www.ipcopower.com
www.ngrp.com/nl/our-business/ecoscrub-solutions
IPCO Power provides worldwide solutions and
specialist services in the field of environment to assist
petrochemical companies to create sustainable
production activities.
IPCO Power has a strategic co-operation with the Nature group
in the development of the E.S.U.
Exxon Mobile 2003
Dow Chemical 2003
History
Development
Development and Goals
• Wet scrubber
• Selection of additives
• B.A.T. Status
• Low energy consumption
• Low resource consumption
• Robust process
• Easy control
• Product recovery
In co-operation with DCMR (Dutch Environmental Authorities)
Product separation
Cyclone drain Skim tank
Result of HFO
Separation results
Cyclone (1) Main tank (3) Skim tank (2)
Result of HFO
Endurance test - 75 hours
Result of HFO
Endurance test - 75 hours
Progress VOC concentration IN/OUT during endurance test
VO
C c
oncentr
ation
[ m
g/m
3]
VOC IN lab sample
VOC OUT lab sample
Average OUT
Average IN
VOC IN continuous
VOC OUT continuous
Result of HFO
Best Available Technology status
Performances
• ≥ 90 % odor reduction
• ≥ 80 % Total Organic Compounds reduction
• 0 % on soap solutions
• Water consumption 80 - 150 ltr / hour
• Electricity consumption 400 Volt/64 ampere
• Processing capacity 3600 m3/hour
• Max inlet temperature 180o C.
• Remote control & guidance
Efficiency / I.R. LEL measurement
Test for Shell with Pyrolyse gas vapour
Fixed Ecoscrub STR – polluted – 23-05-2011
Con
ce
ntr
atio
n T
OC
[ m
g/m
3 ]
Fixed Ecoscrub STR – cleaned – 23-05-2011
Con
ce
ntr
atio
n T
OC
[ m
g/m
3 ]
Date : Mai 23th 2011
Time range : 10:40 until 18:20 (7 hours & 40 minutes)
Average VOC concentration before test: 75.730 mg/m3
Average VOC concentration after test : 9.083 mg/m3
Average removal efficiency on VOC
during entire measurement period: 88%
Washing additives
• Envirosorb & EnviroPlus
o Bio-degradable, non emitting
o MSDS available
Both products are tested and approved by the
Dutch National Institute for Safety and Environment (RIVM)
Application area
100
10
1
Con
ce
ntr
atio
n (
gr/
m3)
Odor and emission control treatment system overview
0 10 100 1.000 20.000 100.000
Flow rate (m3/hr)
Scrubber Cryogenic
condensation
Regenerative
adsorption
Thermic/catalyc
combustion
Rotating
adsorption
Condensation
Bio filter
Adsorption (non regenerative)
Ecoscrub
Some experiences
• Service Terminal Rotterdam; Fixed unit for HFO VOC/Odor control
• Dupont de Nemours; Vapour handling of Teflon powder drying (150oC)
• Vopak; VOC/Odor control during tank cleaning and vapour handling of fuel
tanks
• Eastman Chemicals; VOC/Odor control during tank cleaning
• Odfjell Tank Terminals; VOC/Odor control during tank cleaning and vapour
handling of fuel tanks
• Akzo Nobel; Failure own scrubber
• Organik Kimya; Maintenance own scrubber
Fixed installation STR Rotterdam
Fixed installation STR Rotterdam
Dupont de Nemours
Mobile unit
Control & dosing unit
Mobile unit
Applications
• Volatile Organic Compounds
• Odor
• Hydrocarbons - Chemicals
• Dust
• Powders
What do we offer
Mobile system; quick deployment for rental and testing
Fixed system; Robust & efficient solution
• B.A.T. solution for effective Vapour/Odor control
o especially for products with a vapour pressure <100 mB
• VOC emission reduction of ≥ 80%
• Odor emission reduction of ≥ 90% (such as Mercaptane & H2S)
• Mobile unit for testing and rental purposes o Testing reports are provided
• Customized engineered fixed unit, based on testing reports
• Turnkey projects