Your Quality, Our AssuranceDissolution Media Degasser
Patented
21 Litre Mobile Media Degasser
Patented
CE
NewQuality by Design
£
£
£
£
£
£
£
£
£
£
£
£
£
£
£
£
£
£
Deaeration, preheating and precise dispensing of dissolution
media
Volumetric dispensing with any accuracy of ± 1 % as per USP and
Ph. Eur. specifications
Mobile unit allows dispensing media in the test vessel within
the dissolution bath
Multifunction single hose for aspiration, dispensing, cleaning,
rinsing and drainage
Ergonomically designed nozzle with embedded dispense
switch for ease of operation
User friendly calibration and validation of media volume
Printout of report of calibration, validation and dispense
cycles
Batch wise dispensing of last 10 batches of media
Special nozzle design allows deaeration of surfactants like Sodium
Lauryl Sulphate (SLS)
Programmable deaeration time and temperature for effective
deaeration of different media
Maintains media under vacuum at desired temperature while
in idle condition
Programmable dispense volumes from 200 ml to 4 L
Dispensing rate 900 ml/min
Alphanumeric key pad
Facilitates storage of 20 methods
In-built DO meter for detection of pre-dearation and post-
dearation DO values
Printout of test report via
Automatic rinsing and cleaning cycle and also easy access for
manual cleaning
in-built thermal printer and 80 C
column
Versatility
£
£
£
Unparalleled versatility due to 1 ml volume change
increments0360 turning radius allows
Multifunction single hose ensures no lifting of heavy media tank
maneuvering in tight places
User Friendly
Reports
£
£
Ergonomically designed nozzle with embedded dispense
switch for ease of operation
User friendly validation and calibration of media volumes
£ Print out of validation, calibration, dispensed volume and
temperature reports
2
QbD
EMD-21PDO
With Integrated DO Probe
Temperature Accuracy
+
-o0.5 C
Rugged-SS Construction
Batch Capacity
L21
Memory
10 Reports
No Lifting ofMedia Tank
Dearates Surfactants
Programmable Vacuum
Dead Volume
Virtually
o
Volume Change Increment
1ml
DO Level
<4ppm
Storage
20 ProductsMethods
3
USP 35 states “Dissolved gases can cause bubbles to form, which may change the results of the test.”
< 6 ppm is recommended dissolved oxygen level for USP Prednisone Tablets RS (Ref : USP Dissolution Toolkit version 2.0)
Inter & Intra Laboratory
VariabilityReliabilityRef : Eaton J et al. Perturbation Study of Dissolution Apparatus Variables - A Designof Experiment Approach. Dissolution Technologies; 14(2):20-26.
52.3 % of mean percent dissolved 11.8 % of standard deviation
Effective deaeration reduces variability in results by:
st
1Media Preparator with integrated DO probe
ELECTROLAB
Media Preparator Main Cycle Report
Report with individual vessel DO values
*Data on file (DO: Dissolved Oxygen)
Single batch deaeration reduces process time and ensures inter-vessel consistency in DO level
+
+
Time
Required
Degas Ready to dispense
Degas Ready to dispense
o37 C
o37.5 C o37 C
=For
21 LWater
(1 Batch)
12 mins
13 mins
24 mins
o37.5 C
1 min
25 mins
Aspirate + Heat
Pre-deaeration DO level > 8.5 ppm
Post-deaeration DO level < 4 ppm
Aspirate + Heat
Time
Required
For
8 LWater
(1 Batch)
* =1 min
Features of Optical DO probe
£
£
£
£
£
£
£
£
£
Compliance with ASTM International Method D 888 – 05
Quick response optical sensor technology
No membrane: Cost-effective optical sensor technology
allows maintenance - free operation
No electrolyte, no drift
No O consumption: Precise in low O concentration2 2
No cross sensitivity with pH 1-14, CO , H S, SO2 2 2
Real time temperature compensation
Provides reliable and reproducible results
Rugged and robust stainless steel construction
DO Meter
Part no - 0701A00007
*
• Complete range of Dissolution Testers • Disintegration Testers • Friability Testers • Tablet Hardness Testers• Electromagnetic Sieve Shakers • Tap Density Tester • Bulk Density Tester • Powder Flow Tester • Leak Tester • Peristaltic Pumps
Our Products
The information contained in this document is believed to be correct but ELECTROLAB accepts no liability for any errors and reserves the right to alter specifications without noticeDecember, 2015 / 070F002
CE
ISO 9001ISO 9001 : 2008 CERTIFIED
SCES 047
WISSS
ELECTROLABSales
&Service
Worldwide
ELECTROLAB (India) PVT. LTD.
Head Office : 401, Tirupati Udyog, I. B. Patel road, Off. Western Express highway, Goregaon (East), Mumbai - 400 063, India.
Tel : +91 - 22 - 4041 3131 • E-mail : [email protected]
Factory : EL 23/24, T. T. C., Electronic Zone, M. I. D. C, Mahape, Navi Mumbai - 400 710, India.
Tel : +91 - 22 - 4161 3131 • Website : www.electrolabindia.com
(CIN NO : U33110MH2002PTC136735)
EMD-21PDO
Accuracy
Media volume
Flow rate (during run cycle)
Dispense volume
Temperature range
Accuracy
Flow rate (during run cycle)
Temperature accuracy
Piston pump accuracy
Degassing level (measured by DO meter)
Media tank
Vacuum
Piston pump
Electrical power
Dimensions (Ø x H)
Weight
* Dependent on media type and conditions
Model
Product code
Temperature :
Aspiration :
Dispense :
Other specifications :
S.S. : 0730100
110 Volts
2 L to 21 L
± 1 %
900 ml/min
S.S. : 0740100
230 Volts
50 ml to 4 L
± 1 %
900 ml/min
0 0 20 C to 50 C00.5 C
100 kg
Stainless Steel
100 mm/Hg to 500 mm/Hg
High performance piston pump
230 VAC/50 Hz 10 %110 VAC/50 Hz ± 10 %
±
55 x 92 cm cm
± 1 %
< 4 ppm of *DO
Specifications