation. The software should be inline with latest version.
3. INSTRUMENTATION
i) ELVIS Board
The NI Educational Laboratory virtual instrumentation suite (NI ELVIS) is a hands-on design and prototyping platform that integrates twelve commonly used instrument such as oscilloscope , DMM function generator and Bode analyser etc into a compact form suitable for the hardware lab for class room. Based on NI LabVIEW graphical system design software, NI ELVIS with USB plug and play capabilities, the integrated system offers the
DASH Page 8
flexibility of virtual instrumentations and also allows for quick, easy measurement acquisition and display. It helps educators to teach a variety of concepts such as measurement and instrumentation, analog and digital circuits, control and mechatronics, telecommunications and embedded theory.
ii) Analog System Lab Kit
Four JFET General Purpose Dual operational amplifiers(TL082)
Three wide bandwidth precision analog multipliers(MPY634) Two 12-bit parallel input multiplying digital-to-analog converters(DAC7821)
Arrays of resistors & capacitors along with potentiometers. Slots for connecting diodes and transistors for building various analog systems. A breadboard for the general purpose prototyping to carry out student mini-projects. The power supply is internally connected to all the ICs (except DAC) to provide ±10V to
ensure proper functioning. The DACs require 5V externally for operation.
iii) Technical Specification of “Atomic Force Microscope (AFM)”
i) “Atomic Force Microscope (AFM)” is required for microstructural characterization of
advanced research on materials. The system should also have the modular
attachments to perform scanning tunnelling microscopy (STM), and non-contact
mode of AFM operation on the samples at ambient condition. The detailed
specifications are given below:
ii) Atomic force imaging mode: Contact mode and non-contact mode of operation.
True quantitative lateral force measurements must be possible. Contact and non-contact
mode resolution: X-Y: 0.05nm, Z: 0.01nm or better.
iii) Scanning tunnelling imaging: Scanning tunnelling mode resolution: X-Y: 0.05nm and
Z: 0.01nm or better.
iv) Sample size: Range 1mm x 1mm x 0.5mm to 10mm x 10mm x 2mm. Sample or
tip movement should be controlled by Computer and CCD camera.
v) Scanning range: Maximum scan area 20µm x 20µm or Larger
vi) Data acquisition system: Windows based data acquisition system (minimum
Windows 7) with PC and printer (colour LaserJet).
vii) Accessories: Scanning tips for atomic force imaging (100 Nos.), Scanning
tunnelling imaging (100 No.) and NC-AFM (100 No.) Rates for each of the tips must
be quoted separately.
viii) CCD camera: Suitable CCD camera should be attached with the system for
positioning of the sample and tips in both the AFM & STM mode of operation.
Magnification of CCD camera should be 100X or better.
ix) Calibration: Standard samples for calibration (AFM & STM) must be provided
DASH Page 9
x) Anti-Vibration Platform: Vendor should requested to supply the suitable anti-
vibrational platform for the system.
xi) Software: Vendor should provide the software for all the modes of operations and
the image processing software’s.
xii) Warranty: Comprehensive warranty for 1 Year after successful installation,
commissioning and Training. Vendor should depute 1 trained person for 1 year to
operate and maintain the system successfully at NIFFT.
xiii) Training: Onsite training after installation at NIFFT, RANCHI
xiv) AMC: Vendor is requested to provide the AMC rates after the completion of
warranty period.
xv) Acceptance criteria: For AFM and NC-AFM atomic resolution imaging on mica
or HOPG
xvi) For STM, atomic resolution imaging on HOPG.
xvii) Technical bid should also mention the preinstallation requirement of the quoted
system. Capability of the vender must be provided with the technical bid by giving
the list of similar equipment, which are already been installed. Proven record for
supply of similar equipment in India and after sale service in India will be criteria for
vendor selection.
Iv) TECHNICAL SPECIFICATION FOR LUMINESCENCE SPECTROMETER
i) Supply, installation and commissioning of Luminescence spectrometer. The instrument must
have following specifications. The scope of supply includes all the accessories needed for
smooth functioning of the instrument.
Principle:
Computer Controlled luminescence spectrometer with the capability of measuring fluorescence,
phosphorescence or chemiluminescence.
Source:
Pulsed xenon flash lamp.
Monochromator:
Excitation 200 – 800 nm or better. Emission: 200-900nm or better. Standard excitation cut-off
filter at 390 nm.
Wavelength Accuracy:
+/- 1.0 nm or better.
Wavelength Reproducibility:
+/- 0.5 nm or better.
Spectral band pass:
The excitation and emission slits should be 2.5-15 nm or better.
Scanning Speed:
Should be user selectable
Emission filters:
Computer selectable cut off filters - 290, 350, 390, 430, and 530 nm, a blank (to act as a shutter),
a 1% attenuator.
DASH Page 10
Sensitivity:
Minimum signal to noise level using the Raman band of water, excitation 350 nm is 500:1 RMS
measuring noise on the Raman peak, and 2000:1 RMS measuring noise on the baseline.
Polarizer:
Instrument must include an automated Polarizer that consists of 2 filter wheels; each wheel
containing a horizontal and vertical polarizing element. Polarizer positions should be software
controlled and can be manually set or automatically controlled for polarization, anisotropy or G-
factor.
Software operating system:
Windows environment. The luminescence intensity and the excitation and the emission
wavelength should be displayed in real time. Spectral and time drive data should be displayed in
real time and can be stored on disk.
Data Analysis:
Routines should be available for performing mathematical calculations on stored data. These
include arithmetic functions, smoothing, 1-4th order derivatives, area, peak, normalization,
merge, difference, interpolate and least squares fit.
Essential Accessories Required to be offered along with the main instrument:
Accessories required for analysis of liquid, powder, thin film, flat and turbid samples.
Computer:
PC required for control and operating the instrument should be quoted along with the
instrument. The computer should have following minimum specifications. Intel Core i5
processor, 1 TB hard disk, 4 GB RAM, DVD RW drive, TFT monitor, colour LaserJet.
Power Supply:
Power supply for the instrument should be 230V, 50 Hz as per Indian Standard
Warranty: One year from date of installation
Installation, Commissioning & Training: The installation, commissioning and training should be done to the satisfaction of user scientist free of cost at NIFFT Ranchi.
Spares and Consumables:
Spares and Consumables required for smooth functioning of equipment for 5 years should be quoted optionally.
v) TECHNICAL SPECIFICATIONS FOR SPECTROSCOPIC ELLIPSOMETER
The instrument should include at least the following specifications
Goniometer
Variable from 450to 900with steps of 50 or less
Spectral Range 450 nm to 1000 nm or better
DASH Page 11
Thickness range: Up to 5 microns or more
Accuracy of measured R.I. 0.01 or better
Accuracy of film thickness ± 0.1 nm or better for 10 nm SiO2 on silicon
Sample alignment: Suitable microscope optics for alignment and
adjustment
Sample stage features X-Y translation over at least 100 x 100 or 100
mm dia
Measurable film parameters Refractive index, extinction coefficient, and
Film Thickness
Capability for accurate measurements of transparent films on transparent substrates.
PC system PC required for control and operating the
instrument should be quoted along with the
instrument. The computer should have
following minimum specifications. Intel Core
i5 processor, 1 TB hard disk, 4 GB RAM, DVD
RW drive, TFT monitor, colour LaserJet
printer.
Software Windows based software with data acquisition
and analysis facilities.
Other Requirements/Features
1. User List: Provide user list with contact (address and Phone) details.
2. One (1) year warranty
3. Spares and Consumables required for smooth functioning of equipment for 5 years should
be quoted optionally.
Installation & training The installation, commissioning and training
should be done to the satisfaction of user
scientist free of cost at NIFFT Ranchi.
vi) UV-Visible spectrophotometer with solid state facility
Computer controlled double beam spectrometer
DASH Page 12
Monochromator: Single or more
Range: 200-900nm (liquid sample), extendable up to 1100 nm or better for solid
samples
1 pair of standard cuvett (3.5ml volume) for liquid sample analysis
Software for calculation in spectrum, photometric and kinetic mode
Photometric range: 0-5Abs
Low noise (0.03% or bellow)
Wavelength accuracy: 0.2nm ; Resolution: 0.1nm
Wavelength reproducibility: + 0.05nm
Validation software for routine standardization
Integrated sphere attachment for solid samples
Barium sulphate standard
Low stray light interference for better analysis (0.006%T or less at 22onm for NaI)
Softer support for conversion calculator using different equation.
Accessories:
1 pair of standard cuvett (3.5ml volume)
Branded PC and Laser Printer
1KVA UPS
Vendor must support the document of proven 10 supply of similar equipment in India
vii) Computer controlled FTIR spectrometer
Range: 7850 to 350cm-1 or higher
Beam splitter: Germanium coated KBr
Easy technique for sample analysis as KBr palate and liquid samples
Light source: ceramic
Detector: DLATGS detector with temperature control
Spectral resolution: 0.25cm-1 or better (mid IR), 2cm-1 or better for NIR
DASH Page 13
Wave number accuracy: +0.01cm-1
Scan speed 20spectra/min or more
Signal to noise ratio: 50000:1 or better
Software for transmittance to absorption conversion.
Standard library to support analysis
3D data presentation
Curve fitting facility for peak separation and quantitative area calculation.
Data recoding with time for kinetic measurements
Accessories:
Dimond ATR for solid, liquid and film samples.
Vendor must support the document of proven 5 supply of similar equipment in India
viii) ELECTRONIC BALANCE
Maximum Capacity – 40 grams
Accuracy – 0.5 mg
TECHNICAL SPECIFICATIONS
1. INSTRUMENT:
High resolution X-ray powder diffractometer with Bragg Brentano geometry, low axial divergence, solid
state detector for the study of qualitative and quantitative phase analysis, determination of crystal
structure, precise lattice parameter determination and crystallite size and lattice strain determination.
Latest generation diffractometer should be provided, which may be upgraded to new future applications
without much realignment. The equipment should serve the purpose of Powder diffraction. Detailed
specifications are as follows.
2. OPTICS: Fast interchangeable pre-aligned optics (both primary and secondary) with pre-aligned
optical devices/modules (X-ray source, monochromator, soller slits, antiscatter slits, filters, detector,
sample stage etc.), plug & play type without requirement of any realignment should be provided.
3. X-RAY GENERATOR: State of the art X-ray generator with output power of 3kW or higher, and
stability better than 0.1 % variation for 10% variation on main voltage
4. SOURCE
4.1 X-ray Tube : long fine focus ceramic X-ray tube with copper anode, minimum 2kW or higher power,
usable for line focus and point focus.
5. FILTER
5.1 Ni Filter for subtraction of Cu K-beta line: One set
DASH Page 14
6. PRE-ALIGNED SECONDARY MONOCHROMATOR: Pre-aligned secondary graphite monochromator to
stripe off fluorescence radiation from iron sample when Cu tube is used as x-ray source.
7. DETECTOR
7.1 One Number of pre-aligned scintillation detector, which does not require realignment on
replacement.
7.2- 2-theta measurement range : from -3degree to +156 degree or wider (smallest increment in 2-
theta should be 0.0001degree or lower )
7.3- Peak Position reproducibility : +/-0.005 degree or better throughout the entire measuring range.
7.4- Peak FWHM for NIST standard of Lanthanum hexaboride : 0.03 degree or less
8- PRE-ALIGNED SAMPLE STAGE :
8.1- Sample stages with suitable holders (for powder and solid flat sample) must be provided. The basic
system must be compatible for future attachments (pre-aligned non-ambient device).
9- PRE-ALIGNED SLIT SYSTEMS (Primary and secondary): The slit systems should be exchangeable with
the.
9.1- Pre-aligned, Exchangeable Soller slit for both primary and secondary: at least three set
9.2- Pre-aligned, Exchangeable Antiscatter slit: One set of at least three sizes
9.3- pre-aligned, Exchangeable divergence slit : One set of at least three sizes
10- DATA ACQUISITION SYSTEM:
10.1- Computer controlled Data acquisition and analysis.
10.2- Application Software :
10.2.1 Licensed Software with CD-ROM back up in English for control of equipment, online data
acquisition, data evaluation, data storage, peak search and matching, phase identification, License at
least for 10 years
10.2.2 Licensed Application software for Rietveld Refinement, sequential pattern stripping, qualitative
and quantitative phase estimation are to be included in the basic system. License at least for 10 years.
10.3- Data base: crystal information of mineral data base for minerals including ICDD PDF4 and ICSD
database (latest release available at the time of despatch of the XRD system) with Crystal Information
File and licence for at least five years for each.
10.4- Computer with desktop monitor and DVD writer for data collection and analysis, virus free
operation during data transfer and colour laser printer.
11- POWER SUPPLY : 230V/ 50 Hz/ single phase
12- Installation and commissioning is to be done at NIFFT site.
DASH Page 15
13- Instruction and Service manuals - One set of instruction and service manual in English is to be
provided.
14- Warranty : Three years Comprehensive Warranty from the date of installation at NIFFT.
15- TRAINING: At installation site
16- SAFETY: Radiation level less than 1mSv/h or in compliance to the safety measure of International
standard.
17. ESSENTIAL CONSUMABLES: Essential spares and accessories for trouble free functioning of the
instrument for three years.
18- ESSENTIAL ACCESSORY:
18.1- Cooling water supply : trouble-free Imported External chiller with rugged performance from
internationally reputed manufacturer should be provided.
19- OPTIONAL ACCESSORY:
19.1- Detector type : (i) One number of Pre-aligned 1D solid state fast detector with strip width/channel
width/pitch/pixel size of 75micron or smaller should be provided. The detector should be guaranteed for
at least 5 years of performance.
19.2- Pre-aligned programmable automatic divergence slit should be provided so as to achieve low
background at a 2-theta lower than 5 degree.
19.3- Pre-aligned programmable automatic antiscatter slit should be provided so as to achieve low
background at a 2-theta lower than 5 degree.
19.4- X-ray tube with Co anode- One No.
19.5- X-ray tube with Cr anode- One No.
20- OTHER ESSENTIAL TERMS & CONDITIONS :
20.1- The manufacturer should have an Indian office or Indian agent
20.2- The supplier and must have supplied equipments in India in the last ten years.
20.3- Certification of Satisfaction for after sales service support from minimum of three users in India.
20.4- Pre-installation requirements of electrical power, instrumental earthing, water, ambient air, civil /
mechanical/fabrication should be included in the quotation.
20.5- The vendor has to provide clear compliance statement with respect to the specifications given in
the tender document and fully supported by the manufacturer’s original literature and part numbers.
Any other claims will not be accepted and may lead to the rejection of the bid.
20.6- Supplier should ensure to provide service, spares and maintenance (on chargeable basis) up to ten
years.