6
Floor Standing FV SeriesFloor Standing FV Series
DealerLot 60334, Persiaran Bukit Rahman Putra 3,Taman Perindustrian Bukit Rahman Putra,47000 Sungai Buloh, Selangor Darul Ehsan, Malaysia
http://www.daikin.com/global_ac/
All rights reservedcSpecifications, designs and other content appearing in this brochure are current as of April 2015 but subject to change without notice.
PLXSPH1502
COOLING ONLY [60Hz]
Floor Standing
Features
Highlights• Left and right auto swing to cool the corners of the room
• Turbo activation in Cool mode• Auto random restart with last state memory• Timer setting from wireless controller• Removable washable saranet filter• Cache at intake grille for safety during filter removal• Self diagnosis for faults detection and indication
Auto horizontal swing
Space saving with style and functionality.
FeaturesAn ideal way of space saving with style and functionality, with it’s ease of installation, it is suitedto be installed in offices, commercial shops, restaurants, showrooms and mosques.
Manual setting of vertical airflow louvers
• Capacity range from 7.8kW to 16.1kW• Wireless controller BRC52A62 (cooling only) is supplied as
standard• Utilize common outdoor - keep one outdoor stock for use
with other light commercial models such as ceiling cas-settes, and ceiling concealed models
• Large buttons on control panel for ease of use• Error code display on the seven-segment of the control
panel by blinking• Keylock for prevention of setting change by unauthorized
personnel• Space in the unit below the fan able to accommodate drain
pump, depending on drain pump size (drain pump is optional, separately purchased and field installed)
• Sleek, stylish and modern to blend into any environment• High gloss finishing for easy cleaning• Slim profile• Stylish black control panel with white LED light for crisp
clear display
21
Fea
High
• Ca• Wi
sta• Uti
witset
• Lar• Err
pa• Ke
pe• Sp
puopt
• Sle• Hig• Slim• Sty
cle
Off State On State
Compact & Easy-to-Use Handset
BRC52A62 (cooling only) KEY LOCK Function :Activation and deactivation of keylock by pressing “SWING” and “TURBO” together for 5 seconds
White display lights up to indicate modes and temperature setting when switched on
Floor standing control panel
KEY LOCK icon displayed when activated
FeaturesThe floor standing unit can be controlled by using two methods, i) settings by pressing the control panel on the unitii) settings by using the wireless controller (wireless controller comes as standard)
A stylish black control panel with white LED light for crisp clear display.
The floor standing unit is incorporated withIR sensor for usage with wireless controller
(wireless controller comes as standard)
BRC52A62 (cooling only)
• Prominent 40mm LCD display
• “Glow in the dark” ON/OFF button
• Real time clock display• Dedicated button for Turbo
function
Th fl t di it i i t
43
6
Location of condensate water drain pump
* Condensate water drain pump is optional, separately purchased and field installed
Removable washable saranet filter
Safety cache during removal offilter for prevention of access to electrical and mechanical parts
Grille profile for slimmer outlook
Stylish profile with classy control panel
Optional plasma active IAQ(Indoor Air Quality)
Floor standing air flowThe floor standing is able to achieve air flow distance up to 25m*.
* Note: Based on 16.1kW model
Floor Standing Features
Turbo modeTurbo function is available in Cool mode. Once it is activated, the floor standing will run on full power with the indoor fan running at maximum speed for 20 minutes. This enables the set temperature to be achieved faster.
T set
T room
Start 20min 30min
Auto random restart with Last-State-MemoryIn the event of a sudden power failure during operation, the floor standing restarts automatically in 64 different recovery timing patterns (within 180 seconds to 244 seconds) and it will operate based on the previous settings (operating mode, temperature setting and fan speed). This ensures that air conditioners in the same building resume randomly instead of all units resuming at the same time, preventing power surge after a blackout.
Power Failure Power Returns
E 2 PROM
OperationStop
Restart
Setting stored before power failure.
Condensate water drain pump
Floor Standing UnitPiping
25m
5
7 8
Floor Standing A Series (60Hz)
With wireless controller
CONTROLLER
Power from indoor
Power from outdoor
POWER SUPPLY
Selectable fan speed - different fan speed isavailable for comfort selection
Manual vertical swing - Adjustable verticaldischarge grille for desired air flow direction
Automatic horizontal air flow - automatic movement of air discharge louver for uniformair distribution
AIR FLOW
4-Way air discharge
Standard FeaturesCOMFORT
Dry mode - keeping the room dehumidified,while maintaining room temperature
Turbo mode - rapid cooling with highestfan speed for immediate comfort
FIN TYPEAnti corrosion hydrophilic gold finGOLD
Plasma
IAQWashable saranet filter - removal of airborne dust particles through saranet filter ensures cleaner air supply › Left and right auto swing
› Keylock function› Easy maintenance› Stylish panel › Turbo mode› Gold fin for outdoor› Wireless handset BRC52A62 (C/O) supplied as standard
FV30AXVL FV40AXVL FV60AXVL
R30CGXVL9 R40DGXVL9 R60DGXTL9
Btu/h 26500 36000 55000W 7770 10550 16120
W/W 2.59 2.63 2.64Power Supply V/Ø/Hz 220/1/60 220/1/60 220/1/60Air Flow CFM 675 1035 1170Sound Pressure Level dBA 44 49 54Height mm 1850 1850 1850Width mm 600 600 600Depth mm 270 350 350Net Weight kg 42 45 51
Sound Pressure Level dBA 57 61 66Height mm 756 852 852Width mm 855 1030 1030Depth mm 328 400 400Net Weight kg 61 81 104Pipe Connection - Liquid mm 9.52 9.52 12.70Pipe Connection - Gas mm 15.88 19.05 19.05
Indo
orO
utdo
or
Indoor Model Name
Outdoor Model Name
Nominal Cooling Capacity
Nominal EER
Max. Piping LengthMax. Elevation
mm
4025
4025
4525
FV30/40/50/60AXVL R40/50/60DGXVL9
Specification for Floor Standing - Cooling (R22)
FV50AXVL
R50DGXTL9
47500139202.78
220/1/60103550
185060035048
66852
103040095
9.5219.05
4525
* Optional
GOLD*
** R30/40DGXVL9R50/60DGXTL9
AL**
Power Supply V/Ø/Hz 220/1/60 220/1/60 220/3/60220/3/60
R30CGXVL9
9 10