Transcript
Page 1: Determination of AdsorbableOrganic Halogen in Wastewater...Anion Suppressor (Cation Exchanger) HF, HCl, H2SO4in H2O KaF, KCl, K2SO4 in KOH Waste H+ Without Suppression Counter Ions

The world leader in serving science

Jingli Hu, Jeff Rohrer, and Kirk ChassaniolThermo Fisher Scientific, Sunnyvale, CA

Determination of Adsorbable Organic Halogen in Wastewater

Page 2: Determination of AdsorbableOrganic Halogen in Wastewater...Anion Suppressor (Cation Exchanger) HF, HCl, H2SO4in H2O KaF, KCl, K2SO4 in KOH Waste H+ Without Suppression Counter Ions

2

• AOX (Adsorbable Organic Halogen)

• Combustion IC

• Ion Chromatography

• Methods

• Results and Conclusions

Outline

Page 3: Determination of AdsorbableOrganic Halogen in Wastewater...Anion Suppressor (Cation Exchanger) HF, HCl, H2SO4in H2O KaF, KCl, K2SO4 in KOH Waste H+ Without Suppression Counter Ions

3

• Organohalogens are toxic and persistent compounds

• Given high priority in the monitoring and control of environmental pollution

• AOX represents the equivalent amount of fluorine, chlorine, and bromine contained in

organic compounds, expressed as chloride substances that can be adsorbed from

water onto activated carbon

• Organic halogen compounds cannot be directly analyzed by ion chromatography (IC)

• Automated combustion ion chromatography (CIC) is often used to determine these

organic halogen contaminants.

AOX Introduction

Page 4: Determination of AdsorbableOrganic Halogen in Wastewater...Anion Suppressor (Cation Exchanger) HF, HCl, H2SO4in H2O KaF, KCl, K2SO4 in KOH Waste H+ Without Suppression Counter Ions

4

Diagram of a CIC System

Page 5: Determination of AdsorbableOrganic Halogen in Wastewater...Anion Suppressor (Cation Exchanger) HF, HCl, H2SO4in H2O KaF, KCl, K2SO4 in KOH Waste H+ Without Suppression Counter Ions

5

CIC System Components

Ion Chromatography

System

Gas Absorption Unit

Furnace Solid/Liquid Autosampler

In CIC, the samples, including halogen-containing compounds, are first combusted and the resultant gases are released into an absorption solution, which is directly injected into an IC system

Page 6: Determination of AdsorbableOrganic Halogen in Wastewater...Anion Suppressor (Cation Exchanger) HF, HCl, H2SO4in H2O KaF, KCl, K2SO4 in KOH Waste H+ Without Suppression Counter Ions

6

Reagent-free Ion Chromatography (RFIC) System

Page 7: Determination of AdsorbableOrganic Halogen in Wastewater...Anion Suppressor (Cation Exchanger) HF, HCl, H2SO4in H2O KaF, KCl, K2SO4 in KOH Waste H+ Without Suppression Counter Ions

7

Pt anode(H2O 2H+ + ½O2 + 2e–)

14538-04

Cation-exchange connectorKOH Generation Chamber

Vent

Pump

H2O

Pt cathode(2H2O + 2e– 2OH– + H2)

[KOH] Current

Flow rate[ + ]

[–]

KOH + H2 KOH

H2

K+

ElectrolyteReservoir

K+

DegasUnit

Hydroxide Eluent Generation

EluGen KOH Cartridge

CR-ATCAnion Trap

Page 8: Determination of AdsorbableOrganic Halogen in Wastewater...Anion Suppressor (Cation Exchanger) HF, HCl, H2SO4in H2O KaF, KCl, K2SO4 in KOH Waste H+ Without Suppression Counter Ions

811309-02

Eluent (KOH) Sample F-, Cl-, SO42-

AnalyticalColumn

(Anion Exchanger )

AnionSuppressor

(Cation Exchanger)

HF, HCl, H2SO4 in H2O

KaF, KCl, K2SO4in KOH

Waste

H+

Without Suppression

Counter Ions

µS

F-

SO42-

Cl-

F- SO42-

Time

µS

Time

With Suppression

Cl-

K+

The Role of Chemical Suppression (KOH)

Page 9: Determination of AdsorbableOrganic Halogen in Wastewater...Anion Suppressor (Cation Exchanger) HF, HCl, H2SO4in H2O KaF, KCl, K2SO4 in KOH Waste H+ Without Suppression Counter Ions

9

Thermo Scientific Dionex Electrochemically Regenerated Suppressors

Page 10: Determination of AdsorbableOrganic Halogen in Wastewater...Anion Suppressor (Cation Exchanger) HF, HCl, H2SO4in H2O KaF, KCl, K2SO4 in KOH Waste H+ Without Suppression Counter Ions

10

Sample Preparation

• Wastewater samples (50 mL) were absorbed onto granular activated carbon

(GAC) columns

• The column was then washed with 20 mL of sodium nitrate washing solution

(0.01 M) at 2–3 mL/min to displace inorganic chloride ions

• A rod was used to push the carbon from the column into a sample boat

• Samples were analyzed with CIC

Page 11: Determination of AdsorbableOrganic Halogen in Wastewater...Anion Suppressor (Cation Exchanger) HF, HCl, H2SO4in H2O KaF, KCl, K2SO4 in KOH Waste H+ Without Suppression Counter Ions

11

Combustion Conditions

Page 12: Determination of AdsorbableOrganic Halogen in Wastewater...Anion Suppressor (Cation Exchanger) HF, HCl, H2SO4in H2O KaF, KCl, K2SO4 in KOH Waste H+ Without Suppression Counter Ions

12

IC Conditions

Thermo Scientific™ Dionex™ Integrion™ HPIC™ System

Page 13: Determination of AdsorbableOrganic Halogen in Wastewater...Anion Suppressor (Cation Exchanger) HF, HCl, H2SO4in H2O KaF, KCl, K2SO4 in KOH Waste H+ Without Suppression Counter Ions

13

Separation of a Standard Anion Mixture

Page 14: Determination of AdsorbableOrganic Halogen in Wastewater...Anion Suppressor (Cation Exchanger) HF, HCl, H2SO4in H2O KaF, KCl, K2SO4 in KOH Waste H+ Without Suppression Counter Ions

14

Determination of AOX in (A) Wastewater and (B) Spiked Wastewater

Page 15: Determination of AdsorbableOrganic Halogen in Wastewater...Anion Suppressor (Cation Exchanger) HF, HCl, H2SO4in H2O KaF, KCl, K2SO4 in KOH Waste H+ Without Suppression Counter Ions

15

Calibration Data, Retention Time, and Peak Area Precisions (n = 3)

Page 16: Determination of AdsorbableOrganic Halogen in Wastewater...Anion Suppressor (Cation Exchanger) HF, HCl, H2SO4in H2O KaF, KCl, K2SO4 in KOH Waste H+ Without Suppression Counter Ions

16

Recovery of AOX Spiked in DI Water (n=3)

Page 17: Determination of AdsorbableOrganic Halogen in Wastewater...Anion Suppressor (Cation Exchanger) HF, HCl, H2SO4in H2O KaF, KCl, K2SO4 in KOH Waste H+ Without Suppression Counter Ions

17

Recoveries of AOX Spiked in Wastewaters (n = 3)

Page 18: Determination of AdsorbableOrganic Halogen in Wastewater...Anion Suppressor (Cation Exchanger) HF, HCl, H2SO4in H2O KaF, KCl, K2SO4 in KOH Waste H+ Without Suppression Counter Ions

18

• AOX can be precisely and accurately determined in wastewater using combustion

ion chromatography

• Analysis was automated using the Mitsubishi AQF–2100H system in combination

with the Dionex Integrion HPIC system with a Dionex IonPac AS18-4μm column

• Suppressed conductivity detection selectivity detects only anionic species in

aqueous solution from the absorbed combustion gas

• Eluent generation frees the analyst from the need to prepare eluent, eliminates the

handling of strong base, and removes a possible source of error

Conclusions

Page 19: Determination of AdsorbableOrganic Halogen in Wastewater...Anion Suppressor (Cation Exchanger) HF, HCl, H2SO4in H2O KaF, KCl, K2SO4 in KOH Waste H+ Without Suppression Counter Ions

19

Thermo Scientific Application Note 72333: Determination of adsorbable organic halogen in wastewater using a combustion ion chromatography systemhttps://appslab.thermofisher.com

Thermo Scientific AppsLab Library of Analytical Applications

Page 20: Determination of AdsorbableOrganic Halogen in Wastewater...Anion Suppressor (Cation Exchanger) HF, HCl, H2SO4in H2O KaF, KCl, K2SO4 in KOH Waste H+ Without Suppression Counter Ions

20

CIC Application Notes• AN72693: Determination of total fluorine, chlorine, and sulfur in aromatic

hydrocarbons by oxidative pyrolytic combustion followed by ion chromatography• AU72588: Determination of Chlorine, Bromine, and Sulfur in Polyethylene

Materials using Combustion IC with a Carbonate/Bicarbonate Eluent• AN72573: Determination of Halogens in Polymers and Electronics using a

Combustion Ion Chromatography System• AN72349: Determination of Chlorine, Bromine, and Sulfur in Polyethylene

Materials using Combustion Ion Chromatography• AN72333: Determination of Adsorbable Organic Halogen in Wastewater using a

Combustion Ion Chromatography System • AN72268: Determination of Fluoride in Tea using a Combustion Ion

Chromatography System• AN1145: Determination of Halogens in Coal Using Combustion Ion

Chromatography• TN72211: Combustion Ion Chromatography with a Dionex Integrion HPIC System


Recommended