1
Safecom's proven patented SYNERGY-2 , DPSV4, Power Booster & Dual T-former P.S turns existing CATV networks into a super power synergy platform that provide most reliable and economic powering system for unlimited backup time.
Safecom Smart Grid Patented technology providing complete set of unlimited backup Power for CATV networks & Without Batteries
DPS v4Power Booster 4G
SYNERGY-2
Tel +972-544311933 / Fax +972-9-7968033 / Habustan st (PO 132) / Israe l 40691/ E-mai l [email protected]
Dual T-former 2X 15A 60,66,72,87 V +
DOCSIS Monitoring
2
Based on the strategic placing of intelligent power management devices throughout the network, in the event of a power outage the SYNERGY-2 & DPS4 draws power from the distant available source over existing coax or power cables. Utilizing breakthrough direct AC/AC On-Line stabilize technology safecom's SYNERGY-2 and Power Booster ensures an optimal voltage level – even over long distances.
The Backup Power concept .
Tel +972-544311933 / Fax +972-9-7968033 / Habustan st (PO 132) / Israe l 40691/ E-mai l [email protected]
3 Tel +972-544311933 / Fax +972-9-7968033 / Habustan st (PO 132) / Israe l 40691/ E-mai l [email protected]
Based on the strategic placing of intelligent power management devices throughout the network, in the event of a power outage the DPSv4 draws power from the nearest available source over existing coax or power cables. Safecom's proven smart grid technologies greatly improve network powering reliability while creating significant savings on both capital and operational expenses.
1 2
3 4Power +
Signal
To remote / Node / Amplifier
Optical Node/Trunk
amp
P.S
21
34
AC 1 input .AC 2 input
Local output to local Optical Node.(AC+RF) Backup IN.OUT (AC+RF to remote Node/ amp)
DPS V4US PATENT 5747888 EP 0708559
4 Tel +972-544311933 / Fax +972-9-7968033 / Habustan st (PO 132) / Israel 40691/ E-mail [email protected]
MINIMIZE THE NUMBER OF POWER SUPPLIES IN THE NETWORK. INCREASING THE POWERING AREA COVERED BY POWER SUPPLY
Vin 30-87Vac (US)Vin 30-64Vac (EU)
tv
tv
Vout 87 Vac (US) Vout 60 Vac (EU)
US PATENT 8,415,822
POWER BOOSTER US PATENT 8,415,822
Utilizing patented breakthrough direct on-line zero crossing AC/AC stabilize technology safecom's ensures an optimal voltage level to Optical Nodes & Line Amplifiers even the source of power from over long distances. Passive , Standalone element , power booster solves the power distribution problem in a CATV network caused by high-resistance and low energy efficient coax & electricity cables.
5
Power Booster – the 4G Transmission New Power Booster 4G
Integrated Dual Power inserter. Stand alone unit. RF PASS 1GHZ
Voltage gain 1: 1.56 enabling up to double powering distance. coverage area
Zero crossing - Smooth transition between conversion levels. Technology
4 Automatic gears AC/AC transformation gears
100 mA (EU model) 200 mA (US model) Self current load
Tel +972-544311933 / Fax +972-9-7968033 / Habustan st (PO 132) / Israe l 40691/ E-mai l [email protected]
6
• All in One two-way RF Pass 1GHZ passive device that “toggle” available power between two distant locations.• Redirecting power from the "normally" remote powered area to the area subject to power outage.• During the normal mode of operation, when there is no power outage at either end of the pair, the SYNERGY-2 act as power block to the other side. • Utilizing breakthrough step-up & stabilizing voltage technology the unit provides optimal & stable voltage level from local or remote P.S even from very long distance or using a un-stabilized P.S.
Tel +972-544311933 / Fax +972-9-7968033 / Habustan st (PO 132) / Israe l 40691/ E-mai l [email protected]
=DPS V 4 Power Booster
SYNERGY-2US PATENT 8,415,822
AC 1 input .AC 2 input Local output to local Optical Node.(AC+RF)
Backup IN.OUT (AC+RF to remote Node/ amp) 12
34
Power +
Signal
To remote / Node / Amplifier
Optical Node/Trunk
amp
P.S
21
3 4
+
7
Inputs/ Outputs configuration
Tel +972-544311933 / Fax +972-9-7968033 / Habustan st (PO 132) / Israe l 40691/ E-mai l [email protected]
Monitoring Inputs/outputs
ONLINE Current & Voltage +
status .
AC 2 - Input AC1 - Input
RF / AC 5-1000MHz 15A OUTPUT To Local Amplifier / Node
RF / AC 5-1000Mhz 15AINPUT / OUTPUTTo / From Remote Amplifier / Node
US PATENT 8,415,822
Vin 30-87V Vac (US)Vin 30-64V Vac (EU)
t
v
tv
Vout 87 Vac (US)Vout 60 Vac (EU)
• Inside view : SYNERGY-2 60/87V -2x15A
8
SYNERGY 2 the New generation.
Previous generations of DPS DPS Ver 4 SYNERGY-2
Limited by cable conductivity and Voltage drop.
External Power Booster required depend on voltage level when using remote powering.
Improved – Integrated power Booster (ALL in ONE). Remote backup powering
Required stabilizing P.S. (Ferro or T-former)
Required stabilizing P.S. (Ferro or T-former)
Improved .No required stabilizing P.S. Build in online zero crossing voltage stabilizer.
Stabilizing Voltage
External Dual power Inserter is needed Integrated Dual Power inserter. Integrated Dual Power inserter. Power Insertion
Required Two units. One unit. (+ optional Power Booster) One unit. Installation
--- Direct Monitoring outputs Via one Cable to IP transponders.
Direct Monitoring outputs Via one Cable to IP transponders. Monitoring
Tel +972-544311933 / Fax +972-9-7968033 / Habustan st (PO 132) / Israe l 40691/ E-mai l [email protected]
9 Tel +972-544311933 / Fax +972-9-7968033 / Habustan st (PO 132) / Israe l 40691/ E-mai l [email protected]
US PATENT 8,415,822Dual Port P.S + Docsis / EuroDOCSIS monitoring
NEW UR – Ultra Range +/- 25% Vin
Power Innovation
aa aaa
a
10 Tel +972-544311933 / Fax +972-9-7968033 / Habustan st (PO 132) / Israe l 40691/ E-mai l [email protected]
DOCSIS® & EuroDOCSIS Status Monitoring Embedded Transponder.
Direct RF connection to CATV network
Output 260,66,72 15A
Output 160,66,72 15A
External Monitoring DPS, SYNERGY-2 & more
Dual Port P.S model SC-D-TFPS-1800-E-O-M2 ports X 15A 60,66,72Vac 50/60 Hz .
Direct connection .
Direct connection .
Voltage testing points
Current loop testing points
(For Clamp meter )
11
SYNERGY-2 Typical configuration Optical node + Trunk amplifier(or second optical node) .
Power + Signal
From Optical node 4
21
3
1234
AC 2 input .AC 2 input
Local output to local Optical Node.(AC+RF)Backup IN.OUT (AC+RF to remote Node/ amp)
Power + Signal
Optical Node21
3 4To remote / amplifier / Node P.S
.S
P.S
60V
60V
Trunk amplifierOr Optical Node
60V60V
Area A
Area B
Tel +972-544311933 / Fax +972-9-7968033 / Habustan st (PO 132) / Israe l 40691/ E-mai l [email protected]
12 Tel +972-544311933 / Fax +972-9-7968033 / Habustan st (PO 132) / Israe l 40691/ E-mai l [email protected]
From Optical node
1234
AC 2 input .AC 2 input
Local output to local Optical Node.(AC+RF)Backup IN.OUT (AC+RF to remote Node/ amp)
Power + Signal
Optical Node21
3 4To remote / amplifier / Node P.S
.S
P.S
SYNERGY-2 – Demo backup power from Area A to Area B
Power + Signal Trunk amplifierOr Optical Node
60V55V50V
45V60V
Area A
Area B
21
43340V 60V
60V40V
13
Power + Signal
To Optical node4
21
3
1234
AC 2 input .AC 2 input
Local output to local Optical Node.(AC+RF)Backup IN.OUT (AC+RF to remote Node/ amp)
Power + Signal
21
3 4From remote amplifier / Node
P.S.S
P.S
Optical Node
45V50V
55V
60V 60VTrunk amplifierOr Optical Node
SYNERGY-2 – Demo backup power from Area B to Area A
P.S
Area A
Area B
Tel +972-544311933 / Fax +972-9-7968033 / Habustan st (PO 132) / Israe l 40691/ E-mai l [email protected]
40V 60V
40V 60V
14
SAFECOM’s powering system around the worldReliability since 1994
Tel +972-544311933 / Fax +972-9-7968033 / Habustan st (PO 132) / Israe l 40691/ E-mai l [email protected]
15
Power backup Comparisons
Synergy-2 / DPS V4
Generators Non Standby
Standby + Batteries
Power Type
Low High Low High Cost
Zero Permanent Negligible
Permanent Maintenance
Unlimited Limited by fuel
None 2 to 3 hour(Depends on
batt. condition )
Backup Power
Low cost Very expensive
Low Very Expensive
Redundant/ Diversity
Tel +972-544311933 / Fax +972-9-7968033 / Habustan st (PO 132) / Israe l 40691/ E-mai l [email protected]
16
Typical optical network powering examples
Tel +972-544311933 / Fax +972-9-7968033 / Habustan st (PO 132) / Israe l 40691/ E-mai l [email protected]
17
90V-network60V-available
Tel +972-544311933 / Fax +972-9-7968033 / Habustan st (PO 132) / Israe l 40691/ E-mai l [email protected]
18
60V-network90V-available
Tel +972-544311933 / Fax +972-9-7968033 / Habustan st (PO 132) / Israe l 40691/ E-mai l [email protected]
19 Tel +972-544311933 / Fax +972-9-7968033 / Habustan st (PO 132) / Israe l 40691/ E-mai l [email protected]
60V-network90V-available
HFC NetworkDPS4 power backup
20
Business case. Improving customer service and satisfaction. Enabling MSO to add new services that required top high
reliability. Unlimited backup time. Reducing dramatically CAPEX & OPEX. Increasing powering efficacy & save energy.
Tel +972-544311933 / Fax +972-9-7968033 / Habustan st (PO 132) / Israe l 40691/ E-mai l [email protected]
21 Tel +972-544311933 / Fax +972-9-7968033 / Habustan st (PO 132) / Israe l 40691/ E-mai l [email protected]
Complete Tree-View Import using CSV file• Also can discover One node at a time from the UI (on –demand discovery )• Network discovery• Export the Tree-View for further Use
1. Discovery can be backed up2. Automated Full Topology DPS/ SYNERGY back up
Auto Discovery of the PS Monitor• Supports any device that has a SCTE-HMS-PS-MIB• Supports auto discovery of thresholds (SCTE-HMS-COMMON-MIB )• Auto Generates Attribute Widgets with properly formatted thresholds• Supports all Adjacent devices like APC, Cordex Controllers etc.• Supports Discrete Thresholds
DOCSIS® & EuroDOCSIS Status Monitoring
22
• Monitors the Attributes – Pre-Configured Poll Interval– Summarization ( Hourly , Daily )– Graphing ( Single or Multiple attributes )– Attribute Refresh ( on demand )
• Monitors the Current Alarm Table– Generates the Events from this table– Auto Correlation ( If the alarm is pre-existing, does not generate a new
Alarm)– Updates the Tree-view with corresponding Severity – If SNMP Traps are enabled, It will auto-correlate the incoming traps with
Current Alarm table
23 Tel +972-544311933 / Fax +972-9-7968033 / Habustan st (PO 132) / Israe l 40691/ E-mai l [email protected]
Google Maps Integration
24
ON-LINE REPORT
25 Tel +972-544311933 / Fax +972-9-7968033 / Habustan st (PO 132) / Israe l 40691/ E-mai l [email protected]
Europe 60V & US 90V Standard. Support full 15A rms input /output. Prefect voltage at the remote location in the network. Water-proof Enclosure.(IPX8)�� Opposite connection protected. Input & Output Surge Protection.�� DOCSIS® & EuroDOCSIS Status Monitoring. Online RF transmission during operation.
(INTERNET,VOD,VOIP)
Standard Features
Power Innovation
26
Summery SAFECOM SYNERGY-2 & DPSv4 offers CATV operators the most efficient and
reliable complete backup solution for unlimited time at minimum cost. No additional cost for MSO further to the fact that SYNERGY-2 / DPS v4 unit
can be reuse from HFC network to full optical network. Following the government regulation for full powering backup. SYNERGY-2 ,DPSv4 & Power Booster systems enabling additional backup from
remote powering. No maintenance. Unlimited life time. Two way powering on a single cable (Coax or electrical cable) Full DOCSIS® & EuroDOCSIS Status Monitoring
Tel +972-544311933 / Fax +972-9-7968033 / Habustan st (PO 132) / Israe l 40691/ E-mai l [email protected]
27
Thank you