ECOFLOOR
TRAINING
HEATING CABLE TYPES
SINGLE-CORD CABLES*: DOUBLE-CORD CABLES**:
- SCREEN PROTECTION:
- WITHOUT SCREEN PROTECTION:
- SCREEN PROTECTION:
ASL1P
MPSV
PSV
PV
ADSV
ADPSP
MADPSP
* 2 x cold connection leads ** Only 1 x cold connection lead
HEATING CABLE TYPES
ADSV:
1 - DOUBLE-CORD CABLE
2 – FULL SCREEN PROTECTION (14 tinned copper wires 0,3 mm + AlPET foil) 3 - FEP INSULATION
4 - PVC JACKET
EL.CONNECTION:
1 x 3m COLD CONNECTION LEAD
1
1
2
3
4
ADSV USING - RECOMMENDATION
DIRECT HEATING (UNDER TILES):
WET/NOT WET AREAS (BATHROOMS, KITCHENS, HALLS, ETC..):
JUST INDOOR APPLICATION
NEW BUILDINGRECONSTRUCTION
ADSV STANDARD PRODUCTS
1.HEATING CABLES ADSV / ADSV-T ON DRUMS (SEMI-FINISHED PRODUCTS)
2.HEATING CABLE CIRCUITS (heating cable ADSV with 1connection lead)
ADSV STANDARD PRODUCTS
3.HEATING MATS
Double-sided adhesive tape
LDTS
ADSV (ADSV-T) STANDARD PRODUCTS
HEATING MATS LDTSPacking
Mat in carton box
ADSV (ADSV-T) STANDARD PRODUCTS
SELF-ADHESIVE MATS LSDTS Packing
Mat in carton box
ADSV STANDARD PRODUCTS
4.INSTALLATION SETS
ECOFLOOR Cable Kit
ADSV (ADSV-T) STANDARD PRODUCTS
INSTALLATION SETS
ECOFLOOR Comfort Mat
DIA (mm): 3,6-4,6
MIN. CABLE LOOPS SPACING (mm): 40
MAX.LINEAR POWER (W/m): 18
IN CASE OF SURFACE POWER HIGHER THAN 160W/m2 IS NECESSARY TO SET FOLLOWING MAX.FLOOR PROBE TEMP.(°C):
35
MAX.CABLE JACKET TEMP.(°C): 80
MAX. FIRST CABLE INSULATION TEMP.(°C): 120
ADSVTECHNICAL DATA
ADSV
ADSVPRODUCT RANGES
ADSV (ADSV-T*)
PRODUCTS MARKING STANDARD OFFER
STANDARD APPLICATION
Linear
Power
W/m
Surface
Power W/m2
Direct
Heating
Storage
Heating
Cable circuit ADSV10x
ADSV15x
ADSV18x
10
15
18
X
Mat LDTS8x-105*
LDTS12x-165*
100
160
X
Installation
Set
E.CableKit
E.ComfortMat*
10
160, 100
X
X
Heating cable circuits ADSV
INSTALLATION FOR DIRECT FLOOR HEATING
ECOFLOOR
Packing Variant
EHC Box
DIRECT FLOOR HEATING
NEW BUILDING
RECONSTRUCTION
Prevents heat losses to the sub-floor – recommendation during floor reconstruction!
F-BOARD
ADSV Heating cable circuit (double conductor with 1 connection lead „cold tail“
1. Control measuring
2. Grooving for thermostat floor
probe
3. Floor base cleaning and penetration
4. Floor probe installation
5. Fixing of el. junction
6. Installation of Heating cable circuit
7. Control measuring
8. Thin layer flexible cementing (glueing)
9. New tiling
Heating cable fixing accessories:
A. Cable fixing on concrete base floor
GRUFAST Fixing strip
ADHESIVE TAPE
B. Cable fixing on previous tiles floor (Reconstruction)
Measure total area to be heated, then order kit
Remember
Always keep cable at least 50mm away from wall
Use the spacing template provided in the kit to mark out the floor
0.5 m²
4 m² .25 m²
Bathroom area to be heated is 4.75 m², heated at 160 watts /m²
Kit 10 – 750 required (covers 4.7 m²)
Total area is: 4.75 m²
ECOFLOOR Cable Kit installation
Cut the groove for the floor probe and install the flexible pipe
Begin laying the cable taping it to the floor as you go
Test the cable for resistance and then cover with tile adhesive
Test the cable for resistance once tiling is complete
Tile and grout
ECOFLOOR Cable Kit installation
Heating mat LDTS
INSTALLATION FOR DIRECT FLOOR HEATING
ECOFLOOR
LDTS Heating mat (double conductor with 1 connection lead „cold tail“
1. Control measuring
2. Grooving for thermostat floor
probe
3. Floor base cleaning and penetration
4. Floor probe installation
5. Heating mat laying
6. Mat sticking to the floor base by its self-
adhesive tape
7. Control measuring
8. Thin layer flexible cementing (glueing)
9. New tiling
6. Heating mat installation
ECOFLOOR Comfort Mat
LDTS mat handling
INSTALLATION NOTICE
minimum distance of floor heating system from walls and fixtures like bath, shower or toilet is 5 cm.
the heating cable may never be shortened or
cutted !!! (only the cold connection
lead)
NO!
INSTALLATION NOTICE
• Heating cables must not be crossed and must not be intersected each other. Minimum distance between heating cables is 3 cm
the connector (junction) between the cold connection and heating cable needs to be install in straight stretcht (never be installed at a bend!)
the heating cable may never pass over an expansion joint
For floor heating are suitable following thermostats:
TH 132-AF
Eberle FR-E 52531
Eberle Instat 8
TEMPERATURE CONTROLS
Fenix Therm 100
16 Amps thermostat connection (thermostat with floor probe)
L – phase (el.supply)
N – neutral (el.supply)
L’ –phase (Ecofloor)
N’ – neutral (Ecofloor)
Electrical installation directly throught the thermostat
Electrical installation throught the el.box and contactor(1 thermostat controls 2 Ecofloor units (cables/mats) through the contactor to prevent thermostat switch current overloading)
HEATING CABLE TYPES
ADPSP:
1 - DOUBLE-CORD CABLE2 - FEP INSULATION
4 - FULL SCREEN PROTECTION (PET/AL foil + copper wires)
3 - XLPE INSULATION
EL.CONNECTION:
1 x 5m COLD CONNECTION LEAD
5 – PVC jacket (UV protection)
2
5
1
34
4 1
ADPSP USING - RECOMMENDATION
REMOVING ICE AND SNOW FROM ROOFS AND
GUTTERS
AS A PROTECTION OF PIPES AGAINST FREEZING
JUST OUTDOOR APPLICATION
ADPSP
STANDARD PRODUCTS
1.HEATING CABLES ADPSP (HALF-FINISHED PRODUCTS)
2.HEATING CABLE CIRCUITS (heating cable ADPSP with 1connection lead)
ADPSP ECOFLOOR Heating Cable
DIA (mm): 5,0-5,9
MIN. CABLE LOOPS SPACING (mm): 40
MAX.LINEAR POWER (W/m): For roofs and gutters
For pipes
Technologic heating
20
10
15
MAX.CABLE JACKET TEMP.(°C): 80
MAX. FIRST CABLE INSULATION TEMP.(°C): 120
ADPSPTECHNICAL DATA
ADPSP
ADPSPPRODUCT OFFER
ADPSP
PRODUCTS MARKING STANDARD OFFER
STANDARD APPLICATION
Linear
Power
W/m
Surface
Power W/m2
Roofs and
gutters
Protection of
pipes
Cable circuit ADPSP 10x
ADPSP 20x
10
20
X
X
Mat
Installation
Set
TEMPERATURE CONTROLS
Eberle EM 52487Snow and ice sensor ESD 524003Heat sensor ESD 524004
Heating of eaves troughs and gutters
Heating of pipes and tubes
Eberle ITR-3 UTR/60
sensors
ANOTHER ECOFLOOR
APPLICATIONS
INDOOR APPLICATION
SEMI-STORAGE AND STORAGE HEATING:
WET AREAS (BATHROOMS, LAUNDRIES, ETC..):
NOT WET AREAS (KITCHENS, HALLS, LIVING ROOMS, ETC..):
PSV
PV
MPSV
MADPSP
OUTDOOR APPLICATION
OUTDOOR SURFACE WARMING
MPSV
MADPSP
SPECIAL APPLICATION
GRASS WARMING ON FOOTBALL STADIUM
MADPSP
Contact us : FENIX Trading s.r.o.
Slezska 2
79001 Jesenik, Czech Rep.
Tel/Fax: +420 584 495 304/303
E-mail: [email protected]